RFP Attachment 27 - Drawings 695-21-700 Part 20.pdf
PDF 9 MB Posted
- Solicitation number
- 36C77626R0002
About this file
This is a comprehensive set of architectural and engineering drawings for mechanical and electrical demolition and new work at the Clement J Zablocki VA Medical Center in Milwaukee, Wisconsin, as part of RFP 36C77626R0002 Project #695-21-700 EHRM Infrastructure Upgrades Tier 1 Construction. The drawings were prepared by Romanyk Consulting Corp. (Architect/Engineer of Record) and IMEG Corp. (Consultant) and issued as final bid documents on September 5, 2025.
The mechanical drawings detail demolition requirements for reverse osmosis tanks, surge tanks, deaerator tanks, and HVAC systems across multiple buildings (112, 123, and others). The electrical drawings document comprehensive demolition and new work for telecommunications rooms, electrical panels, lighting systems, fire alarm systems, and power distribution infrastructure across numerous buildings on the VA campus (Buildings 3-10, 20, 43, 70, 97, 102, 107-109, 111-113, 123, 144, 146-148). Key electrical work includes removal and replacement of panelboards, installation of new branch circuit panels rated 100A-225A at 120/208V for multiple telecommunications rooms, new receptacles and outlets, lighting fixture replacement with LED fixtures, fire alarm device coordination, and provisions for emergency and critical branch power systems. The drawings specify coordination requirements with mechanical contractors, temporary power provisions during construction, phasing schedules to maintain facility operations, and compliance with 2017 National Electrical Code. Materials are primarily specified as Squared-D or approved equal for panels and switchgear, with Eaton automatic transfer switches. The project requires hospital-grade receptacles, surge protection devices, lightning protection on generator enclosures, and detailed labeling and identification systems for all electrical equipment per VA specifications.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REVERSE OSMOSIS TANK
SURGE TANK
DEAERATOR TANK
UP DN
DN
UP
DN
UP
DN
KEY NOTES #
1. THERE ARE NO MECHANICAL SYSTEMS IN THIS AREA TO BE DEMOLISHED.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
G ra p h ic S c a le
/1
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e E
H R
M
R
C o n s o lid a te d M o d e l (R rv t
/3
/2
:2
:1
A
M
BLDG 112 - FIRST FLOOR OVERALL & ENLARGED
- MECHANICAL DEMOLITION
AGW HWG
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
112-MD101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/8" = 1'-0"
BLDG 112 - FIRST FLOOR - OVERALL MECHANICAL DEMOLITION
1/2" = 1'-0"
BLDG 112 - FIRST FLOOR - ENLARGED MECHANICAL DEMOLITION - ROOM 115
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
IOWA
9/5/25
REVERSE OSMOSIS TANK
SURGE TANK
DEAERATOR TANK
UP DN
DN
UP
DN
UP
DN
KEY NOTES #
112-MH101
112-AC-108
T
112-ACCU-108
REF
1. ROUTE REFRIGERANT PIPE LOW ALONG WALL, THEN OUT AND DOWN EXTERIOR
WALL TO CONDENSING UNIT.
2. TEMPERATURE CONTROLS. REFERENCE MECHANICAL CONTROL PLANS FOR
CONTROLS AND MONITORING.
3. SHADED AREA INDICATES RECOMMENDED 36" CLEARANCE FOR DX UNIT.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
G ra p h ic S c a le
/1
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e E
H R
M
R
C o n s o lid a te d M o d e l (R rv t
/3
/2
:2
:1
A
M
BLDG 112 - FIRST FLOOR OVERALL AND
ENLARGED - MECHANICAL
AGW HWG
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
112-MH101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1/8" = 1'-0"
BLDG 112 - FIRST FLOOR - OVERALL MECHANICAL
1/2" = 1'-0"
BLDG 112 - FIRST FLOOR - ENLARGED PLAN MECHANICAL
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
OV E R H E A D D OO R
L O U V E R WI N D O W
L O U V E R WI N D O W
OV E R H E A D D OO R
L O U V E R WI N D O W
L O U V E R WI N D O W
HALLWAY
MED RM
HALLWAY
MED RM
KEY NOTES #
123-MD101
123-MD101
123-MD101
123-MD101
123-MD101
TELECOMMUNICATIONS RM.
B113
CIO
D113
1. DEMOLISH GRILLE AND DUCT BRANCH. CAP DUCT AT MAIN CONNECTION
OUTSIDE OF ROOM.
0' 15' 30' 60'
Graphic Scale : 1" = 30'-0"
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e E
H R
M
R
C o n s o lid a te d M o d e l (R rv t
/3
/2
:2
:1
A
M
BUILDING 123 LEVEL 01 - MECHANICAL
DEMOLITION PLAN
AGW HWG
FINAL BID DOCUMENTS 695-21-700
EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
123-MD101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
1" = 30'-0"
BUILDING 123 LEVEL 01 FLOOR PLAN - MECHANICAL DEMOLITION
1/4" = 1'-0"
RM. B113 ENLARGED PLAN -
MECHANICAL DEMOLITION
1/4" = 1'-0"
RM. A107 ENLARGED PLAN -
MECHANICAL DEMOLITION
1/4" = 1'-0"
RM. C113 ENLARGED PLAN -
MECHANICAL DEMOLITION
1/4" = 1'-0"
RM. D113 ENLARGED PLAN -
MECHANICAL DEMOLITION
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/4" = 1'-0"
RM. E105E ENLARGED PLAN -
MECHANICAL DEMOLITION
Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
T
T
T
OV E R H E A D D OO R
L O U V E R WI N D O W
L O U V E R WI N D O W
OV E R H E A D D OO R
L O U V E R WI N D O W
L O U V E R WI N D O W
KEY NOTES #
123-AC-A107
A107
TELECOMMUNICATIONS
RM.
123-ACCU-A107
R E
F
REF
REF
B113
TELECOMMUNICATIONS
RM.
123-ACCU-B113 4
123-AC-B113
REF
C113
TELECOMMUNICATIONS
RM.
123-AC-C113
R E
F
REF
123-ACCU-C113
D113
TELECOMMUNICATIONS
RM.
123-ACCU-D113
123-AC-D113
REF
T
E105E
TELECOMMUNICATIONS
RM.
123-AC-E105E
123-ACCU-E105E
REF
T
123-MH101
123-MH101
123-MH101
123-MH101
123-MH101
1. TEMPERATURE CONTROL. REFERENCE MECHANICAL CONTROL PLANS FOR
CONTROLS AND MONITORING.
2. ROUTE REFRIGERANT PIPING ABOVE CEILING AND UP THROUGH ROOF. PROVIDE
SEALED ROOF BOOT AND SEAL EXTERIOR PENETRATIONS WEATHER TIGHT.
3. HATCHED AREA INDICATES MANUFACTURER'S RECOMMENED CLEARANCE FOR
THE EQUIPMENT.
4. MOUNT CONDENSING UNIT ON ROOF ABOVE AT APPROXOMATE LOCATION
SHOW. COORDINATE EXACT LOCATION WITH EXISTING ROOF PENETRATIONS,
ROOF DRAINAGE, AND EQUIPMENT. PROVIDE GUARDRAILS AROUND
CONDENSING UNIT IF WITHIN 10'-0" OF ROOF EDGE.
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e E
H R
M
R
C o n s o lid a te d M o d e l (R rv t
/3
/2
:2
:2
A
M
BUILDING 123 LEVEL 01 - MECHANICAL PLAN
AGW HWG
FINAL BID DOCUMENTS 695-21-700EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
123-MH101
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1/4" = 1'-0"
RM. A107 ENLARGED PLAN - MECHANICAL
1/4" = 1'-0"
RM. B113 ENLARGED PLAN - MECHANICAL
1/4" = 1'-0"
RM. C113 ENLARGED PLAN - MECHANICAL
1/4" = 1'-0"
RM. D113 ENLARGED PLAN - MECHANICAL
1/4" = 1'-0"
RM. E105E ENLARGED PLAN - MECHANICAL
1" = 30'-0"
BUILDING 123 LEVEL 01 FLOOR PLAN - MECHANICAL
Revisions: Date:
PROFESSIONAL ENGINEER
WISCONSIN
ARLO G.
WIECZOREK
#42666-6
SWISHER
ELECTRICAL PHASING NOTES
ELECTRICAL SCOPE OF WORK
ELECTRICAL DEMOLITION NOTESELECTRICAL ABBREVIATIONS
ELECTRICAL LEGEND NOTES
ELECTRICAL GENERAL NOTES
DRAWING SYMBOLS
LIGHTING GENERAL NOTES
LIGHTING SYMBOLS
FIRE ALARM GENERAL NOTES
SCOPE OF WORK
POWER SYMBOLS
FIRE ALARM SYMBOLS
ELECTRICAL EQUIPMENT NOTES
1. ALL LIGHT FIXTURES MAY HAVE AN EQUAL BUT REQUIRE APPROVAL BY ENGINEER AND OWNER. ALL LIGHT FIXTURE PRIOR APPROVALS MUST BE IN WRITING. THE ENGINEER RESERVES THE RIGHT TO REQUIRE “TABLE
TOP” TESTING OF ANY FIXTURE SUBMITTED AS AN EQUAL.
2. ALL RECESSED LIGHTING FIXTURES MUST BE INSTALLED TO PROVIDE A NON-COMBUSTIBLE FIRE RATED
ASSEMBLY.
3. COORDINATE ALL LIGHT FIXTURE MOUNTING REQUIREMENTS WITH REFLECTED CEILING PLAN PRIOR TO
RELEASE OF FIXTURE.
4. ELECTRICAL CONTRACTOR SHALL NOT SHARE NEUTRALS, UNLESS SPECIFICALLY NOTED OTHERWISE. ALL LIGHTING CIRCUITS SHALL HAVE A SEPARATE INSULATED GROUNDING CONDUCTOR INSTALLED WITH EACH
CIRCUIT.
5. ALL LIGHT FIXTURES SHOWN AS HALFTONE ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE.
1' x 4' STRIP LIGHT FIXTURE
1' x 4' STRIP LIGHT FIXTURE WITH EMERGENCY POWER
SWITCH: SINGLE POLE, SINGLE THROW, 120/277 VOLT, 20 AMP
OS OCCUPANCY SENSOR, DUAL TECHNOLOGY, WALL MOUNT
2' X 4' LIGHT FIXTURE WITH EMERGENCY POWER
DOWNLIGHT
DOWNLIGHT WITH EMERGENCY POWER
1. EXISTING FIRE ALARM SYSTEM SHALL STAY OPERATIONAL DURING CONSTRUCTION. PROVIDE NEW OR
TEMPORARY FIRE ALARM DEVICES AS NEEDED PER NFPA AND VA CODE AND REGULATIONS.
2. EXISTING FIRE ALARM SYSTEM IS SIEMENS XLS. NEW FIRE ALARM DEVICES WILL CONNECT TO EXISTING FIRE
ALARM SYSTEM. PROVIDE NEW FIRE ALARM DEVICES TO MATCH EXISTING SYSTEM.
3. EXISTING FIRE ALARM SYSTEM ZONES SHALL BE TESTED PRIOR TO CONNECTING NEW DEVICES. EXPAND
EXISTING FIRE ALARM SYSTEM AS REQUIRED DOE PROPER OPERATION AND FUNCTION.
4. THE EXISTING FIRE ALARM SYSTEM IS A SIMPLEX SYSTEM. THE SERVICE CONTRACTOR IS GRUNAU COMPANY.
CONTACT ERIK KRALOVITZ (PHONE - 414-406-0403). IT IS RECOMMENDED THAT THE EXISTING FIRE SERVICE CONTRACTOR BE INCLUDED AS PART OF THE NEW FIRE ALARM WORK TO RETAIN THE KNOWLEDGE OF THE
SYSTEM.
5. FIRE ALARM DEVICES ARE INDICATED FOR DESIGN INTENT. DEVICE QUANTITIES INDICATED ARE MINIMUM.
PROVIDE ADDITIONAL DEVICES AS REQUIRED IN THE RENOVATION SPACES.
6. IN CONSTRUCTION AREAS REPLACE ALL SMOKE DETECTORS WITH HEAT DETECTORS DURING
CONSTRUCTION. INSTALL NEW SMOKE DETECTORS AT SAME LOCATION OF EXISTING SMOKE DETECTORS
AFTER CONSTRUCTION IN THE AREAS.
2' X 4' LIGHT FIXTURE
NO SCOPE OF WORK ASSOCIATED IN HATCHED AREA, TYPICAL OF ALL ELECTRICAL SHEETS.
RECEPTACLE, DUPLEX
RECEPTACLE, DUPLEX ON EMERGENCY POWER
RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER
RECEPTACLE, DUPLEX WITH DIECAST WEATHERPROOF IN USE COVERPLATE WITH
GROUND FAULT CIRCUIT INTERRUPTER. WATER RESISTANT IN EXTERIOR LOCATIONS
MOUNT 48" AFF.
RECEPTACLE, QUADRAPLEX
RECEPTACLE, QUADRAPLEX ON EMERGENCY POWER
RECEPTACLE, SINGLE
RECEPTACLE, SPECIAL PURPOSE:
REFER TO DRAWING NOTES FOR TYPE
RECEPTACLE, SPECIAL PURPOSE ON EMERGENCY POWER:
REFER TO DRAWING NOTES FOR TYPE
JUNCTION BOX, WALL/CEILING/FLOOR MOUNTED:
SIZE PER N.E.C., REFER TO SPECIFICATIONS FOR GENERAL CONSTRUCTION, SYMBOL
DOES NOT INDICATE ALL JUNCTION BOXES THAT ARE REQUIRED FOR THIS PROJECT
ARE SHOWN ON PLAN(S).
PULL BOX
SWITCHBOARD
PANELBOARD
TRANSFORMER
DISCONNECT SWITCH, UNFUSED
DISCONNECT SWITCH, FUSED
STARTER, COMBINATION WITH DISCONNECT SWITCH
STARTER OR MOTOR CONTROLLER
MOTOR RATED TOGGLE SWITCH WITH OVERCURRENT PROTECTION
MOTOR, SINGLE-PHASE
MOTOR, THREE-PHASE
WYE CONNECTION
EARTH GROUND
T
PB
J J
GFI
J
NOTES:
1. LETTER OR NUMBER DENOTES FIXTURE TYPE, REFER TO LIGHTING FIXTURE SCHEDULE AND LIGHTING PLANS
FOR DETAILS.
2. ALL SYMBOLS SHOWN WITH DASHED LINES DENOTES THAT FIXTURES ARE TO BE REMOVED - THIS APPLIES
ONLY TO DEMOLITION SHEETS.
1. THE EXISTING CAMPUS SUPPORT CENTER (MAIN SERVER ROOM), MAIN TELEPHONE EQUIPMENT ROOM, AND TR ROOMS WILL NEED TO REMAIN OPERATIONAL DURING CONSTRUCTION. EXISTING ELECTRICAL PANELS AND CONNECTIVITY SHALL REMAIN. PROVIDE TEMPORARY ELECTRICAL PANELS AND CIRCUITS WHERE EXISTING ELECTRICAL PANELS WILL BE AFFECTED. COORDINATE WITH VA COR AND SCHEDULES FROM
OTHER TRADES FOR EXACT ELECTRICAL WORK.
2. COORDINATE WITH THE VA FOR ELECTRICAL WORK PHASES. IN GENERAL, LONG LEAD TIME ITEMS, SUCH AS NEW ELECTRICAL SUBSTATION, ELECTRICAL EQUIPMENT SERVING ICC, NEW DISTRIBUTION TYPE EQUIPMENT, AND NEW GENERATOR AND RELATED SITE ELECTRICAL WORK SHALL BE PERFORMED AHEAD OF OTHERS
WORK.
3. NEW ELECTRICAL SUBSTATION IN BUILDING 111 SERVES NEW TR ROOMS, MCR, AND DEMARC ROOMS.
COORDINATE WITH CONSTRUCTION IN MCR AREA FOR POWER EQUIPMENT AND FEEDERS PHASING NEEDS.
4. ELECTRICAL DEMOLITION WORK IN NEW TR SPACES SHALL FOLLOW OTHER DISCIPLINES' WORK SCHEDULES.
5. ELECTRICAL EQUIPMENT SHALL BE DE-ENERGIZED BEFORE WORKING ON THEM. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE VA COR FOR EXISTING ELECTRICAL SYSTEM TIE-INS AND SYSTEM DOWNTIME
NEEDED. PROVIDE SCHEDULE TO VA COR AT LEAST TWO WEEKS PRIOR TO ELECTRICAL WORK.
6. PERFORM ELECTRICAL WORK IN WEEKENDS AND EVENINGS AS NEEDED TO REDUCE INTERRUPTION OF
FACILITY'S NORMAL OPERATION.
1' x 4' STRIP LIGHT FIXTURE
VERTICALLY MOUNTED AT 2'0" AFF
1' x 4' STRIP LIGHT FIXTURE WITH EMERGENCY POWER
VERTICALLY MOUNTED AT 2'0" AFF
1. BUILDING 111 - NEW POWER DISTRIBUTION SYSTEMS FOR 2N POWER FOR THE NEW ICC ROOM AND ALL NEW TR ROOMS. THE 2N UPS SERVES POWER FOR THE ICC, FUTURE SERVER ROOM, AND ALL NEW TR ROOMS.
2. BUILDING 146, 147, AND 148 - DEMOLISH THE EXISTING GENERATORS, NEW OUTDOOR GENERATOR FOR ALL THREE BUILDINGS. EXISTING TRANSFER SWITCHES, UTILITY CONNECTIONS AND SECONDARY DISTRIBUTION
WILL BE REUSED.
3. OTHER BUILDINGS - 2N PANELBOARDS ARE INCLUDED FOR ALL TR ROOMS. EXISTING BUILDING POWER
SYSTEM DISTRIBUTION EQUIPMENT WILL BE MODIFIED TO SERVE THE NEW 2N PANEL.
4. 2N PANELS IN EACH NEW TR ROOM - ONE PANEL WILL BE FED FROM THE GENERATOR POWER DISTRIBUTION, AND THE SECOND PANEL WILL BE FED FROM THE UTILITY POWER DISTRIBUTION.
5. NEW TR ROOMS - WORK INCLUDES NEW WALL OUTLETS, NEW 208V, 3 PHASE OUTLETS FOR RACK UPS POWER, UPS, ZONE POWER SUPPLIES, NEW LED LIGHTING, NEW LIGHTING CONTROLS, POWER CONNECTION
FOR NEW HVAC EQUIPMENT, AND NEW FIRE ALARM DEVICE.
6. ELECTRICAL DEMOLITION IN EXISTING SPACES WHICH WILL BE USED FOR TR ROOMS - WALL OUTLETS, POWER PANELS, AND LIGHTING WILL BE DISCONNECTED AND REMOVED.
7. REMOVE ALL UNUSED CONDUITS IN AND OUT OF THE NEW TR ROOMS.
8. CABLE TRAY AND RACK LOCATIONS SHOWN ON ELECTRICAL SHEETS ARE FOR REFERENCE ONLY. SEE "T"
SERIES SHEETS FOR DETAILS.
9. HVAC EQUIPMENT SHOWN ON ELECTRICAL SHEETS ARE FOR REFERENCE ONLY.
10. ARCHITECTURAL BACKGROUND ON ELECTRICAL SHEETS SHOWING DEMOLITION AND NEW ITEMS ARE FOR
REFERENCE ONLY.
11. ACCESSING TO DATA CLOSETS MUST BE COORDINATED WITH COR TO AVOID IMPACT TO ED, ICU, ORS, AND
MENTAL HEALTH.
12. CONTRACTOR SHALL PLAN FOR AFTER HOURS SHIFT (AFTER 5OM AND BEFORE 5AM) WORK ON 1ST, 2ND, AND LEVEL 03S.
3 SWITCH: THREE WAY, 120/277 VOLT 20 AMP
WP
SD FIRE ALARM SMOKE DETECTOR, CEILING MOUNT
FIRE ALARM HORN/STROBE, WALL MOUNT
FIRE ALARM STROBE, WALL MOUNT
FIRE ALARM RELAY
F
F
2' X 2' LIGHT FIXTURE WITH EMERGENCY POWER
2' X 2' LIGHT FIXTURE
1' x 2' STRIP LIGHT FIXTURE
1' x 2' STRIP LIGHT FIXTURE WITH EMERGENCY POWER
FAR
LED WALL MOUNTED WALLPACK
T
LV LOW VOLTAGE SWITCH
1. ALL ELECTRICAL ITEMS INSTALLED IN WALLS, FLOORS, OR CEILINGS TO BE DEMOLISHED SHALL BE REMOVED IN THEIR ENTIRETY UNLESS OTHERWISE NOTED OR REQUIRED BY OTHER CONDITIONS IN THESE DOCUMENTS. SEE DRAWINGS OF ALL OTHER TRADES FOR EXTENT OF DEMOLITION WORK. ELECTRICAL ITEMS SHALL INCLUDE POWER, LIGHTING, AND SPECIAL SYSTEMS. REFER ALL QUESTIONS OF APPLICABILITY TO THE A/E PRIOR TO BID
FOR CLARIFICATION; OTHERWISE, FIELD DECISIONS BY THE A/E SHALL BE BINDING.
2. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE SCOPE OF THE DEMOLITION WORK AND THAT NOT ALL ITEMS OF ELECTRICAL DEMOLITION ARE NECESSARILY SHOWN. THE CONTRACTOR SHALL BE REQUIRED TO FIELD VERIFY AND FIELD DETERMINE THE SCOPE OF THE DEMOLITION WORK PRIOR TO BID. REFER
ALL QUESTIONS TO THE A/E PRIOR TO BID FOR CLARIFICATION.
3. PHASING OF ELECTRICAL DEMOLITION SHALL FOLLOW THAT OF THE GENERAL CONTRACTOR. COORDINATE REMOVAL OF ELECTRICAL WORK WITH OTHER CONSTRUCTION ACTIVITIES AND THE REQUIREMENTS OF THE
OWNER.
4. THE OWNER SHALL HAVE SALVAGE RIGHTS TO ANY ITEMS THAT ARE TO BE DEMOLISHED. ITEMS SUCH AS SPEAKERS AND CAMERAS AND OTHER ITEMS THAT THE OWNER WISHES TO SALVAGE SHALL BE CAREFULLY REMOVED AND STORED IN A LOCATION AS DIRECTED BY THE OWNER. ALL OTHER ITEMS OF DEMOLITION SHALL
BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE.
5. WHERE DEMOLITION WORK WILL INTERRUPT CIRCUIT CONTINUITY TO OTHER AREAS OF THE FACILITY THAT ARE TO REMAIN IN OPERATION, THEN RACEWAY AND WIRING SHALL BE INSTALLED TO MAINTAIN THOSE AREAS IN COMPLETE OPERATION. PROVIDE TEMPORARY CONNECTIONS AS REQUIRED. CONTRACTOR SHALL SUBMIT A REQUEST FOR ANY INTERRUPTIONS OR OUTAGES TO THE OWNER AT LEAST FIFTEEN (15) WORKING DAYS IN
ADVANCE AND ACCOMMODATE THE OWNER'S NEEDS AS REQUIRED.
6. ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY. CONDUCTORS SHALL BE REMOVED FROM THE ITEM TO BE DEMOLISHED TO THE SOURCE OVERCURRENT DEVICE. RACEWAYS WHICH ARE INSTALLED IN OR BELOW FLOORS OR WITHIN WALLS MAY BE ABANDONED, BUT ALL OVERHEAD OR EXPOSED RACEWAYS SHALL BE REMOVED. EXPOSED RACEWAYS TO BE ABANDONED SHALL BE REMOVED AND SHALL BE CUT OR CHISELED AT LEAST 2"" INTO THE WALL OR FLOOR AND THE OPENING GROUTED SMOOTH.
7. WHERE EXISTING DEVICE OR JUNCTION BOXES MUST REMAIN IN EXISTING WALLS OR CEILINGS (SUCH AS FOR CIRCUITS THAT MUST BE MAINTAINED TO OTHER AREAS), THEN THEY SHALL BE FITTED WITH BLANK
COVERPLATES.
8. WHERE DISTRIBUTION OR BRANCH CIRCUIT EQUIPMENT (PANELBOARDS, SWITCHBOARDS, ETC.) IS TO BE REMOVED, THEN ALL CIRCUITS WHICH FEED ITEMS TO REMAIN SHALL BE RECONNECTED TO NEW DISTRIBUTION
OR BRANCH CIRCUIT EQUIPMENT. REFER ALL QUESTIONS TO THE A/E FOR CLARIFICATION.
9. IF HAZARDOUS MATERIALS (I.E. ASBESTOS, PCB's, ETC.) ARE ENCOUNTERED AT ANY TIME DURING CONSTRUCTION IN THE WORK AREA, STOP WORK IMMEDIATELY AND CONTACT THE A/E OR THE OWNER.
10. REMOVE ALL DEVICES SHOWN ON DEMOLITION PLAN UNLESS OTHERWISE NOTED.
11. REMOVE CABLING BACK TO SOURCE FOR ALL TEL/DATA OUTLETS BEING REMOVED.
12. ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR UPDATING SCHEDULES FOR ANY SWITCHBOARDS AND
PANELBOARDS THAT ARE AFFECTED BY THIS PROJECT AND ARE TO BE TYPEWRITTEN.
13. THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR REQUIRED WORK OUTSIDE THIS PROJECT BOUNDARY NECESSARY TO ENSURE ADJACENT SERVICES REMAIN ENERGIZED DURING CONSTRUCTION OF THE
RENOVATION PROJECT.
14. ALL EXISTING BRANCH CIRCUITS NOT USED ARE TO BE REMOVED BACK TO THE PANEL. THE CIRCUIT BREAKERS ARE TO BE LABELED AS SPARE. EXISTING CONDUITS FROM PANEL ARE TO REMAIN TO ABOVE CEILING.
15. ELECTRICAL CONTRACTOR TO PROVIDE COVERS FOR ANY EXISTING OPEN BUSSING IN PANELBOARDS THAT ARE
AFFECTED BY THIS PROJECT.
16. ELECTRICAL CONTRACTOR TO REMOVE ANY AND ALL UNUSED OR ABANDONED ELECTRICAL EQUIPMENT THAT
RESIDES WITHIN THE AREAS OF THE PROJECT SCOPE.
17. REPAIR OR REPLACE BUILDING ELEMENTS WHICH ARE DAMAGED AS PART OF DEMOLITION WORK.
18. DISCONNECT MECHANICAL EQUIPMENT BEING REMOVED BY MECHANICAL CONTRACTOR. COORDINATE
EQUIPMENT REMOVAL LOCATIONS WITH MECHANICAL DRAWINGS.
19. COORDINATE DEMOLITION WITH THE WORK OF OTHER TRADES.
20. PROVIDE BLANK COVERPLATES FOR ABANDONED RECESSED JUNCTION BOXES.
21. COORDINATE DEMOLITION OF TELECOMMUNICATIONS CABLING WITH OWNER AND GENERAL CONTRACTOR.
22. COORDINATE ANY AND ALL OUTAGES AT LEAST 14 DAYS WITH THE OWNER PRIOR TO ANY DISRUPTION OF
POWER.
23. EXISTING ELECTRICAL SYSTEM IS TO REMAIN IN SERVICE UNLESS OTHERWISE NOTED. ALL CIRCUITS WHICH ARE DISTURBED BY DEMOLITION OR NEW CONSTRUCTION ARE TO BE RECONNECTED AT NO ADDITIONAL COST TO
THE OWNER.
24. REMOVE ALL DEVICES INDICATED BY DARKENED OR DASHED LINES AND ASSOCIATED KEYED NOTES. REMOVE ALL DEVICES IN WALLS AND CEILINGS WHICH ARE SHOWN TO BE DEMOLISHED ON ARCHITECTURAL PLANS, WHETHER OR NOT SUCH DEVICES ARE SHOWN ON THESE PLANS.
25. REMOVE ALL DEVICES, CONDUIT AND CONDUCTORS COMPLETE TO SOURCE ASSOCIATED WITH MECHANICAL EQUIPMENT WHICH IS BEING DEMOLISHED. COORDINATE WITH MECHANICAL PLANS FOR DETAILED INFORMATION.
26. WHERE CIRCUITS ARE REMOVED COMPLETELY, RELABEL EXISTING CIRCUIT BREAKER AS "SPARE".
27. EXISTING LIGHTING AND LIGHTING CONTROLS ARE TO REMAIN UNLESS OTHERWISE NOTED ON THE LIGHTING
PLANS.
1PH SINGLE-PHASE
1P SINGLE POLE
2/C TWO-CONDUCTOR
3/C THREE-CONDUCTOR
3PH THREE-PHASE
4/C FOUR-CONDUCTOR
4W FOUR-WIRE
A/C UNIT AIR CONDITIONING UNIT
AAP ALARM ANNUNCIATOR PANEL
AC ALTERNATING CURRENT OR ARMORED CABLE
ACC ACCESSIBLE
ADDL ADDITIONAL
ADJ ADJACENT, ADJOINING
AF AMPERE FRAME OR AMP FUSE
AFC ABOVE FINISHED COUNTER
AFCI ARC-FAULT CURRENT INTERRUPTER
Ah AMPERE HOUR
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERE INTERRUPTING CAPACITY
ALT ALTERNATE AMP AMPERE
ASC AMPS SHORT CIRCUIT
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
BAT BATTERY
BD BOARD
BFF BELOW FINISH FLOOR
BRKR BREAKER
BYP BY PASS
C CONDUIT
CAB CABINET
CALC CALCULATE
CAP CAPACITY
CAT CATALOG
CATV COMMUNITY ANTENNA TELEVISION
CCR CONTROL CONTACTOR
CCTV CLOSED CIRCUIT TELEVISION
cd CANDELA
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CHW CHILLED WATER
CHWP CHILLED WATER PUMP
CKT CIRCUIT
CKT BRKR CIRCUIT BREAKER OR C/B
CLF CURRENT LIMITING FUSE CLG CEILING
COAX COAX CABLE
COMM COMMUNICATION
COMPT COMPARTMENT
CONC CONCRETE
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CPT CONTROL POWER TRANSFORMER
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CTV CABLE TELEVISION
CU COPPER
CUR CURRENT
DC DIRECT CURRENT
DCP DIMMER CONTROL PANEL
DIAG DIAGRAM
DISC DISCONNECT
DISTR PNL DISTRIBUTION PANEL
DMR SW DIMMER SWITCH
DPDT DOUBLE POLE, DOUBLE THROW
DPST DOUBLE POLE, SINGLE THROW
DRSW DOOR SWITCH DS DISCONNECT SWITCH
E EMERGENCY
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EPO EMERGENCY POWER OFF
EPRF EXPLOSION PROOF
ESC ESCUTCHEON
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EX EXISTINGS
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FIXT FIXTURE
FLA FULL LOAD AMPS
FLUOR FLUORESCENT
FP FIRE PROTECTION
FU SW FUSED SWITCH
FVNR FULL VOLTAGE NON-REVERSING
FVR FULL VOLTAGE REVERSING
G ELECTRICAL GROUND
GEN GENERATOR
GFI GROUND FAULT CIRCUIT INTERRUPTER
H HOSPITAL GRADE
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTOMATIC
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
J-BOX JUNCTION BOX
kV KILOVOLT kVA KILOVOLT AMPERE kVAh KILOVOLT AMPERE PER HOUR kVAR KILOVOLT AMPERE REACTIVE kW KILOWATT kWh KILOWATT HOUR kWhM KILOWATT HOUR METER
LED LIGHT EMITTING DIODE
LPS LOW PRESSURE SODIUM
LRA LOCKED ROTOR AMPS
LT LIGHT
LTG LIGHTING
LTG PNL LIGHTING PANEL
LTNG LIGHTNING
LV LOW V OLTAGE
MC METAL-CLAD
MCA MINIMUM CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MOCP MAXIMUM OVERCURRENT
PROTECTION
MLO MAIN LUGS ONLY
MT MOUNT MTD MOUNTED
MTG MOUNTING
MTS MANUAL TRANSFER SWITCH
MV MEDIUM VOLTAGE
MVA MEGAVOLT-AMPERE
MW MEGAWATT
NC NORMALLY CLOSED
NEUT NEUTRAL (OR N)
NL NIGHT LIGHT
NO NORMALLY OPEN
OL OVERLOAD
P POLE
PB PULL BOX
RCP REFLECTED CEILING PLAN
PEC PHOTOELECTRIC CELL
PED PEDESTAL
PEND PENDANT
PF POWER FACTOR
PH PHASE
PNL PANEL
PT POTENTIAL TRANSFORMER
PTZ PAN, TILT, ZOOM TYPE CAMERA
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
REC RECESSED
RECEP RECEPTACLE
RMS ROOT MEAN SQUARE
SCC SHORT CIRCUIT CAPACITY
SD SMOKE DETECTOR
SPST SINGLE POLE, SINGLE THROW
SURF SURFACE
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
T TAMPER RESISTANT
TEL TELEPHONE
TV TELEVISION
UFD UNDERFLOOR DUCT
UGND UNDERGROUND
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER
SUPPLY
V VOLT
VA VOLT AMPERE
VAR VOLT AMPERE REACTIVE
VFD VARIABLE FREQUENCY DRIVE
VOLT VOLTAGE
W WALL MOUNTEDS
WH WATER HEATER
WP WEATHERPROOF
XFMR TRANSFORMER
1. ALL SYMBOLS INDICATED ARE NOT NECESSARILY USED ON PLANS.
2. ALL MOUNTING DIMENSIONS GIVEN ARE TO THE CENTERLINE (CL) OF THE DEVICE AND ABOVE FINISHED FLOOR
(A.F.F.) OR ABOVE FINISHED GRADE (A.F.G.) UNLESS OTHERWISE NOTED.
3. WALL MOUNTED LIGHT SWITCHES ARE TO BE LOCATED 46" A.F.F. AND 2" FROM EDGE OF DOOR FRAME TO EDGE
OF DEVICE PLATE.
4. OUTLETS INDICATED AS BEING FOR WALL MOUNTED TELEPHONES SHALL BE LOCATED 54" A.F.F. UNLESS
OTHERWISE NOTED.
5. WALL MOUNTED FIRE ALARM MANUAL PULL STATIONS ARE TO BE LOCATED 46" A.F.F. AND WITHIN 72" OF THE
NEAREST ADJACENT EXIT DOOR FROM THE FLOOR OR BUILDING.
6. FIRE ALARM VISUAL NOTIFICATION APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE LENS IS BETWEEN
80" AND 96" A.F.F..
7. CONVENIENCE OUTLETS SHALL BE MOUNTED 18" A.F.F. AND SHALL BE ALIGNED VERTICALLY. PROVIDE HORIZONTAL INSTALLATIONS ONLY WHEN SPACE IS LIMITED, SUCH AS BETWEEN MIRRORS AND CABINET
BACKSPLASHES. THE GROUND PIN SHALL BE ORIENTED IN THE UP POSITION.
8. CONVENIENCE OUTLETS LOCATED IN MECHANICAL AND BOILER ROOMS SHALL BE LOCATED 46" A.F.F.
9. CONVENIENCE OUTLETS LOCATED OUTSIDE SHALL BE GFI AND WEATHERPROOF RATED, FURNISHED WITH A WEATHERPROOF "WHILE-IN- USE" COVER AND MOUNTED 24" A.F.F. OR A.F.G.. EXTERIOR CONVENIENCE OUTLETS SHALL BE INSTALLED WITHIN 25 FEET AND ON THE SAME LEVEL AS HEATING, AIR CONDITIONING AND
REFRIGERATION EQUIPMENT.
10. OUTLETS FOR WALL MOUNTED TELECOMMUNICATIONS OR COMPUTER DEVICES SHALL BE LOCATED 18" A.F.F.
AND SHALL BE ALIGNED VERTICALLY. PROVIDE HORIZONTAL INSTALLATIONS ONLY WHEN SPACE IS LIMITED, SUCH AS BETWEEN MIRRORS AND CABINET BACKSLASHES.
11. MISCELLANEOUS WALL MOUNTED CONTROL DEVICES, SUCH AS SPEAKER VOLUME CONTROLS, DOOR BELLS, AUTOMATIC DOOR PUSH PADS, ETC. SHALL BE MOUNTED AT 46" A.F.F.
12. WALL MOUNTED LIGHTING FIXTURES SHALL BE MOUNTED AS INDICATED ON THE DRAWINGS.
13. PANELBOARDS, NETWORK CABINETS, FIRE ALARM CONTROL CABINETS, AND OTHER SIMILAR CABINETS SHALL BE
MOUNTED 72" A.F.F. TO THE TOP.
14. MOTOR CONTROLLERS AND SAFETY SWITCHES SHALL BE MOUNTED 90" A.F.F.
15. CEILING MOUNTED SMOKE DETECTORS SHALL BE LOCATED NO MORE THAN 30' ON CENTER FROM EACH AND NO MORE THAN 15' FROM THE END OF A CORRIDOR OR SMOKE PARTITION. SMOKE DETECTORS SHALL ALSO NOT BE PLACED WITHIN 3' OF SUPPLY OR RETURN AIR DIFFUSERS, ADJUST SPACING SHOWN ON DRAWINGS AS
REQUIRED.
16. DEVICE BOXES SHALL BE MOUNTED FLUSH IN WALLS UNLESS OTHERWISE NOTED OR REQUIRED. FLUSH SHALL
BE DEFINED AS EVEN WITH THE FACE OF THE WALL, OR RECESSED NO MORE THAN 1/16".
17. WALL BOXES FOR SINGLE AND TWO-GANG SWITCH, CONVENIENCE OUTLET, OR TELECOMMUNICATIONS OR DATA INSTALLATIONS SHALL BE 4" SQUARE WITH APPROPRIATE SINGLE OR DOUBLE GANG PLASTER RINGS OF CORRECT DEPTH FOR WALL CONSTRUCTION. SECTIONAL OR MULTI-GANG BOXES WITH APPROPRIATE PLASTER
RINGS SHALL BE USED FOR MULTI-GANG APPLICATIONS.
18. WHERE DEVICES CONNECTED TO NORMAL AND EMERGENCY POWER SYSTEMS ARE LOCATED IN THE SAME BOX, PROVIDE LISTED METALIC BARRIERS AND SEPARATE RACEWAYS. BOXES SHALL BE PROPERLY CONFIGURED TO
ACCEPT BARRIERS.
1. ALL ELECTRICAL WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE APPLICABLE EDITIONS OF THE 2017 NATIONAL ELECTRICAL CODE, THE STATE BUILDING CODE, AND ANY OTHER LOCAL, STATE, OR FEDERAL CODES, ORDINANCES, OR AUTHORITATIVE INTERPRETATIONS THAT MAY APPLY. A CERTIFICATE OF FINAL ELECTRICAL INSPECTION SHALL BE OBTAINED BY THE CONTRACTOR AT THE COMPLETION OF THE WORK AND
PRESENTED TO BOTH THE OWNER AND THE A/E.
2. THE CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE AND SATISFACTORILY OPERATING SYSTEMS AS INDICATED ON THE CONTRACT DOCUMENTS. IT IS NOTED THAT THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENTS OF SYSTEMS AND WORK. CIRCUIT NUMBERS, INTERCONNECTIONS, HOME RUNS, AND SWITCH LEGS HAVE BEEN SHOWN, AND THE CONTRACTOR SHALL FURNISH AND INSTALL CONDUIT AND WIRING AS REQUIRED TO ACCOMPLISH THE FUNCTIONS INDICATED. SPECIAL SYSTEMS DEVICES (COMMUNICATIONS, SECURITY, ETC.) HAVE BEEN SHOWN AND THE CONTRACTOR SHALL FURNISH AND INSTALL THE REQUIRED QUANTITIES AND TYPES OF CABLES, CONDUCTORS, RACEWAYS, REMOTE POWER SUPPLIES AND CONNECTIONS, SHIELDING REQUIREMENTS, ETC., AS REQUIRED BY THE SYSTEM MANUFACTURER, THE
SPECIFICATIONS, AND ANY APPLICABLE CODES.
3. THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL WORK WITH THE WORK OF ALL OTHER TRADES SO AS TO AVOID CONFLICTS. RESOLVE ALL CONFLICTS THROUGH THE A/E PRIOR TO ROUGH-IN. FAILURE TO PROVIDE SUCH COORDINATION PRIOR TO WORK BEING INSTALLED SHALL NOT BE CAUSE FOR ADDITIONAL COMPENSATION TO THE CONTRACTOR, AND MAY RESULT IN REJECTION OF THE WORK. IT IS THE
CONTRACTORS' RESPONSIBILITY TO COORDINATE SUBSTITUTIONS WITH OTHER TRADES.
4. ALL MATERIALS SHALL BE NEW, SHALL BE SUITABLE FOR THE APPLICATION INTENDED, AND SHALL BEAR LABELS OR MARKINGS INDICATING THIRD PARTY TESTING LABORATORY LISTINGS ACCEPTABLE TO THE AUTHORITY
HAVING JURISDICTION UNLESS OTHERWISE NOTED.
5. VERIFY LOCATIONS OF LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLANS AND THE PLANS OF ALL OTHER TRADES. COORDINATE FIXTURE RECESSING DEPTHS WITH MECHANICAL WORK AND COORDINATE
ACCORDINGLY.
6. ALL WIRING FOR POWER AND LIGHTING SYSTEMS SHALL BE INSTALLED IN METALLIC RACEWAY SYSTEMS UNLESS OTHERWISE NOTED. ALL CONDUCTORS SHALL BE COPPER, SHALL BE # 12AWG MINIMUM, AND SHALL HAVE 600V TYPE THHN/THWN INSULATION, UNLESS OTHERWISE NOTED. ALL RACEWAYS AND CIRCUITS SHALL INCLUDE INSULATED GROUND CONDUCTORS SIZED AS INDICATED OR AS REQUIRED BY THE NEC. MINIMUM
RACEWAY SIZE SHALL BE 3/4" UNLESS OTHERWISE NOTED.
7. RACEWAYS SHALL NOT CONTAIN MORE THAN THREE PHASE CONDUCTORS, THREE NEUTRALS, AND ONE GROUND CONDUCTOR, UNLESS OTHERWISE NOTED. CONTRACTOR SHALL PROVIDE SEPARATE NEUTRALS FOR ALL 20A/1P CIRCUIT BREAKERS. PROVIDING MULTI-POLE CIRCUIT BREAKERS IN CONJUNCTION WITH SHARED NEUTRALS IN A MULTI-WIRE CIRCUIT IN ACCORDANCE WITH 2017 NEC 210.4 SHALL BE APPROVED BY THE
ENGINEER.
8. EXPOSED RACEWAY UP TO 8'-0" ABOVE FINISHED FLOOR OR GRADE ELEVATION, OR ANY RACEWAY SUBJECT TO DAMAGE, SHALL BE RMC. MASS NOTIFICATION PANELS WITH PAGING MICROPHONES SHALL MEET ADA
MOUNTING HEIGHT REQUIREMENTS.
9. ALL CONNECTIONS FOR ELECTRICALLY POWERED EQUIPMENT, INCLUDING BUT NOT LIMITED TO MECHANICAL AND OWNER SUPPLIED EQUIPMENT, SHALL BE FURNISHED AND INSTALLED. WHERE NOT INDICATED AS BEING PROVIDED WITH THE EQUIPMENT, ALL REQUIRED DISCONNECTING MEANS SHALL BE FURNISHED AND INSTALLED AS A PART OF THE ELECTRICAL WORK. COORDINATE LOCATIONS OF DISCONNECTING AND CONTROLLING MEANS WITH EQUIPMENT TO MAINTAIN CODE AND INSTALLATION REQUIREMENTS. DEDICATED WORKING SPACE
FOR MOTOR CONTROLLERS AND SAFETY SWITCHES SHALL BE PER NEC 110.26 REQUIREMENTS.
10. ALL RACEWAY AND WIRING SHALL BE CONCEALED IN FINISHED SPACES, AND MAY BE INSTALLED EXPOSED IN UNFINISHED SPACES SUCH AS MECHANICAL AND ELECTRICAL ROOMS. ALL RACEWAY AND WIRING, WHETHER CONCEALED OR EXPOSED, SHALL BE RUN EITHER PERPENDICULAR OR PARALLEL TO THE BUILDING'S
STRUCTURAL COMPONENTS.
11. PROVIDE PULL AND JUNCTION BOXES AS REQUIRED TO MEET CODE AND INSTALLATION REQUIREMENTS. PULL AND JUNCTION BOXES SHALL BE CONCEALED IN FINISHED SPACES AND LOCATIONS SHALL BE COORDINATED
WITH THE WORK OF ALL OTHER TRADES SO AS TO AVOID CONFLICTS.
12. ALL CONDUCTORS SHALL BE IDENTIFIED AT EACH JUNCTION BOX, OUTLET BOX, CABINET, PULL BOX, ETC., WITH VINYL SELF-ADHESIVE TAGS INDICATING PANEL AND CIRCUIT NUMBER, CONTROL WIRE IDENTIFICATION NUMBER, OR OTHER APPROPRIATE INFORMATION. ALL PULL AND JUNCTION BOXES SHALL BE LABELED AS TO
FUNCTION.
13. ALL EQUIPMENT SHALL BE SECURELY FASTENED BY MEANS OF ANCHORS, RODS, HANGERS, SUPPORTS, GUIDES, SWAY BRACES, ETC., TO MAINTAIN ALIGNMENT AND PREVENT EQUIPMENT MOVEMENT.
14. ALL PENETRATIONS OF FIRE OR SMOKE RATED CONSTRUCTION SHALL BE SEALED WITH FIRESTOPPING MATERIALS APPROVED AND LISTED FOR THE RATING OF THE CONSTRUCTION TO BE PENETRATED. PROVIDE
DOCUMENTATION ON ALL SUCH PENETRATION SEALING SYSTEMS FOR VERIFICATION OF PROPER
INSTALLATION.
15. ALL PENETRATIONS OF ROOFS, EXTERIOR WALLS, FOUNDATIONS, OR OTHER WATER OR MOISTURE PROOF CONSTRUCTION SHALL BE SEALED WITH APPROPRIATE SEALING FITTINGS OR SEALED CONSTRUCTION TO
PREVENT THE INTRODUCTION OF MOISTURE INTO THE BUILDING.
16. WHERE EMPTY RACEWAYS ARE INSTALLED, THEY SHALL BE LABELED AT BOTH ENDS AND FITTED WITH NYLON
PULLSTRINGS FOR FUTURE USE.
17. TO PREVENT PERSONNEL INJURY AND POTENTIAL SYSTEM FAILURE, ELECTRICAL WORK SHALL BE PERFORMED ON DE-ENERGIZED SYSTEMS ONLY. WHERE WORK ON EXISTING SYSTEMS WILL REQUIRE INTERRUPTION OF ELECTRICAL SERVICE, THEN TEMPORARY PROVISIONS ACCEPTABLE TO THE OWNER FOR TEMPORARY POWER SHALL BE UTILIZED UNTIL THE WORK IS COMPLETE. PROVIDE ARC FLASH LABELS FOR ALL SWITCHBOARDS, PANELBOARDS, AND MOTOR CONTROL CENTERS.
18. IF THE CONTRACTOR SUBSTITUTES EQUIPMENT WITH DIFFERENT CHARACTERISTICS THAN WHAT IS SPECIFIED, INCLUDING ELECTRICAL CHARACTERISTICS, IT IS THE CONTRACTOR’S RESPONSIBILITY TO COORDINATE THESE
DIFFERENCES WITH OTHER TRADES.
19. INSTALL CEILING MOUNTED OCCUPANCY SENSORS AT LEAST 6" AWAY FROM AIR DIFFUSERS.
20. IN SPACES WITH WALL-MOUNTED TILE WORK, COORDINATE EXACT LOCATION OF ELECTRICAL ROUGH-IN WITH
PROPOSED TILE PATTERN TO MINIMIZE THE AMOUNT OF TILE CUTTING REQUIRED.
21. RECEPTACLES INSTALLED IN BATHROOMS SHALL BE GROUND FAULT - CIRCUIT INTERRUPTER TYPE.
22. DEVICE BOXES SHALL BE MOUNTED FLUSH IN WALLS UNLESS OTHERWISE NOTED OR REQUIRED. FLUSH SHALL BE DEFINED AS EVEN WITH THE FACE OF THE WALL, OR RECESSED NO MORE THAN 1/16". J-BOXES INSTALLED WITH PLASTER RINGS TO BE FLUSH WITH WALL. EXAMPLE: WALLS WITH 5/8" THICK SHEET ROCK REQUIRES 3/4" PLASTER RING. PROVIDE PLASTER RINGS AS REQUIRED FOR VARYING WALL THICKNESS COVERINGS. J-BOXES
TO BE SUPPORTED WITH STUD-TO-STUD BACK BOX BRACING.
23. WALL BOXES FOR SINGLE AND TWO-GANG SWITCHES, CONVENIENCE OUTLETS, SHALL BE 4" SQUARE.
TELECOMMUNICATION OR DATA WALL BOXES SHALL BE 4-11/16" SQUARE BY 2-1/8" DEEP. WALLS WITH 5/8 THICK SHEET ROCK REQUIRE 3/4" PLASTER RING. PROVIDE SINGLE OR DOUBLE GANG PLASTER RINGS OF CORRECT DEPTH FOR WALL CONSTRUCTION FOR VARYING WALL THICKNESS COVERINGS. J-BOXES TO BE SUPPORTED WITH STUD-TO-STUD BACK BOX BRACING. SECTIONAL OR MULTI-GANG BOXES WITH APPROPRIATE PLASTER
RINGS SHALL BE USED FOR MULTI-GANG APPLICATIONS.
24. WHERE 20A, 120V LIGHTING AND POWER CIRCUIT LENGTHS ARE GREATER THAN 100 FEET AND HAVE A CONNECTED LOAD OF GREATER THAN 8 AMPS, PROVIDE #10 PHASE AND NEUTRAL CONDUCTORS WITH #10 GND
IN MIN. 3/4" CONDUIT.
25. WHERE 20A, 120V LIGHTING AND POWER CIRCUIT LENGTHS ARE GREATER THAN 175 FEET AND HAVE A CONNECTED LOAD OF GREATER THAN 8 AMPS, PROVIDE #8 PHASE AND NEUTRAL CONDUCTORS WITH #8 GND IN
MIN. 3/4" CONDUIT.
26. PROVIDE POWER CONNECTION TO CONTROL PANELS, TRANSFORMERS, AND OTHER ITEMS FURNISHED BY MECHANICAL CONTRACTOR FOR HVAC CONTROL. COORDINATE LOCATIONS OF DEVICES REQUIRING POWER
CONNECTIONS WITH MECHANICAL CONTRACTOR.
27. LABEL OUTLET WALL PLATES WITH CORRESPONDING PANEL AND CIRCUIT NUMBER.
28. ONE-LINE DIAGRAMS ARE MEANT TO SHOW ONLY ELECTRICAL RELATIONSHIPS AND THEREFORE MAY NOT
INCLUDE ALL REQUIRED EQUIPMENT, DEVICES AND ACCESSORIES.
29. ELECTRICAL CONTRACTOR SHALL COORDINATE REQUIREMENTS OF ALL EQUIPMENT PROVIDED BY OTHER
TRADES PRIOR TO ROUGH-IN.
30. DO NOT SCALE DRAWINGS. IF EXACT LOCATION OF EQUIPMENT CANNOT BE DETERMINED CONTACT THE
ARCHITECT/ENGINEER FOR DIRECTION.
31. ALL SIZES ARE BASED ON COPPER CONDUCTORS. SIZES SHALL NOT BE LESS THAN INDICATED.
32. POWER OUTLETS AND J-BOXES ON EMERGENCY POWER SHALL BE RED AND WITH RED COVERPLATES.
33. PROVIDE HOUSE KEEPING PAD FOR ALL FLOOR MOUNTED ELECTRICAL SWITCHGEAR, PANELS, ATS, AND
TRANSFORMERS.
34. ALL RECEPTACLES AND OUTLETS SHALL BE HOSPITAL GRADE.
35. WHERE LIGHTING CONTROLS ARE ADJACENT TO EACH OTHER, PROVIDE COMMON COVERPLATE FOR ALL CONTROLS. PROVIDE BARRIER WHERE NORMAL AND EMERGENCY CIRCUITS ARE IN SAME BACKBOX.
36. PROVIDE BARRIERS WHERE NORMAL AND EMERGENCY CIRCUITS ARE IN COMMON BACKBOX.
37. PROVIDE PULL BOXES FOR FEEDER RUNS PER NEC CODE REQUIREMENTS.
38. PROVIDE A/C GRADE 3/4" TRADE SIZE PLYWOOD BACKBOARD PAINTED WITH TWO COATS OF FIRE RESISTANT BRIGHT HIGH-GLOSS WHITE PAINT IN ALL FOUR WALLS ON TR ROOMS. FOR TR ROOMS WITH TE ENCLOSURES, PROVIDE PLYWOOD BACKBOARD ON THE WALL WITH TE ENCLOSURE.
39. PROVIDE IDENTIFICATION AND LABELING FOR ALL UPS, PDU'S, PANELS, AND POWER STRIPS PER ISTS V4.0
REQUIREMENTS.
H4
H7
A
26-SF 3
26-TU-I-I
DETAIL NUMBER
DRAWING NUMBER WHERE SHOWN
SECTION LETTER
TYPICAL UNIT NO.
BUILDING NO. WHERE EQUIPMENT IS LOCATED.
SUPPLY FAN NO. 3 IN BUILDING NO. 26
EQUIPMENT ABBREVIATION (SUPPLY FAN)
ITEM NUMBER (TERMINAL UNIT NO. 1)
ITEM (TERMINAL UNIT SHOWN)
SERVED BY AIR HANDLER UNIT NO. 1
DRAWING NUMBER WHERE DRAWN
BUILDING NO. WHERE EQUIPMENT IS LOCATED
1. BASIS OF DESIGN FOR ALL ELECTRICAL PANELS, SWITCHGEARS, SWITCHBOARDS, AND TRANSFORMERS IS
SQAURE-D OR APPROVED EQUAL.
2. BASIS OF DESIGN FOR AUTOMATIC TRANSFER SWITCHES IS EATON.
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
G ra p h ic S c a le
/1
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e E
H R
M
R
C o n s o lid a te d M o d e l (R rv t
/2
/2
:2
:4
A
M
ELECTRICAL LEGENDS, SCHEDULES AND
ABBREVIATIONS
YW SM
FINAL BID DOCUMENTS 695-21-700EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
E-001
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02Revisions: Date:
REQUIRED LABELS FOR ALL RECEPTACLES:
2" 1/4"
-1
/2
FIRST PART OF LABEL INDICATES RECEPTACLE
INFORMATION SUCH AS RECEPTACLE ID NO,
TYPE, VOLTS, AMPS, PHASE, PANEL BOARD,
CIRCUIT NO, PANEL BOARD ROOM NO.
SECOND PART OF CIRCUIT INDICATES CIRCUIT
INFORMATION SUCH AS IDENTITIY OF
RECEPTACLES ON THE SAME CIRCUIT, PANEL
BOARD, AND CIRCUIT I.D. PROVIDE SECOND LABEL
AS REQUIRED.
ALL LABELS TO BE 1/16" PHENOLIC PLASTIC,
RECEPTACLES ON EMERGENCY POWER TO USE RED
PLASTIC WITH WHITE LETTERING. RECEPTACLES ON
NORMAL POWER TO USE BLACK PLASTIC WITH WHITE
LETTERING TO BE 3/16" HIGH. LOCATION OF LABELS AS
SHOWN OR AS DIRECTED BY COR. SCREW LABELS TO
WALL WITH #6 X3/4" LENGTH SCREW, SET IN PLASTIC
DRYWALL TYPE ANCHORS.
RECEPTACLE
INFO
TYPICAL
RECEPTACLE
CIRCUIT
INFO
CIRCUIT
INFO
PANEL NOMENCLATURE
TYPICAL PANEL DESCRIPTION - OTHER THAN EDH PANELS
E (1) - EMERGENCY SUPPLY; FOR NORMAL SUPPLY "E" IS DROPPED
U (2) - "L" = LIGHTING; "U" = UTILITY; "P" - POWER; "D" - DISTRIBUTION
L (3) - H - 277/480V; L - 120/208V;
CR(4) - LS = LIFE SAFETY; CR = CRITICAL; Q = EQUIPMENT
22(5) - PANEL LOCATION BY FLOOR AND AREA (I.E. LEVEL 02 "A" WING NORTH
1(6) - MULTIPLE PANEL NAME IDENTIFIER
TYPICAL EDH PANEL DESCRIPTION
E (1) - EMERGENCY SUPPLY; FOR NORMAL SUPPLY "E" IS DROPPED
D (2) - "L" = LIGHTING; "U" = UTILITY; "P" - POWER; "D" - DISTRIBUTION
H(3) - H - 277/480V; L - 120/208V;
1(7) - FEEDING SWITCHBOARD NUMBER
2(8) - CIRCUIT FROM FEEDING SWITCHBOARD
LS(4) - LS = LIFE SAFETY; CR = CRITICAL; Q = EQUIPMENT
1(6) - MULTIPLE PANEL NAME IDENTIFIER
NON-EDH PANELS EDH PANELS
E L H
CR
B
IDENTIFIER (1)
IDENTIFIER (2)
IDENTIFIER (3)
IDENTIFIER (4)
IDENTIFIER (5)
IDENTIFIER (6)
E D H L S
IDENTIFIER (1)
IDENTIFIER (2)
IDENTIFIER (3)
IDENTIFIER (7)
IDENTIFIER (5)
IDENTIFIER (6)
IDENTIFIER (8)
EUL-LS-A2-70-1
480 VOLT AND BELOW ELECTRICAL PANEL AND SWITCHBOARD NAMING SCHEME:
SEQUENTIAL NUMBER IF MULTIPLE PANELS WITH SAME ID ON A FLOOR
IDENTIFIES BUILDING PANEL IS LOCATED IN
FLOOR PANEL IS LOCATED ON
IDENTIFIES AREA WHERE PANEL IS LOCATED
TYPE OF EMERGENCY POWER:
- (BLANK) IF NORMAL POWER PANEL
- (LS) FOR LIFE SAFETY BRANCH
- (CR) FOR CRITICAL BRANCH
- (Q) FOR EQUIPMENT BRANCH
- (TR) FOR PANELS IN TELECOM ROOMS
VOLTAGE OF PANEL:
- (H) FOR 277/480 VOLTS
- (L) FOR 120/208 VOLTS
TYPE OF LOAD TYPICALLY FED FROM PANEL:
- (L) FOR LIGHTING
- (U) FOR RECEPTACLES AND NON-LIGHTING LOADS - "UTILITY"
- (D) PANEL FEEDS OTHER PANELS - "DISTRIBUTION"
- (MDP) SERVICE ENTRANCE PANEL OR SWITCHBOARD FOR BUILDING
IDENTIFIES IF PANEL IS ON NORMAL BRANCH OR ESSENTIAL BRANCH
OF ELECTRICAL POWER DISTRIBUTION SYSTEM:
- (BLANK) IF NORMAL POWER PANEL
- (E) FOR ESSENTIAL BRANCH (GENERATOR BACKED UP)
EUL-LS-A2-70-1
EACH PANEL SHALL HAVE THE VA SPECIFICATION REQUIRED LAMINATED LABEL WITH INFORMATION NOTED IN SPECIFICATION. THE ADHESIVE LABEL
AS NOTED BELOW WILL BE INSTALLED BY THE VHA SHOPS.
NEW PANEL NAME - 1/2" LETTERS/NUMBERS
OLD PANEL NAME - 1/8" LETTERS/NUMBERS
RISER DESCRIPTION LISTING ALL PANELS/SWITCHBOARDS/SWITCHGEAR
FROM PANEL TO ELECTRICAL SERVICE ENTRANCE TO BUILDING
(NORMAL POWER PATH ONLY) - 1/8" LETTER/NUMBERS
OLD NAME: "G HALL PANEL"
SOUTH EAST/BUILDING 70E TG0/MDP-70-E #10DL-BEN-70-1 #8UL-2EN-70-4
BASEMENT
LEVEL 1
LEVELS 2-10
RM B0280A
NEW ELECTRICAL ROOM NEW ELECTRICAL SUBSTATION
ATS AND DISTRIBUTION
EQUIPMENT
PHASE 0
SUBSTATION
PHASE 0
LONG LEAD TIME EQUIPMENT,
SUBMIT SHOP DRAWINGS FOR
REVIEW AS EARLY AS POSSIBLE
EXISTING
SERVICE
SWITCHGEAR
B115
FEEDERS - PHASE 0 UNDERGROUND FEEDERS - PHASE 0
NEW TR ROOM
PANELS
PHASE 1
NEW TR ROOM
PANELS
PHASE 1
EXISTING
GENERATOR
SWITCHGEAR
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e E
H R
M
R
C o n s o lid a te d M o d e l (R rv t
/2
/2
:2
:4
A
M
ELECTRICAL LEGENDS, SCHEDULES AND
ABBREVIATIONS
YW SM
FINAL BID DOCUMENTS 695-21-700EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
E-002
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
GENERAL NOTES:
1. MOUNT SUSPENDED FIXTURES AT 9'-0" AFF TO BOTTOM OF FIXTURE, UON. ADJUST FIXTURE LOCATION WITH CABLE TRAYS, RACKS, AND MECHANICAL EQUIPMENT. COORDINATE WITH EQUIPMENT IN ROOM FOR EXACT HANGING LENGTH.
2. PROVIDE NECESSARY ACCESSORIES FOR A COMPLETE INSTALLATION, INCLUDING, BUT NOT LIMITED TO POWER SUPPLIES, OCCUPANCY SENSORS, CONTROLS, LOW VOLTAGE WIRING, MOUNTING BRACKETS, ETC.
3. LIGHTING SYSTEMS IN TR ROOMS SHALL BE CONTROLLED FOR TWO LEVEL LIGHTING PROTOCOL:
LEVEL 1: UNOCCUPIED MODE - SET DIMMERS AT 20% OUTPUT FOR LIGHTING FIXTURES TO ALLOW ENOUGH LIGHT LEVEL FOR CCTV CAMERA TO FUNCTION
LEVEL 2: OCCUPIED MODE - 100% OUTPUT, LIGHTS SHALL BE ALL ON AND PROVIDE MINIMUM 500 LUX IN THE HORIZONTAL PLANE AND 200 LUX IN THE VERTICAL PLANE, MEASURED 3FT ABOVE THE FINISHED FLOOR IN FRONT AND BACK OF CABINETS/RACKS, OR THE MIDDLE OF ALL AISLES BETWEEN CABINETS.
4. LIGHTING FIXTURES WITH BATTERY PACKS SHALL BE PROVIDED WITH TEST SWITCH AND BATTERY PACK.
5. LIGHTING FIXTURES ARE BASIS OF DESIGN, CONTRACTOR CAN SUBMIT AN ALTERNATIVE EQUAL PRODUCT FOR VA APPROVAL.
6. STANDARD DIMMING FOR ALL FIXTURES REQUIRING DIMMING.
ROOMS IN SCOPE - ELECTRICAL
Level Number Name
ELECTRICAL
DEMO REQUIRED
ELECTRICAL
NEW REQUIRED
BUILDING 03
LEVEL 01 1454 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 04
LEVEL 02 2110 TELECOMMUNICATIONS RM Yes Yes
BUILDING 05
LEVEL 01 117 EXISTING TELECOMMUNICATIONS RM. Yes Yes
LEVEL 02 204 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 06
Not Placed D206 STORAGE Yes Yes
LEVEL 01 6-1-C013 STORAGE Yes Yes
LEVEL 01 6-1-D-007 MEN'S TOILET Yes Yes
LEVEL 01 A104 OI&T Yes Yes
LEVEL 01 B103 VACANT OFFICE Yes Yes
LEVEL 02 D203 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 03 C302 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 07
BASEMENT B09 EXISTING TELECOMMUNICATION RM. Yes Yes
BUILDING 20
LEVEL 01 20-1-030 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 43
LEVEL 01 A156 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 02 A201 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 70
LEVEL 01 B-39 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 C-17EC TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 D-125 EXISTING TELECOMMUNICATION RM. Yes Yes
LEVEL 01 E-2B TELECOMMUNICATIONS RM. Yes Yes
BUILDING 97
LEVEL 01 005 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 102
BASEMENT B100FC TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 100FC EXISTING TELECOMMUNICATION RM. Yes Yes
LEVEL 01 144 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 107
LEVEL 02 200 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 108
LEVEL 02 200 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 109
BASEMENT B001 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 111
BASEMENT B0423 TELECOMMUNICATIONS RM. Yes Yes
BASEMENT B0610E TELECOMMUNICATIONS RM. Yes Yes
BASEMENT B0622 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 1180 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 1470 DEMARC ROOM Yes Yes
LEVEL 01 1472 ELECTRICAL ROOM Yes Yes
LEVEL 01 1473 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 1474J MCR Yes Yes
LEVEL 01 1537B TELECOMMUNICATIONS RM. Yes Yes
LEVEL 02 2235 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 02 2428A TELECOMMUNICATIONS RM. Yes Yes
LEVEL 02 2557 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 03 3308 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 04 4315 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 05 5311 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 06 6410A TELECOMMUNICATIONS RM. Yes Yes
LEVEL 07 7409 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 08 8409 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 09 9409 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 10 10409 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 112
LEVEL 01 108 EXISTING TELECOMMUNICATION RM. Yes Yes
BUILDING 113
BASEMENT 106 REFRIGERATION ROOM Yes Yes
BUILDING 123
LEVEL 01 A107 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 B113 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 C113 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 D113 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 E105E TELECOMMUNICATIONS RM. Yes Yes
BUILDING 144
BASEMENT G22 TELEPHONE RM. Yes Yes
BASEMENT G68 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 146 TELECOMMUNICATIONS RM. Yes Yes
LEVEL 01 175 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 146
BASEMENT 005 EXISTING TELECOMMUNICATION RM. Yes Yes
BUILDING 147
BASEMENT 002 TELECOMMUNICATIONS RM. Yes Yes
BUILDING 148
BASEMENT 002 TELECOMMUNICATIONS RM. Yes Yes
NTS
RECEPTACLE LABEL DETAIL
NTS
PANEL NOMENCLATURE
LIGHT FIXTURE SCHEDULE
TYPE
MARK
DESCRIPTION MANUFACTURER MODEL LAMP CCT MIN. CRI VOLTAGE WATTS MOUNTING COMMENTS
A 4' LED STRIP LIGHT LITHONIA LIGHTING CLX-L48-5000LM-HEF-RDL-40K-90CRI-HC36 LED 4000K 90 MVOLT 43.9 W SUSPENDED BASIS OF DESIGN
AE 4' LED STRIP LIGHT WITH EMERGENCY POWER PACK LITHONIA LIGHTING CLX-L48-5000LM-HEF-RDL-40K-90CRI-PS1050-HC36 LED 4000K 90 MVOLT 43.9 W SUSPENDED BASIS OF DESIGN
B 2' LED STRIP LIGHT LITHONIA LIGHTING CLX-L24-5000LM-HEF-RD-40K-90CRI-HC36 LED 4000K 90 MVOLT 38.1 W SUSPENDED BASIS OF DESIGN
BE 2' LED STRIP LIGHT WITH EMERGENCY POWER PACK LITHONIA LIGHTING CLX-L24-5000LM-HEF-RDL-40K-90CRI-PS1050-HC36 LED 4000K 90 MVOLT 38.1 W SUSPENDED BASIS OF DESIGN
D 4' LED STRIP LIGHT LITHONIA LIGHTING CLX-L48-5000LM-HEF-RDL-40K-90CRI-HC36 LED 4000K 90 MVOLT 43.9 W SUSPENDED BASIS OF DESIGN
F LED WALLPACK, WITH BATTERY PACK, WET LOCATION LISTED ACUITY LIGHTING FFW1212-NODIM-40W-3800LM-40K-120-EMB125R-WL LED 4000K 90 120V 40.0 W WALL MOUNTED BASIS OF DESIGN
NTS
VA PANEL NAMING CONVENTION DETAIL
NTS
ELECTRICAL PHASING/SEQUENCING PLAN - B111
Revisions: Date:
ELEC. NEW WORK SITE GENERAL NOTES
ELEC. NEW WORK SITE KEYNOTES
NEW MANHOLE PUMP; REFER TO CIVIL
DRAWINGS FOR EXACT LOCATION.
CONNECT TO PANEL MD97 (NEW) IN
BUILDING 97.
NEW MANHOLE PUMP; REFER TO CIVIL
DRAWINGS FOR EXACT LOCATION.
CONNECT TO PANEL MDP-109 (NEW) IN
BUILDING 109.
NEW MANHOLE PUMP; REFER TO CIVIL
DRAWINGS FOR EXACT LOCATION.
CONNECT TO PANEL EQRPAB (EX) IN
BUILDING 144.
NEW MANHOLE PUMP; REFER TO CIVIL
DRAWINGS FOR EXACT LOCATION.
CONNECT TO PANEL B (EX) IN BUILDING 150.
109110
114 113
NRFT45
T105
T106 T107
NEW MANHOLE PUMP; REFER TO CIVIL
DRAWINGS FOR EXACT LOCATION.
CONNECT TO PANEL MDP-5B (NEW) IN
BUILDING 5.
146-E100
146-E100
REFER TO SHEET 146-E100 FOR DEMO
AND NEW WORK RELATED TO NEW
GENERATORS
111-EP100
1. COORDINATE WITH CIVIL FOR EXACT LOCATION AND REQUIREMENTS.
1. PROVIDE NEW 30A/2P, 240V CIRCUIT BREAKER IN EXISTING PANEL AND CONNECT TO THE PUMP
CONTROLLER IN MANHOLE. POWER DISCONNECT SWITCH SHALL BE FURNISHED WITH PUMP
ASSEMBLY. FEEDER SHALL BE MINIMUM (2)#6, #10G, 1" C. PROVIDE LARGER FEEDERS WHERE NEEDED
TO COMPLY WITH VOLTAGE DROP REQUIREMENTS. SEAL WALL PENETRATIONS AS REQUIRED PER
WALL TYPE AND LOCATION. PROVIDE FIRE STOPPING WHERE PASSING RATED WALLS.
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
Sprinklered
Office of Construction and Facilities Management
FULLY SPRINKLERED
G ra p h ic S c a le
/1
A u to d e s k D o c s /O
C F
M E a s t
M ilw a u k e e E
H R
M
R
C o n s o lid a te d M o d e l (R rv t
/2
/2
:2
:5
A
M
ELECTRICAL SITE PLAN
YW PP
FINAL BID DOCUMENTS 695-21-700EHRM INFRASTRUCTURE
UPGRADES – MILWAUKEE, WI
SEPTEMBER 5, 2025
ES-100
5000 W. NATIONAL AVENUE MILWAUKEE, WI
15 SUNNEN DR SUITE 104
SAINT LOUIS, MO 63143
314.645.1132 FAX: 314.645.1173
www.imegcorp.com # 17002665.02
1" = 100'-0"
ELECTRICAL SITE PLAN
STORAGE
ENTRY
ELEC. DEMO GENERAL NOTES
ELEC. DEMO KEYNOTES
STORAGE03-ED101
1. SEE SHEET E-001 FOR GENERAL DEMOLITION NOTES.
2. NOT ALL KEYNOTES ARE USED ON THE SHEET.
3. FULL TONE, DASHED OR HATCHED ITEMS INDICATE TO BE DEMOED. HALF TONE
ITEMS INDICATE TO REMAIN.
MD-3 (EX)
PLAN NORTH
TRUE NORTH
NORTH
G ra p h ic S ca le
/2
0"
G ra p h ic S ca le
/3 2"
0"
' G ra p h ic S ca le
/1 6"
0"
' G ra p h ic
S ca le
/8
0"
G ra p h ic S ca le
/4
0"
' G ra p h ic
S ca le
/2
0"
G ra p h ic S ca le
/4
0"
G ra p h ic S ca le
0"
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1
Romanyk Consulting Corp.
This is the start of the file's text. The full file is on GovTribe.