190023 Reno Restrooms B117 Pre Bid RFI Follow Up_COR_Signed.pdf
PDF 187 KB Posted
- Solicitation number
- FA813726R0030
About this file
This is a Request for Information (RFI) issued by the U.S. Air Force for solicitation FA8137-26-R-0030 concerning the renovation of men's and women's restrooms/showers in Building 117 at Tinker Air Force Base. The RFI, dated June 11, 2026, addresses a discrepancy between the number of technical specification sections identified as applicable to the project and those actually included in the specification package.
The Government identified thirty (30) applicable technical specification sections listed in Statement of Work (SOW) Appendix B; however, the specification package contains one hundred fifty-four (154) technical specification files. The Contractor submitted three questions requesting confirmation that one hundred twenty-four (124) specification sections—covering divisions such as Concrete, Masonry, Metals, Wood/Plastics, Thermal/Moisture Protection, Openings, Finishes, Specialties, Special Construction, Fire Suppression, Plumbing, HVAC, Electrical, Electronic Safety and Security, Earthwork, Exterior Improvements, and Utilities—are not applicable to the restroom renovation project and should be excluded from compliance requirements. The Government, through the Contracting Officer Representative (COR), confirmed that the listed specifications are not applicable and that the thirty (30) sections in SOW Appendix B constitute the complete and controlling set of applicable specifications. The Contractor also reserved the right to submit additional RFIs upon receipt and review of the applicable specification sections, noting that project specifications were not available in the initial bid files.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment FA813726R00300001 SF 30.pdf | ||
| 23 08 00.pdf | ||
| 23 35 00.pdf | ||
| 07 60 00.pdf | ||
| 03 39 00.00 10.pdf | ||
| 32 01 14.pdf | ||
| 32 12 15.pdf | ||
| 07 42 13.pdf | ||
| 26 51 00.pdf | ||
| 33 11 00.pdf | ||
| 26 00 00.00 20.pdf | ||
| 10 21 13.pdf | ||
| 23 82 16.00 40.pdf | ||
| 32 13 14.pdf | ||
| 09 51 00.pdf | ||
| 08 41 13.pdf | ||
| 32 12 10.1.pdf | ||
| 07 14 00.pdf | ||
| 23 52 00.pdf | ||
| 08 34 19.10 20.pdf | ||
| 08 51 23.pdf | ||
| 07 41 13.pdf | ||
| 07 24 00.pdf | ||
| 05 50 13.pdf | ||
| 26 20 00.pdf | ||
| 26 23 00.pdf | ||
| 23 05 15.pdf | ||
| 23 64 26.pdf | ||
| 23 00 00.pdf | ||
| 07 61 14.00 20.pdf | ||
| 03 62 16.pdf | ||
| 32 92 23.pdf | ||
| 10 14 00.10.pdf | ||
| 32 01 16.pdf | ||
| 09 90 00.pdf | ||
| 06 41 16.00 10.pdf | ||
| 23 31 13.00 40.pdf | ||
| 26 41 00.pdf | ||
| 09 72 00.pdf | ||
| 05 40 00.pdf | ||
| 000_TABLE OF CONTENTS Technical.pdf | ||
| 10 44 16.pdf | ||
| 32 11 23.pdf | ||
| 08 11 13.pdf | ||
| 07 31 13.pdf | ||
| 03 20 00.00 10.pdf | ||
| 09 29 00.pdf | ||
| 08 34 01.pdf | ||
| 08 52 00.pdf | ||
| 23 70 03.pdf |
Show 40 more
Latest 50 of 184 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFI
WWYK190023 11 June 2026 Solicitation FA8137-26-R-0030
Per SOW Section 5.2 and Appendix B, the Government identified thirty (30) technical specification sections developed by the Government and applicable to the work of this project. The Government’s specification package, however, contains one hundred fifty-four (154) technical specification files — substantially more than the thirty (30) sections listed in Appendix B.
The following one hundred twenty-four (124) technical specification sections were furnished in the specification package but are not listed in SOW Appendix B. Based on the Contractor’s review of the SOW and the project drawings, these sections do not appear to be within the scope of work for this project (an interior renovation of the men’s and women’s restrooms/showers in B117).
Question 1: Please confirm that the specification sections listed below are NOT applicable to this project and are not part of the scope of work, and that the thirty (30) specification sections listed in SOW Appendix B are the complete and controlling set of applicable specifications for this project.
Confirmed. -DBS
Question 2: This is a bid-build project with no design responsibility assigned to the Contractor other than delegated design outlined in SOW, paragraph 3.5, Working Documents. Accordingly, the Contractor requests that the Government affirmatively identify the complete and definitive list of specification sections the Contractor is required to comply with. Determination of specification applicability is a design/Government function and should not be left to the Contractor’s interpretation. If the Government considers any section below to be applicable, please identify the section and the associated scope so the Contractor may price the work accordingly. All spec requirements are listed on the SOW. -DBS
Question 3. Spec Section 33 11 00 – a specification file for this section was furnished in the package, but the section does not appear on the Government Table of Contents (Tinker AFB Technical Specifications, April 2019) and is not listed in Appendix B. As a result, the package contains 154 specification files while the Table of Contents lists 153 sections. Please confirm this section is not applicable, and please confirm whether any additional specification sections exist that were not indexed on the Table of Contents. -Below listed specs are N/A. -DBS
Specification sections requested to be confirmed NOT applicable:
Division 03 - CONCRETE
1. 03 11 13.00 10 Structural Cast-in-Place Concrete Forming
2. 03 20 00.00 10 Concrete Reinforcing
3. 03 39 00.00 10 Concrete Curing
4. 03 62 16 Metallic Non-Shrink Grouting Division 04 - MASONRY
5. 04 20 00 Unit Masonry
Division 05 - METALS
6. 05 05 23.16 Structural Welding
7. 05 12 00 Structural Steel
8. 05 21 00 Steel Joist Framing
9. 05 30 00 Steel Decks
10. 05 40 00 Cold-Formed Metal Framing
11. 05 50 13 Miscellaneous Metal Fabrications
Division 06 - WOOD, PLASTICS, AND COMPOSITES
28. 06 41 16.00 10 Plastic-Laminate-Clad Architectural Cabinets
29. 06 61 16 Solid Surfacing Fabrications
Division 07 - THERMAL AND MOISTURE PROTECTION
14. 07 12 00 Built-Up Bituminous Waterproofing
15. 07 14 00 Fluid-Applied Waterproofing
Solicitation FA8137-26-R-0030
16. 07 19 00 Water Repellants
17. 07 22 00 Roof and Deck Insulation
18. 07 24 00 Exterior Insulation and Finish Systems
19. 07 31 13 Asphalt Shingles
20. 07 41 13 Metal Roof Panels
21. 07 42 13 Metal Wall Panels
22. 07 42 63 Fabricated Wall Panel Assemblies
23. 07 51 13 Built-Up Asphalt Roofing
24. 07 52 00 Modified Bituminous Membrane Roofing
25. 07 53 23 Ethylene-Propylene-Diene-Monomer Roofing
26. 07 54 19 Polyvinyl-Chloride Roofing
27. 07 60 00 Flashing and Sheet Metal
45. 07 61 14.00 20 Steel Standing Seam Roofing
46. 07 72 20 Gravity-Type Roof Ventilators
47. 07 62 13 Copper Sheet Metal Flashing and Trim
Division 08 - OPENINGS
31. 08 11 16 Aluminum Doors and Frames
32. 08 33 23 Overhead Coiling Doors
33. 08 34 01 Forced Entry Resistant Components
34. 08 34 19.10 20 Rolling Service and Fire Doors
35. 08 36 13 Sectional Overhead Doors
36. 08 41 13 Aluminum-Framed Entrances and Storefronts
37. 08 51 13 Aluminum Windows
38. 08 51 23 Steel Windows
39. 08 52 00 Wood Windows
40. 08 56 53 Blast Resistant Tempered Glass Windows
41. 08 81 00 Glazing
Division 09 - FINISHES
42. 09 65 00 Resilient Flooring
43. 09 68 00 Carpeting
44. 09 72 00 Wallcoverings
Division 10 - SPECIALTIES
49. 10 14 00.10 Exterior Signage
50. 10 21 13 Toilet Compartments
51. 10 22 13 Wire Mesh Partitions
52. 10 22 39 Folding Panel Partitions
Division 13 - SPECIAL CONSTRUCTION
53. 13 34 19 Metal Building Systems
54. 13 48 00 Seismic Protection for Miscellaneous Equipment
Division 21 - FIRE SUPPRESSION
WWYK190023 – Renovate Restrooms, B117 | Page 2 of 4
51. 21 13 17 Dry Pipe Sprinkler System, Fire Protection
Division 22 - PLUMBING
52. 22 05 48.00 20 Mechanical Sound, Vibration, and Seismic Control
Solicitation FA8137-26-R-0030
Division 23 - HVAC
53. 23 01 30.41 HVAC System Cleaning
54. 23 03 00 Basic Mechanical Materials and Methods
55. 23 05 15 Common Piping for HVAC
56. 23 05 48.00 40 Vibration and Seismic Controls for HVAC Piping and Equipment
57. 23 08 01.00 20 Testing Industrial Ventilation Systems
58. 23 09 23.01 LonWorks Direct Digital Control for HVAC and Other Building Control Systems
59. 23 11 25 Facility Gas Piping
60. 23 23 00 Refrigerant Piping
61. 23 25 00 Chemical Treatment of Water for Mechanical Systems
62. 23 31 13.00 40 Metal Ducts
63. 23 34 23.00 40 HVAC Power Ventilators
64. 23 35 00 Overhead Vehicle Tailpipe and Welding Fume Exhaust Removal System(s)
65. 23 36 00.00 40 Air Terminal Units
66. 23 52 00 Heating Boilers
67. 23 54 16 Heating System; Gas-Fired Heaters
68. 23 57 10 Forced Hot Water Heating Systems Using Water and Steam Heat Exchangers
69. 23 64 10 Water Chillers, Vapor Compression Type
70. 23 64 26 Chilled, Chilled-Hot, and Condenser Water Piping Systems
71. 23 65 00 Cooling Towers and Remote Evaporatively-Cooled Condensers
72. 23 70 03 Heating and Utilities Systems, Central Steam
73. 23 81 00 Unitary Air Conditioning Equipment
74. 23 81 23 Computer Room Air Conditioning Units
75. 23 82 01 Warm Air Heating Systems
76. 23 82 16.00 40 Air Coils
77. 23 82 23.00 40 Unit Ventilators
78. 23 82 43.00 40 Electric Duct Heaters
79. 23 82 46.00 40 Electric Unit Heaters
Division 26 - ELECTRICAL
80. 26 05 48.00 10 Seismic Protection for Electrical Equipment
81. 26 08 00 Apparatus Inspection and Testing
82. 26 23 00 Low-Voltage Switchgear
83. 26 28 01.00 10 Coordinated Power System Protection
84. 26 29 23 Variable Frequency Drive Systems Under 600 Volts
85. 26 32 14.00 10 Diesel-Generator Set, Stationary 15-300 KW, Standby Applications
86. 26 36 00.00 10 Automatic Transfer Switch and By-Pass/Isolation Switch
87. 26 41 00 Lightning Protection System
88. 26 42 14.00 10 Cathodic Protection System (Sacrificial Anode)
89. 26 56 00 Exterior Lighting
90. 26 56 20.00 10 Airfield and Heliport Lighting and Visual Navigation Aids
Division 28 - ELECTRONIC SAFETY AND SECURITY
91. 28 31 00.00 10 Fire Detection and Alarm System, Direct Current Loop
92. 28 31 33.00 10 Fire Alarm Reporting System, Radio Type
Division 31 - EARTHWORK
WWYK190023 – Renovate Restrooms, B117 | Page 3 of 4 WWYK190023 – Renovate Restrooms, B117 | Page 4 of 4
93. 31 00 00 Earthwork
Solicitation FA8137-26-R-0030
94. 31 23 06 Excavation, Embankment, and Preparation of Subgrade for Roadways and Parking Lots
95. 31 23 15 Excavation, Filling and Backfilling for Buildings
96. 31 23 16 Excavation, Trenching, and Backfilling for Utilities
Division 32 - EXTERIOR IMPROVEMENTS
Division 33 - UTILITIES
121. 33 11 00 Water Utility Distribution Piping (title per CSI MasterFormat; section not shown on the
Government Table of Contents)
1. 33 40 00 Storm Drainage Utilities
2. 33 71 02 Underground Electrical Distribution Division 40 - PROCESS INTERCONNECTIONS
3. 40 17 26.00 20 Welding Pressure Piping
Total sections requiring confirmation: 124.
The Contractor respectfully notes that the project specifications were not included in the bid files made available prior to the RFI deadline. The Contractor reserves the right to submit additional RFIs upon receipt and review of the applicable specification sections.
97. 32 01 13 Spray Applications, Seal Coats, and Surface Treatments
98. 32 01 14 Asphalt Pavement Sealer
99. 32 01 16 Cold Milling; Asphaltic Concrete
100. 32 01 17 Crack Sealing in Asphalt Concrete Pavements
101. 32 01 17.62 Fabric Reinforcement for Asphalt Concrete Pavements
102. 32 01 18 Joints in Concrete Flatwork
103. 32 01 19 Field Molded Sealants for Sealing Joints in Rigid Pavements
104. 32 01 22 Bituminous Rejuvenation
105. 32 11 11 Asphalt Treated Permeable Base (ATPB) (Drainage Layer)
106. 32 11 23 Aggregate Base Course
107. 32 11 29 Lime-Stabilized Subgrade
108. 32 12 10.1 Bituminous Tack Coat
109. 32 12 10.2 Bituminous Prime Coat
110. 32 12 15 Airfield Pavement, Hot-Mix Asphalt
111. 32 13 11 Airfield Pavement, Portland Cement Concrete
112. 32 13 14 Pavement, Non-Airfield
113. 32 13 73 Joint Sealing in Concrete Pavement Jet-Fuel-Resistant
114. 32 13 74 Joint Sealing in Concrete Pavement Non-Jet-Fuel-Resistant
115. 32 16 13 Concrete Sidewalks and Curbs and Gutters
116. 32 17 23 Pavement Markings
117. 32 31 13 Chain Link Fences and Gates
118. 32 84 24 Irrigation Sprinkler Systems
119. 32 92 19 Seeding
120. 32 92 23 Sodding
S. James Potter -COR
| Specification sections requested to be confirmed NOT applicable: Division 03 - CONCRETE |
| Division 04 - MASONRY |
| Division 05 - METALS |
| Division 06 - WOOD, PLASTICS, AND COMPOSITES |
| Division 07 - THERMAL AND MOISTURE PROTECTION |
| Division 08 - OPENINGS |
| Division 13 - SPECIAL CONSTRUCTION |
| Division 21 - FIRE SUPPRESSION |
| Division 22 - PLUMBING |
| Division 23 - HVAC |
| Division 26 - ELECTRICAL |
| Division 28 - ELECTRONIC SAFETY AND SECURITY |
| Division 31 - EARTHWORK |
| Division 32 - EXTERIOR IMPROVEMENTS |
| Division 40 - PROCESS INTERCONNECTIONS |
| Total sections requiring confirmation: 124. |
| 2026-06-12T07:39:20-0500 | |
| POTTER.STEPHEN.JAMES.1386020503 |
File details come from the government source that posted it. Updated .