RFP Attachment 29 - Drawings 695-21-700 Part 22.pdf
PDF 7 MB Posted
- Solicitation number
- 36C77626R0002
About this file
This is a technical drawing attachment for infrastructure upgrades at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin, part of RFP 36C77626R0002 Project #695-21-700. The document contains comprehensive site plans and building-level floor plans showing technology infrastructure installations across multiple buildings (Buildings 3-7, 20, 43, and 70) at the facility's 5000 W. National Avenue location. The drawings detail network cabling routes, telecommunications rooms, data closets, wireless access points, surveillance camera placements, and conduit pathways for both new installations and existing infrastructure to be preserved.
The technical specifications indicate new CAT6A cabling installations with detailed routing through building interiors and exterior pathways, including telecommunications infrastructure connecting to backbone paths designated as "Leg A" and "Leg B" for redundancy. Multiple telecommunications rooms (TRs) and demarcation points are identified throughout the campus, with specific room designations for each building's network termination. The drawings show demolition plans indicating removal of existing network cabling while preserving wireless access points and surveillance cameras. Handholes and manholes are specified at 500-foot intervals maximum, with new ductbank consisting of six 4-inch conduits. The document includes general notes regarding contractor responsibilities for J-hook routes, allowances for future outlet locations at 10 percent above identified drops, and references to civil drawings and additional specification sheets for comprehensive implementation details.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VBA
B
A
E
C
W A
S H
IN
G
T O
N D
R
IV
E
A F T O
N C
O U
R T
S th
S T
S th S
T
S n d
S T
S th S
T . S th
S T
S th S
T
S th S
T
WEST NATIONAL AVENUE
WASHINGTON DRIVE
W. WASHINGTON DR.
E
D
K
A
B
C
VOLUNTEER DRIVE
D D
C B
A111
115 116
119119
84 50
112 41
3 1
5 20
73 16
T114
99 T105
T106
T107
US
G E
N E
R A
L M
IT
C
H E
L L B
O U
L E
V A
R D
LINCOLN DRIVE
WAREHOUSE WAY
AMBULANCE WAY
C
IT
Y O
F W
E S
T A
L L
IS
C
IT
Y O
F M
IW
A
U K
E E
P U
B L
IC
A
L L
E Y
PUBLIC ALLEY
CITY OF MIWAUKEE
H
IN
E S
B L
V D
LAKE
WHEELER
FLOWER DRIVE
H
IN
E S B
LV
D
BA
R
RON
COURT
G E
N E
R A
L M
IT
C
H E
L L B
O U
L E
V A
R D
W O
O D
D R
IV
E
WORKSHOP ROAD
PAINT SHOP ROAD
HANK AARON TRAIL
FREDERICK MILLER WAY
FREDERICK MILLER WAY
C H R
YS
LER
R
O
AD
S
TA
D
IU
M
LA
N E
G E N E R A L M
ITC
H E
LL B
O U
LE
V A R D
M E
M O
R
IA
L D
R
IV
E
Z A B
LO
C K I D
R
IV
E
WALKER DRIVE
AMERICAN WAR MOTHERS AVENUE
J U
N E
A U
A V
E N
U E
W A
L C
O T
T A
V E
N U
E
KILBOURN CIRCLE
KILBOURN C
IR
CLE
WALCOTT AVENUE
HANK AARON TRAIL
CLC
BLDG.
ENG FF-112.0'
ARCH FF-100.0'
CLC
BLDG.
ENG FF-109.0'
ARCH FF-100.0'
PW-HH-1
PW-MH-1
BACKBONE "B"
LEG DIRECTION
BACKBONE "A"
LEG DIRECTION
BACKBONE "A"
LEG DIRECTION
BACKBONE "B"
LEG DIRECTION
PW-MH-1PW-HH-1
PW-MH-1
PW-MH-1
PW-MH-1
PW-MH-1
PW-MH-1
PW-MH-1
PW-MH-1
PW-HH-1
PW-HH-1
PW-HH-1
PW-HH-1
PW-HH-1
PW-HH-1
MAN HOLE
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03 0
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:3
P M
TECHNOLOGY SITE PLAN
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
T1003
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1" = 200'-0"
TECHNOLOGY SITE PLAN
GENERAL NOTES:
1. REFER TO CIVIL DRAWINGS FOR ADDITIONAL PATHWAY
INFORMATION.
2. REFER TO 1/TN508 FOR TECHNOLOGY SITE RISER
DIAGRAM.
3. HANDHOLES SHALL BE 36"L X 24"W X 18" D UNLESS NOTED
OTHERWISE.
4. REFER TO INDIVIDUAL BUILDING DRAWINGS FOR
ADDITIONAL INFORMATION REGARDING ENTRY
LOCATIONS, CONDUIT SIZING AND CONDUIT QUANTITY.
5. REFER TO CIVIL DRAWINGS FOR EXISTING MANHOLES
WHICH ARE TO BE REMEDIATED FOR DRAINAGE.
6. REFER TO 3/TN400 FOR TELECOMMUNICATIONS MANHOLE
DETAIL.
7. UNLESS NOTED OTHERWISE, NEW DUCTBANK SHALL BE
SIX (6) 4" CONDUITS. REFER TO 4/TN400 FOR DETAIL.
8. MANHOLES AND HAND HOLES SHALL BE PLACED NO
GREATER THAN 500' APART, BASED ON CONDUIT PATH.
KEYNOTES:
1. FOUR (4) 4" CONDUITS IN DUCT BANK FOR SECONDARY
PROVIDER PATH. DEMARCATION ROOM IS LOCATED IN
BUILDING 111, FIRST FLOOR, ROOM 1470.
2. PROVIDE TWO (2) 4" CONDUITS FROM HANDHOLE INTO
THE MAUSOLEUM. CONDUITS SHALL CONTINUE IN LEG "A"
DIRECTION TO BUILDING 111.
3. CENTURY LINK SHALL PROVIDE THEIR CABLES IN
CONTRACTOR PROVIDED DUCTBANK. DEMARCATION
ROOM IS LOCATED IN BUILDING 111, FIRST FLOOR, ROOM
1470.
4. REFER TO 3/TN400 FOR TELECOMMUNICATIONS MANHOLE
DETAIL.
5. EXISTING COPPER VOICE BACKBONE TO REMAIN.
PROTECT IN PLACE.
6. REFER TO INDIVIDUAL BUILDING FLOOR PLANS FOR
BACKBONE ENTRANCE LOCATIONS.
7. BACKBONE PATHS SHALL CONSIST OF AN "A" LEG AND A
"B" LEG. THE "A" LEG SHALL RUN COUNTERCLOCKWISE IN
THE MAIN LOOP, THE "B" LEG SHALL RUN CLOCKWISE.
8. NEW DUCT BANK CONSISTING OF SIX (6) 4" CONDUITS.
9. FOUR (4) 4" CONDUITS TO BE INSTALLED IN EXISTING
TUNNEL.
10. TWO (2) 4" CONDUITS FOR LEG B ENTRANCE INTO
BUILDING 123.
11. TWO (2) 4" CONDUITS AS LEG "B" PATH INTO BUILDINGS
146, 147, 148.
12. EXISTING PATHWAY TO BUILDINGS 146, 147, 148 TO BE
REUSED, LEG "A"
13. TWO (2) 4" CONDUITS TO MAIN DUCT BANK AS LEG "B"
INTO BUILDING 6.
14. TWO (2) 4" CONDUITS TO MAIN DUCT BANK AS LEG "A"
INTO BUILDING 6.
15. TWO (2) 4" CONDUITS FROM EXISTING TUNNEL TO
BUILDING 3 AND BUILDING 4.
16. EXISTING PATHWAYS BETWEEN BUILDINGS 70 AND 123 TO
BE REUSED.
17. REFER TO 123-T201D FOR CONTINUATION. TWO (2) 4"
CONDUITS
18. NEW DUCT BANK SHALL CONNECT TO EXISTING STEAM
TUNNEL.
19. FROM HERE TO KEYNOTE #18 THIS SHEET IS AN EXISTING
PATHWAY IN A TUNNEL. TUNNEL SHALL BE RE-USED AS A
PATHWAY.
20. SECONDARY BACKBONE PATH. TWO (2) 4" CONDUITS.
21. SECONDARY BACKBONE PATH. TWO (2) 4" CONDUITS 36"
BELOW GRADE FROM WALL OF EXISTING STEAM TUNNEL
VENT/MANHOLE INTO BUILDING 144. REFER TO SHEET 144-
T200B FOR ADDITIONAL INFORMATION.
22. EXISTING HANDHOLES TO REMAIN.
23. EXISTING PATHWAY TO BE REUSED.
Revisions: Date:
STORAGE
ENTRY
TOILET
TOILET
READING RM
LIBRARIAN'S WORK AREA
VESTIBULE
HAC
2D 2V
1D-WAP
1D-WAP
1D-WAP
1D-CAM
1D-WAP
1D-WAP
1D-CAM
1D-CAM
1D
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:3
P M
BUILDING 03 FIRST FLOOR DEMO PLAN -
TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
03-TD101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/4" = 1'-0"
BUILDING 03 FIRST FLOOR DEMOLITION PLAN - TECHNOLOGY
KEYNOTES:
1. WALL MOUNTED RACK TO BE DEMOLISHED
AFTER NEW RACK IS INSTALLED.
SHEET NOTES:
1. REMOVE ALL NETWORK CABLING TO POINTS
OF TERMINATION IN ASSOCIATED DATA
CLOSET. REFER TO FLOOR PLANS AND SHEET
T1001 FOR TR ROOM LOCATIONS.
2. REFER TO ARCHITECTURAL PHASING PLANS
FOR WHEN EXISTING CABLING IS ALLOWED TO
BE DEMOLISHED.
3. FOR ALL EXISTING WIRELESS ACCESS POINTS
AND SURVEILLANCE CAMERAS, DEVICES
SHALL REMAIN. SCOPE OF WORK INCLUDES
CABLE REPLACEMENT ONLY. COORDINATE
WITH COR FOR ANY DOWNTIME OF DEVICES.
4. EXISTING LOCATIONS OF WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT
NECESSARILY BE IN THE EXACT LOCATION AS
IDENTIFIED.
B O
O K
S H
E
LF
BOOK SHELF
BOOK SHELF
B O
O K
S H
E
LF
1D-WAP
1D-WAP 1D-WAP
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:3
P M
BUILDING 03 SECOND FLOOR DEMO PLAN -
TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
03-TD102
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/4" = 1'-0"
BUILDING 03 SECOND FLOOR DEMOLITION PLAN - TECHNOLOGY
SHEET NOTES:
1. REMOVE ALL NETWORK CABLING TO POINTS
OF TERMINATION IN ASSOCIATED DATA
CLOSET. REFER TO FLOOR PLANS AND SHEET
T1001 FOR TR ROOM LOCATIONS.
2. REFER TO ARCHITECTURAL PHASING PLANS
FOR WHEN EXISTING CABLING IS ALLOWED TO
BE DEMOLISHED.
3. FOR ALL EXISTING WIRELESS ACCESS POINTS
AND SURVEILLANCE CAMERAS, DEVICES
SHALL REMAIN. SCOPE OF WORK INCLUDES
CABLE REPLACEMENT ONLY. COORDINATE
WITH COR FOR ANY DOWNTIME OF DEVICES.
4. EXISTING LOCATIONS OF WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT
NECESSARILY BE IN THE EXACT LOCATION AS
STORAGE
ENTRY
TOILET
TOILET
READING RM
LIBRARIAN'S WORK AREA
VESTIBULE
HAC
2D 2V
1D-WAP
1D-WAP
1D-WAP
1D-CAM
1D-WAP
1D-WAP
1D-CAM
1D-CAM
1D
TN300
TN300
TELECOMMUNICATIONS
RM.
TE-3-1454
TO EXISTING HAND HOLE, REFER
TO T1003 FOR CONTINUATION
TELECOM ROOM
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:3
P M
BUILDING 03 FIRST FLOOR PLAN - TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
03-TN101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/4" = 1'-0"
BUILDING 03 FIRST FLOOR PLAN - TECHNOLOGY
SHEET NOTES:
1. REFER TO 1/TN400 FOR TECHNOLOGY ROUGH
IN DETAIL.
2. ALL NETWORK CABLES ON THIS SHEET SHALL
TERMINATE IN TE-3-1454.
3. REFER TO CIVIL DRAWINGS AND T1003 FOR
ADDITIONAL PATHWAY INFORMATION.
4. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
5. REFER TO TN500-TN509 FOR RISER DIAGRAMS.
6. REFER TO SHEET TN402 FOR PENETRATION
DETAILS.
7. THESE DRAWINGS MAKE THE BEST ATTEMPT
TO IDENTIFY EXISTING DATA DROPS/WORK
AREA OUTLETS. AS LONG AS THE TOTAL
NEWLY INSTALLED DATA DROP COUNT DOES
NOT VARY +/- 10% IDENTIFIED ON THESE
DRAWINGS, THE CONTRACTOR'S SCOPE
SHALL BE UNCHANGED.
8. NEW WORK AREA OUTLETS SHALL BE
LOCATED IN EXISTING BOXES. WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT BE
IN THE EXACT LOCATION AS IDENTIFIED.
9. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10% ADDITIONAL 2-PORTS CAT6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
KEYNOTES:
1. EXISTING BACKBONE ENTRY POINT, PROTECT
IN PLACE. DEMOLISH EXISTING FIBER OPTIC
CABLE TO POINTS OF TERMINATION AFTER
REDUNDANT PATH IS INSTALLED AND
OPERATIONAL. REFER TO ARCHITECTURAL
PHASING PLAN FOR ADDITIONAL
INFORMATION. CONDUIT ENTERS ON LOWER
LEVEL.
NTS
KEY PLAN - BLDG 3
2873.7 sq.ft.
1D-WAP
1D-WAP 1D-WAP
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:3
P M
BUILDING 03 SECOND FLOOR PLAN -
TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
03-TN102
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/4" = 1'-0"
BUILDING 03 SECOND FLOOR PLAN - TECHNOLOGY
M E
R
STAIR
ELECTRICAL
CORRIDOR
RESTROOMRESTROOM
ELEVATOR
MACH RM ELEVATOR
BOWLING LANES
RECEPTION
STORAGE
MER
STAIR
01050104
01030100
D
V
1D-WAP
1D-WAP
1D-WAP
1D-WAP
2D 2V
TO EXISTING HAND HOLE,
REFER TO T1003 FOR
CONTINUATION
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:3
P M
BUILDING 04 BASEMENT DEMO PLAN -
TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
04-TD100
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/4" = 1'-0"
BUILDING 04 BASEMENT FLOOR DEMOLITION PLAN - TECHNOLOGY
SHEET NOTES:
1. REMOVE ALL NETWORK CABLING TO POINTS
OF TERMINATION IN ASSOCIATED DATA
CLOSET. REFER TO FLOOR PLANS AND SHEET
T1001 FOR TR ROOM LOCATIONS.
2. REFER TO ARCHITECTURAL PHASING PLANS
FOR WHEN EXISTING CABLING IS ALLOWED TO
BE DEMOLISHED.
3. FOR ALL EXISTING WIRELESS ACCESS POINTS
AND SURVEILLANCE CAMERAS, DEVICES
SHALL REMAIN. SCOPE OF WORK INCLUDES
CABLE REPLACEMENT ONLY. COORDINATE
WITH COR FOR ANY DOWNTIME OF DEVICES.
4. EXISTING LOCATIONS OF WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT
NECESSARILY BE IN THE EXACT LOCATION AS
HAC
RESTROOM RESTROOM
OFFICE
STORAGE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
IT
OFFICE
OFFICE
OFFICEOFFICE
LOBBY CORRIDOR
STAIR
ELEVATOR
STAIR
PATIO
1101HC
1118 1117
1108 1109 1110 1111 1112 1113 1114 1115
11041105
D
V
D
V
D
V 2 D
V
D
V
D
V
D
V
2D2V
D
V
D
V
1D-WAP
1D-WAP
1D-WAP
1D-WAP
2D 2V
2D2V
1D-CAM1D-WAP
1D-WAP
2D2V
2D 2V
D
V
D
V
D
V
2D 2V
2D
2D 2V
EXISTING TR
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:3
P M
BUILDING 04 FIRST FLOOR DEMO PLAN -
TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
04-TD101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/4" = 1'-0"
BUILDING 04 FIRST FLOOR DEMOLITION PLAN - TECHNOLOGY
SHEET NOTES:
1. REMOVE ALL NETWORK CABLING TO POINTS
OF TERMINATION IN ASSOCIATED DATA
CLOSET. REFER TO FLOOR PLANS AND SHEET
T1001 FOR TR ROOM LOCATIONS.
2. REFER TO ARCHITECTURAL PHASING PLANS
FOR WHEN EXISTING CABLING IS ALLOWED TO
BE DEMOLISHED.
3. FOR ALL EXISTING WIRELESS ACCESS POINTS
AND SURVEILLANCE CAMERAS, DEVICES
SHALL REMAIN. SCOPE OF WORK INCLUDES
CABLE REPLACEMENT ONLY. COORDINATE
WITH COR FOR ANY DOWNTIME OF DEVICES.
4. EXISTING LOCATIONS OF WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT
NECESSARILY BE IN THE EXACT LOCATION AS
RESTROOM
CUBICLES
RECEPTION
LOBBY
OFFICE
CORRIDOR
HAC
KITCHEN
IT
CONFERENCEOFFICEOFFICEOFFICEOFFICEOFFICE
STORAGE
STAIR
ELEVATOR
STAIR
2101HC
211121102109210821072106
D
V
D
V
D
V
2D 2V
2D2V
1D-WAP
1D-WAP
1D-WAP
1D-WAP
2D 2V
2D 2V
2D2V2D2V
2D 2V
D
V
2D 2V
2D 2V
D
V
D
V
D
V
2D2V
2D2V
2D 2V
2D2V
D
V
D
V
2D2V
D
V
D
V
1 3
2 2
EXISTING TR
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:3
P M
BUILDING 04 SECOND FLOOR DEMO PLAN -
TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
04-TD102
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/4" = 1'-0"
BUILDING 04 SECOND FLOOR DEMOLITION PLAN - TECHNOLOGY
SHEET NOTES:
1. REMOVE ALL NETWORK CABLING TO POINTS
OF TERMINATION IN ASSOCIATED DATA
CLOSET. REFER TO FLOOR PLANS AND SHEET
T1001 FOR TR ROOM LOCATIONS.
2. REFER TO ARCHITECTURAL PHASING PLANS
FOR WHEN EXISTING CABLING IS ALLOWED TO
BE DEMOLISHED.
3. FOR ALL EXISTING WIRELESS ACCESS POINTS
AND SURVEILLANCE CAMERAS, DEVICES
SHALL REMAIN. SCOPE OF WORK INCLUDES
CABLE REPLACEMENT ONLY. COORDINATE
WITH COR FOR ANY DOWNTIME OF DEVICES.
4. EXISTING LOCATIONS OF WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT
NECESSARILY BE IN THE EXACT LOCATION AS
M E
R
STAIR
ELECTRICAL
CORRIDOR
RESTROOMRESTROOM
ELEVATOR
MACH RM ELEVATOR
BOWLING LANES
RECEPTION
STORAGE
MER
STAIR
01050104
01030100
D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
2D
ONE (1) 4"
EXPOSED
CONDUIT,
SECURED
TIGHT TO
STRUCTURE.
PW-HH-1
JBJB
TO EXISTING HAND HOLE,
REFER TO T1003 FOR
CONTINUATION.
REFER TO T1003 FOR
CONTINUATION
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:3
P M
BUILDING 04 BASEMENT PLAN - TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
04-TN100
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/4" = 1'-0"
BUILDING 04 BASEMENT PLAN - TECHNOLOGY
SHEET NOTES:
1. ALL NETWORK CABLES ON THIS SHEET SHALL
TERMINATE IN TR-4-2110.
2. REFER TO CIVIL DRAWINGS AND T1003 FOR
ADDITIONAL PATHWAY INFORMATION.
3. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
4. REFER TO TN500-TN509 FOR RISER DIAGRAMS.
5. REFER TO SHEET TN402 FOR PENETRATION
DETAILS.
6. THESE DRAWINGS MAKE THE BEST ATTEMPT
TO IDENTIFY EXISTING DATA DROPS/WORK
AREA OUTLETS. AS LONG AS THE TOTAL
NEWLY INSTALLED DATA DROP COUNT DOES
NOT VARY +/- 10% IDENTIFIED ON THESE
DRAWINGS, THE CONTRACTOR'S SCOPE
SHALL BE UNCHANGED.
7. NEW WORK AREA OUTLETS SHALL BE
LOCATED IN EXISTING BOXES. WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT BE
IN THE EXACT LOCATION AS IDENTIFIED.
8. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10% ADDITIONAL 2-PORTS CAT6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
KEYNOTES:
1. TWO (2) 4" CONDUITS TO BACKBONE PATH.
2. EXISTING BACKBONE ENTRY POINT, PROTECT
IN PLACE. DEMOLISH EXISTING FIBER OPTIC
CABLE TO POINTS OF TERMINATION AFTER
REDUNDANT PATH IS INSTALLED AND
OPERATIONAL. REFER TO ARCHITECTURAL
PHASING PLAN FOR ADDITIONAL
INFORMATION. CONDUIT ENTERS ON LOWER
LEVEL.
HAC
RESTROOM RESTROOM
OFFICE
STORAGE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
IT
OFFICE
OFFICE
OFFICEOFFICE
LOBBY CORRIDOR
STAIR
ELEVATOR
STAIR
PATIO
1101HC
1118 1117
1108 1109 1110 1111 1112 1113 1114 1115
11041105
D
D
D
D
D
D
2D
D
D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-CAM1D-WAP
1D-WAP
1D-CAM
D
D
2D
D
ONE (1) 4" CONDUIT, ABOVE CEILING
ONE (1) 4" CONDUIT TO BELOW
ONE (1) 4" CONDUIT, ABOVE
CEILING, UP TO SECOND
FLOOR TR-4-2-1
ONE (1) 4" CONDUIT
FROM BELOW TO
TR ABOVE
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:4
P M
BUILDING 04 FIRST FLOOR PLAN - TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
04-TN101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/4" = 1'-0"
BUILDING 04 FIRST FLOOR PLAN - TECHNOLOGY
SHEET NOTES:
1. REFER TO 1/TN400 FOR TECHNOLOGY ROUGH
IN DETAIL.
2. ALL NETWORK CABLES ON THIS SHEET SHALL
TERMINATE IN TR-4-2110.
3. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
4. REFER TO TN500-TN509 FOR RISER DIAGRAMS.
5. REFER TO SHEET TN402 FOR PENETRATION
DETAILS.
6. THESE DRAWINGS MAKE THE BEST ATTEMPT
TO IDENTIFY EXISTING DATA DROPS/WORK
AREA OUTLETS. AS LONG AS THE TOTAL
NEWLY INSTALLED DATA DROP COUNT DOES
NOT VARY +/- 10% IDENTIFIED ON THESE
DRAWINGS, THE CONTRACTOR'S SCOPE
SHALL BE UNCHANGED.
7. NEW WORK AREA OUTLETS SHALL BE
LOCATED IN EXISTING BOXES. WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT BE
IN THE EXACT LOCATION AS IDENTIFIED.
8. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10% ADDITIONAL 2-PORTS CAT6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
KEYNOTES:
1. PROVIDE 25 PAIR VOICE COPPER CABLE FROM
EXISTING WALL FIELD TO NEW TR, ROOM 2110.
RESTROOM
CUBICLES
RECEPTION
LOBBY
OFFICE
CORRIDOR
HAC
KITCHEN
IT
CONFERENCEOFFICEOFFICEOFFICEOFFICEOFFICE
STORAGE
STAIR
ELEVATOR
STAIR
2101HC
211121102109210821072106
D
D
D
2D
2D
1D-WAP
1D-WAP
1D-WAP
1D-WAP
2D
6D
D
2D
2D
D
D
4D
CCTV
TELECOMMUNICATIONS
RM
CONFERENCE RM
TN300
TN300
TR-04-2110
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:4
P M
BUILDING 04 SECOND FLOOR PLAN -
TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
04-TN102
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/4" = 1'-0"
BUILDING 04 SECOND FLOOR PLAN - TECHNOLOGY
SHEET NOTES:
1. REFER TO 1/TN400 FOR TECHNOLOGY ROUGH
IN DETAIL.
2. ALL NETWORK CABLES ON THIS SHEET SHALL
TERMINATE IN TR-4-2110.
3. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
4. REFER TO TN500-TN509 FOR RISER DIAGRAMS.
5. REFER TO SHEET TN402 FOR PENETRATION
DETAILS.
6. THESE DRAWINGS MAKE THE BEST ATTEMPT
TO IDENTIFY EXISTING DATA DROPS/WORK
AREA OUTLETS. AS LONG AS THE TOTAL
NEWLY INSTALLED DATA DROP COUNT DOES
NOT VARY +/- 10% IDENTIFIED ON THESE
DRAWINGS, THE CONTRACTOR'S SCOPE
SHALL BE UNCHANGED.
7. NEW WORK AREA OUTLETS SHALL BE
LOCATED IN EXISTING BOXES. WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT BE
IN THE EXACT LOCATION AS IDENTIFIED.
8. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10% ADDITIONAL 2-PORTS CAT6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
CLOSET
CLOSET
CLOSET
UP
RAMP DN
UP
DN
DN
DN
DN
DN
UP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
2D 2V 2D 2V
2D2V
2D 2V
D
V
2D2V 2D2V
2D 2V
1D-WAP
1D-CAM
D
V
D
V
1D-CAM
1D-WAP
D
V
D
V
2D2V
D
V
3D1V3D1V
D
V
1D-CAM
D
V
D
V
1D-WAP
2D 2V
1D
D
V
D
V
1D
1D1D1D1D
1D1D
D
D
V
D
V
D
D
D
V
D
V
2D2V
1D
1D
1D 2D 2D 1D
2D2V
D
D
2D 2V 2 D
V
D
D
V
D
V
D
V
3D1V 3D1V
D
V
2D 2V2D 2V
D
V
2D2V
2D2V
D
V
D
V
3D1V
EXISTING
TELECOMMUNICATIONS
RM.
POWER POLE
TN301
2 2
1 1
3 3
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:4
P M
BUILDING 05 FIRST FLOOR DEMO -
TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
05-TD101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/8" = 1'-0"
BUILDING 05 FIRST FLOOR DEMOLITION - TECHNOLOGY
SHEET NOTES:
1. REMOVE ALL NETWORK CABLING TO POINTS
OF TERMINATION IN ASSOCIATED DATA
CLOSET. REFER TO FLOOR PLANS AND SHEET
T1001 FOR TR ROOM LOCATIONS.
2. REFER TO ARCHITECTURAL PHASING PLANS
FOR WHEN EXISTING CABLING IS ALLOWED TO
BE DEMOLISHED.
3. FOR ALL EXISTING WIRELESS ACCESS POINTS
AND SURVEILLANCE CAMERAS, DEVICES
SHALL REMAIN. SCOPE OF WORK INCLUDES
CABLE REPLACEMENT ONLY. COORDINATE
WITH COR FOR ANY DOWNTIME OF DEVICES.
4. EXISTING LOCATIONS OF WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT
NECESSARILY BE IN THE EXACT LOCATION AS
IDENTIFIED.
KEYNOTES:
1. EXISTING DATA CLOSET, PROTECT IN PLACE.
TR-05-117
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
2D1V 2D1V 2D1V2D1V
D
V
2D1V
2D1V
2D 1V 2D 1V
2D 1V 2D 1V
D
V
2D1V
2D 1V
D
V 2 D
V
D
V
2D1V 2D1V 2D1V
2D 1V 2D1V
2D1V
2D 1V
2D 1V 2D 1V
D
V
2D1V
2D2V
2D 1V2D 1V
TELECOMMUNICATIONS
RM.
144B
EXISTING
TELECOMMUNICATIONS
RM
EXISTING DATA
CLOSET
2 2 2 3 2
1 1
1 2
2 2 1
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:4
P M
BUILDING 05 SECOND FLOOR DEMO PLAN -
TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
05-TD102
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/8" = 1'-0"
BUILDING 05 SECOND FLOOR DEMOLITION PLAN - TECHNOLOGY
SHEET NOTES:
1. REMOVE ALL NETWORK CABLING TO POINTS
OF TERMINATION IN ASSOCIATED DATA
CLOSET. REFER TO FLOOR PLANS AND SHEET
T1001 FOR TR ROOM LOCATIONS.
2. REFER TO ARCHITECTURAL PHASING PLANS
FOR WHEN EXISTING CABLING IS ALLOWED TO
BE DEMOLISHED.
3. FOR ALL EXISTING WIRELESS ACCESS POINTS
AND SURVEILLANCE CAMERAS, DEVICES
SHALL REMAIN. SCOPE OF WORK INCLUDES
CABLE REPLACEMENT ONLY. COORDINATE
WITH COR FOR ANY DOWNTIME OF DEVICES.
4. EXISTING LOCATIONS OF WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT
NECESSARILY BE IN THE EXACT LOCATION AS
DN
DN
302AEC
3-03
3-01
3-04
3-05
ELECTRICAL
ACCNT
MGR OFFICE
BUDGET OFFICE
STAIR
DEPUTY
FINANCIAL MGR
OFFICE
MGMT
ANALYST
OFFICE
OFFICE
CONFERENCE
OFFICE
ELEVATOR
KITCHEN
OPEN
OFFICE
STAIR
TOILET
STAIR
ACCNT
ACCNT
OFFICE
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
2D 2V
2D2V
D
V
D
V
D
V
D
V
D
V
2D2V
1D-WAP
2D2V2D2V
2D 2V 2D 2V
2D 2V
2D2V
2D2V
D
V 2 D
V
D
V
D
V 2
D V 2 D
V 2 D
V
D
V
2D2V
D
V
2D 2V
2D1V
2D 2V
1D-WAP
2D2V
2D2V
D
V
3D1V
3D 1V
2D2V
D
V
2D2V
D
V
2D 2V
TR-5-313
EXISTING
DATA
CLOSET
21222
2 2
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:4
P M
BUILDING 05 THIRD FLOOR DEMO PLAN -
TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
05-TD103
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/8" = 1'-0"
BUILDING 05 THIRD FLOOR DEMOLITION PLAN - TECHNOLOGY
SHEET NOTES:
1. REMOVE ALL NETWORK CABLING TO POINTS
OF TERMINATION IN ASSOCIATED DATA
CLOSET. REFER TO FLOOR PLANS AND SHEET
T1001 FOR TR ROOM LOCATIONS.
2. REFER TO ARCHITECTURAL PHASING PLANS
FOR WHEN EXISTING CABLING IS ALLOWED TO
BE DEMOLISHED.
3. FOR ALL EXISTING WIRELESS ACCESS POINTS
AND SURVEILLANCE CAMERAS, DEVICES
SHALL REMAIN. SCOPE OF WORK INCLUDES
CABLE REPLACEMENT ONLY. COORDINATE
WITH COR FOR ANY DOWNTIME OF DEVICES.
4. EXISTING LOCATIONS OF WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT
NECESSARILY BE IN THE EXACT LOCATION AS
CLOSET
CLOSET
UP
RAMP DN
UP
DN
DN
DN
DN
DN
UP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
2D 2D
2D
2D
D
2D 2D
2D
1D-WAP
1D-CAM
D
D
1D-CAM
1D-WAP
D
D
2D
D
2D2D
D
1D-CAM
D
D
1D-WAP
D
D
2D 2D
D
TR-05-117
EXISTING
TELECOMMUNICATIONS
RM.
TN301
TN301
REFER TO T1003 FOR
CONTINUATION
REFER TO T1003 FOR
CONTINUATION
TELECOM ROOM LOCATION
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:4
P M
BUILDING 05 FIRST FLOOR PLAN - TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
05-TN101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/8" = 1'-0"
BUILDING 05 FIRST FLOOR PLAN - TECHNOLOGY
SHEET NOTES:
1. ALL NETWORK CABLES ON THIS SHEET SHALL
TERMINATE IN TR-05-117.
2. REFER TO CIVIL DRAWINGS AND T1003 FOR
ADDITIONAL PATHWAY INFORMATION.
3. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
4. REFER TO TN500-TN509 FOR RISER DIAGRAMS.
5. REFER TO SHEET TN402 FOR PENETRATION
DETAILS.
6. THESE DRAWINGS MAKE THE BEST ATTEMPT
TO IDENTIFY EXISTING DATA DROPS/WORK
AREA OUTLETS. AS LONG AS THE TOTAL
NEWLY INSTALLED DATA DROP COUNT DOES
NOT VARY +/- 10% IDENTIFIED ON THESE
DRAWINGS, THE CONTRACTOR'S SCOPE
SHALL BE UNCHANGED.
7. NEW WORK AREA OUTLETS SHALL BE
LOCATED IN EXISTING BOXES. WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT BE
IN THE EXACT LOCATION AS IDENTIFIED.
8. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10% ADDITIONAL 2-PORTS CAT6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
KEYNOTES:
1. ACCESS CONTROL PANEL PANEL LOCATION.
GC TO COORDINATE EXACT LOCATION AND
HEIGHT WITH COR TO RE-CONNECT TO
SWITCH/RACK TE IN SAME ROOM WITH CAT6A
CABLE AS NECESSARY.
2. EXISTING BACKBONE ENTRY POINT, PROTECT
IN PLACE. DEMOLISH EXISTING FIBER OPTIC
CABLE TO POINTS OF TERMINATION AFTER
REDUNDANT PATH IS INSTALLED AND
OPERATIONAL. REFER TO ARCHITECTURAL
PHASING PLAN FOR ADDITIONAL
INFORMATION. CONDUIT ENTERS ON LOWER
LEVEL.
NTS
KEY PLAN - BLDG 5 1ST
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
2D 2D 2D2D
D
2D
2D
2D 2D
2D 2D
D
2D
2D
D 2 D
D
TELECOMMUNICATIONS
RM.
144B
EXISTING
TELECOMMUNICATIONS
RM
TN301
TN301
TR-05-204
EXISTING DATA CLOSET
TELECOM ROOM LOCATION
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:4
P M
BUILDING 05 SECOND FLOOR PLAN -
TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
05-TN102
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/8" = 1'-0"
BUILDING 05 SECOND FLOOR PLAN - TECHNOLOGY
SHEET NOTES:
1. REFER TO 1/TN400 FOR TECHNOLOGY ROUGH
IN DETAIL.
2. ALL NETWORK CABLES ON THIS SHEET SHALL
TERMINATE IN TR-5-204.
3. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
4. REFER TO TN500-TN509 FOR RISER DIAGRAMS.
5. REFER TO SHEET TN402 FOR PENETRATION
DETAILS.
6. THESE DRAWINGS MAKE THE BEST ATTEMPT
TO IDENTIFY EXISTING DATA DROPS/WORK
AREA OUTLETS. AS LONG AS THE TOTAL
NEWLY INSTALLED DATA DROP COUNT DOES
NOT VARY +/- 10% IDENTIFIED ON THESE
DRAWINGS, THE CONTRACTOR'S SCOPE
SHALL BE UNCHANGED.
7. NEW WORK AREA OUTLETS SHALL BE
LOCATED IN EXISTING BOXES. WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT BE
IN THE EXACT LOCATION AS IDENTIFIED.
8. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10% ADDITIONAL 2-PORTS CAT6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
NTS
KEY PLAN - BLDG 5 2ND
DN
302AEC
3-03
3-01
3-04
3-05
ELECTRICAL
ACCNT
MGR OFFICE
BUDGET OFFICE
STAIR
DEPUTY
FINANCIAL MGR
OFFICE
MGMT
ANALYST
OFFICE
OFFICE
CONFERENCE
OFFICE
ELEVATOR
KITCHEN
OPEN
OFFICE
STAIR
TOILET
STAIR
ACCNT
ACCNT
OFFICE
1D-WAP
1D-WAP
1D-WAP 1D-WAP
1D-WAP
1D-WAP
1D-WAP
2D
2D
D
D
D
D 2
D
2D
1D-WAP
2D
2D
2D
2D
D 2 D
D
D 2
D
D 2
D
D
2D
D2D
2D
2D
1D-WAP
2D
2D
D
2D
2D
EXISTING TELECOMMUNICATION RM.
EXISTING DATA CLOSET
TELECOM ROOM LOCATION
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:4
P M
BUILDING 05 THIRD FLOOR PLAN -
TECHNOLOGY
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
05-TN103
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/8" = 1'-0"
BUILDING 05 THIRD FLOOR PLAN - TECHNOLOGY
SHEET NOTES:
1. ALL NETWORK CABLES ON THIS SHEET SHALL
TERMINATE IN TR-05-204 .
2. CONTRACTOR TO PROVIDE NEW J-HOOK
ROUTES FOR ALL NEW CABLING. J-HOOK SIZE
AND QUANTITY TO BE PER MANUFACTURER
RECOMMENDATIONS.
3. REFER TO TN500-TN509 FOR RISER DIAGRAMS.
4. REFER TO SHEET TN402 FOR PENETRATION
DETAILS.
5. THESE DRAWINGS MAKE THE BEST ATTEMPT
TO IDENTIFY EXISTING DATA DROPS/WORK
AREA OUTLETS. AS LONG AS THE TOTAL
NEWLY INSTALLED DATA DROP COUNT DOES
NOT VARY +/- 10% IDENTIFIED ON THESE
DRAWINGS, THE CONTRACTOR'S SCOPE
SHALL BE UNCHANGED.
6. NEW WORK AREA OUTLETS SHALL BE
LOCATED IN EXISTING BOXES. WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT BE
IN THE EXACT LOCATION AS IDENTIFIED.
7. CONTRACTOR TO INCLUDE AN ALLOWANCE
FOR 10% ADDITIONAL 2-PORTS CAT6A
INFORMATION OUTLETS IN THEIR PROPOSAL
FOR THIS SHEET. FUTURE INFORMATION
OUTLET LOCATIONS WILL BE DETERMINED BY
THE VA AT A LATER DATE.
KEYNOTES:
1. USE EXISTING CLOSET AS CABLE PASS-THRU
FOR HORIZONTAL CABLES ON 3RD FLOOR TO
TERMINATE IN CLOSET ON LEVEL 2.
TR-5-313
NTS
KEY PLAN - BLDG 5
R A
M P
U P
R A
M P
U P
UP
UP
UP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
2D2V
D
V
D
V
D
V
D
V
D
V
D
V
D
V
2D 2V
2D 2V
1D-WAP
UP
UP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
2D 1V1
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:4
P M
BUILDING 06 BASEMENT DEMO PLAN -
TECHNOLOGY - AREA A
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
06-TD100A
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/8" = 1'-0"
BUILDING 06 BASEMENT FLOOR DEMOLITION PLAN - TECHNOLOGY - AREA A NORTH
1 1/8" = 1'-0"
BUILDING 06 BASEMENT FLOOR DEMOLITION PLAN - TECHNOLOGY - AREA A SOUTH
SHEET NOTES:
1. REMOVE ALL NETWORK CABLING TO POINTS
OF TERMINATION IN ASSOCIATED DATA
CLOSET. REFER TO FLOOR PLANS AND SHEET
T1001 FOR TR ROOM LOCATIONS.
2. REFER TO ARCHITECTURAL PHASING PLANS
FOR WHEN EXISTING CABLING IS ALLOWED TO
BE DEMOLISHED.
3. FOR ALL EXISTING WIRELESS ACCESS POINTS
AND SURVEILLANCE CAMERAS, DEVICES
SHALL REMAIN. SCOPE OF WORK INCLUDES
CABLE REPLACEMENT ONLY. COORDINATE
WITH COR FOR ANY DOWNTIME OF DEVICES.
4. EXISTING LOCATIONS OF WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT
NECESSARILY BE IN THE EXACT LOCATION AS
RAMP
A
M P
U P
UP
UP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
AREA A - NORTH
AREA A - SOUTH
AREA B
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:4
P M
BUILDING 06 BASEMENT DEMO PLAN -
TECHNOLOGY - AREA B
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
06-TD100B
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/8" = 1'-0"
BUILDING 06 BASEMENT FLOOR DEMOLITION PLAN - TECHNOLOGY - AREA B
SHEET NOTES:
1. REMOVE ALL NETWORK CABLING TO POINTS
OF TERMINATION IN ASSOCIATED DATA
CLOSET. REFER TO FLOOR PLANS AND SHEET
T1001 FOR TR ROOM LOCATIONS.
2. REFER TO ARCHITECTURAL PHASING PLANS
FOR WHEN EXISTING CABLING IS ALLOWED TO
BE DEMOLISHED.
3. FOR ALL EXISTING WIRELESS ACCESS POINTS
AND SURVEILLANCE CAMERAS, DEVICES
SHALL REMAIN. SCOPE OF WORK INCLUDES
CABLE REPLACEMENT ONLY. COORDINATE
WITH COR FOR ANY DOWNTIME OF DEVICES.
4. EXISTING LOCATIONS OF WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT
NECESSARILY BE IN THE EXACT LOCATION AS
M P
D N
U P
U P
DN
U P
DN
DN
UP
UP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
D
U P
UP
SEALED
WINDOW
1D-WAP 1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D 1V
D
V
1D 1V
1D1V 2D1V
D
AREA B
AREA C - NORTH
AREA C - SOUTH
AREA C - NORTH
AREA C - SOUTH
AREA D
AREA B
AREA C - NORTH
AREA C - SOUTH
AREA C - NORTH
AREA C - SOUTH
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:5
P M
BUILDING 06 BASEMENT DEMO PLAN -
TECHNOLOGY - AREA C
PHINIE MAIBEJ
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES - MILWAUKEE, WI
SEPTEMBER 05, 2025
06-TD100C
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/8" = 1'-0"
BUILDING 06 BASEMENT FLOOR DEMOLITION PLAN - TECHNOLOGY - AREA C NORTH
KEYNOTES:
1. EXISTING COPPER BACKBONE ENTRY POINT,
PROTECT IN PLACE. CONDUIT IS ROUTED ON
CEILING TO WALL FIELD.
2. EXISTING COPPER WALL FIELD , PROTECT IN
PLACE.
1/8" = 1'-0"
BUILDING 06 BASEMENT FLOOR DEMOLITION PLAN - TECHNOLOGY - AREA C SOUTH
SHEET NOTES:
1. REMOVE ALL NETWORK CABLING TO POINTS
OF TERMINATION IN ASSOCIATED DATA
CLOSET. REFER TO FLOOR PLANS AND SHEET
T1001 FOR TR ROOM LOCATIONS.
2. REFER TO ARCHITECTURAL PHASING PLANS
FOR WHEN EXISTING CABLING IS ALLOWED TO
BE DEMOLISHED.
3. FOR ALL EXISTING WIRELESS ACCESS POINTS
AND SURVEILLANCE CAMERAS, DEVICES
SHALL REMAIN. SCOPE OF WORK INCLUDES
CABLE REPLACEMENT ONLY. COORDINATE
WITH COR FOR ANY DOWNTIME OF DEVICES.
4. EXISTING LOCATIONS OF WORK AREA
OUTLETS SHOWN ON THIS SHEET MAY NOT
NECESSARILY BE IN THE EXACT LOCATION AS
M P
U P
UP
UP
UP
UP
UP
UP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
1D-WAP
D
AREA C - NORTH
AREA C - SOUTH
AREA D
15 SUNNEN DRIVE
SUITE 104
ST. LOUIS, MO 63143
P: 314.645.1132 F: 314.645.1173
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #18004375.03
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
/8
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
35% SCHEMATIC DESIGN SUBMISSION 5.17.21
65% DESIGN DEVELOPMENT SUBMISSION 6.15.21
65% DESIGN DEVELOPMENT RESUBMISSION 8.25.21
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e
E H
R M
R
T
.0
V A
M ilw
E H
R M
C
.r v t
/3
/2
:5
:5
P M
BUILDING 06 BASEMENT DEMO PLAN -
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .