About this file
This is a technical drawing specification document for a built-up roof hot/cold wall flashing system designed for non-wall-supported deck applications. The drawing (DWG No. 11) details the roofing membrane configuration and flashing installation requirements, specifying a two-ply built-up roof (BUR) membrane with fasteners spaced at eight-inch on-center intervals. The system includes a one-piece counterflashing, specified sealant, and roof insulation installed over the specified roof deck with gravel surfacing. The design incorporates a flexible vapor retarder serving as an insulation retainer, wood nailers secured to the deck with staggered rows positioned twenty-four inches on-center, and stripping with specified base flashing installed at twelve-inch on-center intervals with staggered blocking and wood cant nailed to the sheet. The minimum measurement for the counterflashing is four inches.
The document provides construction detailing and material specifications essential for proper roof flashing installation and does not contain procurement information such as pricing, set-asides, award dates, contract terms, or response deadlines. This appears to be a technical reference drawing used to communicate roofing assembly requirements to contractors or construction professionals, with all dimensions and material specifications noted as either "specified" or "as specified," indicating that detailed requirements are provided in accompanying specification documents.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DWG NO. 11
BUILT-UP ROOF
HOT/COLD WALL FLASHING FOR
NON-WALL-SUPPORTED DECK
SPECIFIED BUR MEMBRANE
TWO-PLY
FASTENERS 8'' O.C.
ONE PIECE COUNTERFLASHING
SPECIFIED SEALANT
SPECIFIED INSULATION
ROOF DECK AS SPECIFIED
GRAVEL SURFACING
INSTALLED INTO REGLET AND
SECURED w/ LEAD WEDGES 8'' O.C.
FLEXIBLE VAPOR RETARDER
TO SERVE AS INSULATION
RETAINER
COMPRESSIBLE INSULATION
WOOD NAILER SECURED TO
DECK w/ APPROPRIATE
FASTENERS, 2 ROWS
STAGGERED EACH ROW
24'' O.C.
STRIPPING
SPECIFIED BASE FLASHING
ROW 12'' O.C.
STAGGERED EACH
BLOCKING, 2 ROWS
NAIL WOOD CANT TO
SHEET TITLE:
DRAWING No.:
SCALE:
NTS
AutoCAD SHX Text
4'' MIN.
| Sheets and Views |
| Model |