About this file

This document contains a medical gas plan drawing and related federal contract opportunity notice. The contract opportunity is for renovation work at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin. The project will demolish and renovate approximately 11,000 square feet of space on the seventh floor for a relocated GI procedure clinic. The renovation work will update and correct mechanical, electrical, plumbing, medical gases, fire protection, nurse call and other building systems. The estimated value is between $2-5 million. The NAICS code is 236220 for nonresidential building construction and the size standard is $39.5 million. The completion period is 515 calendar days. The solicitation is set aside for Service-Disabled Veteran-Owned Small Businesses. The solicitation and drawings are scheduled for posting on SAM.gov by October 15, 2020 with a bid opening of November 16, 2020. A pre-bid site walkthrough will be held.

View the file

Other files

File Type Posted
36C25221B0002 0003.docx DOCX document
S06 - ET101 - SEVENTH FLOOR PLAN - TECHNOLOGY - Amd03.pdf PDF
36C25221B0002 0002.docx DOCX document
S06 - Appendix E - Physicist Report.pdf PDF
S06 - AE501 - BUILDING DETAILS.pdf PDF
S06 - EP602 - SCHEDULES POWER.pdf PDF
S06 - ET101 - SEVENTH FLOOR PLAN - TECHNOLOGY.pdf PDF
S06 - 08 71 13.11 - LOW ENERGY DOOR OPERATORS Amend No2.pdf PDF
S06 - 7AN_ShieldingReport_20200601.pdf PDF
S06 - AE002 - WALL TYPES.pdf PDF
S06 - AE101 - SEVENTH FLOOR ARCHITECTURAL PLAN.pdf PDF
S06 - ET501 - DETAILS - TECHNOLOGY.pdf PDF
S06 - 11 73 00 - CEILING MOUNT PATIENT LIFT Amend No2.pdf PDF
S06 - GC101 - INFECTION CONTROL_PHASING PLAN.pdf PDF
S06 - EP401 - POWER RISERS.pdf PDF
S04 - Site Visit Sign-In Sheet - 695-19-107.pdf PDF
36C25221B0002 0001.docx DOCX document
S02 - Wage Determination Effective 10.2.2020.pdf PDF
S02 - J_A 695-19-107_Door Hardware.pdf PDF
S02 - J_A 695-19-107_HVAC BAS.pdf PDF
S02 - 695-19-107_2020.09.24_Volume 2 Specifications 100percent.pdf PDF
S02 - 695-19-107_2020.09.24_Volume 1 Specifications 100percent.pdf PDF
S02 - J_A 695-19-107_Interior Signage.pdf PDF
S02 - J_A 695-19-107_Firestop Systems.pdf PDF
S02 - 695-19-107 Drawing Set Updated.pdf PDF
S02 - J_A 695-19-107_Medical Gas Systems.pdf PDF
36C25221B0002_1.docx DOCX document
S02 - J_A 695-19-107_Card Readers.pdf PDF
S02 - J_A 695-19-107_Nurse Call.pdf PDF
S02 - J_A 695-19-107_Fire Alarm System.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1" OXY

UP & DN.

1 1/4"

1 1/4" MV UP & DN. MV

STAFF TOILET

7214B

STAFF LOUNGE /

TRAINING

OPEN OFFICE

OFFICE

7216B

OFFICE

7216A

SPECIAL EXAM RM

PATIENT TOILET

7215A

LOCKERS

CLEAN UTILITY

CORRIDOR

C7A02

ELECTRICAL

ELECTRICAL

ELECTRICAL

CORRIDOR

C7A04

FLUOROSCOPY

PREP / RECOVERY

7231PREP / RECOVERY

PREP / RECOVERY

TEAM LEAD

PREP / RECOVERY

PREP / RECOVERY

PREP / RECOVERY

PREP / RECOVERY

PREP / RECOVERY

WORKROOM

CORRIDOR

C7A01

RECEPTION

WAITING

GI ENDOSCOPY

CONSULT

FAMILY TOILET

PATIENT TOILET

GI ENDOSCOPY

GI ENDOSCOPY

CONTROL ROOM

SCOPE STORAGE

PHYSICIAN /

RESIDENT WORK

STATIONS

7239 ANESTHESIA WORK

RM

7239A

PRIVATE TOILET

7233A

MEDICATION

MECH.

HAC

EQUIP. ROOM

7209A

MSA

URINALYSIS LAB

7152PUBLIC TLT

WAITING ROOM

CORRIDOR

C7A14

CORRIDOR

C7A13

INTAKE

RECEPTION

EXAM

OFFICE

7158 OFFICE

OFFICE

CORRIDOR

C7A08

OFFICE

7155 OFFICE

OFFICE

TRAINING/CONSULT

EC

EC

CENTRAL SCOPE

AND EQUIPMENT

STORAGE

SOILED UTILITY

CO2 STORAGE

7206A

CHANGING ROOM

7214A

23 25222119 2016 171311 12109

A

B

C

D

E

H

K L

M

J

ZVB-2

MV MA O MV

MA

O

MAO MV MV MA O

MA O

MA

MV

O

EXISTING 2 1/2" MEDICAL AIR RISER LOCATION

M A

M A

1"

1"

1"

PROVIDE FULL SIZE

VALVE & CAPPED

PIPE FOR FUTURE

MA

M A

1"

MV

MA

O

O M

A M

V

MV

MA

O

MV

MA

O

M A

MA

1 1/2"

(2)

1 1/2"

ZVB-1

O M

A M

V

MV

O

MA

MV

MA

O

MV

MA

O

O

MA

MV

O

MV

O

MV

O

O M

A M

V

MV

O

MV

O

M V O

NOTE:

WORK BEYOND LIMIT OF PROJECT-

THIS IS AN ACTIVE EMPLOYEE WORK AREA 6AM - 5PM MONDAY - FRIDAY. THE CONTRACTOR SHALL BE ALLOWED ACCESS TO PORTIONS OF THIS AREA TO COMPLETE PLUMBING (INCLUDES MEDICAL GAS) DEMOLITION, RELOCATIONS AND NEW WORK DURING OFF-SHIFT. THE

CONTRACTOR SHALL PLAN FOR PHASES FOR THIS WORK. PLUMBING SHALL BE COORDINATED. EACH PHASE SHALL HAVE ITS OWN PLASTIC

INFECTION CONTROL BARRIER WITH ZIP-WALLS AND NEGATIVE AIR MACHINES. CEILINGS SHALL BE RETURNED TO NORMAL AT THE END OF

THE WORK DAY. OFF SHIFT WORK IS ACCEPTABLE WITH COR PERMISSION. OUTAGES SHALL BE OFF SHIFT. EACH SUB-PHASE REQUIRES ITS OWN INFECTION CONTROL WORKPLAN. AN OVERALL SUB-PHASING PLAN IS REQUIRED DURING PRE-CONSTRUCTION SUBMITTAL PHASE TO

COORDINATE ACCESS TO THIS SPACE AND MOVES BY VA PERSONNEL.

1/2"1/2"1"

3/4" MV, 1/2" MA & OXY DN

(TYPICAL FOR EACH

PREP/ RECOVERY ROOM)

1/2"

3/4" 1/2"

3/4"

1/2"

1/2"

3/4"

3/4"

1/2"

3/4"3/4" 1"

1"1"

1 1/4"

3/4"

3/4" 1"

3/4" 3/4" 1"

1" 1/2" 1/2"

3/4"

1/2"1/2" 1"3/4"3/4" 1" 1/2"1/2"

MGA-1,

MGA-2,

MGA-3,

TMA-1

TRANSDUCERS - ALARM MUST BE

WIRED SEPARATELY OFF OF

MEDICAL MAINS AS FLUOROSCOPY

IS AN ANESTHESIA LOCATION

TRANSDUCERS

3-PIECE SECTIONAL

VALVES WITH

LOCKABLE HANDLES

(TYPICAL)

M V

O M

A

EXISTING ZVB:

PROVIDE BLANK COVER PLATE

LABELED AS "SERVICE VALVES"

PROVIDE NEW 1" MA VALVE AND

PIPING THROUGH BOX. PROTECT

EXISTING O & MV VALVES AND

PIPING DURING CONSTRUCTION

CO2

CO2

EQUIPMENT

BOOM

EQUIPMENT

BOOM

MV

EQUIPMENT

BOOM

MA

EQUIPMENT

BOOM

MA

MA

M A

MA

1/2"

MV

MA

O

CO2

MANIFOLD

ROOM

MV

MA

O

MV

MA

O

O

MV

MA

O

CO2

MV O

CO2

MAMV O

CO2

CO2

CO2

M V

M A

C O

CO2

MANIFOLD

CO2CO2

C O

CO2

C O

CO2

C O

M V

M A

O

O M

A M

V

M V

M A

O

M V

M A

O

M V

M A

O

M V

M A

O O M

A M

V

CO2 EXHAUST

LOCATION

MV

MA

MA MVO

WAGD

CEILING

OUTLETS

MA MVO

WAGD

CEILING

OUTLETS

MAMV O

MA MVO WAGD

CEILING

OUTLETS

MA

M A

MV

MA

O

CO2

1/2"

1/2"

1/2"

1/2"

1" 1/2" 1/2" 1/2"

W A

G D

M V

C O

M

A O

ZVB-3

TRANSDUCERS - ALARM MUST BE WIRED

SEPARATELY OFF OF MEDICAL MAINS AS

ENDOSCOPY 7207 IS AN ANESTHESIA LOCATION

1/2"

3/4"

1/2" 1/2"

1/2" 3/4"

1/2"

3/4"

1/2"

1/2"

3/4" 3/4" 1/2" 1/2"

1/2"

1"1" 1 1/4"

1/2"

1" 1/2"1/2"1/2" 1"

MV

O

3/4"

1/2"1/2"

3/4"

1/2"

3/4"

1" MA DN.

1/2"

1"

1/2"

1/2"1/2"

3/4" 1/2"1/2"3/4"

1/2"

3/4"

1"

1/2"1/2"1/2"

N

PROJECT AREAA

B

C

MEDICAL GAS GENERAL NOTES

A

B

C

D

E

REMOVE, CAP AND SEAL PIPING FROM OUTLETS BEING REMOVED, BACK TO

THE POINT OF ORIGIN, OR THE LAST FITTING WITH FLOW.

ABOVE CEILING DEMOLITION, NEW AND RESTORATION WORK ON THE 7TH

OR 6TH FLOORS - WITH THE EXCEPTION OF UTILITY OUTAGES THAT AFFECT

PATIENT CARE, DISRUPT HOSPITAL OPERATIONS OR REQUIRE A

CURTAILMENT OF SERVICES MEMO - CAN BE COMPLETED DURING ANY

SHIFT ONCE INFECTION CONTROL BARRIERS ARE ESTABLISHED AND

APPROVED PER THE SUBMITTED PHASING AND WORKPLAN. THE

CONTRACTOR MAY WORK OFF-SHIFT AS WELL TO COMPLETE

CONSTRUCTION ACTIVITIES IN AN EXPEDITED MANNER. UTILITY OUTAGES

THAT AFFECT PATIENT CARE, DISRUPT HOSPITAL OPERATIONS OR REQUIRE

A CURTAILMENT OF SERVICES MEMO MUST BE COMPLETED ON 2ND AND

3RD SHIFTS ON WEEKDAYS OR ANYTIME ON WEEKENDS (SATURDAY AND

SUNDAY).

SEE ARCHITECTURAL PLANS FOR PROJECT PHASING DRAWINGS AND

NOTES.

6TH FLOOR CEILING TILES WHICH MUST BE REMOVED FOR ABOVE CEILING

WORK SHALL BE CAREFULLY REMOVED AND STORED IN A SAFE MANNER

UNTIL CEILING TILES CAN BE REINSTALLED. DAMAGED AND BROKEN CEILING

TILES SHALL BE REPLACED BY THE CONTRACTOR. ASSUME ALL CEILINGS

ARE ACOUSTIC TILE AND GRID UNLESS NOTED AS GYPSUM BOARD CEILINGS

ON ARCHITECTURAL. AFFECTED HARD CEILINGS SHALL BE PATCHED AND

PAINTED FOR A FLUSH AND SEAMLESS CONDITION TO MATCH EXISTING

EXACTLY. CONTRACTOR TO VERIFY ALL EXISTING CEILING TYPES ON THE

6TH FLOOR IN FIELD.

THE WORKPLAN FOR 6TH FLOOR ACTIVITIES SHALL BE ORGANIZED BY THE

CONTRACTOR SUCH THAT ALL TRADES (ELECTRICAL, PLUMBING,

MECHANICAL, FIRE PROTECTION, DRAIN, ETC.) DEMOLITION, NEW AND

RESTORATION ACTIVITIES - TO INCLUDE ESTABLISHMENT OF INFECTION

CONTROL BARRIERS, INSPECTIONS, AND SEALING OF PENETRATIONS - CAN

BE COMPLETED IN THREE (3) WEEKS OR LESS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

B

R e v it L o c a lF ile s \2

\9

-P

R D

-W O

Z M

J .r v t

/8

/2

:5

:2

P M

DG107

SEVENTH FLOOR MEDICAL GAS

PLANGUIDON DESIGN INC.

1221 N. Pennsylvania St.

Suite 200

Indianapolis, Indiana 46202

317.800.6388

RING & DUCHATEAU, LLP.

17400 W. Capital Drive

Brookfield, WI 53045

414.778.1700

RENOVATE 7AN FOR

ENDOSCOPY LAB

5000 W National Ave, Milwaukee, WI 53295

695-19-107

08/21/2020 RJW MJW

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/8" = 1'-0"DG107

1 SEVENTH FLOOR MEDICAL GAS PLAN

N

TRUE NORTH PROJECT NORTH

SCALE: 1" = 100'-0"

VA 7AN KEY PLANN

Revisions: Date:

ACCOMPANYING 36C25221B0002 0002

VHAMIWBeierJ Text Box

ZVB-0707

VHAMIWBeierJ Text Box

ZVB-0705

VHAMIWBeierJ Text Box

ZVB-0706

VHAMIWBeierJ Text Box

MGA-0703

VHAMIWBeierJ Text Box

MGA-0704

VHAMIWBeierJ Text Box

MGA-0705

VHAMIWBeierJ Text Box

TMA-0701

VHAMIWBeierJ Text Box Amendment 0002

VHAMIWBeierJ Text Box 11/17/2020

VHAMIWBeierJ Text Box Amendment 0002 clarification - Zone Valve Boxes and Alarm Panels have just been re-tagged in this amendment drawing.

File details come from the government source that posted it. Updated .