PM Details w Equipment Routes
| Department | PM Schedule | Preventative Maint. (PM) Description | Interval | Work Order Type | Route | Route Eq. Count | Route Equipment | Equipment Description | Task Instructions | Crew | Trade |
| WWTP | IBW-PM-0004 | PM - MONTHLY COMPRESSOR FILTER INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0004 | 8 | E-00001725 | COMPRESSOR, AIR, BLOWER BUILDING PABCMP, Quincy Model QT5 | [ ] Inspect and clean/replace Air Filters (If Needed). | IBW-MAINT | VMECH |
| WWTP | IBW-PM-0004 | PM - MONTHLY COMPRESSOR FILTER INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0004 | 8 | E-00001038 | COMPRESSOR UNIT, AIR, PURGE, SP 02600-PURGE1, Campbell Hausfeld, TF061903AV | [ ] Inspect and clean/replace Air Filters (If Needed). | IBW-MAINT | VMECH |
| WWTP | IBW-PM-0004 | PM - MONTHLY COMPRESSOR FILTER INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0004 | 8 | E-00000549 | COMPRESSOR, 5 HP, MAINTENANCE GARAGE 02610-SHOP-COMP1 | [ ] Inspect and clean/replace Air Filters (If Needed). | IBW-MAINT | VMECH |
| WWTP | IBW-PM-0004 | PM - MONTHLY COMPRESSOR FILTER INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0004 | 8 | E-00001541 | COMPRESSOR, AIR, PORTABLE, INGERSOLL-RAND 03801-AIR-PORTABLE | [ ] Inspect and clean/replace Air Filters (If Needed). | IBW-MAINT | VMECH |
| WWTP | IBW-PM-0004 | PM - MONTHLY COMPRESSOR FILTER INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0004 | 8 | E-00001296 | COMPRESSOR 2, FILL, TANK, HYDROPNEUMATIC, NPW 01345-HTFC2 | [ ] Inspect and clean/replace Air Filters (If Needed). | IBW-MAINT | VMECH |
| WWTP | IBW-PM-0004 | PM - MONTHLY COMPRESSOR FILTER INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0004 | 8 | E-00001295 | COMPRESSOR 1, FILL, TANK, HYDROPNEUMATIC, NPW 01345-HTFC1 | [ ] Inspect and clean/replace Air Filters (If Needed). | IBW-MAINT | VMECH |
| WWTP | IBW-PM-0004 | PM - MONTHLY COMPRESSOR FILTER INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0004 | 8 | E-00001867 | Compressor, Air, Maint Bldg, Polar Air | [ ] Inspect and clean/replace Air Filters (If Needed). | IBW-MAINT | VMECH |
| WWTP | IBW-PM-0004 | PM - MONTHLY COMPRESSOR FILTER INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0004 | 8 | E-00001858 | Compressor, Air, Speedaire, 4B250A, Grit Gallery | [ ] Inspect and clean/replace Air Filters (If Needed). | IBW-MAINT | VMECH |
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00001003 | ACTUATOR, GATE 2, EFFLUENT, SECONDARY, EBS 01503-MV-SEG1 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation [ ] Check Gear Case Oil Level - Fill If Necessary [ ] Inspect Concrete, Pedestal And Yoke For Cracks Or Deterioration.
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00000984 | GATE 1, SLUICE, INLET, WEIR, OVERFLOW, EDS, 72" (ME14) 01540-EDS-ME14 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00000990 | GATE, SLUICE, INLET, DISTRIBUTION, EFFLUENT, 96" (ME11) 01540-EDS-ME11 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00000983 | GATE 2, SLUICE, INLET, DISSIPATION, ENERGY, 144" (ME13) 01540-EDS-ME13 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00000986 | GATE, SLUICE, INLET, SBWRT, EDS, 72" (FUTURE) (ME18) 01540-EDS-ME18 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00000999 | ACTUATOR, GATE 1, EFFLUENT, BLENDED, EBS 01504-MV-BEG1 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00000998 | GATE 1, EFFLUENT, BLENDED, EBS 01504-G-SLIDE-BEG1 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00001095 | GATE, SLUICE, 96", JB-1 00100-GATE-JB1-96 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00001002 | GATE 2, EFFLUENT, SECONDARY, EBS 01503-G-SLIDE-SEG1 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00000982 | GATE 1, SLUICE, INLET, DISSIPATION, ENERGY, 144" (ME12) 01540-EDS-ME12 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00000991 | GATE, SLUICE, RE-USE, MEXICO, EDS, (FUTURE) (ME17) 01540-EDS-ME17 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00001001 | GATE 1, BYPASS, EFFLUENT, PRIMARY, EBS 01502-G-SLIDE-PEBG1 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00000985 | GATE 2, SLUICE, INLET, WEIR, OVERFLOW, EDS, 72" (ME15) 01540-EDS-ME15 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0027 | PM - ANNUAL EFFLUENT SLUICE GATES & ACTUATORS O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0027 | 14 | E-00001000 | ACTUATOR, GATE 1, BYPASS, EFFLUENT, PRIMARY, EBS 01502-MV-PEBG1 | O&M manual - Area 12 Generators. Refer to pdf page 50; O&M page 5.12-7 |
[ ] Remove the lift nut and inspect for wear. If excessive wear is evident the lift nut should be replaced.
**Electric Actuator O&M** [ ] Replace all fluid filter cartridges in use for over 6 months.
[ ] Check quality of hydraulic oil. If contaminated, change with one of the oils indicated below:
Chevron Hydraulic Oil #AW150HYD46 Shell Tellus 46 Unocal Unax AW46 [ ] Check pump and motor alignment. Correct as required.
[ ] Grease the motor with one of the following:
Shell Oil Dolium R Chevron SRI NLGI #2
**Electric Actuator O&M** [ ] Check Actuator For Damage And Wear [ ] Inspect Actuator Electrical Enclosure, Wires, Terminals, Switches And Lamps [ ] Check Manual Operator For Proper Operation
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0051 | PM - 6-MONTH USST SLUDGE MIXING PUMPS 1A-1C O&M SERVICE | 6 Months | Preventive maintenance | IBW-ROUTE-0051 | 3 | E-00001469 | PUMP 1A, MIXING, SLUDGE, USST 02211-SMP1A | O&M manual - Area 7 USST. Refer to pdf pages 54-55; O&M page 5.7-2 to 5.7-3 |
[ ] Regrease sludge mixing pump bearings with one of the following:
Mobil DTE Medium Exxon Teresstic 68 Shell Tellus 68
The hearing housing is equipped with a breather cap on top and a sight gauge on the side. Oil is added by removing the breather and filling the housing until the oil level is about half way up the sight gauge.
Do not overfill the bearing housing as foaming and high bearing temperatures may result.
[ ] Regrease sludge mixing pump motor bearings with one of the following:
Sun Oil Multi-Purpose #2EP Mobil Mobilux #2EP Shell Alvania #2EP Texaco Multipak #2EP Exxon Lidok #2EP
Motors can be regreased by stopping the motor, removing drain plug and pumping new grease into fill hole. Use a low pressure grease gun and avoid overgreasing. Run motor with drain plug removed until excess grease has been discharged (minimum 10 minutes). Stop motor and replace drain plug.
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0051 | PM - 6-MONTH USST SLUDGE MIXING PUMPS 1A-1C O&M SERVICE | 6 Months | Preventive maintenance | IBW-ROUTE-0051 | 3 | E-00001471 | PUMP 1B, MIXING, SLUDGE, USST 02212-SMP1B | O&M manual - Area 7 USST. Refer to pdf pages 54-55; O&M page 5.7-2 to 5.7-3 |
[ ] Regrease sludge mixing pump bearings with one of the following:
Mobil DTE Medium Exxon Teresstic 68 Shell Tellus 68
The hearing housing is equipped with a breather cap on top and a sight gauge on the side. Oil is added by removing the breather and filling the housing until the oil level is about half way up the sight gauge.
Do not overfill the bearing housing as foaming and high bearing temperatures may result.
[ ] Regrease sludge mixing pump motor bearings with one of the following:
Sun Oil Multi-Purpose #2EP Mobil Mobilux #2EP Shell Alvania #2EP Texaco Multipak #2EP Exxon Lidok #2EP
Motors can be regreased by stopping the motor, removing drain plug and pumping new grease into fill hole. Use a low pressure grease gun and avoid overgreasing. Run motor with drain plug removed until excess grease has been discharged (minimum 10 minutes). Stop motor and replace drain plug.
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0051 | PM - 6-MONTH USST SLUDGE MIXING PUMPS 1A-1C O&M SERVICE | 6 Months | Preventive maintenance | IBW-ROUTE-0051 | 3 | E-00001473 | PUMP 1C, MIXING, SLUDGE, USST 02213-SMP1C | O&M manual - Area 7 USST. Refer to pdf pages 54-55; O&M page 5.7-2 to 5.7-3 |
[ ] Regrease sludge mixing pump bearings with one of the following:
Mobil DTE Medium Exxon Teresstic 68 Shell Tellus 68
The hearing housing is equipped with a breather cap on top and a sight gauge on the side. Oil is added by removing the breather and filling the housing until the oil level is about half way up the sight gauge.
Do not overfill the bearing housing as foaming and high bearing temperatures may result.
[ ] Regrease sludge mixing pump motor bearings with one of the following:
Sun Oil Multi-Purpose #2EP Mobil Mobilux #2EP Shell Alvania #2EP Texaco Multipak #2EP Exxon Lidok #2EP
Motors can be regreased by stopping the motor, removing drain plug and pumping new grease into fill hole. Use a low pressure grease gun and avoid overgreasing. Run motor with drain plug removed until excess grease has been discharged (minimum 10 minutes). Stop motor and replace drain plug.
| Tools: | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0079 | PM - ANNUAL HEADWORKS SCREENING CONVEYOR O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0079 | 2 | E-00001072 | CONVEYOR 1, SCREENING, HW 00160-CNV1 | O&M manual - Area 1 Headworks. Refer to pdf pages 109-110; O&M pages 5.1-8 - 5.1-9 |
[ ] Change worm gear speed reducer oil with one of the following:
Shell SAE 30 Mobil SAE 30 Chevron SAE 30 [ ] Change the idler bearing housing oil with one of the oils listed above.
[ ] Change the drive chain oil with one of the oils listed above.
Tools:
| IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0079 | PM - ANNUAL HEADWORKS SCREENING CONVEYOR O&M SERVICE | 12 Months | Preventive maintenance | IBW-ROUTE-0079 | 2 | E-00001716 | CONVEYOR 2, SCREENING, HW 00170-CNV2 | O&M manual - Area 1 Headworks. Refer to pdf pages 109-110; O&M pages 5.1-8 - 5.1-9 |
[ ] Change worm gear speed reducer oil with one of the following:
Shell SAE 30 Mobil SAE 30 Chevron SAE 30 [ ] Change the idler bearing housing oil with one of the oils listed above.
[ ] Change the drive chain oil with one of the oils listed above.
Tools:
| IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0085 | PM - ANNUAL TRUCK LOADING SCALE INSPECTION | 12 Months | Preventive maintenance | IBW-ROUTE-0085 | 2 | E-00000527 | SCALE 2, LOADING, SLUDGE 02813-SLS2 | [ ] Lubricate Load Receivers (Mystic Jt-6 Ht) |
[ ] Inspect Scale Frame And Linkages For Damage.
[ ] Have Scales Re-Certified (Call Outside Vendor)
| IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0085 | PM - ANNUAL TRUCK LOADING SCALE INSPECTION | 12 Months | Preventive maintenance | IBW-ROUTE-0085 | 2 | E-00000526 | SCALE 1, LOADING, SLUDGE 02813-SLS1 | [ ] Lubricate Load Receivers (Mystic Jt-6 Ht) |
[ ] Inspect Scale Frame And Linkages For Damage.
[ ] Have Scales Re-Certified (Call Outside Vendor)
| IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0114 | PM - MONTHLY SCAB BLOWERS 1-3 O&M SERVICE | 1 Months | Preventive maintenance | IBW-ROUTE-0114 | 3 | E-00000133 | BLOWER 1, AIR, SECONDARY CHANNEL (SCAB) SCAB1 | O&M Manual - Area 3 Aeration. Refer to pdf page 123; O&M page 5.3-10 |
SAFETY:
[ ] PERFORM LOTO PER VEOLIA POLICY, IF INSPECTION REQUIRES SHUTDOWN OF BLOWER
O&M TASK INSTRUCTIONS:
[ ] Check motor operation for excessive vibration and hot spots.
[ ] Check tension in V-belts, and examine for wear.
| **NOTE: CREATE A CM WO FOR ANY REPAIRS DISCOVERED DURING THIS PM | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0114 | PM - MONTHLY SCAB BLOWERS 1-3 O&M SERVICE | 1 Months | Preventive maintenance | IBW-ROUTE-0114 | 3 | E-00000135 | BLOWER 3, AIR, SECONDARY CHANNEL (SCAB) SCAB3 | O&M Manual - Area 3 Aeration. Refer to pdf page 123; O&M page 5.3-10 |
SAFETY:
[ ] PERFORM LOTO PER VEOLIA POLICY, IF INSPECTION REQUIRES SHUTDOWN OF BLOWER
O&M TASK INSTRUCTIONS:
[ ] Check motor operation for excessive vibration and hot spots.
[ ] Check tension in V-belts, and examine for wear.
| **NOTE: CREATE A CM WO FOR ANY REPAIRS DISCOVERED DURING THIS PM | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0114 | PM - MONTHLY SCAB BLOWERS 1-3 O&M SERVICE | 1 Months | Preventive maintenance | IBW-ROUTE-0114 | 3 | E-00000134 | BLOWER 2, AIR, SECONDARY CHANNEL (SCAB) SCAB2 | O&M Manual - Area 3 Aeration. Refer to pdf page 123; O&M page 5.3-10 |
SAFETY:
[ ] PERFORM LOTO PER VEOLIA POLICY, IF INSPECTION REQUIRES SHUTDOWN OF BLOWER
O&M TASK INSTRUCTIONS:
[ ] Check motor operation for excessive vibration and hot spots.
[ ] Check tension in V-belts, and examine for wear.
| **NOTE: CREATE A CM WO FOR ANY REPAIRS DISCOVERED DURING THIS PM | IBW-MAINT | VMECH | ||||||||
| Lift Stations | IBW-PM-0116 | PM - MONTHLY LIFTSTATION BUBBLER INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0116 | 3 | E-00000034 | PANEL, CONTROL, BUBBLER, GCPS 04102-BCP-GCPS | [ ] Drain Condensation From Reservoir Tank And Filter / Regulator assembly. |
[ ] Perform Manual Purge Cycle, By Pressing Button On Front Pannel.
[ ] Close Air Valve To Vault, Remove Pipe Plug And Install Hose Bib.
[ ] Connect Hose And Flush Balance Pipe For 5 Minutes.
[ ] Remove Hose Bib, Install Plug And Open Air Valve.
[ ] Repeat For Second Vault.
[ ] Verify Bubbler Operation. Troubleshoot and replace defective components if compressor runs continuously.
| [ ] Check And Clear Codes From PLC | IBW-INSTRUMENT | VMECH | ||||||||
| Lift Stations | IBW-PM-0116 | PM - MONTHLY LIFTSTATION BUBBLER INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0116 | 3 | E-00000603 | PANEL, BUBBLER, STRUCTURE, ANTI-INTRUSION 01541-AIS-BUBBLER | [ ] Drain Condensation From Reservoir Tank And Filter / Regulator assembly. |
[ ] Perform Manual Purge Cycle, By Pressing Button On Front Pannel.
[ ] Close Air Valve To Vault, Remove Pipe Plug And Install Hose Bib.
[ ] Connect Hose And Flush Balance Pipe For 5 Minutes.
[ ] Remove Hose Bib, Install Plug And Open Air Valve.
[ ] Repeat For Second Vault.
[ ] Verify Bubbler Operation. Troubleshoot and replace defective components if compressor runs continuously.
| [ ] Check And Clear Codes From PLC | IBW-INSTRUMENT | VMECH | ||||||||
| Lift Stations | IBW-PM-0116 | PM - MONTHLY LIFTSTATION BUBBLER INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0116 | 3 | E-00000084 | PANEL, CONTROL, BUBBLER, HPS 04302-BCP-HPS | [ ] Drain Condensation From Reservoir Tank And Filter / Regulator assembly. |
[ ] Perform Manual Purge Cycle, By Pressing Button On Front Pannel.
[ ] Close Air Valve To Vault, Remove Pipe Plug And Install Hose Bib.
[ ] Connect Hose And Flush Balance Pipe For 5 Minutes.
[ ] Remove Hose Bib, Install Plug And Open Air Valve.
[ ] Repeat For Second Vault.
[ ] Verify Bubbler Operation. Troubleshoot and replace defective components if compressor runs continuously.
| [ ] Check And Clear Codes From PLC | IBW-INSTRUMENT | VMECH | ||||||||
| WWTP | IBW-PM-0119 | PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0119 | 13 | E-00000435 | AREA, FERRIC, PRIMARY SEDIMENTATION 00580-FERRIC-BLDG | [ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed. | |
| [ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through. | IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0119 | PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0119 | 13 | E-00000481 | CONTAINMENT, SODIUM HYPOCHLORITE, ORPST 00678-CONTAIN | [ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed. | |
| [ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through. | IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0119 | PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0119 | 13 | E-00000953 | SCRUBBER 4, ORSP 03705-ORSC4 | [ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed. | |
| [ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through. | IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0119 | PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0119 | 13 | E-00000487 | CONTAINMENT, CAUSTIC, ORSP 03728-CONTAIN | [ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed. | |
| [ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through. | IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0119 | PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0119 | 13 | E-00000469 | CONTAINMENT, CAUSTIC, ORHW 00368-CONTAIN | [ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed. | |
| [ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through. | IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0119 | PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0119 | 13 | E-00000979 | SCRUBBER, TOWER 3, ORUSS 02255-ORSC3 | [ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed. | |
| [ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through. | IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0119 | PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0119 | 13 | E-00000436 | CONTAINMENT, FERRIC CHLORIDE, PST 00580-CONTAIN | [ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed. | |
| [ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through. | IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0119 | PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0119 | 13 | E-00000432 | CONTAINMENT, POLYMER, PRIMARY SEDIMENTATION 00550-CONTAIN | [ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed. | |
| [ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through. | IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0119 | PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0119 | 13 | E-00000536 | CONTAINMENT, STORAGE, POLYMER, BULK, SP 02601-CONTAIN | [ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed. | |
| [ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through. | IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0119 | PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0119 | 13 | E-00000531 | AREA, USST 02200-USST-BLDG | [ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed. | |
| [ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through. | IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0119 | PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0119 | 13 | E-00000955 | SCRUBBER 5, ORSP 03715-ORSC5 | [ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed. | |
| [ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through. | IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0119 | PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0119 | 13 | E-00000932 | SCRUBBER, ORPST 00655-ORSC2 | [ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed. | |
| [ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through. | IBW-OPER | VMECH | ||||||||
| WWTP | IBW-PM-0119 | PM - MONTHLY ODOR CONTROL AND CHEMICAL STATIONS SYSTEM INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0119 | 13 | E-00000482 | CONTAINMENT, CAUSTIC, ORPST 00668-CONTAIN | [ ] Check All Fittings,Piping, Pumps, Tanks Feed/Return Locations. Fix Blockages/Leaks and Faulty Fittings As Needed. | |
| [ ] Cycle valves and pumps in the recirculation system. Open and clean discharge check valves that leak through. | IBW-OPER | VMECH | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000888 | PANEL, CONTROL, FIRE ALARM, PST (FACP) 00422-LCP-FACP | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00001577 | PANEL 1, FIRE ALARM, DAF DAF-FAP-01 | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000882 | PANEL, CONTROL, FIRE ALARM, HW (FACP) 00100-LCP-FACP | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00001578 | PANEL 4, FIRE ALARM, (ROOM 209) FAP-04 | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00001579 | PANEL 5, FIRE ALARM, (HALLWAY) FAP-05 | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000884 | PANEL, CONTROL, FIRE ALARM, MSG (FACP) 03180-LCP-FACP | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000886 | PANEL, CONTROL, FIRE ALARM, PERSONNEL BUILDING (FACP) 02612-LCP-FACP2 | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000887 | CHARGER, BATTERY, FACP, PST 00422-CHRG-FACP | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000878 | PANEL, CONTROL, FIRE ALARM, CL2 FACILITY (FACP) 01313-LCP-FACP | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000889 | CHARGER, BATTERY, FACP, SLUDGE DEWATER 02612-CHRG-FACP1 | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000007 | PANEL, CONTROL, FIRE ALARM, GCPS 04118-LCP-FACP | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00001587 | PANEL 2, FIRE ALARM, SST SST-FAP-02 | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000883 | CHARGER, BATTERY, FACP, MSB 01301-CHRG-FACP | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000056 | PANEL, CONTROL, FIRE ALARM, HPS 04318-LCP-FACP | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000881 | CHARGER, BATTERY, FACP, HW 00100-CHRG-FACP | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000879 | PANEL 3, FIRE ALARM AST-FAP-03 | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000877 | CHARGER, BATTERY, FACP, FACILITY, CL2 01313-CHRG-FACP | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000890 | PANEL, CONTROL, FIRE ALARM, SLUDGE DEWATERING (FACP) 02612-LCP-FACP1 | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0129 | PM - MONTHLY FIRE ALARM CONTROL PANEL INSPECTION | 1 Months | Preventive maintenance | IBW-ROUTE-0129 | 19 | E-00000885 | CHARGER, BATTERY, FACP, PERSONNEL BLDG 02612-CHRG-FACP2 | [ ] Check all connections for tightness - Tighten connections/terminals. |
[ ] Check Backup Power Supply Battery for fluid levels(if applicable) - service as needed
| [ ] Check Battery Charging Voltage 27-27.5 - service as needed | IBW-INSTRUMENT | VEI | ||||||||
| Lift Stations | IBW-PM-0137 | PM - MONTHLY GCPS & HPS SURGE ARRESTERS TANKS O&M SERVICE | 1 Months | Preventive maintenance | IBW-ROUTE-0137 | 4 | E-00000045 | TANK 1, SURGE, GCPS 04108-SA1 | O&M manual - Area 13 Canyon Collectors & Lift Stations. Refer to pdf pages 143 or 157; O&M pages 5.13-8 or 5.13-24 |
[ ] Inspect all threaded and bolted connections to the vessels to ensure they are secure.
[ ] Check the gage valves for signs of leakage around stem area. Stem packing leakage can often be stopped by tightening the stem packing nut. If leak persists, replace the stem packing.
[ ] Check the gage valves for signs of internal stem leak. Replace stem or renew seat surface as needed.
[ ] Check the gage valves for signs of leakage around stuffing box connection. Replace glass packing as needed. In the event of improper packing compression, leakage can be stopped by tightening gage coupling nut.
| [ ] Check the gage valves for signs of internal or external corrosion. Conduct investigation as to the cause of the problem as appropriate. | IBW-MAINT | VHVYEQ | ||||||||
| Lift Stations | IBW-PM-0137 | PM - MONTHLY GCPS & HPS SURGE ARRESTERS TANKS O&M SERVICE | 1 Months | Preventive maintenance | IBW-ROUTE-0137 | 4 | E-00000098 | TANK 2, SURGE, HPS 04309-SA2 | O&M manual - Area 13 Canyon Collectors & Lift Stations. Refer to pdf pages 143 or 157; O&M pages 5.13-8 or 5.13-24 |
[ ] Inspect all threaded and bolted connections to the vessels to ensure they are secure.
[ ] Check the gage valves for signs of leakage around stem area. Stem packing leakage can often be stopped by tightening the stem packing nut. If leak persists, replace the stem packing.
[ ] Check the gage valves for signs of internal stem leak. Replace stem or renew seat surface as needed.
[ ] Check the gage valves for signs of leakage around stuffing box connection. Replace glass packing as needed. In the event of improper packing compression, leakage can be stopped by tightening gage coupling nut.
| [ ] Check the gage valves for signs of internal or external corrosion. Conduct investigation as to the cause of the problem as appropriate. | IBW-MAINT | VHVYEQ | ||||||||
| Lift Stations | IBW-PM-0137 | PM - MONTHLY GCPS & HPS SURGE ARRESTERS TANKS O&M SERVICE | 1 Months | Preventive maintenance | IBW-ROUTE-0137 | 4 | E-00000097 | TANK 1, SURGE, HPS 04308-SA1 | O&M manual - Area 13 Canyon Collectors & Lift Stations. Refer to pdf pages 143 or 157; O&M pages 5.13-8 or 5.13-24 |
[ ] Inspect all threaded and bolted connections to the vessels to ensure they are secure.
[ ] Check the gage valves for signs of leakage around stem area. Stem packing leakage can often be stopped by tightening the stem packing nut. If leak persists, replace the stem packing.
[ ] Check the gage valves for signs of internal stem leak. Replace stem or renew seat surface as needed.
[ ] Check the gage valves for signs of leakage around stuffing box connection. Replace glass packing as needed. In the event of improper packing compression, leakage can be stopped by tightening gage coupling nut.
| [ ] Check the gage valves for signs of internal or external corrosion. Conduct investigation as to the cause of the problem as appropriate. | IBW-MAINT | VHVYEQ | ||||||||
| Lift Stations | IBW-PM-0137 | PM - MONTHLY GCPS & HPS SURGE ARRESTERS TANKS O&M SERVICE | 1 Months | Preventive maintenance | IBW-ROUTE-0137 | 4 | E-00000046 | TANK 2, SURGE, GCPS 04109-SA2 | O&M manual - Area 13 Canyon Collectors & Lift Stations. Refer to pdf pages 143 or 157; O&M pages 5.13-8 or 5.13-24 |
[ ] Inspect all threaded and bolted connections to the vessels to ensure they are secure.
[ ] Check the gage valves for signs of leakage around stem area. Stem packing leakage can often be stopped by tightening the stem packing nut. If leak persists, replace the stem packing.
[ ] Check the gage valves for signs of internal stem leak. Replace stem or renew seat surface as needed.
[ ] Check the gage valves for signs of leakage around stuffing box connection. Replace glass packing as needed. In the event of improper packing compression, leakage can be stopped by tightening gage coupling nut.
| [ ] Check the gage valves for signs of internal or external corrosion. Conduct investigation as to the cause of the problem as appropriate. | IBW-MAINT | VHVYEQ | ||||||||
| WWTP | IBW-PM-0164 | PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0164 | 10 | E-00001292 | PANEL, LCP, HVAC UNIT, PRIMARY SKIMMINGS, PST 00418-HVAC-PSKPS | [ ] Clean HVAC Condensor Coils |
[ ] Clean Inlet Screen To HVAC Units
| [ ] Check Unit For Proper Operation | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0164 | PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0164 | 10 | E-00000732 | PANEL, CONTROL, HVAC UNIT, LIME, SP 02800-HVAC-LS1 | [ ] Clean HVAC Condensor Coils |
[ ] Clean Inlet Screen To HVAC Units
| [ ] Check Unit For Proper Operation | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0164 | PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0164 | 10 | E-00000460 | HVAC UNIT, LCP-ES, EBS 01500-HVAC-LCP-ES | [ ] Clean HVAC Condensor Coils |
[ ] Clean Inlet Screen To HVAC Units
| [ ] Check Unit For Proper Operation | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0164 | PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0164 | 10 | E-00001492 | HVAC UNIT, AFD, CONVEYOR 2, TRUCK LOADING 02851-HVAC-TLC2 | [ ] Clean HVAC Condensor Coils |
[ ] Clean Inlet Screen To HVAC Units
| [ ] Check Unit For Proper Operation | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0164 | PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0164 | 10 | E-00000922 | PANEL, CONTROL, LOCAL, HVAC UNIT, ORPST 00419-HVAC-ORPST | [ ] Clean HVAC Condensor Coils |
[ ] Clean Inlet Screen To HVAC Units
| [ ] Check Unit For Proper Operation | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0164 | PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0164 | 10 | E-00001393 | PANEL, CONTROL, LOCAL, HVAC UNIT, PEB 00620-HVAC-LCP-PEB | [ ] Clean HVAC Condensor Coils |
[ ] Clean Inlet Screen To HVAC Units
| [ ] Check Unit For Proper Operation | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0164 | PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0164 | 10 | E-00000906 | PANEL, CONTROL, LOCAL, HVAC UNIT, ORHW 00350-HVAC-ORHW | [ ] Clean HVAC Condensor Coils |
[ ] Clean Inlet Screen To HVAC Units
| [ ] Check Unit For Proper Operation | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0164 | PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0164 | 10 | E-00000963 | PANEL, CONTROL, LOCAL, HVAC UNIT, ORUSS 02250-HVAC-ORUSS | [ ] Clean HVAC Condensor Coils |
[ ] Clean Inlet Screen To HVAC Units
| [ ] Check Unit For Proper Operation | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0164 | PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0164 | 10 | E-00000936 | PANEL, CONTROL, LOCAL, HVAC UNIT 2, ORSP 03700-HVAC-ORSP2 | [ ] Clean HVAC Condensor Coils |
[ ] Clean Inlet Screen To HVAC Units
| [ ] Check Unit For Proper Operation | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0164 | PM - QUARTERLY INSTRUMENTATION CABINET HVAC UNIT INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0164 | 10 | E-00000935 | PANEL, CONTROL, LOCAL, HVAC UNIT 1, ORSP 03700-HVAC-ORSP1 | [ ] Clean HVAC Condensor Coils |
[ ] Clean Inlet Screen To HVAC Units
| [ ] Check Unit For Proper Operation | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0173 | PM - QUARTERLY ORSP CHEMICAL PUMP INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0173 | 4 | E-00000707 | PUMP 14, METERING, CAUSTIC, ORSP 03727-ORMP14 | [ ] Check Hydraulic fluid levels on Pulsar Series 25 Pulsafeeders - Service If Low Or Contaminated with 7H Hydraulic Fluid. |
[ ] Check Oil Level In Series 680 and 880 pumps - Service If Low Or Contaminated with ISO GST 68.
[ ] Check Intermediate Chamber For Proper Glycol Levels: (Only If A Leak Is Indicated Or Pump Efficiency Is Low) ** Insure That The Pump Piston Stroke Is All The Way Back Before Removing Bolt.
Otherwise Pump Will Have To Be Re-Timed.
[ ] Torque Bolts On Pump Head To Proper Ft-Lbs - Refer To O&M Manuals For Proper Settings.
** Do Not Overtighten Bolts Or You Will Stretch The Bolt Hole Threads.
[ ] Check Pressure On Pulsation Dampner - Service If Low Torque Location Model "Reagent Head (Ft-Lb)" "Tie-Bar (In-Lb)" ORSP NaOcl Pump 880 5.9 9.3 ORSP NaOh Pump 680 5.8 12.2
| ORSP H2SO4 Pump 680 5.8 12.2 | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0173 | PM - QUARTERLY ORSP CHEMICAL PUMP INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0173 | 4 | E-00000711 | PUMP 15, METERING, SODIUM HYPOCHLORITE, ORSP 03731-ORMP15 | [ ] Check Hydraulic fluid levels on Pulsar Series 25 Pulsafeeders - Service If Low Or Contaminated with 7H Hydraulic Fluid. |
[ ] Check Oil Level In Series 680 and 880 pumps - Service If Low Or Contaminated with ISO GST 68.
[ ] Check Intermediate Chamber For Proper Glycol Levels: (Only If A Leak Is Indicated Or Pump Efficiency Is Low) ** Insure That The Pump Piston Stroke Is All The Way Back Before Removing Bolt.
Otherwise Pump Will Have To Be Re-Timed.
[ ] Torque Bolts On Pump Head To Proper Ft-Lbs - Refer To O&M Manuals For Proper Settings.
** Do Not Overtighten Bolts Or You Will Stretch The Bolt Hole Threads.
[ ] Check Pressure On Pulsation Dampner - Service If Low Torque Location Model "Reagent Head (Ft-Lb)" "Tie-Bar (In-Lb)" ORSP NaOcl Pump 880 5.9 9.3 ORSP NaOh Pump 680 5.8 12.2
| ORSP H2SO4 Pump 680 5.8 12.2 | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0173 | PM - QUARTERLY ORSP CHEMICAL PUMP INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0173 | 4 | E-00000712 | PUMP 16, METERING, SODIUM HYPOCHLORITE, ORSP 03732-ORMP16 | [ ] Check Hydraulic fluid levels on Pulsar Series 25 Pulsafeeders - Service If Low Or Contaminated with 7H Hydraulic Fluid. |
[ ] Check Oil Level In Series 680 and 880 pumps - Service If Low Or Contaminated with ISO GST 68.
[ ] Check Intermediate Chamber For Proper Glycol Levels: (Only If A Leak Is Indicated Or Pump Efficiency Is Low) ** Insure That The Pump Piston Stroke Is All The Way Back Before Removing Bolt.
Otherwise Pump Will Have To Be Re-Timed.
[ ] Torque Bolts On Pump Head To Proper Ft-Lbs - Refer To O&M Manuals For Proper Settings.
** Do Not Overtighten Bolts Or You Will Stretch The Bolt Hole Threads.
[ ] Check Pressure On Pulsation Dampner - Service If Low Torque Location Model "Reagent Head (Ft-Lb)" "Tie-Bar (In-Lb)" ORSP NaOcl Pump 880 5.9 9.3 ORSP NaOh Pump 680 5.8 12.2
| ORSP H2SO4 Pump 680 5.8 12.2 | IBW-MAINT | VMECH | ||||||||
| WWTP | IBW-PM-0173 | PM - QUARTERLY ORSP CHEMICAL PUMP INSPECTION | 3 Months | Preventive maintenance | IBW-ROUTE-0173 | 4 | E-00000706 | PUMP 13, METERING, CAUSTIC, ORSP 03726-ORMP13 | [ ] Check Hydraulic fluid levels on Pulsar Series 25 Pulsafeeders - Service If Low Or Contaminated with 7H Hydraulic Fluid. |
[ ] Check Oil Level In Series 680 and 880 pumps - Service If Low Or Contaminated with ISO GST 68.
[ ] Check Intermediate Chamber For Proper Glycol Levels: (Only If A Leak Is Indicated Or Pump…