S06 - AE101 - SEVENTH FLOOR ARCHITECTURAL PLAN.pdf

PDF 980 KB Posted

Attached to
Z2DA--Renovate 7AN for GI/GU and Procedure Clinic Project# 695-19-107 Clement J. Zablocki VA Medical Center Milwaukee, WI
Solicitation number
36C25221B0002
Issued by

About this file

This document includes architectural plans and specifications for the renovation of the seventh floor at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin, as well as a pre-solicitation notice for the related construction contract opportunity. The renovation project will demolish and renovate approximately 11,000 square feet of existing interior spaces on the seventh floor to relocate the GI Procedure Clinic and will update mechanical, electrical, plumbing, medical gas, fire protection, and pneumatic tube systems. The pre-solicitation notice is for a construction contract with a value between $2 million and $5 million to complete the renovation project. The solicitation will be posted on October 15, 2020 with a bid opening scheduled for November 16, 2020. A pre-bid conference will also be held. The contract is set aside for Service-Disabled Veteran-Owned Small Businesses and has a North American Industry Classification System code of 236220 and size standard of $39.5 million. The completion period is 515 calendar days from notice to proceed.

View the file

Other files

File Type Posted
36C25221B0002 0003.docx DOCX document
S06 - ET101 - SEVENTH FLOOR PLAN - TECHNOLOGY - Amd03.pdf PDF
36C25221B0002 0002.docx DOCX document
S06 - Appendix E - Physicist Report.pdf PDF
S06 - AE501 - BUILDING DETAILS.pdf PDF
S06 - EP602 - SCHEDULES POWER.pdf PDF
S06 - ET101 - SEVENTH FLOOR PLAN - TECHNOLOGY.pdf PDF
S06 - DG107 - SEVENTH FLOOR MEDICAL GAS PLAN.pdf PDF
S06 - 08 71 13.11 - LOW ENERGY DOOR OPERATORS Amend No2.pdf PDF
S06 - 7AN_ShieldingReport_20200601.pdf PDF
S06 - AE002 - WALL TYPES.pdf PDF
S06 - ET501 - DETAILS - TECHNOLOGY.pdf PDF
S06 - 11 73 00 - CEILING MOUNT PATIENT LIFT Amend No2.pdf PDF
S06 - GC101 - INFECTION CONTROL_PHASING PLAN.pdf PDF
S06 - EP401 - POWER RISERS.pdf PDF
S04 - Site Visit Sign-In Sheet - 695-19-107.pdf PDF
36C25221B0002 0001.docx DOCX document
S02 - Wage Determination Effective 10.2.2020.pdf PDF
S02 - J_A 695-19-107_Door Hardware.pdf PDF
S02 - J_A 695-19-107_HVAC BAS.pdf PDF
S02 - 695-19-107_2020.09.24_Volume 2 Specifications 100percent.pdf PDF
S02 - 695-19-107_2020.09.24_Volume 1 Specifications 100percent.pdf PDF
S02 - J_A 695-19-107_Interior Signage.pdf PDF
S02 - J_A 695-19-107_Firestop Systems.pdf PDF
S02 - 695-19-107 Drawing Set Updated.pdf PDF
S02 - J_A 695-19-107_Medical Gas Systems.pdf PDF
36C25221B0002_1.docx DOCX document
S02 - J_A 695-19-107_Card Readers.pdf PDF
S02 - J_A 695-19-107_Nurse Call.pdf PDF
S02 - J_A 695-19-107_Fire Alarm System.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

23 25222119 2016 171311 12109

A

B

C

D

E

H

K

L

M

J

PREP / RECOVERY

PREP / RECOVERY

PREP / RECOVERY

PREP / RECOVERY

PREP / RECOVERY

PREP / RECOVERY

MEDICATION

PHYSICIAN /

RESIDENT WORK

STATIONS

MECH.

PRIVATE TOILET

7233A

PREP / RECOVERY

PREP / RECOVERY

OFFICE

7216A

OFFICE

7216B

OPEN OFFICE

STAFF LOUNGE /

TRAINING

SPECIAL EXAM RM

PATIENT TOILET

7215A

CLEAN UTILITY

ELECTRICAL

ELECTRICAL

ELECTRICAL

SCOPE STORAGE

7210GI ENDOSCOPY

GI ENDOSCOPY

CONTROL ROOM

FLUOROSCOPY

PATIENT TOILET

CONSULT

WORKROOM

FAMILY TOILET

WAITING

RECEPTION

TEAM LEAD

STAIR

STAIR 7-5

GI ENDOSCOPY

ANESTHESIA WORK

RM

7239A

UP

7230A

7-5

7207B

C7A02

7207A 7209

7215A

7216B7216A

7239A

7233A

OFFICE

TRAINING/CONSULT

CORRIDOR

C7A14

OFFICE

STORAGE

ELEV

7-A-8

ELEV

7-A-7

OFFICE

EC

EC

HAC

FAC

7A05

CORRIDOR

C7A02

CORRIDOR

C7A04

CORRIDOR

C7A01

C7A04

AI201

AI201

AI205

STAFF TOILET

7214B

EQUIP. ROOM

7209A

AI201

AI201

7205B

7244A

7244B 7236B

7205A

AE501

AI205

7209A

AI204

AI203

1AI202

AI204

B

AI201

AI203

C7A01

OFFICE

OFFICE

OFFICE

OFFICE

EXAM

OFFICE

URINALYSIS LAB

PUBLIC TLT

WAITING ROOM

MSA

RECEPTION

INTAKE

CORRIDOR

C7A13

CORRIDOR

C7A08

AE501

OFFICE

OFFICE

EXAM

OFFICE

VP

7-29

HAC

TOILET

EXAM

EXAM

DIRTY SUPPLY

73137

ELEV.

7-B-10

ELEV.

7-B-11

Room

ELEV.

7-A-5

ELEV.

7-A-6

OFFICE

EXAM

TOILET

STAIR

7-1

EXAM

ENT SUPPLY

7306A

ENT OFFICE

ELEV.

7-B-9

ELEV.

7-B-12

ELEV. LOBBY

C7B05

CORRIDOR

C7B04

7230B

CORRIDOR

C7B01

AI201

AI202

AI203

SOILED UTILITY

AI204

7214B

7217B

AI201

LOCKERS

CENTRAL SCOPE

AND EQUIPMENT

STORAGE

TYP.

AI201

CC

7242 7236A

7217A

AE501

A

AE501

AE501

AE501

AE501

CO2 STORAGE

7206A

7206A

5 5

TYP. X 6

LV-2

LV-2 LV-1

LV-1

TYP.

AI204

AE501

AE501

CHANGING ROOM

7214A

AE501

Sim

ARCHITECTURAL GENERAL NOTES

ARCHITECTURAL PLAN NOTES

A

B

C

D

E

F

G

H

I

J

REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION AND

ELECTRICAL FOR COORDINATION ITEMS. COORDINATE AS REQUIRED

INCLUDING NECESSARY FRAMING, BLOCKING, ETC.

VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND

REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.

PATCH EXISTING WALLS WHERE NEW WALLS MEET.

ALL HANDRAILS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE

WITH ALL REQUIREMENTS OF AMERICANS WITH DISABILITIES ACT

GUIDELINES AND ALL CODES AND REGULATIONS HAVING JURISDICTION, THE

MOST STRINGENT SHALL PREVAIL.

PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER ABA REQUIREMENTS.

WHERE NO DIMENSION IS INDICATED, FINISH DOORS 6" FROM EDGE OF

STUD FRAMING AT CORNERS UNLESS OTHERWISE NOTED.

REFER TO SHEET QH101 FOR EQUIPMENT SCHEDULE AND INFORMATION.

REFER TO SHEET AE003 FOR ACCESSORIES TO BE PROVIDED IN THE

TOILET/BATH ROOMS AND AT THE HAND LAVATORIES.

LEVEL AND INFILL FLOOR SLAB TO RECEIVE NEW FLOORING. REFER TO

SPECIFICATIONS AND FLOORING MANUFACTURE'S TOLERANCES FOR

ADDITIONAL INFORMATION.

PROVIDE METAL PLATE ON UNDERSIDE OF FLOOR SLAB WHERE CONCRETE

INFILL IS REQUIRED AND CHIP AWAY CONCRETE AT FLOOR LEVEL TO

CREATE A SLOPED OPENING/LIP TO PATCH PENETRATIONS AND PREVENT

CONCRETE INFILL CORE FROM FALLING THROUGH OPENING TO FLOOR

BELOW.

PROVIDE BLOCKING 60"-80" AFF AND 24" TO EITHER SIDE OF LCD SCREEN

MOUNTING CENTER LINE. COORDINATE ELECTRICAL AND DATA ROUGH IN

WITH ENGINEERING DRAWINGS.

PROVIDE CONCRETE INFILL AT RECESSED SLAB FROM CERAMIC TILE

REMOVAL. APPROXIMATELY 2" INFILL TO BE FLUSH WITH FLOOR TO

RECEIVE NEW FINISHES. SHADE INDICATES APPROXIMATE AREA OF INFILL.

LOCATION FOR AUTOMATIC DOOR OPERATOR DOOR ACTUATOR. REFER

TO DOOR SCHEDULE AND ENGINEERING DRAWINGS FOR ADDITIONAL

INFORMATION.

NOT USED

PROVIDE TYPICAL COLUMN WRAP - REFER TO DETAIL 5/AE501.

PROVIDE CONCRETE PAD FOR AIR HANDLING UNIT. REFER TO DETAIL

18/AE501.

LOCATION OF PNEUMATIC TUBE - REFER TO MANUFACTURER'S DRAWINGS

PROVIDE ROLLER SHADE FOR WINDOW IN THIS ROOM.

STRUCTURAL STEEL FRAME FOR MECHANICAL EQUIPMENT. REFER TO

DETAIL 18/AE501. REFER TO MECHANICAL EQUIPMENT FOR FINAL STEEL

LAYOUT.

PROJECT AREAA

B

C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C U s e rs

\d v a lla n d in g h a m \D o c u m e n ts

\1

.1

.1

R e n o v a te

A N d v a lla n d in g h a m g u id o n d e s ig n .c o m

.r v t

/1 /2

:1

:1

P M

AE101

SEVENTH FLOOR

ARCHITECTURAL PLANGUIDON DESIGN INC.

1221 N. Pennsylvania St.

Suite 200

Indianapolis, Indiana 46202

317.800.6388

RING & DUCHATEAU, LLP.

17400 W. Capital Drive

Brookfield, WI 53045

414.778.1700

RENOVATE 7AN FOR

ENDOSCOPY LAB

5000 W National Ave, Milwaukee, WI 53295

695-19-107

08/21/2020 DV JDJ

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

SCALE: 1/8" = 1'-0"AE101

1 SEVENTH FLOOR PLAN - ARCHITECTURALN

SCALE: 1" = 100'-0"

KEY PLAN

Revisions: Date:

ADDENDUM 01 2020/11/13

ACCOMPANYING 36C25221B0002 0002

VHAMIWBeierJ Text Box Amendment 0002

VHAMIWBeierJ Text Box 11/17/2020

File details come from the government source that posted it. Updated .