This document contains a federal solicitation for construction services and products to renovate an outpatient mental health clinic. The solicitation is available only to verified Service-Disabled Veteran-Owned Small Businesses and involves general construction including demolition and renovation of approximately 28,000 square feet of existing space at the Coatesville VA Medical Center in Coatesville, Pennsylvania. The scope of work includes renovating the west basement wing and first and second floors of Building 4 along with associated basement and attic work. Additional work comprises construction of a new elevator and shaft at the front exterior of the building plus exterior improvements. Disciplines for the project consist of site, civil, structural, hazardous materials, architectural, fire protection, mechanical, plumbing, and electrical. The solicitation documents and drawings will be available for download from the Contracting Opportunities website on or about June 23, 2020. The bid due date and opening will be included in the solicitation. Award of a firm fixed price contract is subject to FY20 funds availability. The maximum completion time is 588 calendar days from notice to proceed.
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Coatesville VA Medical Center
Coatesville, Pennsylvania 19320
Renovate Building 4 A & B Floors Outpatient Mental Health Clinic
Bancroft Architects + Engineers
12-01-15
Contract No. 36C24418C0144
Station Project No. 542-18-106
Bancroft-AE Project No. 18-102 10 21 13-1 08-03-2020
SECTION 10 21 13
TOILET COMPARTMENTS
PART 1 - GENERAL
1.1 DESCRIPTION
This Section specifies metal toilet partitions and urinal screens.
1.2 RELATED WORK
A. Not used.
B. Not used.
C. Grab bars and toilet tissue holders: Section 10 28 00, TOILET, BATH, AND LAUNDRY ACCESSORIES.
1.3 SUBMITTALS
A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT
DATA, AND SAMPLES.
B. Samples: Prime coat of paint on 150 mm (six inch) square of metal panel with baked enamel finish coat over half of panel.
C. Manufacturer's Literature and Data: Specified items indicating all hardware and fittings, material, finish, and latching.
D. Shop Drawings: Construction details at 1/2 scale, showing installation details, anchoring and leveling devices.
E. Manufacturer's certificate, attesting that zinc-coatings conform to specified requirements.
1.4 APPLICABLE PUBLICATIONS
A. Publications listed below form a part of this specification to the extent referenced. Publications are referenced in the text by the basic designation only.
B. Federal Specifications (Fed. Spec.):
FF-B-575C...............Bolt, Hexagon and Square
C. Code of Federal Regulations (CFR):
40 CFR 247..............Comprehensive Procurement Guidelines for
Products Containing Recovered Materials
D. Commercial Item Descriptions (CID):
A-A-1925 Shield, Expansion (Nail Anchors)A-A-60003 Partitions, Toilet, Complete
Renovate Building 4 A & B Floors Outpatient Mental Health Clinic
Bancroft-AE Project No. 18-102 10 21 13-2 08-03-2020
PART 2 - PRODUCTS
2.1 TOILET PARTITIONS
A. Metal; graffiti resistant; non-absorbent; Class C flame spread rating.
B. Conform to Fed. Spec. CID A-A-60003, except as modified herein.
C. Fabricate to dimensions shown or specified.
D. Toilet Enclosures:
1. Type 1, Style A (Floor supported).
2. Not used.
3. Reinforce panels shown to receive toilet tissue holders or grab bars.
4. Upper pivots and lower hinges adjustable to hold doors open 30 degrees.
5. Latching devices and hinges for handicap compartments shall comply with ADA requirements.
6. Keeper:
a. U-slot to engage bar of throw latch.
b. Combined with rubber bumper stop.
7. Wheelchair Toilets:
a. Upper pivots and lower hinges to hold out swinging doors in closed position.
b. Provide U-type doors pulls, approximately 100 mm (four inches) long on pull side.
8. Finish:
a. Stainless Steel.
E. Urinal Screens:
1. Type III, Style E (wall hung), stainless steel.
a. With integral flanges and continuous, full height wall anchor plate.
b. Option: Full height U-Type bracket.
c. Wall anchor plate drilled for 4 anchors on both sides of screen.
2. Screen 600 mm (24 inches) wide and 1060 mm (42 inches high).
3. Not used.
F. Room Entrance Screens: NOT USED.
Renovate Building 4 A & B Floors Outpatient Mental Health Clinic
Bancroft-AE Project No. 18-102 10 21 13-3 08-03-2020
G. Toilet Partition products shall comply with following standards for biobased materials:
Material Type Percent by Weight
Phenolic Partition 55 percent biobased material
The minimum-content standards are based on the weight (not the volume) of the material in the insulating core only.
2.2 FASTENERS
A. Partition Fasteners: CID A-A-60003.
B. Use expansion bolts, CID A-A-60003, for anchoring to solid masonry or concrete.
C. Use toggle bolts, CID A-A-60003, for anchoring to hollow masonry or stud framed walls.
D. Use steel bolts FS-B-575, for anchoring pilasters to overhead steel supports.
E. Fasteners used shall be tamper resistant.
PART 3 - EXECUTION
3.1 INSTALLATION
A. General:
1. Install in rigid manner, straight, plumb and with all horizontal lines level.
2. Conceal evidence of drilling, cutting and fitting in finish work.
3. Use hex-bolts for through-bolting.
4. Adjust hardware and leave in freely working order.
5. Clean finished surfaces and leave free of imperfections.
B. Panels and Pilasters:
1. Support panels, except urinal screens, and pilaster abutting building walls near top and bottom by stirrup supports secured to partitions with through-bolts.
2. Secure stirrups to walls with two suitable anchoring devices for each stirrup.
3. Secure panels to faces of pilaster near top and bottom with stirrup supports, through-bolted to panels and machine screwed to each pilaster.
Renovate Building 4 A & B Floors Outpatient Mental Health Clinic
Bancroft-AE Project No. 18-102 10 21 13-4 08-03-2020
4. Secure edges of panels to edges of pilasters near top and bottom with "U" shaped brackets.
//5. Where overhead braced, secure pilasters to building walls by headrails clamped on or set into top of each pilaster.
a. Secure clamps to pilasters with two through-bolts to each clamp.
b. When headrails are set into pilasters, through-bolt them to the pilasters.
c. Support headrails on wall flange fittings secured to building walls with minimum of two anchor bolts to each flange fitting. //
C. Urinal Screens:
1. Anchor urinal screen flange to walls with minimum of four bolts both side of panel.
2. Space anchors at top and bottom and equally in between.
- - - E N D - - -