TremPly-KEE-at-Fascia-System-Raised-Cant-Edge-Model.pdf

PDF 118 KB Posted

Attached to
High School Roof Replacement
Solicitation number
RFP MASO 260000002613 1
Issued by
Genesee County, Edmore Village, Michigan

About this file

This is a technical specification drawing for a roofing edge system product called TremPly Kee at Fascia System with a raised cant edge design. The document provides detailed installation instructions and component specifications for the edge system, which includes a pre-manufactured assembly designed to be installed per manufacturer requirements and project specifications. The system is supplied in 12-foot lengths and includes optional fascia cover components. Key materials specified include TremPly Kee LV bonding adhesive, a chamfered 1" x 2" cant strip, TremPly Kee membrane, approved sealant, wood blocking, steel fasteners (12" on center spacing using #9 x 2" stainless steel fasteners provided by Tremco), butyl sealing tape, and an extruded anchor bar. The drawing is identified as DWG No. 104 and is drawn to a not-to-scale (NTS) basis as of 2023.

This is a manufacturer's technical drawing rather than a government contract solicitation document. It serves as a reference specification for construction or renovation projects requiring this specific roofing edge system installation. The document does not contain information regarding pricing, bid deadlines, site visits, bidder meetings, contract terms, or funding sources, as it is purely a technical specification sheet intended to guide proper installation of the TremPly Kee roofing system component.

View the file

Other files

File Type Posted
Roof-Hatch-Model.pdf PDF
Flashing-for-Non-Wall-Supported (1).pdf PDF
Typical-Covers-at-Membrane-T-Laps-Model.pdf PDF
Mason High School- AOC.pdf PDF
AFFIDAVIT OF COMPLIANCE IRAN.docx DOCX document
Dail-Water-Stop-Tie-In-Model.pdf PDF
Metal-Sleeve-and-Storm-Collar.pdf PDF
Slip-Metal-Skirt-Flashing.pdf PDF
Conduit-or-Piping-Support.pdf PDF
2-Piece-Shop-Fabricated-Metal-Edge-Flashing-Model.pdf PDF
Roof 13 to 15 Detail.pdf PDF
Field-Fabricated-Pipe-Flashing-Model.pdf PDF
TLRFIA-over-Steel-Model.pdf PDF
Pitch-Pocket-with-Grout.pdf PDF
Plumbing-Vent-Model.pdf PDF
Door-Threshold-Model.pdf PDF
Roof-System-Attachment-Slope,-Transition,-Change-in-Plane.pdf PDF
Project-Mason High School THERMastic 80 Roofing Replacements.pdf PDF
Gutter-Flashing-Model.pdf PDF
Hot-Stack-Penetration.pdf PDF
Wood-Curb-Model.pdf PDF
Piping-Through-Roof-Deck.pdf PDF
Metal-Flashing,-Round-to-Square.pdf PDF
~WRL0001.tmp —
Mason High School Summer of 2027 Roofing Bid Form.doc DOC document
Roof-Drain-with-Gravel-Guard.pdf PDF
Gauge-or-Thickness-Guide.pdf PDF
Equipment-Stand-Rain-Collar.pdf PDF
Curb-for-Air-Handling-Unit.pdf PDF
Base-Sheet-Fastener-7-Inch.pdf PDF
Composite-Roof-System-Cross-Section-Adhered-ISO-Hot-Model.pdf PDF
Pre-Molded-Pipe-Flashing-Model.pdf PDF
Mason Middle School- Alternate AOC.pdf PDF
Familial Relationship Disclosure.docx DOCX document
Light-Metal-Parapet-Cap.pdf PDF
Typical-Edge-Flashing-Model.pdf PDF
Mason High School Summer of 2027 Roofing Scope of Work.docx DOCX document
Notice To Bidders Mason High School Summer of 2027.docx DOCX document
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOTES

TREMPLY KEE LV BONDING ADHESIVE

"CHAMFERED" PT 1" X 2" CANT STRIP

TREMPLY KEE MEMBRANE

APPROVED SEALANT

WOOD BLOCKING

ATTACHED @ 250 LBF/FT

STEEL FASTENERS (12" O.C.)

#9 X 2" (50.8 mm) STAINLESS

(PROVIDED BY TREMCO)

BUTYL SEALING TAPE

EXTRUDED ANCHOR BAR

FASCIA COVER

(12'-0" LENGTHS)

(OPTIONAL)

1. INSTALL PRE-MANUFACTURED EDGE SYSTEM PER SPECIFICATIONS AND TREMPLY KEE'S INSTALLATION

REQUIREMENTS.

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

TREMPLY KEE AT FASCIA

SYSTEM (RAISED CANT EDGE)

DWG NO. 104

Sheets and Views
Model

File details come from the government source that posted it. Updated .