48-Sec 32 17 26 - ADA DETECTABLE WARNING SURFACE.pdf
PDF 98 KB Posted
- Attached to
- 2026 Bristol Borough CDBG Curb Ramp Program
- Solicitation number
- Not on record
- Issued by
- Bucks County, Brodheadsville CDP, Pennsylvania
About this file
This is a technical specification document for ADA Detectable Warning Surface installation, issued by Bristol Borough in Bucks County, Pennsylvania, as part of the 2026 CDBG Curb Ramp Program. The project requires installation of ADA/PennDOT compliant detectable warning surfaces at specified locations within the borough. The work involves polymer composite detectable warning tiles composed of epoxy polymers with aluminum oxide particles in truncated domes, manufactured by a PennDOT Bulletin 15 approved manufacturer. Tiles must be Brick Red in color with dimensions of 24 inches nominal width, 0.1875 inches face thickness with ±5 percent tolerance, and 0.5 percent maximum edge warpage. Installation shall be performed according to manufacturer recommendations in a manner that does not create tripping hazards. Tiles must be protected against damage during the construction period and are guaranteed in writing for five years from final completion, including coverage for defective work, breakage, deformation, and loosening.
Contractors selected for this work must demonstrate a minimum of five years of experience with tile installations and submit qualifications documentation including a list of similar projects and superintendent resumes for approval. The installer's qualifications must be accepted before work commences. All materials must be certified to meet or exceed designated specifications and comply with ADA and PennDOT regulations. Installation costs and pricing terms are not specified in this technical specification document, as pricing would be submitted separately in the contractor's bid proposal. The project is funded through Community Development Block Grant (CDBG) resources and requires compliance with federal labor standards including Davis-Bacon wage rates, performance and payment bonds, and various contractor certifications as outlined in the overall bid solicitation.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADA DETECTABLE WARNING TILES
32 17 26-1
SECTION 32 17 26
ADA DETECTABLE WARNING SURFACE
PART 1 GENERAL
1.01 DESCRIPTION OF WORK
A. This Work is the installation of ADA/PennDOT compliant detectable warning surfaces (DWS) at locations specified in the field and on the drawings.
1.02 SUBMITTALS
A. Certifications: Submit certifications that all tiles will meet or exceed designated specifications.
B. Qualifications of Installer:
1. Installer shall have a minimum of five (5) years of experience with tile installations.
2. Installer shall submit for approval, a list of projects similar in nature and size that establishes his/her ability to complete this project. A resume for the project superintendent should be submitted to establish his/her ability to complete the project. If for any reason, the qualifications are not acceptable, work shall not commence until an acceptable installer is found.
PART 2 PRODUCTS
2.01 DETECTABLE WARNING TILES
A. Detectable warning tiles to be manufactured by a PennDOT Bulletin 15 approved manufacturer.
1. Detectable Warning Surfaces shall be compliant with ADA and PennDOT regulations.
2. Detectable Warning Surfaces shall be of the Polymer Composite type composed of epoxy polymers employing aluminum oxide particles in the truncated domes.
4. Detectable warning surface shall be of the embedded cast-in-place type, Brick Red color.
3. Dimensions: Detectable Warning Surfaces shall be held within the following dimensions and tolerances:
Width: 24” nominal
Face Thickness: 0.1875 +/- 5% max.
Warpage of Edge: 0.5% max.
Length: as required to be provided across the full width of the ramp at the grade break near the street edge
B. Color shall be Brick Red.
C. Detectable warning surface shall be guaranteed in writing for a period of five years from date
ADA DETECTABLE WARNING TILES
32 17 26-2 of final completion. The guarantee must include defective work, breakage, deformation, and loosening of tiles.
PART 3 EXECUTION
3.01 INSTALLATION
A. Installation shall be performed according to manufacturer’s recommendations.
B. Tile shall be installed in a manner which does not create a tripping hazard.
3.02 CLEANING AND PROTECTION
A. Protect tiles against damage during construction period to comply with manufacturer’s specification.
END OF SECTION