589A6-21-700.LEHRM.ASI-001.B90.20220419.pdf
PDF 7 MB Posted
- Solicitation number
- 36C77622R0061
About this file
This federal solicitation seeks proposals for a telecommunications cabling replacement project at the VA Medical Campus in Leavenworth, Kansas. The project involves replacing all telecommunications cable, outlets, and associated equipment in multiple buildings to prepare for an Electronic Health Record modernization. Proposers will replace all copper cabling with CAT6a and install new fiber optic cabling. Additional capacity of 15% must be provided. New patch panels, racks, and ladder racks will also be installed in telecom rooms. The project includes adding new computer room air conditioning and electrical infrastructure. Proposals are due by the date listed in the solicitation.
View the file
Other files
Show 40 more
Latest 50 of 67 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
STAMP
B
IM
/5
A
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e a t L e a v e n w o rt h K
S V
A M
C /5
A
-2
-7
.L E
H R
M .B
.8 .9
.9
.M
E P
.r v t
/1
/2
:3
:1
P
M
90G-001
DRAWING INDEX 589A6-21-700
B88/89/90/91
01/19/2022 M. PERKINS K.
HUTCHINSON
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
4101 4TH ST TRAFFICWAY, LEAVENWORTH, KS 66048
- DRAWING INDEX -
SHEET NUMBER SHEET NAME INCLUDED IN 35% SD INCLUDED IN 65% DD INCLUDED IN 95% CD
INCLUDED IN FINAL BID
DOCUMENTS
ISSUED FOR
CONSTRUCTION
ELECTRICAL
90E-001 ELECTRICAL ABBREVIATIONS AND SYMBOLS Yes Yes Yes Yes Yes
88E-101 ELECTRICAL PLANS - FIRST LEVEL - B88 No No No Yes Yes
88E-102 ELECTRICAL PLANS - SECOND LEVEL - B88 No No No Yes Yes
88E-103 ELECTRICAL PLANS - THIRD LEVEL - B88 No No No Yes Yes
88E-104 ELECTRICAL PLANS - FOUTH LEVEL - B88 No No No Yes Yes
88E-105 ELECTRICAL PLANS - FIFTH LEVEL - B88 No No No Yes Yes
88E-106 ELECTRICAL PLANS - SIXTH LEVEL - B88 No No No Yes Yes
89E-101 ELECTRICAL PLANS - FIRST LEVEL - B89 No No No Yes Yes
89E-102 ELECTRICAL PLANS - SECOND LEVEL - B89 No No No Yes Yes
90E-100B ELECTRICAL PLANS - BASEMENT LEVEL - B90B No No No Yes Yes
90E-101A ELECTRICAL PLANS - FIRST LEVEL - B90A No No No Yes Yes
90E-101B ELECTRICAL PLANS - FIRST LEVEL - B90B No No No Yes Yes
90E-102A ELECTRICAL PLANS - SECOND LEVEL - B90A No No No Yes Yes
90E-102B ELECTRICAL PLANS - SECOND LEVEL - B90B No No No Yes Yes
90E-103A ELECTRICAL PLANS - THIRD LEVEL - B90A No No No Yes Yes
90E-103B ELECTRICAL PLANS - THIRD LEVEL - B90B No No No Yes Yes
90E-104A ELECTRICAL PLANS - FOURTH LEVEL - B90A No No No Yes Yes
90E-104B ELECTRICAL PLANS - FOURTH LEVEL - B90B No No No Yes Yes
90E-105A ELECTRICAL PLANS - FIFTH LEVEL - B90A No No No Yes Yes
90E-105B ELECTRICAL PLANS - FIFTH LEVEL - B90B No No No Yes Yes
90E-106A ELECTRICAL PLANS - SIXTH LEVEL - B90A No No No Yes Yes
90E-106B ELECTRICAL PLANS - SIXTH LEVEL - B90B No No No Yes Yes
91E-101A ELECTRICAL PLANS - FIRST LEVEL - B91A No No No Yes Yes
91E-101B ELECTRICAL PLANS - FIRST LEVEL - B91B No No No Yes Yes
91E-102A ELECTRICAL PLANS - SECOND LEVEL - B91A No No No Yes Yes
91E-102B ELECTRICAL PLANS - SECOND LEVEL - B91B No No No Yes Yes
91E-103A ELECTRICAL PLANS - THIRD LEVEL - B91A No No No Yes Yes
91E-103B ELECTRICAL PLANS - THIRD LEVEL - B91B No No No Yes Yes
91E-104A ELECTRICAL PLANS - FOURTH LEVEL - B91A No No No Yes Yes
91E-104B ELECTRICAL PLANS - FOURTH LEVEL - B91B No No No Yes Yes
91E-105A ELECTRICAL PLANS - FIFTH LEVEL - B91A No No No Yes Yes
91E-105B ELECTRICAL PLANS - FIFTH LEVEL - B91B No No No Yes Yes
91E-106A ELECTRICAL PLANS - SIXTH LEVEL - B91A No No No Yes Yes
91E-106B ELECTRICAL PLANS - SIXTH LEVEL - B91B No No No Yes Yes
88E-401 ELECTRICAL ENLARGED PLANS - B88 No No Yes Yes Yes
88E-402 ELECTRICAL ENLARGED PLANS - B88 No No Yes Yes Yes
88E-403 LIGHTING ELECTRICAL ENLARGED PLANS - B88 No No Yes Yes Yes
88E-404 ELECTRICAL ENLARGED PLANS - B88 No No Yes Yes Yes
88E-405 LIGHTING ELECTRICAL ENLARGED PLANS - B88 No No Yes Yes Yes
90E-406 ELECTRICAL ENLARGED PLANS - B90 No No Yes Yes Yes
90E-407 LIGHTING ELECTRICAL ENLARGED PLANS - B90 No No Yes Yes Yes
90E-408 ELECTRICAL ENLARGED PLANS - B90 No No Yes Yes Yes
90E-409 LIGHTING ELECTRICAL ENLARGED PLANS - B90 No No Yes Yes Yes
91E-410 ELECTRICAL ENLARGED PLANS - B91 No No Yes Yes Yes
91E-411 LIGHTING ELECTRICAL ENLARGED PLANS - B91 No No Yes Yes Yes
91E-412 ELECTRICAL ENLARGED PLANS - B91 No No Yes Yes Yes
91E-413 LIGHTING ELECTRICAL ENLARGED PLANS - B91 No No Yes Yes Yes
91E-414 ELECTRICAL ENLARGED PLANS - B91 No No Yes Yes Yes
90E-501 ELECTRICAL DETAILS Yes Yes Yes Yes Yes
88E-601 B88 ELECTRICAL ONE-LINE DIAGRAMS Yes Yes Yes Yes Yes
90E-602 B90 ELECTRICAL ONE-LINE DIAGRAMS Yes Yes Yes Yes Yes
91E-603 B91 ELECTRICAL ONE-LINE DIAGRAMS Yes Yes Yes Yes Yes
90E-701 ELECTRICAL SCHEDULES Yes Yes Yes Yes Yes
90E-702 ELECTRICAL SCHEDULES Yes Yes Yes Yes Yes
90E-703 ELECTRICAL SCHEDULES Yes Yes Yes Yes Yes
90E-704 ELECTRICAL SCHEDULES Yes Yes Yes Yes Yes
90E-705 ELECTRICAL SCHEDULES Yes Yes Yes Yes Yes
90E-706 ELECTRICAL SCHEDULES Yes Yes Yes Yes Yes
90E-707 ELECTRICAL SCHEDULES Yes Yes Yes Yes Yes
90E-708 ELECTRICAL SCHEDULES Yes Yes Yes Yes Yes
90E-709 ELECTRICAL SCHEDULES No No No No Yes
90E-901 ELECTRICAL CUTSHEETS & BASIS OF DESIGN Yes Yes Yes Yes Yes
TELECOMMUNICATION
90T-001 TELECOMMUNICATION ABBREVIATIONS AND SYMBOLS Yes Yes Yes Yes Yes
88T-101 TELECOMMUNICATION PLAN - FIRST LEVEL - B88 Yes Yes Yes Yes Yes
88T-102 TELECOMMUNICATION PLANS - SECOND LEVEL - B88 Yes Yes Yes Yes Yes
88T-103 TELECOMMUNICATION PLANS - THIRD LEVEL - B88 Yes Yes Yes Yes Yes
88T-104 TELECOMMUNICATION PLANS - FOURTH LEVEL - B88 Yes Yes Yes Yes Yes
88T-105 TELECOMMUNIATION PLANS - FIFTH LEVEL - B88 Yes Yes Yes Yes Yes
88T-106 TELECOMMUNICATION PLANS - SIXTH LEVEL - B88 Yes Yes Yes Yes Yes
88T-400 TELECOMMUNICATION ENLARGED PLANS - B88 Yes Yes Yes Yes Yes
89T-101 TELECOMMUNICATION PLANS - FIRST LEVEL - B89 Yes Yes Yes Yes Yes
89T-102 TELECOMMUNICATION PLANS - SECOND LEVEL - B89 Yes Yes Yes Yes Yes
90T-100A TELECOMMUNICATION PLANS - BASEMENT LEVEL - B90A Yes Yes Yes Yes Yes
90T-100B TELECOMMUNICATION PLANS - BASEMENT LEVEL - B90B Yes Yes Yes Yes Yes
90T-101A TELECOMMUNICATION PLANS - FIRST LEVEL - B90A Yes Yes Yes Yes Yes
90T-101B TELECOMMUNICATION PLANS - FIRST LEVEL - B90B Yes Yes Yes Yes Yes
90T-102A TELECOMMUNICATION PLANS - SECOND LEVEL - B90A Yes Yes Yes Yes Yes
90T-102B TELECOMMUNICATION PLANS - SECOND LEVEL - B90B Yes Yes Yes Yes Yes
90T-103A TELECOMMUNICATION PLANS - THIRD LEVEL - B90A Yes Yes Yes Yes Yes
90T-103B TELECOMMUNICATION PLANS - THIRD LEVEL - B90B Yes Yes Yes Yes Yes
90T-104A TELECOMMUNICATION PLANS - FOURTH LEVEL - B90A Yes Yes Yes Yes Yes
90T-104B TELECOMMUNICATION PLANS - FOURTH LEVEL - B90B Yes Yes Yes Yes Yes
90T-105A TELECOMMUNICATION PLANS - FIFTH LEVEL - B90A Yes Yes Yes Yes Yes
90T-105B TELECOMMUNICATION PLAN - FIFTH LEVEL - B90B Yes Yes Yes Yes Yes
90T-106A TELECOMMUNICATION PLANS - SIXTH LEVEL - B90A Yes Yes Yes Yes Yes
90T-106B TELECOMMUNICATION PLANS - SIXTH LEVEL - B90B Yes Yes Yes Yes Yes
91T-101A TELECOMMUNICATION PLANS - FIRST LEVEL - B91A Yes Yes Yes Yes Yes
91T-101B TELECOMMUNICATION PLANS - FIRST LEVEL - B91B Yes Yes Yes Yes Yes
91T-102A TELECOMMUNICATION PLANS - SECOND LEVEL - B91A Yes Yes Yes Yes Yes
91T-102B TELECOMMUNICATION PLANS - SECOND LEVEL - B91B Yes Yes Yes Yes Yes
91T-103A TELECOMMUNICATION PLAN - THIRD LEVEL - B91A Yes Yes Yes Yes Yes
91T-103B TELECOMMUNICATION PLANS - THIRD LEVEL - B91B Yes Yes Yes Yes Yes
91T-104A TELECOMMUNICATION PLANS - FOURTH LEVEL - B91A Yes Yes Yes Yes Yes
91T-104B TELECOMMUNICATION PLANS - FOURTH LEVEL - B91B Yes Yes Yes Yes Yes
91T-105A TELECOMMUNICATION PLANS - FIFTH LEVEL - B91A Yes Yes Yes Yes Yes
91T-105B TELECOMMUNICATION PLANS- FIFTH LEVEL - B91B Yes Yes Yes Yes Yes
91T-106A TELECOMMUNICATION PLANS - SIXTH LEVEL - B91A Yes Yes Yes Yes Yes
91T-106B TELECOMMUNICATION PLANS - SIXTH LEVEL - B91B Yes Yes Yes Yes Yes
90T-501 TELECOMMUNICATION DETAILS Yes Yes Yes Yes Yes
90T-502 TELECOMMUNICATION ROOM OIT TEMPLATE DETAILS Yes Yes Yes Yes Yes
90T-503 TELECOMMUNICATION ROOM OIT TEMPLATE DETAILS Yes Yes Yes Yes Yes
90T-601 TELECOMMUNICATIONS RISER DIAGRAMS Yes Yes Yes Yes Yes
90T-602 TELECOMMUNICATIONS FIBER RISER DIAGRAM - NEW Yes Yes Yes Yes Yes
90T-603 TELECOMMUNICATION RACK ELEVATIONS Yes Yes Yes Yes Yes
90T-604 TELECOMMUNICATION RACK ELEVATIONS Yes Yes Yes Yes Yes
88T-701 TELECOMMUNICATION SCHEDULES - BUILDING 88 Yes Yes Yes Yes Yes
88T-702 TELECOMMUNICATION SCHEDULES - BUILDING 88 & 89 Yes Yes
90T-701 TELECOMMUNICATION SCHEDULES - BUILDING 90 Yes Yes Yes Yes Yes
90T-702 TELECOMMUNICATION SCHEDULES - BUILDING 90 Yes Yes Yes Yes Yes
90T-703 TELECOMMUNICATION SCHEDULES - BUILDING 90 Yes Yes Yes Yes Yes
91T-701 TELECOMMUNICATION SCHEDULES - BUILDING 91 Yes Yes Yes Yes Yes
91T-702 TELECOMMUNICATION SCHEDULES - BUILDING 91 Yes Yes Yes Yes Yes
91T-703 TELECOMMUNICATION SCHEDULES - BUILDING 91 Yes Yes Yes Yes Yes
90T-901 TELECOMMUNICATION CUTSHEETS & BASIS OF DESIGN Yes Yes Yes Yes Yes
90T-902 TELECOMMUNICATION CUTSHEETS & BASIS OF DESIGN Yes Yes Yes Yes Yes
REFERENCE
90R-900 PHOTO REFERENCES Yes Yes Yes Yes Yes
Grand total: 180
- DRAWING INDEX -
SHEET NUMBER SHEET NAME INCLUDED IN 35% SD INCLUDED IN 65% DD INCLUDED IN 95% CD
INCLUDED IN FINAL BID
DOCUMENTS
ISSUED FOR
CONSTRUCTION
GENERAL
90G-000 COVER SHEET Yes Yes Yes Yes Yes
90G-001 DRAWING INDEX Yes Yes Yes Yes Yes
90G-010 GENERAL PROJECT NOTES Yes Yes Yes Yes Yes
90G-011 GENERAL INFECTION CONTROL NOTES AND SYMBOLS Yes Yes Yes Yes Yes
90G-012 GENERAL INDOOR AIR QUALITY NOTES Yes Yes Yes Yes Yes
ARCHITECTURAL
90A-001 SYMBOLS, & GENERAL NOTES Yes Yes Yes Yes Yes
90A-400 ARCHITECTURAL ENLARGED VIEWS - BASEMENT LEVEL No No Yes Yes Yes
90A-401 ARCHITECTURAL ENLARGED VIEWS - FIRST LEVEL No No Yes Yes Yes
90A-402 ARCHITECTURAL ENLARGED VIEWS - SECOND LEVEL No No Yes Yes Yes
90A-403 ARCHITECTURAL ENLARGED VIEWS - THIRD LEVEL No No Yes Yes Yes
90A-404 ARCHITECTURAL ENLARGED VIEWS - FOURTH LEVEL No No Yes Yes Yes
90A-405 ARCHITECTURAL ENLARGED VIEWS - FIFTH LEVEL No No Yes Yes Yes
90A-406 ARCHTECTURAL ENLARGED VIEWS - SIXTH LEVEL No No Yes Yes Yes
90A-501 ARCHITECTURAL ROOF PLAN & DETAILS No No Yes Yes Yes
90A-511 ARCHITECTURAL PARTITION AND FRAMING DETAILS No No Yes Yes Yes
90A-512 ARCHITECTURAL PARTITION HEAD DETAILS No No Yes Yes Yes
90A-531 ARCHITECTURAL CEILING DETAILS No No Yes Yes Yes
INTERIORS
90IN101 INTERIOR FINISH PLAN, SIGNAGE & SCHEDULES No No Yes Yes Yes
FIRE PROTECTION
90FX001 FIRE PROTECTION ABBREVIATIONS, SYMBOLS, AND DETAILS Yes Yes Yes Yes Yes
90FX400 FIRE PROTECTION ENLARGED PLANS - BASEMENT LEVEL No No Yes Yes Yes
90FX401 FIRE PROTECTION ENLARGED PLANS - FIRST LEVEL No No Yes Yes Yes
90FX402 FIRE PROTECTION ENLARGED PLANS - SECOND LEVEL No No Yes Yes Yes
90FX403 FIRE PROTECTION ENLARGED PLANS - THIRD LEVEL No No Yes Yes Yes
90FX404 FIRE PROTECTION ENLARGED PLANS - FOURTH LEVEL No No Yes Yes Yes
90FX405 FIRE PROTECTION ENLARGED PLANS - FIFTH LEVEL No No Yes Yes Yes
90FX406 FIRE PROTECTION ENLARGED PLANS - SIXTH LEVEL No No Yes Yes Yes
90FX901 FIRE PROTECTION CUTSHEETS & BASIS OF DESIGN Yes Yes Yes Yes Yes
MECHANICAL
90M-001 MECHANICAL ABBREVIATIONS AND SYMBOLS Yes Yes Yes Yes Yes
88M-100 MECHANICAL PLANS - PIPE SPACE - B88 No No No Yes Yes
88M-101 MECHANICAL PLANS - FIRST LEVEL - B88 Yes Yes Yes Yes Yes
88M-102 MECHANICAL PLANS - SECOND LEVEL - B88 Yes Yes Yes Yes Yes
88M-103 MECHANICAL PLANS - THIRD LEVEL - B88 Yes Yes Yes Yes Yes
88M-104 MECHANICAL PLANS - FOURTH LEVEL - B88 Yes Yes Yes Yes Yes
88M-105 MECHANICAL PLANS - FIFTH LEVEL - B88 Yes Yes Yes Yes Yes
88M-106 MECHANICAL PLANS - SIXTH LEVEL - B88 Yes Yes Yes Yes Yes
88M-401 MECHANICAL ENLARGED PLANS - B88 No No No Yes Yes
89M-101 MECHANICAL PLANS - FIRST LEVEL - B89 No No No Yes Yes
90M-100AB MECHANICAL PLANS - PIPE SPACE - B90AB No No No Yes Yes
90M-100B MECHANICAL PLANS - BASEMENT LEVEL - B90B No No No Yes Yes
90M-101A MECHANICAL PLANS - FIRST LEVEL - B90A No No No Yes Yes
90M-101B MECHANICAL PLANS - FIRST LEVEL - B90B No No No Yes Yes
90M-102A MECHANICAL PLANS - SECOND LEVEL - B90A No No No Yes Yes
90M-102B MECHANICAL PLANS - SECOND LEVEL - B90B No No No Yes Yes
90M-103A MECHANICAL PLANS - THIRD LEVEL - B90A No No No Yes Yes
90M-103B MECHANICAL PLANS - THIRD LEVEL - B90B No No No Yes Yes
90M-104A MECHANICAL PLANS - FOURTH LEVEL - B90A No No No Yes Yes
90M-104B MECHANICAL PLANS - FOURTH LEVEL - B90B No No No Yes Yes
90M-105A MECHANICAL PLANS - FIFTH LEVEL - B90A No No No Yes Yes
90M-105B MECHANICAL PLANS - FIFTH LEVEL - B90B No No No Yes Yes
90M-106A MECHANICAL PLANS - SIXTH LEVEL - B90A No No No Yes Yes
91M-100AB MECHANICAL PLANS - PIPE SPACE - B91AB No No Yes Yes Yes
91M-101A MECHANICAL PLANS - FIRST LEVEL - B91A No No No Yes Yes
91M-101B MECHANICAL PLANS - FIRST LEVEL - B91B No No No Yes Yes
91M-102B MECHANICAL PLANS - SECOND LEVEL - B91B No No No Yes Yes
91M-103B MECHANICAL PLANS - THIRD LEVEL - B91B No No No Yes Yes
91M-104B MECHANICAL PLANS - FOURTH LEVEL - B91B No No No Yes Yes
91M-105B MECHANICAL PLANS - FIFTH LEVEL - B91B No No No Yes Yes
91M-106B MECHANICAL PLANS - SIXTH LEVEL - B91B No No No Yes Yes
90M-501 MECHANICAL DETAILS Yes Yes Yes Yes Yes
90M-601 MECHANICAL CHILLED WATER PIPING RISER DIAGRAM No No Yes Yes Yes
90M-701 MECHANICAL SECHEDULES No No No Yes Yes
90M-801 MECHANICAL CONTROL SYMBOL LEGEND AND ABBREVIATIONS No No Yes Yes Yes
90M-802 MECHANICAL CONTROL DIAGRAMS No No Yes Yes Yes
90M-901 MECHANICAL CUTSHEETS & BASIS OF DESIGN Yes Yes Yes Yes Yes
Revisions: Date:
ASI-001 04/18/22
/18
/20
04/18/2022
UP
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW TELECOM ROOMS SHALL BE SMOKE RATED AND COMPLY WITH
THE LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531.
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
ACOUSTICAL OR RATED
FLEXIBLE SEALANT
FLOOR LINE
ADD ONE LAYER OF 5/8" GWB,
ONE-SIDE WITH APPROVED UL
SETTING COMPOUND BETWEEN
LAYERS AND FASTENED TO
WALL AS REQUIRED, AT
EXISTING GWB WALL
ASSEMBLIES
STRUCTURAL DECK
EXISTING METAL STUDS AND
BATT INSULATION TO REMAIN
A/C GRADE, 3/4" FIRE-TREATED
PLYWOOD TO 8'-0" ABOVE FINISHED
FLOOR, ADHERED TO CONCRETE AT
EXISTING CONCRETE WALL
ASSEMBLIES
BOTTOM OF PLYWOOD
TO BE AT 12" AFF
UL DESIGN V497
1-HOUR PARTITION RATED FROM BOTH SIDES
EXISTING GWB OR
CONCRETE WALL
ASSEMBLY, WHERE OCCURS
SIDE OF
EXISTING
ROOM OR
CORRIDOR TO
REMAIN
90A-512
D5
90A-512
B5
ACOUSTICAL OR RATED
SEALANT BOTH SIDES
FLOOR LINE
5/8" GWB BOTH SIDES
SOUND ATTENUATION
BATTS (SAB) PER
SCHEDULE.
CEILING LINE
STRUCTURAL DECK
METAL STUDS, SIZE
PER SCHEDULE
90A-512
D5
A/C GRADE, 3/4" FIRE-
TREATED PLYWOOD TO 8'-0"
ABOVE FINISHED FLOOR
90A-512
B5
AT FIRE RATED
PARTITIONS
AT SMOKE RATED
PARTITIONS
BOTTOM OF PLYWOOD TO
BE AT 12" AFF
F4
TYPICAL FRAME
H E
IG
H
T
2" WIDTH 2"
F5
FRAME TYPE ELEVATIONS DOOR TYPE ELEVATIONS
F
FLUSH
F2
/2
V
A R
IE
S
S E
E P
L A
N
/2
4" 2"
ADJACENT WALL
WHERE OCCURS
SEALANT - EA SIDE &
ALL AROUND, TYP.
HOLLOW METAL
FRAME
WALL - SEE PLAN
FOR TYPE
1/2" 1/2"
VARIES
SEE PLAN
WALL - SEE PLAN
FOR TYPE
SEALANT - EA. SIDE
& ALL AROUND,
TYP.
HOLLOW METAL
FRAME
TELECOM
ROOM
A11
ACTUAL: 141 SF
90A-400
D8
90A-400
D6
B
B
B
B
B
TELECOM
ROOM
A11
ACTUAL: 141 SF
A
(EXT'G VIF)
10'-7 1/4"
(E X
T 'G
V
IF
'-1
1/ 4"
TELECOM
ROOM
A11
141 SF
STORAGE
A11
144 SF
STORAGE
A11
144 SF
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
B
IM
/5
A
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e a t L e a v e n w o rt h
K S
V A
M C
/5
A
-2
-7
.L E
H R
M .B
.8
.9 .9
.A
R C
H .r v t
/1
/2
:2
:1
P
M
90A-400
ARCHITECTURAL ENLARGED VIEWS - BASEMENT
LEVEL
589A6-21-700
B88/89/90/91
01/19/2022 M. Perkins K. McDermott
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
4101 4TH ST TRAFFICWAY, LEAVENWORTH, KS 66048
NOTE: FIRE RESISTANCE TEST FOR ONE HOUR RATED WALLS: UL
U465
(TYPE A) TYPICAL PARTITION
MARK STUD WIDTH PRTN WIDTH DESIGN STC
A4
NOTE: FIRE RESISTANCE TEST FOR TWO HOUR RATED WALLS: UL
V438, UL U411
(TYPE B) TYPICAL PARTITION
MARK STUD WIDTH PRTN WIDTH DESIGN STC
B 2 1/2" 3/4" 45
DOOR AND FRAME SCHEDULE
IDENTIFICATION DIMENSIONS PANEL FRAME DETAIL
FIRE RATING
HARDWARE
NOTESLEVEL ROOM NO. ROOM NAME DOOR NO. W1 H T TYPE MATERIAL FINISH GLAZING UNDERCUT TYPE MATERIAL FINISH HEAD JAMB SILL GROUP ELECTRICAL
BASEMENT A11 TELECOM ROOM A11 3' - 0" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 1 C128 TELECOM ROOM C128 3' - 0" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 1 B106 COMM/BUS
MANAGER
B106A 3' - 4" 7' - 0" WD WD NONE HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 1 B106A TELECOM ROOM B106B 3' - 0" 6' - 8" WD WD NONE HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 1 A129 TELECOM ROOM A129 3' - 0" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 1 B216 TELECOM ROOM B106H 3' - 0" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 2 C228 TELECOM ROOM C228 3' - 6" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 2 A214 TELECOM ROOM A214 3' - 8" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 2 B216 TELECOM ROOM B216 3' - 0" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 3 B341 TELECOM ROOM B341 3' - 0" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 3 A329 TELECOM ROOM A329 3' - 8" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 3 C346 TELECOM ROOM C346 4' - 0" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 3 B341 TELECOM ROOM B106I 3' - 0" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 4 C436 TELECOM ROOM C436 3' - 4" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 4 A419 TELECOM ROOM A419 2' - 8" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 4 B417A TELECOM ROOM B417A 3' - 0" 7' - 0" F WD WD NONE HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 5 A521 TELECOM ROOM A521 3' - 6" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 5 C511 TELECOM ROOM C511 3' - 0" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 5 B504B BIO-MED SERVER
ROOM
B504B 3' - 0" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 6 C622 TELECOM ROOM C622 2' - 8" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 6 A621A TELECOM ROOM A621A 3' - 6" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
LEVEL 6 B623 TELECOM ROOM B623 3' - 6" 7' - 0" F WD WD NONE 3/8" HM PTD 45 MIN HW-SH-3F SEE ELEC
1/4" = 1'-0" B1
WRAPPED FRAME TYPES ELEVATIONS
3" = 1'-0" D3
HOLLOW METAL JAMB DETAIL
3" = 1'-0"
D1
HOLLOW METAL HEAD DETAIL
1 REMOVE EXISTING FLOORING AND WALL BASE.
3 EXISTING WALLS TO BECOME SMOKE RATED. PATCH AND SEAL
ALL PENETRATIONS AS NECESSARY.
4 REMOVE EXISTING ACOUSTICAL CEILING AND LIGHTS. MODIFY
AND/OR PROVIDE ADDITIONAL SUPPORTS AS REQUIRED FOR
EXISTING CEILING ITEMS TO REMAIN.
5 TELECOM ROOM TO BE OPEN TO DECK ABOVE.
6 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE
2A:10B:C FIRE EXTINGUISHER LOCATED NO GREATER THAN 75
FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE
THE NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A
NEW FEC FOR EACH TR IN THE SCOPE OF WORK. SEE
SPECIFICATION 10 44 13.
7 PROVIDE TEMPORARY AIRTIGHT BARRIER AROUND WORK AREA
DURING ANY ACTIVITIES WHICH PRODUCE DUST - TYPICAL
1/32" = 1'-0" F6
BASEMENT REFERENCE PLAN
1/4" = 1'-0" D6
ARCHITECTURAL ENLARGED FLOOR PLAN -
BASEMENT LEVEL - ROOM A11 - DEMO
1/4" = 1'-0"
D8
ARCHITECTURAL ENLARGED FLOOR PLAN -
BASEMENT LEVEL - ROOM A11 - NEW
1/4" = 1'-0" B8
ARCHITECTURAL REFLECTED CEILING PLAN -
BASEMENT LEVEL - A11 - NEW
1/4" = 1'-0"
B6
ARCHITECTURAL REFLECTED CEILING PLAN -
BASEMENT LEVEL - A11 - DEMO
Revisions: Date:
ASI 1 04/13/22
04/18/22
/18
/20
DN
UP
UP
UPUP
DNUP
DN
UP
DN
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW TELECOM ROOMS SHALL BE SMOKE RATED AND COMPLY WITH
THE LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531.
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
90A-401
C8
TELECOM
ROOM
C128
ACTUAL: 118 SF
TELECOM
ROOM
B106A
ACTUAL: 895 SF
TELECOM
ROOM
A129
ACTUAL: 165 SF
PROG: 170 SF
90A-401
C6
90A-401
F3
90A-401
C5
90A-401
C3
90A-401
F5
90A-401
F1
90A-401
C1
UPS
ROOM
C-C
269 SF
B
B
B
B
B
B
B
A4
B
TELECOM
ROOM
A129
165 SF
A
12'-5 7/8"
(E X
T 'G
V I F
'-7
/8
A
WAITING
A127
128 SF
TYP.
1' -0
7'-0"
5'-9"
IT CLOSET
A129
ACTUAL: 50 SF
WAITING
A127
ACTUAL: 249 SF
TELECOM
ROOM
A129
ACTUAL: 165 SF
PROG: 170 SF
TELECOM
ROOM
B106A
ACTUAL: 895 SF
B106B
B106A
B
B A
B
BB
A4
TELECOM
ROOM
C128
ACTUAL: 118 SF
C
TELECOM
ROOM
C128
ACTUAL: 118 SF
WAITING
A127
249 SF
IT CLOSET
A129
50 SF
COMPENSATION
PENSION
C128
126 SF
COMPENSATION
PENSION
C128
126 SF
GENERATOR
ROOM
C-B
ACTUAL: 326 SF
MECHANICAL
STORAGE
C-A
ACTUAL: 1054 SF
UPS
ROOM
C-C
ACTUAL: 269 SF
GENERATOR
ROOM
C-B
ACTUAL: 326 SF
MECHANICAL
STORAGE
C-A
ACTUAL: 1054 SF
UPS
ROOM
C-C
ACTUAL: 269 SF
TELECOM
ROOM
B106A
895 SF
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
B
IM
/5
A
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e a t L e a v e n w o rt h
K S
V A
M C
/5
A
-2
-7
.L E
H R
M .B
.8
.9 .9
.A
R C
H .r v t
/1
/2
:2
:2
P
M
90A-401
ARCHITECTURAL ENLARGED VIEWS - FIRST
LEVEL
589A6-21-700
B88/89/90/91
01/19/2022 M. Perkins K. McDermott
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
4101 4TH ST TRAFFICWAY, LEAVENWORTH, KS 66048
1/32" = 1'-0" F6
FIRST LEVEL REFERENCE PLAN
1/4" = 1'-0" C8
ARCHITECTURAL ENLARGED FLOOR PLAN -
FIRST LEVEL - ROOM A129
1 REMOVE EXISTING DOOR AND FRAME.
2 REMOVE EXISTING DOOR AND FRAME. INFILL OPENING TO MATCH
ADJACENT CONSTRUCTION AND FINISH FOR CONTINUOUS
SURFACE.
3 REMOVE EXISTING WALL AND FRAMING. REMOVE/ RELOCATE
EXISTING WALL-MOUNTED EQUIPMENT. REFER TO ELECTRICAL
AND TELECOMMUNICATION PLANS.
4 REMOVE EXISTING FLOORING AND WALL BASE.
6 EXISTING WALLS TO BECOME SMOKE RATED. PATCH AND SEAL
ALL PENETRATIONS AS NECESSARY.
7 REMOVE EXISTING ACOUSTICAL CEILING AND LIGHTS. MODIFY
AND/OR PROVIDE ADDITIONAL SUPPORTS AS REQUIRED FOR
EXISTING CEILING ITEMS TO REMAIN.
8 RELOCATE LIGHT FIXTURE FOR NEW WALL LOCATION
9 TELECOM ROOM TO BE OPEN TO DECK ABOVE.
10 VENDING MACHINE
11 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE
2A:10B:C FIRE EXTINGUISHER LOCATED NO GREATER THAN 75
FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE
THE NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A
NEW FEC FOR EACH TR IN THE SCOPE OF WORK. SEE
SPECIFICATION 10 44 13.
12 PROVIDE TEMPORARY AIRTIGHT BARRIER AROUND WORK AREA
DURING ANY ACTIVITIES WHICH PRODUCE DUST - TYPICAL
13 TEMPORARY WALLS FOR ICRA ENCLOSURE
14 TEMPORARY DOOR AND STICKY MATS FOR ICRA ENCLOSURE
1/4" = 1'-0" C6
ARCHITECTURAL ENLARGED FLOOR PLAN -
FIRST LEVEL - ROOM A129 - DEMO
1/4" = 1'-0" B8
ARCHITECTURAL REFLECTED CEILING PLAN -
FIRST LEVEL - ROOM A127 - NEW
1/4" = 1'-0"
B6
ARCHITECTURAL REFLECTED CEILING PLAN -
FIRST LEVEL - ROOM A127 - DEMO
1/4" = 1'-0" F3
ARCHITECTURAL ENLARGED FLOOR PLAN - FIRST LEVEL - ROOM B106A - NEW
1/4" = 1'-0" C5
ARCHITECTURAL ENLARGED FLOOR PLAN -
FIRST LEVEL - ROOM C128 - NEW
1/4" = 1'-0"
C3
ARCHITECTURAL ENLARGED FLOOR PLAN -
FIRST LEVEL - ROOM C128 - DEMO
1/4" = 1'-0" B5
ARCHITECTURAL REFLECTED CEILING PLAN -
FIRST LEVEL - ROOM C128 - NEW
1/4" = 1'-0"
B3
ARCHITECTURAL REFLECTED CEILING PLAN -
FIRST LEVEL - ROOM C128 - DEMO
Revisions: Date:
ASI 1 04/13/22
1/4" = 1'-0" F1
ARCHITECTURAL ENLARGED FLOOR PLAN -
FIRST LEVEL - ROOM C-C - NEW
1/4" = 1'-0" C1
ARCHITECTURAL ENLARGED FLOOR PLAN -
FIRST LEVEL - ROOM C-C - DEMO
1/4" = 1'-0" F5
ARCHITECTURAL ENLARGED FLOOR PLAN - FIRST LEVEL - ROOM B106A - DEMO
04/18/22
/18
O S
DN
DN
UP
DN
DN
DN
UPUP
UP UP
90A-402
C6
TELECOM
ROOM
C228
ACTUAL: 136 SF
TELECOM
ROOM
A214
ACTUAL: 129 SF
TELECOM
ROOM
B216
ACTUAL: 87 SF
90A-402
C4
90A-402
F4
90A-402
C8
90A-402
C2
90A-402
F2
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW TELECOM ROOMS SHALL BE SMOKE RATED AND COMPLY WITH
THE LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531.
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
TELECOM
ROOM
B216
87 SF
TELECOM
ROOM
A214
ACTUAL: 129 SF
B
B
B
A 4 B
A
TELECOM
ROOM
C228
ACTUAL: 136 SF
B
B
B
B
B A
C
A
B
B
B
B
TELECOM
ROOM
B216
87 SF
TELECOM
ROOM
C228
ACTUAL: 136 SF
7 7
TELECOM
ROOM
B216
ACTUAL: 87 SF
TELECOM
ROOM
A214
ACTUAL: 129 SF
IT CLOSET
A214
ACTUAL: 135 SF
EQUIPMENT
STORAGE
C228
ACTUAL: 144 SF
IT CLOSET
A214
135 SF
EQUIPMENT
STORAGE
C228
144 SF
TELECOM
ROOM
B216
89 SF
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
B
IM
/5
A
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e a t L e a v e n w o rt h
K S
V A
M C
/5
A
-2
-7
.L E
H R
M .B
.8
.9 .9
.A
R C
H .r v t
/1
/2
:2
:3
P
M
90A-402
ARCHITECTURAL ENLARGED VIEWS - SECOND
LEVEL
589A6-21-700
B88/89/90/91
01/19/2022 M. Perkins K. McDermott
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
4101 4TH ST TRAFFICWAY, LEAVENWORTH, KS 66048
1/32" = 1'-0" F6
SECOND LEVEL REFERENCE PLAN
1 REMOVE EXISTING DOOR AND FRAME.
2 EXISTING WALLS TO BECOME SMOKE RATED. PATCH AND SEAL
ALL PENETRATIONS AS NECESSARY.
3 REMOVE EXISTING FLOORING AND WALL BASE.
4 NEW FURRING WALL AT EXTERIOR WALL TO ENCLOSE WINDOW.
MAINTAIN 1/2" GAP BETWEEN EXISTING WALL INTERIOR FACE AND
NEW STUDS. MODIFY/ REMOVE INTERIOR WINDOW TRIM AS
REQUIRED.
5 REMOVE EXISTING ACOUSTICAL CEILING AND LIGHTS. MODIFY
AND/OR PROVIDE ADDITIONAL SUPPORTS AS REQUIRED FOR
EXISTING CEILING ITEMS TO REMAIN.
6 REMOVE EXISTING LIGHT FIXTURE.
7 TELECOM ROOM TO BE OPEN TO DECK ABOVE.
8 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE
2A:10B:C FIRE EXTINGUISHER LOCATED NO GREATER THAN 75
FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE
THE NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A
NEW FEC FOR EACH TR IN THE SCOPE OF WORK. SEE
SPECIFICATION 10 44 13.
9 PROVIDE TEMPORARY AIRTIGHT BARRIER AROUND WORK AREA
DURING ANY ACTIVITIES WHICH PRODUCE DUST - TYPICAL
1/4" = 1'-0" C6
ARCHITECTURAL ENLARGED FLOOR PLAN -
SECOND LEVEL - ROOM B216 - DEMO
1/4" = 1'-0" F4
ARCHITECTURAL ENLARGED FLOOR PLAN -
SECOND LEVEL - ROOM A214 - NEW
1/4" = 1'-0" C4
ARCHITECTURAL ENLARGED FLOOR PLAN -
SECOND LEVEL - ROOM C228 - NEW
1/4" = 1'-0"
C8
ARCHITECTURAL ENLARGED FLOOR PLAN -
SECOND LEVEL - ROOM B216 - NEW
1/4" = 1'-0" F2
ARCHITECTURAL ENLARGED FLOOR PLAN -
SECOND LEVEL - ROOM A214 - DEMO
1/4" = 1'-0" C2
ARCHITECTURAL ENLARGED FLOOR PLAN -
SECOND LEVEL - ROOM C228 - DEMO
1/4" = 1'-0" B4
ARCHITECTURAL REFLECTED CEILING PLAN -
SECOND LEVEL - ROOM C228 - NEW
1/4" = 1'-0"
B8
ARCHITECTURAL REFLECTED CEILING PLAN -
SECOND LEVEL - ROOM B216 - NEW
1/4" = 1'-0" E4
ARCHITECTURAL REFLECTED CEILING PLAN -
SECOND LEVEL - ROOM A214 - NEW
1/4" = 1'-0"
E2
ARCHITECTURAL REFLECTED CEILING PLAN -
SECOND LEVEL - ROOM A214 - DEMO
1/4" = 1'-0" B2
ARCHITECTURAL REFLECTED CEILING PLAN -
SECOND LEVEL - ROOM C228 - DEMO
1/4" = 1'-0"
B6
ARCHITECTURAL REFLECTED CEILING PLAN -
SECOND LEVEL - ROOM B216 - DEMO
Revisions: Date:
ASI 1 04/13/22
04/18/22
/18
UPDNUP
DNUPDNUP
UPDN DNUP
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW TELECOM ROOMS SHALL BE SMOKE RATED AND COMPLY WITH
THE LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531.
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
TELECOM
ROOM
B341B341
90A-403
C8
TELECOM
ROOM
C346
ACTUAL: 121 SF
TELECOM
ROOM
A329
ACTUAL: 128 SF
90A-403
C4
90A-403
F4
90A-403
F2
90A-403
C2
90A-403
C6
TELECOM
ROOM
B341
ACTUAL: 108 SF
PROG: 170 SF
B
B
B
B
B
A
A4
B
(EXT'G VIF)
9'-5 3/4"
(E X
T 'G
V
IF
'-2
/4
TELECOM
ROOM
A329
ACTUAL: 128 SF
B
A 4 B
B
B
B
A
(EXT'G VIF)
9'-2 5/8"
(E X
T 'G
V
IF
'-1
3/ 4"
TELECOM
ROOM
C346
ACTUAL: 121 SF
B
B B
B
A
(EXT'G VIF)
9'-2 1/2"
(E X
T 'G
V I F
'-4
/8
C
TELECOM
ROOM
B341
ACTUAL: 108 SF
PROG: 170 SF
TELECOM
ROOM
A329
ACTUAL: 128 SF
TELECOM
ROOM
C346
ACTUAL: 121 SF
STORAGE
P&LM
A331
ACTUAL: 146 SF
IT CLOSET
A330
ACTUAL: 51 SF
HOME
OXYGEN
OFFICE
A329
ACTUAL: 136 SF
DATA
C346
ACTUAL: 131 SF
HOME
OXYGEN
OFFICE
A329
136 SF
IT CLOSET
A330
51 SF
STORAGE
P&LM
A331
146 SF
DATA
C346
131 SF
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
B
IM
/5
A
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e a t L e a v e n w o rt h
K S
V A
M C
/5
A
-2
-7
.L E
H R
M .B
.8
.9 .9
.A
R C
H .r v t
/1
/2
:2
:4
P
M
90A-403
ARCHITECTURAL ENLARGED VIEWS - THIRD
LEVEL
589A6-21-700
B88/89/90/91
01/19/2022 M. Perkins K. McDermott
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
4101 4TH ST TRAFFICWAY, LEAVENWORTH, KS 66048
1/32" = 1'-0" F6
THIRD LEVEL REFERENCE PLAN - B90
1/4" = 1'-0" C8
ARCHITECTURAL ENLARGED FLOOR PLAN -
THIRD LEVEL - ROOM B341 - NEW
1 REMOVE EXISTING WALL AND FRAMING. REMOVE/ RELOCATE
EXISTING WALL-MOUNTED EQUIPMENT. REFER TO ELECTRICAL
AND TELECOMMUNICATION PLANS.
2 REMOVE EXISTING PLUMBING FIXTURE. CUT AND CAP EXISTING
PIPING BACK TO MAIN. COORDINATE ALL SHUTDOWNS WITH THE
FACILITY.
3 REMOVE EXISTING FLOORING AND WALL BASE.
4 EXISTING DOOR TO BE SMOKE-RATED. SEE DOOR SCHEDULE AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
5 EXISTING WALLS TO BECOME SMOKE RATED. PATCH AND SEAL
ALL PENETRATIONS AS NECESSARY.
6 REMOVE EXISTING ACOUSTICAL CEILING AND LIGHTS. MODIFY
AND/OR PROVIDE ADDITIONAL SUPPORTS AS REQUIRED FOR
EXISTING CEILING ITEMS TO REMAIN.
7 REMOVE EXISTING GYPSUM CEILING AND LIGHTS. MODIFY
AND/OR PROVIDE ADDITIONAL SUPPORTS AS REQUIRED FOR
EXISTING CEILING ITEMS TO REMAIN.
8 TELECOM ROOM TO BE OPEN TO DECK ABOVE.
9 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE
2A:10B:C FIRE EXTINGUISHER LOCATED NO GREATER THAN 75
FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE
THE NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A
NEW FEC FOR EACH TR IN THE SCOPE OF WORK. SEE
SPECIFICATION 10 44 13.
10 REMOVE EXISTING DOOR AND FRAME.
11 PROVIDE TEMPORARY AIRTIGHT BARRIER AROUND WORK AREA
DURING ANY ACTIVITIES WHICH PRODUCE DUST - TYPICAL
12 TEMPORARY WALLS FOR ICRA ENCLOSURE
1/4" = 1'-0" F4
ARCHITECTURAL ENLARGED FLOOR PLAN -
THIRD LEVEL - ROOM A329 - NEW
1/4" = 1'-0" C4
ARCHITECTURAL ENLARGED FLOOR PLAN -
THIRD LEVEL - ROOM C346 - NEW
1/4" = 1'-0" F2
ARCHITECTURAL ENLARGED FLOOR PLAN -
THIRD LEVEL - ROOM A329 - DEMO
1/4" = 1'-0" C2
ARCHITECTURAL ENLARGED FLOOR PLAN -
THIRD LEVEL - ROOM C346 - DEMO
1/4" = 1'-0"
C6
ARCHITECTURAL ENLARGED FLOOR PLAN -
THIRD LEVEL - ROOM B341 - DEMO
1/4" = 1'-0" B8
ARCHITECTURAL REFLECTED CEILING PLAN -
THIRD LEVEL - ROOM B341 - NEW
1/4" = 1'-0" E4
ARCHITECTURAL REFLECTED CEILING PLAN -
THIRD LEVEL - ROOM A329 - NEW
1/4" = 1'-0" B4
ARCHITECTURAL ENLARGED FLOOR PLAN -
THIRD LEVEL - ROOM C346 - NEW
1/4" = 1'-0" B6
ARCHITECTURAL REFLECTED CEILING PLAN -
THIRD LEVEL - ROOM B341 - DEMO
1/4" = 1'-0" E2
ARCHITECTURAL REFLECTED CEILING PLAN -
THIRD LEVEL - ROOM A329 - DEMO
1/4" = 1'-0" B2
ARCHITECTURAL REFLECTED CEILING PLAN -
THIRD LEVEL - ROOM C346 - DEMO
Revisions: Date:
ASI 1 04/13/22
1 1
04/18/22
/18
UPUPUPUP
UPDN DNUP
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW TELECOM ROOMS SHALL BE SMOKE RATED AND COMPLY WITH
THE LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531.
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
TELECOM
ROOM
A419
126 SF 90A-404
F4
TELECOM
ROOM
C436
ACTUAL: 112 SF
90A-404
C8
90A-404
C4
90A-404
F2
90A-404
C2
TELECOM
ROOM
B417A
ACTUAL: 103 SF
TELECOM
ROOM
A419
ACTUAL: 126 SF
PROG: 170 SF
B
B A
B
A
(EXT'G VIF)
9'-0 3/4"
(E X
T 'G
V I F
'-1
B
B
B
B
B
B A
TELECOM
ROOM
B417A
ACTUAL: 103 SF
11'-3"
9' -5
4'-0"
3' -0
TELECOM
ROOM
C436
ACTUAL: 112 SF
B
B
B
A 4 B
(EXT'G VIF)
9'-2"
(E X
T 'G
V
IF
'-5
C
CLR MIN
4'-0"
'-1
0"
9' -6
11'-4"
TELECOM
ROOM
C436
ACTUAL: 112 SF
9 9
TELECOM
ROOM
B417A
ACTUAL: 103 SF
TELECOM
ROOM
A419
ACTUAL: 126 SF
PROG: 170 SF
A419
TELECOM
ROOM
A417A
STORAGE
BLOOD
DRAW
WAITING
B417
ACTUAL: 544 SF
C436
SURGERY
OFFICE
BLOOD
DRAW
WAITING
B417
544 SF
SURGERY
OFFICE
C436
120 SF
TELECOM
ROOM
A419
76 SF
STORAGE
A417A
54 SF
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
B
IM
/5
A
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e a t L e a v e n w o rt h
K S
V A
M C
/5
A
-2
-7
.L E
H R
M .B
.8
.9 .9
.A
R C
H .r v t
/1
/2
:2
:5
P
M
90A-404
ARCHITECTURAL ENLARGED VIEWS - FOURTH
LEVEL
589A6-21-700
B88/89/90/91
01/19/2022 M. Perkins K. McDermott
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
4101 4TH ST TRAFFICWAY, LEAVENWORTH, KS 66048
1 REMOVE EXISTING WALL AND FRAMING. REMOVE/ RELOCATE
EXISTING WALL-MOUNTED EQUIPMENT. REFER TO ELECTRICAL
AND TELECOMMUNICATION PLANS.
2 REMOVE EXISTING DOOR AND FRAME. INFILL OPENING TO MATCH
ADJACENT CONSTRUCTION AND FINISH FOR CONTINUOUS
SURFACE.
4 REMOVE EXISTING FLOORING AND WALL BASE.
6 EXISTING WALLS TO BECOME SMOKE RATED. PATCH AND SEAL
ALL PENETRATIONS AS NECESSARY.
7 NEW FURRING WALL AT EXTERIOR WALL TO ENCLOSE WINDOW.
MAINTAIN 1/2" GAP BETWEEN EXISTING WALL INTERIOR FACE AND
NEW STUDS. MODIFY/ REMOVE INTERIOR WINDOW TRIM AS
REQUIRED.
8 REMOVE EXISTING ACOUSTICAL CEILING AND LIGHTS. MODIFY
AND/OR PROVIDE ADDITIONAL SUPPORTS AS REQUIRED FOR
EXISTING CEILING ITEMS TO REMAIN.
9 TELECOM ROOM TO BE OPEN TO DECK ABOVE.
10 REMOVE EXISTING DOOR AND FRAME.
11 NEW SMOKE RATED DOOR. SEE DOOR SCHEDULE AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE
DOOR AND FRAME WITH ACCESS CONTROL HARDWARE.
12 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE
2A:10B:C FIRE EXTINGUISHER LOCATED NO GREATER THAN 75
FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE
THE NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A
NEW FEC FOR EACH TR IN THE SCOPE OF WORK. SEE
SPECIFICATION 10 44 13.
13 PROVIDE TEMPORARY AIRTIGHT BARRIER AROUND WORK AREA
DURING ANY ACTIVITIES WHICH PRODUCE DUST - TYPICAL
14 TEMPORARY WALLS FOR ICRA ENCLOSURE
15 TEMPORARY DOOR AND STICKY MATS FOR ICRA ENCLOSURE
1/32" = 1'-0" F6
FOURTH LEVEL REFERENCE PLAN - B90
1/4" = 1'-0"
F4
ARCHITECTURAL ENLARGED FLOOR PLAN -
FOURTH LEVEL - ROOM A419 - NEW
1/4" = 1'-0" C8
ARCHITECTURAL ENLARGED FLOOR PLAN -
FOURTH LEVEL - ROOM B411 - NEW
1/4" = 1'-0"
C4
ARCHITECTURAL ENLARGED FLOOR PLAN -
FOURTH LEVEL - ROOM C436 - NEW
1/4" = 1'-0" F2
ARCHITECTURAL ENLARGED FLOOR PLAN -
FOURTH LEVEL - ROOM A419 - DEMO
1/4" = 1'-0" C6
ARCHITECTURAL ENLARGED FLOOR PLAN -
FOURTH LEVEL - ROOM B411 - DEMO
1/4" = 1'-0"
C2
ARCHITECTURAL ENLARGED FLOOR PLAN -
FOURTH LEVEL - ROOM C436 - DEMO
1/4" = 1'-0" B4
ARCHITECTURAL REFLECTED CEILING PLAN -
FOURTH LEVEL - ROOM C436 - NEW
1/4" = 1'-0"
B8
ARCHITECTURAL REFLECTED CEILING PLAN -
FOURTH LEVEL - ROOM B411A - NEW
1/4" = 1'-0" E4
ARCHITECTURAL REFLECTED CEILING PLAN -
FOURTH LEVEL - ROOM A419 - NEW
1/4" = 1'-0" B2
ARCHITECTURAL REFLECTED CEILING PLAN -
FOURTH LEVEL - ROOM C436 - DEMO
1/4" = 1'-0" E2
ARCHITECTURAL REFLECTED CEILING PLAN -
FOURTH LEVEL - ROOM A419 - DEMO
1/4" = 1'-0" B6
ARCHITECTURAL REFLECTED CEILING PLAN -
FOURTH LEVEL - ROOM B411A - DEMO
Revisions: Date:
ASI 1 04/13/22
04/18/22
/18
DNDN
DN
DN
UP
UP
DNDN
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW TELECOM ROOMS SHALL BE SMOKE RATED AND COMPLY WITH
THE LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531.
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
TELECOM
ROOM
C511C511
90A-405
C4
TELECOM
ROOM
A521
ACTUAL: 127 SF
90A-405
F4
90A-405
F2
90A-405
C2
90A-405
C6
BIO-MED
SERVER
ROOM
B504BB504B
90A-405
C8
TELECOM
ROOM
C511
ACTUAL: 139 SF
PROG: 170 SF
B
B A
B
B
B
(EXT'G VIF)
10'-4 3/4"
(E X
T 'G
V
IF
'-8
/8
C
A4
TELECOM
ROOM
A521
ACTUAL: 127 SF
A4
A
A
B
B
B
B
TELECOM
ROOM
A521
ACTUAL: 127 SF
TELECOM
ROOM
C511
ACTUAL: 139 SF
PROG: 170 SF
PHARMACIST
C511C511
TELE
A521BA521B
CLINIC
CHECK-IN
A521A521
BIO-MED
SERVER
ROOM
B504B
ACTUAL: 217 SF
B
B
B
B
E X
T G
V
IF
'-7
/8
EXTG VIF
16'-4 5/8"
A4
12B B
BIO-MED
SERVER
ROOM
B504B
ACTUAL: 217 SF
BIO-MED
SERVER
ROOM
B504B
217 SF
BIO-MED
SERVER
ROOM
B504B
ACTUAL: 217 SF
TELE
A521B
13 SF
CLINIC
CHECK-IN
A521
380 SF
PHARMACIST
C511
129 SF
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
B
IM
/5
A
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e a t L e a v e n w o rt h
K S
V A
M C
/5
A
-2
-7
.L E
H R
M .B
.8
.9 .9
.A
R C
H .r v t
/1
/2
:2
:5
P
M
90A-405
ARCHITECTURAL ENLARGED VIEWS - FIFTH
LEVEL
589A6-21-700
B88/89/90/91
01/19/2022 M. Perkins K. McDermott
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
4101 4TH ST TRAFFICWAY, LEAVENWORTH, KS 66048
1 REMOVE EXISTING WALL AND FRAMING. REMOVE/ RELOCATE
EXISTING WALL-MOUNTED EQUIPMENT. REFER TO ELECTRICAL
AND TELECOMMUNICATION PLANS.
2 REMOVE EXISTING DOOR AND FRAME.
3 REMOVE EXISTING PLUMBING FIXTURE. CUT AND CAP EXISTING
PIPING BACK TO MAIN. COORDINATE ALL SHUTDOWNS WITH THE
FACILITY.
4 REMOVE EXISTING FLOORING AND WALL BASE.
5 NEW SMOKE RATED DOOR. SEE DOOR SCHEDULE AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE
DOOR AND FRAME WITH ACCESS CONTROL HARDWARE.
7 EXISTING WALLS TO BECOME SMOKE RATED. PATCH AND SEAL
ALL PENETRATIONS AS NECESSARY.
8 NEW FURRING WALL AT EXTERIOR WALL TO ENCLOSE WINDOW.
MAINTAIN 1/2" GAP BETWEEN EXISTING WALL INTERIOR FACE AND
NEW STUDS. MODIFY/ REMOVE INTERIOR WINDOW TRIM AS
REQUIRED.
9 REMOVE EXISTING ACOUSTICAL CEILING AND LIGHTS. MODIFY
AND/OR PROVIDE ADDITIONAL SUPPORTS AS REQUIRED FOR
EXISTING CEILING ITEMS TO REMAIN.
10 REMOVE EXISTING GYPSUM CEILING AND LIGHTS. MODIFY AND/OR
PROVIDE ADDITIONAL SUPPORTS AS REQUIRED FOR EXISTING
CEILING ITEMS TO REMAIN.
11 TELECOM ROOM TO BE OPEN TO DECK ABOVE.
12 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE
2A:10B:C FIRE EXTINGUISHER LOCATED NO GREATER THAN 75
FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE
THE NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A
NEW FEC FOR EACH TR IN THE SCOPE OF WORK. SEE
SPECIFICATION 10 44 13.
13 PROVIDE TEMPORARY AIRTIGHT BARRIER AROUND WORK AREA
DURING ANY ACTIVITIES WHICH PRODUCE DUST - TYPICAL
1/32" = 1'-0" F6
FIFTH LEVEL REFERENCE PLAN - B90
1/4" = 1'-0" C4
ARCHITECTURAL ENLARGED FLOOR PLAN -
FIFTH LEVEL - ROOM C511 - NEW
1/4" = 1'-0" F4
ARCHITECTURAL ENLARGED FLOOR PLAN -
FIFTH LEVEL - ROOM A521 - NEW
1/4" = 1'-0"
F2
ARCHITECTURAL ENLARGED FLOOR PLAN -
FIFTH LEVEL - ROOM A521 - DEMO
1/4" = 1'-0" C2
ARCHITECTURAL ENLARGED FLOOR PLAN -
FIFTH LEVEL - ROOM C511 - DEMO
1/4" = 1'-0" E4
ARCHITECTURAL REFLECTED CEILING PLAN -
FIFTH LEVEL - ROOM A521 - NEW
1/4" = 1'-0" B4
ARCHITECTURAL REFLECTED CEILING PLAN -
FIFTH LEVEL - ROOM C511 - NEW
1/4" = 1'-0" E2
ARCHITECTURAL REFLECTED CEILING PLAN -
FIFTH LEVEL - ROOM A521 - DEMO
1/4" = 1'-0" B2
ARCHITECTURAL REFLECTED CEILING PLAN -
FIFTH LEVEL - ROOM C511 - DEMO
1/4" = 1'-0" C8
ARCHITECTURAL ENLARGED FLOOR PLAN -
FIFTH LEVEL - ROOM B504B - NEW
1/4" = 1'-0"
C6
ARCHITECTURAL ENLARGED FLOOR PLAN -
FIFTH LEVEL - ROOM B504B - DEMO
1/4" = 1'-0" B6
ARCHITECTURAL REFLECTED CEILING PLAN -
FIFTH LEVEL - ROOM B504B - DEMO
1/4" = 1'-0"
B8
ARCHITECTURAL REFLECTED CEILING PLAN -
FIFTH LEVEL - ROOM B504B - NEW
Revisions: Date:
ASI 1 04/13/22
04/18/22
/18
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW TELECOM ROOMS SHALL BE SMOKE RATED AND COMPLY WITH
THE LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531.
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
TELECOM
ROOM
A621A
ACTUAL: 110 SF
TELECOM
ROOM
C622
ACTUAL: 137 SF
PROG: 170 SF
TELECOM
ROOM
B623
ACTUAL: 98 SF
90A-406
C4
90A-406
C8
90A-406
F4
90A-406
C6
90A-406
F2
90A-406
C2
ATTIC SPACE
B
B A
B
B
A621A
TELECOM
ROOM
A621A
ACTUAL: 110 SF
TYP.
7'-9 1/4"
(E X
T 'G
V
IF
'-2
/8
A4
TELECOM
ROOM
B623
ACTUAL: 98 SF
B
B
B
B
B
(EXT'G VIF)
11'-1 1/4"
(E X
T 'G
V
IF
8'
-1 1"
TELECOM
ROOM
C622
ACTUAL: 137 SF
PROG: 170 SF
B
B A
B
B
C
(EXT'G VIF)
11'-10 3/8"
(E X
T 'G
V
IF
'-1
1/ 2"
CHASE
C622PC622P
B
B
B
TELECOM
ROOM
A621AA621A
HUD-VASH
A621A621
TELECOM
ROOM
B623
ACTUAL: 98 SF
TELECOM
ROOM
C622
ACTUAL: 137 SF
PROG: 170 SF
TELECOM
ROOM
A621A
ACTUAL: 110 SF
IT CLOSET
B600AB600A
MECHANICAL
ATTIC
B600B600
NURSE
MANAGER
C622C622
CHASE
C622PC622P
NURSE
MANAGER
C622
145 SF
IT
A621A
50 SF
HUD-VASH
A621
181 SF
IT CLOSET
B600A
16 SF
MECHANICAL
ATTIC
B600
202 SF
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
B
IM
/5
A
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e a t L e a v e n w o rt h
K S
V A
M C
/5
A
-2
-7
.L E
H R
M .B
.8
.9 .9
.A
R C
H .r v t
/1
/2
:2
:0
P
M
90A-406
ARCHTECTURAL ENLARGED VIEWS - SIXTH
LEVEL
589A6-21-700
B88/89/90/91
01/19/2022 M. Perkins K. McDermott
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
4101 4TH ST TRAFFICWAY, LEAVENWORTH, KS 66048
1/32" = 1'-0" F6
SIXTH LEVEL REFERENCE PLAN
1 REMOVE EXISTING WALL AND FRAMING. REMOVE/ RELOCATE
EXISTING WALL-MOUNTED EQUIPMENT. REFER TO ELECTRICAL
AND TELECOMMUNICATION PLANS.
2 REMOVE EXISTING DOOR AND FRAME.
3 REMOVE EXISTING FLOORING AND WALL BASE.
4 EXISTING DOOR TO BE SMOKE-RATED. SEE DOOR SCHEDULE
AND SPECIFICATIONS FOR ADDITIONAL INFORMATION.
5 NEW SMOKE RATED DOOR. SEE DOOR SCHEDULE AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE
DOOR AND FRAME WITH ACCESS CONTROL HARDWARE.
6 EXISTING WALLS TO BECOME SMOKE RATED. PATCH AND SEAL
ALL PENETRATIONS AS NECESSARY.
7 NEW FURRING WALL AT EXTERIOR WALL TO ENCLOSE WINDOW.
MAINTAIN 1/2" GAP BETWEEN EXISTING WALL INTERIOR FACE
AND NEW STUDS. MODIFY/ REMOVE INTERIOR WINDOW TRIM AS
REQUIRED.
8 REMOVE EXISTING ACOUSTICAL CEILING AND LIGHTS. MODIFY
AND/OR PROVIDE ADDITIONAL SUPPORTS AS REQUIRED FOR
EXISTING CEILING ITEMS TO REMAIN.
9 TELECOM ROOM TO BE OPEN TO DECK ABOVE.
10 MODIFY EXISTING CEILING AS NECESSARY FOR NEW WALL.
11 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE
2A:10B:C FIRE EXTINGUISHER LOCATED NO GREATER THAN 75
FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE
THE NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A
NEW FEC FOR EACH TR IN THE SCOPE OF WORK. SEE
SPECIFICATION 10 44 13.
12 PROVIDE TEMPORARY AIRTIGHT BARRIER AROUND WORK AREA
DURING ANY ACTIVITIES WHICH PRODUCE DUST - TYPICAL
13 TEMPORARY WALLS FOR ICRA ENCLOSURE
14 TEMPORARY DOOR AND STICKY MATS FOR ICRA ENCLOSURE
1/4" = 1'-0" F4
ARCHITECTURAL ENLARGED FLOOR PLAN -
SIXTH LEVEL - ROOM A621A - NEW
1/4" = 1'-0" C8
ARCHITECTURAL ENLARGED FLOOR PLAN -
SIXTH LEVEL - ROOM B623 - NEW
1/4" = 1'-0"
C4
ARCHITECTURAL ENLARGED FLOOR PLAN -
SIXTH LEVEL - ROOM C622 - NEW
1/4" = 1'-0" F2
ARCHITECTURAL ENLARGED FLOOR PLAN -
SIXTH LEVEL - ROOM A621A - DEMO
1/4" = 1'-0" C6
ARCHITECTURAL ENLARGED FLOOR PLAN -
SIXTH LEVEL - ROOM B623 - DEMO
1/4" = 1'-0" C2
ARCHITECTURAL ENLARGED FLOOR PLAN -
SIXTH LEVEL - ROOM C622 - DEMO
1/4" = 1'-0" B8
ARCHITECTURAL REFLECTED CEILING PLAN -
SIXTH LEVEL - ROOM B623 - NEW
1/4" = 1'-0"
B4
ARCHITECTURAL REFLECTED CEILING PLAN -
SIXTH LEVEL - ROOM C622 - NEW
1/4" = 1'-0" E4
ARCHITECTURAL REFLECTED CEILING PLAN -
SIXTH LEVEL - ROOM A621A - NEW
1/4" = 1'-0"
E2
ARCHITECTURAL REFLECTED CEILING PLAN -
SIXTH LEVEL - ROOM A621A - DEMO
1/4" = 1'-0" B6
ARCHITECTURAL REFLECTED CEILING PLAN -
SIXTH LEVEL - ROOM B623 - DEMO
1/4" = 1'-0"
B2
ARCHITECTURAL REFLECTED CEILING PLAN -
SIXTH LEVEL - ROOM C622 - DEMO
Revisions: Date:
ASI 1 04/13/22
04/18/22
/18
ENGINEERING
A150E
LEADS TO STEAM TUNNELS
B127
CLEAN ROOM
B129C
BIOMED ENGINEERING
B129
ELECTRICAL PANELS
B131
GENERATOR
B131A
HOUSEKEEPING
B135
LINEN STORAGE
B137
STORAGE
B139
HOUSEKEEPING
B130
RESTROOM
B128B
LOCKER ROOM
B128A
BREAK ROOM
B128
STERILE PROCESSING
B126
STERILE PROCESSING
B126A
STERILE PROCESSING
B124A
STERILE PROCESSING
B124
STERILE PROCESSING
B122
ARMORY
A150C
EVIDENCE ROOM
A150D
H.V.A.C.
B134A
LOADING DOCK
B134
STORAGE
B137A
STORAGE
B137B
OXYGEN STORAGE
B134E
OXYGEN STORAGE
B134D
BIOHAZARD/HKPG
B134C
MECHANICAL SPACE
B134B
FIRE PROTECTION
B141
CORRIDOR
B1-C4
CORRIDOR
B1-C5
CORRIDOR
B1-C6
HOUSEKEEPING
B126B
STAIR 3
B1-S3
STORAGE
B126C
VESTIBULE
B134F
ELEV#2
B1-E2
-E
G
-E
D P
G -1
E
D P
G
-E
D P
G -2
M A
IN
-A
T S
-2
GEN
89-1
SEC 1
SEC 2
TRANS-90-RX
90SWG/90-MB1
/8
S
W G
S
W G
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
KEYNOTES
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
STAMP
B89B89
B
IM
/5
A
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e a t L e a v e n w o rt h K
S V
A M
C /5
A
-2
-7
.L E
H R
M .B
.8 .9
.9
.M
E P
.r v t
/1
/2
:3
:0
P
M
89E-101
ELECTRICAL PLANS -…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .