RFP Attachment 9 - Drawings 695-21-700 Part 2.pdf

PDF 2 MB Posted

Attached to
Y1DZ--EHRM Infrastructure Upgrades Tier 1 Construction 695-21-700 Milwaukee
Solicitation number
36C77626R0002
Issued by

About this file

These are Life Safety Plans for EHRM Infrastructure Upgrades in Milwaukee, Wisconsin, prepared for the U.S. Department of Veterans Affairs by Romanyk Consulting and IMEG. The document set comprises final bid documents (695-21-700) containing floor-by-floor life safety plans for multiple buildings at the Milwaukee VA facility.

The plans cover Buildings 111, 112, 113, 123, 144, 146, 147, and 148, with detailed floor layouts showing life safety infrastructure including fire barriers, smoke zones, egress routes, emergency lighting, fire extinguishers, manual pull stations, and telecommunications rooms. Building 111 includes Levels 05 through 10 with healthcare and ambulatory occupancy designations and square footages ranging from 51,744 to 61,851 square feet. Building 112 (Level 01, facility infrastructure), Building 113 (ground floor mechanical systems), Building 123 (Level 01 dormitory occupancy, 106,646 square feet), and Buildings 144, 146, 147, and 148 (basement and ground floor levels) contain mixed occupancy types including healthcare, business, and dormitory uses. All facilities are fully sprinklered in accordance with NFPA 13 and protected with supervised automatic smoke detection systems. The plans establish maximum travel distances, identify hazardous room enclosures, detail exit passageways and stairwells, and designate areas open to corridors with or without smoke detection requirements. Wall types and additional technical details are referenced on companion drawing GC102. All plans are dated September 5, 2025, and coordinate all construction-related activities with the Contracting Officer Representative prior to performance.

View the file

Other files

File Type Posted
695-21-700 Technical Question Tracking Sheet - Milw EHRM FINAL 7-22-26.pdf PDF
695-21-700 Amend 5 CIVIL UPDATED Narrative 2026-07-17.pdf PDF
695-21-700 Amend 5 CIVIL UPDATED full set 2026-07-17.pdf PDF
36C77626R0002 0005.docx DOCX document
695-21-700 CIVIL Full - 7-10-26.pdf PDF
695-21-700 Tech Qtn Tracking Sheet - Milw EHRM FINAL 7-15-26.pdf PDF
695-21-700 Specs Part 1 - 7-10-26.pdf PDF
695-21-700 Specs Part 3 - 7-10-26.pdf PDF
695-21-700 TECH Full - 7-10-26.pdf PDF
695-21-700 Specs Part 2 - 7-10-26.pdf PDF
695-21-700 ELEC Full - 7-10-26.pdf PDF
695-21-700 FIRE X Full - 7-10-26.pdf PDF
695-21-700 MECH Full - 7-10-26.pdf PDF
695-21-700 Site Visit Sign In Sheet 5-6-2026.pdf PDF
36C77626R0002 Amendment 0001.pdf PDF
RFP 36C77626R0002.pdf PDF
RFP Attachment 3 - Division Cost Breakdown - Milwaukee.xlsx XLSX spreadsheet
RFP Attachment 10 - Drawings 695-21-700 Part 3.pdf PDF
RFP Attachment 14 - Drawings 695-21-700 Part 7.pdf PDF
RFP Attachment 21 - Drawings 695-21-700 Part 14.pdf PDF
RFP Attachment 26 - Drawings 695-21-700 Part 19.pdf PDF
RFP Attachment 2 - Site Visit - Milwaukee.pdf PDF
RFP Attachment 7 - Specs 695-21-700 Part 3.pdf PDF
RFP Attachment 12 - Drawings 695-21-700 Part 5.pdf PDF
RFP Attachment 16 - Drawings 695-21-700 Part 9.pdf PDF
RFP Attachment 19 - Drawings 695-21-700 Part 12.pdf PDF
RFP Attachment 23 - Drawings 695-21-700 Part 16.pdf PDF
RFP Attachment 24 - Drawings 695-21-700 Part 17.pdf PDF
RFP Attachment 25 - Drawings 695-21-700 Part 18.pdf PDF
RFP Attachment 32 - Drawings 695-21-700 Part 25.pdf PDF
RFP Attachment 36 - PPQ.docx DOCX document
RFP Attachment 1 - DBA Rates - Milwaukee County - 1-2-26.pdf PDF
RFP Attachment 4 - Limitations on Subcontracting - Milwaukee.docx DOCX document
RFP Attachment 6 - Specs 695-21-700 Part 2.pdf PDF
RFP Attachment 15 - Drawings 695-21-700 Part 8.pdf PDF
RFP Attachment 17 - Drawings 695-21-700 Part 10.pdf PDF
RFP Attachment 27 - Drawings 695-21-700 Part 20.pdf PDF
RFP Attachment 29 - Drawings 695-21-700 Part 22.pdf PDF
RFP Attachment 31 - Drawings 695-21-700 Part 24.pdf PDF
RFP Attachment 33 - Drawings 695-21-700 Part 26.pdf PDF
RFP Attachment 34 - Drawings 695-21-700 Part 27.pdf PDF
RFP Attachment 2A - Site Visit Campus Map - Milwaukee.pdf PDF
RFP Attachment 5 - Specs 695-21-700 Part 1.pdf PDF
RFP Attachment 8 - Drawings 695-21-700 Part 1.pdf PDF
RFP Attachment 11 - Drawings 695-21-700 Part 4.pdf PDF
RFP Attachment 13 - Drawings 695-21-700 Part 6.pdf PDF
RFP Attachment 18 - Drawings 695-21-700 Part 11.pdf PDF
RFP Attachment 20 - Drawings 695-21-700 Part 13.pdf PDF
RFP Attachment 22 - Drawings 695-21-700 Part 15.pdf PDF
RFP Attachment 28 - Drawings 695-21-700 Part 21.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BARRIER LEGEND

LIFE SAFETY LEGEND

UNDER CONSTRUCTION

ITIT

IT

IT

PULMONARY

CSS

CODE SUMMARY LIFE SAFETY NOTES

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

111-GC105

TELECOMMUNICATIONS

RM.

AREA OF WORK

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

7. COORDINATE ALL ICRA-RELATED ACTIVITIES WITH COR PRIOR

TO PERFORMANCE OF ANY WORK.

0' 15' 30' 60'

Graphic Scale : 1" = 30'-0"

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a le

/1

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:2

P

M

BUILDING 111 FIFTH FLOOR LIFE SAFETY PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

111-GC105

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1" = 30'-0"

BUILDING 111 LEVEL 05 FLOOR LIFE SAFETY PLAN

1/4" = 1'-0"

BUILDING 111 LEVEL 05 FLOOR

LIFE SAFETY PLAN - RM. 5311

1. FULLY SPRINKLERED

2. HEALTHCARE OCCUPANCY

3. SQUARE FOOTAGE: 61, 851

NTS

111 LEVEL 05 - KEY PLAN

Revisions: Date:

IT

IT

RAMP UP

FD

2 LOCKERS

DN

CSS

CODE SUMMARY LIFE SAFETY NOTES

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

111-GC106

6410A

TELECOMMUNICATIONS

RM.

AREA OF WORK

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

7. COORDINATE ALL ICRA-RELATED ACTIVITIES WITH COR PRIOR

TO PERFORMANCE OF ANY WORK.

0' 15' 30' 60'

Graphic Scale : 1" = 30'-0"

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:2

P

M

BUILDING 111 SIXTH FLOOR LIFE SAFETY PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

111-GC106

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

3/64" = 1'-0"

BUILDING 111 LEVEL 06 FLOOR LIFE SAFETY PLAN

1/4" = 1'-0"

BUILDING 111 LEVEL 06 FLOOR

LIFE SAFETY PLAN - RM. 6410A

1. FULLY SPRINKLERED

2. HEALTHCARE OCCUPANCY

3. SQUARE FOOTAGE: 58,706

NTS

111 LEVEL 06 - KEY PLAN

IT

IT

IT

UP

TYP.

UP

ROOF

WINDOWS CAN'T

SEE FROM

INSIDE ROOM

WINDOWS CAN'T

SEE FROM

INSIDE ROOM

WINDOWS CAN'T

SEE FROM

INSIDE ROOM

WINDOWS CAN'T

SEE FROM

INSIDE ROOM

C S

S

CODE SUMMARY LIFE SAFETY NOTES

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

111-GC107

TELECOMMUNICATIONS

RM.

AREA OF WORK

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

7. COORDINATE ALL ICRA-RELATED ACTIVITIES WITH COR PRIOR

TO PERFORMANCE OF ANY WORK.

0' 15' 30' 60'

Graphic Scale : 1" = 30'-0"

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:3

P

M

BUILDING 111 SEVENTH FLOOR LIFE SAFETY

PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

111-GC107

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1" = 30'-0"

BUILDING 111 LEVEL 07 FLOOR LIFE SAFETY PLAN

1/4" = 1'-0"

BUILDING 111 LEVEL 07 FLOOR

LIFE SAFETY PLAN - RM. 7412

1. FULLY SPRINKLERED

2. HEALTHCARE OCCUPANCY

3. SQUARE FOOTAGE: 58,872

NTS

111 LEVEL 07 - KEY PLAN

C S

S

IT

IT

IT

IT

IT

IT

IT

DN

C S

S

CODE SUMMARY LIFE SAFETY NOTES

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

111-GC108

TELECOMMUNICATIONS

RM.

AREA OF WORK

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

7. COORDINATE ALL ICRA-RELATED ACTIVITIES WITH COR PRIOR

TO PERFORMANCE OF ANY WORK.

0' 15' 30' 60'

Graphic Scale : 1" = 30'-0"

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:3

P

M

BUILDING 111 EIGHT FLOOR LIFE SAFETY PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

111-GC108

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1" = 30'-0"

BUILDING 111 LEVEL 08 FLOOR LIFE SAFETY PLAN

1/4" = 1'-0"

BUILDING 111 LEVEL 08 FLOOR

LIFE SAFETY PLAN - RM. 8409

1. FULLY SPRINKLERED

2. AMBULATORY HEALTHCARE OCCUPANCY

3. SQUARE FOOTAGE: 58,872

NTS

111 LEVEL 08 - KEY PLAN

IT IT

IT IT

P N E U M A T I C T U B E

PATIO

P N E U M A T I C T U B E

RAMP DN

CODE SUMMARY LIFE SAFETY NOTES

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

111-GC109

TELECOMMUNICATIONS

RM.

AREA OF WORK

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

7. COORDINATE ALL ICRA-RELATED ACTIVITIES WITH COR PRIOR

TO PERFORMANCE OF ANY WORK.

0' 15' 30' 60'

Graphic Scale : 1" = 30'-0"

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:3

P

M

BUILDING 111 NINTH FLOOR LIFE SAFETY PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

111-GC109

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1" = 30'-0"

BUILDING 111 LEVEL 09 FLOOR LIFE SAFETY PLAN

1/4" = 1'-0"

BUILDING 111 LEVEL 09 FLOOR

LIFE SAFETY PLAN - RM. 9409

1. FULLY SPRINKLERED

2. HEALTHCARE OCCUPANCY

3. SQUARE FOOTAGE: 51,744

NTS

111 LEVEL 09 - KEY PLAN

ITIT

IT

IT

WOOD

METAL DOOR

IN WALL

DN

DN C

S

S

CODE SUMMARY LIFE SAFETY NOTES

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

111-GC110

10409

TELECOMMUNICATIONS

RM.

AREA OF WORK

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

7. COORDINATE ALL ICRA-RELATED ACTIVITIES WITH COR PRIOR

TO PERFORMANCE OF ANY WORK.

0' 15' 30' 60'

Graphic Scale : 1" = 30'-0"

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:4

P

M

BUILDING 111 TENTH FLOOR LIFE SAFETY PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

111-GC110

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1" = 30'-0"

BUILDING 111 LEVEL 10 FLOOR LIFE SAFETY PLAN

1/4" = 1'-0"

BUILDING 111 LEVEL 10 FLOOR

LIFE SAFETY PLAN - RM. 10409

1. FULLY SPRINKLERED

2. BUSINESS OCCUPANCY

3. SQUARE FOOTAGE: 51,744

NTS

111 LEVEL 10 - KEY PLAN

LIFE SAFETY NOTES

BARRIER LEGEND

REVERSE OSMOSIS TANK

SURGE TANK

DEAERATOR TANK

UP DN

DN

UP

DN

UP

DN

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

EXISTING

TELECOMMUNICATION

RM.

0' 40'20'10'

Graphic Scale : 1" = 20'-0"

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:4

P

M

BUILDING 112 FIRST FLOOR LIFE SAFETY PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

112-GC101

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1/8" = 1'-0"

BUILDING 112 LEVEL 01 LIFE SAFETY PLAN

BARRIER LEGEND LIFE SAFETY NOTES

CONCRETE

PAD

CONCRETE

PAD

CONCRETE

PAD

CONCRETE

PAD

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

SWITCHGEAR ROOM

LOCKER

BATH

REFRIGERATION ROOM

STAIR

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:4

P

M

BUILDING 113 GROUND FLOOR LIFE SAFETY

PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

113-GC101

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1/8" = 1'-0"

BUILDING 113 GROUND FLOOR LIFE SAFETY PLAN

BARRIER LEGEND

C S

S

CSS

CSS

C S

S

C S

S

A

B

C

D

E

OV E R H E A D D OO R

L O U V E R WI N D O W

L O U V E R WI N D O W

A

B

C

D

E

OV E R H E A D D OO R

L O U V E R WI N D O W

L O U V E R WI N D O W

C S

S

CSS

C S

S

CSS

CODE SUMMARY

C S

S

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

123-GC101

123-GC101

123-GC101

123-GC101

123-GC101

D113

TELECOMMUNICATIONS

RM.

C113

TELECOMMUNICATIONS

RM.

B113

TELECOMMUNICATIONS

RM.

A107

TELECOMMUNICATIONS

RM.

AREA OF WORK

A

B

C

D

E

E105E

TELECOMMUNICATIONS

RM.

0' 15' 30' 60'

Graphic Scale : 1" = 30'-0"

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:5

P

M

BUILDING 123 FIRST FLOOR LIFE SAFETY PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

123-GC101

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1" = 30'-0"

BUILDING 123 LEVEL 01 LIFE SAFETY PLAN

1/4" = 1'-0"

BUILDING 123 RM. D113 ENLARGED

LIFE SAFETY PLAN

1/4" = 1'-0"

BUILDING 123 RM. C113 ENLARGED

LIFE SAFETY PLAN

1/4" = 1'-0"

BUILDING 123 RM. 113 ENLARGED

LIFE SAFETY PLAN

1/4" = 1'-0"

BUILDING 123 RM. A113 ENLARGED

LIFE SAFETY PLAN

1. FULLY SPRINKLERED

2. DORMITORY OCCUPANCY

3. SQUARE FOOTAGE: 106,646

NTS

123 KEY PLAN

1/4" = 1'-0"

BUILDING 123 LEVEL 01 LIFE SAFETY PLAN - E105E

LIFE SAFETY NOTES

AT D IS 1 7' 7' '

AT D IS 1 4' 4' '

PN EU MAT I C T U BE

TO

B

U

IL

D

IN

G

OVER H E AD D OO R W I N D OW

UNDER CONSTRUCTION

C S

S

CSS

CSS

C S

S

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

144-GC100

144-GC100

TELECOMMUNICATIONS

RM.

G68

TELEPHONE RM.

G22

G22

TELEPHONE RM.

G68

TELECOMMUNICATIONS

RM.

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:5

P

M

BUILDING 144 BASEMENT - LIFE SAFETY PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

144-GC100

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1" = 20'-0"

BUILDING 144 LEVEL 00 FLOOR LIFE SAFETY PLAN

1/4" = 1'-0"

BUILDING 144 LEVEL 00 FLOOR LIFE SAFETY PLAN - Callout 1

1/4" = 1'-0"

BUILDING 144 LEVEL 00 FLOOR LIFE SAFETY PLAN - Callout 2

LIFE SAFETY LEGEND

PN EU MAT I C T U BE

UNDER CONSTRUCTION

C S

S

CSS

C S

S

CSS

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

144-GC101

144-GC101

TELECOMMUNICATIONS

RM.

TELECOMMUNICATIONS

RM.

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:0

P

M

BUILDING 144 LEVEL 01 - LIFE SAFETY PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

144-GC101

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1" = 20'-0"

BUILDING 144 LEVEL 01 FLOOR LIFE SAFETY PLAN

1/4" = 1'-0"

BUILDING 144 LEVEL 01 FLOOR LIFE SAFETY PLAN - Callout 1

1/4" = 1'-0"

BUILDING 144 LEVEL 01 FLOOR LIFE SAFETY PLAN - Callout 2

MER

IT

ELECTRICAL

MER

003EC

CSS

IT

CSS

LIFE SAFETY LEGEND

LIFE SAFETY NOTES

BARRIER LEGEND

EXISTING TELECOM

TELECOMMUNICATIONS ROOM

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:0

P

M

BUILDING 146 BASEMENT FLOOR LIFE SAFETY

PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

146-GC101

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1/4" = 1'-0"

BUILDING 146 BASEMENT FLOOR LIFE SAFETY PLAN

1/2" = 1'-0"

BUILDING 146 BASEMENT LIFE SAFETY PLAN

CSS

LIFE SAFETY NOTES

LIFE SAFETY LEGEND

TELECOMMUNICATIONS

RM.

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:0

P

M

BUILDING 147 BASEMENT FLOOR LIFE SAFETY

PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

147-GC100

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1/4" = 1'-0"

BUILDING 147 BASEMENT LIFE SAFETY FLOOR PLAN

CSS

IT

CSS

BARRIER LEGEND LIFE SAFETY NOTES

LIFE SAFETY LEGEND

TELECOMMUNICATIONS

RM.

TELECOMMUNICATIONS

RM.

FB1 = EXISTING FIRE BARRIER 1HR (WALL TYPE R2,R3,R4,R5)

NON-RATED INTERIOR PARTITION WALL (WITH INSULATION)

EXISTING WALL TO REMAIN

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13 AND IS

PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION SYSTEM.

3. WALL TYPES ARE DETAILED ON GC102.

4. REFER TO THIS DRAWING FOR MEANS OF EGRESS.

5. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

6. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE MARSHALL.

FIRE EXTINGUISHER

F

EXIT

FIRE ALARM - MANUAL PULL STATION

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER

HAZARDOUS ROOM ENCLOSURE

SMOKE ZONE BARRIER

2 HOUR FIRE/SMOKE

ZONE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

NON-RATED SMOKE ZONE

PARTITION

HEALTH CARE OCCUPANCY

CORRIDORS

NON-RATED SMOKE

(COMMUNICATING SPACE)

SPRINKLER AND FIRE ALARM

ZONE BOUNDARY

SMOKE RESISTIVE

HAZARDOUS ROOM ENCLOSURE

EXIT STAIRWELL/PASSAGEWAY

SUITE DESIGNATION

AREA OPEN TO CORRIDOR NO

SMOKE DETECTION REQUIRED

AREA OPEN TO CORRIDOR WITH

SMOKE DETECTION

EP EXIT PASSAGEWAY

LC LINEN CHUTE

TC TRASH CHUTE

EX EXIT

HE HORIZONTAL EXIT PASSAGEWAY

EMERGENCY LIGHT

ILLUMINATED EXIT SIGN / DIRECTION

MAXIMUM TRAVEL DISTANCE

X'-X"

EGRESS DIRECTIONAL ARROW

TRAVEL DISTANCE START CIRCLE

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3 /2

:3

:1

P

M

BUILDING 148 BASEMENT LIFE SAFETY PLAN

RCO EM

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

148-GC101

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1/4" = 1'-0"

BUILDING 148 BASEMENT LIFE SAFETY PLAN

1/2" = 1'-0"

BUILDING 148 BASEMENT LIFE SAFETY PLAN - Callout 1

File details come from the government source that posted it. Updated .