Door-Threshold-Model.pdf

PDF 125 KB Posted

Attached to
High School Roof Replacement
Solicitation number
RFP MASO 260000002613 1
Issued by
Genesee County, Edmore Village, Michigan

About this file

This is a technical drawing specification document for roofing work involving door threshold installation and built-up roofing (BUR) system modifications. The drawing (DWG No. 24) provides detailed construction specifications for a hot/cold door threshold installation that incorporates re-use of an existing threshold plate. The project scope includes application of adhesive, two-ply stripping flashing, specified Tremco base material, specified cant insulation, new membrane installation, new surface-mounted metal counterflashing, and gravel surfacing on an existing door roof deck. The drawing is presented at a scale of NTS (Not To Scale) and was created in 2023.

The document serves as a technical reference for construction execution rather than a procurement instrument. No specific contract terms, pricing information, quantities, response deadlines, site visit schedules, bidder meetings, award dates, or renewal options are detailed in this drawing specification. The document functions as part of the construction contract documentation package and would typically be included with related specifications and bid documents to establish the technical requirements for roofing contractors performing door threshold and built-up roofing work.

View the file

Other files

File Type Posted
Typical-Covers-at-Membrane-T-Laps-Model.pdf PDF
2-Piece-Shop-Fabricated-Metal-Edge-Flashing-Model.pdf PDF
Field-Fabricated-Pipe-Flashing-Model.pdf PDF
Curb-for-Air-Handling-Unit.pdf PDF
Wood-Curb-Model.pdf PDF
Base-Sheet-Fastener-7-Inch.pdf PDF
Roof 13 to 15 Detail.pdf PDF
Roof-System-Attachment-Slope,-Transition,-Change-in-Plane.pdf PDF
Gutter-Flashing-Model.pdf PDF
Roof-Drain-with-Gravel-Guard.pdf PDF
Hot-Stack-Penetration.pdf PDF
Flashing-for-Non-Wall-Supported (1).pdf PDF
Roof-Hatch-Model.pdf PDF
Metal-Sleeve-and-Storm-Collar.pdf PDF
Metal-Flashing,-Round-to-Square.pdf PDF
Piping-Through-Roof-Deck.pdf PDF
Mason Middle School- Alternate AOC.pdf PDF
Mason High School- AOC.pdf PDF
Mason High School Summer of 2027 Roofing Scope of Work.docx DOCX document
TremPly-KEE-at-Fascia-System-Raised-Cant-Edge-Model.pdf PDF
Composite-Roof-System-Cross-Section-Adhered-ISO-Hot-Model.pdf PDF
Pre-Molded-Pipe-Flashing-Model.pdf PDF
Typical-Edge-Flashing-Model.pdf PDF
Light-Metal-Parapet-Cap.pdf PDF
Notice To Bidders Mason High School Summer of 2027.docx DOCX document
AFFIDAVIT OF COMPLIANCE IRAN.docx DOCX document
Familial Relationship Disclosure.docx DOCX document
Mason High School Summer of 2027 Roofing Bid Form.doc DOC document
~WRL0001.tmp —
Project-Mason High School THERMastic 80 Roofing Replacements.pdf PDF
Plumbing-Vent-Model.pdf PDF
Equipment-Stand-Rain-Collar.pdf PDF
TLRFIA-over-Steel-Model.pdf PDF
Conduit-or-Piping-Support.pdf PDF
Gauge-or-Thickness-Guide.pdf PDF
Slip-Metal-Skirt-Flashing.pdf PDF
Dail-Water-Stop-Tie-In-Model.pdf PDF
Pitch-Pocket-with-Grout.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG NO. 24

BUILT-UP ROOFING

HOT/COLD DOOR THRESHOLD

RE-USE EXISTING

THRESHOLD PLATE

ADHESIVE

TWO-PLY

STRIPPING

FLASHING ADHERED

SPECIFED TREMCO BASE

WITH SPECIFIED

SPECIFIED CANT

SPECIFED

INSULATION

MEMBRANE

SPECIFIED BUR

NEW SURFACE MOUNTED

METAL COUNTERFLASHING

EXISTING DOOR

ROOF DECK AS SPECIFIED

GRAVEL SURFACING

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

Sheets and Views
Model

File details come from the government source that posted it. Updated .