This is a technical specification document for acoustical ceiling systems at Tinker Air Force Base, Oklahoma, dated April 2019.

The specification establishes requirements for sound-controlling ceiling units mechanically mounted on suspension systems for acoustical treatment. Acoustical units must comply with ASTM E1264, Class A standards and achieve a Noise Reduction Coefficient (NRC) of 0.95 minimum when tested on Mounting Type E-400 of ASTM E795, with a light reflectance coefficient (LR-1) of 0.75 or greater. Two unit types are specified: Impact/Abrasion Resistant Units (24 by 24 by 1 inch, non-asbestos mineral composition with hardened mineral surface and white paint finish) and Humidity Resistant Composition Units (24 by 48 inch, non-asbestos mineral or glass fibers with moisture-resistant resin). Both types must have a flame spread rating of Class A (25 or less) and smoke development of 50 or less when tested per ASTM E84. Fire-resistive ceilings must be rated for 1, 1-1/2, 2, 3, or 4 hour endurance per ASTM E119 and achieve a Ceiling Attenuation Class (CAC) of 39 per ASTM E1414/E1414M. The suspension system must conform to ASTM C635/C635M for intermediate-duty systems with standard width flanges of not less than 15/16 inch, aluminum or steel with white baked-enamel finish, and maximum deflection of 1/360 of span length. Hangers must support a minimum 300-pound ultimate vertical load and utilize galvanized steel wire per ASTM A641/A641M (0.08 inch, 12 gauge), galvanized steel straps, threaded steel rods, or carbon-steel eyebolts per ASTM A489. Affirmative procurement requirements mandate that acoustic tiles contain recycled materials consistent with EPA Comprehensive Procurement Guidelines, with minimum content levels of 100 percent post-consumer materials for laminated paperboard, 75 percent slag for rock wool, and 75 percent post-consumer paper for cellulose. Installation must follow ASTM C636/C636M standards, include proper hanger plumbing, wall molding, and acoustic sealant per ASTM C834. Access panels (12 by 12 to 12 by 24 inches) must be numbered and coded to identify systems including fire detection, HVAC, plumbing, and medical piping. Manufacturers must provide warranties extending beyond one year with provisions for repair or replacement of failed panels due to sagging, warping, or grid corrosion, and spare tiles must be furnished at a rate of 5 tiles per 1,000 tiles installed.

View the file

Other files

File Type Posted
03 11 13.00 10.pdf PDF
03 20 00.00 10.pdf PDF
03 30 00.pdf PDF
07 14 00.pdf PDF
07 19 00.pdf PDF
07 21 16.pdf PDF
07 22 00.pdf PDF
07 31 13.pdf PDF
07 52 00.pdf PDF
07 72 20.pdf PDF
08 34 01.pdf PDF
08 34 19.10 20.pdf PDF
08 52 00.pdf PDF
09 29 00.pdf PDF
10 21 13.pdf PDF
10 22 13.pdf PDF
13 34 19.pdf PDF
21 13 13.pdf PDF
23 03 00.pdf PDF
23 05 48.00 40.pdf PDF
23 07 00.pdf PDF
23 09 23.01.pdf PDF
23 34 23.00 40.pdf PDF
23 52 00.pdf PDF
23 65 00.pdf PDF
23 70 03.pdf PDF
26 00 00.00 20.pdf PDF
26 05 48.00 10.pdf PDF
26 29 23.pdf PDF
26 32 14.00 10.pdf PDF
31 23 15.pdf PDF
31 23 16.pdf PDF
32 01 13.pdf PDF
32 11 11.pdf PDF
32 11 29.pdf PDF
32 12 10.1.pdf PDF
32 12 10.2.pdf PDF
32 13 14.pdf PDF
190023 Renovate Restrooms B117 RFIs_FINAL_COR_Signed.pdf PDF
TAFB_Tech_Reqs (Div 02-48).zip ZIP file
Model.zip ZIP file
000_TABLE OF CONTENTS.pdf PDF
01 32 16.00 20.pdf PDF
01 33 16.00 10.pdf PDF
01 42 00.pdf PDF
01 78 00.pdf PDF
Tinker General Requirements Specifications_Nov 2022_Change Log.pdf PDF
Initial Site Visit WWYK190023.pdf PDF
Att12_190023_Drawings_Final.pdf PDF
Section L - Instructions to Offerors.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Ti nker AFB, OK TAFB Techni cal Spr ci f i cat i ons 2019

SECTI ON 09 51 00

ACOUSTI CAL CEI LI NGS

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.

ASTM I NTERNATI ONAL ( ASTM)

ASTM A1008/ A1008M ( 2015) St andar d Speci f i cat i on f or St eel , Sheet , Col d- Rol l ed, Car bon, St r uct ur al , Hi gh- St r engt h Low- Al l oy and Hi gh- St r engt h Low- Al l oy wi t h I mpr oved For mabi l i t y , Sol ut i on Har dened, and Bake Har dened

ASTM A167 ( 2011) St andar d Speci f i cat i on f or St ai nl ess and Heat - Resi st i ng Chr omi um- Ni ckel St eel Pl at e, Sheet , and Strip

ASTM A489 ( 2012) St andar d Speci f i cat i on f or Car bon St eel Li f t i ng Eyes

ASTM A580/ A580M ( 2015) St andar d Speci f i cat i on f or St ai nl ess St eel Wi r e

ASTM A641/ A641M ( 2009a; R 2014) St andar d Speci f i cat i on f or Zi nc- Coat ed ( Gal vani zed) Car bon St eel Wi r e

ASTM A653/ A653M ( 2015; E 2016) St andar d Speci f i cat i on f or St eel Sheet , Zi nc- Coat ed ( Gal vani zed) or Zi nc- I r on Al l oy- Coat ed ( Gal vanneal ed) by t he Hot - Di p Pr ocess

ASTM B633 ( 2015) St andar d Speci f i cat i on f or El ect r odeposi t ed Coat i ngs of Zi nc on I r on and St eel

ASTM C423 ( 2009a) Sound Absor pt i on and Sound Absor pt i on Coef f i c i ent s by t he Rever ber at i on Room Met hod

ASTM C635/ C635M ( 2013a) Manuf act ur e, Per f or mance, and Test i ng of Met al Suspensi on Syst ems f or Acoust i cal Ti l e and Lay- I n Panel Cei l i ngs

ASTM C636/ C636M ( 2013) St andar d Pr act i ce f or I nst al l at i on of Met al Cei l i ng Suspensi on Syst ems f or Acoust i cal Ti l e and Lay- I n Panel s

ASTM C834 ( 2014) Lat ex Seal ant s

Apr i l 2019 Page 1 SECTI ON 09 51 00

ASTM E119 ( 2016) St andar d Test Met hods f or Fi r e Test s of Bui l di ng Const r uct i on and Materials

ASTM E1264 ( 2014) Acoust i cal Cei l i ng Pr oduct s

ASTM E1414/ E1414M ( 2011a; E 2014) Ai r bor ne Sound At t enuat i on Bet ween Rooms Shar i ng a Common Cei l i ng Plenum

ASTM E1477 ( 1998a; R 2013) Lumi nous Ref l ect ance Fact or of Acoust i cal Mat er i al s by Use of I nt egr at i ng- Spher e Ref l ect omet er s

ASTM E580/ E580M ( 2014) St andar d Pr act i ce f or I nst al l at i on of Cei l i ng Suspensi on Syst ems f or Acoust i cal Ti l e and Lay- i n Panel s i n Ar eas Subj ect t o Ear t hquake Gr ound Mot i ons

ASTM E795 ( 2005; R 2012) Mount i ng Test Speci mens Dur i ng Sound Absor pt i on Test s

ASTM E84 ( 2015b) St andar d Test Met hod f or Sur f ace Bur ni ng Char act er i st i cs of Bui l di ng Materials

SCI ENTI FI C CERTI FI CATI ON SYSTEMS ( SCS)

SCS SCS Gl obal Ser vi ces ( SCS) I ndoor Advant age

U. S. DEPARTMENT OF DEFENSE ( DOD)

UFC 3- 310- 04 ( 2013) Sei smi c Desi gn f or Bui l di ngs

UL ENVI RONMENT ( ULE)

ULE Gr eenguar d UL Gr eenguar d Cer t i f i cat i on Pr ogr am

UNDERWRI TERS LABORATORI ES ( UL)

UL Fi r e Resi st ance ( 2014) Fi r e Resi st ance Di r ect or y

1. 2 SYSTEM DESCRI PTI ON

Pr ovi de sound cont r ol l i ng uni t s mechani cal l y mount ed on a cei l i ng suspensi on syst em f or acoust i cal t r eat ment . The uni t s i ze, t ext ur e, f i ni sh, and col or must be as speci f i ed. The l ocat i on and ext ent of acoust i cal t r eat ment shal l be as shown on t he appr oved det ai l dr awi ngs.

Submi t dr awi ngs showi ng suspensi on syst em, met hod of anchor i ng and f ast eni ng, det ai l s, and r ef l ect ed cei l i ng pl an. Coor di nat e wi t h par agr aph RECLAMATI ON PROCEDURES f or r ecl amat i on of mi ner al f i ber acoust i cal cei l i ng panel s t o be r emoved f r om t he j ob s i t e.

1. 2. 1 Fi r e Resi st i ve Cei l i ngs

Rat e acoust i cal cei l i ng syst ems, i ndi cat ed as f i r e r esi st ant , f or f i r e endur ance as speci f i ed when t est ed i n accor dance wi t h ASTM E119. Test suspended cei l i ng wi t h a speci men r oof or f l oor assembl y r epr esent at i ve of

Apr i l 2019 Page 2 SECTI ON 09 51 00 t he i ndi cat ed const r uct i on, i ncl udi ng mechani cal and el ect r i cal wor k wi t hi n cei l i ng space openi ngs f or l i ght f i x t ur es, and ai r out l et s, and access panel s. Pr ovi de cei l i ng assembl y r at i ng f or 1, 1- 1/ 2, 2, 3, or 4 hour , conceal ed gr i d or exposed gr i d syst em as shown on dr awi ngs. Pr ovi de acoust i cal uni t s wi t h a f l ame spr ead of 25 or l ess and smoke devel opment of 50 or l ess when t est ed i n accor dance wi t h ASTM E84.

1. 2. 2 Cei l i ng At t enuat i on Cl ass and Test

Pr ovi de a cei l i ng syst em wi t h an at t enuat i on c l ass ( CAC) of 39 when det er mi ned i n accor dance wi t h ASTM E1414/ E1414M. Pr ovi de f i xt ur e at t enuat or s over l i ght f i x t ur es and ot her cei l i ng penet r at i ons, and pr ovi de acoust i cal bl anket i nsul at i on adj acent t o par t i t i ons, as r equi r ed t o achi eve t he speci f i ed CAC. Pr ovi de t est cei l i ng cont i nuous at t he par t i t i on and assembl ed i n t he suspensi on syst em i n t he same manner t hat t he cei l i ng wi l l be i nst al l ed on t he pr oj ect .

1. 2. 3 Cei l i ng Sound Absor pt i on

Det er mi ne t he Noi se Reduct i on Coef f i c i ent ( NRC) i n accor dance wi t h ASTM C423 Test Met hod.

1. 2. 4 Li ght Ref l ect ance

Det er mi ne l i ght r ef l ect ance f act or i n accor dance wi t h ASTM E1477 Test Method.

1. 2. 5 Ot her Submi t t al s Requi r ement s

The f ol l owi ng shal l be submi t t ed:

a. Manuf act ur er ' s dat a i ndi cat i ng per cent age of r ecycl e mat er i al i n acoust i c cei l i ng t i l es t o ver i f y af f i r mat i ve pr ocur ement compl i ance.

b. Tot al wei ght and vol ume quant i t i es of acoust i c cei l i ng t i l es wi t h r ecycl e mat er i al .

c. Manuf act ur er ' s cat al og showi ng UL cl assi f i cat i on of f i r e- r at ed cei l i ngs gi v i ng mat er i al s, const r uct i on det ai l s, t ypes of f l oor and r oof const r uct i ons t o be pr ot ect ed, and UL desi gn number and f i r e pr ot ect i on t i me r at i ng f or each r equi r ed f l oor or r oof const r uct i on and acoust i c cei l i ng assembl y.

d. Repor t s by an i ndependent t est i ng l abor at or y at t est i ng t hat acoust i cal cei l i ng syst ems meet speci f i ed f i r e endur ance and sound t r ansmi ssi on r equi r ement s. Dat a at t est i ng t o conf or mance of t he pr oposed syst em t o Under wr i t er s Labor at or i es r equi r ement s f or t he f i r e endur ance r at i ng l i s t ed i n UL Fi r e Resi st ance may be submi t t ed i n l i eu of t est r epor t s.

e. Cer t i f i cat e at t est i ng t hat t he mi ner al based acoust i cal uni t s f ur ni shed f or t he pr oj ect cont ai n r ecycl ed mat er i al and showi ng an est i mat ed per cent of such mat er i al .

1. 3 SUBMITTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;

submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t al s wi t h an " S" ar e f or i ncl usi on i n t he Sust ai nabi l i t y Not ebook, i n conf or mance t o Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG.

Apr i l 2019 Page 3 SECTI ON 09 51 00

Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL

PROCEDURES:

SD- 02 Shop Dr awi ngs

Appr oved Det ai l Dr awi ngs

SD- 03 Pr oduct Dat a

Acoust i cal Cei l i ng Syst ems

SD- 04 Sampl es

Acoust i cal Uni t s Acoust i c Cei l i ng Ti l es

SD- 06 Test Repor t s

Fi r e Resi st i ve Cei l i ngs Cei l i ng At t enuat i on Cl ass and Test

SD- 07 Cer t i f i cat es

Acoust i cal Uni t s Acoust i c Cei l i ng Ti l es

1. 4 DELI VERY, STORAGE. AND HANDLI NG

Del i ver mat er i al s t o t he s i t e i n t he manuf act ur er ' s or i gi nal unopened cont ai ner s wi t h br and name and t ype cl ear l y mar ked. Car ef ul l y handl e and st or e mat er i al s i n dr y, wat er t i ght encl osur es. I mmedi at el y bef or e i nst al l at i on, st or e acoust i cal uni t s f or not l ess t han 24 hour s at t he same t emper at ur e and r el at i ve humi di t y as t he space wher e t hey wi l l be i nst al l ed i n or der t o assur e pr oper t emper at ur e and moi st ur e accl i mat i on.

1. 5 ENVI RONMENTAL REQUI REMENTS

Mai nt ai n a uni f or m t emper at ur e of not l ess t han 60 degr ees F nor mor e t han 85 degr ees F and a r el at i ve humi di t y of not mor e t han 70 per cent f or 24 hour s bef or e, dur i ng, and 24 hour s af t er i nst al l at i on of acoust i cal uni t s.

1. 6 SCHEDULING

Compl et e and dr y i nt er i or f i ni sh wor k such as pl ast er i ng, concr et e and t er r azzo wor k bef or e cei l i ng i nst al l at i on. Compl et e mechani cal , el ect r i cal , and ot her wor k above t he cei l i ng l i ne; i nst al l and st ar t oper at i ng heat i ng, vent i l at i ng, and ai r condi t i oni ng syst ems i n or der t o mai nt ai n t emper at ur e and humi di t y r equi r ement s.

1. 7 WARRANTY

Pr ovi de manuf act ur er ' s st andar d per f or mance guar ant ees or war r ant i es t hat ext end beyond a one year per i od. I ncl ude an agr eement t o r epai r or r epl ace acoust i cal panel s t hat f ai l wi t hi n t he war r ant y per i od i n t he st andar d per f or mance guar ant ee or war r ant y. Fai l ur es i ncl ude, but ar e not l i mi t ed t o, saggi ng and war pi ng of panel s; r ust i ng and manuf act ur er s def ect s of gr i d syst em.

Apr i l 2019 Page 4 SECTI ON 09 51 00

1. 8 EXTRA MATERI ALS

Fur ni sh spar e t i l es, f r om t he same l ot as t hose i nst al l ed, of each col or at t he r at e of 5 t i l es f or each 1000 t i l es i nst al l ed.

PART 2 PRODUCTS

2. 1 ACOUSTI CAL UNI TS

Compl y wi t h EPA r equi r ement s i n accor dance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG. Submi t t wo sampl es of each t ype of acoust i cal uni t and each t ype of suspensi on gr i d t ee sect i on showi ng t ext ur e, f i ni sh, and col or . Conf or m acoust i cal uni t s t o ASTM E1264, Cl ass A, and t he f ol l owi ng r equi r ement s:

2. 1. 1 Af f i r mat i ve Pr ocur ement

Mi ner al Wool , Cel l ul ose, and Lami nat ed Paper boar d used i n acoust i c cei l i ng t i l es ar e mat er i al s l i s t ed i n t he EPA' s Compr ehensi ve Pr ocur ement Gui del i nes ( CPG) ( http://www.epa.gov/cpg/ ) . EPA' s r ecommended Recover ed Mat er i al s Cont ent Level s f or Mi ner al Wool , Cel l ul ose, St r uct ur al Fi ber boar d and Lami nat ed Paper boar d ar e:

Product Material Per cent of Post Consumer Mat er i al s

Per cent of Tot al Recover ed Mat er i al s

Lami nat e Paper boar d Post Consumer Paper 100 100

Rock Wool Slag 75

Cellulose Post Consumer Paper 75 75

a. The r ecommended r ecover ed mat er i al s cont ent l evel s ar e based on t he wei ght ( not vol ume) of mat er i al s i n t he i nsul at i ng cor e onl y.

b. Submi t r ecycl ed mat er i al cont ent dat a f or acoust i c cei l i ng t i l es i ndi cat i ng compl i ance wi t h af f i r mat i ve pr ocur ement .

c. Submi t t ot al wei ght and vol ume quant i t i es of acoust i c cei l i ng t i l es wi t h r ecycl e mat er i al .

2. 1. 2 I mpact / Abr asi on Resi st ant Uni t s

2. 1. 2. 1 Type

Non- asbest os mi ner al composi t i on wi t h a har dened mi ner al sur f ace and f act or y appl i ed whi t e pai nt f i ni sh. Pr ovi de a sur f ace r esi st ant t o i mpact and abr asi on.

2. 1. 2. 2 Fl ame Spr ead

Cl ass A, 25 or l ess

2. 1. 2. 3 Pattern

As i ndi cat ed.

Apr i l 2019 Page 5 SECTI ON 09 51 00

2. 1. 2. 4 Mi ni mum NRC

. 95 when t est ed on Mount i ng Type E- 400 of ASTM E795.

2. 1. 2. 5 Mi ni mum Li ght Ref l ect ance Coef f i c i ent

LR- 1, 0. 75 or gr eat er

2. 1. 2. 6 Nomi nal Si ze

24 by 24 by 1 i nch

2. 1. 2. 7 Edge Det ai l

Squar e or bevel ed as i ndi cat ed.

2. 1. 2. 8 Joi nt Det ai l

Tr i mmed and but t ed

2. 1. 3 Humi di t y Resi st ant Composi t i on Uni t s

2. 1. 3. 1 Type

Non- asbest os mi ner al or gl ass f i ber s bonded wi t h cer ami c, moi st ur e r esi st ant t her mo- set t i ng r esi n, or ot her moi st ur e r esi st ant mat er i al and havi ng a f act or y appl i ed whi t e pai nt f i ni sh. Pr ovi de panel s t hat do not sag or war p under condi t i ons of heat , hi gh humi di t y or chemi cal f umes.

2. 1. 3. 2 Fl ame Spr ead

Cl ass: A, 25 or l ess

2. 1. 3. 3 Pattern

As i ndi cat ed.

2. 1. 3. 4 Mi ni mum NRC

Mi ni mum . 95 when t est ed on Mount i ng Type E- 400 of ASTM E795.

2. 1. 3. 5 Mi ni mum Li ght Ref l ect ance Coef f i c i ent

LR- 1, 0. 75 or gr eat er

2. 1. 3. 6 Nomi nal Si ze

24 by 48, or as i ndi cat ed. i nch

2. 1. 3. 7 Edge Det ai l

Square

2. 2 SUSPENSI ON SYSTEM

Pr ovi de st andar d f i r e- r esi st i ve st andar d wi dt h f l ange as shown on dr awi ngs suspensi on syst em conf or mi ng t o ASTM C635/ C635M f or i nt er medi at e- dut y syst ems . Pr ovi de sur f aces exposed t o v i ew of al umi num or st eel wi t h a f act or y- appl i ed whi t e baked- enamel f i ni sh . Pr ovi de wal l mol di ng havi ng a

Apr i l 2019 Page 6 SECTI ON 09 51 00 f l ange of not l ess t han 15/ 16 i nch . Pr ovi de st andar d cor ner s.

Suspended cei l i ng f r ami ng syst em must have t he capabi l i t y t o suppor t t he f i ni shed cei l i ng, l i ght f i x t ur es, ai r di f f user s, and accessor i es, as shown. Pr ovi de a suspensi on syst em wi t h a maxi mum def l ect i on of 1/ 360 of t he span l engt h. Conf or m sei smi c det ai l s t o t he gui dance i n UFC 3- 310- 04 and ASTM E580/ E580M .

2. 3 HANGERS

Pr ovi de hanger s and at t achment capabl e of suppor t i ng a mi ni mum 300 pound ul t i mat e ver t i cal l oad wi t hout f ai l ur e of suppor t i ng mat er i al or attachment.

2. 3. 1 Wires

Conf or m wi r es t o ASTM A641/ A641M, Cl ass 1, 0. 08 i nch ( 12 gauge) i n diameter.

2. 3. 2 Straps

Pr ovi de st r aps of 1 by 3/ 16 i nch gal vani zed st eel conf or mi ng t o ASTM A653/ A653M, wi t h a l i ght commer ci al z i nc coat i ng or ASTM A1008/ A1008M wi t h an el ect r odeposi t ed z i nc coat i ng conf or mi ng t o ASTM B633, Type RS.

2. 3. 3 Rods

Pr ovi de 3/ 16 i nch di amet er t hr eaded st eel r ods, z i nc or cadmi um coat ed.

2. 3. 4 Eyebolts

Pr ovi de eyebol t s of wel dl ess, f or ged- car bon- st eel , wi t h a st r ai ght - shank i n accor dance wi t h ASTM A489. Eyebol t s i ze must be a mi ni mum 1/ 4 i nch, z i nc coat ed or cadmi um pl at ed.

2. 3. 5 Masonr y Anchor age Devi ces

Compl y wi t h ASTM C636/ C636M f or anchor age devi ces f or eyebol t s, machi ne scr ews, and wood scr ews.

2. 4 ACCESS PANELS

Pr ovi de access panel s t hat mat ch adj acent acoust i cal uni t s, desi gned and equi pped wi t h sui t abl e f r ami ng and f ast eni ngs f or r emoval and r epl acement wi t hout damage. Si ze panel t o be not l ess t han 12 by 12 i nch or mor e t han 12 by 24 i nch.

a. At t ach an i dent i f i cat i on pl at e of 0. 032 i nch t hi ck al umi num, 3/ 4 i nch i n di amet er , st amped wi t h t he l et t er s " AP" and f i ni shed t he same as t he uni t , near one cor ner on t he f ace of each access panel .

b. I dent i f y cei l i ng access panel by a number ut i l i z i ng whi t e i dent i f i cat i on pl at es or pl ast i c but t ons wi t h cont r ast i ng numer al s.

Pr ovi de pl at es or but t ons of mi ni mum 1 i nch di amet er and secur el y at t ached t o one cor ner of each access uni t . Pr ovi de a t ypewr i t t en car d f r amed under gl ass l i s t i ng t he code i dent i f i cat i on number s and cor r espondi ng syst em descr i pt i ons l i s t ed above. Mount t he f r amed car d wher e di r ect ed and f ur ni sh a dupl i cat e car d t o t he Cont r act i ng Of f i cer . Code i dent i f i cat i on syst em i s as f ol l ows:

Apr i l 2019 Page 7 SECTI ON 09 51 00

1 Fi r e det ect i on/ al ar m syst em

2 Ai r condi t i oni ng cont r ol s

3 Pl umbi ng syst em

4 Heat i ng and st eam syst ems

5 Ai r condi t i oni ng duct syst em

6 Spr i nkl er syst em

7 I nt er communi cat i on syst em

8 Nur se' s cal l syst em

9 Pneumat i c t ube syst em

10 Medi cal pi pi ng syst em

11 Pr ogr am ent er t ai nment

12 Tel ephone j unct i on boxes

13 Det ect or X- r ay

2. 5 ADHESIVE

Use adhesi ve as r ecommended by t i l e manuf act ur er .

2. 6 FINISHES

Use manuf act ur er ' s st andar d t ext ur es, pat t er ns and f i ni shes as speci f i ed f or acoust i cal uni t s and suspensi on syst em member s. Tr eat cei l i ng suspensi on syst em component s t o i nhi bi t cor r osi on.

2. 7 COLORS AND PATTERNS

Use col or s and pat t er ns f or acoust i cal uni t s and suspensi on syst em component s as speci f i ed i n Sect i on 09 06 90 SCHEDULES FOR PAI NTI NG AND

COATI NG .

2. 8 ACOUSTI CAL SEALANT

Conf or m acoust i cal seal ant t o ASTM C834, nonst ai ni ng.

PART 3 EXECUTI ON

3. 1 INSTALLATION

Exami ne sur f aces t o r ecei ve di r ect l y at t ached acoust i cal uni t s f or unevenness, i r r egul ar i t i es, and dampness t hat woul d af f ect qual i t y and execut i on of t he wor k. Ri d ar eas, wher e acoust i cal uni t s wi l l be cement ed, of oi l s , f or m r esi due, or ot her mat er i al s t hat r educe bondi ng capabi l i t i es of t he adhesi ve. Compl et e and dr y i nt er i or f i ni sh wor k such as pl ast er i ng, concr et e, and t er r azzo wor k bef or e i nst al l at i on. Compl et e and appr ove mechani cal , el ect r i cal , and ot her wor k above t he cei l i ng l i ne pr i or t o t he st ar t of acoust i cal cei l i ng i nst al l at i on. Pr ovi de acoust i cal

Apr i l 2019 Page 8 SECTI ON 09 51 00 wor k compl et e wi t h necessar y f ast eni ngs, c l i ps, and ot her accessor i es r equi r ed f or a compl et e i nst al l at i on. Do not expose mechani cal f ast eni ngs i n t he f i ni shed wor k. Lay out hanger s f or each i ndi v i dual r oom or space.

Pr ovi de hanger s t o suppor t f r ami ng ar ound beams, duct s, col umns, gr i l l es, and ot her penet r at i ons t hr ough cei l i ngs. Keep mai n r unner s and car r y i ng channel s c l ear of abut t i ng wal l s and par t i t i ons. Pr ovi de at l east t wo mai n r unner s f or each cei l i ng span. Wher ever r equi r ed t o bypass an obj ect wi t h t he hanger wi r es, i nst al l a subsuspensi on syst em so t hat al l hanger wi r es wi l l be pl umb.

3. 1. 1 Suspensi on Syst em

I nst al l suspensi on syst em i n accor dance wi t h ASTM C636/ C636M and as speci f i ed her ei n. Do not suspend hanger wi r es or ot her l oads f r om under si de of st eel decki ng.

3. 1. 1. 1 Pl umb Hanger s

I nst al l hanger s pl umb and not pr essi ng agai nst i nsul at i on cover i ng duct s and pi pes. Wher e l i ght i ng f i x t ur es ar e suppor t ed f r om t he suspended cei l i ng syst em, pr ovi de hanger s at a mi ni mum of f our hanger s per f i x t ur e and l ocat ed not mor e t han 6 i nch f r om each cor ner of each f i xt ur e.

3. 1. 1. 2 Spl ayed Hanger s

Wher e hanger s must be spl ayed ( s l oped or s l ant ed) ar ound obst r uct i ons, of f set t he r esul t i ng hor i zont al f or ce by br aci ng, count er spl ayi ng, or ot her accept abl e means.

3. 1. 2 Wal l Mol di ng

Pr ovi de wal l mol di ng wher e cei l i ngs abut ver t i cal sur f aces. Mi t er cor ner s wher e wal l mol di ngs i nt er sect or i nst al l cor ner caps. Secur e wal l mol di ng not mor e t han 3 i nch f r om ends of each l engt h and not mor e t han 16 i nch on cent er s bet ween end f ast eni ngs. Pr ovi de wal l mol di ng spr i ngs at each acoust i cal uni t i n semi - exposed or conceal ed syst ems.

3. 1. 3 Acoust i cal Uni t s

I nst al l acoust i cal uni t s i n accor dance wi t h t he appr oved i nst al l at i on i nst r uct i ons of t he manuf act ur er . Ensur e t hat edges of acoust i cal uni t s ar e i n c l ose cont act wi t h met al suppor t s, wi t h each ot her , and i n t r ue al i gnment . Ar r ange acoust i cal uni t s so t hat uni t s l ess t han one- hal f wi dt h ar e mi ni mi zed. Hol d uni t s i n exposed- gr i d syst em i n pl ace wi t h manuf act ur er ' s st andar d hol d- down cl i ps, i f uni t s wei gh l ess t han 1 psf or i f r equi r ed f or f i r e r esi st ance r at i ng.

3. 1. 4 Caulking

Seal al l j oi nt s ar ound pi pes, duct s or el ect r i cal out l et s penet r at i ng t he cei l i ng. Appl y a cont i nuous r i bbon of acoust i cal seal ant on ver t i cal web of wal l or edge mol di ngs.

3. 1. 5 Adhesi ve Appl i cat i on

Wi pe back of t i l e t o r emove accumul at ed dust . Daub acoust i cal uni t s on back si de wi t h f our equal daubs of adhesi ve. Appl y daubs near cor ner s of t i l es. Ensur e t hat cont act ar ea of each daub i s at l east 2 i nch di amet er i n f i nal posi t i on. Pr ess uni t s i nt o pl ace, al i gni ng j oi nt s and abut t i ng

Apr i l 2019 Page 9 SECTI ON 09 51 00 uni t s t i ght and uni f or m wi t hout di f f er ences i n j oi nt wi dt hs.

3. 2 CEI LI NG ACCESS PANELS

Locat e cei l i ng access panel s di r ect l y under t he i t ems whi ch r equi r e access.

3. 3 CLEANING

Fol l owi ng i nst al l at i on, c l ean di r t y or di scol or ed sur f aces of acoust i cal uni t s and l eave t hem f r ee f r om def ect s. Remove uni t s t hat ar e damaged or i mpr oper l y i nst al l ed and pr ovi de new uni t s as di r ect ed.

3. 4 RECLAMATI ON PROCEDURES

Neat l y st ack cei l i ng t i l e, desi gnat ed f or r ecycl i ng by t he Cont r act i ng Of f i cer , on 4 by 4 f oot pal l et s not hi gher t han 4 f oot . Panel s must be compl et el y dr y. Shr i nk wr ap and symmet r i cal l y st ack pal l et s on t op of each ot her wi t hout f al l i ng over .

- - End of Sect i on - -