These are technical specifications for the EHRM Infrastructure Upgrades project (695-21-700) at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin. The specifications cover interior construction finishes and hardware required for Tier 1 construction, including detailed requirements for wood doors, door hardware, flooring subsurface preparation, metal framing, and gypsum board installation.

Section 08 14 00 specifies interior flush wood doors with structural composite lumber cores, premium-grade white birch veneer faces, and transparent or painted finishes. Doors must comply with ANSI/WDMA standards, include fire-rated options with appropriate labeling per NFPA standards, and feature sound-rated assemblies where specified. Core requirements include 44mm thickness, Algoma Hardwoods structural composite lumber (5-ply), and factory finishing with conversion varnish or catalyzed vinyl systems. Section 08 71 00 establishes comprehensive door hardware requirements including Hager hinges (basis of design), Sargent mortise locksets with stainless steel levers, LCN closers, HES electric strikes, Pemko perimeter gasketing, and Medeco X4 SFIC cores integrated with the existing VA Milwaukee Grand Master Key System. Hardware sets (HW1-HW12) are defined for various door types, including standard locksets, card reader/electrified strikes, and anti-ligature options for behavioral health areas, with warranty periods ranging from 5 years for locks to 25 years for closers. Section 09 05 16 requires concrete floor subsurface preparation including moisture and pH testing per ASTM standards, with remedial epoxy coatings for moisture suppression and cementitious self-leveling underlayments for surface defects and levelness corrections. Section 09 22 16 specifies non-structural metal framing using ASTM C645 galvanized steel studs at 16-inch maximum on-center spacing, with detailed installation requirements for wall systems, shaft walls, and suspended ceiling systems. Section 09 29 00 requires ASTM C1396 Type X gypsum board at 5/8-inch thickness, water-resistant backing board in wet areas, and shaft wall liner panels with proper joint treatment and finishing per ASTM C840 standards.

View the file

Other files

File Type Posted
36C77626R0002 Amendment 0006.pdf PDF
695-21-700 Technical Question Tracking Sheet - Milw EHRM FINAL 7-22-26.pdf PDF
695-21-700 Amend 5 CIVIL UPDATED Narrative 2026-07-17.pdf PDF
695-21-700 Amend 5 CIVIL UPDATED full set 2026-07-17.pdf PDF
36C77626R0002 0005.docx DOCX document
695-21-700 MECH Full - 7-10-26.pdf PDF
695-21-700 Spec and Drawing Narrative 7-10-26.pdf PDF
36C77626R0002 Amendment 0004.pdf PDF
695-21-700 Tech Qtn Tracking Sheet - Milw EHRM FINAL 7-15-26.pdf PDF
695-21-700 PLUMB Full - 7-10-26.pdf PDF
695-21-700 ARCH Full - 7-10-26.pdf PDF
695-21-700 TECH Full - 7-10-26.pdf PDF
695-21-700 Specs Part 3 - 7-10-26.pdf PDF
695-21-700 Specs Part 1 - 7-10-26.pdf PDF
695-21-700 CIVIL Full - 7-10-26.pdf PDF
695-21-700 ELEC Full - 7-10-26.pdf PDF
695-21-700 FIRE X Full - 7-10-26.pdf PDF
36C77626R0002 Amendment 0003.pdf PDF
695-21-700 Site Visit Sign In Sheet 5-6-2026.pdf PDF
36C77626R0002 Amendment 0002.pdf PDF
AMENDED RFP Attachment 2 - Site Visit - Milwaukee.pdf PDF
36C77626R0002 Amendment 0001.pdf PDF
RFP 36C77626R0002.pdf PDF
RFP Attachment 27 - Drawings 695-21-700 Part 20.pdf PDF
RFP Attachment 29 - Drawings 695-21-700 Part 22.pdf PDF
RFP Attachment 3 - Division Cost Breakdown - Milwaukee.xlsx XLSX spreadsheet
RFP Attachment 19 - Drawings 695-21-700 Part 12.pdf PDF
RFP Attachment 6 - Specs 695-21-700 Part 2.pdf PDF
RFP Attachment 14 - Drawings 695-21-700 Part 7.pdf PDF
RFP Attachment 13 - Drawings 695-21-700 Part 6.pdf PDF
RFP Attachment 25 - Drawings 695-21-700 Part 18.pdf PDF
RFP Attachment 36 - PPQ.docx DOCX document
RFP Attachment 24 - Drawings 695-21-700 Part 17.pdf PDF
RFP Attachment 12 - Drawings 695-21-700 Part 5.pdf PDF
RFP Attachment 22 - Drawings 695-21-700 Part 15.pdf PDF
RFP Attachment 28 - Drawings 695-21-700 Part 21.pdf PDF
RFP Attachment 30 - Drawings 695-21-700 Part 23.pdf PDF
RFP Attachment 10 - Drawings 695-21-700 Part 3.pdf PDF
RFP Attachment 5 - Specs 695-21-700 Part 1.pdf PDF
RFP Attachment 18 - Drawings 695-21-700 Part 11.pdf PDF
RFP Attachment 8 - Drawings 695-21-700 Part 1.pdf PDF
RFP Attachment 2A - Site Visit Campus Map - Milwaukee.pdf PDF
RFP Attachment 35 - Project Information Sheet for Contractors.docx DOCX document
RFP Attachment 16 - Drawings 695-21-700 Part 9.pdf PDF
RFP Attachment 20 - Drawings 695-21-700 Part 13.pdf PDF
RFP Attachment 32 - Drawings 695-21-700 Part 25.pdf PDF
RFP Attachment 7 - Specs 695-21-700 Part 3.pdf PDF
RFP Attachment 26 - Drawings 695-21-700 Part 19.pdf PDF
RFP Attachment 9 - Drawings 695-21-700 Part 2.pdf PDF
RFP Attachment 2 - Site Visit - Milwaukee.pdf PDF
Show 40 more

Latest 50 of 60 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Milwaukee VAMC 01-01-16 695-21-700 EHRM Infrastructure Upgrades Final Bid Documents

Milwaukee, WI 53295 September 5, 2025

08 14 00 - 1

SECTION 08 14 00

INTERIOR WOOD DOORS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Interior flush wood doors painted finish.

1.2 RELATED WORK

A. Section 01 81 13, SUSTAINABLE CONSTRUCTION REQUIREMENTS: Paints and

Coatings and Composite Wood and Agrifiber VOC Limits.

B. Section 08 71 00, DOOR HARDWARE: Door Hardware including hardware location (height).

C. Section 08 11 13, HOLLOW METAL DOORS AND FRAMES: Installation of Doors.

D. Section 08 71 00, DOOR HARDWARE: Installation of Door Hardware.

1.3 APPLICABLE PUBLICATIONS

A. Comply with references to extent specified in this section.

B. American National Standards Institute/Window and Door Manufacturers

Association (ANSI/WDMA):

1. I.S. 1A-13 - Architectural Wood Flush Doors.

2. I.S. 6A-13 - Interior Architectural Stile and Rails Doors.

C. ASTM International (ASTM):

1. E90-09(2016) - Laboratory Measurements of Airborne Sound

Transmission Loss of Building Partitions and Elements.

D. National Fire Protection Association (NFPA):

1. 80-16 - Fire Doors and Other Opening Protectives.

2. 252-12 - Fire Tests of Door Assemblies.

E. UL LLC (UL):

1. 10C-09 - Positive Pressure Fire Tests of Door Assemblies.

F. Window and Door Manufacturers Association (WDMA):

1. TM 7-14 - Cycle-Slam Test.

2. TM 8-14 - Hinge Loading Test.

3. TM 10-14 - Screw Holding Capacity.

1.4 SUBMITTALS

A. Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

B. Submittal Drawings:

1. Show size, configuration, and fabrication and installation details.

2. Include details of glazing.

Milwaukee VAMC 01-01-16 695-21-700 EHRM Infrastructure Upgrades Final Bid Documents

Milwaukee, WI 53295 September 5, 2025

08 14 00 - 2

3. Indicate project specific requirements not included in

Manufacturer's Literature and Data submittal.

C. Manufacturer's Literature and Data:

1. Description of each product.

2. Fire rated doors showing conformance with NFPA 80 .

D. Samples:

1. Corner section of flush veneered door 300 mm (12 inches) square, showing details of construction, labeled to show grade and type number and conformance to specified standard.

2. Veneer sample 200 mm by 275 mm (8 inch by 11 inch) showing specified wood species sanded to receive a transparent finish. Factory finish veneer sample where the prefinished option is accepted.

E. Sustainable Construction Submittals:

1. Low Pollutant-Emitting Materials:

Show volatile organic compound types and quantities.

F. Test Reports: Indicate each product complies with specifications.

1. Screw Holding Capacity Test.

2. Cycle-Slam Test.

3. Hinge-Loading Test.

G. Operation and Maintenance Data:

1. Care instructions for each exposed finish product.

1.5 QUALITY ASSURANCE

A. Manufacturer Qualifications:

1. Regularly and presently manufactures specified products.

2. Manufactures specified products with satisfactory service on five similar installations for minimum five years.

1.6 DELIVERY

A. Deliver products in manufacturer's original sealed packaging.

1. Minimum 0.15 mm (6 mil) polyethylene bags or cardboard packaging to remain unbroken during delivery and storage.

B. Mark packaging, legibly. Indicate manufacturer's name or brand, type, color, and manufacture date.

1. Identify door opening corresponding to Door Schedule.

C. Before installation, return or dispose of products within distorted, damaged, or opened packaging. Retain packaging for door protection after installation.

Milwaukee VAMC 01-01-16 695-21-700 EHRM Infrastructure Upgrades Final Bid Documents

Milwaukee, WI 53295 September 5, 2025

08 14 00 - 3

1.7 STORAGE AND HANDLING

A. Store products indoors in dry, weathertight conditioned facility.

1. Store doors according to ANSI/WDMA I.S. 1A.

B. Protect products from damage during handling and construction operations.

1.8 FIELD CONDITIONS

A. Environment:

1. Product Temperature: Minimum 21 degrees C (70 degrees F) for minimum

48 hours before installation.

2. Work Area Ambient Temperature Range: 21 to 27 degrees C (70 to

80 degrees F) continuously, beginning 48 hours before installation.

3. Install products when building is permanently enclosed and when wet construction is completed, dried, and cured.

Comply with door manufacturer's instructions for relative humidity.

1.9 WARRANTY

A. Construction Warranty: FAR clause 52.246-21, "Warranty of

Construction."

B. Manufacturer's Warranty: Warrant interior factory finished flush wood doors against material and manufacturing defects.

1. Warranty Period: Lifetime of original installation.

PART 2 - PRODUCTS

2.1 PRODUCTS - GENERAL

A. Basis of Design: Section 09 06 00, SCHEDULE FOR FINISHES.

B. Provide each product from one manufacturer.

C. Sustainable Construction Requirements:

1. Low Pollutant-Emitting Materials: Comply with VOC limits specified in Section 01 81 13, SUSTAINABLE CONSTRUCTION REQUIREMENTS for the following products:

2. Paints and coatings.

3. Composite wood and agrifiber.

2.2 FLUSH WOOD DOORS

A. General:

1. ANSI/WDMA I.S. 1A, SCLC-5, Bonded, Heavy Duty.

2. Adhesive: Type II.

3. Core: Structural composite lumber, except when mineral core is required for fire rating.

4. Thickness: 44 mm (13/4 inches) unless otherwise shown or specified.

Milwaukee VAMC 01-01-16 695-21-700 EHRM Infrastructure Upgrades Final Bid Documents

Milwaukee, WI 53295 September 5, 2025

08 14 00 - 4

5. Basis of Design: Algoma Hardwoods structural composite lumber core –

5 ply. No stave core doors are acceptable. Clear transparent finish is required.

B. Faces:

1. ANSI/WDMA I.S. 1A.

2. One species throughout project unless scheduled or otherwise shown.

3. Transparent Finished Faces: Premium Grade. rotary cut, white birch

A Grade face veneer.

4. Match face veneers for doors for uniform effect of color and grain at joints. Provide center balance book matching veneers.

5. Door Edges: Same species as door face veneer, except maple is acceptable for stile face veneer on birch doors.

6. In existing buildings, where doors are required to have transparent finish, use wood species, grade, and assembly of face veneers to match adjacent existing doors.

7. Painted Finishes: Custom Grade, mill option close grained hardwood, premium or medium density overlay.

8. Factory sand doors for finishing.

C. Wood For Stops, Muntins and Moldings For Flush Doors Required to Have

Transparent Finish:

1. Solid wood of same species as face veneer, except maple is acceptable on birch doors.

2. Glazing:

a. On non-fire-rated doors, use applied wood stops nailed tightly on room side and attached on opposite side with flathead, countersunk wood screws, spaced approximately 125 mm (5 inches) on center.

D. Stiles and Rails:

1. Composite material having screw withdrawal force greater than minimum performance level value when tested according to WDMA TM 10.

2. Provide adequate blocking for bottom of doors having mechanically operated door bottom seal meeting or exceeding performance duty level per WDMA TM 10 for horizontal door edge screw holding.

3. Rabbeted transom meeting rail edges match face veneers of doors.

Bottom rail of transom panel match face veneer on non-rabbeted meeting rail edge.

E. Fire-Rated Wood Doors:

Milwaukee VAMC 01-01-16 695-21-700 EHRM Infrastructure Upgrades Final Bid Documents

Milwaukee, WI 53295 September 5, 2025

08 14 00 - 5

1. Fire Resistance Rating:

a. B Label: 1-1/2 hours.

b. C Label: 3/4 hour.

2. Provide 20-minute smoke-rated doors in smoke-rated barriers.

3. Labels:

a. Comply with NFPA 252, UL 10C, and labeled by qualified testing and inspection agency showing fire resistance rating.

1) Metal labels with raised or incised markings.

4. Performance Criteria for Stiles of Doors Utilizing Standard Mortise

Leaf Hinges:

a. Hinge Loading: WDMA TM 8. Average of 10 test samples for Extra

Heavy Duty doors.

b. Direct Screw Withdrawal: WDMA TM 10 for Extra Heavy Duty doors.

Average of 10 test samples using a steel, fully threaded #12 wood screw.

c. Cycle-Slam: 1,000,000 cycles with no loose hinge screws or other visible signs of failure when tested according to WDMA TM 7.

5. Hardware Reinforcement:

a. Provide fire smoke rated doors with hardware reinforcement blocking.

b. Size of lock blocks as required to secure hardware specified.

c. Top, Bottom and Intermediate Rail Blocks: Minimum 125 mm

(5 inches) by full core width.

d. Reinforcement blocking in compliance with labeling requirements.

Mineral material similar to core is not acceptable.

6. Other Core Components: Manufacturer's standard as allowed by labeling requirements.

7. Glazed Vision Panel Frame: Steel approved for use in labeled doors.

8. Astragal: Steel type for pairs of doors.

F. Smoke Barrier Doors:

1. Glazed Vision Panel Frame: Steel approved for use in labeled doors.

2. Astragal: Steel type for pairs of doors, including double egress doors.

G. Sound Rated Doors:

1. Fabricated as specified for flush wood doors with additional construction requirements to comply with specified sound transmission class (STC).

Milwaukee VAMC 01-01-16 695-21-700 EHRM Infrastructure Upgrades Final Bid Documents

Milwaukee, WI 53295 September 5, 2025

08 14 00 - 6

2. STC Rating of door assembly in place when tested according to

ASTM E90 by independent acoustical testing laboratory minimum 35.

a. Accessories:

1) Frame Gaskets and Automatic Door Bottom Seal: As specified in

Section 08 71 00, DOOR HARDWARE.

2.3 FABRICATION

A. Factory machine interior wood doors to receive hardware, bevels, undercuts, cutouts, accessories and fitting for frame.

1. Factory fit fire rated doors according to NFPA 80.

B. Rout doors for hardware using templates and location heights specified in Section 08 71 00, DOOR HARDWARE.

C. Factory fit doors to frame, bevel lock edge of doors 3 mm (1/8 inch) for each 50 mm (2 inches) of door thickness undercut where shown.

D. Clearances between Doors and Frames and Floors:

1. Fire Rated Doors: Comply with NFPA 80.

a. Doors with Automatic Bottom Seal: Maximum clearance 10 mm

(3/8 inch) at threshold.

b. Other Door Bottoms: Maximum 3 mm (1/8 inch) clearance at the jambs, heads, and meeting stiles, and a 19 mm (3/4 inch) clearance at bottom, except as otherwise specified.

2. Door Jambs, Heads, and Meeting Stiles: Maximum 3 mm (1/8 inch).

E. Provide cutouts for glazed openings.

F. Finish surfaces, including both faces, top and bottom and edges of the doors smooth to touch.

G. Identify each door on top edge.

1. Mark with stamp, brand or other indelible mark, giving manufacturer’s name, door’s trade name, construction of door, date of manufacture and quality.

2. Mark door or provide separate certification including name of inspection organization.

3. Identify door manufacturing standard, including glue type.

4. Identify veneer and quality certification.

5. Identification of preservative treatment for stile and rail doors.

2.4 FINISHES

A. Field Finished Doors: Seal top and bottom edges of doors with two coats of catalyzed polyurethane or water-resistant sealer.

B. Factory Transparent Finish:

Milwaukee VAMC 01-01-16 695-21-700 EHRM Infrastructure Upgrades Final Bid Documents

Milwaukee, WI 53295 September 5, 2025

08 14 00 - 7

1. Factory finish flush wood doors.

a. ANSI/WDMA I.S. 1A Section F-3 Finish System Descriptions for

System 5, Conversion Varnish or System 7, Catalyzed Vinyl.

b. Use stain when required to produce finish specified in Section

09 06 00, SCHEDULE FOR FINISHES.

PART 3 - EXECUTION

3.1 PREPARATION

A. Examine and verify substrate suitability for product installation.

1. Verify door frames are properly anchored.

2. Verify door frames are plumb, square, in plane, and within tolerances for door installation.

B. Protect existing construction and completed work from damage.

C. Install astragal on active leaf of pair of smoke doors and one leaf of double egress smoke doors.

3.2 INSTALLATION

A. Install products according to manufacturer's instructions and approved submittal drawings.

1. Install fire rated doors according to NFPA 80.

2. When manufacturer's instructions deviate from specifications, submit proposed resolution for Contracting Officer's Representative consideration.

3.3 PROTECTION

A. After installation, place shipping container over door and tape in place.

1. Do not apply tape to door faces and edges.

B. Provide protective covering over exposed hardware in addition to covering door.

C. Maintain covering in good condition until removal is directed by

Contracting Officer's Representative.

- - E N D - -

Milwaukee VAMC 01-01-16 695-21-700 EHRM Infrastructure Upgrades Final Bid Documents

Milwaukee, WI 53295 September 5, 2025

08 14 00 - 8

Milwaukee VAMC 03-01-24 695-21-700 EHRM Infrastructure Improvements Amendment 4 Milwaukee, WI 53295 10 July 2026

08 71 00-1

SECTION 08 71 00

DOOR HARDWARE

PART 1 - GENERAL

1.1 DESCRIPTION

Door hardware and related items necessary for complete installation and operation of doors.

1.2 RELATED WORK

Caulking: Section 07 92 00 JOINT SEALANTS.

Application of Hardware: Section 08 14 00, WOOD DOORS, Section 08 11 13, HOLLOW METAL DOORS AND FRAMES.

Painting: Section 09 91 00, PAINTING.

Card Readers: Section 28 13 00, PHYSICAL ACCESS CONTROL SYSTEMS.

Electrical: Division 26, ELECTRICAL.

Fire Detection: Section 28 31 00, FIRE DETECTION AND ALARM.

1.3 GENERAL

All hardware shall comply with ABAAS, (Architectural Barriers Act Accessibility Standard) unless specified otherwise.

Provide rated door hardware assemblies where required by most current version of the International Building Code (IBC).

Hardware for Labeled Fire Doors and Exit Doors: Conform to requirements of NFPA 80 for labeled fire doors and to NFPA 101 for exit doors, as well as to other requirements specified. Provide hardware listed by UL, except where heavier materials, large size, or better grades are specified herein under paragraph HARDWARE SETS. In lieu of UL labeling and listing, test reports from a nationally recognized testing agency may be submitted showing that hardware has been tested in accordance with UL test methods and that it conforms to NFPA requirements.

Hardware for application on metal and wood doors and frames shall be made to standard templates. Furnish templates to the fabricator of these items in sufficient time so as not to delay the construction.

The following items shall be of the same manufacturer, except as otherwise specified:

1. Mortise locksets.

2. Hinges for hollow metal and wood doors.

3. Surface applied overhead mechanical door closers.

4. Exit devices.

08 71 00-2

1.4 WARRANTY

Automatic door operators shall be subject to the terms of FAR Clause 52.246-21, except that the Warranty period shall be two years in lieu of one year for all items except as noted below:

1. Locks, latchsets, and panic hardware: 5 years.

2. Hinges: 10 Years

3. Door closers: 25 years.

1.5 MAINTENANCE MANUALS

In accordance with Section 01 00 00, GENERAL REQUIREMENTS Article titled "INSTRUCTIONS", furnish maintenance manuals and instructions on all door hardware. Provide installation instructions with the submittal documentation.

1.6 SUBMITTALS

Submittals shall be in accordance with Section 01 33 23.

Hardware Schedule: AHC certified hardware consultant to prepare and submit hardware schedule in the following form:

Hardware Item

Quantity Size Reference Publication Type No.

Finish Mfr.

Name and Catalog No.

Key Control Symbols

UL Mark (if fire rated and listed)

ANSI/BHMA

Finish Designation

Samples and Manufacturers' Literature:

1. Samples: All hardware items (proposed for the project) that have not been previously approved by Builders Hardware Manufacturers

Association shall be submitted for approval. Tag and mark all items with manufacturer's name, catalog number and project number.

2. Samples are not required for hardware listed in the specifications by manufacturer's catalog number, if the contractor proposes to use the manufacturer's product specified.

Certificate of Compliance and Test Reports: Submit certificates that hardware conforms to the requirements specified herein. Certificates shall be accompanied by copies of reports as referenced. The testing shall have been conducted either in the manufacturer's plant and certified by an independent testing laboratory or conducted in an

08 71 00-3 independent laboratory, within four years of submittal of reports for approval.

1.7 DELIVERY AND MARKING

Deliver items of hardware to job site in their original containers, complete with necessary appurtenances including screws, keys, and instructions. Tag one of each different item of hardware and deliver to

COR for reference purposes. Tag shall identify items by Project

Specification number and manufacturer's catalog number. These items shall remain on file in COR's office until all other similar items have been installed in project, at which time the COR will deliver items on file to Contractor for installation in predetermined locations on the project.

1.8 PREINSTALLATION MEETING

Convene a preinstallation meeting not less than 30 days before start of installation of door hardware. Require attendance of parties directly affecting work of this section, including Contractor and Installer, Architect, Project Engineer and VA Locksmith, Hardware Consultant, and

Hardware Manufacturer’s Representative. Review the following:

1. Inspection of door hardware.

2. Job and surface readiness.

3. Coordination with other work.

4. Protection of hardware surfaces.

5. Substrate surface protection.

6. Installation.

7. Adjusting.

8. Repair.

9. Field quality control.

10. Cleaning.

1.9 INSTRUCTIONS

Hardware Set Symbols on Drawings: Except for protective plates, door stops, mutes, thresholds and the like specified herein, hardware requirements for each door are indicated on drawings by symbols. Symbols for hardware sets consist of letters (e.g., "HW") followed by a number.

Each number designates a set of hardware items applicable to a door type.

Keying: All cylinders shall be keyed into existing Grand Master Key

System. Provide removable core cylinders that are removable only with a

08 71 00-4 special key or tool without disassembly of knob or lockset. Cylinders shall be standard pin type (7 pins) used by the Facility. Keying information shall be furnished at a later date by the COR.

1.10 APPLICABLE PUBLICATIONS

The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. In text, hardware items are referred to by series, types, etc., listed in such specifications and standards, except as otherwise specified.

ASTM International(ASTM):

F883-13.................Padlocks

American National Standards Institute/Builders Hardware Manufacturers Association (ANSI/BHMA):

A156.1-06...............Butts and Hinges

A156.2-03...............Bored and Pre-assembled Locks and Latches

A156.3-08...............Exit Devices, Coordinators, and Auto Flush Bolts

A156.4-08...............Door Controls (Closers)

A156.5-14...............Cylinders and Input Devices for Locks.

A156.6-05...............Architectural Door Trim

A156.8-05...............Door Controls-Overhead Stops and Holders

A156.11-14..............Cabinet Locks

A156.12-05 .............Interconnected Locks and Latches

A156.13-05..............Mortise Locks and Latches Series 1000

A156.14-07 .............Sliding and Folding Door Hardware

A156.15-06..............Release Devices-Closer Holder, Electromagnetic and Electromechanical

A156.16-08..............Auxiliary Hardware

A156.17-04 .............Self-Closing Hinges and Pivots

A156.18-06..............Materials and Finishes

A156.20-06 .............Strap and Tee Hinges, and Hasps

A156.21-09..............Thresholds

A156.22-05..............Door Gasketing and Edge Seal Systems

A156.23-04..............Electromagnetic Locks

A156.24-03..............Delayed Egress Locking Systems

A156.25-07 .............Electrified Locking Devices

A156.28-07 .............Master Keying Systems

A156.29-07 .............Exit Locks and Alarms

08 71 00-5

A156.30-03 .............High Security Cylinders

A156.31-07 .............Electric Strikes and Frame Mounted Actuators

A156.36-10..............Auxiliary Locks

A250.8-03...............Standard Steel Doors and Frames

National Fire Protection Association (NFPA):

80-10...................Fire Doors and Other Opening Protectives

101-09..................Life Safety Code

Underwriters Laboratories, Inc. (UL):

Building Materials Directory (2008)

PART 2 - PRODUCTS

2.1 BASIS OF DESIGN:

This schedule below summarizes the manufacturers referenced in the hardware sets and identifies whether each is a basis-of-design product, a brand-specific requirement, or a sole-source/system-compatibility item.

Basis of Design and Sole Source

Description Manufacturer Classification

Hinges Hager HG Basis of Design

Electrified hinges, and Electro Lynx harnesses

McKinney MK Basis of Design in Hardware Sets

Mechanical and electrified mortise locksets; lock power supply;

SARGENT SA Brand-Only / Sole Source or System Compatibility

Levers: 8200 Series, L lever style

SARGENT SA Basis of design/brand-only product.

Core - Medeco X4 SFIC cores, model 33N700006 or current VA-approved equivalent designation.

Medeco MC Brand-Specific / Existing-System Compatibility

Electric strikes HES HS Basis of Design in Hardware Sets

Surface, slide-track, and stop-arm closers

LCN LC Brand-Only / Sole Source

Armor plates, kick plates, wall stops, flush bolts, coordinators, and brackets

Rockwood RO Basis of Design

Perimeter gasketing and astragal seals

Pemko PE Basis of Design

Proximity card readers HID HD Brand-Specific / Existing-System Compatibility

Surface-mounted door cord

Securitron SU Basis of Design

08 71 00-6

2.2 BUTT HINGES

Comply with ANSI/BHMA A156.1, Grade 1. Provide only five-knuckle, ball-bearing butt hinges. Three-knuckle hinges are not permitted. Unless otherwise specified, provide the following hinge types for the indicated door applications:

1. Exterior Doors: Type A2112/A5112 for doors 3 feet) wide or less and Type A2111/A5111 for doors over (3 feet) wide. Hinges for exterior outswing doors shall have non-removable pins. Hinges for exterior fire-rated doors shall be of stainless-steel material.

2. Interior Doors: Type A8112/A5112 for doors (3 feet) wide or less and Type A8111/A5111 for doors over (3 feet) wide. Hinges shall be of stainless-steel material.

Provide quantity and size of hinges per door leaf as follows:

1. Doors up to 4 feet) high: 2 hinges.

2. Doors (4 feet) to (7 feet 5 inches) high: 3 hinges minimum.

3. Doors greater than 7 feet 5 inches) high: 4 hinges.

4. Doors up to(3 feet) wide, standard weight:(4-1/2 inches x 4-1/2 inches) hinges.

5. Doors over (3 feet)to(3 feet 6 inches) wide, standard weight:(5 inches x 4-1/2 inches).

6. Doors over (3 feet 6 inches) to (4 feet), heavy weight: (5 inches x 4-1/2 inches).

7. Provide heavy-weight hinges where specified.

8. At doors weighing 330 kg (150 pounds) or more, furnish (5 inch) high hinges.

See Articles "MISCELLANEOUS HARDWARE" and "HARDWARE SETS" for pivots and hinges other than butts specified above.

2.3 NOT USED

2.4 OVERHEAD MECHANICAL CLOSERS

Conform to ANSI A156.4, Grade 1.

Closers shall conform to the following:

1. The closer shall have minimum 50 percent adjustable closing force over minimum value for that closer and have adjustable hydraulic back check effective between 60 degrees and 85 degrees of door opening.

2. Where specified, closer shall have hold-open feature.

08 71 00-7

3. Size Requirements: Provide multi-size closers, sizes 1 through 6, except where multi-size closer is not available for the required application.

4. Material of closer body shall be forged or cast.

5. Arm and brackets for closers shall be steel, malleable iron or high strength ductile cast iron.

6. Where closers are exposed to the exterior or are mounted in rooms that experience high humidity, provide closer body and arm assembly of stainless steel material.

7. Closers shall have full size plastic covers.

8. Closers shall have adjustable hydraulic back-check, separate valves for closing and latching speed, adjustable back-check positioning valve, and adjustable delayed action valve.

9. Provide closers with any accessories required for the mounting application, including (but not limited to) drop plates, special soffit plates, spacers for heavy-duty parallel arm fifth screws, bull-nose or other regular arm brackets, longer or shorter arm assemblies, and special factory templating. Provide special arms, drop plates, and templating as needed to allow mounting at doors with overhead stops and/or holders.

10. Closer arms or backcheck valve shall not be used to stop the door from overswing, except in applications where a separate wall, floor, or overhead stop cannot be used.

11. Provide parallel arm closers with heavy duty rigid arm.

12. Where closers are to be installed on the push side of the door, provide parallel arm type except where conditions require use of top jamb arm.

13. Provide all surface closers with the same body attachment screw pattern for ease of replacement and maintenance.

14. All closers shall have a 1 ½” minimum piston diameter.

2.5 DOOR STOPS

Conform to ANSI A156.16.

Provide door stops wherever an opened door or any item of hardware thereon would strike a wall, column, equipment or other parts of building construction. For concrete, masonry or quarry tile construction, use expansion shields for mounting door stops.

1. NOTE: Floor Stops are not authorized for use within Milwaukee VAMC.

08 71 00-8

Where cylindrical locks with turn pieces or pushbuttons occur, equip wall bumpers Type L02251 (rubber pads having concave face) to receive turn piece or button.

Omit stops where floor mounted door holders are required and where automatic operated doors occur.

Provide appropriate roller bumper for each set of doors (except where closet doors occur) where two doors would interfere with each other in swinging.

Provide door stops on doors where combination closer magnetic holders are specified, except where wall stops cannot be used or where floor stops cannot be installed within 4-inches of the wall.

Where the specified wall or cannot be used, provide concealed overhead stops (surface-mounted where concealed cannot be used).

Provide blocking at all door stop locations to adequately support and secure door stops. Coordinate exact locations with door hardware requirements.

2.6 CORES CYLINDERS AND KEYING

Cores and Cylinders

1. Provide cylinders with interchangeable cores removable only by use of a special control key and without disassembly of knob, lever, lockset, or other lock hardware.

2. Cores shall be patented Medeco X4 SFIC and factory keyed to match and integrate with the existing VAMC Milwaukee Grand Master Key System.

Core Schedule

1. VA COR will provide keyway and series information for the

Contractor’s use in ordering cores from Medeco.

2. Keying information will be furnished to the Contractor after the core schedule has been reviewed and completed by the VA COR.

Compatibility

a. Provide interchangeable cores compatible with all core housings furnished for the Project, including mortise locks, rim locks, cylindrical locks, cabinet locks, millwork locks, padlocks, access doors, and other lock housings included in the VAMC Milwaukee

Grand Master Key System.

b. Coordinate all core housings, cylinders, and locking devices to accept the specified seven-pin SFIC cores.

Ordering and Shipping

08 71 00-9

a. Hardware Contractor shall order permanent combinated cores from Medeco using the keyway and series information provided by the VA

COR.

b. VA COR will provide a letter to Medeco authorizing cores for this Project to be shipped directly to VA Locksmith.

c. Permanent combinated cores shall be shipped directly from Medeco to VA Locksmith.

d. Provide two blank, uncut keys per permanent core, shipped directly from Medeco to the VA Locksmith with the permanent cores.

Construction Cores and Plugs

1. Cylinders provided by the Contractor shall include removable/disposable plastic construction plugs.

2. Brass/keyed construction cores required by the Contractor shall be furnished by the VA and installed by the VA Locksmith upon written notification from the Contractor.

3. Contractors shall coordinate construction core requirements, installation timing, and access needs with the VA Locksmith and COR.

Coordination

1. Contractor shall not install permanent cores unless directed by the

VA COR or VA Locksmith.

2. Coordinate final keying, permanent core delivery, construction cores, and turnover procedures with the VA COR and VA Locksmith. Permanent keying information is sensitive security information and shall be handled only as directed by the VA COR.

2.7 LOCKS AND LATCHES

Locks and latches for doors 1-3/4 inches thick or greater shall have beveled fronts. Locksets and latches shall be furnished with removable-core housings compatible with the cores and cylinders previously specified under CORES, CYLINDERS AND KEYING. Disassembly of the lever or lockset shall not be required to remove the core from the lockset.

Locksets or latches on fire-rated pairs of doors shall have latch bolts with a 3/4-inch throw, unless a shorter throw is permitted by the door manufacturer’s fire label. Provide temporary keying devices or construction cores to allow opening and closing during construction and prior to installation of final cores.

In addition to above requirements, locks and latches shall comply with following requirements:

08 71 00-10

1. Mortise Locksets and Latches: Conform to ANSI/BHMA A156.13. Mortise locksets shall be Series 1000, Grade 1, and shall accept a small format interchangeable core (SFIC). Provide Sargent 8200 Series mortise locksets and latches, lever style “L,” as basis of design. No roses accepted; provide full escutcheon only. All locksets and latchsets, except on designated doors in Psychiatric (Mental Health) areas, shall have lever handles fabricated from cast stainless steel.

No substitute lever material shall be accepted. All locksets and latchsets shall be furnished with 4-7/8 inch curved lip strike and wrought box. At outswing pairs with overlapping astragals, provide flat lip strike with 7/8 inch lip-to-center dimension. Lock function

F02 shall be furnished with emergency tools/keys for emergency entrance. All lock cases installed on lead lined doors shall be lead lined before applying final hardware finish. Furnish armored fronts for all mortise locksets. Where mortise locksets are installed in high-humidity locations or where exposed to the exterior on both sides of the opening, provide non-ferrous mortise lock case.

2. Cylindrical Locksets and Latches: Conform to ANSI/BHMA A156.2. Levers shall meet ADA requirements. Cylindrical locksets shall be Series

4000, Grade 1, and shall accept a small format interchangeable core

(SFIC). Provide lever style “L.” All locksets and latchsets shall be furnished with 4-7/8 inch curved lip strike and wrought box. At outswing pairs with overlapping astragals, provide flat lip strike with 7/8 inch lip-to-center dimension.

3. Auxiliary locks shall be as specified under hardware sets and conform to ANSI A156.36.

4. Push-Pull Latches: Push-pull latches shall conform to applicable ANSI/BHMA requirements. Locksets shall be fabricated of cast stainless steel.

5. Privacy Locksets: Privacy locksets shall include emergency release function meeting F76 ANSI requirements. Provide privacy locksets only where indicated in the hardware sets.

Basis of Design / Sole Source: VAMC Milwaukee sole sources Sargent locksets and latches, lever style “L,” Series 8200. Use Sargent as the basis of design in every hardware group requiring locksets and latches.

COR will submit Justification and Approval/Sole Source documentation for this equipment.

08 71 00-11

Deadbolts / Secondary Locking Devices: Deadbolts and other secondary locking devices shall not be provided unless specifically indicated or approved by the VA. The need for deadbolts shall be reviewed with the VA

COR, VA Police, user group, and physical security requirements. VA preference is to avoid secondary two-step locking mechanisms wherever possible, while maintaining compliance with VA Handbook 0730, Physical

Security.

2.8 KEYS

Provide two blank, uncut, unstamped zero-bitted keys per core. Cut keys specific to pinned cores are not required and shall not be provided.

2.9 ARMOR PLATES, KICK PLATES, MOP PLATES AND DOOR EDGING

Conform to ANSI Standard A156.6.

Provide protective plates and door edging as specified below:

1. Kick plates, mop plates and armor plates of metal, Type J100 series.

2. Provide kick plates and mop plates where specified. Kick plates shall be(10 inches) or (12 inches) high. Mop plates shall be (6 inches) high. Both kick and mop plates shall be minimum(0.050 inches) thick.

Provide kick and mop plates beveled on all 4 edges (B4E). On push side of doors where jamb stop extends to floor, make kick plates (1-

1/2 inches) less than width of door, except pairs of metal doors which shall have plates(1 inch) less than width of each door. Extend all other kick and mop plates to within(1/4 inch) of each edge of doors. Kick and mop plates shall butt astragals. For jamb stop requirements, see specification sections pertaining to door frames.

3. Kick plates and/or mop plates are not required on following door sides:

a. Armor plate side of doors;

b. Exterior side of exterior doors;

c. Closet side of closet doors;

d. Both sides of aluminum entrance doors.

4. Armor plates for doors are listed under Article "Hardware Sets".

Armor plates shall be thickness as noted in the hardware set,(35 inches) high and(1-1/2 inches) less than width of doors, except on pairs of metal doors. Provide armor plates beveled on all 4 edges

(B4E). Plates on pairs of metal doors shall be (1 inch) less than width of each door. Where top of intermediate rail of door is less than (35 inches) from door bottom, extend armor plates to within (1/2

08 71 00-12 inch) of top of intermediate rail. On doors equipped with panic devices, extend armor plates to within (1/2 inch) of panic bolt push bar.

5. Where louver or grille occurs in lower portion of doors, substitute stretcher plate and kick plate in place of armor plate. Size of stretcher plate and kick plate shall be (10 inches) high.

6. Provide stainless steel edge guards where so specified at wood doors.

Provide mortised type instead of surface type except where door construction and/or ratings will not allow. Provide edge guards of bevel and thickness to match wood door. Provide edge guards with factory cut-outs for door hardware that must be installed through or extend through the edge guard. Provide full-height edge guards except where door rating does not allow; in such cases, provide edge guards to height of bottom of typical lockset armor front. Forward edge guards to wood door manufacturer for factory installation on doors.

2.10 PUSH PLATES

Conform to ANSI A156.6. Metal, Type J302, (8 inches) wide by (16 inches) high. Provide metal Type J302 plates (4 inches) wide by (16 inches) high where push plates are specified for doors with stiles less than (8 inches) wide. Cut plates for cylinders and turn pieces where required.

2.11 THRESHOLDS

Conform to ANSI A156.21, mill finish extruded aluminum, except as otherwise specified. In existing construction, thresholds shall be installed in a bed of sealant with ¼-20 stainless steel machine screws and expansion shields. In new construction, embed aluminum anchors coated with epoxy in concrete to secure thresholds. Furnish thresholds for the full width of the openings.

For thresholds at elevators entrances see other sections of specifications.

At exterior doors and any interior doors exposed to moisture, provide threshold with non-slip abrasive finish.

Provide with miter returns where threshold extends more than (0.5 inch) beyond face of frame.

2.12 FINISHES

Exposed surfaces of hardware shall have ANSI A156.18, finishes as specified below. Finishes on all hinges, pivots, closers, thresholds, 08 71 00-13 etc., shall be as specified below under "Miscellaneous Finishes." For field painting (final coat) of ferrous hardware, see Section 09 91 00, PAINTING.

626 or 630: All surfaces on exterior and interior of buildings, except where other finishes are specified.

Miscellaneous Finishes:

1. Hinges 630 / US32D.

2. Pivots: Match door trim.

3. Door Closers: Factory applied paint finish. Dull or Satin Aluminum color.

4. Thresholds: Mill finish aluminum.

5. Cover plates for floor hinges and pivots: 630.

6. Other primed steel hardware: 600.

Hardware Finishes for Existing Buildings: U.S. Standard finishes shall match finishes of hardware in (similar) existing spaces except where otherwise specified.

Special Finish: Exposed surfaces of hardware for dark bronze anodized aluminum doors shall have oxidized oil rubbed bronze finish (dark bronze) finish on door closers shall closely match doors.

2.13 BASE METALS

Apply specified U.S. Standard finishes on different base metals as following:

Finish Base Metal

652 / US26D Satin Chromium plated Steel

626 / US26D Satin Chromium plated Brass or bronze

630 / US32D Satin Stainless Steel Stainless steel

PART 3 - EXECUTION

3.1 HARDWARE HEIGHTS

For existing buildings locate hardware on doors at heights to match existing hardware. The Contractor shall visit the site, verify location of existing hardware and submit locations to VA COR for approval.

Hardware Heights from Finished Floor:

1. Exit devices centerline of strike (where applicable) 40-5/16 inches).

2. Locksets and latch sets centerline of strike (40-5/16 inches).

3. Deadlocks centerline of strike (48 inches).

08 71 00-14

4. Hospital arm pull (46 inches) to centerline of bottom supporting bracket.

5. Centerline of door pulls to be(40 inches).

6. Push plates and push-pull shall be (50 inches) to top of plate.

7. Push-pull latch to be(40-5/16 inches) to centerline of strike.

8. Locate other hardware at standard commercial heights. Locate push and pull plates to prevent conflict with other hardware.

3.2 INSTALLATION

Closer devices, including those with hold-open features, shall be equipped and mounted to provide maximum door opening permitted by building construction or equipment. Closers shall be mounted on side of door inside rooms, inside stairs, and away from corridors. At exterior doors, closers shall be mounted on interior side. Where closers are mounted on doors they shall be mounted with hex nuts and bolts; foot shall be fastened to frame with machine screws.

Hinge Size Requirements:

Door Thickness Door Width Hinge Height

(1-3/4 inch) (3 feet) and less (4-1/2 inches)

(1-3/4 inch) Over (3 feet) but not more than (4 feet)

(5 inches)

(1-3/8 inch) (hollow core wood doors)

Not over (4 feet) (4-1/2 inches)

Hinge leaves shall be sufficiently wide to allow doors to swing clear of door frame trim and surrounding conditions.

Where new hinges are specified for new doors in existing frames or existing doors in new frames, sizes of new hinges shall match sizes of existing hinges; or, contractor may reuse existing hinges provided hinges are restored to satisfactory operating condition as approved by

COR. Existing hinges shall not be reused on door openings having new doors and new frames. Coordinate preparation for hinge cut-outs and screw-hole locations on doors and frames.

Hinges Required Per Door:

Door Description Number butts

Doors (5 ft) or less in height 2 butts

Doors over (5 ft) high and not over (7 ft 6 in) high 3 butts

Doors over(7 feet 6 inches) high 4 butts

08 71 00-15

Door Description Number butts

Dutch type doors 4 butts

Doors with spring hinges (4 feet 6 inches) high or less 2 butts

Doors with spring hinges over (4 feet 6 inches) 3 butts

Fastenings: Suitable size and type and shall harmonize with hardware as to material and finish. Provide machine screws and lead expansion shields to secure hardware to concrete, ceramic or quarry floor tile, or solid masonry. Fiber or rawl plugs and adhesives are not permitted. All fastenings exposed to weather shall be of nonferrous metal.

After locks have been installed; show in presence of COR that keys operate their respective locks in accordance with keying requirements.

(All keys, Master Key level and above shall be sent Registered Mail to the Medical Center Director along with the bitting list. Also a copy of the invoice shall be sent to the COR for his records.) Installation of locks which do not meet specified keying requirements shall be considered sufficient justification for rejection and replacement of all locks installed on project.

3.3 FINAL INSPECTION

Installer to provide letter to COR that upon completion, installer has visited the Project and has accomplished the following:

1. Re-adjust hardware.

2. Evaluate maintenance procedures and recommend changes or additions and instruct VA personnel.

3. Identify items that have deteriorated or failed.

4. Submit written report identifying problems.

3.4 DEMONSTRATION

Demonstrate efficacy of mechanical hardware and electrical, and electronic hardware systems, including adjustment and maintenance procedures, to satisfaction of COR and VA Locksmith.

Prior to owner’s occupancy, the general contractor shall schedule and conduct a post-installation meeting with the hardware supplier and the manufacturer representative who supplied the commercial locks, the exit devices, the door controls/closers, etc. for review of the installation of devices.

08 71 00-16

3.5 HARDWARE SETS

Following sets of hardware correspond to hardware symbols shown on drawings. Only those hardware sets that are shown on drawings will be required. Disregard hardware sets listed in specifications but not shown on drawings.

Set 2.0 Description: Card Reader x Elec Strike, Closer/Rated, Slide Track Closer

As Req'd Hinge (heavy weight) Non-Removable Pin & Ball Bearing

Hager BB1199 HG

1 Storeroom Lock 70 8204 LE1L SA

1 Small Format Inter Core 7-Pin SFIC 33700006N MC

1 Electric Strike 1006-DBM2 (as req'd) HS ⚡ 1 Closer x Slide Track 4040XPT Track Door Closer 689 LC 2 Armor Plate (UL) K1050 F 35" high CSK BEV RO 1 Perimeter Gasketing S88BL (head & jambs) PE 1 E-Lynx Harness (Frame) QC-C3000P MK ⚡ 1 Card Reader RPK-40 (By Security Vendor) BLK HD 1 Power Supply 3570 SA ⚡

Set 3.0 Description: Card Reader x Elec Strike, Closer/Rated, Slide Track Closer / Pair

As

Req'd Hinge (heavy weight) Non- Removable Pin & Ball Bearing

Hager BB1199

HG

1 Storeroom Lock 70 8204 LE1L

SA

1 Small Format Inter Core / 7-Pin SFIC

33700006N

MC

1 Electric Strike 1006-DBM2 (as req'd for pair/rated condition)

HS ⚡

1 C/L Flush Bolt w/Fire Bolt 2849

RO

1 Coordinator 2672

2 Mounting Bracket 2601AB

2 Closer x Stop 4040XP.CUSH

LC

4 Armor Plate (UL) K1050 F 35" high CSK BEV

1 Perimeter Gasketing S88BL (head & jambs)

PE

1 Astragal Seal S772BL

PE

1 E-Lynx Harness (Frame) QC-C3000P

MK ⚡

1 Card Reader RPK-40 (By Security Vendor) BLK HD

1 Power Supply 3570

SA ⚡

08 71 00-17

Set 5.0 Description: Storeroom x Closer

Non-Removable Pin & Ball Bearing

Hager BB1199 HG

1 Storeroom Lock 70 8204 LE1L SA 1 Small Format Inter Core 33700006N MC 1 Surface Closer 4040XP.RWPA LC 1 Kick Plate K1050 10" 4BE CSK RO 1 Wall Stop 402 / 405 (as req'd) RO

Set 6.0 Description: Classroom x Closer

Non-Removable Pin & Ball Bearing

Hager BB1199 HG

1 Classroom Lock 70 8237 LE1L SA 1 Small Format Inter Core 33700006N MC 1 Surface Closer 4040xp RW/PA LC 1 Kick Plate K1050 10" 4BE CSK RO 1 Wall Stop 402 / 405 (as req'd) RO

END OF SECTION 08 71 00

BASIS OF DESIGN

MILWAUKEE VA

0730/4 COMPATIBLE

HARDWARE GROUPS

9/13/2021

IF door frame cannot be changed use: HW1 – ELECTRIFIED LOCKSET HW1 cont. – ELECTRIFIED LOCKSET EQUIPMENT PER 4 TO 8 DOORS

QTY DESCRIPTION MFG FIN 1 EA POWER SUPPLY 3570 24V 6AMP SAR N/A

3 EA HINGE WTBB1191 4.5” X 4.5” HA 630 4-8 EA DOOR WIRE HARNESS TO

LOCKSET

CS443040

QC-C300, QC 12-38";

8&4P CNNCTR

MCK N/A

1 EA STORAGE NAC-82271 LNE IDP

PLUS SFIC CYLINDER

SAR 626 4-8 EA ACP WIRE HARNESS TO DOOR CS443042

QC-C1500, QC 12-15'2";

8&4P CNNCTR

MCK N/A

1 EA SMALL FORMAT

INTERCHANGEABLE CORE

33N700006 MD 626

1 EA CLOSER 4111D (PUSH SIDE, DELAY) LNC 689

2 EA ARMOR PLATE 8400 35”, UL LISTED NEEDED BY

CONDITION

IVES 630 LOW-MEDIUM ASSURANCE MultiClass RP-40 FLAT BLACK READER

1 EA STOP STOP AS NEEDED BY CONDITION,

WALL MOUNTED WITH BLOCKING

“ 626 HIGH ASSURANCE MultiClass RPK-40 WITH KEYPAD

1 EA CARD READER MultiClass RP-40 HID N/A FRAME NOTES DOOR NOTES

1 EA ARMOR CORD MCK-TSB-C

DOOR CORD, GRAY/BLACKCAPS,18"

MCK N/A FRAME CHANGES REQUIRED

WITH:

HW4

HW5

HW8

HW9

HW10

HW12

DOOR CHANGES

REQUIRED WITH:

HW1

HW2

HW4

HW5

HW7

HW8

HW9

HW10

HW12

IF door is egress and req med assurance use: HW2 – ELECTRIFIED STRIKE/EXIT DEVICE

QTY DESCRIPTION MFG FIN

3 EA HINGE BB1191 4.5” X 4.5” HA 630

1 EA SMALL FORMAT

INTERCHANGEABLE CORE

33N700006 MD 626

1 EA EXIT DEVICE 9875L-NL-F-06-3' 26D VON 26D Pull Trim (990NL) and Rim Cylinder to be included with exit device

1 EA CLOSER 4111D (PUSH SIDE, DELAY) LCN 689

1 EA STOP STOP AS NEEDED BY CONDITION “ 626

2 EA ARMOR PLATE 8400 35”, UL LISTED

NEEDED BY CONDITION

IVES 630

1 EA ELEC STRIKE 9500 SURFACE MONT FOR 3/4" RIM

EXITS

HES 630

1 EA CARD READER MultiClass RP-40 HID N/A

IF req med assurance w/exsisting hardware use: HW3 – NEW CARD READER TO BE INTERGRATED INTO EXSISTING HARDWARE

QTY DESCRIPTION MFG FIN

1 EA CARD READER MultiClass RP-40 HID N/A

IF req med assurance use: HW4 – ELECTRIFIED STRIKE

QTY DESCRIPTION MFG FIN

3 EA HINGE BB1191 4.5” X 4.5” HA 630

1 EA STORAGE 70-8204-LL-26D-SG SAR 626

1 EA SMALL FORMAT

INTERCHANGEABLE CORE

33N700006 MD 626

1 EA CLOSER 4111D (PUSH SIDE, DELAY) LCN 689

1 EA STOP STOP AS NEEDED BY CONDITION “ 626

2 EA ARMOR PLATE 8400 35”, UL LISTED NEEDED BY

CONDITION

IVES 630

1 EA ELEC STRIKE 1006-DBM2 WITH DEAD BOLT

MONITOR

HES 630

1 EA CARD READER MultiClass RP-40 HID N/A

IF has med assurance but needs new hardware use:HW5 – EXSISTING CARD READER TO BE INTERGRATED INTO NEW HARDWARE

QTY DESCRIPTION MFG FIN

3 EA HINGE BB1191 4.5” X 4.5” HA 630

1 EA STORAGE 70-8204-LL-26D-SG SAR 626

1 EA SMALL FORMAT

INTERCHANGEABLE CORE

33N700006 MD 626

1 EA CLOSER 4111D (PUSH SIDE, DELAY) LCN 689

1 EA STOP STOP AS NEEDED BY CONDITION “ 626

2 EA ARMOR PLATE 8400 35”, UL LISTED NEEDED BY

CONDITION

IVES 630

1 EA ELEC STRIKE 1006-DBM2 WITH DEAD BOLT

MONITOR

HES 630

IF req high assurance w/exsisting hardware use:HW6 – NEW CARD READER WITH KEYPAD TO BE INTERGRATED INTO EXSISTING HARDWARE

QTY DESCRIPTION MFG FIN

1 EA CARD READER MultiClass RPK-40 HID N/A

IF req high assurance w/o changing frame use:HW7 – ELECTRIFIED LOCKSET WITH KEYPAD HW7 cont. – ELECTRIFIED LOCKSET EQUIPMENT PER 4 TO 8 DOORS

QTY DESCRIPTION MFG FIN 1 EA POWER SUPPLY 3570 24V 6AMP SAR N/A

3 EA HINGE WTBB1191 4.5” X 4.5” HA 630 4-8 EA DOOR WIRE HARNESS TO

LOCKSET

CS443040

QC-C300, QC 12-38";

8&4P CNNCTR

MCK N/A

1 EA STORAGE NAC-82271 LNE IDP

PLUS SFIC CYLINDER

SAR 626 4-8 EA ACP WIRE HARNESS TO DOOR CS443042

QC-C1500, QC 12-15'2";

8&4P CNNCTR

MCK N/A

1 EA SMALL FORMAT

INTERCHANGEABLE CORE

33N700006 MD 626

1 EA CLOSER 4111D (PUSH SIDE, DELAY) LNC 689

2 EA ARMOR PLATE 8400 35”, UL LISTED NEEDED BY

CONDITION

IVES 630

1 EA STOP STOP AS NEEDED BY CONDITION,

WALL MOUNTED WITH BLOCKING

“ 626

1 EA CARD READER MultiClass RPK-40 HID N/A RPK-40 CAN BE USED WITHOUT KEYPAD (can be used in place of RP-40 but RP-40 CANNOT be used in place of RPK-40

1 EA ARMOR CORD MCK-TSB-C

DOOR CORD, GRAY/BLACKCAPS,18"

MCK N/A

IF req high assurance and can change frame use:HW8 – NEW ELECTRIFIED STRIKE WITH NEW CARD READER KEYPAD

QTY DESCRIPTION MFG FIN

3 EA HINGE BB1191 4.5” X 4.5” HA 630

1 EA STORAGE 70-8204-LL-26D-SG SAR 626

1 EA SMALL FORMAT

INTERCHANGEABLE CORE

33N700006 MD 626

1 EA CLOSER 4111D (PUSH SIDE, DELAY) LCN 689

1 EA STOP STOP AS NEEDED BY CONDITION “ 626

2 EA ARMOR PLATE 8400 35”, UL LISTED NEEDED BY

CONDITION

IVES 630

1 EA ELEC STRIKE 1006-DBM2 WITH DEAD BOLT

MONITOR

HES 630

1 EA CARD READER MultiClass RPK-40 HID N/A

IF high assurance req w/ exsisting hardware and preped frame use:HW9 – NEW CARD READER WITH KEYPAD AND NEW ELECTRIC STRIKE TO BE INTERGRATED INTO EXSISTING HARDWARE

QTY DESCRIPTION MFG FIN

1 EA CARD READER MultiClass RPK-40 HID N/A

1 EA ELEC STRIKE 1006-DBM2 WITH DEAD BOLT

MONITOR

HES 630

IF high assurance on non-egress double doors req use:HW10 – DOUBLE DOORS W/NEW ELECTRIFIED STRIKE WITH NEW CARD READER KEYPAD

QTY DESCRIPTION MFG FIN

6 EA HINGE BB1191 4.5” X 4.5” HA 630

1 EA STORAGE 70-8204-LL-26D-SG SAR 626 TO BE INSTALLED ON ACTIVE DOOR LEAF

1 EA SMALL FORMAT

INTERCHANGEABLE CORE

33N700006 MD 626

1 EA CLOSER 4111D (PUSH SIDE, DELAY) LCN 689 TO BE INSTALLED ON ACTIVE DOOR LEAF

BASIS OF DESIGN

MILWAUKEE VA

0730/4 COMPATIBLE

HARDWARE GROUPS

9/13/2021

2 EA STOP STOP AS NEEDED BY CONDITION “ 626

4 EA ARMOR PLATE 8400 23”, UL LISTED NEEDED BY

CONDITION

IVES 630

1 EA ELEC STRIKE 1006-DBM2 WITH DEAD BOLT

MONITOR

HES 630 TO BE INSTALLED ON INACTIVE DOOR LEAF

1 EA CARD READER MultiClass RPK-40 HID N/A

2 EA FLUSH BOLTS 261 4" Manual Flush Bolt IVES 26D TO BE INSTALLED ON INACTIVE DOOR LEAF

IF high assurance on egress double doors req use: HW11 – DOUBLE DOORS W/NEW EXIT DEVICE WITH NEW CARD READER

QTY DESCRIPTION MFG FIN

6 EA HINGE BB1191 4.5” X 4.5” HA 630

2 EA ELEC EXIT DEVICE Von Duprin EL-9927-F-LBR VON 626 Pull Trim (990NL), Rim Cylinder, and power supply (PS906 6amp) to be included with exit device

2 EA SMALL FORMAT

INTERCHANGEABLE CORE

33N700006 MD 626

0 EA CLOSER Exsisting Sentronic Fire closer LCN 689 Exsisting closer to be re-used and re-intergrated into the fire system.

2 EA STOP STOP AS NEEDED BY CONDITION “ 626

4 EA ARMOR PLATE 8400 23”, UL LISTED NEEDED BY

CONDITION

IVES 630

1 EA AUTO FLUSH BOLT FB41P WITH FIRE PIN IVES 626

1 EA CARD READER MultiClass RP-40 HID N/A

2 EA ARMOR CORD SCHLAGE 798 SERIES FIRE RATED

DOOR CORD UL 10 C

798C-18 (18" W/WIRES)

SCH N/A

IF high assurance in mental/behavioral health req use:HW12 – ANTI-LIGATURE NEW ELECTRIFIED STRIKE WITH NEW CARD READER KEYPAD

QTY DESCRIPTION MFG FIN

3 EA HINGE BB1191 4.5” X 4.5” HA 630

1 EA STORAGE CH 9159SEC Anti-Ligature Mortise ACC 626

1 EA SMALL FORMAT

INTERCHANGEABLE CORE

33N700006 MD 626

1 EA CLOSER 4111D (PUSH SIDE, DELAY) LCN 689

1 EA STOP STOP AS NEEDED BY CONDITION “ 626

2 EA ARMOR PLATE 8400 35”, UL LISTED NEEDED BY

CONDITION

IVES 630

1 EA ELEC STRIKE 1006-DBM2 WITH DEAD BOLT

MONITOR

HES 630

1 EA CARD READER MultiClass RPK-40 HID N/A

Milwaukee VAMC 01-01-16 695-21-700 EHRM Infrastructure Upgrades Final Bid Documents

Milwaukee, WI 53295 September 5, 2025

09 05 16 - 1

SECTION 09 05 16

SUBSURFACE PREPARATION FOR FLOOR FINISHES

A. This section specifies subsurface preparation requirements for areas to

B. receive the installation of applied and resinous flooring. This section includes removal of existing floor coverings, testing concrete…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .