Plumbing-Vent-Model.pdf
PDF 155 KB Posted
- Attached to
- High School Roof Replacement
- Solicitation number
- RFP MASO 260000002613 1
- Issued by
- Genesee County, Edmore Village, Michigan
About this file
This is a technical drawing specification document for plumbing vent flashing installation, applicable to state and local construction projects. The document provides detailed specifications for soft metal flashings used in plumbing vent stack applications on built-up roofing systems. Sheet lead flashings must meet a minimum weight of 4 pounds per square foot, while sheet copper flashings must be minimum 16 ounces. The specification requires that copper flashing installed over iron or steel pipes be wrapped with asphalt-coated roofing felt to prevent galvanic corrosion between dissimilar metals. For plumbing vents with diameters less than 2 inches, soft metal caps rolled 1 inch down into the pipe are required. The flange assembly must be set in specified mastic with a minimum 4-inch flange, and the installation includes two target plies adhered to the specified built-up roofing membrane over specified insulation and roof deck materials.
The drawing specification addresses technical installation requirements for plumbing vent penetrations through built-up roofing systems, emphasizing material compatibility and proper sealing methods. The specification includes provisions for both hot and cold plumbing vent applications with detailed dimensional requirements and material selections designed to ensure weathertight performance and prevent water infiltration at roof penetrations. No pricing, contract terms, award dates, or bidding procedures are contained within this technical specification document.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DWG NO. 08
NOTES
SOFT METAL FLASHINGS
1. SHEET LEAD: MINIMUM 4 LB. (20kg²/m ) PER SQ.FT.
2. SHEET COPPER: MINIMUM 16 OZ. IF COPPER FLASHING IS INSTALLED OVER AN IRON OR STEEL PIPE, WRAP AN ASPHALT COATED ROOFING FELT TO PREVENT DIRECT CONTACT BETWEEN TWO DISSIMILAR
METALS.
BUILT-UP ROOFING HOT/COLD
PLUMBING VENT FLASHING
ROLLED SOFT METAL FLASHING
1'' DOWN INTO PIPE
STEEL SCREEN
OPTIONAL SOLDER STAINLESS:
PLUMBING VENT STACK
PLUMBING VENT STACK
SET FLANGE IN
SPECIFIED MASTIC
MASTIC SEAL
TWO TARGET PLIES ADHERED
SPECIFIED BUR MEMBRANE
SPECIFED INSULATION
ROOF DECK AS SPECIFIED
FOR PLUMBING VENTS WITH
DIAMETERS LESS THAN
2'' USE SOFT METAL CAPS
SOFT METAL CAP 1'' DOWN
INTO PIPE
IN SPECIFIED ADHESIVE
SHEET TITLE:
DRAWING No.:
SCALE:
NTS
AutoCAD SHX Text
4'' MIN. FLANGE
AutoCAD SHX Text
2'' MIN.
| Sheets and Views |
| Model |