RFP Attachment 27 - Drawings 695-21-700 Part 20.pdf

PDF 9 MB Posted

Attached to
Y1DZ--EHRM Infrastructure Upgrades Tier 1 Construction 695-21-700 Milwaukee
Solicitation number
36C77626R0002
Issued by

About this file

This is a comprehensive set of architectural and engineering drawings for mechanical and electrical demolition and new work at the Clement J Zablocki VA Medical Center in Milwaukee, Wisconsin, as part of RFP 36C77626R0002 Project #695-21-700 EHRM Infrastructure Upgrades Tier 1 Construction. The drawings were prepared by Romanyk Consulting Corp. (Architect/Engineer of Record) and IMEG Corp. (Consultant) and issued as final bid documents on September 5, 2025.

The mechanical drawings detail demolition requirements for reverse osmosis tanks, surge tanks, deaerator tanks, and HVAC systems across multiple buildings (112, 123, and others). The electrical drawings document comprehensive demolition and new work for telecommunications rooms, electrical panels, lighting systems, fire alarm systems, and power distribution infrastructure across numerous buildings on the VA campus (Buildings 3-10, 20, 43, 70, 97, 102, 107-109, 111-113, 123, 144, 146-148). Key electrical work includes removal and replacement of panelboards, installation of new branch circuit panels rated 100A-225A at 120/208V for multiple telecommunications rooms, new receptacles and outlets, lighting fixture replacement with LED fixtures, fire alarm device coordination, and provisions for emergency and critical branch power systems. The drawings specify coordination requirements with mechanical contractors, temporary power provisions during construction, phasing schedules to maintain facility operations, and compliance with 2017 National Electrical Code. Materials are primarily specified as Squared-D or approved equal for panels and switchgear, with Eaton automatic transfer switches. The project requires hospital-grade receptacles, surge protection devices, lightning protection on generator enclosures, and detailed labeling and identification systems for all electrical equipment per VA specifications.

View the file

Other files

File Type Posted
36C77626R0002 Amendment 0006.pdf PDF
695-21-700 Technical Question Tracking Sheet - Milw EHRM FINAL 7-22-26.pdf PDF
695-21-700 Amend 5 CIVIL UPDATED Narrative 2026-07-17.pdf PDF
695-21-700 Amend 5 CIVIL UPDATED full set 2026-07-17.pdf PDF
36C77626R0002 Amendment 0004.pdf PDF
695-21-700 Spec and Drawing Narrative 7-10-26.pdf PDF
695-21-700 ARCH Full - 7-10-26.pdf PDF
695-21-700 PLUMB Full - 7-10-26.pdf PDF
695-21-700 CIVIL Full - 7-10-26.pdf PDF
695-21-700 Tech Qtn Tracking Sheet - Milw EHRM FINAL 7-15-26.pdf PDF
695-21-700 Specs Part 1 - 7-10-26.pdf PDF
695-21-700 Specs Part 3 - 7-10-26.pdf PDF
695-21-700 TECH Full - 7-10-26.pdf PDF
36C77626R0002 Amendment 0003.pdf PDF
36C77626R0002 Amendment 0002.pdf PDF
695-21-700 Site Visit Sign In Sheet 5-6-2026.pdf PDF
AMENDED RFP Attachment 2 - Site Visit - Milwaukee.pdf PDF
36C77626R0002 Amendment 0001.pdf PDF
RFP 36C77626R0002.pdf PDF
RFP Attachment 2A - Site Visit Campus Map - Milwaukee.pdf PDF
RFP Attachment 5 - Specs 695-21-700 Part 1.pdf PDF
RFP Attachment 8 - Drawings 695-21-700 Part 1.pdf PDF
RFP Attachment 11 - Drawings 695-21-700 Part 4.pdf PDF
RFP Attachment 13 - Drawings 695-21-700 Part 6.pdf PDF
RFP Attachment 18 - Drawings 695-21-700 Part 11.pdf PDF
RFP Attachment 20 - Drawings 695-21-700 Part 13.pdf PDF
RFP Attachment 22 - Drawings 695-21-700 Part 15.pdf PDF
RFP Attachment 28 - Drawings 695-21-700 Part 21.pdf PDF
RFP Attachment 30 - Drawings 695-21-700 Part 23.pdf PDF
RFP Attachment 35 - Project Information Sheet for Contractors.docx DOCX document
RFP Attachment 3 - Division Cost Breakdown - Milwaukee.xlsx XLSX spreadsheet
RFP Attachment 9 - Drawings 695-21-700 Part 2.pdf PDF
RFP Attachment 10 - Drawings 695-21-700 Part 3.pdf PDF
RFP Attachment 14 - Drawings 695-21-700 Part 7.pdf PDF
RFP Attachment 21 - Drawings 695-21-700 Part 14.pdf PDF
RFP Attachment 26 - Drawings 695-21-700 Part 19.pdf PDF
RFP Attachment 2 - Site Visit - Milwaukee.pdf PDF
RFP Attachment 7 - Specs 695-21-700 Part 3.pdf PDF
RFP Attachment 12 - Drawings 695-21-700 Part 5.pdf PDF
RFP Attachment 16 - Drawings 695-21-700 Part 9.pdf PDF
RFP Attachment 19 - Drawings 695-21-700 Part 12.pdf PDF
RFP Attachment 23 - Drawings 695-21-700 Part 16.pdf PDF
RFP Attachment 24 - Drawings 695-21-700 Part 17.pdf PDF
RFP Attachment 25 - Drawings 695-21-700 Part 18.pdf PDF
RFP Attachment 32 - Drawings 695-21-700 Part 25.pdf PDF
RFP Attachment 36 - PPQ.docx DOCX document
RFP Attachment 1 - DBA Rates - Milwaukee County - 1-2-26.pdf PDF
RFP Attachment 4 - Limitations on Subcontracting - Milwaukee.docx DOCX document
RFP Attachment 6 - Specs 695-21-700 Part 2.pdf PDF
RFP Attachment 15 - Drawings 695-21-700 Part 8.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REVERSE OSMOSIS TANK

SURGE TANK

DEAERATOR TANK

UP DN

DN

UP

DN

UP

DN

KEY NOTES #

1. THERE ARE NO MECHANICAL SYSTEMS IN THIS AREA TO BE DEMOLISHED.

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

G ra p h ic S c a le

/1

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3

/2

:2

:1

A

M

BLDG 112 - FIRST FLOOR OVERALL & ENLARGED

- MECHANICAL DEMOLITION

AGW HWG

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

112-MD101

5000 W. NATIONAL AVENUE MILWAUKEE, WI

1/8" = 1'-0"

BLDG 112 - FIRST FLOOR - OVERALL MECHANICAL DEMOLITION

1/2" = 1'-0"

BLDG 112 - FIRST FLOOR - ENLARGED MECHANICAL DEMOLITION - ROOM 115

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

Revisions: Date:

PROFESSIONAL ENGINEER

WISCONSIN

ARLO G.

WIECZOREK

#42666-6

SWISHER

IOWA

9/5/25

REVERSE OSMOSIS TANK

SURGE TANK

DEAERATOR TANK

UP DN

DN

UP

DN

UP

DN

KEY NOTES #

112-MH101

112-AC-108

T

112-ACCU-108

REF

1. ROUTE REFRIGERANT PIPE LOW ALONG WALL, THEN OUT AND DOWN EXTERIOR

WALL TO CONDENSING UNIT.

2. TEMPERATURE CONTROLS. REFERENCE MECHANICAL CONTROL PLANS FOR

CONTROLS AND MONITORING.

3. SHADED AREA INDICATES RECOMMENDED 36" CLEARANCE FOR DX UNIT.

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

G ra p h ic S c a le

/1

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3

/2

:2

:1

A

M

BLDG 112 - FIRST FLOOR OVERALL AND

ENLARGED - MECHANICAL

AGW HWG

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

112-MH101

5000 W. NATIONAL AVENUE MILWAUKEE, WI

1/8" = 1'-0"

BLDG 112 - FIRST FLOOR - OVERALL MECHANICAL

1/2" = 1'-0"

BLDG 112 - FIRST FLOOR - ENLARGED PLAN MECHANICAL

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02Revisions: Date:

PROFESSIONAL ENGINEER

WISCONSIN

ARLO G.

WIECZOREK

#42666-6

SWISHER

OV E R H E A D D OO R

L O U V E R WI N D O W

L O U V E R WI N D O W

OV E R H E A D D OO R

L O U V E R WI N D O W

L O U V E R WI N D O W

HALLWAY

MED RM

HALLWAY

MED RM

KEY NOTES #

123-MD101

123-MD101

123-MD101

123-MD101

123-MD101

TELECOMMUNICATIONS RM.

B113

CIO

D113

1. DEMOLISH GRILLE AND DUCT BRANCH. CAP DUCT AT MAIN CONNECTION

OUTSIDE OF ROOM.

0' 15' 30' 60'

Graphic Scale : 1" = 30'-0"

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a le

/1

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3

/2

:2

:1

A

M

BUILDING 123 LEVEL 01 - MECHANICAL

DEMOLITION PLAN

AGW HWG

FINAL BID DOCUMENTS 695-21-700

EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

123-MD101

5000 W. NATIONAL AVENUE MILWAUKEE, WI

1" = 30'-0"

BUILDING 123 LEVEL 01 FLOOR PLAN - MECHANICAL DEMOLITION

1/4" = 1'-0"

RM. B113 ENLARGED PLAN -

MECHANICAL DEMOLITION

1/4" = 1'-0"

RM. A107 ENLARGED PLAN -

MECHANICAL DEMOLITION

1/4" = 1'-0"

RM. C113 ENLARGED PLAN -

MECHANICAL DEMOLITION

1/4" = 1'-0"

RM. D113 ENLARGED PLAN -

MECHANICAL DEMOLITION

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1/4" = 1'-0"

RM. E105E ENLARGED PLAN -

MECHANICAL DEMOLITION

Revisions: Date:

PROFESSIONAL ENGINEER

WISCONSIN

ARLO G.

WIECZOREK

#42666-6

SWISHER

T

T

T

OV E R H E A D D OO R

L O U V E R WI N D O W

L O U V E R WI N D O W

OV E R H E A D D OO R

L O U V E R WI N D O W

L O U V E R WI N D O W

KEY NOTES #

123-AC-A107

A107

TELECOMMUNICATIONS

RM.

123-ACCU-A107

R E

F

REF

REF

B113

TELECOMMUNICATIONS

RM.

123-ACCU-B113 4

123-AC-B113

REF

C113

TELECOMMUNICATIONS

RM.

123-AC-C113

R E

F

REF

123-ACCU-C113

D113

TELECOMMUNICATIONS

RM.

123-ACCU-D113

123-AC-D113

REF

T

E105E

TELECOMMUNICATIONS

RM.

123-AC-E105E

123-ACCU-E105E

REF

T

123-MH101

123-MH101

123-MH101

123-MH101

123-MH101

1. TEMPERATURE CONTROL. REFERENCE MECHANICAL CONTROL PLANS FOR

CONTROLS AND MONITORING.

2. ROUTE REFRIGERANT PIPING ABOVE CEILING AND UP THROUGH ROOF. PROVIDE

SEALED ROOF BOOT AND SEAL EXTERIOR PENETRATIONS WEATHER TIGHT.

3. HATCHED AREA INDICATES MANUFACTURER'S RECOMMENED CLEARANCE FOR

THE EQUIPMENT.

4. MOUNT CONDENSING UNIT ON ROOF ABOVE AT APPROXOMATE LOCATION

SHOW. COORDINATE EXACT LOCATION WITH EXISTING ROOF PENETRATIONS,

ROOF DRAINAGE, AND EQUIPMENT. PROVIDE GUARDRAILS AROUND

CONDENSING UNIT IF WITHIN 10'-0" OF ROOF EDGE.

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a le

/1

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/3

/2

:2

:2

A

M

BUILDING 123 LEVEL 01 - MECHANICAL PLAN

AGW HWG

FINAL BID DOCUMENTS 695-21-700EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

123-MH101

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1/4" = 1'-0"

RM. A107 ENLARGED PLAN - MECHANICAL

1/4" = 1'-0"

RM. B113 ENLARGED PLAN - MECHANICAL

1/4" = 1'-0"

RM. C113 ENLARGED PLAN - MECHANICAL

1/4" = 1'-0"

RM. D113 ENLARGED PLAN - MECHANICAL

1/4" = 1'-0"

RM. E105E ENLARGED PLAN - MECHANICAL

1" = 30'-0"

BUILDING 123 LEVEL 01 FLOOR PLAN - MECHANICAL

Revisions: Date:

PROFESSIONAL ENGINEER

WISCONSIN

ARLO G.

WIECZOREK

#42666-6

SWISHER

ELECTRICAL PHASING NOTES

ELECTRICAL SCOPE OF WORK

ELECTRICAL DEMOLITION NOTESELECTRICAL ABBREVIATIONS

ELECTRICAL LEGEND NOTES

ELECTRICAL GENERAL NOTES

DRAWING SYMBOLS

LIGHTING GENERAL NOTES

LIGHTING SYMBOLS

FIRE ALARM GENERAL NOTES

SCOPE OF WORK

POWER SYMBOLS

FIRE ALARM SYMBOLS

ELECTRICAL EQUIPMENT NOTES

1. ALL LIGHT FIXTURES MAY HAVE AN EQUAL BUT REQUIRE APPROVAL BY ENGINEER AND OWNER. ALL LIGHT FIXTURE PRIOR APPROVALS MUST BE IN WRITING. THE ENGINEER RESERVES THE RIGHT TO REQUIRE “TABLE

TOP” TESTING OF ANY FIXTURE SUBMITTED AS AN EQUAL.

2. ALL RECESSED LIGHTING FIXTURES MUST BE INSTALLED TO PROVIDE A NON-COMBUSTIBLE FIRE RATED

ASSEMBLY.

3. COORDINATE ALL LIGHT FIXTURE MOUNTING REQUIREMENTS WITH REFLECTED CEILING PLAN PRIOR TO

RELEASE OF FIXTURE.

4. ELECTRICAL CONTRACTOR SHALL NOT SHARE NEUTRALS, UNLESS SPECIFICALLY NOTED OTHERWISE. ALL LIGHTING CIRCUITS SHALL HAVE A SEPARATE INSULATED GROUNDING CONDUCTOR INSTALLED WITH EACH

CIRCUIT.

5. ALL LIGHT FIXTURES SHOWN AS HALFTONE ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE.

1' x 4' STRIP LIGHT FIXTURE

1' x 4' STRIP LIGHT FIXTURE WITH EMERGENCY POWER

SWITCH: SINGLE POLE, SINGLE THROW, 120/277 VOLT, 20 AMP

OS OCCUPANCY SENSOR, DUAL TECHNOLOGY, WALL MOUNT

2' X 4' LIGHT FIXTURE WITH EMERGENCY POWER

DOWNLIGHT

DOWNLIGHT WITH EMERGENCY POWER

1. EXISTING FIRE ALARM SYSTEM SHALL STAY OPERATIONAL DURING CONSTRUCTION. PROVIDE NEW OR

TEMPORARY FIRE ALARM DEVICES AS NEEDED PER NFPA AND VA CODE AND REGULATIONS.

2. EXISTING FIRE ALARM SYSTEM IS SIEMENS XLS. NEW FIRE ALARM DEVICES WILL CONNECT TO EXISTING FIRE

ALARM SYSTEM. PROVIDE NEW FIRE ALARM DEVICES TO MATCH EXISTING SYSTEM.

3. EXISTING FIRE ALARM SYSTEM ZONES SHALL BE TESTED PRIOR TO CONNECTING NEW DEVICES. EXPAND

EXISTING FIRE ALARM SYSTEM AS REQUIRED DOE PROPER OPERATION AND FUNCTION.

4. THE EXISTING FIRE ALARM SYSTEM IS A SIMPLEX SYSTEM. THE SERVICE CONTRACTOR IS GRUNAU COMPANY.

CONTACT ERIK KRALOVITZ (PHONE - 414-406-0403). IT IS RECOMMENDED THAT THE EXISTING FIRE SERVICE CONTRACTOR BE INCLUDED AS PART OF THE NEW FIRE ALARM WORK TO RETAIN THE KNOWLEDGE OF THE

SYSTEM.

5. FIRE ALARM DEVICES ARE INDICATED FOR DESIGN INTENT. DEVICE QUANTITIES INDICATED ARE MINIMUM.

PROVIDE ADDITIONAL DEVICES AS REQUIRED IN THE RENOVATION SPACES.

6. IN CONSTRUCTION AREAS REPLACE ALL SMOKE DETECTORS WITH HEAT DETECTORS DURING

CONSTRUCTION. INSTALL NEW SMOKE DETECTORS AT SAME LOCATION OF EXISTING SMOKE DETECTORS

AFTER CONSTRUCTION IN THE AREAS.

2' X 4' LIGHT FIXTURE

NO SCOPE OF WORK ASSOCIATED IN HATCHED AREA, TYPICAL OF ALL ELECTRICAL SHEETS.

RECEPTACLE, DUPLEX

RECEPTACLE, DUPLEX ON EMERGENCY POWER

RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER

RECEPTACLE, DUPLEX WITH DIECAST WEATHERPROOF IN USE COVERPLATE WITH

GROUND FAULT CIRCUIT INTERRUPTER. WATER RESISTANT IN EXTERIOR LOCATIONS

MOUNT 48" AFF.

RECEPTACLE, QUADRAPLEX

RECEPTACLE, QUADRAPLEX ON EMERGENCY POWER

RECEPTACLE, SINGLE

RECEPTACLE, SPECIAL PURPOSE:

REFER TO DRAWING NOTES FOR TYPE

RECEPTACLE, SPECIAL PURPOSE ON EMERGENCY POWER:

REFER TO DRAWING NOTES FOR TYPE

JUNCTION BOX, WALL/CEILING/FLOOR MOUNTED:

SIZE PER N.E.C., REFER TO SPECIFICATIONS FOR GENERAL CONSTRUCTION, SYMBOL

DOES NOT INDICATE ALL JUNCTION BOXES THAT ARE REQUIRED FOR THIS PROJECT

ARE SHOWN ON PLAN(S).

PULL BOX

SWITCHBOARD

PANELBOARD

TRANSFORMER

DISCONNECT SWITCH, UNFUSED

DISCONNECT SWITCH, FUSED

STARTER, COMBINATION WITH DISCONNECT SWITCH

STARTER OR MOTOR CONTROLLER

MOTOR RATED TOGGLE SWITCH WITH OVERCURRENT PROTECTION

MOTOR, SINGLE-PHASE

MOTOR, THREE-PHASE

WYE CONNECTION

EARTH GROUND

T

PB

J J

GFI

J

NOTES:

1. LETTER OR NUMBER DENOTES FIXTURE TYPE, REFER TO LIGHTING FIXTURE SCHEDULE AND LIGHTING PLANS

FOR DETAILS.

2. ALL SYMBOLS SHOWN WITH DASHED LINES DENOTES THAT FIXTURES ARE TO BE REMOVED - THIS APPLIES

ONLY TO DEMOLITION SHEETS.

1. THE EXISTING CAMPUS SUPPORT CENTER (MAIN SERVER ROOM), MAIN TELEPHONE EQUIPMENT ROOM, AND TR ROOMS WILL NEED TO REMAIN OPERATIONAL DURING CONSTRUCTION. EXISTING ELECTRICAL PANELS AND CONNECTIVITY SHALL REMAIN. PROVIDE TEMPORARY ELECTRICAL PANELS AND CIRCUITS WHERE EXISTING ELECTRICAL PANELS WILL BE AFFECTED. COORDINATE WITH VA COR AND SCHEDULES FROM

OTHER TRADES FOR EXACT ELECTRICAL WORK.

2. COORDINATE WITH THE VA FOR ELECTRICAL WORK PHASES. IN GENERAL, LONG LEAD TIME ITEMS, SUCH AS NEW ELECTRICAL SUBSTATION, ELECTRICAL EQUIPMENT SERVING ICC, NEW DISTRIBUTION TYPE EQUIPMENT, AND NEW GENERATOR AND RELATED SITE ELECTRICAL WORK SHALL BE PERFORMED AHEAD OF OTHERS

WORK.

3. NEW ELECTRICAL SUBSTATION IN BUILDING 111 SERVES NEW TR ROOMS, MCR, AND DEMARC ROOMS.

COORDINATE WITH CONSTRUCTION IN MCR AREA FOR POWER EQUIPMENT AND FEEDERS PHASING NEEDS.

4. ELECTRICAL DEMOLITION WORK IN NEW TR SPACES SHALL FOLLOW OTHER DISCIPLINES' WORK SCHEDULES.

5. ELECTRICAL EQUIPMENT SHALL BE DE-ENERGIZED BEFORE WORKING ON THEM. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE VA COR FOR EXISTING ELECTRICAL SYSTEM TIE-INS AND SYSTEM DOWNTIME

NEEDED. PROVIDE SCHEDULE TO VA COR AT LEAST TWO WEEKS PRIOR TO ELECTRICAL WORK.

6. PERFORM ELECTRICAL WORK IN WEEKENDS AND EVENINGS AS NEEDED TO REDUCE INTERRUPTION OF

FACILITY'S NORMAL OPERATION.

1' x 4' STRIP LIGHT FIXTURE

VERTICALLY MOUNTED AT 2'0" AFF

1' x 4' STRIP LIGHT FIXTURE WITH EMERGENCY POWER

VERTICALLY MOUNTED AT 2'0" AFF

1. BUILDING 111 - NEW POWER DISTRIBUTION SYSTEMS FOR 2N POWER FOR THE NEW ICC ROOM AND ALL NEW TR ROOMS. THE 2N UPS SERVES POWER FOR THE ICC, FUTURE SERVER ROOM, AND ALL NEW TR ROOMS.

2. BUILDING 146, 147, AND 148 - DEMOLISH THE EXISTING GENERATORS, NEW OUTDOOR GENERATOR FOR ALL THREE BUILDINGS. EXISTING TRANSFER SWITCHES, UTILITY CONNECTIONS AND SECONDARY DISTRIBUTION

WILL BE REUSED.

3. OTHER BUILDINGS - 2N PANELBOARDS ARE INCLUDED FOR ALL TR ROOMS. EXISTING BUILDING POWER

SYSTEM DISTRIBUTION EQUIPMENT WILL BE MODIFIED TO SERVE THE NEW 2N PANEL.

4. 2N PANELS IN EACH NEW TR ROOM - ONE PANEL WILL BE FED FROM THE GENERATOR POWER DISTRIBUTION, AND THE SECOND PANEL WILL BE FED FROM THE UTILITY POWER DISTRIBUTION.

5. NEW TR ROOMS - WORK INCLUDES NEW WALL OUTLETS, NEW 208V, 3 PHASE OUTLETS FOR RACK UPS POWER, UPS, ZONE POWER SUPPLIES, NEW LED LIGHTING, NEW LIGHTING CONTROLS, POWER CONNECTION

FOR NEW HVAC EQUIPMENT, AND NEW FIRE ALARM DEVICE.

6. ELECTRICAL DEMOLITION IN EXISTING SPACES WHICH WILL BE USED FOR TR ROOMS - WALL OUTLETS, POWER PANELS, AND LIGHTING WILL BE DISCONNECTED AND REMOVED.

7. REMOVE ALL UNUSED CONDUITS IN AND OUT OF THE NEW TR ROOMS.

8. CABLE TRAY AND RACK LOCATIONS SHOWN ON ELECTRICAL SHEETS ARE FOR REFERENCE ONLY. SEE "T"

SERIES SHEETS FOR DETAILS.

9. HVAC EQUIPMENT SHOWN ON ELECTRICAL SHEETS ARE FOR REFERENCE ONLY.

10. ARCHITECTURAL BACKGROUND ON ELECTRICAL SHEETS SHOWING DEMOLITION AND NEW ITEMS ARE FOR

REFERENCE ONLY.

11. ACCESSING TO DATA CLOSETS MUST BE COORDINATED WITH COR TO AVOID IMPACT TO ED, ICU, ORS, AND

MENTAL HEALTH.

12. CONTRACTOR SHALL PLAN FOR AFTER HOURS SHIFT (AFTER 5OM AND BEFORE 5AM) WORK ON 1ST, 2ND, AND LEVEL 03S.

3 SWITCH: THREE WAY, 120/277 VOLT 20 AMP

WP

SD FIRE ALARM SMOKE DETECTOR, CEILING MOUNT

FIRE ALARM HORN/STROBE, WALL MOUNT

FIRE ALARM STROBE, WALL MOUNT

FIRE ALARM RELAY

F

F

2' X 2' LIGHT FIXTURE WITH EMERGENCY POWER

2' X 2' LIGHT FIXTURE

1' x 2' STRIP LIGHT FIXTURE

1' x 2' STRIP LIGHT FIXTURE WITH EMERGENCY POWER

FAR

LED WALL MOUNTED WALLPACK

T

LV LOW VOLTAGE SWITCH

1. ALL ELECTRICAL ITEMS INSTALLED IN WALLS, FLOORS, OR CEILINGS TO BE DEMOLISHED SHALL BE REMOVED IN THEIR ENTIRETY UNLESS OTHERWISE NOTED OR REQUIRED BY OTHER CONDITIONS IN THESE DOCUMENTS. SEE DRAWINGS OF ALL OTHER TRADES FOR EXTENT OF DEMOLITION WORK. ELECTRICAL ITEMS SHALL INCLUDE POWER, LIGHTING, AND SPECIAL SYSTEMS. REFER ALL QUESTIONS OF APPLICABILITY TO THE A/E PRIOR TO BID

FOR CLARIFICATION; OTHERWISE, FIELD DECISIONS BY THE A/E SHALL BE BINDING.

2. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE SCOPE OF THE DEMOLITION WORK AND THAT NOT ALL ITEMS OF ELECTRICAL DEMOLITION ARE NECESSARILY SHOWN. THE CONTRACTOR SHALL BE REQUIRED TO FIELD VERIFY AND FIELD DETERMINE THE SCOPE OF THE DEMOLITION WORK PRIOR TO BID. REFER

ALL QUESTIONS TO THE A/E PRIOR TO BID FOR CLARIFICATION.

3. PHASING OF ELECTRICAL DEMOLITION SHALL FOLLOW THAT OF THE GENERAL CONTRACTOR. COORDINATE REMOVAL OF ELECTRICAL WORK WITH OTHER CONSTRUCTION ACTIVITIES AND THE REQUIREMENTS OF THE

OWNER.

4. THE OWNER SHALL HAVE SALVAGE RIGHTS TO ANY ITEMS THAT ARE TO BE DEMOLISHED. ITEMS SUCH AS SPEAKERS AND CAMERAS AND OTHER ITEMS THAT THE OWNER WISHES TO SALVAGE SHALL BE CAREFULLY REMOVED AND STORED IN A LOCATION AS DIRECTED BY THE OWNER. ALL OTHER ITEMS OF DEMOLITION SHALL

BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE.

5. WHERE DEMOLITION WORK WILL INTERRUPT CIRCUIT CONTINUITY TO OTHER AREAS OF THE FACILITY THAT ARE TO REMAIN IN OPERATION, THEN RACEWAY AND WIRING SHALL BE INSTALLED TO MAINTAIN THOSE AREAS IN COMPLETE OPERATION. PROVIDE TEMPORARY CONNECTIONS AS REQUIRED. CONTRACTOR SHALL SUBMIT A REQUEST FOR ANY INTERRUPTIONS OR OUTAGES TO THE OWNER AT LEAST FIFTEEN (15) WORKING DAYS IN

ADVANCE AND ACCOMMODATE THE OWNER'S NEEDS AS REQUIRED.

6. ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY. CONDUCTORS SHALL BE REMOVED FROM THE ITEM TO BE DEMOLISHED TO THE SOURCE OVERCURRENT DEVICE. RACEWAYS WHICH ARE INSTALLED IN OR BELOW FLOORS OR WITHIN WALLS MAY BE ABANDONED, BUT ALL OVERHEAD OR EXPOSED RACEWAYS SHALL BE REMOVED. EXPOSED RACEWAYS TO BE ABANDONED SHALL BE REMOVED AND SHALL BE CUT OR CHISELED AT LEAST 2"" INTO THE WALL OR FLOOR AND THE OPENING GROUTED SMOOTH.

7. WHERE EXISTING DEVICE OR JUNCTION BOXES MUST REMAIN IN EXISTING WALLS OR CEILINGS (SUCH AS FOR CIRCUITS THAT MUST BE MAINTAINED TO OTHER AREAS), THEN THEY SHALL BE FITTED WITH BLANK

COVERPLATES.

8. WHERE DISTRIBUTION OR BRANCH CIRCUIT EQUIPMENT (PANELBOARDS, SWITCHBOARDS, ETC.) IS TO BE REMOVED, THEN ALL CIRCUITS WHICH FEED ITEMS TO REMAIN SHALL BE RECONNECTED TO NEW DISTRIBUTION

OR BRANCH CIRCUIT EQUIPMENT. REFER ALL QUESTIONS TO THE A/E FOR CLARIFICATION.

9. IF HAZARDOUS MATERIALS (I.E. ASBESTOS, PCB's, ETC.) ARE ENCOUNTERED AT ANY TIME DURING CONSTRUCTION IN THE WORK AREA, STOP WORK IMMEDIATELY AND CONTACT THE A/E OR THE OWNER.

10. REMOVE ALL DEVICES SHOWN ON DEMOLITION PLAN UNLESS OTHERWISE NOTED.

11. REMOVE CABLING BACK TO SOURCE FOR ALL TEL/DATA OUTLETS BEING REMOVED.

12. ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR UPDATING SCHEDULES FOR ANY SWITCHBOARDS AND

PANELBOARDS THAT ARE AFFECTED BY THIS PROJECT AND ARE TO BE TYPEWRITTEN.

13. THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR REQUIRED WORK OUTSIDE THIS PROJECT BOUNDARY NECESSARY TO ENSURE ADJACENT SERVICES REMAIN ENERGIZED DURING CONSTRUCTION OF THE

RENOVATION PROJECT.

14. ALL EXISTING BRANCH CIRCUITS NOT USED ARE TO BE REMOVED BACK TO THE PANEL. THE CIRCUIT BREAKERS ARE TO BE LABELED AS SPARE. EXISTING CONDUITS FROM PANEL ARE TO REMAIN TO ABOVE CEILING.

15. ELECTRICAL CONTRACTOR TO PROVIDE COVERS FOR ANY EXISTING OPEN BUSSING IN PANELBOARDS THAT ARE

AFFECTED BY THIS PROJECT.

16. ELECTRICAL CONTRACTOR TO REMOVE ANY AND ALL UNUSED OR ABANDONED ELECTRICAL EQUIPMENT THAT

RESIDES WITHIN THE AREAS OF THE PROJECT SCOPE.

17. REPAIR OR REPLACE BUILDING ELEMENTS WHICH ARE DAMAGED AS PART OF DEMOLITION WORK.

18. DISCONNECT MECHANICAL EQUIPMENT BEING REMOVED BY MECHANICAL CONTRACTOR. COORDINATE

EQUIPMENT REMOVAL LOCATIONS WITH MECHANICAL DRAWINGS.

19. COORDINATE DEMOLITION WITH THE WORK OF OTHER TRADES.

20. PROVIDE BLANK COVERPLATES FOR ABANDONED RECESSED JUNCTION BOXES.

21. COORDINATE DEMOLITION OF TELECOMMUNICATIONS CABLING WITH OWNER AND GENERAL CONTRACTOR.

22. COORDINATE ANY AND ALL OUTAGES AT LEAST 14 DAYS WITH THE OWNER PRIOR TO ANY DISRUPTION OF

POWER.

23. EXISTING ELECTRICAL SYSTEM IS TO REMAIN IN SERVICE UNLESS OTHERWISE NOTED. ALL CIRCUITS WHICH ARE DISTURBED BY DEMOLITION OR NEW CONSTRUCTION ARE TO BE RECONNECTED AT NO ADDITIONAL COST TO

THE OWNER.

24. REMOVE ALL DEVICES INDICATED BY DARKENED OR DASHED LINES AND ASSOCIATED KEYED NOTES. REMOVE ALL DEVICES IN WALLS AND CEILINGS WHICH ARE SHOWN TO BE DEMOLISHED ON ARCHITECTURAL PLANS, WHETHER OR NOT SUCH DEVICES ARE SHOWN ON THESE PLANS.

25. REMOVE ALL DEVICES, CONDUIT AND CONDUCTORS COMPLETE TO SOURCE ASSOCIATED WITH MECHANICAL EQUIPMENT WHICH IS BEING DEMOLISHED. COORDINATE WITH MECHANICAL PLANS FOR DETAILED INFORMATION.

26. WHERE CIRCUITS ARE REMOVED COMPLETELY, RELABEL EXISTING CIRCUIT BREAKER AS "SPARE".

27. EXISTING LIGHTING AND LIGHTING CONTROLS ARE TO REMAIN UNLESS OTHERWISE NOTED ON THE LIGHTING

PLANS.

1PH SINGLE-PHASE

1P SINGLE POLE

2/C TWO-CONDUCTOR

3/C THREE-CONDUCTOR

3PH THREE-PHASE

4/C FOUR-CONDUCTOR

4W FOUR-WIRE

A/C UNIT AIR CONDITIONING UNIT

AAP ALARM ANNUNCIATOR PANEL

AC ALTERNATING CURRENT OR ARMORED CABLE

ACC ACCESSIBLE

ADDL ADDITIONAL

ADJ ADJACENT, ADJOINING

AF AMPERE FRAME OR AMP FUSE

AFC ABOVE FINISHED COUNTER

AFCI ARC-FAULT CURRENT INTERRUPTER

Ah AMPERE HOUR

AHJ AUTHORITY HAVING JURISDICTION

AIC AMPERE INTERRUPTING CAPACITY

ALT ALTERNATE AMP AMPERE

ASC AMPS SHORT CIRCUIT

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AV AUDIO VISUAL

BAT BATTERY

BD BOARD

BFF BELOW FINISH FLOOR

BRKR BREAKER

BYP BY PASS

C CONDUIT

CAB CABINET

CALC CALCULATE

CAP CAPACITY

CAT CATALOG

CATV COMMUNITY ANTENNA TELEVISION

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TELEVISION

cd CANDELA

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED

CFE CONTRACTOR FURNISHED EQUIPMENT

CHW CHILLED WATER

CHWP CHILLED WATER PUMP

CKT CIRCUIT

CKT BRKR CIRCUIT BREAKER OR C/B

CLF CURRENT LIMITING FUSE CLG CEILING

COAX COAX CABLE

COMM COMMUNICATION

COMPT COMPARTMENT

CONC CONCRETE

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

CPT CONTROL POWER TRANSFORMER

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CU COPPER

CUR CURRENT

DC DIRECT CURRENT

DCP DIMMER CONTROL PANEL

DIAG DIAGRAM

DISC DISCONNECT

DISTR PNL DISTRIBUTION PANEL

DMR SW DIMMER SWITCH

DPDT DOUBLE POLE, DOUBLE THROW

DPST DOUBLE POLE, SINGLE THROW

DRSW DOOR SWITCH DS DISCONNECT SWITCH

E EMERGENCY

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATOR

EMER EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EPO EMERGENCY POWER OFF

EPRF EXPLOSION PROOF

ESC ESCUTCHEON

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EX EXISTINGS

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FIXT FIXTURE

FLA FULL LOAD AMPS

FLUOR FLUORESCENT

FP FIRE PROTECTION

FU SW FUSED SWITCH

FVNR FULL VOLTAGE NON-REVERSING

FVR FULL VOLTAGE REVERSING

G ELECTRICAL GROUND

GEN GENERATOR

GFI GROUND FAULT CIRCUIT INTERRUPTER

H HOSPITAL GRADE

HID HIGH INTENSITY DISCHARGE

HOA HAND-OFF-AUTOMATIC

IG ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUIT

INCAND INCANDESCENT

IR INFRARED

J-BOX JUNCTION BOX

kV KILOVOLT kVA KILOVOLT AMPERE kVAh KILOVOLT AMPERE PER HOUR kVAR KILOVOLT AMPERE REACTIVE kW KILOWATT kWh KILOWATT HOUR kWhM KILOWATT HOUR METER

LED LIGHT EMITTING DIODE

LPS LOW PRESSURE SODIUM

LRA LOCKED ROTOR AMPS

LT LIGHT

LTG LIGHTING

LTG PNL LIGHTING PANEL

LTNG LIGHTNING

LV LOW V OLTAGE

MC METAL-CLAD

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MOCP MAXIMUM OVERCURRENT

PROTECTION

MLO MAIN LUGS ONLY

MT MOUNT MTD MOUNTED

MTG MOUNTING

MTS MANUAL TRANSFER SWITCH

MV MEDIUM VOLTAGE

MVA MEGAVOLT-AMPERE

MW MEGAWATT

NC NORMALLY CLOSED

NEUT NEUTRAL (OR N)

NL NIGHT LIGHT

NO NORMALLY OPEN

OL OVERLOAD

P POLE

PB PULL BOX

RCP REFLECTED CEILING PLAN

PEC PHOTOELECTRIC CELL

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PNL PANEL

PT POTENTIAL TRANSFORMER

PTZ PAN, TILT, ZOOM TYPE CAMERA

PVC POLYVINYL CHLORIDE (PLASTIC)

PWR POWER

REC RECESSED

RECEP RECEPTACLE

RMS ROOT MEAN SQUARE

SCC SHORT CIRCUIT CAPACITY

SD SMOKE DETECTOR

SPST SINGLE POLE, SINGLE THROW

SURF SURFACE

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

T TAMPER RESISTANT

TEL TELEPHONE

TV TELEVISION

UFD UNDERFLOOR DUCT

UGND UNDERGROUND

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER

SUPPLY

V VOLT

VA VOLT AMPERE

VAR VOLT AMPERE REACTIVE

VFD VARIABLE FREQUENCY DRIVE

VOLT VOLTAGE

W WALL MOUNTEDS

WH WATER HEATER

WP WEATHERPROOF

XFMR TRANSFORMER

1. ALL SYMBOLS INDICATED ARE NOT NECESSARILY USED ON PLANS.

2. ALL MOUNTING DIMENSIONS GIVEN ARE TO THE CENTERLINE (CL) OF THE DEVICE AND ABOVE FINISHED FLOOR

(A.F.F.) OR ABOVE FINISHED GRADE (A.F.G.) UNLESS OTHERWISE NOTED.

3. WALL MOUNTED LIGHT SWITCHES ARE TO BE LOCATED 46" A.F.F. AND 2" FROM EDGE OF DOOR FRAME TO EDGE

OF DEVICE PLATE.

4. OUTLETS INDICATED AS BEING FOR WALL MOUNTED TELEPHONES SHALL BE LOCATED 54" A.F.F. UNLESS

OTHERWISE NOTED.

5. WALL MOUNTED FIRE ALARM MANUAL PULL STATIONS ARE TO BE LOCATED 46" A.F.F. AND WITHIN 72" OF THE

NEAREST ADJACENT EXIT DOOR FROM THE FLOOR OR BUILDING.

6. FIRE ALARM VISUAL NOTIFICATION APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE LENS IS BETWEEN

80" AND 96" A.F.F..

7. CONVENIENCE OUTLETS SHALL BE MOUNTED 18" A.F.F. AND SHALL BE ALIGNED VERTICALLY. PROVIDE HORIZONTAL INSTALLATIONS ONLY WHEN SPACE IS LIMITED, SUCH AS BETWEEN MIRRORS AND CABINET

BACKSPLASHES. THE GROUND PIN SHALL BE ORIENTED IN THE UP POSITION.

8. CONVENIENCE OUTLETS LOCATED IN MECHANICAL AND BOILER ROOMS SHALL BE LOCATED 46" A.F.F.

9. CONVENIENCE OUTLETS LOCATED OUTSIDE SHALL BE GFI AND WEATHERPROOF RATED, FURNISHED WITH A WEATHERPROOF "WHILE-IN- USE" COVER AND MOUNTED 24" A.F.F. OR A.F.G.. EXTERIOR CONVENIENCE OUTLETS SHALL BE INSTALLED WITHIN 25 FEET AND ON THE SAME LEVEL AS HEATING, AIR CONDITIONING AND

REFRIGERATION EQUIPMENT.

10. OUTLETS FOR WALL MOUNTED TELECOMMUNICATIONS OR COMPUTER DEVICES SHALL BE LOCATED 18" A.F.F.

AND SHALL BE ALIGNED VERTICALLY. PROVIDE HORIZONTAL INSTALLATIONS ONLY WHEN SPACE IS LIMITED, SUCH AS BETWEEN MIRRORS AND CABINET BACKSLASHES.

11. MISCELLANEOUS WALL MOUNTED CONTROL DEVICES, SUCH AS SPEAKER VOLUME CONTROLS, DOOR BELLS, AUTOMATIC DOOR PUSH PADS, ETC. SHALL BE MOUNTED AT 46" A.F.F.

12. WALL MOUNTED LIGHTING FIXTURES SHALL BE MOUNTED AS INDICATED ON THE DRAWINGS.

13. PANELBOARDS, NETWORK CABINETS, FIRE ALARM CONTROL CABINETS, AND OTHER SIMILAR CABINETS SHALL BE

MOUNTED 72" A.F.F. TO THE TOP.

14. MOTOR CONTROLLERS AND SAFETY SWITCHES SHALL BE MOUNTED 90" A.F.F.

15. CEILING MOUNTED SMOKE DETECTORS SHALL BE LOCATED NO MORE THAN 30' ON CENTER FROM EACH AND NO MORE THAN 15' FROM THE END OF A CORRIDOR OR SMOKE PARTITION. SMOKE DETECTORS SHALL ALSO NOT BE PLACED WITHIN 3' OF SUPPLY OR RETURN AIR DIFFUSERS, ADJUST SPACING SHOWN ON DRAWINGS AS

REQUIRED.

16. DEVICE BOXES SHALL BE MOUNTED FLUSH IN WALLS UNLESS OTHERWISE NOTED OR REQUIRED. FLUSH SHALL

BE DEFINED AS EVEN WITH THE FACE OF THE WALL, OR RECESSED NO MORE THAN 1/16".

17. WALL BOXES FOR SINGLE AND TWO-GANG SWITCH, CONVENIENCE OUTLET, OR TELECOMMUNICATIONS OR DATA INSTALLATIONS SHALL BE 4" SQUARE WITH APPROPRIATE SINGLE OR DOUBLE GANG PLASTER RINGS OF CORRECT DEPTH FOR WALL CONSTRUCTION. SECTIONAL OR MULTI-GANG BOXES WITH APPROPRIATE PLASTER

RINGS SHALL BE USED FOR MULTI-GANG APPLICATIONS.

18. WHERE DEVICES CONNECTED TO NORMAL AND EMERGENCY POWER SYSTEMS ARE LOCATED IN THE SAME BOX, PROVIDE LISTED METALIC BARRIERS AND SEPARATE RACEWAYS. BOXES SHALL BE PROPERLY CONFIGURED TO

ACCEPT BARRIERS.

1. ALL ELECTRICAL WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE APPLICABLE EDITIONS OF THE 2017 NATIONAL ELECTRICAL CODE, THE STATE BUILDING CODE, AND ANY OTHER LOCAL, STATE, OR FEDERAL CODES, ORDINANCES, OR AUTHORITATIVE INTERPRETATIONS THAT MAY APPLY. A CERTIFICATE OF FINAL ELECTRICAL INSPECTION SHALL BE OBTAINED BY THE CONTRACTOR AT THE COMPLETION OF THE WORK AND

PRESENTED TO BOTH THE OWNER AND THE A/E.

2. THE CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE AND SATISFACTORILY OPERATING SYSTEMS AS INDICATED ON THE CONTRACT DOCUMENTS. IT IS NOTED THAT THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENTS OF SYSTEMS AND WORK. CIRCUIT NUMBERS, INTERCONNECTIONS, HOME RUNS, AND SWITCH LEGS HAVE BEEN SHOWN, AND THE CONTRACTOR SHALL FURNISH AND INSTALL CONDUIT AND WIRING AS REQUIRED TO ACCOMPLISH THE FUNCTIONS INDICATED. SPECIAL SYSTEMS DEVICES (COMMUNICATIONS, SECURITY, ETC.) HAVE BEEN SHOWN AND THE CONTRACTOR SHALL FURNISH AND INSTALL THE REQUIRED QUANTITIES AND TYPES OF CABLES, CONDUCTORS, RACEWAYS, REMOTE POWER SUPPLIES AND CONNECTIONS, SHIELDING REQUIREMENTS, ETC., AS REQUIRED BY THE SYSTEM MANUFACTURER, THE

SPECIFICATIONS, AND ANY APPLICABLE CODES.

3. THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL WORK WITH THE WORK OF ALL OTHER TRADES SO AS TO AVOID CONFLICTS. RESOLVE ALL CONFLICTS THROUGH THE A/E PRIOR TO ROUGH-IN. FAILURE TO PROVIDE SUCH COORDINATION PRIOR TO WORK BEING INSTALLED SHALL NOT BE CAUSE FOR ADDITIONAL COMPENSATION TO THE CONTRACTOR, AND MAY RESULT IN REJECTION OF THE WORK. IT IS THE

CONTRACTORS' RESPONSIBILITY TO COORDINATE SUBSTITUTIONS WITH OTHER TRADES.

4. ALL MATERIALS SHALL BE NEW, SHALL BE SUITABLE FOR THE APPLICATION INTENDED, AND SHALL BEAR LABELS OR MARKINGS INDICATING THIRD PARTY TESTING LABORATORY LISTINGS ACCEPTABLE TO THE AUTHORITY

HAVING JURISDICTION UNLESS OTHERWISE NOTED.

5. VERIFY LOCATIONS OF LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLANS AND THE PLANS OF ALL OTHER TRADES. COORDINATE FIXTURE RECESSING DEPTHS WITH MECHANICAL WORK AND COORDINATE

ACCORDINGLY.

6. ALL WIRING FOR POWER AND LIGHTING SYSTEMS SHALL BE INSTALLED IN METALLIC RACEWAY SYSTEMS UNLESS OTHERWISE NOTED. ALL CONDUCTORS SHALL BE COPPER, SHALL BE # 12AWG MINIMUM, AND SHALL HAVE 600V TYPE THHN/THWN INSULATION, UNLESS OTHERWISE NOTED. ALL RACEWAYS AND CIRCUITS SHALL INCLUDE INSULATED GROUND CONDUCTORS SIZED AS INDICATED OR AS REQUIRED BY THE NEC. MINIMUM

RACEWAY SIZE SHALL BE 3/4" UNLESS OTHERWISE NOTED.

7. RACEWAYS SHALL NOT CONTAIN MORE THAN THREE PHASE CONDUCTORS, THREE NEUTRALS, AND ONE GROUND CONDUCTOR, UNLESS OTHERWISE NOTED. CONTRACTOR SHALL PROVIDE SEPARATE NEUTRALS FOR ALL 20A/1P CIRCUIT BREAKERS. PROVIDING MULTI-POLE CIRCUIT BREAKERS IN CONJUNCTION WITH SHARED NEUTRALS IN A MULTI-WIRE CIRCUIT IN ACCORDANCE WITH 2017 NEC 210.4 SHALL BE APPROVED BY THE

ENGINEER.

8. EXPOSED RACEWAY UP TO 8'-0" ABOVE FINISHED FLOOR OR GRADE ELEVATION, OR ANY RACEWAY SUBJECT TO DAMAGE, SHALL BE RMC. MASS NOTIFICATION PANELS WITH PAGING MICROPHONES SHALL MEET ADA

MOUNTING HEIGHT REQUIREMENTS.

9. ALL CONNECTIONS FOR ELECTRICALLY POWERED EQUIPMENT, INCLUDING BUT NOT LIMITED TO MECHANICAL AND OWNER SUPPLIED EQUIPMENT, SHALL BE FURNISHED AND INSTALLED. WHERE NOT INDICATED AS BEING PROVIDED WITH THE EQUIPMENT, ALL REQUIRED DISCONNECTING MEANS SHALL BE FURNISHED AND INSTALLED AS A PART OF THE ELECTRICAL WORK. COORDINATE LOCATIONS OF DISCONNECTING AND CONTROLLING MEANS WITH EQUIPMENT TO MAINTAIN CODE AND INSTALLATION REQUIREMENTS. DEDICATED WORKING SPACE

FOR MOTOR CONTROLLERS AND SAFETY SWITCHES SHALL BE PER NEC 110.26 REQUIREMENTS.

10. ALL RACEWAY AND WIRING SHALL BE CONCEALED IN FINISHED SPACES, AND MAY BE INSTALLED EXPOSED IN UNFINISHED SPACES SUCH AS MECHANICAL AND ELECTRICAL ROOMS. ALL RACEWAY AND WIRING, WHETHER CONCEALED OR EXPOSED, SHALL BE RUN EITHER PERPENDICULAR OR PARALLEL TO THE BUILDING'S

STRUCTURAL COMPONENTS.

11. PROVIDE PULL AND JUNCTION BOXES AS REQUIRED TO MEET CODE AND INSTALLATION REQUIREMENTS. PULL AND JUNCTION BOXES SHALL BE CONCEALED IN FINISHED SPACES AND LOCATIONS SHALL BE COORDINATED

WITH THE WORK OF ALL OTHER TRADES SO AS TO AVOID CONFLICTS.

12. ALL CONDUCTORS SHALL BE IDENTIFIED AT EACH JUNCTION BOX, OUTLET BOX, CABINET, PULL BOX, ETC., WITH VINYL SELF-ADHESIVE TAGS INDICATING PANEL AND CIRCUIT NUMBER, CONTROL WIRE IDENTIFICATION NUMBER, OR OTHER APPROPRIATE INFORMATION. ALL PULL AND JUNCTION BOXES SHALL BE LABELED AS TO

FUNCTION.

13. ALL EQUIPMENT SHALL BE SECURELY FASTENED BY MEANS OF ANCHORS, RODS, HANGERS, SUPPORTS, GUIDES, SWAY BRACES, ETC., TO MAINTAIN ALIGNMENT AND PREVENT EQUIPMENT MOVEMENT.

14. ALL PENETRATIONS OF FIRE OR SMOKE RATED CONSTRUCTION SHALL BE SEALED WITH FIRESTOPPING MATERIALS APPROVED AND LISTED FOR THE RATING OF THE CONSTRUCTION TO BE PENETRATED. PROVIDE

DOCUMENTATION ON ALL SUCH PENETRATION SEALING SYSTEMS FOR VERIFICATION OF PROPER

INSTALLATION.

15. ALL PENETRATIONS OF ROOFS, EXTERIOR WALLS, FOUNDATIONS, OR OTHER WATER OR MOISTURE PROOF CONSTRUCTION SHALL BE SEALED WITH APPROPRIATE SEALING FITTINGS OR SEALED CONSTRUCTION TO

PREVENT THE INTRODUCTION OF MOISTURE INTO THE BUILDING.

16. WHERE EMPTY RACEWAYS ARE INSTALLED, THEY SHALL BE LABELED AT BOTH ENDS AND FITTED WITH NYLON

PULLSTRINGS FOR FUTURE USE.

17. TO PREVENT PERSONNEL INJURY AND POTENTIAL SYSTEM FAILURE, ELECTRICAL WORK SHALL BE PERFORMED ON DE-ENERGIZED SYSTEMS ONLY. WHERE WORK ON EXISTING SYSTEMS WILL REQUIRE INTERRUPTION OF ELECTRICAL SERVICE, THEN TEMPORARY PROVISIONS ACCEPTABLE TO THE OWNER FOR TEMPORARY POWER SHALL BE UTILIZED UNTIL THE WORK IS COMPLETE. PROVIDE ARC FLASH LABELS FOR ALL SWITCHBOARDS, PANELBOARDS, AND MOTOR CONTROL CENTERS.

18. IF THE CONTRACTOR SUBSTITUTES EQUIPMENT WITH DIFFERENT CHARACTERISTICS THAN WHAT IS SPECIFIED, INCLUDING ELECTRICAL CHARACTERISTICS, IT IS THE CONTRACTOR’S RESPONSIBILITY TO COORDINATE THESE

DIFFERENCES WITH OTHER TRADES.

19. INSTALL CEILING MOUNTED OCCUPANCY SENSORS AT LEAST 6" AWAY FROM AIR DIFFUSERS.

20. IN SPACES WITH WALL-MOUNTED TILE WORK, COORDINATE EXACT LOCATION OF ELECTRICAL ROUGH-IN WITH

PROPOSED TILE PATTERN TO MINIMIZE THE AMOUNT OF TILE CUTTING REQUIRED.

21. RECEPTACLES INSTALLED IN BATHROOMS SHALL BE GROUND FAULT - CIRCUIT INTERRUPTER TYPE.

22. DEVICE BOXES SHALL BE MOUNTED FLUSH IN WALLS UNLESS OTHERWISE NOTED OR REQUIRED. FLUSH SHALL BE DEFINED AS EVEN WITH THE FACE OF THE WALL, OR RECESSED NO MORE THAN 1/16". J-BOXES INSTALLED WITH PLASTER RINGS TO BE FLUSH WITH WALL. EXAMPLE: WALLS WITH 5/8" THICK SHEET ROCK REQUIRES 3/4" PLASTER RING. PROVIDE PLASTER RINGS AS REQUIRED FOR VARYING WALL THICKNESS COVERINGS. J-BOXES

TO BE SUPPORTED WITH STUD-TO-STUD BACK BOX BRACING.

23. WALL BOXES FOR SINGLE AND TWO-GANG SWITCHES, CONVENIENCE OUTLETS, SHALL BE 4" SQUARE.

TELECOMMUNICATION OR DATA WALL BOXES SHALL BE 4-11/16" SQUARE BY 2-1/8" DEEP. WALLS WITH 5/8 THICK SHEET ROCK REQUIRE 3/4" PLASTER RING. PROVIDE SINGLE OR DOUBLE GANG PLASTER RINGS OF CORRECT DEPTH FOR WALL CONSTRUCTION FOR VARYING WALL THICKNESS COVERINGS. J-BOXES TO BE SUPPORTED WITH STUD-TO-STUD BACK BOX BRACING. SECTIONAL OR MULTI-GANG BOXES WITH APPROPRIATE PLASTER

RINGS SHALL BE USED FOR MULTI-GANG APPLICATIONS.

24. WHERE 20A, 120V LIGHTING AND POWER CIRCUIT LENGTHS ARE GREATER THAN 100 FEET AND HAVE A CONNECTED LOAD OF GREATER THAN 8 AMPS, PROVIDE #10 PHASE AND NEUTRAL CONDUCTORS WITH #10 GND

IN MIN. 3/4" CONDUIT.

25. WHERE 20A, 120V LIGHTING AND POWER CIRCUIT LENGTHS ARE GREATER THAN 175 FEET AND HAVE A CONNECTED LOAD OF GREATER THAN 8 AMPS, PROVIDE #8 PHASE AND NEUTRAL CONDUCTORS WITH #8 GND IN

MIN. 3/4" CONDUIT.

26. PROVIDE POWER CONNECTION TO CONTROL PANELS, TRANSFORMERS, AND OTHER ITEMS FURNISHED BY MECHANICAL CONTRACTOR FOR HVAC CONTROL. COORDINATE LOCATIONS OF DEVICES REQUIRING POWER

CONNECTIONS WITH MECHANICAL CONTRACTOR.

27. LABEL OUTLET WALL PLATES WITH CORRESPONDING PANEL AND CIRCUIT NUMBER.

28. ONE-LINE DIAGRAMS ARE MEANT TO SHOW ONLY ELECTRICAL RELATIONSHIPS AND THEREFORE MAY NOT

INCLUDE ALL REQUIRED EQUIPMENT, DEVICES AND ACCESSORIES.

29. ELECTRICAL CONTRACTOR SHALL COORDINATE REQUIREMENTS OF ALL EQUIPMENT PROVIDED BY OTHER

TRADES PRIOR TO ROUGH-IN.

30. DO NOT SCALE DRAWINGS. IF EXACT LOCATION OF EQUIPMENT CANNOT BE DETERMINED CONTACT THE

ARCHITECT/ENGINEER FOR DIRECTION.

31. ALL SIZES ARE BASED ON COPPER CONDUCTORS. SIZES SHALL NOT BE LESS THAN INDICATED.

32. POWER OUTLETS AND J-BOXES ON EMERGENCY POWER SHALL BE RED AND WITH RED COVERPLATES.

33. PROVIDE HOUSE KEEPING PAD FOR ALL FLOOR MOUNTED ELECTRICAL SWITCHGEAR, PANELS, ATS, AND

TRANSFORMERS.

34. ALL RECEPTACLES AND OUTLETS SHALL BE HOSPITAL GRADE.

35. WHERE LIGHTING CONTROLS ARE ADJACENT TO EACH OTHER, PROVIDE COMMON COVERPLATE FOR ALL CONTROLS. PROVIDE BARRIER WHERE NORMAL AND EMERGENCY CIRCUITS ARE IN SAME BACKBOX.

36. PROVIDE BARRIERS WHERE NORMAL AND EMERGENCY CIRCUITS ARE IN COMMON BACKBOX.

37. PROVIDE PULL BOXES FOR FEEDER RUNS PER NEC CODE REQUIREMENTS.

38. PROVIDE A/C GRADE 3/4" TRADE SIZE PLYWOOD BACKBOARD PAINTED WITH TWO COATS OF FIRE RESISTANT BRIGHT HIGH-GLOSS WHITE PAINT IN ALL FOUR WALLS ON TR ROOMS. FOR TR ROOMS WITH TE ENCLOSURES, PROVIDE PLYWOOD BACKBOARD ON THE WALL WITH TE ENCLOSURE.

39. PROVIDE IDENTIFICATION AND LABELING FOR ALL UPS, PDU'S, PANELS, AND POWER STRIPS PER ISTS V4.0

REQUIREMENTS.

H4

H7

A

26-SF 3

26-TU-I-I

DETAIL NUMBER

DRAWING NUMBER WHERE SHOWN

SECTION LETTER

TYPICAL UNIT NO.

BUILDING NO. WHERE EQUIPMENT IS LOCATED.

SUPPLY FAN NO. 3 IN BUILDING NO. 26

EQUIPMENT ABBREVIATION (SUPPLY FAN)

ITEM NUMBER (TERMINAL UNIT NO. 1)

ITEM (TERMINAL UNIT SHOWN)

SERVED BY AIR HANDLER UNIT NO. 1

DRAWING NUMBER WHERE DRAWN

BUILDING NO. WHERE EQUIPMENT IS LOCATED

1. BASIS OF DESIGN FOR ALL ELECTRICAL PANELS, SWITCHGEARS, SWITCHBOARDS, AND TRANSFORMERS IS

SQAURE-D OR APPROVED EQUAL.

2. BASIS OF DESIGN FOR AUTOMATIC TRANSFER SWITCHES IS EATON.

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

G ra p h ic S c a le

/1

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/2

/2

:2

:4

A

M

ELECTRICAL LEGENDS, SCHEDULES AND

ABBREVIATIONS

YW SM

FINAL BID DOCUMENTS 695-21-700EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

E-001

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02Revisions: Date:

REQUIRED LABELS FOR ALL RECEPTACLES:

2" 1/4"

-1

/2

FIRST PART OF LABEL INDICATES RECEPTACLE

INFORMATION SUCH AS RECEPTACLE ID NO,

TYPE, VOLTS, AMPS, PHASE, PANEL BOARD,

CIRCUIT NO, PANEL BOARD ROOM NO.

SECOND PART OF CIRCUIT INDICATES CIRCUIT

INFORMATION SUCH AS IDENTITIY OF

RECEPTACLES ON THE SAME CIRCUIT, PANEL

BOARD, AND CIRCUIT I.D. PROVIDE SECOND LABEL

AS REQUIRED.

ALL LABELS TO BE 1/16" PHENOLIC PLASTIC,

RECEPTACLES ON EMERGENCY POWER TO USE RED

PLASTIC WITH WHITE LETTERING. RECEPTACLES ON

NORMAL POWER TO USE BLACK PLASTIC WITH WHITE

LETTERING TO BE 3/16" HIGH. LOCATION OF LABELS AS

SHOWN OR AS DIRECTED BY COR. SCREW LABELS TO

WALL WITH #6 X3/4" LENGTH SCREW, SET IN PLASTIC

DRYWALL TYPE ANCHORS.

RECEPTACLE

INFO

TYPICAL

RECEPTACLE

CIRCUIT

INFO

CIRCUIT

INFO

PANEL NOMENCLATURE

TYPICAL PANEL DESCRIPTION - OTHER THAN EDH PANELS

E (1) - EMERGENCY SUPPLY; FOR NORMAL SUPPLY "E" IS DROPPED

U (2) - "L" = LIGHTING; "U" = UTILITY; "P" - POWER; "D" - DISTRIBUTION

L (3) - H - 277/480V; L - 120/208V;

CR(4) - LS = LIFE SAFETY; CR = CRITICAL; Q = EQUIPMENT

22(5) - PANEL LOCATION BY FLOOR AND AREA (I.E. LEVEL 02 "A" WING NORTH

1(6) - MULTIPLE PANEL NAME IDENTIFIER

TYPICAL EDH PANEL DESCRIPTION

E (1) - EMERGENCY SUPPLY; FOR NORMAL SUPPLY "E" IS DROPPED

D (2) - "L" = LIGHTING; "U" = UTILITY; "P" - POWER; "D" - DISTRIBUTION

H(3) - H - 277/480V; L - 120/208V;

1(7) - FEEDING SWITCHBOARD NUMBER

2(8) - CIRCUIT FROM FEEDING SWITCHBOARD

LS(4) - LS = LIFE SAFETY; CR = CRITICAL; Q = EQUIPMENT

1(6) - MULTIPLE PANEL NAME IDENTIFIER

NON-EDH PANELS EDH PANELS

E L H

CR

B

IDENTIFIER (1)

IDENTIFIER (2)

IDENTIFIER (3)

IDENTIFIER (4)

IDENTIFIER (5)

IDENTIFIER (6)

E D H L S

IDENTIFIER (1)

IDENTIFIER (2)

IDENTIFIER (3)

IDENTIFIER (7)

IDENTIFIER (5)

IDENTIFIER (6)

IDENTIFIER (8)

EUL-LS-A2-70-1

480 VOLT AND BELOW ELECTRICAL PANEL AND SWITCHBOARD NAMING SCHEME:

SEQUENTIAL NUMBER IF MULTIPLE PANELS WITH SAME ID ON A FLOOR

IDENTIFIES BUILDING PANEL IS LOCATED IN

FLOOR PANEL IS LOCATED ON

IDENTIFIES AREA WHERE PANEL IS LOCATED

TYPE OF EMERGENCY POWER:

- (BLANK) IF NORMAL POWER PANEL

- (LS) FOR LIFE SAFETY BRANCH

- (CR) FOR CRITICAL BRANCH

- (Q) FOR EQUIPMENT BRANCH

- (TR) FOR PANELS IN TELECOM ROOMS

VOLTAGE OF PANEL:

- (H) FOR 277/480 VOLTS

- (L) FOR 120/208 VOLTS

TYPE OF LOAD TYPICALLY FED FROM PANEL:

- (L) FOR LIGHTING

- (U) FOR RECEPTACLES AND NON-LIGHTING LOADS - "UTILITY"

- (D) PANEL FEEDS OTHER PANELS - "DISTRIBUTION"

- (MDP) SERVICE ENTRANCE PANEL OR SWITCHBOARD FOR BUILDING

IDENTIFIES IF PANEL IS ON NORMAL BRANCH OR ESSENTIAL BRANCH

OF ELECTRICAL POWER DISTRIBUTION SYSTEM:

- (BLANK) IF NORMAL POWER PANEL

- (E) FOR ESSENTIAL BRANCH (GENERATOR BACKED UP)

EUL-LS-A2-70-1

EACH PANEL SHALL HAVE THE VA SPECIFICATION REQUIRED LAMINATED LABEL WITH INFORMATION NOTED IN SPECIFICATION. THE ADHESIVE LABEL

AS NOTED BELOW WILL BE INSTALLED BY THE VHA SHOPS.

NEW PANEL NAME - 1/2" LETTERS/NUMBERS

OLD PANEL NAME - 1/8" LETTERS/NUMBERS

RISER DESCRIPTION LISTING ALL PANELS/SWITCHBOARDS/SWITCHGEAR

FROM PANEL TO ELECTRICAL SERVICE ENTRANCE TO BUILDING

(NORMAL POWER PATH ONLY) - 1/8" LETTER/NUMBERS

OLD NAME: "G HALL PANEL"

SOUTH EAST/BUILDING 70E TG0/MDP-70-E #10DL-BEN-70-1 #8UL-2EN-70-4

BASEMENT

LEVEL 1

LEVELS 2-10

RM B0280A

NEW ELECTRICAL ROOM NEW ELECTRICAL SUBSTATION

ATS AND DISTRIBUTION

EQUIPMENT

PHASE 0

SUBSTATION

PHASE 0

LONG LEAD TIME EQUIPMENT,

SUBMIT SHOP DRAWINGS FOR

REVIEW AS EARLY AS POSSIBLE

EXISTING

SERVICE

SWITCHGEAR

B115

FEEDERS - PHASE 0 UNDERGROUND FEEDERS - PHASE 0

NEW TR ROOM

PANELS

PHASE 1

NEW TR ROOM

PANELS

PHASE 1

EXISTING

GENERATOR

SWITCHGEAR

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a le

/1

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/2

/2

:2

:4

A

M

ELECTRICAL LEGENDS, SCHEDULES AND

ABBREVIATIONS

YW SM

FINAL BID DOCUMENTS 695-21-700EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

E-002

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

GENERAL NOTES:

1. MOUNT SUSPENDED FIXTURES AT 9'-0" AFF TO BOTTOM OF FIXTURE, UON. ADJUST FIXTURE LOCATION WITH CABLE TRAYS, RACKS, AND MECHANICAL EQUIPMENT. COORDINATE WITH EQUIPMENT IN ROOM FOR EXACT HANGING LENGTH.

2. PROVIDE NECESSARY ACCESSORIES FOR A COMPLETE INSTALLATION, INCLUDING, BUT NOT LIMITED TO POWER SUPPLIES, OCCUPANCY SENSORS, CONTROLS, LOW VOLTAGE WIRING, MOUNTING BRACKETS, ETC.

3. LIGHTING SYSTEMS IN TR ROOMS SHALL BE CONTROLLED FOR TWO LEVEL LIGHTING PROTOCOL:

LEVEL 1: UNOCCUPIED MODE - SET DIMMERS AT 20% OUTPUT FOR LIGHTING FIXTURES TO ALLOW ENOUGH LIGHT LEVEL FOR CCTV CAMERA TO FUNCTION

LEVEL 2: OCCUPIED MODE - 100% OUTPUT, LIGHTS SHALL BE ALL ON AND PROVIDE MINIMUM 500 LUX IN THE HORIZONTAL PLANE AND 200 LUX IN THE VERTICAL PLANE, MEASURED 3FT ABOVE THE FINISHED FLOOR IN FRONT AND BACK OF CABINETS/RACKS, OR THE MIDDLE OF ALL AISLES BETWEEN CABINETS.

4. LIGHTING FIXTURES WITH BATTERY PACKS SHALL BE PROVIDED WITH TEST SWITCH AND BATTERY PACK.

5. LIGHTING FIXTURES ARE BASIS OF DESIGN, CONTRACTOR CAN SUBMIT AN ALTERNATIVE EQUAL PRODUCT FOR VA APPROVAL.

6. STANDARD DIMMING FOR ALL FIXTURES REQUIRING DIMMING.

ROOMS IN SCOPE - ELECTRICAL

Level Number Name

ELECTRICAL

DEMO REQUIRED

ELECTRICAL

NEW REQUIRED

BUILDING 03

LEVEL 01 1454 TELECOMMUNICATIONS RM. Yes Yes

BUILDING 04

LEVEL 02 2110 TELECOMMUNICATIONS RM Yes Yes

BUILDING 05

LEVEL 01 117 EXISTING TELECOMMUNICATIONS RM. Yes Yes

LEVEL 02 204 TELECOMMUNICATIONS RM. Yes Yes

BUILDING 06

Not Placed D206 STORAGE Yes Yes

LEVEL 01 6-1-C013 STORAGE Yes Yes

LEVEL 01 6-1-D-007 MEN'S TOILET Yes Yes

LEVEL 01 A104 OI&T Yes Yes

LEVEL 01 B103 VACANT OFFICE Yes Yes

LEVEL 02 D203 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 03 C302 TELECOMMUNICATIONS RM. Yes Yes

BUILDING 07

BASEMENT B09 EXISTING TELECOMMUNICATION RM. Yes Yes

BUILDING 20

LEVEL 01 20-1-030 TELECOMMUNICATIONS RM. Yes Yes

BUILDING 43

LEVEL 01 A156 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 02 A201 TELECOMMUNICATIONS RM. Yes Yes

BUILDING 70

LEVEL 01 B-39 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 01 C-17EC TELECOMMUNICATIONS RM. Yes Yes

LEVEL 01 D-125 EXISTING TELECOMMUNICATION RM. Yes Yes

LEVEL 01 E-2B TELECOMMUNICATIONS RM. Yes Yes

BUILDING 97

LEVEL 01 005 TELECOMMUNICATIONS RM. Yes Yes

BUILDING 102

BASEMENT B100FC TELECOMMUNICATIONS RM. Yes Yes

LEVEL 01 100FC EXISTING TELECOMMUNICATION RM. Yes Yes

LEVEL 01 144 TELECOMMUNICATIONS RM. Yes Yes

BUILDING 107

LEVEL 02 200 TELECOMMUNICATIONS RM. Yes Yes

BUILDING 108

LEVEL 02 200 TELECOMMUNICATIONS RM. Yes Yes

BUILDING 109

BASEMENT B001 TELECOMMUNICATIONS RM. Yes Yes

BUILDING 111

BASEMENT B0423 TELECOMMUNICATIONS RM. Yes Yes

BASEMENT B0610E TELECOMMUNICATIONS RM. Yes Yes

BASEMENT B0622 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 01 1180 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 01 1470 DEMARC ROOM Yes Yes

LEVEL 01 1472 ELECTRICAL ROOM Yes Yes

LEVEL 01 1473 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 01 1474J MCR Yes Yes

LEVEL 01 1537B TELECOMMUNICATIONS RM. Yes Yes

LEVEL 02 2235 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 02 2428A TELECOMMUNICATIONS RM. Yes Yes

LEVEL 02 2557 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 03 3308 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 04 4315 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 05 5311 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 06 6410A TELECOMMUNICATIONS RM. Yes Yes

LEVEL 07 7409 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 08 8409 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 09 9409 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 10 10409 TELECOMMUNICATIONS RM. Yes Yes

BUILDING 112

LEVEL 01 108 EXISTING TELECOMMUNICATION RM. Yes Yes

BUILDING 113

BASEMENT 106 REFRIGERATION ROOM Yes Yes

BUILDING 123

LEVEL 01 A107 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 01 B113 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 01 C113 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 01 D113 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 01 E105E TELECOMMUNICATIONS RM. Yes Yes

BUILDING 144

BASEMENT G22 TELEPHONE RM. Yes Yes

BASEMENT G68 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 01 146 TELECOMMUNICATIONS RM. Yes Yes

LEVEL 01 175 TELECOMMUNICATIONS RM. Yes Yes

BUILDING 146

BASEMENT 005 EXISTING TELECOMMUNICATION RM. Yes Yes

BUILDING 147

BASEMENT 002 TELECOMMUNICATIONS RM. Yes Yes

BUILDING 148

BASEMENT 002 TELECOMMUNICATIONS RM. Yes Yes

NTS

RECEPTACLE LABEL DETAIL

NTS

PANEL NOMENCLATURE

LIGHT FIXTURE SCHEDULE

TYPE

MARK

DESCRIPTION MANUFACTURER MODEL LAMP CCT MIN. CRI VOLTAGE WATTS MOUNTING COMMENTS

A 4' LED STRIP LIGHT LITHONIA LIGHTING CLX-L48-5000LM-HEF-RDL-40K-90CRI-HC36 LED 4000K 90 MVOLT 43.9 W SUSPENDED BASIS OF DESIGN

AE 4' LED STRIP LIGHT WITH EMERGENCY POWER PACK LITHONIA LIGHTING CLX-L48-5000LM-HEF-RDL-40K-90CRI-PS1050-HC36 LED 4000K 90 MVOLT 43.9 W SUSPENDED BASIS OF DESIGN

B 2' LED STRIP LIGHT LITHONIA LIGHTING CLX-L24-5000LM-HEF-RD-40K-90CRI-HC36 LED 4000K 90 MVOLT 38.1 W SUSPENDED BASIS OF DESIGN

BE 2' LED STRIP LIGHT WITH EMERGENCY POWER PACK LITHONIA LIGHTING CLX-L24-5000LM-HEF-RDL-40K-90CRI-PS1050-HC36 LED 4000K 90 MVOLT 38.1 W SUSPENDED BASIS OF DESIGN

D 4' LED STRIP LIGHT LITHONIA LIGHTING CLX-L48-5000LM-HEF-RDL-40K-90CRI-HC36 LED 4000K 90 MVOLT 43.9 W SUSPENDED BASIS OF DESIGN

F LED WALLPACK, WITH BATTERY PACK, WET LOCATION LISTED ACUITY LIGHTING FFW1212-NODIM-40W-3800LM-40K-120-EMB125R-WL LED 4000K 90 120V 40.0 W WALL MOUNTED BASIS OF DESIGN

NTS

VA PANEL NAMING CONVENTION DETAIL

NTS

ELECTRICAL PHASING/SEQUENCING PLAN - B111

Revisions: Date:

ELEC. NEW WORK SITE GENERAL NOTES

ELEC. NEW WORK SITE KEYNOTES

NEW MANHOLE PUMP; REFER TO CIVIL

DRAWINGS FOR EXACT LOCATION.

CONNECT TO PANEL MD97 (NEW) IN

BUILDING 97.

NEW MANHOLE PUMP; REFER TO CIVIL

DRAWINGS FOR EXACT LOCATION.

CONNECT TO PANEL MDP-109 (NEW) IN

BUILDING 109.

NEW MANHOLE PUMP; REFER TO CIVIL

DRAWINGS FOR EXACT LOCATION.

CONNECT TO PANEL EQRPAB (EX) IN

BUILDING 144.

NEW MANHOLE PUMP; REFER TO CIVIL

DRAWINGS FOR EXACT LOCATION.

CONNECT TO PANEL B (EX) IN BUILDING 150.

109110

114 113

NRFT45

T105

T106 T107

NEW MANHOLE PUMP; REFER TO CIVIL

DRAWINGS FOR EXACT LOCATION.

CONNECT TO PANEL MDP-5B (NEW) IN

BUILDING 5.

146-E100

146-E100

REFER TO SHEET 146-E100 FOR DEMO

AND NEW WORK RELATED TO NEW

GENERATORS

111-EP100

1. COORDINATE WITH CIVIL FOR EXACT LOCATION AND REQUIREMENTS.

1. PROVIDE NEW 30A/2P, 240V CIRCUIT BREAKER IN EXISTING PANEL AND CONNECT TO THE PUMP

CONTROLLER IN MANHOLE. POWER DISCONNECT SWITCH SHALL BE FURNISHED WITH PUMP

ASSEMBLY. FEEDER SHALL BE MINIMUM (2)#6, #10G, 1" C. PROVIDE LARGER FEEDERS WHERE NEEDED

TO COMPLY WITH VOLTAGE DROP REQUIREMENTS. SEAL WALL PENETRATIONS AS REQUIRED PER

WALL TYPE AND LOCATION. PROVIDE FIRE STOPPING WHERE PASSING RATED WALLS.

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Sprinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

G ra p h ic S c a le

/1

A u to d e s k D o c s /O

C F

M E a s t

M ilw a u k e e E

H R

M

R

C o n s o lid a te d M o d e l (R rv t

/2

/2

:2

:5

A

M

ELECTRICAL SITE PLAN

YW PP

FINAL BID DOCUMENTS 695-21-700EHRM INFRASTRUCTURE

UPGRADES – MILWAUKEE, WI

SEPTEMBER 5, 2025

ES-100

5000 W. NATIONAL AVENUE MILWAUKEE, WI

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

1" = 100'-0"

ELECTRICAL SITE PLAN

STORAGE

ENTRY

ELEC. DEMO GENERAL NOTES

ELEC. DEMO KEYNOTES

STORAGE03-ED101

1. SEE SHEET E-001 FOR GENERAL DEMOLITION NOTES.

2. NOT ALL KEYNOTES ARE USED ON THE SHEET.

3. FULL TONE, DASHED OR HATCHED ITEMS INDICATE TO BE DEMOED. HALF TONE

ITEMS INDICATE TO REMAIN.

MD-3 (EX)

PLAN NORTH

TRUE NORTH

NORTH

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp.

This is the start of the file's text. The full file is on GovTribe.