Composite-Roof-System-Cross-Section-Adhered-ISO-Hot-Model.pdf

PDF 134 KB Posted

Attached to
High School Roof Replacement
Solicitation number
RFP MASO 260000002613 1
Issued by
Genesee County, Edmore Village, Michigan

About this file

This is a technical drawing document for a composite roof system specification. The drawing illustrates a cross-sectional design for an adhered insulation roof system installed in Type III hot asphalt, designated as Drawing No. 18. The specification details a layered roof assembly consisting of a concrete deck primed with Tremply Kee membrane asphalt primer, followed by insulation layers applied in hot asphalt, an optional gypsum cover board also adhered in Type III hot asphalt, and a top layer secured via hot air weld. The design requires that the bottom layer of insulation be laid in a staggered profile with the top layer offset from the bottom layer to prevent aligned edges, ensuring structural integrity and weatherproofing performance.

The document contains no information regarding pricing, contract terms, timelines, bid submission dates, site visits, pre-bid meetings, funding sources, or award details. This is solely a technical specification drawing and does not include procurement-related contract opportunity information such as set-asides, incumbent contractors, or renewal options. The drawing serves as a reference standard for contractors and construction teams to properly install the composite roof system according to the specified assembly method and material requirements.

View the file

Other files

File Type Posted
Typical-Covers-at-Membrane-T-Laps-Model.pdf PDF
2-Piece-Shop-Fabricated-Metal-Edge-Flashing-Model.pdf PDF
Field-Fabricated-Pipe-Flashing-Model.pdf PDF
Curb-for-Air-Handling-Unit.pdf PDF
Wood-Curb-Model.pdf PDF
Base-Sheet-Fastener-7-Inch.pdf PDF
Roof 13 to 15 Detail.pdf PDF
Roof-System-Attachment-Slope,-Transition,-Change-in-Plane.pdf PDF
Gutter-Flashing-Model.pdf PDF
Roof-Drain-with-Gravel-Guard.pdf PDF
Hot-Stack-Penetration.pdf PDF
Door-Threshold-Model.pdf PDF
Flashing-for-Non-Wall-Supported (1).pdf PDF
Roof-Hatch-Model.pdf PDF
Metal-Sleeve-and-Storm-Collar.pdf PDF
Metal-Flashing,-Round-to-Square.pdf PDF
Piping-Through-Roof-Deck.pdf PDF
Mason Middle School- Alternate AOC.pdf PDF
Mason High School- AOC.pdf PDF
Mason High School Summer of 2027 Roofing Scope of Work.docx DOCX document
TremPly-KEE-at-Fascia-System-Raised-Cant-Edge-Model.pdf PDF
Pre-Molded-Pipe-Flashing-Model.pdf PDF
Typical-Edge-Flashing-Model.pdf PDF
Light-Metal-Parapet-Cap.pdf PDF
Notice To Bidders Mason High School Summer of 2027.docx DOCX document
AFFIDAVIT OF COMPLIANCE IRAN.docx DOCX document
Familial Relationship Disclosure.docx DOCX document
Mason High School Summer of 2027 Roofing Bid Form.doc DOC document
~WRL0001.tmp —
Project-Mason High School THERMastic 80 Roofing Replacements.pdf PDF
Plumbing-Vent-Model.pdf PDF
Equipment-Stand-Rain-Collar.pdf PDF
TLRFIA-over-Steel-Model.pdf PDF
Conduit-or-Piping-Support.pdf PDF
Gauge-or-Thickness-Guide.pdf PDF
Slip-Metal-Skirt-Flashing.pdf PDF
Dail-Water-Stop-Tie-In-Model.pdf PDF
Pitch-Pocket-with-Grout.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

COMPOSITE ROOF SYSTEM

CROSS SECTION (ADHERED

INSULATION IN ASPHALT) DWG NO. 18

NOTES

1. BOTTOM LAYER OF INSULATION SHALL BE LAID DOWN IN A STAGGERED PROFILE. STAGGER AND OFFSET

TOP LAYER OF INSULATION FROM BOTTOM LAYER TO PREVENT ALIGNED EDGES.

HOT AIR WELD

(ADHERED PER SPECIFICATION)

(ADHERED IN TYPE III HOT ASPHALT)

INSULATION PER SPECIFICATION

CONCRETE DECK, PRIME WITH

TREMPLY KEE MEMBRANE

ASPHALT PRIMER (AS SPECIFIED)

GYPSUM COVER BOARD "OPTIONAL"

(ADHERED IN TYPE III HOT ASPHALT)

Sheets and Views
Model