08 14 00.pdf
PDF 26 KB Posted
- Solicitation number
- FA813726R0030
About this file
This is a technical specification document for wood doors at Tinker Air Force Base, Oklahoma, issued in April 2019 under Section 08 14 00 of the construction specifications.
The specification establishes requirements for flush doors, acoustical doors, and fire-rated doors that must conform to ANSI/WDMA standards (I.S.1A for flush doors and I.S.6A for stile and rail doors). Interior flush doors must feature staved lumber, particleboard, or agrifiber cores with a minimum 45 percent recycled content and sound grade hardwood or hardboard faces for painted finishes. Doors must be free of urea-formaldehyde resins and include certification of indoor air quality for particleboard and agrifiber cores. Acoustical doors must achieve a Sound Transmission Class rating of 35 per ASTM E90. Fire doors must comply with UL 10B, ASTM E2226, or NFPA 252 standards with permanent metal labels affixed to the hinge edge. Finishes may include field painting, factory-applied WDMA system finishes (TR-8, TR-2, or TR-4) utilizing water-based stains and UV protection, or plastic laminate (ANSI/NEMA LD 3) at minimum 0.050 inch thickness. Water-resistant sealer must be applied to all doors, with additional treatment required for restrooms, janitor closets, and exterior doors. Installation requires specified clearances (1/16 inch minimum to 1/8 inch maximum at sides and top, 3/16 inch minimum to 1/4 inch maximum over thresholds), edge sealing, and compliance with NFPA 80 and NFPA 105 for fire and smoke doors. Submittals requiring government approval include shop drawings, product data, door finish color samples (minimum three), sound transmission class ratings, fire resistance ratings, test reports for cycle-slam and hinge loading resistance, certified sustainably harvested wood certification, and indoor air quality certifications.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ti nker AFB, OK TAFB Techni cal Spr ci f i cat i ons 2019
SECTI ON 08 14 00
WOOD DOORS
PART 1 GENERAL
1. 1 REFERENCES
The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o i n t he t ext by t he basi c desi gnat i on onl y.
AMERI CAN FOREST FOUNDATI ON ( AFF)
ATFS STANDARDS ( 2015) Amer i can Tr ee Far m Syst em St andar ds of Sust ai nabi l i t y 2015- 2020
ARCHI TECTURAL WOODWORK I NSTI TUTE ( AWI )
AWI AWS ( 2nd Edi t i on) Ar chi t ect ur al Woodwor k Standards
ASTM I NTERNATI ONAL ( ASTM)
ASTM E2226 ( 2015a) St andar d Pr act i ce f or Appl i cat i on of Hose St r eam
ASTM E283 ( 2004; R 2012) Det er mi ni ng t he Rat e of Ai r Leakage Thr ough Ext er i or Wi ndows, Cur t ai n Wal l s, and Door s Under Speci f i ed Pr essur e Di f f er ences Acr oss t he Speci men
ASTM E90 ( 2009) St andar d Test Met hod f or Labor at or y Measur ement of Ai r bor ne Sound Tr ansmi ssi on Loss of Bui l di ng Par t i t i ons and El ement s
CALI FORNI A AI R RESOURCES BOARD ( CARB)
CARB 93120 ( 2007) Ai r bor ne Toxi c Cont r ol Measur e ( ATCM) t o Reduce For mal dehyde Emi ssi ons f r om Composi t e Wood Pr oduct s
CALI FORNI A DEPARTMENT OF PUBLI C HEALTH ( CDPH)
CDPH SECTI ON 01350 ( 2004; Add 2004- 01) St andar d Pr act i ce f or t he Test i ng Of Vol at i l e Or gani c Emi ssi ons f r om Var i ous Sour ces Usi ng Smal l - Scal e Envi r onment al Chamber s
CSA GROUP ( CSA)
CSA Z809- 08 ( R2013) Sust ai nabl e For est Management
FOREST STEWARDSHI P COUNCI L ( FSC)
FSC STD 01 001 ( 2000) Pr i nci pl es and Cr i t er i a f or For est
Apr i l 2019 Page 1 SECTI ON 08 14 00
Stewardship
NATI ONAL ELECTRI CAL MANUFACTURERS ASSOCI ATI ON ( NEMA)
ANSI / NEMA LD 3 ( 2005) St andar d f or Hi gh- Pr essur e Decor at i ve Lami nat es
NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)
NFPA 105 ( 2016) St andar d f or I nst al l at i on of Smoke Door Assembl i es and Ot her Openi ng Protectives
NFPA 252 ( 2017) St andar d Met hods of Fi r e Test s of Door Assembl i es
NFPA 80 ( 2016) St andar d f or Fi r e Door s and Ot her Openi ng Pr ot ect i ves
PROGRAMME FOR ENDORSEMENT OF FOREST CERTI FI CATI ON ( PEFC)
PEFC ST 2002: 2013 ( 2015) PEFC I nt er nat i onal St andar d Chai n of Cust ody of For est Based Pr oduct s Requirements
SUSTAI NABLE FOREST I NI TI ATI VE ( SFI )
SFI 2015- 2019 ( 2015) St andar ds, Rul es f or Label Use, Pr ocedur es and Gui dance
UNDERWRI TERS LABORATORI ES ( UL)
UL 10B ( 2008; Repr i nt Feb 2015) Fi r e Test s of Door Assembl i es
WI NDOW AND DOOR MANUFACTURERS ASSOCI ATI ON ( WDMA)
ANSI / WDMA I . S. 1A ( 2013) I nt er i or Ar chi t ect ur al Wood Fl ush Doors
ANSI / WDMA I . S. 6A ( 2013) I nt er i or Ar chi t ect ur al St i l e and Rai l Door s
1. 2 SUBMITTALS
Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;
submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00
SUBMI TTAL PROCEDURES:
SD- 02 Shop Dr awi ngs
Door s; G
Submi t dr awi ngs or cat al og dat a showi ng each t ype of door uni t .
I ndi cat e wi t hi n dr awi ngs and dat a t he door t ypes and const r uct i on, s i zes, t hi ckness, door l ouver s, and gl azi ng, .
SD- 03 Pr oduct Dat a
Apr i l 2019 Page 2 SECTI ON 08 14 00
Door s; G
Accessories
Wat er - r esi st ant Seal er
Sampl e War r ant y
Sound Tr ansmi ssi on Cl ass Rat i ng; G
Fi r e Resi st ance Rat i ng; G
SD- 04 Sampl es
Door Fi ni sh Col or s; G
Submi t a mi ni mum of t hr ee col or sel ect i on sampl es f or sel ect i on by t he Cont r act i ng Of f i cer .
SD- 06 Test Repor t s
Cycle-Slam
Hi nge Loadi ng Resi st ance
Submi t cycl e- sl am t est r epor t f or door s t est ed i n accor dance wi t h ANSI / WDMA I . S. 1A, and hi nge l oadi ng r esi st ance t est r epor t f or door s t est ed i n accor dance wi t h ANSI / WDMA I . S. 6A.
SD- 07 Cer t i f i cat es
Cer t i f i cat es of Gr ade
Cer t i f i ed Sust ai nabl y Har vest ed Wood; G
I ndoor Ai r Qual i t y: G
SD- 11 Cl oseout Submi t t al s
Warranty
1. 3 DELI VERY, STORAGE, AND HANDLI NG
Del i ver door s t o t he s i t e i n an undamaged condi t i on and pr ot ect agai nst damage and dampness. St ack door s f l at under cover . Suppor t on bl ocki ng, a mi ni mum of 4 i nch t hi ck, l ocat ed at each end and at t he mi dpoi nt of t he door . St or e door s i n a wel l - vent i l at ed bui l di ng so t hat t hey wi l l not be exposed t o excessi ve moi st ur e, heat , dr yness, di r ect sunl i ght , or ext r eme changes of t emper at ur e and humi di t y. Do not st or e i n a bui l di ng under const r uct i on unt i l concr et e, masonr y wor k, and pl ast er ar e dr y. Repl ace def ect i ve or damaged door s wi t h new ones.
1. 4 WARRANTY
War r ant door s f r ee of def ect s as set f or t h i n t he door manuf act ur er ' s
Apr i l 2019 Page 3 SECTI ON 08 14 00 st andar d door war r ant y.
PART 2 PRODUCTS
2. 1 DOORS
Pr ovi de door s of t he t ypes, s i zes, and desi gns i ndi cat ed f r ee of ur ea- f or mal dehyde r esi ns.
2. 1. 1 Fl ush Door s
Conf or m t o ANSI / WDMA I . S. 1A f or f l ush door s. Pr ovi de hol l ow cor e door s wi t h l ock bl ocks and 1 i nch mi ni mum t hi ckness hi nge st i l e. Har dwood st i l e edge bands of door s r ecei ves a nat ur al f i ni sh, compat i bl e wi t h f ace veneer . Pr ovi de mi l l opt i on f or st i l e edge of door s schedul ed t o be pai nt ed. No vi s i bl e f i nger j oi nt s wi l l be accept ed i n st i l e edge bands.
When used, l ocat e f i nger - j oi nt s under har dwar e.
2. 1. 1. 1 I nt er i or Fl ush Door s
Pr ovi de st aved l umber , par t i c l eboar d, or agr i f i ber cor e, Type I I f l ush door s conf or mi ng t o ANSI / WDMA I . S. 1A wi t h f aces of sound gr ade har dwood or har dboar d f or pai nt ed f i ni sh . Har dwood veneer s must be pl ai n s l i ced .
Door cor es must have a mi ni mum r ecycl ed cont ent of 45 per cent . Pr ovi de dat a i dent i f y i ng per cent age of r ecycl ed cont ent f or door cor es. Pr ovi de cer t i f i cat i on of i ndoor ai r qual i t y f or par t i c l eboar d and agr i f i ber door cores.
2. 1. 2 Acoust i cal Door s
ANSI / WDMA I . S. 1A, sol i d cor e, const r uct ed t o pr ovi de Sound Tr ansmi ssi on Cl ass r at i ng of 35 when t est ed i n accor dance wi t h ASTM E90.
2. 1. 3 Fi r e Door s
Pr ovi de door s speci f i ed or i ndi cat ed t o have a f i r e r esi st ance r at i ng conf or mi ng t o t he r equi r ement s of UL 10B, ASTM E2226, or NFPA 252 f or t he c l ass of door i ndi cat ed. Af f i x a per manent met al l abel wi t h r ai sed or i nci sed mar ki ngs i ndi cat i ng t est i ng agency' s name and appr oved hour l y f i r e r at i ng t o hi nge edge of each door .
2. 2 ACCESSORIES
2. 2. 1 Door Li ght Openi ngs
Pr ovi de gl azed openi ngs wi t h t he manuf act ur er ' s st andar d wood mol di ngs.
Pr ovi de mol di ngs f or door s t o r ecei ve nat ur al f i ni sh of t he same wood speci es and col or as t he wood f ace veneer s.
2. 2. 2 Addi t i onal Har dwar e Rei nf or cement
Pr ovi de t he mi ni mum l ock bl ocks t o secur e t he speci f i ed har dwar e. The measur ement of t op, bot t om, and i nt er medi at e r ai l bl ocks ar e a mi ni mum 125 mm 5 i nch by f ul l cor e wi dt h. Compl y wi t h t he manuf act ur er ' s l abel i ng r equi r ement s f or r ei nf or cement bl ocki ng, but not mi ner al mat er i al s i mi l ar t o t he cor e.
Apr i l 2019 Page 4 SECTI ON 08 14 00
2. 3 FABRICATION
2. 3. 1 Marking
St amp each door wi t h a br and, st amp, or ot her i dent i f y i ng mar k i ndi cat i ng qual i t y and const r uct i on of t he door .
2. 3. 2 Qual i t y and Const r uct i on
I dent i f y t he st andar d on whi ch t he const r uct i on of t he door was based, and i dent i f y door s havi ng a Type I gl ue bond.
2. 3. 3 Pr eser vat i ve Tr eat ment
Tr eat door s schedul ed f or r est r ooms, j ani t or c l oset s and ot her possi bl e wet l ocat i ons i ncl udi ng ext er i or door s wi t h a wat er - r epel l ent pr eser vat i ve t r eat ment and so mar ket ed at t he manuf act ur er ' s pl ant .
2. 3. 4 Adhesi ves and Bonds
ANSI / WDMA I . S. 1A. Use Type I bond f or ext er i or door s and Type I I bond f or i nt er i or door s. Pr ovi de a nonst ai ni ng adhesi ve on door s wi t h a nat ur al finish.
2. 3. 5 Prefitting
Pr ovi de f act or y f i ni shed and f act or y pr ef i t t ed door s f or t he speci f i ed har dwar e, door f r ame and door - swi ng i ndi cat ed. Machi ne and si ze door s at t he f act or y by t he door manuf act ur er i n accor dance wi t h t he st andar ds under whi ch t he door s ar e pr oduced and manuf act ur ed. The wor k i ncl udes si z i ng, bevel i ng edges, mor t i s i ng, and dr i l l i ng f or har dwar e and pr ovi di ng necessar y beaded openi ngs f or gl ass and l ouver s. Pr ovi de t he door manuf act ur er wi t h t he necessar y har dwar e sampl es, and f r ame and har dwar e schedul es t o coor di nat e t he wor k.
2. 3. 6 Finishes
2. 3. 6. 1 Fi el d Pai nt i ng
Fact or y pr i me or seal door s, and f i el d pai nt .
2. 3. 6. 2 Fact or y Fi ni sh
Pr ovi de door s f i ni shed at t he f act or y by t he door manuf act ur er as f ol l ows:
WDMA Syst em TR- 8 ( UV cur ed acr yl at ed pol yest er / ur et hane) or TR- 2 ( cat al yzed l acquer ) or TR- 4 ( conver si on var ni sh) f act or y f i ni sh syst ems t hat ut i l i ze wat er - based st ai ns and f i ni shes wi t h ul t r avi ol et UV pr ot ect i on. The coat i ng i s AWI AWS pr emi um, medi um r ubbed sheen, c l osed gr ai n ef f ect . Use st ai n when r equi r ed t o pr oduce t he f i ni sh speci f i ed f or col or . Seal edges, cut out s, t r i m, and wood accessor i es, and appl y t wo coat s of f i ni sh compat i bl e wi t h t he door f ace f i ni sh. Touch- up f i ni shes t hat ar e scr at ched or mar r ed, or wher e exposed f ast ener hol es ar e f i l l ed, i n accor dance wi t h t he door manuf act ur er ' s i nst r uct i ons. Mat ch col or and sheen of f act or y f i ni sh usi ng mat er i al s compat i bl e f or f i el d appl i cat i on.
2. 3. 6. 3 Pl ast i c Lami nat e Fi ni sh
Fact or y appl i ed, ANSI / NEMA LD 3, Gener al or Speci f i c pur pose t ype, 0. 050 i nch mi ni mum t hi ckness. Gl ue l ami nat ed pl ast i c f or hol l ow cor e door s t o
Apr i l 2019 Page 5 SECTI ON 08 14 00 wood veneer , pl ywood, or har dboar d backi ng t o f or m door panel . Pr ovi de a combi ned t hi ckness of l ami nat e sheet and backi ng of 0. 10 i nch mi ni mum.
2. 3. 6. 4 Color
Pr ovi de door f i ni sh col or s as i ndi cat ed on t he dr awi ngs.
2. 3. 7 Wat er - Resi st ant Seal er
Pr ovi de manuf act ur er ' s st andar d wat er - r esi st ant seal er compat i bl e wi t h t he speci f i ed f i ni shes.
2. 4 SOURCE QUALI TY CONTROL
Meet or exceed t he f ol l owi ng mi ni mum per f or mance cr i t er i a of st i l es of " B" and " C" l abel f i r e door s ut i l i z i ng st andar d mor t i se l eaf hi nges:
a. Cycl e- sl am: St andar d Dut y Door s: 250, 000 cycl es wi t h no l oose hi nge scr ews or ot her v i s i bl e s i gns of f ai l ur e when t est ed i n accor dance wi t h t he r equi r ement s of ANSI / WDMA I . S. 1A. Heavy Dut y Door s: 500, 000 cycl es wi t h no l oose hi nge scr ews or ot her v i s i bl e s i gns of f ai l ur e when t est ed i n accor dance wi t h t he r equi r ement s of ANSI / WDMA I . S. 1A
b. Hi nge l oadi ng r esi st ance: Aver ages of t en t est sampl es not l ess t han St andar d Dut y door s: 400 pounds f or ce, Heavy Dut y door s: 475 pounds f or ce, Ext r a Heavy Dut y door s: 550 pounds f or ce when t est ed f or di r ect scr ew wi t hdr awal i n accor dance wi t h ANSI / WDMA I . S. 6A usi ng a No. 12, 1- 1/ 4 i nch l ong, st eel , f ul l y t hr eaded wood scr ew. Dr i l l 5/ 32 i nch pi l ot hol e, use 1- 1/ 2 i nch openi ng ar ound scr ew f or bear i ng sur f ace, and engage scr ew f ul l , except f or l ast 1/ 8 i nch. Do not use a st eel pl at e t o r ei nf or ce scr ew ar ea.
PART 3 EXECUTI ON
3. 1 INSTALLATION
Do not i nst al l bui l di ng const r uct i on mat er i al s t hat show vi sual evi dence of bi ol ogi cal gr owt h.
Bef or e i nst al l at i on, seal t op and bot t om edges of door s wi t h t he appr oved wat er - r esi st ant seal er . Seal cut s made on t he j ob i mmedi at el y af t er cut t i ng usi ng appr oved wat er - r esi st ant seal er . Fi t , t r i m, and hang door s wi t h a 1/ 16 i nch mi ni mum, 1/ 8 i nch maxi mum cl ear ance at s i des and t op, and a 3/ 16 i nch mi ni mum, 1/ 4 i nch maxi mum cl ear ance over t hr eshol ds. Pr ovi de 3/ 8 i nch mi ni mum, 7/ 16 i nch maxi mum cl ear ance at bot t om wher e no t hr eshol d occur s. Bevel edges of door s at t he r at e of 1/ 8 i nch i n 2 i nch. Door war p must not exceed 1/ 4 i nch when measur ed i n accor dance wi t h
ANSI / WDMA I . S. 1A.
3. 1. 1 Fi r e and Smoke Door s
I nst al l f i r e door s i n accor dance wi t h NFPA 80. I nst al l smoke door s i n accor dance wi t h NFPA 105. Do not pai nt over l abel s.
- - End of Sect i on - -
Apr i l 2019 Page 6 SECTI ON 08 14 00
File details come from the government source that posted it. Updated .