About this file

This document contains a justification for a single source award and details of a related federal contract opportunity. The single source justification is for the Jeron Health Care Call System Provider 790 Nurse Call System, which is the only product that integrates with the existing nurse call system installed at the Clement J. Zablocki VA Medical Center. The estimated cost is $35,000. The related federal contract opportunity is a pre-solicitation notice to renovate approximately 11,000 square feet on the 7th floor of the medical center for a GI procedure clinic. The project value is between $2-5 million and has a 515 calendar day period of performance. The solicitation is set aside for Service-Disabled Veteran-Owned Small Businesses and will be posted on SAM.gov on October 15th, with bid opening scheduled for November 16th. A pre-bid conference will also be held.

View the file

Other files

File Type Posted
36C25221B0002 0003.docx DOCX document
S06 - ET101 - SEVENTH FLOOR PLAN - TECHNOLOGY - Amd03.pdf PDF
36C25221B0002 0002.docx DOCX document
S06 - Appendix E - Physicist Report.pdf PDF
S06 - AE501 - BUILDING DETAILS.pdf PDF
S06 - EP602 - SCHEDULES POWER.pdf PDF
S06 - ET101 - SEVENTH FLOOR PLAN - TECHNOLOGY.pdf PDF
S06 - DG107 - SEVENTH FLOOR MEDICAL GAS PLAN.pdf PDF
S06 - 08 71 13.11 - LOW ENERGY DOOR OPERATORS Amend No2.pdf PDF
S06 - 7AN_ShieldingReport_20200601.pdf PDF
S06 - AE002 - WALL TYPES.pdf PDF
S06 - AE101 - SEVENTH FLOOR ARCHITECTURAL PLAN.pdf PDF
S06 - ET501 - DETAILS - TECHNOLOGY.pdf PDF
S06 - 11 73 00 - CEILING MOUNT PATIENT LIFT Amend No2.pdf PDF
S06 - GC101 - INFECTION CONTROL_PHASING PLAN.pdf PDF
S06 - EP401 - POWER RISERS.pdf PDF
S04 - Site Visit Sign-In Sheet - 695-19-107.pdf PDF
36C25221B0002 0001.docx DOCX document
S02 - Wage Determination Effective 10.2.2020.pdf PDF
S02 - J_A 695-19-107_Door Hardware.pdf PDF
S02 - J_A 695-19-107_HVAC BAS.pdf PDF
S02 - 695-19-107_2020.09.24_Volume 2 Specifications 100percent.pdf PDF
S02 - 695-19-107_2020.09.24_Volume 1 Specifications 100percent.pdf PDF
S02 - J_A 695-19-107_Interior Signage.pdf PDF
S02 - J_A 695-19-107_Firestop Systems.pdf PDF
S02 - 695-19-107 Drawing Set Updated.pdf PDF
S02 - J_A 695-19-107_Medical Gas Systems.pdf PDF
36C25221B0002_1.docx DOCX document
S02 - J_A 695-19-107_Card Readers.pdf PDF
S02 - J_A 695-19-107_Fire Alarm System.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VHAPM Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under the SAT

VHAPM Part 813.106 Page 1 of 1 Original Date: 08/30/17 Revision 02 Eff Date: 03/31/2020

DEPARTMENT OF VETERANS AFFAIRS

Justification for Single Source Awards IAW FAR 13.106-1 For Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K)

Acquisition Plan Action ID: 36C252-20-AP-3856

1. Contracting Activity: Department of Veterans Affairs, Great Lakes Acquisition Center, NCO 12, 115 South

84th Street, Milwaukee, WI 53214. Requesting Activity: Department of Veterans Affairs, VISN 12, Clement J.

Zablocki VA Medical Center, 5000 W. National Avenue, Milwaukee WI 53295. Purchase Request (2237) number: 695-21-1-6940-0001.

2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount:

The Jeron Health Care Call System Provider 790 Nurse Call System is the only product that allows for a single

Nurse Call system for the Milwaukee facility. It cannot be expanded by other vendors or manufacturers and can only be expanded by the same vendor/manufacturer. Cost estimate: $35,000.00.

3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:

Jeron Nurse Call System signals are sent back to head end equipment in Building 111. The backbone of the system has already been installed at great expense. This project’s expansion of the hospital’s Nurse Call system will be a modification of the existing system and not a new system. An incompatible system will require installation of new head end and backbone components – extremely cost prohibitive. Installation of a system that interfaces properly with the existing system in Building 111 will ensure patient safety because communications will be seamless. Installation of components that match the existing nurse call system minimizes maintenance costs and bench stock requirements. No other system will integrate with our existing

Nurse Call system.

4. Description of market research conducted and results or statement why it was not conducted:

No other system that offers a seamless integration with our existing Nurse Call system.

5. Contracting Officer's Certification: Purchase is approved in accordance with FAR13.106-1(b). I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.

_________________________________ ___10/08/2020_______ Name Date Title https://www.acquisition.gov/?q=/browse/far/13 https://acquisition.gov/far/current/html/Subpart%2013_1.html#wp1125466

2020-10-08T11:39:03-0500
Stacy G. Hoover 1390440