Gutter-Flashing-Model.pdf

PDF 137 KB Posted

Attached to
High School Roof Replacement
Solicitation number
RFP MASO 260000002613 2
Issued by
Genesee County, Edmore Village, Michigan

About this file

This is a technical drawing specification document for gutter flashing installation details. The document, designated as Drawing No. 53 and created in 2023, provides architectural and construction specifications for a gutter flashing system without identified agency or jurisdiction involvement in this particular file.

The drawing illustrates a comprehensive gutter flashing assembly that includes Tremply Kee membrane material hot air welded to a metal gutter, with insulation attached per specification requirements. The installation specifications detail fastening requirements using galvanized annular ring shank nails at 6-inch on-center spacing for the membrane and 3-inch on-center spacing for wood blocking attached at 250 pounds force per foot. The assembly incorporates a continuous galvanized metal cleat joint treatment at the edge, a 4-inch minimum metal flashing strip with 1/4-inch spacing, and a 4-inch wide aluminum tape flashing strip heat-welded in place. The drawing is presented at a not-to-scale (NTS) ratio and serves as a standard detail reference for gutter flashing construction. No pricing, bidding timeline, contract duration, or procurement-related information is contained within this technical specification document.

View the file

Other files

File Type Posted
Mason High School- AOC.pdf PDF
~WRL0001.tmp —
Mason High School Summer of 2027 Roofing Scope of Work.docx DOCX document
2-Piece-Shop-Fabricated-Metal-Edge-Flashing-Model.pdf PDF
Typical-Edge-Flashing-Model.pdf PDF
Curb-for-Air-Handling-Unit.pdf PDF
Plumbing-Vent-Model.pdf PDF
Hot-Stack-Penetration.pdf PDF
Gauge-or-Thickness-Guide.pdf PDF
Dail-Water-Stop-Tie-In-Model.pdf PDF
AFFIDAVIT OF COMPLIANCE IRAN.docx DOCX document
Mason Middle School- Alternate AOC.pdf PDF
Addendum #1.pdf PDF
Mason High School Summer of 2027 Roofing Bid Form.doc DOC document
Project-Mason High School THERMastic 80 Roofing Replacements.pdf PDF
Roof-Drain-with-Gravel-Guard.pdf PDF
Wood-Curb-Model.pdf PDF
Roof-Hatch-Model.pdf PDF
Conduit-or-Piping-Support.pdf PDF
Slip-Metal-Skirt-Flashing.pdf PDF
Light-Metal-Parapet-Cap.pdf PDF
Pitch-Pocket-with-Grout.pdf PDF
Typical-Covers-at-Membrane-T-Laps-Model.pdf PDF
TremPly-KEE-at-Fascia-System-Raised-Cant-Edge-Model.pdf PDF
Field-Fabricated-Pipe-Flashing-Model.pdf PDF
Roof-System-Attachment-Slope,-Transition,-Change-in-Plane.pdf PDF
TLRFIA-over-Steel-Model.pdf PDF
Piping-Through-Roof-Deck.pdf PDF
Notice To Bidders Mason High School Summer of 2027.docx DOCX document
Familial Relationship Disclosure.docx DOCX document
Composite-Roof-System-Cross-Section-Adhered-ISO-Hot-Model.pdf PDF
Pre-Molded-Pipe-Flashing-Model.pdf PDF
Door-Threshold-Model.pdf PDF
Equipment-Stand-Rain-Collar.pdf PDF
Flashing-for-Non-Wall-Supported (1).pdf PDF
Metal-Sleeve-and-Storm-Collar.pdf PDF
Metal-Flashing,-Round-to-Square.pdf PDF
Base-Sheet-Fastener-7-Inch.pdf PDF
Roof 13 to 15 Detail.pdf PDF
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INSULATION ATTACHED PER

SPECIFICATION REQUIREMENTS

TREMPLY KEE MEMBRANE

HOT AIR WELD

TREMPLY KEE MEMBRANE FLASHING STRIP

GALVANIZED ANNULAR RING

SHANK NAILS (6" O.C.)

TREMCO METAL

HOT AIR WELD

METAL GUTTER (BY OTHERS)

WOOD BLOCKING

ATTACHED @ 250 LBF/FT

FASTEN WITH GALVANIZED ANNULAR

RING SHANK NAILS (3" O.C.)

CONTINUOUS GALVANIZED METAL CLEAT

JOINT TREATMENT AT EDGE METAL

4" MIN.

1/4" 2"

4"

TREMCO METAL

2" WIDE

OVER JOINT

1/4" GAP

ALUMINUM TAPE

4" WIDE FLASHING STRIP,

HEAT WELDED IN PLACE

TREMPLY KEE MEMBRANE EDGE FLASHING STRIP

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

GUTTER FLASHING

DWG NO. 53

Sheets and Views
Model