This document is a technical specification for concrete reinforcing at Tinker Air Force Base, Oklahoma, effective April 2019 (Section 03 20 00.00 10).
The specification establishes requirements for concrete reinforcement materials, installation, and quality assurance. Required reinforcing steel products include deformed bars conforming to ASTM A615/A615M, ASTM A706/A706M, or ASTM A1035/A1035M; zinc-coated (galvanized) bars per ASTM A767/A767M Class II; and epoxy-coated bars per ASTM A934/A934M. Additional products specified include fabricated bar mats (ASTM A184/A184M), welded wire reinforcement (ASTM A1064/A1064M or ASTM A884/A884M for special applications), mechanical butt-splices with 125 percent minimum yield tensile strength capacity, dowels (ASTM A675/A675M Grade 80 or ASTM A1035/A1035M), wire ties (16 gauge or heavier black annealed steel), bar supports, and synthetic fiber reinforcement (polypropylene with denier less than 100 and 2-inch nominal length). All reinforcing steel furnished must contain no less than 25 percent recycled scrap steel, certified by mill reports prior to installation.
Quality assurance requirements mandate that welders be qualified per AWS D1.4/D1.4M and that steel bar butt-splicers be certified through documented training. Butt-splicing procedures require testing of three test splices per bar size in the presence of the Contracting Officer, with tension testing and stress-strain curve documentation demonstrating compliance with specified strength and deformation limits. Fabrication and placement must follow ACI SP-66 and ACI 318 standards. Installation requirements include placement at locations indicated plus or minus one bar diameter, removal of loose rust and scale before placement, proper lap splicing with staggered joints, and specific support and dowel installation procedures. Submittals requiring government approval include butt-splices, reinforcement shop drawings, qualified welder lists, and steel bar butt-splicer certifications.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ti nker AFB, OK TAFB Techni cal Spr ci f i cat i ons 2019
SECTI ON 03 20 00. 00 10
CONCRETE REI NFORCI NG
PART 1 GENERAL
1. 1 REFERENCES
The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.
AMERI CAN CONCRETE I NSTI TUTE I NTERNATI ONAL ( ACI )
ACI 318 ( 2014; Er r at a 1- 2 2014; Er r at a 3- 5 2015;
Er r at a 6 2016) Bui l di ng Code Requi r ement s f or St r uct ur al Concr et e and Comment ar y
ACI SP- 66 ( 2004) ACI Det ai l i ng Manual
AMERI CAN WELDI NG SOCI ETY ( AWS)
AWS D1. 4/ D1. 4M ( 2011) St r uct ur al Wel di ng Code - Rei nf or ci ng St eel
ASTM I NTERNATI ONAL ( ASTM)
ASTM A1035/ A1035M ( 2016) St andar d Speci f i cat i on f or Def or med and Pl ai n, Low- car bon, Chr omi um, St eel Bar s f or Concr et e Rei nf or cement
ASTM A1064/ A1064M ( 2015) St andar d Speci f i cat i on f or Car bon- St eel Wi r e and Wel ded Wi r e Rei nf or cement , Pl ai n and Def or med, f or Concrete
ASTM A184/ A184M ( 2006; E2011) St andar d Speci f i cat i on f or Fabr i cat ed Def or med St eel Bar Mat s f or Concr et e Rei nf or cement
ASTM A53/ A53M ( 2012) St andar d Speci f i cat i on f or Pi pe, St eel , Bl ack and Hot - Di pped, Zi nc- Coat ed, Wel ded and Seaml ess
ASTM A615/ A615M ( 2015a; E 2015) St andar d Speci f i cat i on f or Def or med and Pl ai n Car bon- St eel Bar s f or Concr et e Rei nf or cement
ASTM A675/ A675M ( 2014) St andar d Speci f i cat i on f or St eel Bar s, Car bon, Hot - Wr ought , Speci al Qual i t y, Mechani cal Pr oper t i es
ASTM A706/ A706M ( 2014) St andar d Speci f i cat i on f or Low- Al l oy St eel Def or med and Pl ai n Bar s f or Concr et e Rei nf or cement
Apr i l 2019 Page 1 SECTI ON 03 20 00. 00 10
ASTM A767/ A767M ( 2009; R 2015) St andar d Speci f i cat i on f or Zi nc- Coat ed ( Gal vani zed) St eel Bar s f or Concr et e Rei nf or cement
ASTM A884/ A884M ( 2014) St andar d Speci f i cat i on f or Epoxy- Coat ed St eel Wi r e and Wel ded Wi r e Reinforcement
ASTM A934/ A934M ( 2013) St andar d Speci f i cat i on f or Epoxy- Coat ed Pr ef abr i cat ed St eel Rei nf or ci ng Bar s
CONCRETE REI NFORCI NG STEEL I NSTI TUTE ( CRSI )
CRSI 10MSP ( 2009; 28t h Ed) Manual of St andar d Pr act i ce
1. 2 SUBMITTALS
Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;
submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00
SUBMI TTAL PROCEDURES:
SD- 01 Pr econst r uct i on Submi t t al s
But t - Spl i ces; G
SD- 02 Shop Dr awi ngs
Rei nf or cement ; G
SD- 03 Pr oduct Dat a
SD- 04 Sampl es
Epoxy- Coat ed Bar s
SD- 07 Cer t i f i cat es
Rei nf or ci ng St eel Qual i f i ed Wel der s Qual i f i cat i on of St eel Bar But t - Spl i cer s
1. 3 QUALI TY ASSURANCE
1. 3. 1 Wel di ng Qual i f i cat i ons
Wel der s ar e r equi r ed t o be qual i f i ed i n accor dance wi t h AWS D1. 4/ D1. 4M.
Per f or m qual i f i cat i on t est at t he wor ksi t e and not i f y t he Cont r act i ng Of f i cer 24 hour s pr i or t o conduct i ng t est s. Speci al wel di ng pr ocedur es and wel der s qual i f i ed by ot her s may be accept ed as per mi t t ed by AWS D1. 4/ D1. 4M. Submi t a l i s t of qual i f i ed wel der s names.
1. 3. 2 Qual i f i cat i on of St eel Bar But t - Spl i cer s
Qual i f i cat i on of st eel bar but t - spl i cer s ar e r equi r ed t o be cer t i f i ed t o have sat i sf act or i l y compl et ed a cour se of i nst r uct i on i n t he pr oposed
Apr i l 2019 Page 2 SECTI ON 03 20 00. 00 10 met hod of but t - spl i c i ng or have sat i sf act or i l y per f or med such wor k wi t hi n t he pr ecedi ng year . Submi t cer t i f i cat es on t he Qual i f i cat i ons of St eel Bar But t - Spl i cer s pr i or t o commenci ng but t - spl i c i ng.
1. 3. 3 Qual i f i cat i on of But t - Spl i c i ng Pr ocedur e
As a condi t i on of appr oval of t he but t - spl i c i ng pr ocedur e, make t hr ee t est but t - spl i ces of st eel bar s of each si ze t o be spl i ced usi ng t he pr oposed but t - spl i c i ng met hod, i n t he pr esence of t he Cont r act i ng Of f i cer . Tensi on t est ed t o dest r uct i on t hese t est but t - spl i ces and unspl i ced bar s of t he same si ze, wi t h st r ess- st r ai n cur ves pl ot t ed f or each t est . Test r esul t s must show t hat t he but t - spl i ces meet t he speci f i ed st r engt h and def or mat i on r equi r ement s i n or der f or t he spl i c i ng pr ocedur e t o be approved.
1. 4 DELI VERY, STORAGE, AND HANDLI NG
St or e r ei nf or cement and accessor i es of f t he gr ound on pl at f or ms, ski ds, or ot her suppor t s.
PART 2 PRODUCTS
2. 1 DOWELS
Pr ovi de dowel s conf or mi ng t o ASTM A675/ A675M, Gr ade 80 or ASTM A1035/ A1035M.
St eel pi pe conf or mi ng t o ASTM A53/ A53M, Schedul e 80, may be used as dowel s pr ovi ded t he ends ar e c l osed wi t h met al or pl ast i c i nser t s or wi t h mor t ar .
2. 2 FABRI CATED BAR MATS
Fabr i cat ed bar mat s conf or mi ng t o ASTM A184/ A184M.
2. 3 REI NFORCI NG STEEL
Rei nf or ci ng st eel of def or med bar s conf or mi ng t o ASTM A615/ A615M, ASTM A706/ A706M, or ASTM A1035/ A1035M gr ades and si zes as i ndi cat ed. Col d dr awn wi r e used f or spi r al r ei nf or cement must conf or m t o ASTM A1064/ A1064M.
Submi t cer t i f i ed copi es of mi l l r epor t s at t est i ng t hat t he r ei nf or ci ng st eel f ur ni shed cont ai ns no l ess t han 25 per cent r ecycl ed scr ap st eel and meet s t he r equi r ement s speci f i ed her ei n, pr i or t o t he i nst al l at i on of r ei nf or ci ng st eel .
2. 3. 1 Zi nc- Coat ed ( Gal vani zed) Bar s
Zi nc- coat ed ( gal vani zed) bar s compl yi ng wi t h t he r equi r ement s of ASTM A767/ A767M, Cl ass I I coat i ng, gal vani zed af t er f abr i cat i on.
2. 3. 2 Epoxy- Coat ed Bar s
Epoxy- coat ed st eel bar s compl yi ng wi t h t he r equi r ement s of ASTM A934/ A934M, i ncl udi ng wr i t t en cer t i f i cat i ons f or coat i ng mat er i al and coat ed bar s, sampl e of coat i ng mat er i al , and 1. 5 pounds of pat chi ng mat er i al .
2. 3. 3 Mechani cal But t - Spl i ces
Mechani cal but t spl i ces must be an appr oved exot her mi c, t hr eaded coupl i ng, Apr i l 2019 Page 3 SECTI ON 03 20 00. 00 10 swaged sl eeve or ot her posi t i ve connect i ng t ype, and devel op 125 per cent of t he speci f i ed mi ni mum yi el d t ensi l e st r engt h of t he spl i ced bar s or of t he smal l er bar i n t r ansi t i on spl i ces. I n addi t i on t o t hi s st r engt h r equi r ement , t he addi t i onal def or mat i on of number 14 and smal l er bar s due t o s l i ppage or ot her movement wi t hi n t he spl i ce s l eeve cannot exceed 0. 015 i nches ( uni t st r ai n 0. 0015 i nches/ i nch) beyond t he el ongat i on of an unspl i ced bar based upon a 10 i nch gage l engt h spanni ng t he ext r emi t i es of t he s l eeve at a st r ess of 30, 000 psi . The addi t i onal def or mat i on of number 18 bar s must not exceed 0. 03 i nches ( uni t st r ai n 0. 003 i nches/ i nch) beyond t he el ongat i on of an unspl i ced bar based upon a 10 i nch gage l engt h spanni ng t he ext r emi t i es of t he s l eeve at a st r ess of 30, 000 psi .
Det er mi ne t he amount of t he addi t i onal def or mat i on f r om t he st r ess- st r ai n cur ves of t he unspl i ced and spl i ced bar s t est ed as r equi r ed i n par agr aph QUALI FI CATI ON OF BUTT- SPLI CI NG PROCEDURE f or qual i f i cat i on of t he but t - spl i c i ng pr ocedur e.
2. 4 WELDED WI RE REI NFORCI NG
Wel ded wi r e r ei nf or ci ng conf or mi ng t o ASTM A1064/ A1064M. When di r ect ed by t he Cont r act i ng Of f i cer f or speci al appl i cat i ons, use wel ded wi r e r ei nf or ci ng conf or mi ng t o ASTM A884/ A884M.
2. 5 WI RE TI ES
Use wi r e t i es t hat ar e 16 gauge or heavi er bl ack anneal ed st eel wi r e.
Ti es f or epoxy- coat ed bar s must be vi nyl - coat ed or epoxy- coat ed. Use zi nc- coat ed t i es f or z i nc- coat ed bar s.
2. 6 SUPPORTS
Desi gn bar suppor t s f or f or med sur f aces i n accor dance wi t h CRSI 10MSP and f abr i cat e of st eel or pr ecast concr et e bl ocks. Pr ovi de pr ecast concr et e bl ocks wi t h wi r e t i es and not l ess t han 4 i nches squar e when suppor t i ng r ei nf or cement on gr ound. Pr ecast concr et e bl ock must have compr essi ve st r engt h equal t o t hat of t he sur r oundi ng concr et e. Coat st eel suppor t s f or coat ed or gal vani zed bar s wi t h el ect r i cal l y compat i bl e mat er i al f or a di st ance of at l east 2 i nches beyond t he poi nt of cont act wi t h t he bar .
Wher e concr et e f or med sur f aces wi l l be exposed t o weat her or wher e sur f aces ar e t o be pai nt ed, use gal vani zed, pl ast i c pr ot ect ed or st ai nl ess st eel suppor t s wi t hi n 1/ 2 i nch of concr et e sur f ace. Concr et e suppor t s used i n concr et e exposed t o v i ew must have t he same col or and t ext ur e as t he f i ni sh sur f ace. For s l abs on gr ade and t oppi ng sl abs on st eel deck, suppor t s use pr ecast concr et e bl ocks, pl ast i c coat ed st eel f abr i cat ed wi t h bear i ng pl at es, or speci f i cal l y desi gned wi r e- f abr i c suppor t s f abr i cat ed of pl ast i c.
2. 7 SYNTHETI C FI BER REI NFORCEMENT
Pol ypr opyl ene synt het i c f i ber wi t h a deni er l ess t han 100 and a nomi nal f i ber l engt h of 2 i nches.
PART 3 EXECUTI ON
3. 1 REINFORCEMENT
Fabr i cat e and pl ace r ei nf or cement st eel and accessor i es as speci f i ed, as i ndi cat ed, and as shown on appr oved shop dr awi ngs. Fabr i cat i on and pl acement det ai l s of st eel and accessor i es not speci f i ed or shown must be i n accor dance wi t h ACI SP- 66 and ACI 318. Col d bend r ei nf or cement unl ess
Apr i l 2019 Page 4 SECTI ON 03 20 00. 00 10 ot her wi se aut hor i zed. Bendi ng may be accompl i shed i n t he f i el d or at t he mi l l . Mi l l bend zi nc- coat ed and epoxy- coat ed bar s pr i or t o coat i ng.
Bend al l st eel col d unl ess aut hor i zed. Do not bend bar s af t er embedment i n concr et e. Pl ace saf et y caps on al l exposed ends of ver t i cal concr et e r ei nf or cement bar s t hat pose a danger t o l i f e saf et y. Face wi r e t i e ends away f r om t he f or ms. Submi t det ai l dr awi ngs showi ng r ei nf or ci ng st eel pl acement , schedul es, s i zes, gr ades, and spl i c i ng and bendi ng det ai l s.
Show suppor t det ai l s i ncl udi ng t ypes, s i zes and spaci ng.
3. 1. 1 Placement
Rei nf or cement must be f r ee f r om l oose r ust and scal e, di r t , oi l , or ot her del et er i ous coat i ng t hat coul d r educe bond wi t h t he concr et e. Pl ace r ei nf or cement i n accor dance wi t h ACI 318 at l ocat i ons i ndi cat ed pl us or mi nus one bar di amet er . Do not cont i nue r ei nf or cement t hr ough expansi on j oi nt s and pl ace as i ndi cat ed t hr ough const r uct i on or cont r act i on j oi nt s.
Cover wi t h concr et e cover age as i ndi cat ed or as r equi r ed by ACI 318. I f bar s ar e moved mor e t han one bar di amet er t o avoi d i nt er f er ence wi t h ot her r ei nf or cement , condui t s or embedded i t ems, t he r esul t i ng ar r angement of bar s, i ncl udi ng addi t i onal bar s r equi r ed t o meet st r uct ur al r equi r ement s, r equi r es appr oval bef or e concr et e i s pl aced.
3. 2 WELDED- WI RE REI NFORCEMENT PLACEMENT
Pl ace wel ded- wi r e r ei nf or cement i n s l abs as i ndi cat ed. Rei nf or cement pl aced i n s l abs on gr ade must be cont i nuous bet ween expansi on, const r uct i on, and cont r act i on j oi nt s. Rei nf or cement pl acement at j oi nt s must be as i ndi cat ed.
Pl ace l ap spl i ces i n such a way t hat t he over l apped ar ea equal s t he di st ance bet ween t he out er most cr osswi r es pl us 2 i nches. St agger l aps t o avoi d cont i nuous l aps i n ei t her di r ect i on. Wi r e or c l i p t oget her r ei nf or cement at l aps at i nt er val s not t o exceed 4 f eet . Posi t i on r ei nf or cement by t he use of suppor t s.
3. 3 DOWEL I NSTALLATI ON
I nst al l dowel s i n s l abs on gr ade at l ocat i ons i ndi cat ed and at r i ght angl es t o j oi nt bei ng dowel ed. Accur at el y posi t i on and al i gn dowel s par al l el t o t he f i ni shed concr et e sur f ace bef or e concr et e pl acement .
Ri gi dl y suppor t dowel s dur i ng concr et e pl acement . Coat one end of dowel s wi t h a bond br eaker .
- - End of Sect i on - -
Apr i l 2019 Page 5 SECTI ON 03 20 00. 00 10