SECTION 08 51 13 - ALUMINUM WINDOWS TECHNICAL SPECIFICATION

This is a technical specification document for aluminum windows at Tinker Air Force Base, Oklahoma, issued in April 2019. The specification establishes comprehensive requirements for prime aluminum window units, including design standards, performance criteria, fabrication methods, and installation procedures. Windows must comply with AAMA/WDMA/CSA 101/I.S.2/A440 standards and meet antiterrorism performance requirements through computational design analysis, dynamic analysis, or standard airblast testing per ASTM F1642. Key performance requirements include a minimum wind-loading design pressure of 30 psf, air infiltration and water penetration limits per AAMA standards, and thermal performance specifications with U-factors not exceeding 0.46 Btu/hr-ft²-F for non-residential windows and 0.35 Btu/hr-ft²-F for residential Energy Star-qualified windows. Window manufacturers must demonstrate 10 years of documented successful experience and provide warranties extending beyond one year.

The specification covers two primary window types: single-hung windows (Type H-LC25) and fixed windows (Type F-LC25), with options for forced-entry resistant variants. Fabrication requirements mandate aluminum alloy 6063-T6 construction with anodic Class I coatings (0.7 mil minimum), thermal breaks for thermal-barrier windows, weatherstripping conforming to AAMA 701/702, and a minimum condensation resistance factor of 60. Installation must follow manufacturer instructions, with proper anchoring to supporting structures (minimum three anchors per jamb), dissimilar material protection, and post-installation cleaning. Comprehensive submittals requiring government approval include shop drawings, product data, design analysis calculations, test reports, and operation and maintenance documentation. Window cleaners' bolts are required for all windows 7 feet or higher above finished grade, utilizing AISI Series 300 corrosion-resistant steel double-head bolts per IWCA I-14.1 standards.

View the file

Other files

File Type Posted
03 11 13.00 10.pdf PDF
03 20 00.00 10.pdf PDF
03 30 00.pdf PDF
07 14 00.pdf PDF
07 19 00.pdf PDF
07 21 16.pdf PDF
07 22 00.pdf PDF
07 31 13.pdf PDF
07 52 00.pdf PDF
07 72 20.pdf PDF
08 34 01.pdf PDF
08 34 19.10 20.pdf PDF
08 52 00.pdf PDF
09 29 00.pdf PDF
10 21 13.pdf PDF
10 22 13.pdf PDF
13 34 19.pdf PDF
21 13 13.pdf PDF
23 03 00.pdf PDF
23 05 48.00 40.pdf PDF
23 07 00.pdf PDF
23 09 23.01.pdf PDF
23 34 23.00 40.pdf PDF
23 52 00.pdf PDF
23 65 00.pdf PDF
23 70 03.pdf PDF
26 00 00.00 20.pdf PDF
26 05 48.00 10.pdf PDF
26 29 23.pdf PDF
26 32 14.00 10.pdf PDF
31 23 15.pdf PDF
31 23 16.pdf PDF
32 01 13.pdf PDF
32 11 11.pdf PDF
32 11 29.pdf PDF
32 12 10.1.pdf PDF
32 12 10.2.pdf PDF
32 13 14.pdf PDF
190023 Renovate Restrooms B117 RFIs_FINAL_COR_Signed.pdf PDF
TAFB_Tech_Reqs (Div 02-48).zip ZIP file
Model.zip ZIP file
000_TABLE OF CONTENTS.pdf PDF
01 32 16.00 20.pdf PDF
01 33 16.00 10.pdf PDF
01 42 00.pdf PDF
01 78 00.pdf PDF
Tinker General Requirements Specifications_Nov 2022_Change Log.pdf PDF
Initial Site Visit WWYK190023.pdf PDF
Att12_190023_Drawings_Final.pdf PDF
Section L - Instructions to Offerors.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Ti nker AFB, OK TAFB Techni cal Spr ci f i cat i ons 2019

SECTI ON 08 51 13

ALUMI NUM WI NDOWS

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.

ALUMI NUM ASSOCI ATI ON ( AA)

AA DAF45 ( 2003; Reaf f i r med 2009) Desi gnat i on Syst em f or Al umi num Fi ni shes

AMERI CAN ARCHI TECTURAL MANUFACTURERS ASSOCI ATI ON ( AAMA)

AAMA 1302. 5 ( 1976) Vol unt ar y Speci f i cat i ons f or For ced- Ent r y Resi st ant Al umi num Pr i me Windows

AAMA 1503 ( 2009) Vol unt ar y Test Met hod f or Ther mal Tr ansmi t t ance and Condensat i on Resi st ance of Wi ndows, Door s and Gl azed Wal l Sect i ons

AAMA 2603 ( 2015) Vol unt ar y Speci f i cat i on, Per f or mance Requi r ement s and Test Pr ocedur es f or Pi gment ed Or gani c Coat i ngs on Al umi num Ext r usi ons and Panel s

AAMA 2604 ( 2013) Vol unt ar y Speci f i cat i on, Per f or mance Requi r ement s and Test Pr ocedur es f or Hi gh Per f or mance Or gani c Coat i ngs on Al umi num Ext r usi ons and Panel s

AAMA 2605 ( 2013) Vol unt ar y Speci f i cat i on, Per f or mance Requi r ement s and Test Pr ocedur es f or Super i or Per f or mi ng Or gani c Coat i ngs on Al umi num Ext r usi ons and Panel s

AAMA 611 ( 2014) Vol unt ar y Speci f i cat i on f or Anodi zed Ar chi t ect ur al Al umi num

AAMA 701/ 702 ( 2011) Vol unt ar y Speci f i cat i on f or Pi l e Weat her st r i ppi ng and Repl aceabl e Fenest r at i on Weat her seal s

AAMA 902 ( 2014) Vol unt ar y Speci f i cat i on f or Sash Balances

AAMA WSG. 1 ( 1995) Wi ndow Sel ect i on Gui de

AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 ( 2011; Updat e 1 2014) Nor t h Amer i can Fenest r at i on St andar d/ Speci f i cat i on f or Wi ndows, Door s, and Skyl i ght s

Apr i l 2019 Page 1 SECTI ON 08 51 13

ASTM I NTERNATI ONAL ( ASTM)

ASTM A276/ A276M ( 2016a) St andar d Speci f i cat i on f or St ai nl ess St eel Bar s and Shapes

ASTM E1300 ( 2016) St andar d Pr act i ce f or Det er mi ni ng Load Resi st ance of Gl ass i n Bui l di ngs

ASTM F1642 ( 2012) St andar d Test Met hod f or Gl azi ng and Gl azi ng Syst ems Subj ect t o Ai r bl ast Loadings

ASTM F2248 ( 2012) St andar d Pr act i ce f or Speci f y i ng an Equi val ent 3- Second Dur at i on Desi gn Loadi ng f or Bl ast Resi st ant Gl azi ng Fabr i cat ed wi t h Lami nat ed Gl ass

I NTERNATI ONAL WI NDOW CLEANI NG ASSOCI ATI ON ( I WCA)

I WCA I - 14. 1 ( 2001) Wi ndow Cl eani ng Saf et y St andar d

NATI ONAL FENESTRATI ON RATI NG COUNCI L ( NFRC)

NFRC 100 ( 2014) Pr ocedur e f or Det er mi ni ng Fenest r at i on Pr oduct U- Fact or s

NFRC 200 ( 2014) Pr ocedur e f or Det er mi ni ng Fenest r at i on Pr oduct Sol ar Heat Gai n Coef f i c i ent and Vi s i bl e Tr ansmi t t ance at Nor mal I nci dence

NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)

NFPA 101 ( 2015; ERTA 2015) Li f e Saf et y Code

1. 2 CERTIFICATION

Each pr i me wi ndow uni t must bear t he AAMA Label war r ant i ng t hat t he pr oduct compl i es wi t h AAMA/ WDMA/ CSA 101/ I . S. 2/ A440. Cer t i f i ed t est r epor t s at t est i ng t hat t he pr i me wi ndow uni t s meet t he r equi r ement s of AAMA/ WDMA/ CSA 101/ I . S. 2/ A440, i ncl udi ng t est s i ze, wi l l be accept abl e i n l i eu of pr oduct l abel i ng.

1. 3 SUBMITTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;

submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00

SUBMI TTAL PROCEDURES:

SD- 02 Shop Dr awi ngs

Wi ndows; G

Fabr i cat i on Dr awi ngs

SD- 03 Pr oduct Dat a

Apr i l 2019 Page 2 SECTI ON 08 51 13

Wi ndows; G

Har dwar e; G

Fast ener s; G

Wi ndow Per f or mance; G

Ther mal - Bar r i er Wi ndows; G

Mul l i ons; G

Wi ndow Cl eaner s ' Bol t s; G

Scr eens; G

Weat her st r i ppi ng; G

Accessor i es; G

Adhesives

Ther mal Per f or mance; G

SD- 04 Sampl es

Fi ni sh Sampl e

Wi ndow Sampl e

SD- 05 Desi gn Dat a

St r uct ur al Cal cul at i ons f or Def l ect i on; G

Desi gn Anal ysi s; G

Submi t desi gn anal ysi s wi t h cal cul at i ons showi ng t hat t he desi gn of each di f f er ent s i ze and t ype of al umi num wi ndow uni t and i t s anchor age t o t he st r uct ur e meet s t he mi ni mum ant i t er r or i sm st andar ds r equi r ed by par agr aph " Mi ni mum Ant i t er r or i sm Per f or mance" , unl ess conf or mance i s demonst r at ed by St andar d Ai r bl ast Test r esul t s. Cal cul at i ons ver i f y i ng t he st r uct ur al per f or mance of each wi ndow pr oposed f or use, under t he gi ven l oads, must be pr epar ed and si gned by a r egi st er ed Pr of essi onal Engi neer . The wi ndow component s and anchor age devi ces t o t he st r uct ur e, as det er mi ned by t he desi gn anal ysi s, must be r ef l ect ed i n t he shop dr awi ngs.

SD- 06 Test Repor t s

Mi ni mum Condensat i on Resi st ance Fact or

Resi st ance t o For ced Ent r y

St andar d Ai r bl ast Test ; G

For Mi ni mum Ant i t er r or i sm wi ndows, i n l i eu of a Desi gn Anal ysi s, r esul t s of ai r bl ast t est i ng, whet her by ar ena t est or shockt ube, Apr i l 2019 Page 3 SECTI ON 08 51 13 must be i ncl uded i n a t est r epor t , pr ovi di ng i nf or mat i on i n accor dance wi t h ASTM F1642, as pr epar ed by t he i ndependent t est i ng agency per f or mi ng t he t est . The t est r esul t s must demonst r at e t he abi l i t y of each wi ndow pr oposed f or use t o wi t hst and t he ai r bl ast l oadi ng par amet er s and achi eve t he hazar d l evel r at i ng speci f i ed i n par agr aph " St andar d Ai r bl ast Test Met hod" .

SD- 10 Oper at i on and Mai nt enance Dat a

Wi ndows, Dat a Package 1; G

Submi t i n accor dance wi t h Sect i on 01 78 23 OPERATI ON AND

MAI NTENANCE DATA.

Pl ast i c I dent i f i cat i on

When not l abel ed, i dent i f y t ypes i n Oper at i on and Mai nt enance Manual.

1. 4 QUALI TY ASSURANCE

1. 4. 1 Shop Dr awi ng Requi r ement s

Pr ovi de dr awi ngs t hat i ndi cat e el evat i ons of wi ndows, f ul l - s i ze sect i ons, t hi ckness and gages of met al , f ast eni ngs, pr oposed met hod of anchor i ng, s i ze and spaci ng of anchor s, det ai l s of const r uct i on, met hod of gl azi ng, det ai l s of oper at i ng har dwar e, mul l i on det ai l s, met hod and mat er i al s f or weat her st r i ppi ng, met hod of at t achi ng scr eens, mat er i al and met hod of at t achi ng subf r ames, st ool s, casi ngs, s i l l s , t r i m, i nst al l at i on det ai l s, and ot her r el at ed i t ems.

1. 4. 2 Sampl e Requi r ement s

1. 4. 2. 1 Fi ni sh Sampl e Requi r ement s

Submi t col or char t of st andar d f act or y col or coat i ngs when f act or y- f i ni sh col or coat i ng i s t o be pr ovi ded.

1. 4. 2. 2 Wi ndow Sampl e Requi r ement s

Submi t one f ul l - s i ze cor ner of each wi ndow t ype pr oposed f or use. Wher e scr eens or weat her st r i ppi ng i s r equi r ed, f i t sampl e wi t h such i t ems t hat ar e t o be used.

1. 4. 3 Desi gn Dat a Requi r ement s

Submi t cal cul at i ons t o subst ant i at e compl i ance wi t h def l ect i on r equi r ement s and Mi ni mum Ant i t er r or i sm Per f or mance cr i t er i a. A r egi st er ed Pr of essi onal Engi neer must pr ovi de cal cul at i ons.

Submi t desi gn anal ysi s wi t h cal cul at i ons showi ng t hat t he desi gn of each di f f er ent s i ze and t ype of al umi num wi ndow uni t and i t s anchor age t o t he st r uct ur e meet s t he r equi r ement s of par agr aph " Mi ni mum Ant i t er r or i sm Per f or mance Cr i t er i a" . Cal cul at i ons ver i f y i ng t he st r uct ur al per f or mance of each wi ndow pr oposed f or use, under t he gi ven l oads, must be pr epar ed and si gned by a r egi st er ed pr of essi onal engi neer . Ref l ect t he wi ndow component s and anchor age devi ces t o t he st r uct ur e, as det er mi ned by t he

Apr i l 2019 Page 4 SECTI ON 08 51 13 desi gn anal ysi s, i n t he shop dr awi ngs.

1. 4. 4 Test Repor t Requi r ement s

Submi t t est r epor t s f or each t ype of wi ndow at t est i ng t hat i dent i cal wi ndows have been t est ed and meet t he r equi r ement s speci f i ed her ei n f or conf or mance t o AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 i ncl udi ng t est s i ze, and mi ni mum condensat i on r esi st ance f act or ( CRF) , and r esi st ance t o f or ced ent r y, and, f or Mi ni mum Ant i t er r or i sm wi ndows, i n l i eu of a Desi gn Anal ysi s, r esul t s of a St andar d Ai r bl ast Test .

1. 5 DELI VERY AND STORAGE

Del i ver wi ndows t o pr oj ect s i t e i n an undamaged condi t i on. Use car e i n handl i ng and hoi st i ng wi ndows dur i ng t r anspor t at i on and at t he j obsi t e.

St or e wi ndows and component s out of cont act wi t h t he gr ound, under a weat her t i ght cover i ng, so as t o pr event bendi ng, war pi ng, or ot her wi se damagi ng t he wi ndows. Repai r damaged wi ndows t o an " as new" condi t i on as appr oved. I f wi ndows can not be r epai r ed, pr ovi de a new uni t .

1. 6 PROTECTION

Pr ot ect f i ni shed sur f aces dur i ng shi ppi ng and handl i ng usi ng t he manuf act ur er ' s st andar d met hod. Do not appl y coat i ngs or l acquer s t o sur f aces t o whi ch caul k i ng and gl azi ng compounds must adher e.

1. 7 PLASTI C I DENTI FI CATI ON

Label pl ast i c pr oduct s pr ovi ded t o i ndi cat e t hei r pol ymer i c composi t i on accor di ng t o t he f ol l owi ng l i s t . Wher e pr oduct s ar e not l abel ed, pr ovi de pr oduct dat a i ndi cat i ng pol ymer i c i nf or mat i on i n Oper at i on and Mai nt enance Manual.

a. Type 1: Pol yet hyl ene Ter epht hal at e ( PET, PETE) .

b. Type 2: Hi gh Densi t y Pol yet hyl ene ( HDPE) .

c. Type 3: Vi nyl ( Pol yvi nyl Chl or i de or PVC) .

d. Type 4: Low Densi t y Pol yet hyl ene ( LDPE) .

e. Type 5: Pol ypr opyl ene ( PP) .

f . Type 6: Pol yst yr ene ( PS) .

g. Type 7: Ot her . Use of t hi s code i ndi cat es t hat t he package i n quest i on i s made wi t h a r esi n ot her t han t he si x l i s t ed above, or i s made of mor e t han one r esi n l i s t ed above, and used i n a mul t i - l ayer combination.

1. 8 FI ELD MEASUREMENTS

Take f i el d measur ement s pr i or t o pr epar at i on of t he dr awi ngs and fabrication.

Apr i l 2019 Page 5 SECTI ON 08 51 13

1. 9 PERFORMANCE REQUI REMENTS

1. 9. 1 Wi nd Loadi ng Desi gn Pr essur e

Desi gn wi ndow component s, i ncl udi ng mul l i ons, har dwar e, and anchor s, t o wi t hst and a wi nd- l oadi ng desi gn pr essur e of at l east 30 pounds per squar e f oot ( psf ) .

1. 10 DRAWINGS

Submi t t he Fabr i cat i on Dr awi ngs f or al umi num wi ndow uni t s showi ng compl et e wi ndow assembl y i ncl udi ng har dwar e, weat her st r i ppi ng, and subf r ame assembl y det ai l s.

1. 11 WI NDOW PERFORMANCE

Al umi num wi ndows must meet t he f ol l owi ng per f or mance r equi r ement s.

Per f or m t est i ng r equi r ement s by an i ndependent t est i ng l abor at or y or agency.

1. 11. 1 St r uct ur al Per f or mance

St r uct ur al t est pr essur es on wi ndow uni t s must be f or posi t i ve l oad ( i nwar d) and negat i ve l oad ( out war d) . Af t er t est i ng, t her e wi l l be no gl ass br eakage, per manent damage t o f ast ener s, har dwar e par t s, suppor t ar ms or act uat i ng mechani sms or any ot her damage whi ch coul d cause wi ndow t o be i noper abl e. Ther e must be no per manent def or mat i on of any mai n f r ame, sash or vent i l at or member i n excess of t he r equi r ement s est abl i shed by AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 f or t he wi ndow t ypes and cl assi f i cat i on speci f i ed i n t hi s sect i on.

1. 11. 2 Mi ni mum Ant i t er r or i sm Per f or mance

Wi ndows must meet t he mi ni mum ant i t er r or i sm per f or mance as speci f i ed i n t he par agr aphs bel ow. Conf or mance t o t he per f or mance r equi r ement s must be val i dat ed by one of t he f ol l owi ng met hods.

1. 11. 2. 1 Comput at i onal Desi gn Anal ysi s Met hod

Wi ndow f r ames, mul l i ons, and sashes must be desi gned t o t he cr i t er i a l i s t ed her ei n. Comput at i onal desi gn anal ysi s must i ncl ude cal cul at i ons ver i f y i ng t he st r uct ur al per f or mance of each wi ndow pr oposed f or use, under t he gi ven st at i c equi val ent l oads.

Al umi num wi ndow f r ami ng member s must r est r i ct def l ect i ons of t he edges of gl azi ng t hey suppor t t o L/ 60 under t wo t i mes ( 2X) t he gl azi ng r esi st ance per t he r equi r ement s of ASTM F2248 and ASTM E1300. Gl azi ng r esi st ance must be gr eat er t han equi val ent 3- second dur at i on l oadi ng per Wi ndow Schedul e i ndi cat ed on t he dr awi ngs. L denot es t he l engt h of t he gl azi ng suppor t ed edge. ( L i s t o be based on edge l engt h of gl azi ng i n f r ame and not on t he di st ance bet ween anchor s t hat f ast en f r ame t o t he st r uct ur e. )

The gl azi ng f r ame bi t e f or t he wi ndow f r ames must be i n accor dance wi t h

ASTM F2248.

Wi ndow f r ames must be anchor ed t o t he suppor t i ng st r uct ur e wi t h anchor s desi gned t o r esi st t wo t i mes ( 2X) t he gl azi ng r esi st ance i n accor dance with ASTM F2248 and ASTM E1300.

Apr i l 2019 Page 6 SECTI ON 08 51 13

1. 11. 2. 2 Al t er nat e Dynami c Desi gn Anal ysi s Met hod

As an al t er nat i ve t o t he st at i c equi val ent l oad desi gn appr oach descr i bed above, wi ndow f r ami ng member s, anchor s, and gl azi ng may be desi gned usi ng a dynami c anal ysi s t o pr ove t he wi ndow syst em wi l l pr ovi de per f or mance equi val ent t o or bet t er t han a ver y l ow hazar d r at i ng i n accor dance wi t h ASTM F1642 associ at ed wi t h t he appl i cabl e l ow l evel of pr ot ect i on f or t he project.

1. 11. 2. 3 St andar d Ai r bl ast Test Met hod

As an al t er nat i ve t o ei t her of t he Comput at i onal Desi gn Anal ysi s Met hods, each Mi ni mum Ant i t er r or i sm wi ndow t ype must be t est ed f or eval uat i on of hazar ds gener at ed f r om ai r bl ast l oadi ng i n accor dance wi t h ASTM F1642 by an i ndependent t est i ng agency r egul ar l y engaged i n bl ast t est i ng. For pr oposed wi ndow syst ems t hat ar e of t he same t ype as t he t est ed syst em but of di f f er ent s i ze, t he t est r esul t s may be accept ed pr ovi ded t he pr oposed wi ndow si ze i s wi t hi n t he r ange f r om 25 per cent smal l er t o 10 per cent l ar ger i n ar ea, t han t he t est ed wi ndow. Pr oposed wi ndows of a s i ze out si de t hi s r ange r equi r e t est i ng t o eval uat e t hei r hazar d r at i ng.

Test i ng may be by shockt ube or ar ena t est . The t est must be per f or med on t he ent i r e pr oposed wi ndow syst em, t o i ncl ude, but not be l i mi t ed t o, t he gl azi ng, i t s f r ami ng syst em, oper at i ng devi ces, and al l anchor age devi ces. Anchor age of t he wi ndow f r ame or subf r ame must r epl i cat e t he met hod of i nst al l at i on t o be used f or t he pr oj ect . The mi ni mum ai r bl ast l oadi ng par amet er s f or t he t est must be as f ol l ows: Peak posi t i ve pr essur e of 40 kPa and posi t i ve phase i mpul se of 285 kPa- msec. The hazar d r at i ng f or t he pr oposed wi ndow syst ems, as det er mi ned by t he r at i ng cr i t er i a of ASTM F1642, must not exceed t he " Ver y Low Hazar d" r at i ng ( i . e.

t he " No Br eak" , " No Hazar d" , " Mi ni mal Hazar d" and " Ver y Low Hazar d" r at i ngs ar e accept abl e. " Low Hazar d" and " Hi gh Hazar d" r at i ngs ar e unaccept abl e) . Resul t s of wi ndow syst ems pr evi ousl y t est ed by t est pr ot ocol s ot her t han ASTM F1642 may be accept ed pr ovi ded t he r equi r ed l oadi ng, hazar d l evel r at i ng, and si ze l i mi t at i ons st at ed her ei n ar e met .

1. 11. 3 Ai r I nf i l t r at i on

Ai r i nf i l t r at i on must not exceed t he amount est abl i shed by AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 f or each wi ndow t ype.

1. 11. 4 Wat er Penet r at i on

Wat er penet r at i on must not exceed t he amount est abl i shed by AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 f or each wi ndow t ype.

1. 11. 5 Ther mal Per f or mance

Non- r esi dent i al al umi num wi ndows ( i ncl udi ng f r ames and gl ass) must be cer t i f i ed by t he Nat i onal Fenest r at i on Rat i ng Counci l wi t h a whol e- wi ndow Sol ar Heat Gai n Coef f i c i ent ( SHGC) maxi mum of 0. 30 det er mi ned accor di ng t o

NFRC 200 pr ocedur es and a U- f act or maxi mum of 0. 46 Bt u/ hr - f t 2- F i n accor dance wi t h NFRC 100.

Resi dent i al al umi num wi ndows ( i ncl udi ng f r ames and gl ass) must be Ener gy St ar qual i f i ed pr oduct s as appr opr i at e t o Sout h- Cent r al c l i mat e zone. To meet Ener gy St ar cr i t er i a f or t he Sout h- Cent r al c l i mat e zone, t her mal pr oper t i es of wi ndows must not exceed a U- f act or of 0. 35 Bt u/ hr - f t 2-F det er mi ned accor di ng t o NFRC 100, and a sol ar heat gai n coef f i c i ent ( SHGC) of 0. 30 det er mi ned accor di ng t o NFRC 200.

Apr i l 2019 Page 7 SECTI ON 08 51 13

1. 11. 6 Li f e Saf et y Cr i t er i a

Pr ovi de wi ndows t hat conf or m t o NFPA 101 Li f e Saf et y Code when r escue and/ or second means of escape ar e i ndi cat ed.

1. 12 QUALIFICATION

Wi ndow manuf act ur er must speci al i ze i n desi gni ng and manuf act ur i ng t he t ype of al umi num wi ndows speci f i ed i n t hi s sect i on, and have a mi ni mum of 10 year s of document ed successf ul exper i ence. Manuf act ur er must have t he f aci l i t i es capabl e of meet i ng cont r act r equi r ement s, s i ngl e- sour ce r esponsi bi l i t y and war r ant y.

1. 13 WARRANTY

Pr ovi de Manuf act ur er ' s st andar d per f or mance guar ant ees or war r ant i es t hat ext end beyond a 1 year per i od.

PART 2 PRODUCTS

2. 1 PRODUCT SUSTAI NABI LI TY CRI TERI A

For pr oduct s i n t hi s sect i on, wher e appl i cabl e and t o ext ent al l owed by per f or mance cr i t er i a, pr ovi de and document t he f ol l owi ng:

2. 1. 1 Ener gy Ef f i c i ent Equi pment f or Resi dent i al Wi ndows

Pr ovi de Ener gy St ar r esi dent i al wi ndows.

2. 2 WINDOWS

Pr ovi de pr i me wi ndows t hat compl y wi t h AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 and t he r equi r ement s speci f i ed her ei n. I n addi t i on t o compl i ance wi t h AAMA/ WDMA/ CSA 101/ I . S. 2/ A440, wi ndow f r ami ng member s f or each i ndi v i dual l i ght of gl ass must not def l ect t o t he ext ent t hat def l ect i on per pendi cul ar t o t he gl ass l i ght exceeds L/ 175 of t he gl ass edge l engt h when subj ect ed t o uni f or m l oads at speci f i ed desi gn pr essur es. Pr ovi de St r uct ur al cal cul at i ons f or def l ect i on t o subst ant i at e compl i ance wi t h def l ect i on r equi r ement s. Pr ovi de wi ndows of t ypes, per f or mance cl asses, per f or mance gr ades, combi nat i ons, and si zes i ndi cat ed or speci f i ed.

Desi gn wi ndows t o accommodat e har dwar e, gl ass, weat her st r i ppi ng, scr eens, and accessor i es t o be f ur ni shed. Each wi ndow must be a compl et e f act or y assembl ed uni t wi t h or wi t hout gl ass i nst al l ed. Di mensi ons shown ar e mi ni mum. Pr ovi de wi ndows wi t h i nsul at i ng gl ass and t her mal br eak necessar y t o achi eve a mi ni mum Condensat i on Resi st ance Fact or ( CRF) of 60 when t est ed i n accor dance wi t h AAMA 1503.

2. 2. 1 Hung Wi ndows ( H)

Si ngl e Hung, Type H- LC25. Test and r at e sash bal ance t o conf or m wi t h

AAMA 902.

Desi gn wi ndows, mul l i ons, har dwar e, and anchor s t o wi t hst and t he wi nd l oadi ng speci f i ed.

2. 2. 1. 1 Wi ndow Mat er i al s

Wi ndow f r ames and sash member s, mul l i ons, mul l i on cover s, scr een f r ames, Apr i l 2019 Page 8 SECTI ON 08 51 13 and gl azi ng beads must be f abr i cat ed i n accor dance wi t h

AAMA/ WDMA/ CSA 101/ I . S. 2/ A440.

Pr ovi de woven wool pi l e weat her st r i ppi ng 0. 210 i nch t hi ck, conf or mi ng t o AAMA 701/ 702, or pol ypr opyl ene mul t i f i l ament f i ber weat her st r i ppi ng i nst al l ed i n an i nt egr al weat her st r i ppi ng gr oove i n t he sash or f r ame, and f l exi bl e pol yvi nyl chl or i de weat her st r i ppi ng i nst al l ed i n t he s i l l member .

2. 2. 2 Fi xed Wi ndows ( F)

Type F- LC25.

2. 2. 3 For ced Ent r y Resi st ant Wi ndows

I n addi t i on t o meet i ng t he r equi r ement s of AAMA/ WDMA/ CSA 101/ I . S. 2/ A440, wi ndows desi gnat ed f or r esi st ance t o f or ced ent r y must conf or m t o t he r equi r ement s of AAMA 1302. 5.

2. 2. 4 Gl ass and Gl azi ng

Mat er i al s ar e speci f i ed i n Sect i on 08 81 00 GLAZI NG.

2. 2. 5 Caul k i ng and Seal i ng

Ar e speci f i ed i n Sect i on 07 92 00 JOI NT SEALANTS.

2. 2. 6 Weatherstripping

AAMA/ WDMA/ CSA 101/ I . S. 2/ A440.

2. 3 FABRICATION

Fabr i cat i on of wi ndow uni t s must compl y wi t h AAMA/ WDMA/ CSA 101/ I . S. 2/ A440.

2. 3. 1 Pr ovi s i ons f or Gl azi ng

Desi gn wi ndows and r abbet s sui t abl e f or gl ass t hi ckness shown For mi ni mum ant i t er r or i sm wi ndows, at t ach gl azi ng t o i t s suppor t i ng f r ame usi ng st r uct ur al s i l i cone seal ant or adhesi ve gl azi ng t ape i n accor dance with ASTM F2248. Desi gn sash f or out si de doubl e gl azi ng and f or secur i ng gl ass wi t h met al beads or gl azi ng channel s.

2. 3. 2 Weatherstripping

Pr ovi de f or vent i l at i ng sect i ons of al l wi ndows t o ensur e a weat her - t i ght seal meet i ng t he i nf i l t r at i on r equi r ement s speci f i ed i n AAMA/ WDMA/ CSA 101/ I . S. 2/ A440. Pr ovi de easi l y r epl aceabl e f act or y- appl i ed weat her st r i ppi ng. Use mol ded vi nyl , mol ded or mol ded- expanded neopr ene or mol ded or expanded Et hyl ene Pr opyl ene Di ene Ter pol ymer ( EPDM) compr essi on- t ype weat her st r i ppi ng f or compr essi on cont act sur f aces. Use t r eat ed woven pi l e or wool , or pol ypr opyl ene or nyl on pi l e bonded t o nyl on f abr i c and met al or pl ast i c backi ng st r i p weat her st r i ppi ng f or s l i di ng sur f aces. Do no use neopr ene or pol yvi nyl chl or i de weat her st r i ppi ng wher e exposed t o di r ect sunl i ght .

2. 3. 3 Fasteners

Use wi ndow manuf act ur er ' s st andar d f or wi ndows, t r i m, and accessor i es.

Sel f - t appi ng sheet - met al scr ews ar e not accept abl e f or mat er i al mor e t han

Apr i l 2019 Page 9 SECTI ON 08 51 13

1/ 16 i nch t hi ck.

2. 3. 4 Adhesives

Pr ovi de j oi nt seal ant s as speci f i ed i n Sect i on 07 92 00 JOI NT SEALANTS.

For i nt er i or appl i cat i on of j oi nt seal ant s, compl y wi t h appl i cabl e r egul at i ons r egar di ng r educed VOC' s, and as speci f i ed i n Sect i on 07 92 00

JOI NT SEALANTS.

2. 3. 5 Dr i ps and Weep Hol es

Pr ovi de cont i nuous dr i ps over heads of t op vent i l at or s. Wher e f i xed wi ndows adj oi n vent i l at or s, dr i ps must be cont i nuous acr oss t ops of f i xed wi ndows. Pr ovi de dr i ps and weep hol es as r equi r ed t o r et ur n wat er t o t he outside.

2. 3. 6 Combi nat i on Wi ndows

Wi ndows used i n combi nat i on must be f act or y assembl ed of t he same cl ass and gr ade. Wher e f act or y assembl y of i ndi v i dual wi ndows i nt o l ar ger uni t s i s l i mi t ed by t r anspor t at i on consi der at i ons, pr ef abr i cat e, mat ch mar k, t r anspor t , and f i el d assembl e.

2. 3. 7 Mul l i ons and Tr ansom Bar s

Pr ovi de mul l i ons bet ween mul t i pl e wi ndow uni t s t o r esi st t wo t i mes ( 2X) gl azi ng r esi st ance i n accor dance wi t h ASTM F2248 and ASTM E1300. Pr ovi de mul l i ons wi t h a t her mal br eak. Secur e mul l i ons and t r ansom bar s t o adj oi ni ng const r uct i on and wi ndow uni t s i n such a manner as t o per mi t expansi on and cont r act i on and t o f or m a weat her t i ght j oi nt . Pr ovi de mul l i on cover s on t he i nt er i or and ext er i or t o compl et el y c l ose exposed j oi nt s and r ecesses bet ween wi ndow uni t s and t o pr esent a neat appear ance.

2. 3. 8 Accessories

Pr ovi de wi ndows compl et e wi t h necessar y har dwar e, f ast eni ngs, c l i ps, f i ns, anchor s, gl azi ng beads, and ot her appur t enances necessar y f or compl et e i nst al l at i on and pr oper oper at i on. Fur ni sh ext r uded al umi num subf r ame r ecept or s and subsi l l wi t h each wi ndow uni t .

2. 3. 8. 1 Hardware

AAMA/ WDMA/ CSA 101/ I . S. 2/ A440. The i t em, t ype, and f unct i onal char act er i st i cs must be t he manuf act ur er ' s st andar d f or t he par t i cul ar wi ndow t ype. Pr ovi de har dwar e of sui t abl e desi gn and of suf f i c i ent st r engt h t o per f or m t he f unct i on f or whi ch i t i s used. Equi p al l oper at i ng vent i l at or s wi t h a l ock or l at chi ng devi ce whi ch can be secur ed f r om t he i nsi de.

2. 3. 8. 2 Fasteners

Pr ovi de conceal ed anchor s of t he t ype r ecommended by t he wi ndow manuf act ur er f or t he speci f i c t ype of const r uct i on. Anchor s and f ast ener s must be compat i bl e wi t h t he wi ndow and t he adj oi ni ng const r uct i on. Pr ovi de a mi ni mum of t hr ee anchor s f or each j amb l ocat ed appr oxi mat el y 6 i nches f r om each end and at mi dpoi nt .

Apr i l 2019 Page 10 SECTI ON 08 51 13

2. 3. 8. 3 Wi ndow Anchor s

Anchor i ng devi ces f or i nst al l i ng wi ndows must be made of al umi num, cadmi um- pl at ed st eel , st ai nl ess st eel , or z i nc- pl at ed st eel conf or mi ng t o

AAMA/ WDMA/ CSA 101/ I . S. 2/ A440.

2. 3. 9 Finishes

Exposed al umi num sur f aces must be f act or y f i ni shed wi t h an anodi c coat i ng.

Col or must be as i ndi cat ed. Al l wi ndows must have t he same f i ni sh.

2. 3. 9. 1 Anodi c Coat i ng

Cl ean exposed al umi num sur f aces and pr ovi de an anodi zed f i ni sh conf or mi ng to AA DAF45 and AAMA 611. Fi ni sh must be:

a. Ar chi t ect ur al Cl ass I ( 0. 7 mi l or t hi cker ) , desi gnat i on AA- M10- C22- A41, A44, el ect r ol yt i cal l y deposi t ed col or anodi zed.

2. 3. 10 Screens

AAMA/ WDMA/ CSA 101/ I . S. 2/ A440. Pr ovi de one i nsect scr een f or each oper abl e ext er i or sash or vent i l at or . Desi gn scr eens t o be r ewi r abl e, easi l y r emovabl e f r om i nsi de t he bui l di ng, and t o per mi t easy access t o oper at i ng hardware.

2. 4 THERMAL- BARRI ER WI NDOWS

Pr ovi de t her mal - bar r i er wi ndows, compl et e wi t h accessor i es and f i t t i ngs, wher e i ndi cat ed.

Speci f y mat er i al and const r uct i on except as f ol l ows:

a. Al umi num al l oy must be 6063- T6.

b. Fr ame const r uct i on, i ncl udi ng oper abl e sash, must be f act or y- assembl ed and f act or y- seal ed i nner and out er al umi num compl et el y separ at ed f r om met al - t o- met al cont act . Joi n assembl y by a cont i nuous, conceal ed, l ow conduct ance di v i der housed i n an i nt er l ocki ng ext r usi on of t he i nner f r ame. Met al f ast ener s, st r aps, or anchor s must not br i dge t he connect i on bet ween t he i nner and out er f r ame.

c. Oper at i ng har dwar e f or each sash must consi st of spr i ng- l oaded nyl on cushi on bl ocks and pi n l ocks desi gned t o l ock i n pr edet er mi ned locations.

d. Sash must be compl et el y separ at ed f r om met al - t o- met al cont act by means of woven- pi l e weat her st r i ppi ng, pl ast i c, or el ast omer i c separ at i on members.

e. Oper at i ng and st or m sash must be f act or y- gl azed wi t h t he t ype of gl ass i ndi cat ed and of t he qual i t y speci f i ed i n Sect i on 08 81 00 GLAZI NG.

2. 5 MULLIONS

Pr ovi de mul l i ons bet ween mul t i pl e- wi ndow uni t s wher e i ndi cat ed.

Pr ovi de pr of i l es f or mul l i ons and mul l i on cover s, r ei nf or ced as r equi r ed f or t he speci f i ed wi nd l oadi ng, and secur el y anchor ed t o t he adj oi ni ng

Apr i l 2019 Page 11 SECTI ON 08 51 13 const r uct i on. Mul l i on ext r usi on wi l l i ncl ude ser r at i ons or pocket s t o r ecei ve weat her st r i ppi ng, seal ant , or t ape at t he poi nt of cont act wi t h each wi ndow f l ange.

Mul l i on assembl y must i ncl ude al umi num wi ndow cl amps or br acket s scr ewed or bol t ed t o t he mul l i on and t he mul l i on cover .

Mul l i on cover must be scr ew- f ast ened t o t he mul l i on unl ess ot her wi se indicated.

Mul l i on r ei nf or ci ng member s must be f abr i cat ed of t he mat er i al s speci f i ed in AAMA/ WDMA/ CSA 101/ I . S. 2/ A440 and meet t he speci f i ed desi gn l oadi ng.

2. 6 WI NDOW CLEANERS' BOLTS

Pr ovi de wi ndow cl eaner s ' bol t s f or al l wi ndows 7 f eet or hi gher above f i ni shed gr ade, except f or wi ndows t hat can be r emoved and cl eaned f r om t he gr ound or f r om a l ower r oof l evel wi t hout t he use of an ext ensi on l adder . Pr ovi de t wo bol t s f or each si ngl e wi ndow uni t and each f i xed gl ass uni t . Locat e bol t s 44 i nches above t he wi ndow si l l .

Wi ndow cl eaner s ' bol t s must be doubl e- head t ype, AI SI Ser i es 300 cor r osi on- r esi st ant st eel , s i ze and desi gn compl yi ng wi t h I WCA I - 14. 1.

Cont act s i de of t he bol t s must be gr ound t o f i t f l at agai nst wi ndow j ambs. Bol t s must be f act or y- or f i el d- at t ached bef or e wi ndows ar e set .

Rei nf or ce backs of f r ames t o r ecei ve bol t s wi t h 1/ 4 by 6- i nch cor r osi on- r esi st ant st eel or al umi num pl at es bol t ed or wel ded t o t he f r ames at t he f act or y. Speci al wal l anchor s must be pr ovi ded on f r ames at t he poi nt of bol t at t achment .

PART 3 EXECUTI ON

3. 1 INSTALLATION

3. 1. 1 Met hod of I nst al l at i on

I nst al l i n accor dance wi t h t he wi ndow manuf act ur er ' s pr i nt ed i nst r uct i ons and det ai l s. Bui l d i n wi ndows as t he wor k pr ogr esses or i nst al l wi t hout f or c i ng i nt o pr epar ed wi ndow openi ngs. Set wi ndows at pr oper el evat i on, l ocat i on, and r eveal ; pl umb, squar e, l evel , and i n al i gnment ; and br ace, st r ut , and st ay pr oper l y t o pr event di st or t i on and mi sal i gnment . Pr ot ect vent i l at or s and oper at i ng par t s agai nst accumul at i on of di r t and bui l di ng mat er i al s by keepi ng vent i l at or s t i ght l y c l osed and l ocked t o f r ame. Bed scr ews or bol t s i n s i l l member s, j oi nt s at mul l i ons, cont act s of wi ndows wi t h s i l l s , bui l t - i n f i ns, and subf r ames i n mast i c seal ant of a t ype r ecommended by t he wi ndow manuf act ur er . I nst al l and caul k wi ndows i n a manner t hat wi l l pr event ent r ance of wat er and wi nd. Fast en i nsect scr eens secur el y i n pl ace.

Any mat er i al s t hat show vi sual evi dence of bi ol ogi cal gr owt h due t o t he pr esence of moi st ur e must not be i nst al l ed on t he bui l di ng pr oj ect .

3. 1. 2 Di ssi mi l ar Mat er i al s

Wher e al umi num sur f aces ar e i n cont act wi t h, or f ast ened t o masonr y, concr et e, wood, or di ssi mi l ar met al s, except st ai nl ess st eel or z i nc, pr ot ect t he al umi num sur f ace f r om di ssi mi l ar mat er i al s as r ecommended i n t he Appendi x t o AAMA/ WDMA/ CSA 101/ I . S. 2/ A440. Do not coat sur f aces i n cont act wi t h seal ant s af t er i nst al l at i on wi t h any t ype of pr ot ect i ve

Apr i l 2019 Page 12 SECTI ON 08 51 13 material.

3. 1. 3 Anchor s and Fast eni ngs

Make pr ovi s i on f or secur i ng uni t s t o each ot her , t o masonr y, and t o ot her adj oi ni ng const r uct i on. Wi ndows i nst al l ed i n masonr y wal l s must have head and j amb member s desi gned t o r ecess i nt o masonr y wal l not l ess t han 7/ 16 inch.

3. 1. 4 Adj ust ment s Af t er I nst al l at i on

Af t er i nst al l at i on of wi ndows and compl et i on of gl azi ng and f i el d pai nt i ng, adj ust al l vent i l at or s and har dwar e t o oper at e smoot hl y and t o pr ovi de weat her t i ght seal i ng when vent i l at or s ar e c l osed and l ocked.

Lubr i cat e har dwar e and oper at i ng par t s as necessar y. Ver i f y t hat pr oduct s ar e pr oper l y i nst al l ed, connect ed, and adj ust ed.

3. 2 CLEANING

Cl ean i nt er i or and ext er i or sur f aces of wi ndow uni t s of mor t ar , pl ast er , pai nt spat t er i ng spot s, and ot her f or ei gn mat t er t o pr esent a neat appear ance, t o pr event f oul i ng of weat her i ng sur f aces and weat her - st r i ppi ng, and t o pr event i nt er f er ence wi t h t he oper at i on of har dwar e. Repl ace al l st ai ned, di scol or ed, or abr aded wi ndows t hat cannot be r est or ed t o t hei r or i gi nal condi t i on wi t h new wi ndows.

- - End of Sect i on - -