Attch. 08 IBWC SBIWTP - Asset Maintenance Schedule.xlsx

XLSX spreadsheet 237 KB Posted

Attached to
Operation & Maintenance of the South Bay Wastewater Treatment Plant Federal contract opportunity
Solicitation number
FY26OMSBIWTP
Issued by
International Boundary and Water Commission U.S.-Mexico

View the file

Other files for this federal contract opportunity

Other files attached to Operation & Maintenance of the South Bay Wastewater Treatment Plant, newest first.
File Type Posted
191BWC26R0001 0008.pdf PDF
191BWC26R0001 0007.pdf PDF
191BWC26R0001 0006.pdf PDF
191BWC26R0001 0005.pdf PDF
FY26 SBIWTP OM PWS_Amended 16 Dec 2025 (2).pdf PDF
Request For Information_ Final for Solicitation Posting (1).xlsx XLSX spreadsheet
191BWC26R0001 0004.pdf PDF
Attch. 20 Wage Determinations CA202100001CA20240001 07.26.2024.pdf PDF
191BWC26R0001 0003.pdf PDF
Site Visit SB Exp-ENG 11.7.2025_rev.pptx PPTX presentation
Attch. 29 CUI_SBIWTP PDB Early Work Package 1C Replace in Kind.pdf PDF
Attch. 28 SBIWTP PDB Expansion SOW Section 01.31.83.01.pdf PDF
Attch. 26 Emergency Response Plan.pdf PDF
Attch. 25 Tijuana wastewater flow diagram Oct 2025.pdf PDF
Attch. 24 2025 IBWC Risk Assessment Final.pdf PDF
Attch. 21 IBWC Spill and Transboundary Plan 2021.pdf PDF
Request For Information_ Final for Solicitation Posting.xlsx XLSX spreadsheet
Attch. 22 USIBWC SDFO Org Chart.pdf PDF
Attch. 14 SBIWTP SSP 042020.pdf PDF
Attch. 10 Updated September October 2025 Chemical Dosage.pdf PDF
Attch. 04A CDO-R9-2025-0139.pdf PDF
FY26 SBIWTP OM PWS_Amended 16 Dec 2025.pdf PDF
Attch. 27 SBIWTP OM Contract PWS 2020.pdf PDF
Attch. 23 IBWC SBIWTP - Capital Improvement Plan (2025 - 2029).pdf PDF
Attch. 22A 2019 Contractor OrgChart.pdf PDF
FY26 SBIWTP OM PWS_Final.pdf PDF
191BWC26R0001 002.pdf PDF
191BWC26R0001 0001.pdf PDF
191BWC26R0001 OM Services SBIWTP.pdf PDF
Attch. 19 SOO_V2_06192018.pdf PDF
Attch. 20 Wage Determinations CA20240001 07.26.2024.pdf PDF
Attch. 10 Monthly Chemical Dosage March 2024 to March 2025.pdf PDF
Attch. 06 IBWC SBIWTP Asset Registry 2024.xlsx XLSX spreadsheet
Attch. 11 Canyon Collector Daily Inspection template- MAR 2025.xlsx XLSX spreadsheet
Attch. 13 SBIWTP O&M Manual.pdf PDF
Attch. 04 NPDES Permit Order R9-2023-0009.pdf PDF
Attch. 14 SBIWTP SSP 042020.pdf PDF
Attch. 01 SOM SUBMITTAL REGISTER SBIWTP O&M 2026.xlsx XLSX spreadsheet
Attch. 03 RPM- Table 2026.xlsx XLSX spreadsheet
Attch. 12 2024 NPDES ANNUAL BIOSOLIDS.pdf PDF
Attch. 16 Plans Drawings.docx DOCX document
Attch. 18 NIST.FIPS.199.pdf PDF
Attch. 09 SBIWTP Capital Project List as of April 2025.pdf PDF
Attch. 17 SBIWTP Map.pdf PDF
Attch. 15 NIST.SP.800-171r3.pdf PDF
Attch. 07 Condition Assessment Report Jan 2024.pdf PDF
Attch. 05 List-of-Permits.docx DOCX document
Attch. 02 FY26 SBIWTP O&M QASP.doc DOC document
Show all 48

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PM Details w Equipment Routes

DepartmentPM SchedulePreventative Maint. (PM) DescriptionIntervalWork Order TypeRouteRoute Eq. CountRoute EquipmentEquipment DescriptionTask InstructionsCrewTrade
WWTPIBW-PM-0004PM - MONTHLY COMPRESSOR FILTER INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-00048E-00001725COMPRESSOR, AIR, BLOWER BUILDING PABCMP, Quincy Model QT5[ ] Inspect and clean/replace Air Filters (If Needed).IBW-MAINTVMECH
WWTPIBW-PM-0004PM - MONTHLY COMPRESSOR FILTER INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-00048E-00001038COMPRESSOR UNIT, AIR, PURGE, SP 02600-PURGE1, Campbell Hausfeld, TF061903AV[ ] Inspect and clean/replace Air Filters (If Needed).IBW-MAINTVMECH
WWTPIBW-PM-0004PM - MONTHLY COMPRESSOR FILTER INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-00048E-00000549COMPRESSOR, 5 HP, MAINTENANCE GARAGE 02610-SHOP-COMP1[ ] Inspect and clean/replace Air Filters (If Needed).IBW-MAINTVMECH
WWTPIBW-PM-0004PM - MONTHLY COMPRESSOR FILTER INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-00048E-00001541COMPRESSOR, AIR, PORTABLE, INGERSOLL-RAND 03801-AIR-PORTABLE[ ] Inspect and clean/replace Air Filters (If Needed).IBW-MAINTVMECH
WWTPIBW-PM-0004PM - MONTHLY COMPRESSOR FILTER INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-00048E-00001296COMPRESSOR 2, FILL, TANK, HYDROPNEUMATIC, NPW 01345-HTFC2[ ] Inspect and clean/replace Air Filters (If Needed).IBW-MAINTVMECH
WWTPIBW-PM-0004PM - MONTHLY COMPRESSOR FILTER INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-00048E-00001295COMPRESSOR 1, FILL, TANK, HYDROPNEUMATIC, NPW 01345-HTFC1[ ] Inspect and clean/replace Air Filters (If Needed).IBW-MAINTVMECH
WWTPIBW-PM-0004PM - MONTHLY COMPRESSOR FILTER INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-00048E-00001867Compressor, Air, Maint Bldg, Polar Air[ ] Inspect and clean/replace Air Filters (If Needed).IBW-MAINTVMECH
WWTPIBW-PM-0004PM - MONTHLY COMPRESSOR FILTER INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-00048E-00001858Compressor, Air, Speedaire, 4B250A, Grit Gallery[ ] Inspect and clean/replace Air Filters (If Needed).IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00001003ACTUATOR, GATE 2, EFFLUENT, SECONDARY, EBS 01503-MV-SEG1O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation [ ] Check Gear Case Oil Level - Fill If Necessary [ ] Inspect Concrete, Pedestal And Yoke For Cracks Or Deterioration.

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00000984GATE 1, SLUICE, INLET, WEIR, OVERFLOW, EDS, 72" (ME14) 01540-EDS-ME14O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00000990GATE, SLUICE, INLET, DISTRIBUTION, EFFLUENT, 96" (ME11) 01540-EDS-ME11O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00000983GATE 2, SLUICE, INLET, DISSIPATION, ENERGY, 144" (ME13) 01540-EDS-ME13O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00000986GATE, SLUICE, INLET, SBWRT, EDS, 72" (FUTURE) (ME18) 01540-EDS-ME18O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00000999ACTUATOR, GATE 1, EFFLUENT, BLENDED, EBS 01504-MV-BEG1O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00000998GATE 1, EFFLUENT, BLENDED, EBS 01504-G-SLIDE-BEG1O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00001095GATE, SLUICE, 96", JB-1 00100-GATE-JB1-96O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00001002GATE 2, EFFLUENT, SECONDARY, EBS 01503-G-SLIDE-SEG1O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00000982GATE 1, SLUICE, INLET, DISSIPATION, ENERGY, 144" (ME12) 01540-EDS-ME12O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00000991GATE, SLUICE, RE-USE, MEXICO, EDS, (FUTURE) (ME17) 01540-EDS-ME17O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00001001GATE 1, BYPASS, EFFLUENT, PRIMARY, EBS 01502-G-SLIDE-PEBG1O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00000985GATE 2, SLUICE, INLET, WEIR, OVERFLOW, EDS, 72" (ME15) 01540-EDS-ME15O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0027PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-002714E-00001000ACTUATOR, GATE 1, BYPASS, EFFLUENT, PRIMARY, EBS 01502-MV-PEBG1O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7

[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.

**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.

[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:

Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.

[ ] Grease the motor with one of the following:

Shell Oil Dolium R Chevron SRI NLGI #2

**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0051PM - 6-MONTH USST SLUDGE MIXING PUMPS 1A-1C O&M SERVICE6 MonthsPreventive maintenanceIBW-ROUTE-00513E-00001469PUMP 1A, MIXING, SLUDGE, USST 02211-SMP1AO&M manual - Area 7 USST. Refer to pdf pages 54-55; O&M page 5.7-2 to 5.7-3

[ ] Regrease sludge mixing pump bearings with one of the following:

Mobil DTE Medium Exxon Teresstic 68 Shell Tellus 68

The hearing housing is equipped with a breather cap on top and a sight gauge on the side. Oil is added by removing the breather and filling the housing until the oil level is about half way up the sight gauge.

Do not overfill the bearing housing as foaming and high bearing temperatures may result.

[ ] Regrease sludge mixing pump motor bearings with one of the following:

Sun Oil Multi-Purpose #2EP Mobil Mobilux #2EP Shell Alvania #2EP Texaco Multipak #2EP Exxon Lidok #2EP

Motors can be regreased by stopping the motor, removing drain plug and pumping new grease into fill hole. Use a low pressure grease gun and avoid overgreasing. Run motor with drain plug removed until excess grease has been discharged (minimum 10 minutes). Stop motor and replace drain plug.

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0051PM - 6-MONTH USST SLUDGE MIXING PUMPS 1A-1C O&M SERVICE6 MonthsPreventive maintenanceIBW-ROUTE-00513E-00001471PUMP 1B, MIXING, SLUDGE, USST 02212-SMP1BO&M manual - Area 7 USST. Refer to pdf pages 54-55; O&M page 5.7-2 to 5.7-3

[ ] Regrease sludge mixing pump bearings with one of the following:

Mobil DTE Medium Exxon Teresstic 68 Shell Tellus 68

The hearing housing is equipped with a breather cap on top and a sight gauge on the side. Oil is added by removing the breather and filling the housing until the oil level is about half way up the sight gauge.

Do not overfill the bearing housing as foaming and high bearing temperatures may result.

[ ] Regrease sludge mixing pump motor bearings with one of the following:

Sun Oil Multi-Purpose #2EP Mobil Mobilux #2EP Shell Alvania #2EP Texaco Multipak #2EP Exxon Lidok #2EP

Motors can be regreased by stopping the motor, removing drain plug and pumping new grease into fill hole. Use a low pressure grease gun and avoid overgreasing. Run motor with drain plug removed until excess grease has been discharged (minimum 10 minutes). Stop motor and replace drain plug.

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0051PM - 6-MONTH USST SLUDGE MIXING PUMPS 1A-1C O&M SERVICE6 MonthsPreventive maintenanceIBW-ROUTE-00513E-00001473PUMP 1C, MIXING, SLUDGE, USST 02213-SMP1CO&M manual - Area 7 USST. Refer to pdf pages 54-55; O&M page 5.7-2 to 5.7-3

[ ] Regrease sludge mixing pump bearings with one of the following:

Mobil DTE Medium Exxon Teresstic 68 Shell Tellus 68

The hearing housing is equipped with a breather cap on top and a sight gauge on the side. Oil is added by removing the breather and filling the housing until the oil level is about half way up the sight gauge.

Do not overfill the bearing housing as foaming and high bearing temperatures may result.

[ ] Regrease sludge mixing pump motor bearings with one of the following:

Sun Oil Multi-Purpose #2EP Mobil Mobilux #2EP Shell Alvania #2EP Texaco Multipak #2EP Exxon Lidok #2EP

Motors can be regreased by stopping the motor, removing drain plug and pumping new grease into fill hole. Use a low pressure grease gun and avoid overgreasing. Run motor with drain plug removed until excess grease has been discharged (minimum 10 minutes). Stop motor and replace drain plug.

Tools:IBW-MAINTVMECH
WWTPIBW-PM-0079PM - ANNUAL HEADWORKS SCREENING CONVEYOR O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-00792E-00001072CONVEYOR 1, SCREENING, HW 00160-CNV1O&M manual - Area 1 Headworks. Refer to pdf pages 109-110; O&M pages 5.1-8 - 5.1-9

[ ] Change worm gear speed reducer oil with one of the following:

Shell SAE 30 Mobil SAE 30 Chevron SAE 30 [ ] Change the idler bearing housing oil with one of the oils listed above.

[ ] Change the drive chain oil with one of the oils listed above.

Tools:

IBW-MAINTVMECH
WWTPIBW-PM-0079PM - ANNUAL HEADWORKS SCREENING CONVEYOR O&M SERVICE12 MonthsPreventive maintenanceIBW-ROUTE-00792E-00001716CONVEYOR 2, SCREENING, HW 00170-CNV2O&M manual - Area 1 Headworks. Refer to pdf pages 109-110; O&M pages 5.1-8 - 5.1-9

[ ] Change worm gear speed reducer oil with one of the following:

Shell SAE 30 Mobil SAE 30 Chevron SAE 30 [ ] Change the idler bearing housing oil with one of the oils listed above.

[ ] Change the drive chain oil with one of the oils listed above.

Tools:

IBW-MAINTVMECH
WWTPIBW-PM-0085PM - ANNUAL TRUCK LOADING SCALE INSPECTION12 MonthsPreventive maintenanceIBW-ROUTE-00852E-00000527SCALE 2, LOADING, SLUDGE 02813-SLS2[ ] Lubricate Load Receivers (Mystic Jt-6 Ht)

[ ] Inspect Scale Frame And Linkages For Damage.

[ ] Have Scales Re-Certified (Call Outside Vendor)

IBW-OPERVMECH
WWTPIBW-PM-0085PM - ANNUAL TRUCK LOADING SCALE INSPECTION12 MonthsPreventive maintenanceIBW-ROUTE-00852E-00000526SCALE 1, LOADING, SLUDGE 02813-SLS1[ ] Lubricate Load Receivers (Mystic Jt-6 Ht)

[ ] Inspect Scale Frame And Linkages For Damage.

[ ] Have Scales Re-Certified (Call Outside Vendor)

IBW-OPERVMECH
WWTPIBW-PM-0114PM - MONTHLY SCAB BLOWERS 1-3 O&M SERVICE1 MonthsPreventive maintenanceIBW-ROUTE-01143E-00000133BLOWER 1, AIR, SECONDARY CHANNEL (SCAB) SCAB1O&M Manual - Area 3 Aeration. Refer to pdf page 123; O&M page 5.3-10

SAFETY:

[ ] PERFORM LOTO PER VEOLIA POLICY, IF INSPECTION REQUIRES SHUTDOWN OF BLOWER

O&M TASK INSTRUCTIONS:

[ ] Check motor operation for excessive vibration and hot spots.

[ ] Check tension in V-belts, and examine for wear.

**NOTE: CREATE A CM WO FOR ANY REPAIRS DISCOVERED DURING THIS PMIBW-MAINTVMECH
WWTPIBW-PM-0114PM - MONTHLY SCAB BLOWERS 1-3 O&M SERVICE1 MonthsPreventive maintenanceIBW-ROUTE-01143E-00000135BLOWER 3, AIR, SECONDARY CHANNEL (SCAB) SCAB3O&M Manual - Area 3 Aeration. Refer to pdf page 123; O&M page 5.3-10

SAFETY:

[ ] PERFORM LOTO PER VEOLIA POLICY, IF INSPECTION REQUIRES SHUTDOWN OF BLOWER

O&M TASK INSTRUCTIONS:

[ ] Check motor operation for excessive vibration and hot spots.

[ ] Check tension in V-belts, and examine for wear.

**NOTE: CREATE A CM WO FOR ANY REPAIRS DISCOVERED DURING THIS PMIBW-MAINTVMECH
WWTPIBW-PM-0114PM - MONTHLY SCAB BLOWERS 1-3 O&M SERVICE1 MonthsPreventive maintenanceIBW-ROUTE-01143E-00000134BLOWER 2, AIR, SECONDARY CHANNEL (SCAB) SCAB2O&M Manual - Area 3 Aeration. Refer to pdf page 123; O&M page 5.3-10

SAFETY:

[ ] PERFORM LOTO PER VEOLIA POLICY, IF INSPECTION REQUIRES SHUTDOWN OF BLOWER

O&M TASK INSTRUCTIONS:

[ ] Check motor operation for excessive vibration and hot spots.

[ ] Check tension in V-belts, and examine for wear.

**NOTE: CREATE A CM WO FOR ANY REPAIRS DISCOVERED DURING THIS PMIBW-MAINTVMECH
Lift StationsIBW-PM-0116PM - MONTHLY LIFTSTATION BUBBLER INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-01163E-00000034PANEL, CONTROL, BUBBLER, GCPS 04102-BCP-GCPS[ ] Drain Condensation From Reservoir Tank And Filter / Regulator assembly.

[ ] Perform Manual Purge Cycle, By Pressing Button On Front Pannel.

[ ] Close Air Valve To Vault, Remove Pipe Plug And Install Hose Bib.

[ ] Connect Hose And Flush Balance Pipe For 5 Minutes.

[ ] Remove Hose Bib, Install Plug And Open Air Valve.

[ ] Repeat For Second Vault.

[ ] Verify Bubbler Operation. Troubleshoot and replace defective components if compressor runs continuously.

[ ] Check And Clear Codes From PLCIBW-INSTRUMENTVMECH
Lift StationsIBW-PM-0116PM - MONTHLY LIFTSTATION BUBBLER INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-01163E-00000603PANEL, BUBBLER, STRUCTURE, ANTI-INTRUSION 01541-AIS-BUBBLER[ ] Drain Condensation From Reservoir Tank And Filter / Regulator assembly.

[ ] Perform Manual Purge Cycle, By Pressing Button On Front Pannel.

[ ] Close Air Valve To Vault, Remove Pipe Plug And Install Hose Bib.

[ ] Connect Hose And Flush Balance Pipe For 5 Minutes.

[ ] Remove Hose Bib, Install Plug And Open Air Valve.

[ ] Repeat For Second Vault.

[ ] Verify Bubbler Operation. Troubleshoot and replace defective components if compressor runs continuously.

[ ] Check And Clear Codes From PLCIBW-INSTRUMENTVMECH
Lift StationsIBW-PM-0116PM - MONTHLY LIFTSTATION BUBBLER INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-01163E-00000084PANEL, CONTROL, BUBBLER, HPS 04302-BCP-HPS[ ] Drain Condensation From Reservoir Tank And Filter / Regulator assembly.

[ ] Perform Manual Purge Cycle, By Pressing Button On Front Pannel.

[ ] Close Air Valve To Vault, Remove Pipe Plug And Install Hose Bib.

[ ] Connect Hose And Flush Balance Pipe For 5 Minutes.

[ ] Remove Hose Bib, Install Plug And Open Air Valve.

[ ] Repeat For Second Vault.

[ ] Verify Bubbler Operation. Troubleshoot and replace defective components if compressor runs continuously.

[ ] Check And Clear Codes From PLCIBW-INSTRUMENTVMECH
WWTPIBW-PM-0119PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-011913E-00000435AREA, FERRIC, PRIMARY SEDIMENTATION 00580-FERRIC-BLDG[ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed.
[ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through.IBW-OPERVMECH
WWTPIBW-PM-0119PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-011913E-00000481CONTAINMENT, SODIUM HYPOCHLORITE, ORPST 00678-CONTAIN[ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed.
[ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through.IBW-OPERVMECH
WWTPIBW-PM-0119PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-011913E-00000953SCRUBBER 4, ORSP 03705-ORSC4[ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed.
[ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through.IBW-OPERVMECH
WWTPIBW-PM-0119PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-011913E-00000487CONTAINMENT, CAUSTIC, ORSP 03728-CONTAIN[ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed.
[ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through.IBW-OPERVMECH
WWTPIBW-PM-0119PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-011913E-00000469CONTAINMENT, CAUSTIC, ORHW 00368-CONTAIN[ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed.
[ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through.IBW-OPERVMECH
WWTPIBW-PM-0119PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-011913E-00000979SCRUBBER, TOWER 3, ORUSS 02255-ORSC3[ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed.
[ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through.IBW-OPERVMECH
WWTPIBW-PM-0119PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-011913E-00000436CONTAINMENT, FERRIC CHLORIDE, PST 00580-CONTAIN[ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed.
[ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through.IBW-OPERVMECH
WWTPIBW-PM-0119PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-011913E-00000432CONTAINMENT, POLYMER, PRIMARY SEDIMENTATION 00550-CONTAIN[ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed.
[ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through.IBW-OPERVMECH
WWTPIBW-PM-0119PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-011913E-00000536CONTAINMENT, STORAGE, POLYMER, BULK, SP 02601-CONTAIN[ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed.
[ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through.IBW-OPERVMECH
WWTPIBW-PM-0119PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-011913E-00000531AREA, USST 02200-USST-BLDG[ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed.
[ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through.IBW-OPERVMECH
WWTPIBW-PM-0119PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-011913E-00000955SCRUBBER 5, ORSP 03715-ORSC5[ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed.
[ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through.IBW-OPERVMECH
WWTPIBW-PM-0119PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-011913E-00000932SCRUBBER, ORPST 00655-ORSC2[ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed.
[ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through.IBW-OPERVMECH
WWTPIBW-PM-0119PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-011913E-00000482CONTAINMENT, CAUSTIC, ORPST 00668-CONTAIN[ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed.
[ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through.IBW-OPERVMECH
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000888PANEL, CONTROL, FIRE ALARM, PST (FACP) 00422-LCP-FACP[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00001577PANEL 1, FIRE ALARM, DAF DAF-FAP-01[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000882PANEL, CONTROL, FIRE ALARM, HW (FACP) 00100-LCP-FACP[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00001578PANEL 4, FIRE ALARM, (ROOM 209) FAP-04[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00001579PANEL 5, FIRE ALARM, (HALLWAY) FAP-05[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000884PANEL, CONTROL, FIRE ALARM, MSG (FACP) 03180-LCP-FACP[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000886PANEL, CONTROL, FIRE ALARM, PERSONNEL BUILDING (FACP) 02612-LCP-FACP2[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000887CHARGER, BATTERY, FACP, PST 00422-CHRG-FACP[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000878PANEL, CONTROL, FIRE ALARM, CL2 FACILITY (FACP) 01313-LCP-FACP[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000889CHARGER, BATTERY, FACP, SLUDGE DEWATER 02612-CHRG-FACP1[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000007PANEL, CONTROL, FIRE ALARM, GCPS 04118-LCP-FACP[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00001587PANEL 2, FIRE ALARM, SST SST-FAP-02[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000883CHARGER, BATTERY, FACP, MSB 01301-CHRG-FACP[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000056PANEL, CONTROL, FIRE ALARM, HPS 04318-LCP-FACP[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000881CHARGER, BATTERY, FACP, HW 00100-CHRG-FACP[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000879PANEL 3, FIRE ALARM AST-FAP-03[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000877CHARGER, BATTERY, FACP, FACILITY, CL2 01313-CHRG-FACP[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000890PANEL, CONTROL, FIRE ALARM, SLUDGE DEWATERING (FACP) 02612-LCP-FACP1[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0129PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION1 MonthsPreventive maintenanceIBW-ROUTE-012919E-00000885CHARGER, BATTERY, FACP, PERSONNEL BLDG 02612-CHRG-FACP2[ ] Check all connections for tightness - Tighten connections/terminals.

[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed

[ ] Check Battery Charging Voltage 27-27.5 - service as neededIBW-INSTRUMENTVEI
Lift StationsIBW-PM-0137PM - MONTHLY GCPS & HPS SURGE ARRESTERS TANKS O&M SERVICE1 MonthsPreventive maintenanceIBW-ROUTE-01374E-00000045TANK 1, SURGE, GCPS 04108-SA1O&M manual - Area 13 Canyon Collectors & Lift Stations. Refer to pdf pages 143 or 157; O&M pages 5.13-8 or 5.13-24

[ ] Inspect all threaded and bolted connections to the vessels to ensure they are secure.

[ ] Check the gage valves for signs of leakage around stem area. Stem packing leakage can often be stopped by tightening the stem packing nut. If leak persists, replace the stem packing.

[ ] Check the gage valves for signs of internal stem leak. Replace stem or renew seat surface as needed.

[ ] Check the gage valves for signs of leakage around stuffing box connection. Replace glass packing as needed. In the event of improper packing compression, leakage can be stopped by tightening gage coupling nut.

[ ] Check the gage valves for signs of internal or external corrosion. Conduct investigation as to the cause of the problem as appropriate.IBW-MAINTVHVYEQ
Lift StationsIBW-PM-0137PM - MONTHLY GCPS & HPS SURGE ARRESTERS TANKS O&M SERVICE1 MonthsPreventive maintenanceIBW-ROUTE-01374E-00000098TANK 2, SURGE, HPS 04309-SA2O&M manual - Area 13 Canyon Collectors & Lift Stations. Refer to pdf pages 143 or 157; O&M pages 5.13-8 or 5.13-24

[ ] Inspect all threaded and bolted connections to the vessels to ensure they are secure.

[ ] Check the gage valves for signs of leakage around stem area. Stem packing leakage can often be stopped by tightening the stem packing nut. If leak persists, replace the stem packing.

[ ] Check the gage valves for signs of internal stem leak. Replace stem or renew seat surface as needed.

[ ] Check the gage valves for signs of leakage around stuffing box connection. Replace glass packing as needed. In the event of improper packing compression, leakage can be stopped by tightening gage coupling nut.

[ ] Check the gage valves for signs of internal or external corrosion. Conduct investigation as to the cause of the problem as appropriate.IBW-MAINTVHVYEQ
Lift StationsIBW-PM-0137PM - MONTHLY GCPS & HPS SURGE ARRESTERS TANKS O&M SERVICE1 MonthsPreventive maintenanceIBW-ROUTE-01374E-00000097TANK 1, SURGE, HPS 04308-SA1O&M manual - Area 13 Canyon Collectors & Lift Stations. Refer to pdf pages 143 or 157; O&M pages 5.13-8 or 5.13-24

[ ] Inspect all threaded and bolted connections to the vessels to ensure they are secure.

[ ] Check the gage valves for signs of leakage around stem area. Stem packing leakage can often be stopped by tightening the stem packing nut. If leak persists, replace the stem packing.

[ ] Check the gage valves for signs of internal stem leak. Replace stem or renew seat surface as needed.

[ ] Check the gage valves for signs of leakage around stuffing box connection. Replace glass packing as needed. In the event of improper packing compression, leakage can be stopped by tightening gage coupling nut.

[ ] Check the gage valves for signs of internal or external corrosion. Conduct investigation as to the cause of the problem as appropriate.IBW-MAINTVHVYEQ
Lift StationsIBW-PM-0137PM - MONTHLY GCPS & HPS SURGE ARRESTERS TANKS O&M SERVICE1 MonthsPreventive maintenanceIBW-ROUTE-01374E-00000046TANK 2, SURGE, GCPS 04109-SA2O&M manual - Area 13 Canyon Collectors & Lift Stations. Refer to pdf pages 143 or 157; O&M pages 5.13-8 or 5.13-24

[ ] Inspect all threaded and bolted connections to the vessels to ensure they are secure.

[ ] Check the gage valves for signs of leakage around stem area. Stem packing leakage can often be stopped by tightening the stem packing nut. If leak persists, replace the stem packing.

[ ] Check the gage valves for signs of internal stem leak. Replace stem or renew seat surface as needed.

[ ] Check the gage valves for signs of leakage around stuffing box connection. Replace glass packing as needed. In the event of improper packing compression, leakage can be stopped by tightening gage coupling nut.

[ ] Check the gage valves for signs of internal or external corrosion. Conduct investigation as to the cause of the problem as appropriate.IBW-MAINTVHVYEQ
WWTPIBW-PM-0164PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-016410E-00001292PANEL, LCP, HVAC UNIT, PRIMARY SKIMMINGS, PST 00418-HVAC-PSKPS[ ] Clean HVAC Condensor Coils

[ ] Clean Inlet Screen To HVAC Units

[ ] Check Unit For Proper OperationIBW-MAINTVMECH
WWTPIBW-PM-0164PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-016410E-00000732PANEL, CONTROL, HVAC UNIT, LIME, SP 02800-HVAC-LS1[ ] Clean HVAC Condensor Coils

[ ] Clean Inlet Screen To HVAC Units

[ ] Check Unit For Proper OperationIBW-MAINTVMECH
WWTPIBW-PM-0164PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-016410E-00000460HVAC UNIT, LCP-ES, EBS 01500-HVAC-LCP-ES[ ] Clean HVAC Condensor Coils

[ ] Clean Inlet Screen To HVAC Units

[ ] Check Unit For Proper OperationIBW-MAINTVMECH
WWTPIBW-PM-0164PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-016410E-00001492HVAC UNIT, AFD, CONVEYOR 2, TRUCK LOADING 02851-HVAC-TLC2[ ] Clean HVAC Condensor Coils

[ ] Clean Inlet Screen To HVAC Units

[ ] Check Unit For Proper OperationIBW-MAINTVMECH
WWTPIBW-PM-0164PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-016410E-00000922PANEL, CONTROL, LOCAL, HVAC UNIT, ORPST 00419-HVAC-ORPST[ ] Clean HVAC Condensor Coils

[ ] Clean Inlet Screen To HVAC Units

[ ] Check Unit For Proper OperationIBW-MAINTVMECH
WWTPIBW-PM-0164PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-016410E-00001393PANEL, CONTROL, LOCAL, HVAC UNIT, PEB 00620-HVAC-LCP-PEB[ ] Clean HVAC Condensor Coils

[ ] Clean Inlet Screen To HVAC Units

[ ] Check Unit For Proper OperationIBW-MAINTVMECH
WWTPIBW-PM-0164PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-016410E-00000906PANEL, CONTROL, LOCAL, HVAC UNIT, ORHW 00350-HVAC-ORHW[ ] Clean HVAC Condensor Coils

[ ] Clean Inlet Screen To HVAC Units

[ ] Check Unit For Proper OperationIBW-MAINTVMECH
WWTPIBW-PM-0164PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-016410E-00000963PANEL, CONTROL, LOCAL, HVAC UNIT, ORUSS 02250-HVAC-ORUSS[ ] Clean HVAC Condensor Coils

[ ] Clean Inlet Screen To HVAC Units

[ ] Check Unit For Proper OperationIBW-MAINTVMECH
WWTPIBW-PM-0164PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-016410E-00000936PANEL, CONTROL, LOCAL, HVAC UNIT 2, ORSP 03700-HVAC-ORSP2[ ] Clean HVAC Condensor Coils

[ ] Clean Inlet Screen To HVAC Units

[ ] Check Unit For Proper OperationIBW-MAINTVMECH
WWTPIBW-PM-0164PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-016410E-00000935PANEL, CONTROL, LOCAL, HVAC UNIT 1, ORSP 03700-HVAC-ORSP1[ ] Clean HVAC Condensor Coils

[ ] Clean Inlet Screen To HVAC Units

[ ] Check Unit For Proper OperationIBW-MAINTVMECH
WWTPIBW-PM-0173PM - QUARTERLY ORSP CHEMICAL PUMP INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-01734E-00000707PUMP 14, METERING, CAUSTIC, ORSP 03727-ORMP14[ ] Check Hydraulic fluid levels on Pulsar Series 25 Pulsafeeders - Service If Low Or Contaminated with 7H Hydraulic Fluid.

[ ] Check Oil Level In Series 680 and 880 pumps - Service If Low Or Contaminated with ISO GST 68.

[ ] Check Intermediate Chamber For Proper Glycol Levels: (Only If A Leak Is Indicated Or Pump Efficiency Is Low) ** Insure That The Pump Piston Stroke Is All The Way Back Before Removing Bolt.

Otherwise Pump Will Have To Be Re-Timed.

[ ] Torque Bolts On Pump Head To Proper Ft-Lbs - Refer To O&M Manuals For Proper Settings.

** Do Not Overtighten Bolts Or You Will Stretch The Bolt Hole Threads.

[ ] Check Pressure On Pulsation Dampner - Service If Low Torque Location Model "Reagent Head (Ft-Lb)" "Tie-Bar (In-Lb)" ORSP NaOcl Pump 880 5.9 9.3 ORSP NaOh Pump 680 5.8 12.2

ORSP H2SO4 Pump 680 5.8 12.2IBW-MAINTVMECH
WWTPIBW-PM-0173PM - QUARTERLY ORSP CHEMICAL PUMP INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-01734E-00000711PUMP 15, METERING, SODIUM HYPOCHLORITE, ORSP 03731-ORMP15[ ] Check Hydraulic fluid levels on Pulsar Series 25 Pulsafeeders - Service If Low Or Contaminated with 7H Hydraulic Fluid.

[ ] Check Oil Level In Series 680 and 880 pumps - Service If Low Or Contaminated with ISO GST 68.

[ ] Check Intermediate Chamber For Proper Glycol Levels: (Only If A Leak Is Indicated Or Pump Efficiency Is Low) ** Insure That The Pump Piston Stroke Is All The Way Back Before Removing Bolt.

Otherwise Pump Will Have To Be Re-Timed.

[ ] Torque Bolts On Pump Head To Proper Ft-Lbs - Refer To O&M Manuals For Proper Settings.

** Do Not Overtighten Bolts Or You Will Stretch The Bolt Hole Threads.

[ ] Check Pressure On Pulsation Dampner - Service If Low Torque Location Model "Reagent Head (Ft-Lb)" "Tie-Bar (In-Lb)" ORSP NaOcl Pump 880 5.9 9.3 ORSP NaOh Pump 680 5.8 12.2

ORSP H2SO4 Pump 680 5.8 12.2IBW-MAINTVMECH
WWTPIBW-PM-0173PM - QUARTERLY ORSP CHEMICAL PUMP INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-01734E-00000712PUMP 16, METERING, SODIUM HYPOCHLORITE, ORSP 03732-ORMP16[ ] Check Hydraulic fluid levels on Pulsar Series 25 Pulsafeeders - Service If Low Or Contaminated with 7H Hydraulic Fluid.

[ ] Check Oil Level In Series 680 and 880 pumps - Service If Low Or Contaminated with ISO GST 68.

[ ] Check Intermediate Chamber For Proper Glycol Levels: (Only If A Leak Is Indicated Or Pump Efficiency Is Low) ** Insure That The Pump Piston Stroke Is All The Way Back Before Removing Bolt.

Otherwise Pump Will Have To Be Re-Timed.

[ ] Torque Bolts On Pump Head To Proper Ft-Lbs - Refer To O&M Manuals For Proper Settings.

** Do Not Overtighten Bolts Or You Will Stretch The Bolt Hole Threads.

[ ] Check Pressure On Pulsation Dampner - Service If Low Torque Location Model "Reagent Head (Ft-Lb)" "Tie-Bar (In-Lb)" ORSP NaOcl Pump 880 5.9 9.3 ORSP NaOh Pump 680 5.8 12.2

ORSP H2SO4 Pump 680 5.8 12.2IBW-MAINTVMECH
WWTPIBW-PM-0173PM - QUARTERLY ORSP CHEMICAL PUMP INSPECTION3 MonthsPreventive maintenanceIBW-ROUTE-01734E-00000706PUMP 13, METERING, CAUSTIC, ORSP 03726-ORMP13[ ] Check Hydraulic fluid levels on Pulsar Series 25 Pulsafeeders - Service If Low Or Contaminated with 7H Hydraulic Fluid.

[ ] Check Oil Level In Series 680 and 880 pumps - Service If Low Or Contaminated with ISO GST 68.

[ ] Check Intermediate Chamber For Proper Glycol Levels: (Only If A Leak Is Indicated Or Pump…