695-21-700 FIRE X Full - 7-10-26.pdf
PDF 16 MB Posted
- Solicitation number
- 36C77626R0002
About this file
This document comprises final bid architectural and engineering drawings for fire protection system infrastructure upgrades at the Milwaukee VA facility, specifically detailing demolition and installation work across multiple buildings and levels.
The scope of work includes fire sprinkler system demolition and reconfiguration across seven buildings (Buildings 05, 06, 07, 20, 43, 70, 97, 102, 109, 111, and 123) at the VA Medical Center located at 5000 W. National Avenue in Milwaukee, Wisconsin. The project requires contractors to remove existing sprinkler heads, fittings, and pipe sections as needed and install new branch piping and sprinkler heads in compliance with VA standards and NFPA 13 requirements for Ordinary Hazard Group 1 occupancy. Key areas requiring reconfiguration include telecommunications rooms, storage areas, and other designated spaces shown cross-hatched on floor plans at various levels (basement through Level 10 in some buildings). The contractor must coordinate system shutdowns, fire watch procedures, and demolition activities with NFPA requirements and VA site specifications. All work must be installed per manufacturer guidelines and applicable codes, with the contractor responsible for field verification of dimensions, coordination with other trades, protection of existing equipment, infill and repair of wall/floor/ceiling penetrations, and removal of all demolished materials from the site. The drawings reference NFPA 2001 compliance for clean agent fire suppression systems in certain telecommunications rooms planned as ANSI/TIA-942-B Rating 1 facilities. Professional engineer stamps and revision documentation are dated September 5, 2025.
View the file
Other files
Show 40 more
Latest 50 of 60 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BLOCKED
KEY NOTES #
06-FD101
06-FD101
06-FD101
STORAGE
6-1-C012
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER
DEMOLITION WORK. COORDINATE DEMOLITION OF EXISTING SYSTEM BRANCHES
WITH NFPA AND VA REQUIREMENTS.
OI&T CLOSET
A104
VACANT OFFICE
B103
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:1
P
M
BUILDING 06 LEVEL 01 - FIRE PROTECTION
DEMOLITION PLAN PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
06-FD101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/16" = 1'-0"
BUILDING 06 LEVEL 01 FLOOR PLAN - FIRE PROTECTION DEMOLITION
1/4" = 1'-0"
RM 6-1-C-012 ENLARGED PLAN - FIRE PROTECTION DEMOLITION
1/4" = 1'-0"
RM A104 ENLARGED PLAN - FIRE PROTECTION DEMOLITION
1/4" = 1'-0"
RM. B103 ENLARGED PLAN - FIRE PROTECTION DEMOLITION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
IOWA
9/5/25
UP
06-FD102
TELECOMMUNICATION ROOM
D206
OFFICE
D203
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER
DEMOLITION WORK. COORDINATE DEMOLITION OF EXISTING SYSTEM BRANCHES
WITH NFPA AND VA REQUIREMENTS.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:2
P
M
BUILDING 06 LEVEL 02 - FIRE PROTECTION
DEMOLITION PLAN PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
06-FD102
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/16" = 1'-0"
BUILDING 06 LEVEL 02 FLOOR PLAN - FIRE PROTECTION DEMOLITION
3/8" = 1'-0"
ENLARGED PLAN - FIRE PROTECTION DEMOLITION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
DN
DN
DN
KEY NOTES #
06-FD103
2 VACANT
C302
VACANT
C302
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER
DEMOLITION WORK. COORDINATE DEMOLITION OF EXISTING SYSTEM BRANCHES
WITH NFPA AND VA REQUIREMENTS.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:2
P
M
BUILDING 06 LEVEL 03 - FIRE PROTECTION
DEMOLITION PLAN PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
06-FD103
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/8" = 1'-0"
BUILDING 06 LEVEL 03 FLOOR PLAN - FIRE PROTECTION DEMOLITION
1/2" = 1'-0"
ENLARGED PLAN - FIRE PROTECTION DEMOLITION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
FEC
FEC
06-FP101
06-FP101
06-FP101
STORAGE
6-1-C012
1. RECONFIGURE PIPING AND INSTALL SPRINKLER HEADS IN THIS AREA PER VA
STANDARDS AND NFPA 13 ORDINARY HAZARD GROUP 1 OCCUPANCY.
TR
A104
TR
B103
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:2
P
M
BUILDING 06 LEVEL 01 - FIRE PROTECTION
FLOOR PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
06-FP101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/16" = 1'-0"
BUILDING 06 LEVEL 01 FLOOR PLAN - FIRE PROTECTION
1/4" = 1'-0"
RM 6-1-C-012 ENLARGED PLAN - FIRE PROTECTION
1/4" = 1'-0"
RM. A104 ENLARGED PLAN - FIRE PROTECTION
1/4" = 1'-0"
RM. B103 ENLARGED PLAN - FIRE PROTECTION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
06-FP102
D203
TR1
CLOSET
D206
1. RECONFIGURE PIPING AND INSTALL SPRINKLER HEADS IN THIS AREA PER VA
STANDARDS AND NFPA 13 ORDINARY HAZARD GROUP 1 OCCUPANCY.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:3
P
M
BUILDING 06 LEVEL 02 - FIRE PROTECTION
FLOOR PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
06-FP102
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/16" = 1'-0"
BUILDING 06 LEVEL 02 FLOOR PLAN - FIRE PROTECTION
3/8" = 1'-0"
ENLARGED PLAN - FIRE PROTECTION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
DN
DN
DN
KEY NOTES #
06-FP103
VACANT
C302
1. RECONFIGURE PIPING AND INSTALL SPRINKLER HEADS IN THIS AREA PER VA
STANDARDS AND NFPA 13 ORDINARY HAZARD GROUP 1 OCCUPANCY.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:3
P
M
BUILDING 06 LEVEL 03 - FIRE PROTECTION
FLOOR PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
06-FP103
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/8" = 1'-0"
BUILDING 06 LEVEL 03 PLAN - FIRE PROTECTION
1/2" = 1'-0"
ENLARGED PLAN - FIRE PROTECTION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
TELECOMMUNICATION ROOM
B09
07-FD101
B09
TR
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER
DEMOLITION WORK. COORDINATE SYSTEM SHUT DOWN, FIRE WATCH, AND
DEMOLITION WITH NFPA REQUIREMENTS AND VA SITE REQUIREMENTS. REMOVE
EXISTING SPRINKLER HEADS, FITTINGS, AND SHORT SECTIONS OF PIPE AS
NEEDED FOR INSTALLATION OF NEW BRANCH PIPE AND SPRINKLER HEADS.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:3
P
M
BUILDING 07 BASEMENT - FIRE PROTECTION
DEMOLITION PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
07-FD101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
3/16" = 1'-0"
BUILDING 07 BASEMENT FLOOR PLAN - FIRE PROTECTION DEMOLITION
1/2" = 1'-0"
ENLARGED PLAN - FIRE PROTECTION DEMOLITION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
B09
TR
TELECOMMUNICATION ROOM
B09
07-FP101
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER WORK.
RECONFIGURE PIPING FOR PROPER HEAD PLACEMENT & INSTALL UPRIGHT
SPRINKLER HEADS IN THIS AREA PER NFPA 13 ORDINARY HAZARD GROUP 1
OCCUPANCY. DO NOT PLACE SPRINKLER HEADS ABOVE IT OR ELECTRICAL
EQUIPMENT. ROOM PLANNED AS ANSI/TIA-942-B RATING 1.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:4
P
M
BUILDING 07 BASEMENT - FIRE PROTECTION
FLOOR PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
07-FP101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/2" = 1'-0"
ENLARGED PLAN - FIRE PROTECTION
3/16" = 1'-0"
BUILDING 07 BASEMENT PLAN - FIRE PROTECTION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
ROOF
OVER HEAD DOOR
OVER HEAD DOOR
KEY NOTES #
43-FD101
MAIL/WORK
A156
TELE
A157A
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER
DEMOLITION WORK. COORDINATE SYSTEM SHUT DOWN, FIRE WATCH, AND
DEMOLITION WITH NFPA REQUIREMENTS AND VA SITE REQUIREMENTS. REMOVE
EXISTING SPRINKLER HEADS, FITTINGS, AND SHORT SECTIONS OF PIPE, AS
NEEDED FOR INSTALLATION OF NEW BRANCH PIPE AND SPRINKLER HEADS.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:4
P
M
BUILDING 43 LEVEL 01 FIRE PROTECTION
DEMOLITION PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
43-FD101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/8" = 1'-0"
BUILDING 43 LEVEL 01 FLOOR PLAN - FIRE PROTECTION DEMOLITION
1/2" = 1'-0"
ENLARGED PLAN - FIRE PROTECTION DEMOLITION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
43-FD102
LAUNDRY
A203
TELECOMMUNICATIONS ROOM
A201
STORAGE
A202
LAUNDRY
A203
STORAGE
A202
TELECOMMUNICATIONS ROOM
A201
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER
DEMOLITION WORK. COORDINATE SYSTEM SHUT DOWN, FIRE WATCH, AND
DEMOLITION WITH NFPA REQUIREMENTS AND VA SITE REQUIREMENTS. REMOVE
EXISTING SPRINKLER HEADS, FITTINGS, AND SHORT SECTIONS OF PIPE, AS
NEEDED FOR INSTALLATION OF NEW BRANCH PIPE AND SPRINKLER HEADS.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:4
P
M
BUILDING 43 LEVEL 02 FIRE PROTECTION
DEMOLITION PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
43-FD102
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/8" = 1'-0"
BUILDING 43 LEVEL 02 FLOOR PLAN - FIRE PROTECTION
1/2" = 1'-0"
ENLARGED PLAN - FIRE PROTECTION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
ROOF
OVER HEAD DOOR
OVER HEAD DOOR
KEY NOTES #
43-FP101
A156
TR
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER WORK.
RECONFIGURE PIPING FOR PROPER HEAD PLACEMENT & INSTALL UPRIGHT
SPRINKLER HEADS IN THIS AREA PER NFPA 13 ORDINARY HAZARD GROUP 1
OCCUPANCY. DO NOT PLACE SPRINKLER HEADS ABOVE IT OR ELECTRICAL
EQUIPMENT. ROOM PLANNED AS ANSI/TIA-942-B RATING 1.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:4
P
M
BUILDING 43 LEVEL 01 - FIRE PROTECTION
FLOOR PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
43-FP101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/8" = 1'-0"
BUILDING 43 LEVEL 01 PLAN - FIRE PROTECTION
1/2" = 1'-0"
ENLARGED PLAN - FIRE PROTECTION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
43-FP102
TR
A201
A201
TR
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER WORK.
RECONFIGURE PIPING FOR PROPER HEAD PLACEMENT & INSTALL UPRIGHT
SPRINKLER HEADS IN THIS AREA PER NFPA 13 ORDINARY HAZARD GROUP 1
OCCUPANCY. DO NOT PLACE SPRINKLER HEADS ABOVE IT OR ELECTRICAL
EQUIPMENT. ROOM PLANNED AS ANSI/TIA-942-B RATING 1.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:5
P
M
BUILDING 43 LEVEL 02 - FIRE PROTECTION
FLOOR PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
43-FP102
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/8" = 1'-0"
BUILDING 43 LEVEL 02 PLAN - FIRE PROTECTION
1/2" = 1'-0"
ENLARGED PLAN - FIRE PROTECTION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
C-103AC-100A
UP DN RAMP
ELECTRICAL PANEL
I C E MAKI N G M/ C
L O
C K
E R
S
LO
CKE
RS
LOCKER LOCKER
KEY NOTES #
70-FD101
E B C D
1HAC STORAGE
E-104
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER
DEMOLITION WORK. COORDINATE DEMOLITION OF EXISTING SYSTEM BRANCHES
WITH NFPA AND VA REQUIREMENTS.
0' 40'20'10'
Graphic Scale : 1" = 20'-0"
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:5
P
M
BUILDING 70 ENLARGED PLANS - FIRE
PROTECTION DEMOLITION PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
70-FD101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1" = 20'-0"
BUILDING 70 LEVEL 01 FLOOR PLAN - FIRE PROTECTION DEMOLITION
1/4" = 1'-0"
BUILDING 70 LEVEL 01 E-104HC ENLARGED PLAN -
FIRE PROTECTION DEMOLITION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
C-103AC-100A
UP DN RAMP
ELECTRICAL PANEL
I C E MAKI N G M/ C
L O
C K
E R
S
LO
CKE
RS
LOCKER LOCKER
KEY NOTES #
70-FP101
E B C D
TELECOMMUNICATONS ROOM
E-104
1. RECONFIGURE PIPING AND INSTALL SPRINKLER HEADS IN THIS AREA PER VA
STANDARDS AND NFPA 13 ORDINARY HAZARD GROUP 1 OCCUPANCY.
0' 40'20'10'
Graphic Scale : 1" = 20'-0"
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:5
P
M
BUILDING 70 ENLARGED PLANS - FIRE
PROTECTION FLOOR PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
70-FP101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1" = 20'-0"
BUILDING 70 LEVEL 01 FLOOR PLAN - FIRE PROTECTION
1/4" = 1'-0"
BUILDING 70 LEVEL 01 E-104 ENLARGED PLAN -
FIRE PROTECTION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
PAINT STORAGE
TR
KITCHEN/MAIL
WORK SHOP
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER
DEMOLITION WORK. COORDINATE SYSTEM SHUT DOWN, FIRE WATCH, AND
DEMOLITION WITH NFPA REQUIREMENTS AND VA SITE REQUIREMENTS. REMOVE
EXISTING SPRINKLER HEADS, FITTINGS, AND SHORT SECTIONS OF PIPE AS
NEEDED FOR INSTALLATION OF NEW BRANCH PIPE AND SPRINKLER HEADS.
AREA OF WORK
0' 40'20'10'
Graphic Scale : 1" = 20'-0"
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:0
P
M
BUILDING 97 ENLARGED PLANS - FIRE
PROTECTION DEMOLITION
AW DAW
FINAL BID DOCUMENTS 695-21-700EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
97-FD101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/4" = 1'-0"
BUILDING 97 LEVEL 01 FLOOR PLAN - FIRE PROTECTION DEMOLITION
NTS
KEY PLAN - BUILDING 97 KEYPLAN
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
KEYNOTES
TR
KITCHEN/MAIL
PAINT STORAGE
WORK SHOP
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER WORK.
RECONFIGURE PIPING FOR PROPER HEAD PLACEMENT & INSTALL UPRIGHT
SPRINKLER HEADS IN THIS AREA PER NFPA 13 ORDINARY HAZARD GROUP 1
OCCUPANCY. DO NOT PLACE SPRINKLER HEADS ABOVE IT OR ELECTRICAL
EQUIPMENT. ROOM PLANNED AS ANSI/TIA-942-B RATING 1.
AREA OF WORK
0' 40'20'10'
Graphic Scale : 1" = 20'-0"
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:0
P
M
BUILDING 97 ENLARGED PLANS - FIRE
PROTECTION
AW DAW
FINAL BID DOCUMENTS 695-21-700EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
97-FP101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/4" = 1'-0"
BUILDING 97 LEVEL 01 FLOOR PLAN - FIRE PROTECTION
NTS
KEY PLAN - BUILDING 97 KEYPLAN
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
GENERAL FIRE PROTECTION NOTES
GENERAL DEMOLITION NOTES
SYMBOLS - FIRE PROTECTION
AREA PLAN LEGEND
1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE DEPARTMENT OF VETERANS AFFAIRS (VA) STANDARDS.
2. DESIGN BASIS INFORMATION: PROVIDE DESIGN, MATERIALS, EQUIPMENT, INSTALLATION, INSPECTION, AND TESTING OF THE AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH THE
REQUIREMENTS OF NFPA 13.
3. ALL WORK SHALL BE IN CONFORMANCE WITH THE NFPA 13 CODE - LATEST EDITION. THE VA SERVES AS AUTHORITY HAVING JURISDICTION.
4. THESE DOCUMENTS ARE INTENDED TO COMPLY WITH APPLICABLE CODES. WHERE DISCREPANCIES OCCUR, NOTIFY THE ENGINEER/ARCHITECT IN WRITING FOR INTERPRETATION. CORRECT ANY INSTALLATION THAT FAILS TO COMPLY WITH THE CODES AND STANDARDS AT NO ADDITIONAL COST TO THE OWNER.
5. CONTRACTOR SHALL PROVIDE ALL WORK NECESSARY INCLUDING ALL LABOR, MATERIALS, PERMITS, TAXES, FEES, INSPECTIONS, HARDWARE, AND COST FOR INSTALLATION FOR A COMPLETE
AND OPERATIONAL SYSTEM.
6. ALL MATERIALS FURNISHED BY THE CONTRACTOR SHALL BE NEW, COMPLETE WITH MANUFACTURER’S GUARANTEE OR WARRANTY AND SHALL BE LISTED BY A NATIONALLY RECOGNIZED
TESTING LABORATORY.
7. PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE SEALED WITH APPROPRIATE FIRE PROOFING MATERIALS TO RESTORE FIRE RATING. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE
RATED WALLS.
8. CONTRACTOR SHALL KEEP THE WORK AREA CLEAN OF ALL DEBRIS ON A DAILY BASIS. ALL NEW MATERIALS AWAITING INSTALLATION SHALL BE KEPT IN AREAS DESIGNATED BY THE OWNER.
9. DRAWINGS SHALL NOT BE SCALED FOR DIMENSIONS. REFER TO DIMENSIONED ARCHITECTURAL FLOOR PLANS. IF THE DIMENSIONS CANNOT BE DETERMINED BY THE INFORMATION GIVEN, CONTRACTOR SHALL CONTACT THE ENGINEER FOR ADDITIONAL INFORMATION.
10. PERIODIC SITE OBSERVATION BY THE ENGINEER IS SOLELY FOR THE PURPOSE OF DETERMINING IF THE WORK OF THE CONTRACTOR IS PROCEEDING IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. THIS LIMITED SITE OBSERVATION SHOULD NOT BE CONSTRUED AS EXHAUSTIVE OR CONTINUOUS TO CHECK THE QUALITY OR QUANTITY OF THE WORK, BUT RATHER PERIODIC IN AN EFFORT TO GUARD THE OWNER AGAINST DEFECTS OR DEFICIENCIES IN THE WORK OF THE CONTRACTOR.
11. INFORMATION CONTAINED ON THE DRAWINGS IS IN ITSELF INCOMPLETE AND VOID UNLESS USED IN CONJUNCTION WITH ALL OTHER DISCIPLINE DRAWINGS, THE SPECIFICATIONS, TRADE PRACTICES, OR APPLICABLE STANDARDS, CODES, ETC., AND SHALL BE CONSIDERED THE CONTRACT DOCUMENTS AND WITH ALL THEREIN BY REFERENCE, WHICH THE CONTRACTOR CERTIFIES
KNOWLEDGE OF BY SIGNING THE CONTRACT.
12. CONTRACTOR IS TO ASSUME FULL RESPONSIBILITY, UNRELIEVED BY REVIEW OF SHOP DRAWINGS OR PERIODIC OBSERVATION OF CONSTRUCTION, FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS, FOR DIMENSIONS TO BE CONFIRMED AND CORRELATED ON THE JOB SITE AND BETWEEN INDIVIDUAL DRAWINGS OR SETS OF DRAWINGS FOR FABRICATION PROCESSES AND CONSTRUCTION TECHNIQUES (INCLUDING EXCAVATION, SHORING, SCAFFOLDING, BRACING, ERECTION, FORM WORK, ETC.), FOR COORDINATION OF THE VARIOUS TRADES, AND FOR SAFE CONDITIONS ON THE JOB SITE. VARIATIONS IN FIELD CONDITIONS RELATIVE TO THE CONTRACT DOCUMENTS SHALL BE REPORTED TO THE ENGINEER AS SOON AS THEY ARE FOUND. WORK
SHALL NOT PROGRESS UNTIL WRITTEN PERMISSION FROM THE ENGINEER IS OBTAINED.
13. ALL EQUIPMENT AND ACCESSORIES SHALL BE INSTALLED SO AS TO BE EASILY ACCESSIBLE. ALL CLEARANCES FOR EQUIPMENT PER MANUFACTURERS GUIDELINES AND CODE COMPLIANCE
SHALL BE REQUIRED.
14. PROVIDE ACCESS PANELS FOR VALVES, ETC. THAT ARE LOCATED IN CONCEALED AREAS. COORDINATE WITH GENERAL CONTRACTOR FOR EXACT LOCATION AND WITH ARCHITECTURAL PLANS
FOR FINISHES.
15. ALL COMPONENTS OF SYSTEMS SHALL BE PROVIDED FOR A COMPLETELY OPERATIONAL, UNDERSTANDABLE, SAFE, AND CLEAN SYSTEM; INCLUDING BUT NOT LIMITED TO EXTRANEOUS FIXTURE TRIM AS SPECIFIED, LABELS, SERVICE AND COMMISSIONING INTO OPERATION, TESTING AND CLEANING, FIRE AND LIFE SAFETY REQUIREMENTS, AND CONSIDERING THE REQUESTS OF OWNERS
PERSONNEL.
16. ELECTRICAL PANELS SHOWN FOR REFERENCE. DO NOT ROUTE ANY COMPONENTS ABOVE OR IN FRONT OF ELECTRICAL EQUIPMENT. MAINTAIN CODE REQUIRED CLEARANCES.
17. FIRE PROTECTION CONTRACTOR SHALL REVIEW ALL PROJECT PLANS AND SPECIFICATIONS, THEN CONTACT OWNER AND LOCAL FIRE DEPARTMENT FOR COORDINATION OF DOCUMENTATION
AND SYSTEM REQUIREMENTS PRIOR TO STARTING WORK.
18. ALL REQUIREMENTS FOR WORKING ON FIRE PROTECTION SYSTEM, INCLUDING BUT NOT LIMITED TO FIRE WATCH, HYDRANT FLOW TESTING, SYSTEM SHUTDOWNS AND TESTING, ARE THE
RESPONSIBILITY OF THE FIRE PROTECTION CONTRACTOR.
19. PLANS ARE DIAGRAMMATIC AND INTENDED TO CONVEY SCOPE OF WORK AND GENERAL LOCATIONS OF EQUIPMENT, MATERIALS, ETC. NOT ALL RISERS, DROPS, OFFSETS, VALVES, ETC. ARE SHOWN. PROVIDE RISERS, DROPS, OFFSETS, VALVES, ETC. AS REQUIRED TO MEET SPACE REQUIREMENTS AND TO AVOID INTERFERENCES WITH OTHER TRADES. MAKE FINAL CONNECTIONS TO
FIXTURES, EQUIPMENT, ETC. AS REQUIRED AND/OR PER MANUFACTURER'S RECOMMENDATIONS.
20. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND LAYOUT OWN WORK ACCORDINGLY AND IS RESPONSIBLE FOR DETERMINING EXACT LOCATIONS FOR EQUIPMENT, MATERIALS, ETC.
21. THE EXISTING SPRINKLER SYSTEM SHALL BE MODIFIED PER SPECIFIED PLANS AND SPECIFICATIONS. FIELD VERIFY EXISTING SPRINKLER SYSTEM REQUIREMENTS PRIOR TO BIDDING.
22. COORDINATE SCOPE OF WORK WITH THE WORK OF OTHER TRADES PRIOR TO INSTALLATION. ISSUES DUE TO LACK OF COORDINATION EFFORT WILL BE CORRECTED AT NO ADDITIONAL COST TO
THE OWNER.
23. COORDINATE LOCATION OF SYSTEM COMPONENTS WITHIN LIMITS OF STRUCTURE AND OTHER ENGINEERED SYSTEMS. ROUTE ALL PIPING IN CONCEALED SPACES AND INSTALL PIPING AS HIGH AS POSSIBLE. CENTER SPRINKLER HEADS WITHIN CEILING TILES. OFFSET SYSTEMS ROUTING AS REQUIRED, PROVIDING REQUIRED MATERIALS AND DRAIN POINTS. PIPE SHALL NOT BE ROUTED IN EXTERIOR WALLS UNLESS NOTED. COORDINATE ROUTING OF PIPING TO MAINTAIN REQUIRED SERVICE CLEARANCES AROUND ANY EQUIPMENT AND ELECTRICAL ITEMS.
24. INFILL AND REPAIR TO MATCH EXISTING CONDITIONS AT WALL, FLOOR, AND CEILING PENETRATIONS RESULTING FROM DEMOLISHED ITEMS, AND INSTALLATION OF NEW SYSTEMS. COORDINATE
WITH GENERAL CONTRACTOR FOR COVERAGE OF THIS SCOPE.
25. ALL ELEMENTS OF CONSTRUCTION SHALL BE INSTALLED BY SKILLED TRADESMEN OF THEIR PARTICULAR TRADE, AND INSTALLED IN A NEAT WORKMANLIKE MANNER KEEPING WITH THE HIGHEST
STANDARDS OF THE TRADE.
26. COORDINATE SCOPE OF WORK WITH PROJECT SCHEDULES AGREED UPON BY OWNER AND ALL CONTRACTORS.
27. REFER TO SPECIFICATION MANUAL FOR FURTHER DETAILS ABOUT DESIGN STANDARDS, PRODUCTS, DRAWINGS, SUBMITTALS, DOCUMENTATION, COORDINATION, AND INSTALLATION.
28. ONLY A SINGLE FIRE SPRINKLER ZONE SHALL BE ALLOWED TO BE NON-OPERATIONAL, ISOLATED AND DRAINED AT ANY TIME. CONTRACTOR TO PROVIDE FIRE WATCH WHEN SYSTEM IS SHUT
DOWN.
29. CONTRACTOR IS RESPONSIBLE FOR PROVIDING FP DESIGN SUBMITTAL PER NFPA 13 AND SPECIFICATION SECTION 21 13 13 TO INCLUDE NECESSARY HYDRAULIC CALCULATIONS.
1. ALL PIPING AND DUCTWORK IS SHOWN SCHEMATICALLY BASED ON EXISTING PLANS. CONTRACTORS SHALL BE RESPONSIBLE FOR COORDINATION OF VERIFYING ROUTES OF ALL EXISTING CONDITIONS AND EXISTING UTILITIES PRIOR TO BIDDING AND STARTING OF WORK. IF CONDITIONS DIFFER GREATLY CONTACT ENGINEER.
2. CONDUCT A PRECONSTRUCTION AIR AND WATER FLOW TEST OF EXISTING SYSTEMS AND MAINS SERVING EACH AREA AND FLOOR BEFORE STARTING ANY DEMOLITION WORK. SUBMIT REPORT
OF FLOWS AND FINDINGS TO ENGINEER AND OWNER.
3. COORDINATE SCHEDULE OF WORK WITH OWNER AND PROVIDE SUFFICIENT NOTICE BEFORE ANY SHUTDOWNS, TO MINIMIZE DISRUPTIONS TO ANY CONCURRENT OPERATIONS.
4. COMPLY WITH SITE SAFETY PROCEDURES OF OWNER, GENERAL CONTRACTOR, AND OSHA.
5. DEMOLISH MATERIALS, EQUIPMENT, AND ASSOCIATED SYSTEMS AS SHOWN WITHIN SCOPE OF WORK AREA AS DESIGNATED/NOTED. DEMOLISH ALL BRANCH DUCT AND PIPE, SUPPORTS, ACCESSORIES, EQUIPMENT, TERMINAL DEVICES, CONTROLS, WIRING, CONDUITS, AND ASSOCIATED ITEMS BACK TO RESPECTIVE MAINS. THEN CAP, SEAL, REPAIR, REINSULATE MAIN CONNECTIONS AS REQUIRED. NOTHING SHALL BE ABANDONED IN PLACE UNLESS NOTED OTHERWISE. REMOVE ALL DEMOLISHED ITEMS FROM SITE AND DISPOSE PROPERLY PER LOCAL LAWS.
6. HATCHED OR GRAYED OUT AREAS ARE NOT WITHIN CONTRACT BOUNDARY. COORDINATE WITH OWNER IF SUCH AREAS REQUIRE ACCESS TO COMPLETE SCOPE OF WORK, SUCH AS REMOVING A
BRANCH MAIN BACK TO LARGER MAIN TO ELIMINATE DEAD LEGS.
7. INFILL AND REPAIR TO MATCH EXISTING CONDITIONS ALL WALL, FLOOR, AND CEILING PENETRATIONS RESULTING FROM DEMOLISHED ITEMS, AND INSTALLATION OF NEW SYSTEMS. COORDINATE
WITH GENERAL CONTRACTOR FOR COVERAGE OF THIS SCOPE.
8. SAVE NOTED ITEMS FOR REUSE OR OWNERS SALVAGE. STORE NOTED ITEMS AND OTHER ITEMS IDENTIFIED BY OWNER IN OWNER’S DESIGNATED STORAGE AREA.
9. PROTECT EXISTING TO REMAIN EQUIPMENT, MATERIALS, AND SURROUND SITE FROM DAMAGE DURING DEMOLITION. REPAIRS AND REPLACEMENT OF EXISTING TO REMAIN CONDITIONS SHALL BE
THE CONTRACTOR’S RESPONSIBILITY.
10. REFER TO SPECIFICATION MANUAL FOR FURTHER DETAILS.
NOTES:
1. ADJUST SPRINKLERS AS NECESSARY TO CLEAR OBSTRUCTIONS. PROVIDE A
PIPE HANGER IF THE HORIZONTAL OFFSET LENGTH EXCEEDS 24 IN. [610mm].
2. PROVIDE LENGTH TO SUIT.
PROVIDE NEW UPRIGHT
PENDENT SPRINKER HEAD
1" x 1/2" PIPE
REDUCING COUPLING
SPRINKLER
BRANCH LINE
1/2" SCH 80 CLOSE NIPPLE
1" BLACK STEEL SCH 40
PIPING (TYP)N
O T
E
NOTE 2
?"SYS (EX) GENERAL PIPING - EXISTING TO REMAIN
?" GENERAL PIPING - TO BE DEMOLISHED
?"SYS GENERAL PIPING - NEW WORK
SYSTEM LABEL SYSTEM DESCRIPTION
FP FIRE PROTECTION - WET SYSTEM
FPD FIRE PROTECTION - DRY SYSTEMXXX SYSTEM DESCRIPTION
NEW CONNECTION TO EXISTING
DEMOLISH TO THIS POINT
BOTTOM CONNECTION
END DROP / DOWN
END UP / RISER
HEADER FLANGE CAP
PIPE END CAP
RISE / DROP IN-LINE
TEE DOWN
TEE UP
TOP CONNECTION
UP & DN / RISER
BACKFLOW PREVENTER (BFP)
BACKFLOW PREVENTER (BFP-RPZ)
CONTINUATION BREAK
COUPLING
REDUCER
MH100
MH100
DRAWING SYMBOLS
01-SF-3
08-TU-1-1
DETAIL NUMBER (VIEW # ON SHEET SHOWN)
TYPICAL UNIT NO.
BUILDING NO. WHERE EQUIPMENT IS LOCATED
EQUIPMENT ABBREVIATION (SUPPLY FAN)
ITEM NUMBER (TERMINAL UNIT NO. 1)
EQUIPMENT ABBREVIATION (TERMINAL UNIT)
SERVED BY (AIR HANDLER UNIT NO. 1)
DRAWING NUMBER ON SHEET SHOWN
BUILDING NO. WHERE EQUIPMENT IS LOCATED
SECTION NUMBER (VIEW # ON SHEET SHOWN)
DRAWING NUMBER ON SHEET SHOWN
ITEM NUMBER (SUPPLY FAN NO. 1)
AREA NOT IN CONTRACT
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:5
P
M
FIRE PROTECTION LEGENDS, SCHEDULES AND
ABBREVIATIONS
AW DAW
FINAL BID DOCUMENTS 695-21-700EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
F-001
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
SPR SPRINKLER LINE
SFPE SAFETY AND FIRE PROTECTION ENGINEER
QRS QUICK RESPONSE SPRINKLERS
PRV PRESSURE REDUCING VALVE
PD PRESSURE DROP OR DIFFERENCE
NPW NON POTABLE WATER
NOM. NOMINAL
NO NORMALLY OPEN
NIC NOT IN CONTRACT
NC NORMALLY CLOSED
FS FLOW SWITCH
FP FIRE PROTECTION
FMERC FACTORY MUTUAL ENGINEERING AND RESEARCH CORPORATION
FM FACTORY MUTUAL
FM FLOW METER
FDC FIRE DEPARTMENT (HOSE) CONNECTION
FD FLOOR DRAIN
FACSUL FIRE ALARM CERTIFICATE SERVICE
DN DOWN
DCW DOMESTIC COLD WATER
C CELSIUS
BFP REDUCED PRESSURE BACKFLOW PREVENTER
AS AUTOMATIC SPRINKLER
AG AIR GAP
SPRINKLER ABBREVIATIONS
WB WET-BULB (TEMPERATURE)
W WATTS
TSP TOTAL STATIC PRESSURE
TD TEMPERATURE DIFFERENCE
SQ M SQUARE METER
SQ FT SQUARE FOOT (FEET)
SP GR SPECIFIC GRAVITY
SCFM STANDARD CUBIC FEET PER MINUTE
SAT SUPPLY AIR TEMPERATURE
SI SQUARE INCHES
RPM REVOLUTIONS PER MINUTE
RAT RETURN AIR TEMPERATURE
PSIG POUNDS PER SQUARE INCH-GAGE
PSIA POUNDS PER SQUARE INCH ATMOSPHERE
PSI POUNDS PER SQUARE INCH
PPM PARTS PER MILLION
PA PASCAL
NPLV NON-STANDARD PART LOAD VALUE
Nm NEWTON-METER
NC NOISE CRITERIA
MTD MEAN TEMPERATURE DIFFERENCE
M/S METERS PER SECOND
MM MILLIMETER
MIN MINIMUM
MHP MOTOR HORSEPOWER
MERV MINIMUM EFFICIENCY REPORTING VALUE
MCA MULTICHANNEL ANALYZER
MCA MAXIMUM CURRENT AMPACITY
MBH 1000 BTUH
MAX MAXIMUM
M METER
LWT LEAVING WATER TEMPERATURE
LVG LEAVING
LH LATENT HEAT
LGT LEAVING GLYCOL TEMPERATURE
LF LINEAR FOOT (FEET)
LBS/HR POUNDS PER HOUR
LAT LEAVING AIR TEMPERATURE
L/S LITERS PER SECOND
L/M LITERS PER MINUTE
L/H LITERS PER HOUR
LF LINEAR FEET (FOOT)
L LITER
kWH KILOWATT HOUR kW KILOWATT kPA KILO PASCAL
KG/HR KILOGRAM PER HOUR
KG KILOGRAM
IPLV INTEGRATED PART LOAD VALUE
IN-LB INCH-POUND
IN WG INCH WATER GAUGE
IN HG INCHES OF MERCURY
IN INCHES
HZ HERTZ
HT HEIGHT
HP HORSEPOWER
GPM GALLONS PER MINUTE
GPH GALLONS PER HOUR
GPD GALLONS PER DAY
GAL GALLONS
GA GAUGE
FT-WC FEET OF WATER COLUMN
FT-LB FOOT-POUND
FT FEET
FPS FEET PER SECOND
FPM FEET PER MINUTE
F FAHRENHEIT
EWT ENTERING WATER TEMPERATURE
ESP EXTERNAL STATIC PRESSURE
ENT ENTERING
EGT ENTERING GLYCOL TEMPERATURE
EER ENERGY EFFICIENCY RATIO
EAT ENTERING AIR TEMPERATURE
DP DEWPOINT
DIA DIAMETER
DEG DEGREE
dB DECIBEL
DB DRY-BULB TEMPERATURE
COP COEFFICIENT OF PERFORMANCE
CM/S CENTIMETER PER SECOND
CM CUBIC METER
CFT CUBIC FEET
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
C CENTIGRADE (CELSIUS)
BTUH BRITISH THERMAL UNIT PER HOUR
BTU BRITISH THERMAL UNIT
BHP BRAKE HORSE POWER
APD AIR SIDE PRESSURE DROP
UNITS OF MEASURE
XFER TRANSFER
WCPU WATER-COOLED PACKAGED UNIT
VAMCS VA MASTER CONSTRUCTION SPECIFICATIONS
VAHBS VA HOSPITAL BUILDING SYSTEM
VBA VETERANS BENEFITS ADMINISTRATION
VHA VETERANS HEALTH ADMINISTRATION
VA DEPARTMENT OF VETERANS AFFAIRS
UTIL UTILITY
UPC UNIVERSAL PLUMBING CODE
UL UNDERWRITER'S LABORATORY
TEMP TEMPERATURE
TYP TYPICAL
SS STAINLESS STEEL
SPEC SPECIFICATION
SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS...
SI INTERNATIONAL SYSTEM OF UNITS
SHT SHEET
SEN SENSIBLE HEAT
SCI SPINAL CODE INJURY
SA SUPPLY AIR
RM ROOM
RO REVERSE OSMOSIS
RDS ROOM DATA SHEETS
REQD REQUIRED
RA RETURN AIR
R/E RETURN OR EXHAUST
PSS PRIMARY SECONDARY SYSTEM
PGW PROPYLENE GLYCOL-WATER SOLUTION
OR OPERATING ROOM
OD OUTSIDE DIAMETER
OC ON CENTER
OA OUTSIDE AIR
NTS NOT TO SCALE
NSPC NATIONAL STANDARD PLUMBING CODE
NOM NOMINAL
NOAA NATIONAL OCEANIC & ATMOSPHERIC ADMINISTRATION
NO NORMALLY OPEN
NIC NOT IN CONTRACT
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NFC NATIONAL FIRE CODES
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NEC NATIONAL ELECTRICAL CODE
NC NORMALLY CLOSED
NA NOT APPLICABLE (ALSO N/A)
MRI MAGNETIC RESONANCE IMAGING
MIN MINIMUM
MH MANHOLE
MER MECHANICAL EQUIPMENT ROOM
MECH MECHANICAL
MAX MAXIMUM
LPG LIQUID PROPANE GAS
ITAC INFORMATION TECHNOLOGY AIR CONDITIONING
IPC INTERNATIONAL PLUMBING CODE
ID INSIDE DIAMETER
ICU INTENSIVE CARE UNIT
I/O INPUT/OUTPUT
IESNA ILLUMINATION ENGINEERING SOCIETY OF NORTH...
IBC INTERNATIONAL BUILDING CODE
HAC HOUSEKEEPING AIDE’S CLOSET
GS GALVANIZED STEEL
GA GAUGE
EX EXISTING (OR EXIST)
EPACT ENERGY POLICY ACT
EPA ENVIROMENTAL PROTECTION AGENCY
ELEC ELECTRIC OR ELECTRICAL
EL ELEVATION
ESMT EASEMENT
ETO ETHYLENE OXIDE
EA EXHAUST AIR
DWG DRAWING
DEMO DEMOLITION
CO2 CARBON DIOXIDE
CENT CENTRIFUGAL
BMT BONE MARROW TRANSPLANT
BLDG BUILDING
ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
ASHRAE
AMERICAN SOCIETY OF HEATING REFRIGERATION AIR
CONDITIONING ENGINEERS
ASHP AIR SOURCE HEAT PUMP
ARI AIR CONDITIONING AND REFRIGERATION INSTITUTE
AMB AMBIENT
AFG ABOVE FINISHED GRADE
AFF ABOVE FINISHED FLOOR
ADA AMERICANS WITH DISABILITIES ACT
A/E ARCHITECTS AND ENGINEERS
GENERAL ABBREVIATIONS
NTS
TYPICAL UPRIGHT SPRINKLER HEAD DETAIL
BASEMENT 002 TELECOMMUNICATIONS ROOM No No 1 NONE
BUILDING 148
BASEMENT 002 TELECOMMUNICATIONS ROOM No No 1 NONE
BUILDING 147
BASEMENT 005 EXISTING TELECOMMUNICATION RM. No No 1 NONE
BUILDING 146
LEVEL 01 E105E TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 01 D113 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 01 C113 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 01 B113 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 01 A107 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
BUILDING 123
BASEMENT 106 REFRIGERATION ROOM No No 1 NONE
BUILDING 113
LEVEL 01 115 EXISTING TELECOMMUNICATION RM. No No 1 NONE
BUILDING 112
LEVEL 10 10409 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 09 9409 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 08 8409 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 07 7412 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 06 6410A TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 05 5311 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 04 4315 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 03 3308 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 02 2557 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 02 2528A TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 02 2235 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 01 1537B TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 01 1473 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 01 1472 ELECTRICAL ROOM Yes Yes 1 WS
LEVEL 01 1471 SUBSTATION ROOM Yes Yes 1 WS
LEVEL 01 1470 DEMARC ROOM Yes Yes 1 WS
LEVEL 01 1180 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
BASEMENT B0423 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
BASEMENT B0622 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
BASEMENT B0610E TELECOMMUNICATIONS ROOM Yes Yes 1 WS
BUILDING 111
BASEMENT B001 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
BUILDING 109
LEVEL 02 200 TELECOMMUNICATIONS ROOM No No 1 NONE
BUILDING 108
LEVEL 02 200 TELECOMMUNICATIONS ROOM No No 1 NONE
BUILDING 107
LEVEL 01 144 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
BASEMENT B100FC TELECOMMUNICATIONS ROOM Yes Yes 1 WS
BUILDING 102
LEVEL 01 005 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
BUILDING 97
LEVEL 01 E-104 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 01 D-125 EXISTING TELECOMMUNICATION RM. No No 1 NONE
LEVEL 01 C-126 TELECOMMUNICATIONS ROOM No No 1 NONE
LEVEL 01 B-159 TELECOMMUNICATIONS ROOM No No 1 NONE
BUILDING 70
LEVEL 02 A201 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 01 A156 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
BUILDING 43
LEVEL 01 20-1-030 TELECOMMUNICATIONS ROOM No No 1 NONE
BUILDING 20
BASEMENT B09 EXISTING TELECOMMUNICATION RM. Yes Yes 1 WS
BUILDING 07
LEVEL 03 C302 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 02 D203 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
LEVEL 01 B103 EXISTING TELECOMMUNICATION RM. Yes Yes 1 WS
LEVEL 01 A104 EXISTING TELECOMMUNICATION RM. Yes Yes 1 WS
LEVEL 01 6-1-C102 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
BUILDING 06
LEVEL 02 204 EXISTING TELECOMMUNICATION RM. Yes Yes 1 WS
LEVEL 01 117 TELECOMMUNICATIONS ROOM Yes Yes 1 WS
BUILDING 05
LEVEL 02 2110 TELECOMMUNICATIONS ROOM No No 1 NONE
BUILDING 04
LEVEL 01 1454 TELECOMMUNICATIONS ROOM No No 1 NONE
BUILDING 03
LEVEL NUMBER NAME
FIRE
PROTECTION
DEMO...
FIRE
PROTECTION
NEW REQUIRED
ANSI/TAI-942-B
RATING
FIRE
SUPPRESSION
SYSTEM TYPE
ROOMS IN SCOPE - FIRE PROTECTION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
PIPE SPACE
UNEXCAVATED SPACEUNEXCAVATED SPACE
AREA
WELL
KEY NOTES #
102-FD101
EXISTING TELECOMMUNICATIONS
ROOM
B100
6" FP (EX)
6" FP (EX)
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER
DEMOLITION WORK. COORDINATE SYSTEM SHUT DOWN, FIRE WATCH, AND
DEMOLITION WITH NFPA REQUIREMENTS AND VA SITE REQUIREMENTS. REMOVE
EXISTING SPRINKLER HEADS, FITTINGS, AND SHORT SECTIONS OF PIPE AS
NEEDED FOR INSTALLATION OF NEW BRANCH PIPE AND SPRINKLER HEADS.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:0
P
M
BUILDING 102 LEVEL 00 PLAN - FIRE
PROTECTION DEMOLITION PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
102-FD101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/8" = 1'-0"
BUILDING 102 LEVEL 00 PLAN - FIRE PROTECTION DEMOLITION
1/2" = 1'-0"
RM. B100 ENLARGED PLAN - FIRE PROTECTION DEMOLITION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
FD
FD
FD FD
FD
FD
FD
FD
FD
FD
FD
FD
KEY NOTES #
102-FD102
EMS PACKING
TELECOMMUNICATIONS ROOM
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER
DEMOLITION WORK. COORDINATE SYSTEM SHUT DOWN, FIRE WATCH, AND
DEMOLITION WITH NFPA REQUIREMENTS AND VA SITE REQUIREMENTS. REMOVE
EXISTING SPRINKLER HEADS, FITTINGS, AND SHORT SECTIONS OF PIPE AS
NEEDED FOR INSTALLATION OF NEW BRANCH PIPE AND SPRINKLER HEADS.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:0
P
M
BUILDING 102 LEVEL 01 PLAN - FIRE
PROTECTION DEMOLITION PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
102-FD102
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/8" = 1'-0"
BUILDING 102 LEVEL 01 FLOOR PLAN - FIRE PROTECTION DEMOLITION
1/4" = 1'-0"
RM 144 ENLARGED PLAN - FIRE PROTECTION DEMOLITION
# Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
PIPE SPACE
UNEXCAVATED SPACEUNEXCAVATED SPACE
AREA
WELL
KEY NOTES #
102-FP101
6" FP (EX)
6" FP (EX)
TELECOMMUNICATIONS RM.
B100
1. AREA SHOWN CROSS-HATCHED INDICATES SCOPE OF FIRE SPRINKLER WORK.
RECONFIGURE PIPING FOR PROPER HEAD PLACEMENT & INSTALL UPRIGHT
SPRINKLER HEADS IN THIS AREA PER NFPA 13 ORDINARY HAZARD GROUP 1
OCCUPANCY. DO NOT PLACE SPRINKLER HEADS ABOVE IT OR ELECTRICAL
EQUIPMENT. ROOM PLANNED AS ANSI/TIA-942-B RATING 1.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /2
.0
V A
.M W
I E
H R
M U p g ra d e
/M ilw
E H
R M
C o n s o lid a te d M o d e l (R rv t
/1
/2
:3
:1
P
M
BUILDING 102 LEVEL 00 PLAN - FIRE
PROTECTION FLOOR PLAN
AW DAW
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
102-FP101
5000 W. NATIONAL AVENUE…