06 Interiors 54218106_Drawings_FinalCD_013120.pdf
PDF 6 MB Posted
- Attached to
- Z2DA--Renovate Building 4 A + B Floors Outpatient Mental Health Clinic, Project No. 542-18-106
- Solicitation number
- 36C24420B0003
About this file
This federal contract opportunity solicitation is for the renovation of Building 4A & B Floors at the VA Medical Center in Coatesville, PA to create an Outpatient Mental Health Clinic. The project involves demolishing approximately 28,000 square feet of existing space on the 1st and 2nd floors and renovating it into new outpatient clinics for the Mental Health Department. An additional 3,000 square feet in the basement wing will also be renovated. Scope of work includes construction of a new elevator and shaft at the front of the building, along with site work, structural work, hazardous material abatement, architectural finishes, fire protection, mechanical, plumbing and electrical systems.
The solicitation will be available for download on/after June 23, 2020 from SAM.gov. Interested Service-Disabled Veteran-Owned Small Businesses must be CVE verified and meet OSHA/EPA requirements. The contract will be awarded on a Firm Fixed Price basis to the responsible bidder submitting the lowest priced, technically acceptable offer. The period of performance is 588 calendar days from notice to proceed. Bid due/opening dates will be included in the solicitation. Bidders must be able to provide 100% payment and performance bonds and a 20% bid guarantee.
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
31 JAN 2020
FINISH SCHEDULE - BASEMENT
AND FIRST FLOOR
RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
PB DM
542-18-106
I601
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
ROOM FINISH SCHEDULE - BASEMENT AND FIRST FLOOR
ROOM
NO. ROOM NAME
FLOOR BASE WALLS CEILING
REMARKS
FLOOR
MATERIAL
FLOOR
COLOR
BASE
MATERIAL BASE COLOR
NORTH WEST SOUTH EAST
TYPE HEIGHTSMATERIAL FINISH COLOR MATERIAL FINISH COLOR MATERIAL FINISH COLOR MATERIAL FINISH COLOR
BASEMENT
B01 WAITING/ BREAKOUT LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1/P-6 GWB PAINT P-1 GWB PAINT P-1/P-6 ACT-1 / GWB P-6
VARIES SEE A130.1 FOR EXACT CEILING HEIGHTS AND
FINISHES
B01A GROUP ROOM LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 ACT-1 8'-0"
B01B GROUP ROOM LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-6 ACT-1 8'-0"
B01C GROUP ROOM LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-6 ACT-1 8'-0"
B02 MEN'S RESTROOM PORCELAIN PT-1 PORCELAIN PTB-1 PORCELAIN PT PT-1 PORCELAIN PT PT-1 PORCELAIN PT PT-1 PORCELAIN PT PT-1 GWB/P-7 8'-0" SEE A130.1 FOR EXACT CEILING HEIGHT AND
FINISHES / SEE INTERIOR ELEVATIONS FOR
WALL FINISH DETAILS
B02A WOMEN'S RESTROOM PORCELAIN PT-2 PORCELAIN PTB-2 PORCELAIN PT PT-2 PORCELAIN PT PT-2 PORCELAIN PT PT-2 PORCELAIN PT PT-2 GWB/P-7 8'-0" SEE A130.1 FOR EXACT CEILING HEIGHT AND
FINISHES / SEE INTERIOR ELEVATIONS FOR
WALL FINISH DETAILS
B03 GROUP ROOM LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-6 ACT-1 8'-0"
B03A GROUP ROOM LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-6 ACT-1 8'-0"
B03B STORAGE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 8'-0"
B03C ELECTRICAL CLOSET SS CS-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 8'-0"
B03D STORAGE QUARTZ QT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 8'-0"
B04 LACTATION ROOM LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 ACT-1 8'-0"
B16B ELEVATOR SERVICE ROOM 2 SS CS-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1
1st FLOOR
100 VESTIBULE WCPT CT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9' 9 3/4"
100A WAITING/ BREAK-OUT LVT LVT-1 VINYL VB-1 GWB PAINT P-2/P-6 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-6 ACT-1 9'-0"
100B WHEELCHAIR ALCOVE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
100C CENTER CORRIDOR LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
100E EAST CORRIDOR LVT LVT-1 VINYL VB-1 GWB PAINT P-6 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 ACT-1/GWB P-6
VARIES SEE A131.3 FOR EXACT CEILING HEIGHTS AND
FINISHES
100W WEST CORRIDOR LVT LVT-1 VINYL VB-1 GWB PAINT P-6 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 ACT-1/GWB P-6
VARIES SEE A131.1 FOR EXACT CEILING HEIGHTS AND
FINISHES
101 WOMENS WAITING LVT LVT-2 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
102 ELEC SS CS-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 EXIST'G 9'-0"
103 TOILET PORCELAIN PT-1 PT PTB-1 PORCELAIN PT PT-1 PORCELAIN PT/PAINT PT-1 PORCELAIN PT PT-1 PORCELAIN PT PT-1 GWB/P-7 8'-0" SEE A131.3 FOR EXACT CEILING FINISHES / SEE
INTERIOR ELEVATIONS FOR WALL FINISH
DETAILS
104 TOILET PORCELAIN PT-2 PT PTB-2 PORCELAIN PT PT-2 PORCELAIN PT/PAINT PT-2 PORCELAIN PT PT-2 PORCELAIN PT PT-2 GWB/P-7 8'-0" SEE A131.3 FOR EXACT CEILING FINISHES / SEE
INTERIOR ELEVATIONS FOR WALL FINISH
DETAILS
105 COLLABORATIVE ROOM CPT CT-2 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 ACT-1 9'-0"
105A SUPERVISOR LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-4 ACT-1 9'-0"
106 MENTAL HEALTH CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-4 ACT-1 9'-0"
107 MENTAL HEALTH EXAM ROOM LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-5 ACT-1 9'-0"
108 MENTAL HEALTH CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-5 ACT-1 9'-0"
109 MENTAL HEALTH CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-5 ACT-1 9'-0"
110 MENTAL HEALTH EXAM ROOM LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-5 ACT-1 9'-0"
111 MENTAL HEALTH CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 ACT-1 9'-0"
112 PRIMARY CARE EXAM ROOM LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-5 ACT-1 9'-0"
113 PRIMARY CARE EXAM ROOM LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-5 ACT-1 9'-0"
114 SUPPLY LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-5 ACT-1 9'-0"
114A CRASH CART LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
115 PRIMARY CARE EXAM ROOM LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-5 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
116 PRIMARY CARE EXAM ROOM LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-5 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
117 PRIMARY CARE EXAM ROOM LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-5 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
118 PRIMARY CARE EXAM ROOM QUARTZ QT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
119 MEDS QUARTZ QT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
119A STORAGE QUARTZ QT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 EXIST'G
119B STORAGE QUARTZ QT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 EXIST'G
120 GROUP ROOM CPT CT-2 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 ACT-1 9'-0"
120A EAST STAIR EXIST'G EXIST'G EXIST'G EXIST'G PAINT EXIST'G PAINT EXIST'G PAINT EXIST'G
121 CHECK-IN CLERKS LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 ACT-1 / GWB P-6
VARIES SEE A131.3 FOR EXACT CEILING FINISHES
121A CLERK AREA LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 ACT-1 8'-0"
122 SUPERVISOR OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 ACT-1 9'-0"
123 STAFF ROOM LVT LVT-3 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 ACT-1 9'-0"
124 TOILET PORCELAIN PT-1 PT PTB-1 PORCELAIN PT/PAINT PT-1 PORCELAIN PT/PAINT PT-1 PORCELAIN PT/PAINT PT-1 PORCELAIN PT/PAINT PT-1 GWB 9'-0" SEE A131.2 FOR EXACT CEILING FINISHES
125 TOILET PORCELAIN PT-2 PT PTB-2 PORCELAIN PT/PAINT PT-2 PORCELAIN PT/PAINT PT-2 PORCELAIN PT/PAINT PT-2 PORCELAIN PT/PAINT PT-2 GWB 9'-0" SEE A131.2 FOR EXACT CEILING FINISHES
126 PSYCHIATRIC CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
127 STOR/ EMS QUARTZ QT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB 9'-0"
128 PSYCHIATRIC CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
129 PSYCHIATRIC CONSULT OFFICE CPT CT-2 VINYL VB-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
129A WEST STAIR EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G
130 PSYCHIATRIC CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
131 PSYCHIATRIC CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
132 TOILET PORCELAIN PT-2 PT PTB-2 PORCELAIN PT PT-2 PORCELAIN PT PT-2 PORCELAIN PT PT-2 PORCELAIN PT PT-2 GWB 9'-0" SEE A131.2 FOR EXACT CEILING FINISHES / SEE
INTERIOR ELEVATIONS FOR WALL FINISH
DETAILS
133 TOILET PORCELAIN PT-1 PT PTB-1 PORCELAIN PT PT-1 PORCELAIN PT PT-1 PORCELAIN PT PT-1 PORCELAIN PT PT-1 GWB 9'-0" SEE A131.2 FOR EXACT CEILING FINISHES / SEE
INTERIOR ELEVATIONS FOR WALL FINISH
DETAILS
134 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-4 ACT-1 9'-0"
135 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-4 ACT-1 9'-0"
136 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
137 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
138 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
139 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
140 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
141 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
142 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
143 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
144 SUPERVISOR OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
145 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
146 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
147 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
148 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-4 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
149 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-4 GWB PAINT P-1 ACT-1 9'-0"
150 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-4 GWB PAINT P-1 ACT-1 9'-0"
151 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 ACT-1 9'-0"
152 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 ACT-1 9'-0"
153 PSYCH/SOCIAL CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 ACT-1 9'-0"
154 IT QUARTZ QT-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0" SEE A131.1 FOR EXACT CEILING FINISHES
Revisions: Date:
50% CONSTRUCTION DOCUMENTS SUBMISSION 16 APR 2019
MOD - 50% CONSTRUCTION DOCUMENTS SUBMISSION 21 JUN 2019
100% CONSTRUCTION DOCUMENTS SUBMISSION 3 JAN 2020
FINAL CONSTRUCTION DOCUMENTS SUBMISSION 31 JAN 2020
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
31 JAN 2020
FINISH SCHEDULE AND
LEGEND - SECOND FLOOR
RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
PB DM
542-18-106
I602
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
ROOM FINISH SCHEDULE - SECOND FLOOR
ROOM
NO. ROOM NAME
FLOOR BASE WALLS CEILING
REMARKS
FLOOR
MATERIAL
FLOOR
COLOR
BASE
MATERIAL
BASE
COLOR
NORTH WEST SOUTH EAST
TYPE HEIGHTMATERIAL FINISH COLOR MATERIAL FINISH COLOR MATERIAL FINISH COLOR MATERIAL FINISH COLOR
2nd FLOOR
200A WAITING/ BREAK-OUT LVT LVT-1/2 VINYL VB-1 GWB PAINT P-2/P-6 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-1 ACT-1 9'-0"
200C CENTER CORRIDOR LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
200E EAST CORRIDOR LVT LVT-1 VINYL VB-1 GWB PAINT P-6 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 / GWB P-6
VARIES SEE A132.3 FOR EXACT CEILING HEIGHTS AND
FINISHES
200W WEST CORRIDOR LVT LVT-1 VINYL VB-1 GWB PAINT P-6 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 ACT-1 / GWB P-6
VARIES SEE A132.1 FOR EXACT CEILING HEIGHTS AND
FINISHES
201 CONSULT CPT CT-2 VINYL VB-1 GWB PAINT P-4 GWB PAINT P-4 GWB PAINT P-4 GWB PAINT P-1 ACT-1 9'-0"
202 WOMENS WAITING LVT LVT-2 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
203 ELEC QUARTZ QT-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 EXIST'G
204 TOILET PORCELAIN PT-1 PORCELAIN PTB-1 PORCELAIN PT PT-1 PORCELAIN PT PT-1 PORCELAIN PT/PAINT PT-1 PORCELAIN PT PT-1 GWB/P-7 8'-0" SEE A132.3 FOR EXACT CEILING FINISHES
205 TOILET PORCELAIN PT-2 PORCELAIN PTB-2 PORCELAIN PT PT-2 PORCELAIN PT PT-2 PORCELAIN PT/PAINT PT-2 PORCELAIN PT PT-2 GWB/P-7 8'-0" SEE A132.3 FOR EXACT CEILING FINISHES
206 NEURO PSYCH/ TESTING LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
206A STORAGE QUARTZ QT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 8'-0"
207 NEURO PSYCH/ TESTING LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 ACT-1 9'-0"
208 NEURO PSYCH/ TESTING LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 ACT-1 9'-0"
209 NEURO PSYCH/ TESTING LVT LVT-1 VINYL VB-1 GWB PAINT P-4 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
210 NEURO PSYCH/ TESTING LVT LVT-1 VINYL VB-1 GWB PAINT P-4 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
210A STORAGE QUARTZ QT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 8'-0"
211 NEURO PSYCH/ TESTING LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
212 NEURO PSYCH/ TESTING LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
213 NEURO PSYCH/ TESTING LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
213A STORAGE QUARTZ QT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 EXIST'G
213B STORAGE QUARTZ QT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 EXIST'G
214 GROUP THERAPY CPT CT-2 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 ACT-1 9'-0"
214A EAST STAIR EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G
215 CHECK-IN CLERKS LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 ACT-1 8'-0"
215A NURSE/ TRIAGE LVT LVT-1 VINYL VB-1 GWB PAINT P-3 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 ACT-1 8'-0"
216 TOILETS PORCELAIN PT-1 PORCELAIN PTB-1 PORCELAIN PT PT-1 PORCELAIN PT PT-1 PORCELAIN PT PT-1 PORCELAIN PT PT-1 GWB/P-7 8'-0" SEE A132.3 FOR EXACT CEILING FINISHES /
SEE INTERIOR ELEVATIONS FOR WALL FINISH
DETAILS
217 TOILETS PORCELAIN PT-2 PORCELAIN PTB-2 PORCELAIN PT PT-2 PORCELAIN PT PT-2 PORCELAIN PT PT-2 PORCELAIN PT PT-2 GWB/P-7 8'-0" SEE A132.4 FOR EXACT CEILING FINISHES /
SEE INTERIOR ELEVATIONS FOR WALL FINISH
DETAILS
218 STAFF ROOM LVT LVT-3 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 GWB PAINT P-6 ACT-1 9'-0"
219 VJO / TCM / TBI LVT LVT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 GWB PAINT P-6 ACT-1 9'-0"
219A WEST STAIR EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G
219B HAC EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G EXIST'G
220 SUD CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-4 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
221 SUD CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-4 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
222 TOILET PORCELAIN PT-2 PORCELAIN PTB-2 PORCELAIN PT PT-2 GWB PT PT-2 PORCELAIN PT PT-2 PORCELAIN PT PT-2 GWB/P-7 8'-0" SEE A132.2 FOR EXACT CEILING FINISHES
223 TOILET PORCELAIN PT-1 PORCELAIN PTB-1 PORCELAIN PT PT-1 GWB PT PT-1 PORCELAIN PT PT-1 PORCELAIN PT PT-1 GWB/P-7 8'-0" SEE A132.2 FOR EXACT CEILING FINISHES
224 BIO-FEEDBACK TREATMENT LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 ACT-1 9'-0"
225 BIO-FEEDBACK DR. PEKALA LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 ACT-1 9'-0"
226 BIO-FEEDBACK INTAKE AND
WAITING
LVT LVT-1 VINYL VB-1 GWB PAINT P-6 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 ACT-1 9'-0"
226A BIO-FEEDBACK INTAKE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 ACT-1 9'-0"
226B STORAGE QUARTZ QT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 8'-0"
227 BIO-FEEDBACK DANIELLE LVT LVT-1 VINYL VB-1 GWB PAINT P-4 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
228 BIO-FEEDBACK OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-4 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 ACT-1 9'-0"
229 SUD CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 ACT-1 9'-0"
230 SUD CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 ACT-1 9'-0"
230A STORAGE QUARTZ QT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 8'-0"
231 SUD CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 ACT-1 9'-0"
232 SUD CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 ACT-1 9'-0"
233 SUD CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 ACT-1 9'-0"
234 IT QUARTZ QT-1 VINYL VB-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 EXIST'G
235 ELEC QUARTZ QT-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 EXIST'G
236 SUD CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 ACT-1 9'-0"
237 SUD CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 ACT-1 9'-0"
238 SUD CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 ACT-1 9'-0"
239 HOTEL CONSULT LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 ACT-1 9'-0"
240 HOTEL CONSULT LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 ACT-1 9'-0"
241 CONFERENCE CPT CT-2 VINYL VB-1 GWB PAINT P-6 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 ACT-1 9'-0"
ROOM FINISH LEGEND
Key Material Manufacturer/Design Basis Product Properties Style/Color (Or Approved Equal) Contact
Miscellaneous Finishes
1 GROUT (PT-1/3) BOSTIK or VA Approved Equal PRE-MIXED/UREATHANE H145/COLOR: MOBE PEARL DARLENE COZZI (847) 561-9582
2 GROUT (PT-2) BOSTIK or VA Approved Equal PRE-MIXED/UREATHANE H144/COLOR: PORTABELLA DARLENE COZZI (847) 561-9582
3 WOOD DOORS VT DOORS or VA Approved Equal SPECIES: RED OAK/COLOR:
CLEAR, CL18
MARK REUSCG (712) 369-0747
4 SIGNAGE TAKEFORM or VA Approved Equal CAMBER COLLECTION/FUSION
20/COLORS & GRAPHICS: TBD
BY VA
5 MILLWORK MIDMARK or VA Approved Equal SYNTHESIS CABINETRY
COLLECTION/SERENITY DOOR
STYLE/PATH WOODGRAIN
LAMINATE/S/M/L GLOVE BOX
HOLDERS IN UPPER CABINET
DOOR
6 MILLWORK HARDWARE 4" PULL/BRUSHED SATIN
7 INTEGRATED LAVATORY (BASEMENT
TOILETS)
CORIAN or VA Approved Equal STYLE: 815P/COLOR: GROUP B
- GLACIER WHITE
ROOM FINISH LEGEND
Key Material Manufacturer/Design Basis Product Properties Style/Color (Or Approved Equal) Contact
Flooring
CT-2 CARPET TILE TARKETT or VA Approval Equall MODULAR ER3 / ETHOS
MODULAR W/ OMNICOAT
TECHNOLOGY - TARKETT
TAUPE
DOUBLE BOULCE/COLOR:
COOL GRAPHITE/SIZE: 18" X
36"
LAURIE LANGE (847) 814-9806
CT-3 ENTRY WALK-OFF/FOOT GRILL
(ALTERNATIVE)
MAT'S INC or VA Approved Equal 5/16" FLEXIBLE VINYL GRID
WITH NYLON FIBER INSERTS
ULTRA ENTRY/LOOSE LAY
WITH SCHLUTER
FRAME/COLOR:TBD
RICH RUHLIN (207) 450-0462
LVT-1 LUXURY VINYL TILE TARKETT or VA Approval Equal 32 MIL WEAR LAYER/3 MM
OVERALL
THICKNESS/SQUARE EDGE
(SE)
PCEX-3324-TK/STYLE:EXOTIC
WOOD PCEX/COLOR:WASHED
TEAK/SIZE 6"X36"
LAURIE LANGE (847) 814-9806
LVT-2 LUXURY VINYL TILE TARKETT or VA Approval Equal 32 MIL WEAR LAYER/3 MM
OVERALL
THICKNESS/SQUARE EDGE
(SE)
PCCH 0974-QU/STYLE:
CHENILLE/COLOR:
PEPPERED/SIZE 6"X36"
LAURIE LANGE (847) 814-9806
LVT-3 LUXURY VINYL TILE TARKETT or VA Approval Equal 32 MIL WEAR LAYER/3 MM
OVERALL
THICKNESS/SQUARE EDGE
(SE)
ITEM: PCBC-0990-QU/STYLE:
BROADCOLTH/COLOR:
BLEACHFIELD/SIZE 6" X
36"/QUARTER TURN
INSTALLATION
LAURIE LANGE (847) 814-9806
PT-1 PORCELAIN TILE CROSSVILLE or VA Approved Equal PORCELAIN NOTORIOUS NTR03/COLOR:
SUGAR DADDY UPS/ 12 X 14
DARLENE COZZI (847) 561-9582
PT-2 PORCELAIN TILE CROSSVILLE or VA Approved Equal PORCELAIN NOTORIOUS NTR02/COLOR:
PRIVATE EYE UPS/12 X 24
DARLENE COZZI (847) 561-9582
QT-1 QUARTZ TILE RICKETT or VA Approved Equal 79% Quartz Tile/ 2.5mm SIZE: 24" X 24" TILE/ STYLE:
RAIN / COLOR: SILVER SPIRIT
HARRY BROWNETT (908)
872-0887
TS-1 TRANSITION STRIP (PT TO LVT OR CPT) SCHLUTER SYSTEMA or Approved Equal STAINLESS STEEL SCHIENE/E100-V4A/3/8" DARLENE COZZI (847) 561-9582
TS-2 TRANSITION STRIP (CPT TO LVT) TARKETT or Approved Equal VINYL SLIM LINE
TRANSITIONS/SLT-55-A/1/4" TO
1/8" SILVER GREY (CARPET TO
LVT)
KIM MATRANGA 224-287-1509
Wall Base
PTB-1 PORCELAIN TILE BASE CROSSVILLE or VA Approved Equal PORCELAIN TILE / 3/8" THICK NOTORIOUS NTR03/COLOR:
SUGAR DADDY UPS/ 6" X 12"
DARLENE COZZI (847) 561-9582
PTB-2 PORCELAIN TILE BASE CROSSVILLE or VA Approved Equal PORCELAIN TILE / 3/8" THICK NOTORIOUS NTR02/COLOR:
PRIVATE EYE UPS/ 6" X 12"
DARLENE COZZI (847) 561-9582
VB-1 VINYL BASE ARMSTRONG or Approved Equal 6"/ TOE BASE/ 1/8" THICK COLOR: FRESH TAUPE 64 KIM MATRANGA 224-287-1509
VB-2 VINYL BASE ARMSTRONG or Approved Equal 6"/ TOELESS BASE/ CARPET
TILE/ 1/8" THICK
COLOR: FRESH TAUPE 64 KIM MATRANGA 224-287-1509
Wall Finish
P-1 PAINT SHERWIN WILLIAMS or VA Approved Equal EGG SHELL/MPI-53-X-GREEN PRO MAR 200 ZERO VOC
INTERIOR LATEX/ EGGSHELL
FINISH/COLOR: SW 7647
CRUSHED ICE (255-C6)
JESSICA NEWELL (224)223-5180
P-2 PAINT SHERWIN WILLIAMS or VA Approved Equal EGG SHELL/MPI-53-X-GREEN PRO MAR 200 ZERO VOC
INTERIOR LATEX/ EGGSHELL
FINISH/COLOR: SW 9109
NATURAL LINEN (205-C1)
JESSICA NEWELL (224) 233-5180
P-3 PAINT SHERWIN WILLIAMS or VA Approved Equal EGG SHELL/MPI-53-X-GREEN PRO MAR 200 ZERO VOC
INTERIOR LATEX/ EGGSHELL
FINISH/COLOR: SW 6204 SEA
SALT (217-C1)
JESSICA NEWELL (224) 233-5180
P-4 PAINT SHERWIN WILLIAMS or VA Approved Equal EGG SHELL/MPI-53-X-GREEN PRO MAR 200 ZERO VOC
INTERIOR LATEX/ EGGSHELL
FINISH/COLOR: SW 6205
COMFORT GREY (217-C2)
JESSICA NEWELL (224) 233-5180
P-5 PAINT SHERWIN WILLIAMS or VA Approved Equal EGG SHELL/MPI-53-X-GREEN PRO MAR 200 ZERO VOC
INTERIOR LATEX/ EGGSHELL
FINISH/COLOR: SW 7652
MINERAL DEPOSIT (238-C4)
JESSICA NEWELL (224) 233-5180
P-6 PAINT SHERWIN WILLIAMS or VA Approved Equal EGG SHELL/MPI-53-X-GREEN PRO MAR 200 ZERO VOC
INTERIOR LATEX/ EGGSHELL
FINISH/COLOR: SW 6227
MEDITATIVE (220-C3)
JESSICA NEWELL (224) 233-5180
PT-1 PORCELAIN TILE (WALL) CROSSVILLE or VA Approved Equal PORCELAIN NOTORIOUS NTR03/COLOR:
SUGAR DADDY UPS/12X24
DARLENE COZZI (847) 561-9582
PT-2 PORCELAIN TILE (WALL) CROSSVILLE or VA Approved Equal PORCELAIN NOTORIOUS NTR02/COLOR:
PRIVATE EYE UPS/12X24
DARLENE COZZI (847) 561-9582
PT-3 PORCELAIN TILE (WALL ACCENT) CROSSVILLE or VA Approved Equal PORCELAIN YING & YANG - LOTUS
BLOSSOM - LINEAR MOSIAC
YY06/.1MIXMOS - 4468
DARLENE COZZI (847) 561-9582
Wall Protection
WP-1 RIGID VINYL ACROVYN or VA Approved Equal PVC-FREE/0.60 THICKNESS 4000/COLOR: FAWN
#196/TEXTURE: SUEDE
ALEXIS DABDOUB (224)651-7935
WP-2 CORNER GUARD ACROVYN or Approved Equal PVC-FREE STYLE: SM-20N/COLOR:
MISSION WHITE
#933/TEXTURE: SUEDE
ALEXIS DABDOUB (224)651-7935
WP-3 HANDRAILS ACROVYN or VA Approved Equal PVC-FREE HRB-4CN/COLOR: MISSION
WHITE #933/TEXTURE: SUEDE
ALEXIS DABDOUB (224)651-7935
WP-4 WALL GUARDS ACROVYN or VA Approved Equal PVC-FREE SCR-64N/8" HEIGHT X 1-1/2"
CLIP/COLOR: SLATE
#209/TEXTURE SUEDE
ALEXIS DABDOUB (224)651-7935
WP-5 RIGID VINYL (CHECK-IN) ACROVYN or VA Approved Equal PVC-FREE/0.60 THICKNESS BRUSHED SILVER 3410/SUEDE
TEXTURE
ALEXIS DABDOUB (224)651-7935
WP-6 END WALL PROTECTION ACROVYN or VA Approved Equal PVC-FREE STYLE 140D/COLOR:MISSION
WHITE #933/ TEXTURE: SUEDE
ALEXIS DABDOUB (224)651-7935
Millwork Surface
AC-1 ACRYLIC PANEL LUMICOR OR VA Approved Equal ACRYLIC / 1/2" STYLE:
KAURI/OLIVEWOOD/SATIN
FINISH FRONT & POLISHED
BACK/SCALE 3-1/2" X 3-1/2"
SANDY SMITH (847) 274-5420
PL-1 PLASTIC LAMINATE (CHECK-IN) WILSONART or VA Approved Equal HD LAMINATE/1/2" COMPACT
LAMINATE
WEBB OAK 17013K-57, ALIGNED
TEXTURE
TRACY VALLE (312) 493-5976
PL-2 PLASTIC LAMINATE (CHECK-IN) WILSONART or VA Approved Equal HD LAMINATE/1/2" COMPACT
LAMINATE
KINGSWOOD WALNUT/SATIN
FINISH FRONT & POLISHED
BACK/SCALE 3-1/2" X 3-1/2"
TRACY VALLE (312) 493-5976
SS-1 SOLID SURFACE CAMBRIA or VA Approved Equal 1/2"/QUARTZ PENDLE HIL LINDSAY MANRING (847) 284-2205
Ceilings
ACT-1 ACOUSTIC CEILING TILE ARMSTRONG or VA Approved Equal SOUND ABSORPTION 0.55 CORTEGA/ANGULAR TEGULA 704A/24" 24" X
5/8"/COLOR:WHITE
TABITHA MCCARTHY (877)
276-7876
P-6 PAINT (ACCENT SOFFIT/CEILING &
SOFFIT See RCP)
SHERWIN WILLIAMS or VA Approved Equal EGG SHELL/MPI-53-X-GREEN PRO MAR 200 ZERO VOC
INTERIOR LATEX/MATT
FINISH/COLOR: SW 6227
MEDITATIVE (220-C3)
JESSICA NEWELL (224)223-5180
P-7 PAINT (GYP BD CEILING & SOFFITS See
RCP)
SHERWIN WILLIAMS or VA Approved Equal EGG SHELL/MPI-53-X-GREEN PRO MAR 200 ZERO VOC
INTERIOR LATEX/MATT
FINISH/COLOR: SW 7551
GREEK VILLA (254-C1)
JESSICA NEWELL (224) 233-5180
NOTE:
1. ALL FINISHES TO HAVE FINAL APPROVAL BY THE VA INTERIOR DESIGNER COATESVILLE VA MEDICAL CENTER VISN 4
2. BASEMENT CORRIDOR FLOORING: MATCH EXITING VINYL TILE IN LOCATIONS DISTURBED BY CONSTRUCTION.
VA INTERIOR DESIGN COATESVILLE HAS FINAL APPROVAL FOR COLOR MATCH.
ROOM FINISH SCHEDULE - FIRST FLOOR
ROOM
NO. ROOM NAME
FLOOR BASE WALLS CEILING
REMARKS
FLOOR
MATERIAL
FLOOR
COLOR
BASE
MATERIAL BASE COLOR
NORTH WEST SOUTH EAST
TYPE HEIGHTSMATERIAL FINISH COLOR MATERIAL FINISH COLOR MATERIAL FINISH COLOR MATERIAL FINISH COLOR
1st FLOOR
155 ELEC SS CS-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 GWB PAINT P-1 ACT-1 9'-0"
156 PSYCHIATRIC CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 ACT-1 9'-0"
157 PSYCHIATRIC EXAM LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-5 GWB PAINT P-2 ACT-1 9'-0"
158 PSYCHIATRIC CONSULT OFFICE LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-4 GWB PAINT P-2 ACT-1 9'-0"
159 PSYCHIATRIC EXAM LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-5 GWB PAINT P-2 ACT-1 9'-0"
160 PSYCHIATRIC EXAM LVT LVT-1 VINYL VB-1 GWB PAINT P-2 GWB PAINT P-2 GWB PAINT P-5 GWB PAINT P-2 ACT-1 9'-0"
161 CONFERENCE ROOM LVT CT-2 VINYL VB-1 GWB PAINT P-6 GWB PAINT P-1 GWB PAINT P-6 GWB PAINT P-1 ACT-1 9'-0"
Revisions: Date:
50% CONSTRUCTION DOCUMENTS SUBMISSION 16 APR 2019
MOD - 50% CONSTRUCTION DOCUMENTS SUBMISSION 21 JUN 2019
DO NOT
ENTER
9"
9"
5"
3/
3/ 4"
/1
6"Fire Equipment
2" 9"
6"
3/8"
1/
4" 1/
2"
3/4"
12345 Braille
3/ 8"
1/ 4"
1/8" MIN. LETTER SPACING
3"
Abcdefgh Abcdefgh
1/ 2"
3/ 4"
3/ 8"
3/ 4"
3/4" 3/4"
3"
9"
3"
3/8"
1/
4" 1/
2"
3/4"
12345 Braille
3/ 8"
1/ 4"
1/8" MIN. LETTER SPACING 3/8" MIN. CLEAR SPACE
3/8" MIN. CLEAR SPACE
3/8"
9"
1' -0
/4
1/
4" 1/
2"
3/4"
12345 Braille
3/ 8"
1/ 4"
1/8" MIN. LETTER SPACING
3"
3/ 4"
6" 3/
4"
RESTROOM1"
9"
9"
1/8"
4" 3/
4" 5/
8" 3/
4" 3/
8" 3/
4"
AUTHORIZED
PERSONNEL
ONLY
3/ 8"
3/ 4"
CL
3/8"
Abcdefgh1 3/
8"
1 1/2"2 1/2"1 1/2"
/1
6"
/1 6"
Abcdefgh1 3/
8"
/1 6"
/1
6"
Abcdefgh1 3/
8"
/1 6"
/1
6"
Abcdefgh1 3/
8"
/1 6"
/1
6"
3" 3"
3" 3"
3" 3"
1' -6
1'-8"
3/8"
Abcdefgh1 3/
8"
1 1/2"2 1/2"1 1/2"
/1
6"
/1 6"
Abcdefgh1 3/
8"
/1 6"
/1
6"
3" 3"
3" 3"
1' -0
1'-8"
Abcdefgh1 3/
8"
/1 6"
/1
6"
IN-01.31
6" = 1'-0"
TYPE D - FIRE EQUIPMENT IDENTIFICATION SIGN
IN-04.02
6" = 1'-0"
TYPE B - PRIMARY ROOM IDENTIFICATION SIGN
IN-03.01
6" = 1'-0"
TYPE A - ROOM NUMBER IDENTIFICATION SIGN
IN-09.03
6" = 1'-0"
TYPE E - RESTROOM IDENTIFICATION SIGN
IN-08.02C
6" = 1'-0"
TYPE C - RESTRICTED ACCESS SIGN
IN-14.04
6" = 1'-0"
TYPE J - WALL DIRECTIONAL SIGN IN-14.05
6" = 1'-0"
TYPE K - WALL DIRECTIONAL SIGN
IN-09.08D
6" = 1'-0"
TYPE F - PICTOGRAM AND SYMBOL
IN-07.02TYPE G - ROOM SIGN WITH INDICATOR
9"
1/8"
STAIRS
CL
/4
/4
/4
3/8"
12345 Braille
Abcdefgh
Abcdefgh
3/4"
3/4"
9"
3" 3"
1/ 4"1
/2
1/
4" 1/
2" 1/
4" 3/
4" 1/
4" 1/
4"
1/ 2"
1/ 4"
/3
3/ 4"
2"
INSTALLATION
KNOB SIDE OF DOOR, 60" TO TOP OF SIGN AND 2" OVER FROM
DOOR FRAME.
SIZE
3"H X 9"W
SIGN COMPONENTS
REFER TO
SPECIFICATIONS
GRAPHIC PROCESS
TACTILE RAISED TEXT
AND BRAILLE ON TOP
SECTION. SURFACE
APPLIED VINYL OR
INSERT IN LOWER SIGN
SECTION
COLORS
TEXT: REFER TO FINISH
PLANS
BACKGROUND: REFER TO
FINISH PLANS
TYPOGRAPHY
HELVETICA BOLD RAISED
TACTILE GRADE 2
BRAILLE DOMED
MOUNTING
DOUBLE SIDED FOAM TAPE OR SILASTIC ADHESIVE
INSTALLATION
KNOB SIDE OF DOOR, 60" TO TOP OF SIGN AND 2" OVER FROM
DOOR FRAME.
SIZE
3"H X 9"W
SIGN COMPONENTS
REFER TO
SPECIFICATIONS
GRAPHIC PROCESS
TACTILE RAISED TEXT
AND BRAILLE ON TOP
SECTION. SURFACE
APPLIED VINYL OR
INSERT IN LOWER SIGN
SECTION
COLORS
TEXT: REFER TO FINISH
PLANS
BACKGROUND: REFER TO
FINISH PLANS
TYPOGRAPHY
HELVETICA BOLD RAISED
TACTILE GRADE 2
BRAILLE DOMED
MOUNTING
DOUBLE SIDED FOAM
TAPE OR SILASTIC
ADHESIVE
SIZE
3"H X 9"W
SIGN COMPONENTS
ACRYLIC PLAQUE
GRAPHIC PROCESS
SILK-SCREENED
COLORS
TEXT: WHITE
BACKGROUND: RED
TYPOGRAPHY
HELVETICA BOLD
MOUNTING
DOUBLE SIDED FOAM
TAPE OR SILASTIC
ADHESIVE
INSTALLATION
CENTERED ON DOOR, 63"
TO TOP OF SIGN
SIZE
9"H X 9"W
SIGN COMPONENTS
ACRYLIC PLAQUE WITH
ALUMINUM BRACKET FOR
FLAG MOUNTING
GRAPHIC PROCESS
SILK-SCREENED
COLORS
TEXT AND SYMBOL:
WHITE
BACKGROUND: RED
BRACKET: ALUMINUM
TYPOGRAPHY
HELVETICA BOLD
MOUNTING
MECHANICAL FASTENERS
WITH ANCHORS
INSTALLATION
CENTERED ABOVE FIRE
EQUIPMENT CABINET
7'-0" TO BOTTOM OF
SIGN; MECHANICALLY
FASTENED TO WALL WITH
EXPANDABLE ANCHORS
AS NEEDED FOR WALL
TYPE
SIZE
12.25"H X 9"W
SIGN COMPONENTS
REFER TO
SPECIFICATIONS
GRAPHIC PROCESS
TACTILE RAISED TEXT
AND BRAILLE ON TOP
SECTION. LOWER
SECTION TO BE RAISED
GRAPHIC TACTILE
SYMBOL
COLORS
TEXT: REFER TO FINISH
PLANS
BACKGROUND: REFER TO
FINISH PLANS
TYPOGRAPHY
HELVETICA BOLD RAISED
TACTILE GRADE 2
BRAILLE DOMED
MOUNTING
DOUBLE SIDED FOAM
TAPE OR SILASTIC
ADHESIVE
INSTALLATION
ON WALL OR DOOR, 60"
TO TOP OF SIGN AND ON
DOOR, CENTER
1/8"
CL
IN-09.08
6" = 1'-0"
TYPE H - PICTOGRAM AND SYMBOL
9"
SIZE
9"H X 9"W
SIGN COMPONENTS
SIGN IS DIGITAL PRINT,
SILKSCREEN OR VINYL
APPLIED GRAPHICS
GRAPHIC PROCESS
SILK-SCREENED OR
SURFACE APPLIED VINYL
COLORS
TEXT AND SYMBOL:
BACKGROUND:
TYPOGRAPHY
HELVETICA BOLD
MOUNTING
DOUBLE SIDED FOAM
TAPE OR SILASTIC
ADHESIVE
INSTALLATION
ON WALL OR DOOR , 60"
TO TOP OF SIGN AND ON
DOOR, CENTER
SIZE
9"H X 9"W
SIGN COMPONENTS
SIGN IS DIGITAL PRINT,
SILKSCREEN OR VINYL
APPLIED GRAPHICS
GRAPHIC PROCESS
SILK-SCREENED OR
SURFACE APPLIED VINYL
COLORS
TEXT AND SYMBOL:
BACKGROUND:
TYPOGRAPHY
HELVETICA BOLD
MOUNTING
DOUBLE SIDED FOAM
TAPE OR SILASTIC
ADHESIVE
INSTALLATION
ON WALL OR DOOR, 60"
TO TOP OF SIGN AND ON
DOOR, CENTER
SIZE
9"H X 9"W
SIGN COMPONENTS
TOP SECTION RAISED
TEXT AND BRAILLE. MID
SECTION CAN BE
DIGITAL PRINT OR VINYL
APPLIED GRAPHICS.
LOWER SECTION
MOVING SLIDER WITH
GRAPHIC REVEAL
GRAPHIC PROCESS
SLIDER SECTION
SURFACE APPLIED
VINYL. TEXT BEHIND
SLIDER IS SECOND
SURFACE
COLORS
TEXT AND SYMBOL:
BACKGROUND:
TYPOGRAPHY
HELVETICA BOLD
GRADE 2 BRAILLE
MOUNTING
DOUBLE SIDED FOAM
TAPE, SILASTIC
ADHESIVE OR SCREW
6" = 1'-0"
INSTALLATION
KNOB SIDE OF DOOR, 60" TO
TOP OF SIGN AND 2" OVER
FROM DOOR FRAME
SIZE
18"H X 20"W
SIGN COMPONENTS
REFER TO
SPECIFICATIONS
GRAPHIC PROCESS
SURFACE APPLIED VINYL
COLORS
TEXT: REFER TO FINISH
PLANS
BACKGROUND: REFER TO
FINISH PLANS
TYPOGRAPHY
HELVETICA BOLD
MOUNTING
SECURE TO WALL WITH
PHYSICAL FASTENERS
INSTALLATION
ON WALL
SIZE
12"H X 20"W
SIGN COMPONENTS
REFER TO
SPECIFICATIONS
GRAPHIC PROCESS
SURFACE APPLIED VINYL
COLORS
TEXT: REFER TO FINISH
PLANS
BACKGROUND: REFER TO
FINISH PLANS
TYPOGRAPHY
HELVETICA BOLD
MOUNTING
SECURE TO WALL WITH
PHYSICAL FASTENERS
INSTALLATION
ON WALL
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
31 JAN 2020
SIGNAGE TYPES RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
PB DM
542-18-106
I620
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
Revisions: Date:
MOUNTING DETAIL 2
MOUNTING HEIGHT FOR SIGN TYPE IN-01.31.
MOUNTING DETAIL 1
MOUNTING HEIGHT FOR SIGN TYPES IN-03.01,
IN-04.02, IN-07.02, IN-09.03, IN-09.08D.
2"
FIRE
EQUIPMENT
CABINET
MOUNTING DETAIL 3 - DOOR MOUNTED
MOUNTING HEIGHT FOR SIGN TYPES IN-08.02, IN-01.01.01.
MOUNTING DETAIL 4 - WALL
MOUNTEDMOUNTING HEIGHT FOR SIGN TYPES IN-14.04,
IN-14.05.
MOUNTING DETAIL 5 - DESK/COUNTER MOUNTED
MOUNTING HEIGHT FOR SIGN TYPES IN-12.01.
MOUNTING DETAIL 3 - WALL MOUNTED
MOUNTING DETAIL 6 - WALL MOUNTED
MOUNTING HEIGHT FOR SIGN TYPES IN-02.01,
IN-02.02, IN-02.03.
IN-02.01
IN-02.03
IN-02.02
MOUNTING DETAIL 7 - WALL MOUNTED
MOUNTING HEIGHT FOR SIGN TYPES IN-02.07.
MOUNTING DETAIL 10 - WALL MOUNTED
MOUNTING HEIGHT FOR SIGN TYPES IN-14.11,
IN-14.12, IN-14.13, IN-14.14
IN-14.11
IN-14.12,
IN-14.13
IN-14.14
MOUNTING DETAIL 9- WALL MOUNTED
MOUNTING HEIGHT FOR SIGN TYPE IN-14.25
MOUNTING DETAIL 8 - DOOR
MOUNTEDMOUNTING HEIGHT FOR SIGN TYPE IN-09.08
" 6'
- 0
MOUNTING DETAIL 11 - WALL MOUNTED
MOUNTING HEIGHT FOR SIGN TYPES IN-02.02
L
1'-8"
IN-14.25
3" = 1'-0"
TYPE L - ELEVATOR LOBBY DIRECTIONAL WITH DIGITAL PRINT INSERT
5/8"
3'
- 1
3/
4" 1"
1/ 2"
1/ 2"
1"
1'
- 0
1'
- 3
" DIGITAL PRINT
"YOU ARE
HERE" MAP
SIZE
37"H X 20"W
SIGN COMPONENTS
REFER TO
SPECIFICATIONS
GRAPHIC PROCESS
DIGITAL PRINT GRAPHICS
COLORS
TEXT: REFER TO FINISH
PLANS
BACKGROUND: REFER
TO FINISH PLANS
TYPOGRAPHY
HELVETICA BOLD
MOUNTING
SECURE TO WALL WITH
PHYSICAL FASTENERS
INSTALLATION
ON WALL
1'-8"
IN-14.11-14
3" = 1'-0"
TYPE M - ENTRY DIRECTIONAL WITH DIGITAL PRINT INSERT
5/8"
3/
4" 1"
1/ 2"
1/ 2"
1"
1'
- 0
SIZE
VARIOUSH X 20"W
SIGN COMPONENTS
REFER TO
SPECIFICATIONS
GRAPHIC PROCESS
DIGITAL PRINT WITH
CLEAR LENS COVER
COLORS
TEXT: REFER TO FINISH
PLANS
BACKGROUND: REFER TO
FINISH PLANS
TYPOGRAPHY
HELVETICA BOLD
MOUNTING
SECURE TO WALL WITH
PHYSICAL FASTENERS
INSTALLATION
ON WALL
10 1/4" 1/2"
IN-12.01
3" = 1'-0"
TYPE N - CHECK-IN DIRECTIONAL WITH DIGITAL PRINT INSERT
6"
SIZE
6"H X 20"W
SIGN COMPONENTS
REFER TO
SPECIFICATIONS
GRAPHIC PROCESS
SURFACE APPLIED VINYL
COLORS
TEXT: REFER TO FINISH
PLANS
BACKGROUND: REFER TO
FINISH PLANS
TYPOGRAPHY
HELVETICA BOLD
MOUNTING
FREESTANDING
INSTALLATION
ON COUNTER OR DESK
9"
3/4"
3/ 4"
3/ 4"
1/ 2"
1/ 2"
1/ 4"
1/ 2"
1/2"
2 1/2"
IN-02.02
3" = 1'-0"
TYPE O - NO SMOKING
6"
SIZE
6"H X 20"W
SIGN COMPONENTS
ACRYLIC PLAQUE
GRAPHIC PROCESS
SILK-SCREENED
COLORS
TEXT: REFER TO FINISH
PLANS
BACKGROUND: REFER
TO FINISH PLANS
TYPOGRAPHY
HELVETICA BOLD
MOUNTING
DOUBLE SIDED FOAM
TAPE OR SILASTIC
ADHESIVE
INSTALLATION
ON COUNTER OR DESK
1' - 8"
1/8"
3/ 4"
1/
4" 3/
4" 3"
1/ 4"1/ 2"
1/ 4"
1/ 2"
IN-02.07
NOT TO SCALE
TYPE P - PATIENT RIGHTS AND RESPONSIBILITIES
24" MINIMUM
M
IN
IM
U
M
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
31 JAN 2020
SIGNAGE TYPES & MOUNTING
HEIGHTS
RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
PB DM
542-18-106
I621
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
1/2" = 1'-0"
SIGNAGE MOUNTING HEIGHT ELEVATIONS
Revisions: Date:
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
31 JAN 2020
SIGNAGE SCHEDULE RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
PB DM
542-18-106
I622
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
SIGNAGE SCHEDULE
Mark
LOCATION SIGN
Type RemarksROOM ROOM NAME Type Room ID Count
137 100W WEST CORRIDOR IN-01.31 (UNIVERSAL SYMBOL) FIRE
EQUIPMENT
1 D
138 100W WEST CORRIDOR IN-01.31 (UNIVERSAL SYMBOL) FIRE
EQUIPMENT
1 D
139 100C CENTER CORRIDOR IN-01.31 (UNIVERSAL SYMBOL) FIRE
EQUIPMENT
1 D
140 100E EAST CORRIDOR IN-01.31 (UNIVERSAL SYMBOL) FIRE
EQUIPMENT
1 D
141 100E EAST CORRIDOR IN-01.31 (UNIVERSAL SYMBOL) FIRE
EQUIPMENT
1 D
142 NEXT TO 219 NEXT TO VJO / TCM / TBI IN-01.31 (UNIVERSAL SYMBOL) FIRE
EQUIPMENT
1 D
143 200A WAITING/BREAK-OUT IN-01.31 (UNIVERSAL SYMBOL) FIRE
EQUIPMENT
1 D
144 200E EAST CORRIDOR IN-01.31 (UNIVERSAL SYMBOL) FIRE
EQUIPMENT
1 D
145 200W WEST CORRIDOR IN-01.31 (UNIVERSAL SYMBOL) FIRE
EQUIPMENT
1 D
146 200C CENTER CORRIDOR IN-01.31 (UNIVERSAL SYMBOL) FIRE
EQUIPMENT
1 D
147 100B WHEELCHAIR ALCOVE IN-04.02 WHEELCHAIR ALCOVE 1 B
148 100A WAITING/BREAK-OUT IN-04.02 CHECK-IN 1 B
149 100E EAST CORRIDOR IN-14.04 DIRECTIONAL SIGNAGE 1 J
150 100A WAITING/BREAK-OUT 14.25 ELEVATOR DIRECTIONAL 1 L
151 100A WAITING/BREAK-OUT 14.25 ELEVATOR DIRECTIONAL 1 L
152 100A WAITING/ BREAK-OUT IN-14.04 DIRECTIONAL SIGNAGE 1 J
153 100 VESTIBULE IN 02.02 NO SMOKING 1 O
154 100 VESTIBULE IN 02.07 PATIENT RIGHTS AND
RESPONSIBILITIES
1 P
155 100 VESTIBULE 14.11 DIRECTIONAL SIGNAGE 1 M
156 100C CENTER CORRIDOR IN-14.04 DIRECTIONAL SIGNAGE 1 J
157 100W DIRECTIONAL SIGNAGE IN-14.04 DIRECTIONAL SIGNAGE 1 J
158 200E EAST CORRIDOR IN-14.04 DIRECTIONAL SIGNAGE 1 J
159 200A WAITING/BREAK-OUT 14.25 ELEVATOR SIGNAGE 1 L
160 200A WAITING/BREAK-OUT IN-14.04 DIRECTIONAL SIGNAGE 1 J
161 215 CHECK-IN CLERKS IN-14.04 DIRECTIONAL SIGNAGE 1 J
162 200C CENTER CORRIDOR IN-14.04 DIRECTIONAL SIGNAGE 1 J
163 200W WEST CORRIDOR IN-14.04 DIRECTIONAL SIGNAGE 1 J
164 B02A WOMEN'S RESTROOM IN-09.08 BABY CHANGING STATION 1 H MOUNT ON
DOOR
165 B01 WAITING/BREAK-OUT IN 12.01 CHECK-IN DIRECTIONAL
SIGNAGE
1 N MOUNT ON
COUNTER
166 103 TOILET IN-09.08 BABY CHANGING STATION 1 H MOUNT ON
DOOR
167 132 TOILET IN-09.08 BABY CHANGING STATION 1 H MOUNT ON
DOOR
168 100A WAITING/BREAK-OUT IN 12.01 CHECK-IN DIRECTIONAL
SIGNAGE
1 N MOUNT ON
COUNTER
170 200A WAITING/BREAK-OUT IN 12.01 CHECK-IN DIRECTIONAL
SIGNAGE
1 N MOUNT ON
COUNTER
171 204 TOILET IN-09.08 BABY CHANGING STATION 1 H MOUNT ON
DOOR
172 222 TOILET IN-09.08 BABY CHANGING STATION 1 H MOUNT ON
DOOR
SIGNAGE SCHEDULE
Mark
LOCATION SIGN
Type RemarksROOM ROOM NAME Type Room ID Count
64 144 SUPERVISOR OFFICE IN-04.02 144 OFFICE 1 B
65 145 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 145 OFFICE 1 G
66 146 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 146 OFFICE 1 G
67 147 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 147 OFFICE
Abcdefgh
1 G
68 148 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 148 OFFICE
Abcdefgh
1 G
69 149 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 149 OFFICE 1 G
70 150 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 150 OFFICE 1 G
71 150A STORAGE IN-04.02 150A STORAGE 1 B MOUNT ON
DOOR
72 151 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 151 OFFICE 1 G
73 152 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 152 OFFICE 1 G
74 153 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 153 OFFICE 1 G
75 154 IT IN-03.01 154 1 A
76 155 ELEC IN-03.01 ELEC 1 A
77 156 PYSCHIATRIC CONSULT
OFFICE
IN-07.02 156 OFFICE 1 G
78 157 PSYCHIATRIC EXAM IN-07.02 157 EXAM 1 G
79 158 PYSCHIATRIC CONSULT
OFFICE
IN-07.02 158 OFFICE 1 G
80 159 PSYCHIATRIC EXAM IN-07.02 159 EXAM 1 G
81 160 PSYCHIATRIC EXAM IN-07.02 160 EXAM 1 G
82 161 CONFERENCE ROOM IN-07.02 161 CONFERENCE ROOM 1 G
83 201 CONSULT IN-07.02 201 CONSULT 1 G
84 202 WOMEN'S WAITING IN-04.02 WOMEN'S WAITING 1 B
85 203 ELEC IN-03.01 203 1 A
86 204 TOILET IN-09.03 204 1 E
87 205 TOILET IN-09.03 TOILET 1 E
88 206 NEURO PSYCH/TESTING IN-07.02 NEURO PSYCH/TESTING 1 G
89 206A STORAGE IN-04.02 STORAGE 1 B
90 207 NEURO PSYCH/TESTING IN-07.02 NEURO PSYCH/TESTING 1 G
91 208 NEURO PSYCH/TESTING IN-07.02 NEURO PSYCH/TESTING 1 G
92 209 NEURO PSYCH/TESTING IN-07.02 NEURO PSYCH/TESTING 1 G
93 210 NEURO PSYCH/TESTING IN-07.02 NEURO PSYCH/TESTING 1 G
94 210A STORAGE IN-04.02 STORAGE 1 B
95 211 NEURO PSYCH/TESTING IN-07.02 NEURO PSYCH/TESTING 1 G
96 212 NEURO PSYCH/TESTING IN-07.02 NEURO PSYCH/TESTING 1 G
97 213 NEURO PSYCH/TESTING IN-07.02 NEURO PSYCH/TESTING 1 G
98 213A STORAGE IN-04.02 STORAGE 1 B
99 213B STORAGE IN-04.02 STORAGE 1 B
100 214 GROUP THERAPY IN-07.02 GROUP THERAPY 1 G
101 214A STAIR IN-09.08D STAIR 1 F
102 215 CHECK-IN CLERKS IN-04.02 CHECK-IN CLERKS 1 B
102A 215 CHECK-IN CLERKS IN-08.02C DO NOT ENTER 1 C
103 215A NURSE TRIAGE IN-04.02 108 NURSE TRIAGE 1 B
103A 215A NURSE TRIAGE IN-08.02C DO NOT ENTER 1 C
104 216 TOILETS IN-09.03 216 1 E
105 217 TOILETS IN-09.03 217 1 E
106 218 STAFF ROOM IN-04.02 STAFF ROOM 1 B MOUNT ON
DOOR
107 219 VJO / TCM / TBI IN-04.02 VJO / TCM / TBI 1 B MOUNT ON
DOOR
108 219A WEST STAIR IN-04.02 STAIR 1 B
109 219B HAC IN-09.08D 220 1 F
110 220 SUD CONSULT OFFICE IN-04.02 220 OFFICE 1 B
111 221 SUD CONSULT OFFICE IN-04.02 221 OFFICE 1 B
112 222 TOILET IN-09.03 TOILET 1 E
113 223 TOILET IN-09.03 TOILET 1 E
114 224 BIO-FEEDBACK
TREATMENT
IN-07.02 224 BIO-FEEDBACK
TREATMENT
1 G
115 225 BIO-FEEDBACK DR.
PEKALA
IN-07.02 225 BIO-FEEBACK TREATMENT 1 G
116 226A BIO-FEEDBACK INTAKE IN-07.02 226A BIO-FEEDBACK
TREATMENT
1 G
117 226B STORAGE IN-04.02 226B STORAGE 1 B
118 227 BIO-FEEDBACK DANIELLE IN-07.02 227 BIO-FEEDBACK
TREATMENT
1 G
119 228 BIO-FEEDBACK OFFICE IN-07.02 228 BIO-FEEDBACK
TREATMENT
1 G
120 229 SUD CONSULT OFFICE IN-07.02 229 SUD CONSULT OFFICE 1 G
121 230 SUD CONSULT OFFICE IN-07.02 230 SUD CONSULT OFFICE 1 G
122 230A STORAGE IN-04.02 230A STORAGE 1 B
123 231 SUD CONSULT OFFICE IN-07.02 231 SUD CONSULT OFFICE 1 G
124 232 SUD CONSULT OFFICE IN-07.02 232 SUD CONSULT OFFICE 1 G
125 233 SUD CONSULT OFFICE IN-07.02 223 SUD CONSULT OFFICE 1 G
126 234 IT IN-03.01 234 1 A
127 235 ELEC IN-03.01 235 1 A
128 236 SUD CONSULT OFFICE IN-07.02 236 SUD CONSULT OFFICE 1 G
129 237 SUD CONSULT OFFICE IN-07.02 237 SUD CONSULT OFFICE 1 G
130 238 SUD CONSULT OFFICE IN-07.02 238 SUD CONSULT OFFICE 1 G
131 239 HOTEL CONSULT IN-07.02 239 HOTEL CONSULT 1 G
132 240 HOTEL CONSULT IN-07.02 240 HOTEL CONSULT 1 G
133 241 CONFERENCE IN-07.02 241 CONFERENCE 1 G
134 B01 CORRIDOR IN-01.31 (UNIVERSAL SYMBOL) FIRE
EQUIPMENT
1 D
135 100A WAITING/BREAK-OUT IN-01.31 (UNIVERSAL SYMBOL) FIRE
EQUIPMENT
1 D
136 - [NORTH CORRIDOR] IN-01.31 (UNIVERSAL SYMBOL) FIRE
EQUIPMENT
1 D
SIGNAGE SCHEDULE
Mark
LOCATION SIGN
Type RemarksROOM ROOM NAME Type Room ID Count corner guard 1
LACTATION
ROOM
CABINETS
100A WAITING/BREAK-OUT 14.25 ELEVATOR DIRECTIONAL 1 L
200A WAITING/BREAK-OUT IN-14.04 DIRECTIONAL SIGNAGE 1 J
1 B01A GROUP ROOM IN-07.02 B01A GROUP ROOM
GROUP ROOM
1 G
2 B01B GROUP ROOM IN-07.02 B01B GROUP ROOM 1 G
3 B01C GROUP ROOM IN-07.02 B01C GROUP ROOM 1 G
4 B02 MEN'S RESTROOM IN-09.03 B02 MEN'S RESTROOM 1 E
5 B02A WOMEN'S RESTROOM IN-09.03 B026 WOMEN'S RESTROOOM 1 E
6 B03 GROUP ROOM IN-07.02 B03 GROUP ROOM 1 G
7 B03A GROUP ROOM IN-07.02 B03 GROUP ROOM 1 G
8 B03B STORAGE IN-04.02 B03B STORAGE 1 B
9 B03C STORAGE IN-04.02 B03C STORAGE 1 B
10 B03D STORAGE IN-03.01 B03D STORAGE 1 A
11 B04 LACTATION ROOM IN-07.02 B05 LACTATION ROOM 1 G
12 101 WOMEN'S WAITING IN-04.02 101 WOMENS WAITING ROOM 1 B
13 102 ELEC IN-03.01 102 1 A
14 103 TOILET IN-09.03 103 1 E
15 104 TOILET IN-09.03 104 1 E
16 105 COLLABORATIVE ROOM IN-04.02 105 COLLABORATIVE ROOM 1 B
17 105A SUPERVISOR IN-04.02 105A SUPERVISOR 1 B
18 106 MENTAL HEALTH CONSULT
OFFICE
IN-07.02 106 OFFICE 1 G
19 107 MENTAL HEALTH EXAM
ROOM
IN-07.02 107 EXAM ROOM 1 G
20 108 MENTAL HEALTH CONSULT
OFFICE
IN-07.02 108 OFFICE 1 G
21 109 MENTAL HEALTH CONSULT
OFFICE
IN-07.02 109 OFFICE 1 G
22 110 MENTAL HEALTH EXAM
ROOM
IN-07.02 110 EXAM ROOM 1 G
23 111 MENTAL HEALTH CONSULT
OFFICE
IN-07.02 111 OFFICE 1 G
24 112 PRIMARY CARE EXAM
ROOM
IN-07.02 112 EXAM ROOM 1 G
25 113 PRIMARY CARE EXAM
ROOM
IN-07.02 113 EXAM ROOM 1 G
26 114 PRIMARY CARE EXAM
ROOM
IN-07.02 114 EXAM ROOM 1 G
27 114A CRASH CART IN-04.02 114A CRASH CART 1 B
28 115 PRIMARY CARE EXAM
ROOM
IN-07.02 115 EXAM ROOM 1 G
29 116 PRIMARY CARE EXAM
ROOM
IN-07.02 116 EXAM ROOM 1 G
30 117 PRIMARY CARE EXAM
ROOM
IN-07.02 117 EXAM ROOM 1 G
31 118 SUPPLY IN-04.02 118 SUPPLY 1 B
32 119 MEDS IN-04.02 119 MEDS 1 B
33 119A STORAGE IN-04.02 119A STORAGE 1 B
34 119B STORAGE IN-04.02 119B STORAGE 1 B
35 120 GROUP ROOM IN-07.02 GROUP ROOM 1 G
36 120A STAIR IN-09.08D 120A STAIR 1 F
37 121 CHECK-IN CLERKS IN-04.02 121 CHECK-IN CLERKS 1 B
37A 121 CHECK-IN CLERKS IN-08.02C DO NOT ENTER 1 C
38 121A CLERK AREA IN-08.02C DO NOT ENTER 1 C
38A 121A CLERK AREA IN-04.02 121A CLERK AREA 1 B
39 122 SUPERVISOR OFFICE IN-04.02 122 OFFICE 1 B
40 123 STAFF ROOM IN-04.02 123 STAFF ROOM 1 B
41 124 TOILET IN-09.03 124 1 E
42 124A HAC IN-04.02 124A 1 B
43 125 TOILET IN-09.03 125 1 E
44 126 PSYCHIATRIC CONSULT
OFFICE
IN-07.02 126 OFFICE 1 G
45 127 STOR/EMS IN-04.02 127 STORAGE 1 B
46 128 PSYCHIATRIC CONSULT
OFFICE
IN-07.02 128 OFFICE 1 G
47 129 PSYCHIATRIC CONSULT
OFFICE
IN-07.02 129 OFFICE 1 G
48 129A STAIR IN-09.08D 129A STAIR 1 F
49 130 PSYCHIATRIC CONSULT
OFFICE
IN-07.02 131 OFFICE 1 G
50 131 PSYCHIATRIC CONSULT
OFFICE
IN-07.02 131 OFFICE 1 G
51 132 TOILET IN-09.03 132 1 E
52 133 TOILET IN-09.03 133 1 E
53 134 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 134 OFFICE 1 G
54 135 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 135 OFFICE 1 G
55 136 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 136 OFFICE 1 G
56 136A STORAGE IN-04.02 136A OFFICE 1 B
57 137 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 137 OFFICE 1 G
58 138 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 138 OFFICE 1 G
59 139 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 139 OFFICE 1 G
60 140 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 140 OFFICE 1 G
61 141 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 141 OFFICE 1 G
62 142 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 142 OFFICE 1 G
63 143 PSYCH/SOCIAL CONSULT
OFFICE
IN-07.02 143 OFFICE 1 G
SEE NOTE A14 ON A103.3 / A103.4
Revisions: Date:
DN
1 2 3 4 5
A
B
C
D.2
E.2
E.8
D
E
F
6.2
C.2 C.1
GROUP ROOM
B01B
GROUP ROOM
B01A
174 SF
WOMEN'S
RESTROOM
B02A
194 SF
GROUP ROOM
B01C
165 SF
MEN'S
RESTROOM
B02
1070 SF
CORRIDOR
B00W
/1 IF100.2
900 SF
WAITING/
BREAKOUT
B01
120 SF
CLERK
B01D
P-1
P-6
P-1
P-6
P-6
P-1
P-1
P-6P-1
P-1 P-6
/1 IF100.2
TS - 1
A513 R 35' - 8 1/4"
R 35' - 8 1/4"
R 35' - 8 1/4"
LVT-2
LVT-1
LVT-3
PT-1
PT-2
QT-1
WP - 4
CT-2
CT-1
X
TS - # FLOOR TRANSITION
TAG
WALL FINISH TYPE - SEE
ROOM FINISH SCHEDULE
FOR ADDITIONAL
INFORMATION
WALL GUARD
WP-2 = SURFACE MOUNTED
WP-6 = END WALL PROTECTOR
SEE ROOM FINISH SCHEDULE
FOR ADDITIONAL INFORMATION
X
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
31 JAN 2020
BASEMENT - FLOOR AND W.P.
FINISH PLAN ZONE 1
RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
PB DM
542-18-106
IF100.1
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
1/4" = 1'-0"
BASEMENT - FLOOR & W.P. PARTIAL FINISH PLAN - ZONE 1
FLOOR AND WALL PROTECTION FINISH LEGEND
0 2' 4' 8'
Revisions: Date:
CRAWL SPACE
/1 IF101.1
900 SF
WAITING/
BREAKOUT
B01
244 SF
GROUP ROOM
B03A
90 SF
LACTATION
ROOM
B04
27 SF
STORAGE
B03D
174 SF
WOMEN'S
RESTROOM
B02A
288 SF
GROUP ROOM
B03
27 SF
ELECTRICAL
CLOSET
B03C
17 SF
STORAGE
B03B
P-6
P-1
P-1
P-1 P-6
P-6
P-1
P-1
P-1
P-1P-6
/1 IF101.1
T S
-1
TS-2
LVT-2
LVT-1
LVT-3
PT-1
PT-2
QT-1
WP - 4
CT-2
CT-1
X
TS - # FLOOR TRANSITION
TAG
WALL FINISH TYPE - SEE
ROOM FINISH SCHEDULE
FOR ADDITIONAL
INFORMATION
WALL GUARD
WP-2 = SURFACE MOUNTED
WP-6 = END WALL PROTECTOR
SEE ROOM FINISH SCHEDULE
FOR ADDITIONAL INFORMATION
X
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
31 JAN 2020
BASEMENT - FLOOR AND W.P.
PARTIAL FINISH PLAN ZONE 2
RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
PB DM
542-18-106
IF100.2
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
1/4" = 1'-0"
BASEMENT - FLOOR & W.P. PARTIAL FINISH PLAN ZONE 2
FLOOR AND WALL PROTECTION FINISH LEGEND
0 2' 4' 8'
Revisions: Date:
LVT-2
LVT-1
LVT-3
PT-1
PT-2
QT-1
WP - 4
CT-2
CT-1
X
TS - # FLOOR TRANSITION
TAG
WALL FINISH TYPE - SEE
ROOM FINISH SCHEDULE
FOR ADDITIONAL
INFORMATION
WALL GUARD
WP-2 = SURFACE MOUNTED
WP-6 = END WALL PROTECTOR
SEE ROOM FINISH SCHEDULE
FOR ADDITIONAL INFORMATION
X
CLEAN SHIP /
REC
B07H OFFICE
B07K
STAIR
WOMENS
B08
STAFF
WOMENS
BATHROOM
B08A ELEVATOR
SERVICE
ROOM
B16A
WORKSHOP
B11
CLEAN STORE
ROOM
B07F
MECHANICAL
ROOM
B07G
STORAGE
B11A
OFFICE
B11B
426 SF
CORRIDOR
B00E
7 8
8 9 10 11 12
E.8
E.8
F.8F.8
HH
II
JJ
F
F
GG
6.8
G.5G.5
A443
CRAWL SPACE
A .4
/1 A100.4FEC
FE
C
FE
C
A .2
/1 A100.3
ELEVATOR
SERVICE
ROOM 2
B16B
P-1
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
31 JAN 2020
BASEMENT - FLOOR AND W.P.
PARTIAL FINISH PLAN ZONE 4
RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
PB DM
542-18-106
IF100.4
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
FLOOR AND WALL PROTECTION FINISH LEGEND
1/4" = 1'-0"
CD 00 - Finish Plan Enlarged - Zone 4
Revisions: Date:
F E
C
FEC
VESTIBULE
TOILET
PSYCH/SOCIAL
CONSULT
OFFICE
SUPERVISOR
OFFICE
PSYCH/SOCIAL
CONSULT
OFFICE
PSYCH/SOCIAL
CONSULT
OFFICE
PSYCH/SOCIAL
CONSULT
OFFICE
PSYCH/SOCIAL
CONSULT
OFFICE
PSYCH/SOCIAL
CONSULT
OFFICE
PSYCH/SOCIAL
CONSULT
OFFICE
PSYCH/SOCIAL
CONSULT
OFFICE
PSYCH/SOCIAL
CONSULT
OFFICE
PSYCH/SOCIAL
CONSULT
OFFICE
IT
ELEC
PSYCHIATRIC
CONSULT
OFFICE
PSYCHIATRIC
EXAM
PSYCHIATRIC
CONSULT
OFFICE
PSYCHIATRIC
EXAM
PSYCHIATRIC
EXAM
CONFERENCE
ROOM
/1 IF101.2
IF
. 3
STORAGE
150AP-6
P-1
P-1 P-1
P-2
P-4
P-4P-2
P-4P-2
P-4P-2
P-4 P-1
P-4 P-1
P-4 P-1
P-4 P-1
P-4 P-1
P-2
P-5
P-2
P-4 P-5 P-5
P-2 P-2 P-6
P-6
P-1
P-2
P-1
P-1
P-2
P-1
T S
P-1
/1 IF101.2
IF
. 3
P-4
P-1
P-4
P-1
P-1
WP-2
WP-2
T S
1' - 3" 1' - 3"1' - 3"
1' - 3" 1' - 3" 1' - 3"
LVT-2
LVT-1
LVT-3
PT-1
PT-2
QT-1
WP - 4
CT-2
CT-1
X
TS - # FLOOR TRANSITION
TAG
WALL FINISH TYPE - SEE
ROOM FINISH SCHEDULE
FOR ADDITIONAL
INFORMATION
WALL GUARD
WP-2 = SURFACE MOUNTED
WP-6 = END WALL PROTECTOR
SEE ROOM FINISH SCHEDULE
FOR ADDITIONAL INFORMATION
X
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phas…
This is the start of the file's text. The full file is on GovTribe.