backflow information excel.xlsx

XLSX spreadsheet 13 KB Posted

Attached to
J042--Fire Alarm Service
Solicitation number
36C25626Q0430
Issued by

About this file

This file is a backflow prevention device identification inventory spreadsheet for the VA Medical Center (VAMC) Fayetteville. The document provides a comprehensive catalog of 51 existing fire protection and backflow prevention devices installed throughout the facility, organized by building number, floor, room location, and device identification. The inventory includes detailed specifications for each device, including the type of backflow preventer (Double Check or Reduced Pressure Principal), degree of hazard classification (Low or High Hazard), manufacturer, serial number, pipe size, and intended purpose such as fire protection, domestic water supply, HVAC cooling water feed, humidifier feed, and sterilization equipment.

The devices are distributed across 18 buildings within the VAMC campus, with the majority of inspections conducted in September 2016 and a few in February 2016. The inventory encompasses various manufacturers including Ames, Watts, Colt, Wilkins, Zurn-Wilkins, Febco, Combraco, and Apollo, with pipe sizes ranging from 3/4 inches to 8 inches. Low hazard devices are primarily Double Check units protecting fire suppression systems and meter bypass applications, while high hazard devices are predominantly Reduced Pressure Principal units safeguarding domestic water, HVAC systems, humidifiers, and other specialized equipment. This inventory appears to support the related federal contract opportunity for fire alarm inspection and services at the Veterans Health Administration facility.

View the file

Other files

File Type Posted
P09 SOW Fire Alarm Service 41326 final.docx DOCX document
36C25626Q0430 0006.pdf PDF
36C25626Q0430 0006.docx DOCX document
36C25626Q0430 0005.docx DOCX document
36C25626Q0430 0004.docx DOCX document
P09 SOW Fire Alarm Service Final 4426.docx DOCX document
564-18-135 Complete Dwgs Set.pdf PDF
Questions and answers for 36C25626Q0430 Post.docx DOCX document
36C25626Q0430 0003.docx DOCX document
P09_SOW Fire Alarm Service Revised.docx DOCX document
36C25626Q0430 0002.docx DOCX document
2025-09-15_Fayetteville-VAMC-Leroy-Pond_FireScan.pdf PDF
2025-09-08_Fayetteville-VAMC-Bldg-3_FireScan.pdf PDF
2025-09-15 Fayetteville-VAMC-Bldg-8 FireScan.pdf PDF
2025-09-08_Fayetteville-VAMC-Parking-Garage_FireScan.pdf PDF
2025-08-27_Fayetteville-VAMC-Bldg-37_FireScan.pdf PDF
2025-09-01_Fayetteville-VAMC-Bldg-7_FireScan.pdf PDF
2025-08-27_Fayetteville-VAMC-Bldg-11_FireScan.pdf PDF
36C25626Q0430 EXHIBIT C.docx DOCX document
2025-09-15_Fayetteville-VAMC-Bldg-1_FireScan.pdf PDF
2025-09-15_Fayetteville-VAMC-Bldg-27_FireScan.pdf PDF
2025-08-27 Fayetteville-VAMC-Red-Barn FireScan.pdf PDF
36C25626Q0430 EXHIBIT B.docx DOCX document
36C25626Q0430 EXHIBIT A.docx DOCX document
Marmic Fire Sprinkler Inspection Report 1.pdf PDF
combined fire alarm report.pdf PDF
2025-09-15_Fayetteville-VAMC-Bldg-2_FireScan.pdf PDF
2025-09-15_Fayetteville-VAMC-Bldg-44_FireScan.pdf PDF
2025-09-01_Fayetteville-VAMC-Bldg-6_FireScan.pdf PDF
2025-09-15_Fayetteville-VAMC-Bldg-34_FireScan.pdf PDF
2025-09-08_Fayetteville-VAMC-Bldg-40_FireScan.pdf PDF
2025-08-27_Fayetteville-VAMC-Bldg-9_FireScan.pdf PDF
2025-09-15_Fayetteville-VAMC-Bldg-21_FireScan.pdf PDF
2025-09-15_Fayetteville-VAMC-Bldg-4_FireScan.pdf PDF
2025-09-15_Fayetteville-VAMC-Bldg-29_FireScan.pdf PDF
2025-09-15_Fayetteville-VAMC-Bldg-10_FireScan.pdf PDF
2025-09-08_Fayetteville-VAMC-Bldg-5_FireScan.pdf PDF
FACTOR 2.docx DOCX document
FACTOR 1.docx DOCX document
36C25626Q0430 0001.docx DOCX document
36C25626Q0430_1.docx DOCX document
P09_SOW Fire Alarm Service.docx DOCX document
WD 2015-5109.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Table 1

VAMC Fayetteville Existing Fire Protection (FP) & Backflow Prevention Device Identification
Building NumberFloorRoom NumberDevice NumberBackflow Preventer TypeProtection Degree of HazardDevice ManufacturerSerial NumberPipe Size (Inch)PurposeDrawing Reference NumberDate of Inspection
11M1 2003(FP)Double Check DetectorLow HazardAmesI-44379-11058"Fire ProtectionN/ASept. 2016
11M1 2004(FP)Double CheckLow HazardWatts474203/4"Meter BypassN/ASept. 2016
31M4001(FP)Double Check DetectorLow HazardAmes DDCJG-05774"Fire ProtectionN/ASept. 2016
31M4002(FP)Double CheckLow HazardAmes DDC169163/4"Meter BypassN/ASept. 2016
4BasementCrawl001(FP)Double CheckLow HazardWatts21000654"Fire ProtectionN/AFeb. 2016
8GroundSprinkler Room 2001(FP)Double Check DetectorLow HazardColt 300BFJG-05774"Fire ProtectionN/ASept. 2016
8GroundSprinkler Room 2002(FP)Double CheckLow HazardWatts169103/4"Meter BypassN/ASept. 2016
9Basement001002(FP)Double Check DetectorLow HazardJG-05774"Fire ProtectionN/ASept. 2016
9Basement001003(FP)Double CheckLow HazardAames169103/4"Fire ProtectionN/ASept. 2016
2711001(FP)Double Check DetectorLow HazardWilkinsV-242204"Fire Protection (Sprinkler)N/ASept. 2016
2711002(FP)Double CheckLow HazardWatts33360923/4"Meter BypassN/ASept. 2016
291SP004001(FP)Double Check DetectorLow HazardWilkinsV-249054"Fire Protection (Sprinkler)N/ASept. 2016
291SP004002(FP)Double CheckLow HazardWatts32173453/4"Meter BypassN/ASept. 2016
341N/A001(FP)Double Check DetectorLow HazardJC-05734"Fire ProtectionN/ASept. 2016
341N/A002(FP)Double CheckLow Hazard169563/4"Fire ProtectionN/ASept. 2016
441124B003(FP)Double Check DetectorLow Hazard200266-04026"Fire ProtectionN/ASept. 2016
441124B004(FP)Double CheckLow Hazard532613/4"Fire ProtectionN/ASept. 2016
1BasementMB05001Red. Pressure PrincipalHigh HazardWatts 757aDC-03244"Domestic WaterPL-101Sept. 2016
1BasementMB10001Red. Pressure PrincipalHigh HazardZurn-Wilkins 375XLL-697234"Domestic WaterPL-110Sept. 2016
1BasementMB10002Red. Pressure PrincipalHigh HazardZurn-Wilkins 975XL35348122"Irrigation CW Feed w/ meterPL-110Sept. 2016
1BasementMB10003Red. Pressure PrincipalHigh HazardZurn-Wilkins 975XL35332361"Humidifier CW FeedPL-110Sept. 2016
1BasementPC43001Red. Pressure PrincipalHigh HazardWatts 0095722743/4"HVAC CW FeedPL-101Sept. 2016
11M1 2001Red. Pressure PrincipalHigh HazardFebcoJ-0429863/4"Humidifier CW FeedPL-104Sept. 2016
11M1 2002Red. Pressure PrincipalHigh HazardWatts 009A150021"HVAC CW FeedPL-104Sept. 2016
11PC105001Red. Pressure PrincipalHigh HazardCombracoW 34743/4"HVAC CW FeedPL-110Sept. 2016
12M2 1001Red. Pressure PrincipalHigh HazardZurn-Wilkins 975XL34319333/4"Humidifier CW FeedPL-105Sept. 2016
12M2 2001Red. Pressure PrincipalHigh HazardZurn29193521"HVAC CW FeedPL-106Sept. 2016
12M2 3001Red. Pressure PrincipalHigh HazardFebcoJ-0929813/4"Humidifier CW FeedPL-106Sept. 2016
12231001Red. Pressure PrincipalHigh HazardZurn-Wilkins38375671"Sterilization equip.PL-105Sept. 2016
12231002Red. Pressure PrincipalHigh HazardZurn-Wilkins37948021"Sterilization equip.PL-105Sept. 2016
12231003Red. Pressure PrincipalHigh HazardZurn-Wilkins36322393/4"Sterilization equip.PL-105Sept. 2016
12M2 4001Red. Pressure PrincipalHigh HazardFebco 825YJ-0452383/4"Humidifier CW FeedPL-105Sept. 2016
14407001Red. Pressure PrincipalHigh HazardZurn-Wilkins 975XL24190183/4"HVAC CW FeedPL-109Sept. 2016
14418001Red. Pressure PrincipalHigh HazardZurn-Wilkins 975XL13587871"CW to HVAC & HumidifierPL-109Sept. 2016
1Attic502001Red. Pressure PrincipalHigh HazardZurn-Wilkins 375RPA2308543/4"Humdifier CW feedPL-109Sept. 2016
211127001Red. Pressure PrincipalHigh HazardZurn-Wilkins 375XLL-287163"Domestic WaterPL-114Sept. 2016
211127002Red. Pressure PrincipalHigh HazardZurn-Wilkins 375XLL-293703"Domestic WaterPL-114Sept. 2016
211127003Red. Pressure PrincipalHigh HazardZurn-Wilkins 975XL1288251"HVAC & HumidifierPL-114Sept. 2016
211188001Red. Pressure PrincipalHigh HazardZurn-Wilkins 975XL32244611 1/4"Emergency SupplyPL-111Sept. 2016
211188002Red. Pressure PrincipalHigh HazardZurn-Wilkins 975XL241412283/4"HVAC CW FeedPL-111Sept. 2016
4BasementMB1001Red. Pressure PrincipalHigh HazardWatts281663/4"HVAC CW FeedPL-117Feb. 2016
9Basement001001Red. Pressure PrincipalHigh HazardZurn Wilkins 975XL34574371"Feeding Bldg 40PL-123Sept. 2016
9Basement002001Red. Pressure PrincipalHigh HazardZurn Wilkins 975XL22015032"CW to wash waterPL-123Sept. 2016
101001001Red. Pressure PrincipalHigh HazardWatts 9091825184"Domestic CW Feed to TowerPL-125Sept. 2016
101001002Red. Pressure PrincipalHigh HazardWatts 9091825234"Domestic CW Feed to TowerPL-125Sept. 2016
101001003Red. Pressure PrincipalHigh HazardZurn Wilkins 975XLW1219762"CW to soft water & fixturesPL-125Sept. 2016
181001001Red. Pressure PrincipalHigh HazardZurn2784C3"Non-Potable WaterPL-126Sept. 2016
21Lower LevelL220A001Red. Pressure PrincipalHigh HazardZurn-WilkinsL700234"Domestic feedPL-130Feb. 2016
21Lower LevelL220A002Red. Pressure PrincipalHigh HazardZurn Wilkins35332401"Dental Equip.PL-130Feb. 2016
213Penthouse001Red. Pressure PrincipalHigh HazardZurn-Wilkins3585191 1/2"HVAC CW FeedPL-137Feb. 2016
291SP001001Red. Pressure PrincipalHigh HazardWatts 9091221112-1/2"Tower Cooling Make UpPL-138Sept. 2016
291SP002001Red. Pressure PrincipalHigh HazardApollo RP402386442"Chilled Water Make UpPL-138Sept. 2016
401001001Double CheckHigh Hazard3123021"IncineratorPL-140Sept. 2016
441124B001Red. Pressure PrincipalHigh HazardZurn-Wilkins13015321 1/4"Hose ConnectionPL-141Sept. 2016
441124B002Red. Pressure PrincipalHigh HazardZurn-WilkinsW0350693/4"Hose ConnectionPL-141Sept. 2016