SECT-55_VALVES_AND_ACCESS_FOR_RECLAIMED_WATER_MAINS.doc
DOC document 24 KB Posted
- Attached to
- Grant Funded Construction of Rummell Road Trail
- Solicitation number
- 2025-131
- Issued by
- Polk County, Florida
About this file
The document is a technical specification section (Section 55) for valves and accessories for reclaimed water mains, likely part of a municipal infrastructure project. The specification provides comprehensive standards for valve and accessory selection, installation, and labeling, with specific requirements for resilient seat gate valves, butterfly valves, valve installations, valve boxes, and automatic air release valves. The specification mandates that all valves must be produced by experienced manufacturers and installed according to best practices.
While the specification details technical requirements for water infrastructure components, the related state and local contract opportunity is for a separate project - the Grant Funded Construction of Rummell Road Trail in St. Cloud, Florida. This trail project, partially funded by the Florida Department of Environmental Protection Recreational Trails Program, involves constructing an 8-foot wide asphalt trail approximately 6,400 linear feet long and a 5-foot wide concrete sidewalk about 1,125 linear feet in length. The project includes utility relocation, stormwater infrastructure installation, driveway and sidewalk construction, signage, striping, and a trail head park segment with parking area and a dry pond.
View the file
Other files
Show all 48
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 55 – VALVES AND ACCESSORIES FOR RECLAIMED WATER MAINS
Item No.
Title 55.1
GENERAL
55.2
RESILIENT SEAT GATE VALVES
55.3
BUTTERFLY VALVES
55.4
VALVE INSTALLATION
55.5
VALVE BOXES
55.6
AUTOMATIC AIR RELEASE VALVES
55.1
GENERAL
All valves and appurtenances shall be products of well established firms who are fully experienced and qualified in the manufacture of the particular equipment to be furnished. The equipment shall be designed, constructed, and installed in accordance with the best practices and methods and shall comply with these specifications as applicable.
55.2
RESILIENT SEAT GATE VALVES
Standards and specifications as set forth in Section 52.2 shall apply.
55.3
BUTTERFLY VALVES
Standards and specifications as set forth in Section 52.3 shall apply.
55.4
VALVE INSTALLATION
Standards and specifications as set forth in Section 52.4 shall apply.
55.5
VALVE BOXES
Standards and specifications as set forth in Section 52.5 shall apply except valve box covers shall have, "CAUTION - RECLAIMED WATER", cast into the top for all reclaimed water mains.
55.6
AUTOMATIC AIR RELEASE VALVES
Standards and specifications as set forth in Section 52.6 shall apply.