About this file
This is a technical drawing specification document for base sheet fastener placement on built-up roofing systems, applicable to state and local construction projects. The specification details the installation requirements for attaching base sheets to roof decking using approved fasteners and discs on lightweight concrete substrates with Tremco materials. Fasteners must be spaced 7 inches on center along sidelaps and in two equally staggered rows down the longitudinal center of the sheet, positioned 12 inches from each edge. The specification mandates increased fastening density at perimeter edges, requiring a 70 percent increase, and at corners, requiring a 160 percent increase, in accordance with FM Global Loss Prevention Data Sheets 1-28 and 1-29. Additional fastener rows must be added and fasteners per row increased as needed based on unit area calculations, with a minimum spacing requirement of 4 inches on center.
The drawing is designated as Drawing No. 15 and provides visual reference for base sheet width measurements and fastener placement intervals. This specification applies to hot or cold base sheet applications using specified Tremco products and fasteners with plates. No pricing terms, contract award dates, renewal options, or project timelines are included in this technical drawing document.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DWG NO. 15
NOTES
1. ATTACH BASE SHEET TO THE ROOF DECKING WITH APPROVED FASTENERS AND DISCS.
2. SPACE FASTENERS 7 INCHES ON CENTER ALONG SIDELAP AND 7 INCHES ON CENTER IN TWO ROWS
EQUALLY STAGGERED DOWN THE LONGITUDINAL CENTER OF THE SHEET (12 INCHES FROM EACH
EDGE).
3. INCREASE PERIMETER EDGE FASTENING BY 70% AND CORNER FASTENING BY 160% PER FM GLOBAL
LOSS PREVENTION DATA SHEETS 1-28 AND 1-29.
4. DETERMINE FASTENER DENSITY ON A UNIT AREA PER FASTENER BASIS. ADD ADDITIONAL ROWS AND INCREASE FASTENERS PER ROW. DO NOT SPACE FASTENERS CLOSER THAN 4 INCHES ON CENTER.
BUILT-UP ROOFING
HOT/COLD BASE SHEET FASTENER
PLACEMENT FOR LIGHTWEIGHT
CONCRETE
SPECIFIED TREMCO
BASE SHEET
SPECIFIED SEPARATOR
LIGHTWEIGHT CONCRETE
SPECIFIED TREMCO
FASTENER AND PLATE
SHEET TITLE:
DRAWING No.:
SCALE:
NTS
AutoCAD SHX Text
BASE SHEET WIDTH
AutoCAD SHX Text 4"
AutoCAD SHX Text 7"
AutoCAD SHX Text 7"
AutoCAD SHX Text 12"