Conduit-or-Piping-Support.pdf

PDF 110 KB Posted

Attached to
High School Roof Replacement
Solicitation number
RFP MASO 260000002613 1
Issued by
Genesee County, Edmore Village, Michigan

About this file

This is a technical drawing specification document for roofing and conduit support infrastructure. The drawing (DWG No. 28) illustrates the installation requirements for built-up roofing (BUR) with hot and cold conduit or piping support systems mounted on a roof deck. The specification details the secure fastening of conduit and piping using clamps attached to wood blocking spaced at five-foot intervals across the roof surface. The design includes a specified insulation layer, a BUR membrane, and a treated sheet walk pad for maintenance access. The drawing is presented at a not-to-scale (NTS) ratio and was developed in 2023, serving as a technical reference for construction implementation.

No additional information regarding pricing terms, contract timeline, bidder requirements, funding sources, or contractual award details is contained within this technical specification document. The drawing functions solely as a construction standard and does not address procurement terms, set-asides, incumbent contractors, or other commercial contract provisions.

View the file

Other files

File Type Posted
Typical-Covers-at-Membrane-T-Laps-Model.pdf PDF
2-Piece-Shop-Fabricated-Metal-Edge-Flashing-Model.pdf PDF
Field-Fabricated-Pipe-Flashing-Model.pdf PDF
Curb-for-Air-Handling-Unit.pdf PDF
Wood-Curb-Model.pdf PDF
Base-Sheet-Fastener-7-Inch.pdf PDF
Roof 13 to 15 Detail.pdf PDF
Mason High School Summer of 2027 Roofing Bid Form.doc DOC document
~WRL0001.tmp —
Project-Mason High School THERMastic 80 Roofing Replacements.pdf PDF
Plumbing-Vent-Model.pdf PDF
Equipment-Stand-Rain-Collar.pdf PDF
TLRFIA-over-Steel-Model.pdf PDF
Gauge-or-Thickness-Guide.pdf PDF
Slip-Metal-Skirt-Flashing.pdf PDF
Dail-Water-Stop-Tie-In-Model.pdf PDF
Pitch-Pocket-with-Grout.pdf PDF
Roof-System-Attachment-Slope,-Transition,-Change-in-Plane.pdf PDF
Gutter-Flashing-Model.pdf PDF
Roof-Drain-with-Gravel-Guard.pdf PDF
Hot-Stack-Penetration.pdf PDF
Door-Threshold-Model.pdf PDF
Flashing-for-Non-Wall-Supported (1).pdf PDF
Roof-Hatch-Model.pdf PDF
Metal-Sleeve-and-Storm-Collar.pdf PDF
Metal-Flashing,-Round-to-Square.pdf PDF
Piping-Through-Roof-Deck.pdf PDF
Mason Middle School- Alternate AOC.pdf PDF
Mason High School- AOC.pdf PDF
Mason High School Summer of 2027 Roofing Scope of Work.docx DOCX document
TremPly-KEE-at-Fascia-System-Raised-Cant-Edge-Model.pdf PDF
Composite-Roof-System-Cross-Section-Adhered-ISO-Hot-Model.pdf PDF
Pre-Molded-Pipe-Flashing-Model.pdf PDF
Typical-Edge-Flashing-Model.pdf PDF
Light-Metal-Parapet-Cap.pdf PDF
Notice To Bidders Mason High School Summer of 2027.docx DOCX document
AFFIDAVIT OF COMPLIANCE IRAN.docx DOCX document
Familial Relationship Disclosure.docx DOCX document
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG NO. 28

BUILT UP ROOFING

HOT/COLD CONDUIT OR

PIPING SUPPORT

ROOF DECK AS SPECIFIED

SECURE CONDUIT/ PIPING WITH CLAMP

TO WOOD BLOCKING

WOOD BLOCKING SPACED EVERY 5 FEET

SPECIFIED INSULATION

SPECIFIED BUR

MEMBRANE

WALK PAD

TREMTRED

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

Sheets and Views
Model