This is a technical drawing specification document for typical edge flashing installation, prepared in 2023 by Tremco Metal (Drawing No. 114, not to scale). The document provides detailed specifications for membrane edge flashing assembly, including materials, dimensions, and installation methods. Key components specified include Tremply Kee Membrane flashing strips, galvanized annular ring shank nails installed at 6-inch on-center spacing, hot air weld insulation attachment per specification requirements, wood blocking attached at 250 pounds-force per foot continuous, and galvanized metal cleats. The assembly incorporates butyl sealing tape (optional), ring shank nails at 3-inch on-center spacing, aluminum tape at 4-inch width, and heat-welded flashing strips. The specifications include precise measurements, including a 1/4-inch gap, 2-inch wide joint treatment dimensions, and 4-inch minimum flashing strip requirements, with joint treatment at edge metal specifications detailed in the technical drawing.
The document does not contain information regarding pricing terms, set-asides, incumbents, funding requirements, contract award dates, or other procurement-related details. This drawing serves as a technical reference and quality standard for roofing or building envelope flashing installation work, establishing construction methodology and material specifications for contractors or construction professionals executing edge flashing work.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TREMCO METAL
TREMPLY KEE MEMBRANE FLASHING STRIP
TREMPLY KEE MEMBRANE
GALVANIZED ANNULAR RING
SHANK NAILS (6" O.C.)
HOT AIR WELD
INSULATION ATTACHED PER
SPECIFICATION REQUIREMENTS
WOOD BLOCKING
ATTACHED @ 250 LBF/FT
CONTINUOUS GALVANIZED METAL CLEAT
BUTYL SEALING TAPE (OPTIONAL)
RING SHANK NAILS (3" O.C.)
FASTEN WITH GALVANIZED ANNULAR
JOINT TREATMENT AT EDGE METAL
4" MIN.
1/4" 2"
4"
TREMCO METAL
2" WIDE
OVER JOINT
1/4" GAP
ALUMINUM TAPE
4" WIDE FLASHING STRIP,
HEAT WELDED IN PLACE
TREMPLY KEE MEMBRANE EDGE FLASHING STRIP
SHEET TITLE:
DRAWING No.:
SCALE:
NTS
TYPICAL EDGE FLASHING
DWG NO. 114
| Sheets and Views |
| Model |