589A6-21-700.LEHRM.ASI-001.B39.20220418.pdf
PDF 1 MB Posted
- Solicitation number
- 36C77622R0061
About this file
This solicitation is for a construction project to prepare a Veterans Affairs medical campus for Electronic Health Record Modernization upgrades. The scope of work includes replacing all telecommunications cabling in multiple buildings on the campus with CAT6A copper and OM4 and OS2 optical fiber. In addition to a one-for-one replacement, an additional 15% capacity must be provided. New computer room air conditioning systems, electrical panels, emergency generators, and a 600-ton water cooled chiller pump will also be installed. The selected contractor must terminate and label all cables according to specifications, install new patch panels and racks in the telecom rooms with 40% spare capacity, and provide welded cable support structures. Existing wireless access points and phone lines must be retained.
View the file
Other files
Show 40 more
Latest 50 of 67 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW TELECOM ROOM SHALL BE SMOKE RATED AND COMPLY WITH
THE LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
1/2" 1/2"
VARIES
SEE PLAN
WALL - SEE PLAN
FOR TYPE
SEALANT - EA. SIDE
& ALL AROUND,
TYP.
HOLLOW METAL
FRAME
/2
V
A R
IE
S
S E
E P
L A
N
/2
4" 2"
ADJACENT WALL
WHERE OCCURS
SEALANT - EA SIDE &
ALL AROUND, TYP.
HOLLOW METAL
FRAME
WALL - SEE PLAN
FOR TYPE
F4
TYPICAL FRAME
H E
IG
H
T
2" WIDTH 2"
F5
FRAME TYPE ELEVATIONS DOOR TYPE ELEVATIONS
F
FLUSH
F2
39A-401
D8
TELECOM
ROOM
B130
ACTUAL: 98 SF
PROG: 170 SF
B130
B
A4
B
A 4B
B
A
WAREHOUSE
B129B129
ACOUSTICAL OR RATED
SEALANT BOTH SIDES
FLOOR LINE
5/8" GWB BOTH SIDES
SOUND ATTENUATION
BATTS (SAB) PER
SCHEDULE.
CEILING LINE
STRUCTURAL DECK
METAL STUDS, SIZE
PER SCHEDULE
39A-512
D5
A/C GRADE, 3/4" FIRE-
TREATED PLYWOOD TO 8'-0"
ABOVE FINISHED FLOOR
39A-512
B5
AT FIRE RATED
PARTITIONS
AT SMOKE RATED
PARTITIONS
BOTTOM OF PLYWOOD TO
BE AT 12" AFF
ACOUSTICAL OR RATED
FLEXIBLE SEALANT
FLOOR LINE
ADD ONE LAYER OF 5/8" GWB,
ONE-SIDE WITH APPROVED UL
SETTING COMPOUND BETWEEN
LAYERS AND FASTENED TO
WALL AS REQUIRED, AT
EXISTING GWB WALL
ASSEMBLIES
STRUCTURAL DECK
EXISTING METAL STUDS AND
BATT INSULATION TO REMAIN
A/C GRADE, 3/4" FIRE-TREATED
PLYWOOD TO 8'-0" ABOVE FINISHED
FLOOR, ADHERED TO CONCRETE AT
EXISTING CONCRETE WALL
ASSEMBLIES
BOTTOM OF PLYWOOD
TO BE AT 12" AFF
UL DESIGN V497
1-HOUR PARTITION RATED FROM BOTH SIDES
EXISTING GWB OR
CONCRETE WALL
ASSEMBLY, WHERE OCCURS
SIDE OF
EXISTING
ROOM OR
CORRIDOR TO
REMAIN
39A-512
D5
39A-512
B5
IT CLOSET
130130
TELECOM
ROOM
B130B130
IT CLOSET
130130
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
STAMP
B
IM
/5
A -2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e a t L e a v e n w o rt h K
S V
A M
C /5
A
-2
-7
.L
E H
R M
.B
.A
R C
H .r v t
/1
/2
:1
:1
A
M
39A-401
ARCHITECTURAL ENLARGED VIEWS - FIRST
LEVEL
589A6-21-700
B39
01/19/2022 M. Perkins K. McDermott
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
4101 4th St Trafficway, Leavenworth, KS 66048
3" = 1'-0" C1
HOLLOW METAL HEAD DETAIL
3" = 1'-0"
C3
HOLLOW METAL JAMB DETAIL
1/4" = 1'-0" D1
WRAPPED FRAME TYPES ELEVATIONS
1 NEW SMOKE RATED DOOR. SEE DOOR SCHEDULE AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE
DOOR AND FRAME WITH ACCESS CONTROL HARDWARE.
2 ALL WALLS TO BE SMOKE-RATED. PATCH AND SEAL ALL
PENETRATIONS AS NECESSARY.
3 REMOVE EXISTING WALL AND FRAMING.
4 REMOVE EXISTING DOOR AND FRAME.
5 REMOVE EXISTING DOOR AND FRAME. INFILL OPENING TO
MATCH ADJACENT CONSTRUCTION AND FINISH FOR
CONTINUOUS SURFACE.
6 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE
2A:10B:C FIRE EXTINGUISHER LOCATED NO GREATER THAN 75
FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE
THE NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A
NEW FEC FOR EACH TR IN THE SCOPE OF WORK. SEE
SPECIFICATION 10 44 13.
7 TELECOM ROOM TO BE OPEN TO DECK ABOVE.
8 DEMOLISH EXISTING PLYWOOD CEILING.
1/32" = 1'-0" F6
FIRST LEVEL REFERENCE PLAN
1/4" = 1'-0" D8
ARCHITECTURAL FLOOR PLAN - FIRST LEVEL
- ROOM B130 - NEW
1/4" = 1'-0"
D6
ARCHITECTURAL FLOOR PLAN - FIRST LEVEL
- ROOM B130 - DEMO
DOOR AND FRAME SCHEDULE
IDENTIFICATION DIMENSIONS PANEL FRAME
FIRE RATING
HARDWARE
NOTESLEVEL ROOM NO. ROOM NAME DOOR NO. W1 H T TYPE MATERIAL FINISH GLAZING UNDERCUT TYPE MATERIAL FINISH GROUP ELECTRICAL
LEVEL 1 B130 TELECOM ROOM B130 3' - 0" 7' - 0" 1 3/4" F WD WD NONE 3/8" 1 HM PTD 45 MIN HW-SH-3F SEE ELEC 1, 2, 3
NOTE: FIRE RESISTANCE TEST FOR ONE HOUR RATED WALLS: UL
U465
(TYPE A) TYPICAL PARTITION
MARK STUD WIDTH PRTN WIDTH DESIGN STC
A4 4" 5 1/4" 35
NOTE: FIRE RESISTANCE TEST FOR TWO HOUR RATED WALLS: UL
V438, UL U411
(TYPE B) TYPICAL PARTITION
MARK STUD WIDTH PRTN WIDTH DESIGN STC
B 2 1/2" 3/4" 45
1/4" = 1'-0" C6
ARCHITECTURAL REFLECTED CEILING PLAN -
FIRST LEVEL - ROOM B130 - DEMO
1/4" = 1'-0"
C8
ARCHITECTURAL REFLECTED CEILING PLAN -
FIRST LEVEL - ROOM B130 - NEW
DOOR SCHEDULE NOTES:
1. TELECOM ROOM DOOR PANEL AND FRAME TO BE SMOKE RATED FOR TRANSITION,
INCLUDING CLOSER, SEALS, THRESHOLD, AND SWEEP.
2. PAINT DOOR TRIM TO MATCH EXISTING TRIM PAINT IN SPACE.
3. COORDINATE DOOR PANEL, FRAME, AND HARDWARE WITH ELECTRICAL HARDWARE
(ACCESS CONTROL, ELECTRICAL STRIKE, DOOR CONTACT SWITCH, ETC.) SEE ELECTRICAL
PLANS FOR ADDITIONAL INFORMATION.
Revisions: Date:
ASI 1 04/14/22
WAREHOUSE
SPACE
04/18/22
/18
/20
04/18/2022
| Sheets |
| 39A-401 - ARCHITECTURAL ENLARGED VIEWS - FIRST LEVEL |
File details come from the government source that posted it. Updated .