This is an architectural drawing sheet containing plumbing plans for Building 60 repairs at Portsmouth Naval Shipyard in Kittery, Maine. The document is a Department of the Navy Naval Facilities Engineering Systems Command (NAVFAC) technical drawing (Drawing No. P-401) showing enlarged first floor sanitary waste and vent part plans, as well as domestic water supply part plans at a scale of 1/4" = 1'-0". The drawing details piping layouts, fixtures, and equipment locations including water supply lines, drain configurations, vent stacks, water hammer arrestors, and related mechanical systems throughout the building's first floor corridors and adjacent spaces.
The drawing was prepared by the Mid-Atlantic NAVFAC division and is dated October 1, 2025, with Amendment 008 issued on March 10, 2026. Key features shown include multiple 2-inch and 1.5-inch water and vent lines, cleanout locations, floor-mounted water meter installations, quick-connect hose fittings, condensate drain lines from equipment, and coordination notes requiring maintenance of clearance zones around crane rails and bridge crane operational paths. The document includes general notes referencing plumbing legends and abbreviations on Sheet P-001, graphic scales, and keynotes identifying specific pipe sizes, drain configurations, and equipment specifications necessary for proper installation and coordination during construction.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OFFICE
CORRIDOR
STAIR
003A
WOMEN
MEN
CUSTODIAL
p e6 n e4 e3 3.5 n.9 n.5 k.5
WC-1
WC-2
WC-2
L-1
L-1
WC-1
U-1
2" W UP & DN
4" FCO
2" W DN
4" FCO
FD-1
FD-1
WCO
1 1/2" V DN
2" V DN
(TYP 3)
1 1/2" V DN
WCO
2" W DN
2" W DN,
1 1/2" V RISE
4" FCO
2" V DN
4" FCO
3" W DN
3" W&T UP
TO FD-2
4" W DN
1 1/2" V DN
MR-1
3" W DN
S-2
L-1
L-1
CO
W
2"
2"
2" V UP
1 1/2" V RISE
(TYP 2)
1 1/2"
2"
2"
1 1/2"
2"
1 1/2" V RISE
(TYP 2)
1 1/2" V UP
2"
2"
C D
3/4"
4" FCO
4" SAN UP/ DN
3" W
OFFICE
CORRIDOR
STAIR
003A
ANNEX
1 1/2" CW
2" CW
1 1/4"
1" CW
1 1/4"
3/4"
WOMEN
MEN
CUSTODIAL
p e6 n e4 e3 3.5 n.9 n.5 k.5
1 1/2"
DROP
WHA-B
WHA-A
1 1/4"
1 1/4" CW DROP
TPA
1/2" TP DN (TYP 3)
3/4" CW DROP
3/4" HW DROP
3/4" DHWR RISE
3/4" HW UP
3/4" DHWR UP
B4 P-501
S-2
WC-1
WC-2
WC-2
L-1
L-1
WC-1
U-1
MR-1
L-1
L-1
1/2"1/2"1/2"
0.5
0.5
2"
4" W DN 6" R DN
6" R UP2" V UP
INSPECTION
NETWORK
EW-1
(ABOVE)
A3 P-601
S-2 (BELOW)
2" W DN,
1 1/2" V RISE
j g e2 e1
EWH
BFP-1
D4 P-501 1"
IW
ODP
IW5"5"
3/4"
1" CD UP
C D
1"
A4 P-601
1 1/2" V
EWC
INSPECTION
NETWORK
1 1/2" CA DN
2 1/2" CW UP
3" CW DN
W/ BVIV
3/4" CA UP
1 1/2" CA
UP & DROP
WATER
METER
BFP-1
DOMESTIC WATER
ENTRANCE ON
FLOOR MTD STAND
D4 P-501
FLOOR
STANCHEON
3/4" CW
EMV-1
j g e2 e1
EW-1
A3 P-601
EXT-P2
EWH
CA
CA PRESSURE SENSOR
EWC
A3 P-601
A4 P-601
A5 P-601
1/2"
TMV-2
3/4"
A3 P-601 3/4"
1/2"
SATISFACTORY TO DATE
APPROVED
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SHEET
NAVFAC DRAWING NO.
DESIGNER
DRAWN BY
CHECKED BY
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 14 SEP 2023
DESIGN MANAGER
PROJECT MANAGER
FEAD/PM&E
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
P O
R T
S M
O U
T H
N A
V A
L S
H
IP
Y A
R D
K
IT
T
E R
Y M
E
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
ACTIVITY
1740579
T. CARLETON
L. LYONS
S. RUCINSKI
/1
/2
:5
:2
P
M
C U s e rs \m d o n o v a n \D o c u m e n ts \2
.2
B
L D
G
M
E C
H A
N
IC
A L
-V m d o n o v a n
V F
X R
.r v t
P-401
B R
E P
A
IR
S
E N
L A
R G
E D
P L U
M B
IN
G
P A
R T
P L A
N S
MSA
RNC
SRW
K
IT
T E
R Y
M
E P
O R
T S
M O
U T
H N
A V
A L S
H
IP
Y A
R D
R O
IC
C
-M E
P -4
SCALE: 1/4" = 1'-0" (P-104)
C1
ENLARGED FIRST FLOOR SANITARY WASTE AND VENT PART PLAN
SCALE: 1/4" = 1'-0" (P-104)
C3
ENLARGED FIRST FLOOR DOMESTIC WATER SUPPLY PART PLAN
1/4" = 1' - 0" 0 5' 10' 15'1'
GENERAL NOTES
GRAPHIC SCALE
KEY PLAN
KEYNOTES
1.
2.
SEE P-001 FOR PLUMBING LEGENDS, ABBREVIATIONS AND GENERAL
NOTES.
COORDINATE THE INSTALLATION OF PIPING AND EQUIPMENT TO
MAINTAIN MANDATORY CLEARANCE ZONES AROUND CRANE RAILS AND
BRIDGE CRANE OPERATIONAL TRAVEL PATH.
MATCH LINE
CHECK GRAPHIC SCALE BEFORE USING
PLAN
NORTH
1 PIPE 3/4" DRAIN DOWN TO SINK S-2. SECURE TO WALL.
2" INDIRECT WASTE DRAIN TRAP WITH AIR GAP FITTING. PIPE DRAIN
FROM BFP-1 AND CONDENSATE DRAINS FROM BCU-1 AND IU-2 TO AIR
GAP FITTING.
PROVIDE 1/2" CA WITH ISOLATION BALL VALVE AND QUICK CONNECT
FEMALE HOSE CONNECTION FITTING 80" AFF. COORDINATE QUICK
CONNECT FITTING SELECTION WITH CONTRACTING OFFICER.
PROVIDE 8"X8" WALL MOUNTED WATER HAMMER ARRESTOR SERVICE
ACCESS DOOR.
C1 P-401
C3 P-401
SCALE: 1/4" = 1'-0" (P-104)
A1
ENLARGED FIRST FLOOR SANITARY WASTE AND VENT PART PLAN
SCALE: 1/4" = 1'-0" (P-104)
A3
ENLARGED FIRST FLOOR DOMESTIC WATER SUPPLY PART PLAN
A1 P-401
A3 P-401
(THIS SHEET ONLY)
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
F
IN
A L
S U
B M
IS
S
IO
N
/0
1/
R
S H
A
M E
N D
M E
N T
/1
0/
R
S H
| Sheets |
| P-401 - ENLARGED PLUMBING PART PLANS 1 |
File details come from the government source that posted it. Updated .