Curb-for-Air-Handling-Unit.pdf
PDF 140 KB Posted
- Attached to
- High School Roof Replacement
- Solicitation number
- RFP MASO 260000002613 2
- Issued by
- Genesee County, Edmore Village, Michigan
About this file
This is a technical drawing specification document for a curb-for-air-handling-unit installation, though the specific contracting agency or jurisdiction is not identified in the provided content. The drawing details the construction specifications for a built-up roofing (BUR) hot/cold base flashing curb designed to accommodate air handling units on roofed structures. The technical specifications include requirements for sealant tape, a 16-gauge minimum frame, wood curb construction, fasteners positioned at 8-inch on-center spacing with 18-inch on-center counterflashing, two-ply stripping with specified base flashing adhered to the roof deck, gravel surfacing, and insulation materials. An alternate frame location is noted for heavy-unit installations, with gasketed fasteners required at a minimum of two per side. The drawing is presented at a not-to-scale (NTS) format and references various specified materials and components throughout the design.
No pricing terms, contract timelines, response dates, bid due dates, site visit information, bidders' conferences, award dates, contract terms, renewal options, set-asides, incumbent information, or funding details are provided in this technical drawing document. The file functions primarily as a design specification and does not contain typical contract opportunity information such as procurement timelines or financial requirements.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DWG NO. 03
BUILT-UP ROOFING
HOT/COLD BASE FLASHING
CURB FOR AIR HANDLING UNIT
SPECIFIED
SEALANT TAPE AS
16 GA. MIN. FRAME
WOOD CURB
FASTENER 8'' O.C.
FASTENED 18'' O.C.
COUNTERFLASHING
SPECIFED BASE
FLASHING ADHERED
TWO-PLY STRIPPING
GRAVEL SURFACING
SPECIFIED BUR
INSULATION
ALTERNATE FRAME
LOCATION FOR
HEAVY UNITS
ROOF DECK AS SPECIFIED
WITH GASKETED
FASTENERS MINIMUM
TWO PER SIDE
SPECIFED BASE
SPECIFIED CANT
MEMBRANE
SHEET TITLE:
DRAWING No.:
SCALE:
NTS
AutoCAD SHX Text
8'' MIN.
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .