Plumbing-Vent-Model.pdf

PDF 155 KB Posted

Attached to
High School Roof Replacement
Solicitation number
RFP MASO 260000002613 1
Issued by
Genesee County, Edmore Village, Michigan

About this file

This is a technical drawing specification document for plumbing vent flashing installation, applicable to state and local construction projects. The document provides detailed specifications for soft metal flashings used in plumbing vent stack applications on built-up roofing systems. Sheet lead flashings must meet a minimum weight of 4 pounds per square foot, while sheet copper flashings must be minimum 16 ounces. The specification requires that copper flashing installed over iron or steel pipes be wrapped with asphalt-coated roofing felt to prevent galvanic corrosion between dissimilar metals. For plumbing vents with diameters less than 2 inches, soft metal caps rolled 1 inch down into the pipe are required. The flange assembly must be set in specified mastic with a minimum 4-inch flange, and the installation includes two target plies adhered to the specified built-up roofing membrane over specified insulation and roof deck materials.

The drawing specification addresses technical installation requirements for plumbing vent penetrations through built-up roofing systems, emphasizing material compatibility and proper sealing methods. The specification includes provisions for both hot and cold plumbing vent applications with detailed dimensional requirements and material selections designed to ensure weathertight performance and prevent water infiltration at roof penetrations. No pricing, contract terms, award dates, or bidding procedures are contained within this technical specification document.

View the file

Other files

File Type Posted
Typical-Covers-at-Membrane-T-Laps-Model.pdf PDF
2-Piece-Shop-Fabricated-Metal-Edge-Flashing-Model.pdf PDF
Field-Fabricated-Pipe-Flashing-Model.pdf PDF
Curb-for-Air-Handling-Unit.pdf PDF
Wood-Curb-Model.pdf PDF
Base-Sheet-Fastener-7-Inch.pdf PDF
Roof 13 to 15 Detail.pdf PDF
Roof-System-Attachment-Slope,-Transition,-Change-in-Plane.pdf PDF
Gutter-Flashing-Model.pdf PDF
Roof-Drain-with-Gravel-Guard.pdf PDF
Hot-Stack-Penetration.pdf PDF
Door-Threshold-Model.pdf PDF
Flashing-for-Non-Wall-Supported (1).pdf PDF
Roof-Hatch-Model.pdf PDF
Metal-Sleeve-and-Storm-Collar.pdf PDF
Metal-Flashing,-Round-to-Square.pdf PDF
Piping-Through-Roof-Deck.pdf PDF
Mason Middle School- Alternate AOC.pdf PDF
Mason High School- AOC.pdf PDF
Mason High School Summer of 2027 Roofing Scope of Work.docx DOCX document
TremPly-KEE-at-Fascia-System-Raised-Cant-Edge-Model.pdf PDF
Composite-Roof-System-Cross-Section-Adhered-ISO-Hot-Model.pdf PDF
Pre-Molded-Pipe-Flashing-Model.pdf PDF
Typical-Edge-Flashing-Model.pdf PDF
Light-Metal-Parapet-Cap.pdf PDF
Notice To Bidders Mason High School Summer of 2027.docx DOCX document
AFFIDAVIT OF COMPLIANCE IRAN.docx DOCX document
Familial Relationship Disclosure.docx DOCX document
Mason High School Summer of 2027 Roofing Bid Form.doc DOC document
~WRL0001.tmp —
Project-Mason High School THERMastic 80 Roofing Replacements.pdf PDF
Equipment-Stand-Rain-Collar.pdf PDF
TLRFIA-over-Steel-Model.pdf PDF
Conduit-or-Piping-Support.pdf PDF
Gauge-or-Thickness-Guide.pdf PDF
Slip-Metal-Skirt-Flashing.pdf PDF
Dail-Water-Stop-Tie-In-Model.pdf PDF
Pitch-Pocket-with-Grout.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG NO. 08

NOTES

SOFT METAL FLASHINGS

1. SHEET LEAD: MINIMUM 4 LB. (20kg²/m ) PER SQ.FT.

2. SHEET COPPER: MINIMUM 16 OZ. IF COPPER FLASHING IS INSTALLED OVER AN IRON OR STEEL PIPE, WRAP AN ASPHALT COATED ROOFING FELT TO PREVENT DIRECT CONTACT BETWEEN TWO DISSIMILAR

METALS.

BUILT-UP ROOFING HOT/COLD

PLUMBING VENT FLASHING

ROLLED SOFT METAL FLASHING

1'' DOWN INTO PIPE

STEEL SCREEN

OPTIONAL SOLDER STAINLESS:

PLUMBING VENT STACK

PLUMBING VENT STACK

SET FLANGE IN

SPECIFIED MASTIC

MASTIC SEAL

TWO TARGET PLIES ADHERED

SPECIFIED BUR MEMBRANE

SPECIFED INSULATION

ROOF DECK AS SPECIFIED

FOR PLUMBING VENTS WITH

DIAMETERS LESS THAN

2'' USE SOFT METAL CAPS

SOFT METAL CAP 1'' DOWN

INTO PIPE

IN SPECIFIED ADHESIVE

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

AutoCAD SHX Text

4'' MIN. FLANGE