Concrete Reinforcement Specification for Bristol Borough CDBG Curb Ramp Program
This is a technical specification document for concrete reinforcement materials and installation procedures for the 2026 Bristol Borough CDBG Curb Ramp Program in Bucks County, Pennsylvania. The specification establishes requirements for reinforcing steel bars, wire fabric, and accessories used in cast-in-place concrete work as part of the borough's ADA/PennDOT compliant curb ramp infrastructure project. The specification mandates the use of ASTM A615 deformed billet steel bars with 60 ksi yield grade in unfinished condition and ASTM A185 welded steel wire fabric in flat sheets for reinforcement. All reinforcing steel accessories, including tie wire, chairs, bolsters, and bar supports, must meet specified standards with plastic-coated steel types required for weather-exposed concrete surfaces. Fabrication must comply with the Concrete Reinforcing Steel Institute (CRSI) Manual of Practice, and reinforcement placement, support, and security must strictly conform to design specifications without deviation from required positions, including adherence to ACI 318 code requirements for concrete cover.
Quality assurance requirements mandate that all work be performed in accordance with CRSI standards 63 and 65, ACI 301 and ACI 318 building codes, and that design be conducted under the direct supervision of a Professional Structural Engineer licensed in Pennsylvania. Contractors must provide the engineer with access to fabrication plants for inspection purposes and submit notification of shop fabrication schedules. Welders employed on the project must submit AWS qualification certificates dated within the previous 12 months. Documentation requirements include maintaining copies of applicable standards and codes on site and submitting all required certifications and inspection notifications in advance of construction activities.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONCRETE REINFORCEMENT
03 20 00-1
SECTION 03 20 00
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Reinforcing steel bars, wire fabric and accessories for cast-in-place concrete.
1.02 RELATED SECTIONS
A. Related Work Specified Elsewhere.
1. This section not used.
1.03 REFERENCES
A. ACI 301 - Structural Concrete for Buildings.
B. ACI 318 - Building Code Requirements for Reinforced Concrete.
C. ASTM A185 - Welded Steel Wire Fabric for Concrete Reinforcement.
D. ASTM A615 - Deformed and Plain Billet Steel Bars for Concrete Reinforcement.
E. ASTM A775 - Epoxy-Coated Reinforcing Steel Bars.
F. ASTM D3963 - Epoxy-Coated Reinforcing Steel.
G. CRSI - Concrete Reinforcing Steel Institute - Manual of Practice.
H. CRSI 63 - Recommended Practice for Placing Reinforcing Bars.
I. CRSI 65 - Recommended Practice for Placing Bar Supports, Specifications and Nomenclature.
1.04 SUBMITTALS FOR REVIEW
A. Section 01 33 00 - Submittals: Procedures for submittals.
1.05 QUALITY ASSURANCE
A. Perform Work in accordance with CRSI 63, 65 and Manual of Practice, ACI 301, and ACI 318.
Maintain one copy of each document on site.
B. Provide Engineer with access to fabrication plant to facilitate inspection of reinforcement. Provide notification of commencement and duration of shop fabrication in sufficient time to allow inspection.
C. Design reinforcement under direct supervision of a Professional Structural Engineer experienced in design of this Work and licensed in the Commonwealth of Pennsylvania.
D. Welders: Certificates: Submit under provisions of Section 01 40 00 Manufacturer’s Certificates, certifying welders employed on the Work, verifying AWS qualification within the previous 12 months.
PART 2 PRODUCTS
2.01 REINFORCEMENT
A. Reinforcing Steel: ASTM A615, 60 ksi yield grade; deformed billet steel bars, unfinished.
B. Welded Steel Wire Fabric: ASTM A185 Plain Type in flat sheets, unfinished.
2.02 ACCESSORIES
A. Tie Wire: Minimum 16 gage annealed type, epoxy coated.
B. Chairs, Bolsters, Bar Supports, Spacers: Sized and shaped for strength and support of reinforcement during concrete placement conditions.
C. Special Chairs, Bolsters, Bar Supports, Spacers Adjacent to Weather Exposed Concrete Surfaces:
Plastic coated steel type; size and shape as required.
2.03 FABRICATION
03 20 00-2
A. Fabricate concrete reinforcing in accordance with CRSI Manual of Practice.
B. Locate reinforcing splices not indicated on drawings, at point of minimum stress.
PART 3 EXECUTION
3.01 PLACEMENT
A. Place, support and secure reinforcement against displacement. Do not deviate from required position.
B. Do not displace or damage vapor barrier.
C. Accommodate placement of formed openings.
D. Conform to Act 318 code for concrete cover over reinforcement.
END OF SECTION