This document provides details for a federal construction contract opportunity to renovate two floors of an outpatient mental health clinic at a Department of Veterans Affairs medical center. The project involves demolishing and renovating approximately 28,000 square feet of existing space on the first and second floors as well as 3,000 square feet in the basement wing. Scope of work includes general construction, site work, structural work, hazardous material abatement, architectural finishes, fire protection, mechanical, plumbing and electrical systems. The solicitation will be available for download on June 23, 2020 from SAM.gov and bids are due on a date specified in the solicitation. Only verified Service-Disabled Veteran-Owned Small Businesses will be considered for the firm fixed price contract award, which is subject to FY20 funding availability. The period of performance is 588 calendar days from notice to proceed. Interested contractors must have the ability to provide 100% payment and performance bonds and a 20% bid guarantee.
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 GENERAL NOTES
1.1. CODES AND DESIGN CRITERIA
a BUILDING CODE: INTERNATIONAL EXISTING BUILDING CODE b RISK CATEGORY IV
1.2. DESIGN LOADS
a ROOF LOAD
DEAD LOAD 25 PSF
LIVE LOAD 20 PSF
b ATTIC ADJACENT TO AHU
LIVE LOAD 20 PSF
c MECHANICAL EQUIPMENT SEE PLAN d FLOOR LOAD (EXISTING)
DEAD LOAD 80 PSF
LIVE LOAD 75 PSF
e SNOW LOAD GROUND SNOW LOAD Pg 30 PSF IMPORTANCE FACTOR Is 1.1 SNOW EXPOSURE FACTOR Ce 1.0 SNOW THERMAL FACTOR Ct 1.0 FLAT ROOF SNOW LOAD Pf 23 PSF f WIND LOADS (ASCE7-10)
MWFRS
BASIC WIND SPEED 120 mph (3 SEC GUST)
RISK CATEGORY IV
WIND EXPOSURE C
INTERNAL PRESSURE COEFFICIENT +/- .18
COMPONENTS & CLADDING
TRIBUTARY AREA 10 SQUARE FEET
ROOF ZONE 1 +16/-59 PSF
ROOF ZONE 2 +16/-77 PSF
ROOF ZONE 3 +16/-105 PSF
WALLS (TRIBUTARY AREA > 100 SQUARE FEET)
WALL ZONE 4 +28/-34 PSF
WALL ZONE 5 +28/-39 PSF
g SEISMIC LOADS
RISK CATEGORY IV
SEISMIC IMPORTANCE FACTOR 1.5
Ss .193 Sds .206 S1 .048 Sd1 .027
SITE CLASS D
SEISMIC DESIGN CATEGORY C
1.3 GENERAL REQUIREMENTS
a DEFINITIONS
PRIMARY STRUCTURAL SYSTEM IS THE COMPLETED
COMBINATION OF ELEMENTS WHICH SERVE TO
SUPPORT THE BUILDING'S SELF-WEIGHT, THE
APPLICABLE LIVE LOAD, AND THE ENVIRONMENTAL LOADS
SUCH AS WIND, SEISMIC.
PRE-ENGINEERED STRUCTURAL ELEMENTS ARE
STRUCTURAL ELEMENTS WHICH ARE SPECIFIED BY THE
OWNER AS DESIGN DELEGATED ITEMS TO BE THE
DESIGN RESPONSIBILITY OF A SPECIALTY STRUCTURAL
ENGINEER (SSE)
SPECIAL INSPECTION IS INSPECTION PERFORMED BY A
QUALIFIED PERSON, APPROVED BY THE BUILDING
OFFICIAL, FOR THE TYPES OF WORK REQUIRING
INSPECTION PER THE GOVERNING CODES AND
CONTRACT DOCUMENTS.
SPECIALTY STRUCTURAL ENGINEER (SSE) IS A
LICENSED PROFESSIONAL/STRUCTURAL ENGINEER, NOT
THE SER, WHO IS RESPONSIBLE FOR SEALING PLANS AND
DESIGNS FOR PRE-ENGINEERED STRUCTURAL ELEMENTS
WHICH ARE NECESSARY FOR THE STRUCTURE TO BE
COMPLETED AND THE OWNER HAS DESIGNATED AS DESIGN
DELEGATED ITEMS.
STRUCTURAL ENGINEER OF RECORD (SER) IS THE
STRUCTURAL ENGINEER WHO IS LEGALLY ELIGIBLE TO SEAL
THE STRUCTURAL DOCUMENTS FOR A BUILDING PROJECT.
THE SER IS RESPONSIBLE FOR THE DESIGN OF THE PRIMARY
STRUCTURAL SYSTEM.
DESIGNATED REPRESENTATIVE FOR CONSTRUCTION (COR
- I.E., COR) IS RESPONSIBLE FOR THE OVERALL
CONSTRUCTION OF THE PROJECT INCLUDING PROJECT
SCHEDULING, JOB SITE SAFETY AND MEANS AND
METHODS OF CONSTRUCTION.
SPECIAL INSPECTOR: A QUALIFIED PERSON EMPLOYED
OR RETAINED BY AN APPROVED AGENCY AND
APPROVED BY THE BUILDING OFFICIAL AS HAVING THE
COMPETENCE NECESSARY TO INSPECT A PARTICULAR TYPE
OF CONSTRUCTION REQUIRING SPECIAL INSPECTION.
b THE STRUCTURAL DRAWINGS ARE TO BE USED IN
CONJUNCTION WITH THE SPECIFICATIONS AND THE
GEOTECHNICAL REPORT.
c THE COR SHALL COORDINATE WITH THE MECHANICAL
AND ARCHITECTURAL DRAWINGS AND WITH THE
MECHANICAL CONTRACTOR, THE LOCATION OF ALL
MECHANICAL EQUIPMENT.
d THE COR SHALL NOTIFY THE ARCHITECT IF THE
WEIGHTS OF MECHANICAL UNITS ETC. ARE DIFFERENT FROM
THE WEIGHTS POSTED ON THE DESIGN DRAWINGS.
DISCREPANCIES SHALL BE RESOLVED BEFORE
PROCEEDING WITH CONSTRUCTION.
e THE COR SHALL NOTIFY THE ARCHITECT/ENGINEER
IMMEDIATELY OF ANY DISCREPANCIES TO AVOID THE
POSSIBILITY OF UNNECESSARY FUTURE PROBLEMS AND
POSSIBLE FIELD ORDERS. FAILURE TO DO SO WILL PUT THE
FULL RESPONSIBILITY OF CORRECTION ON THE COR.
f THE COR SHALL COORDINATE THE WORK OF ALL
TRADES AND MAKE NECESSARY INVESTIGATIONS AND
FIELD MEASUREMENTS.
g DO NOT SCALE DRAWINGS.
h THE SER HAS NO SUPERVISORY RESPONSIBILITY, HAS
NO CONTROL OF OR RESPONSIBILITY FOR THE MEANS,
METHODS, TECHNIQUES, PROCEDURES OR SEQUENCE OF
CONSTRUCTION, HAS NO RESPONSIBILITY FOR THE FAILURE
OF ANY CONTRACTOR TO PERFORM THE WORK IN
ACCORDANCE WITH THE DESIGN DOCUMENTS AND NO
RESPONSIBILITY TO DEVISE, IMPLEMENT OR ENFORCE ANY
SAFETY PRECAUTIONS OR PROGRAMS FOR THE PROJECT
1.4 SLEEVES, ANCHORAGES, OPENINGS, ETC.
a IN GENERAL, STRUCTURAL DRAWINGS DO NOT SHOW
EQUIPMENT PADS, DRAINS, HOLES, ANCHORAGES,
INSERTS AND SLEEVES FOR ITEMS PASSING THROUGH OR
ATTACHED TO CONCRETE OR FRAMING. REFER TO
ARCHITECTURAL, MECHANICAL, AND ELECTRICAL
DRAWINGS AND PROJECT SPECIFICATIONS. ADJUST
EQUIPMENT PADS AND SUB FRAMING TO FIT
EQUIPMENT FURNISHED.
b PROVIDE SUB FRAMING FOR EQUIPMENT SUPPORTED
ON OR SUSPENDED FROM THE STRUCTURE.
1.5 STRUCTURAL STABILITY AND CONSTRUCTION
a INDIVIDUAL STRUCTURAL COMPONENTS ARE DESIGNED
TO SUPPORT LOADS IN THEIR FINAL ERECTED POSITION AS PART
OF THE TOTAL COMPLETED STRUCTURE.
b COR TO PROVIDE TEMPORARY GUYING AND BRACING
AS REQUIRED UNTIL ALL CONSTRUCTION AFFECTING
LATERAL STABILITY IS COMPLETED.
c COR SHALL BE SOLELY RESPONSIBLE FOR STABILITY OF
STRUCTURE, ITS PARTS BY USE OF GUYING, BRACING, SHORING,
BARRICADES, SAFETY RAILINGS AND DEVICES DURING THE
ENTIRE PERIOD OF CONSTRUCTION.
d COR SHALL BE SOLELY RESPONSIBLE FOR ALL JOB
SITE SAFETY AND MEANS AND METHOD OF
CONSTRUCTION.
1.6 SHOP DRAWINGS AND TEST REPORTS
a COR SHALL CHECK ALL SHOP DRAWINGS BEFORE
SUBMITTAL TO SER FOR REVIEW.
b COR SHALL PREPARE A SHOP DRAWING SUBMITTAL
SCHEDULE WITH A MINIMUM OF TWO WEEKS INCLUDED FOR THE
SER'S REVIEW OF EACH SUBMITTAL LISTED BELOW.
c REVIEW BY SER WILL BE FOR CONFORMANCE TO
GENERAL LAYOUT AND DESIGN INTENT ONLY.
d CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR
ACCURACY OF DIMENSIONS, FABRICATION, FIT UP OF PARTS AND
BILLS OF MATERIALS.
e CONTRACTOR SHALL COORDINATE WORK OF VARIOUS
TRADES AND MAKE NECESSARY FIELD MEASUREMENTS.
f THE CONTRACT SPECIFICATIONS PROVIDE A COMPLETE
LISTING OF SUBMITTALS. THE FOLLOWING IS A
SUMMARY OF THE REQUIRED SUBMITTALS:
CONCRETE
CONCRETE MIX DESIGNS WITH ASSOCIATED
HISTORICAL TEST DATA
REINFORCING STEEL PLACEMENT DRAWINGS PER
ACI 315
CONCRETE MASONRY
PRODUCT DATA SHEETS
REINFORCING STEEL PLACEMENT DRAWINGS
STRUCTURAL STEEL
STRUCTURAL STEEL SHOP DRAWINGS
CONNECTION DESIGN SIGNED AND SEALED BY
LICENSED SSE.
METAL DECK (ROOF)
SHOP DRAWINGS
MISCELLANEOUS METALS (STAIRS/HANDRAIL/GUARD
RAIL/LADDERS ETC.)
STRUCTURAL STEEL SHOP DRAWINGS
DESIGN CALCULATIONS SIGNED AND SEALED BY
LICENSED SSE.
UNDERPINNING/SHORING PROCEDURES AND SEALED
CALCULATIONS
1.7 DEFERRED SUBMITTALS - OWNER SPECIFIED DESIGN DELEGATED
COMPONENTS
a CERTAIN COMPONENTS OF THE COMPLETED
CONSTRUCTION ARE DESIGN DELEGATED TO THE
MANUFACTURER OF THE COMPONENT. THE
MANUFACTURER'S SSE SHALL BE RESPONSIBLE FOR THE DESIGN
OF THE COMPONENT. THE FOLLOWING ARE DESIGNATED TO BE
DESIGN DELEGATED COMPONENTS ON THIS PROJECT:
b STRUCTURAL STEEL CONNECTIONS c MISCELLANEOUS METALS (STAIRS, GUARDRAIL, HANDRAIL, LADDERS, ETC.)
d TEMPORARY SHORING AND BRACING e UNDERPINNING FOUNDATIONS f TEMPORARY EARTH RETENTION SYSTEMS g OTHER WORK AS LISTED ON DRAWINGS, SPECIFICATIONS AND CUSTOMARY INDUSTRY
STANDARDS. WHERE DELEGATION OF DESIGN IS
SPECIFIED,
h THE MANUFACTURER SHALL BE RESPONSIBLE FOR
RETAINING THE SERVICES OF A LICENSED SPECIALTY
STRUCTURAL ENGINEER (SSE) IN THE STATE HAVING
JURISDICTION. THE SSE SHALL DESIGN AND DETAIL
COMPONENTS TO MEET GOVERNING BUILDING CODES,
STANDARDS AND THE SPECIFIED PERFORMANCE
CRITERIA. SIGNED AND SEALED CALCULATIONS SHALL BE
SUBMITTED FOR RECORD. THE DESIGN DELEGATED SSE
SHALL BE SOLELY RESPONSIBLE FOR THE DESIGN OF THE
COMPONENT.
i SSE SUBMITTALS WILL BE REVIEWED BY THE SER FOR
LOADING CRITERIA AND GENERAL CONFORMANCE TO
THE PRIMARY STRUCTURAL SYSTEM.
1.8 DEMOLITION
a THE ARCHITECTURAL/STRUCTURAL DEMOLITION
DRAWINGS INDICATE THE GENERAL AREAS OF
DEMOLITION. THE COR SHALL VERIFY IN THE FIELD ALL
ITEMS TO BE REMOVED TO MEET THE REQUIREMENTS OF
THE CONTRACT DOCUMENTS.
b THE COR SHALL CAREFULLY REMOVE ONLY THE
EXISTING ITEMS IDENTIFIED ON THE ARCHITECTURAL AND
STRUCTURAL DRAWINGS.
c IN NO CASE SHALL THE REMOVAL OF ANY PORTION
OF THE EXISTING STRUCTURE BE PERFORMED IN SUCH A
WAY AS TO AFFECT THE STRUCTURAL INTEGRITY OF THE
REMAINING PORTION OF THE BUILDING.
d THE CONTRACTOR SHALL NOTIFY THE SER IMMEDIATELY
OF ANY STRUCTURAL ITEMS WHICH NEED TO BE
DEMOLISHED BUT ARE NOT CLEARLY IDENTIFIED ON THE
STRUCTURAL OR ARCHITECTURAL DRAWINGS.
e THE CONTRACTOR SHALL MINIMIZE THE EXTENT OF
THE DEMOLITION TO THE EXISTING STRUCTURE TO
ONLY THAT REQUIRED TO INSTALL THE NEW BUILDING
MODIFICATIONS.
2 FOUNDATIONS
2.1 GENERAL
a THE FOUNDATION DESIGN IS BASED ON THE
GEOTECHNICAL REPORT PREPARED BY (LATER) AND
DATED (LATER). REFER TO GEOTECHNICAL REPORT FOR
ADDITIONAL GEOTECHNICAL REQUIREMENTS.
b SUMMARY OF GEOTECHNICAL DESIGN VALUES
SHALLOW STRIP AND SPREAD FOOTINGS
ALLOWABLE SOIL BEARING PRESSURE 3,000 PSF
DEPTH OF FOOTING BELOW FINISHED GRADE 42”.
BASEMENT (RESTRAINED), RETAINING WALLS
(UNRESTRAINED) WALLS
BACKFILL - GRANULAR
DENSITY - 115 PCF
ACTIVE LATERAL PRESSURE (UN RESTRAINED) - 45 PSF/FT
AT REST LATERAL PRESSURE (RESTRAINED) - 65 PSF/FT
SURCHARGE COEFFICIENT (UN-RESTRAINED) - .3 X
LOAD(PSF) - PSF
SURCHARGE COEFFICIENT (RESTRAINED) - .5 X LOAD (PSF)
- PSF
COEFFICIENT OF SLIDING RESISTANCE - .4
c CONTRACTOR SHALL LOCATE ALL EXISTING BELOW GRADE
UTILITIES AND INTERFERENCES PRIOR TO START OF
WORK. NOTIFY THE SER OF ANY INTERFERENCE.
d REFER TO CIVIL DRAWINGS FOR ALL SOIL IMPROVEMENT, SITE PREPARATION, GRADING, EROSION PROTECTION AND
SITE UTILITY WORK.
e STRIP TOPSOIL OVER THE ENTIRE BUILDING AREA.
f PROTECT ALL EXPOSED SURFACES IN ACCORDANCE WITH
THE GEOTECHNICAL REPORT.
g MAINTAIN ALL EXCAVATIONS FREE OF WATER
CONTINUOUSLY
h COR SHALL BE RESPONSIBLE FOR ALL SHORING/BRACING
OF EXCAVATIONS.
i ALL SHALLOW FOUNDATIONS SHALL BE LOCATED SHALL
BEAR AT SUFFICIENT DEPTH TO PROVIDE ADEQUATE
FROST COVERAGE PER LOCAL REQUIREMENTS.
j A GEOTECHNICAL TESTING SERVICE SHALL CONFIRM ALL
SOIL BEARING CAPACITIES PRIOR TO PLACEMENT OF
CONCRETE FOUNDATIONS.
k DO NOT BACKFILL BEHIND BASEMENT WALLS UNTIL ALL
FRAMING IS COMPLETED UNLESS TEMPORARY
BRACING/SHORING IS PROVIDED BY THE COR'S SSE.
l ALL STRUCTURAL FILL AND GENERAL FILL SHALL MEET THE
REQUIREMENTS OF THE GEOTECHNICAL REPORT
INCLUDING MATERIAL SPECIFICATION AND COMPACTION
REQUIREMENTS.
m ALL BASEMENT AND RETAINING WALLS ARE DESIGNED
CONSIDERING A GRANULAR BACKFILL MATERIAL.
2.2 SHORING AND UNDERPINNING FOUNDATIONS
a SHORING AND UNDERPINNING ARE DESIGNATED AS A
DELEGATED DESIGN ITEMS AND SHALL BE DESIGNED BY
THE COR'S GEOTECHNICAL ENGINEER AND LICENSED
PROFESSIONAL ENGINEER.
b ALL SHORING OF EXISTING FOUNDATIONS REQUIRED BY
THE COR DUE TO EXCAVATIONS NEAR EXISTING
STRUCTURES AND UNDERPINNING OF EXISTING
FOUNDATIONS AS INDICATED ON THE DESIGN DRAWINGS
IS A DELEGATED DESIGN ITEM AND SHALL BE DESIGNED BY
THE COR'S GEOTECHNICAL AND LICENSED STRUCTURAL
ENGINEERS.
c ANY UNDERPINNING PROCEDURES INDICATED ON THE
DESIGN DRAWINGS ARE CONCEPTUAL ONLY AND SHALL BE
CONFIRMED BY THE COR'S GEOTECHNICAL AND
STRUCTURAL ENGINEERS.
d SUBMIT SHORING AND UNDERPINNING PROCEDURES AND
SEALED CALCULATIONS TO THE ARCHITECT FOR RECORD
PURPOSES ONLY.
3 CONCRETE CONSTRUCTION
3.1 CAST IN PLACE CONCRETE
a GENERAL REQUIREMENTS
ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI 301-10,
SPECIFICATION FOR STRUCTURAL CONCRETE, EXCEPT AS
MODIFIED BY THE REQUIREMENTS OF THE CONTRACT
DOCUMENTS.
SUBMITTALS
CONCRETE MIXES WITH HISTORICAL TEST DATA.
MATERIAL CERTIFICATES: CEMENT, AGGREGATES, ADMIXTURES,
REINFORCING STEEL
REINFORCING STEEL PLACEMENT DRAWINGS
b PRODUCTS
REINFORCING BARS: ASTM A615 GRADE 60
REINFORCING BARS WELDABLE: ASTM A706 GRADE 60
PLAIN WIRE FABRIC: ASTM A185
AGGREGATES: ASTM C33
WATER: POTABLE ASTM C94
ADMIXTURES
AIR ENTRAINING ASTM C260
CHEMICAL ADMIXTURES ASTM C 494
AIR CONTENT FOR CONCRETE EXPOSED TO WEATHER: 4 TO 7%.
SLUMP: 4"
CONCRETE STRENGTH: F'C 4,000 PSI AT 28 DAYS
MIXING PER ASTM C94
CURING COMPOUNDS: ASTM C309 OR C1315
c EXECUTION
CONCRETE COVER
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO
EARTH 3"
CONCRETE EXPOSED TO EARTH OR WEATHER 2"
CONCRETE NOT EXPOSED TO WEATHER 1-1/2"
ALL FOOTINGS, WALL FOOTINGS, GRADE BEAMS AND PILE/CAISSON
CAPS SHALL BE FORMED UNLESS NOTED.
LAP SPLICE LENGTHS PER ACI 318 CHAPTERS 12 USING A CLASS B
SPLICE. ALL WELDED WIRE FABRIC SHALL BE LAPPED ONE GRID
MINIMUM
LOCATE JOINTS AS SHOWN ON PLANS; WHERE NOT SHOWN,
CONTROL OR CONSTRUCTION JOINTS SHALL BE PLACED IN
ACCORDANCE WITH ACI RECOMMENDATIONS I.E., A MAXIMUM
PANEL SIZE (IN FEET) EQUAL TO APPROXIMATELY THREE TIMES
THE THICKNESS OF THE SLAB (IN INCHES) IN BOTH DIRECTIONS.
HOOK ENDS OF BARS INTERRUPTED BY OPENINGS.
HOOK TOP BARS AT ALL CONCRETE EDGES, AT ALL WALL AND
SLAB OPENINGS,
PROVIDE 2-#5 BARS X OPENING WIDTH PLUS 4 FEET (2 FEET EACH
SIDE) EACH FACE, UNLESS SHOWN OTHERWISE.
PLACEMENT OF CONCRETE IN COLD WEATHER SHALL COMPLY
WITH ACI306
PLACEMENT OF CONCRETE IN HOT WEATHER SHALL COMPLY WITH
ACI305
TOLERANCES SHALL MEET ACI 117, ACI 301 AND ACI 318 AS A
MINIMUM.
SOILS (IBC 2018 TABLE 1705.6)
1 VERIFY BEARING CAPACITY BELOW SHALLOW FOUNDATIONS (P)
2 VERIFY EXCAVATIONS EXTEND TO PROPER DEPTH AND REACHED PROPER
MATERIAL (P).
3 PERFORM CLASSIFICATION AND TESTING OF COMPACTED MATERIAL (P)
4 VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING
PLACEMENT AND COMPACTION OF COMPACTED MATERIAL (C).
5 PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE AND VERIFY
THAT SITE HAS BEEN PROPERLY PREPARED (P)
6 VERIFY SOIL IMPROVEMENT HAS BEEN PERFORMED PROPERLY (P)
1.9 STRUCTURAL TESTS AND INSPECTIONS (IBC 2018)
a AN INDEPENDENT APPROVED AGENCY SHALL PROVIDE SPECIAL INSPECTIONS
AND TESTS DURING CONSTRUCTION IN ACCORDANCE WITH CHAPTER 17 OF
IBC 2018.
b THE APPROVED AGENCY'S SPECIAL INSPECTOR SHALL OBSERVE THE WORK
ASSIGNED FOR CONFORMANCE TO THE APPROVED DESIGN DRAWINGS AND
SPECIFICATIONS.
c THE APPROVED AGENCY SHALL KEEP RECORDS OF ALL SPECIAL INSPECTIONS
AND TESTS AND SUBMIT REPORTS TO THE BUILDING OFFICIAL AND THE SER.
d ALL DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF
THE COR FOR CORRECTION. IF UNCORRECTED, THE APPROVED AGENCY SHALL
NOTIFY THE BUILDING OFFICIAL AND THE SER.
e REFER TO IBC 2018 1704.5 FOR SUBMITTALS TO THE BUILDING OFFICIAL IN
ADDITION TO THE REPORTS.
f THE APPROVED AGENCY SHALL SUBMIT A FINAL REPORT STATING WHETHER THE
WORK REQUIRING SPECIAL INSPECTION WAS IN CONFORMANCE WITH THE
APPROVED CONTRACT DOCUMENTS AND THE APPLICABLE WORKMANSHIP
PROVISIONS OF THIS CODE.
g QUALITY CONTROL SHALL BE THE RESPONSIBILITY OF THE
FABRICATOR/ERECTOR IN ACCORDANCE WITH AISC360-10 CHAPTER N.
h JOB SITE VISITS BY THE SER DO NOT CONSTITUTE AN OFFICIAL SPECIAL
INSPECTION.
STATEMENT OF SPECIAL INSPECTIONS:
a REFER TO THE REFERENCED DOCUMENTS (IBC 2018 CHAPTER 17, AISC 360-14
CHAPTER N, ACI530-13 CHAPTER 3, ) FOR ADDITIONAL DESCRIPTIONS OF
REQUIREMENTS.
b STRUCTURAL OBSERVATIONS FOR SEISMIC NOT REQUIRED: SDC-C c STRUCTURAL OBSERVATIONS FOR WIND NOT REQUIRED VASD = 93 mph d THE FOLLOWING LIST OF MATERIALS AND WORK REQUIRE SPECIAL INSPECTIONS
(P) PERIODIC; (C) CONTINUOUS
STRUCTURAL STEEL (1705.2 - AISC360-14 CHAPTER N)
1 INSPECTION TASKS PRIOR TO WELDING SHOP/FIELD (AISC360-10 TABLE N5.4-1 &
AWS D1.1)
a REVIEW WELDING PROCEDURE SPECIFICATIONS (WPS) & WELDING CONSUMABLES
(C) b FIT UP GROOVE AND FILLET WELDS (P) c CONFIGURATION OF ACCESS HOLES (P)
2 INSPECTION TASKS DURING WELDING SHOP/FIELD (AISC360-10 TABLE N5.4-2 & AWS
D1.1) a QUALIFIED WELDERS (C) b CONTROL AND HANDLING OF CONSUMABLES (C) c NO WELDING OVER TACK WELDS (C) d ENVIRONMENTAL CONDITIONS (C) e WPS FOLLOWED (C) f WELDING TECHNIQUES (C)
3 INSPECTION TASKS AFTER WELDING SHOP/FIELD (AISC360-10 TABLE N5.4-3 & AWS
D1.1) a WELDS CLEANED (C) b SIZE, LENGTH, LOCATION OF WELDS (C) c WELDS MEET VISUAL ACCEPTANCE CRITERIA (C) d CJP GROOVE WELD NDT PER AWS D1.1 (C)
4 INSPECTION TASKS PRIOR TO BOLTING (AISC360-10 TABLE N5.6-1)
a BOLT MATERIAL GRADE b PROPER FASTENERS USED PER CONTRACT DOCUMENTS (P) c PROPER BOLTING PROCEDURE SELECTED FOR JOINT DETAIL (P) d CONNECTION ELEMENTS INCLUDING FAYING SURFACES MEET REQUIREMENTS (P) e PROPER STORAGE OF FASTENER COMPONENTS (P)
5 INSPECTION TASKS DURING BOLTING (AISC360-10 TABLE N5..6-2)
a FASTENER ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALL HOLES AND
POSITIONED AS REQUIRED (P).
b JOINT BROUGHT TO SNUG TIGHT CONDITION (P) c FASTENER COMPONENT NOT TURNED BY WRENCH PREVENTED FROM ROTATING
(P) d FASTENERS PRETENSIONED PER RCSC SPECIFICATION (P)
6 INSPECTION TASKS AFTER BOLTING (AISC360-10 TABLE N5.6-3)
a DOCUMENT ACCEPTED OR REJECTED BOLTED CONNECTIONS (C)
7 INSPECTION OF ANCHOR RODS IN CONFORMANCE WITH CONTRACT DOCUMENTS.
(P)
8 INSPECTION OF STEEL FRAME/CONNECTION DETAILS IN CONFORMANCE WITH
CONTRACT DOCUMENTS. (P)
MASONRY CONSTRUCTION (ACI530-13 LEVEL B QUALITY ASSURANCE TABLE 3.1.2)
1 VERIFY COMPLIANCE WITH APPROVED SUBMITTALS (P)
2 AS MASONRY CONSTRUCTION BEGINS, VERIFY COMPLIANCE OF THE FOLLOWING:
a PROPORTIONS OF SITE-PREPARED MORTAR (P) b CONSTRUCTION OF MORTAR JOINTS (P) c GRADE AND SIZE OF REBAR (P) d LOCATION OF REINFORCEMENT AND CONNECTORS 9P)
3 PRIOR TO GROUTING, VERIFY COMPLIANCE OF FOLLOWING:
a GROUT SPACE b GRADE, TYPE AND SIZE OF REINFORCEMENT AND ANCHOR BOLTS (P) c PLACEMENT OF REINFORCEMENT AND CONNECTORS (P) d PROPORTIONS OF SITE PREPARED GROUT e CONSTRUCTION OF MORTAR JOINTS (P)
4 VERIFY DURING CONSTRUCTION:
a SIZE AND LOCATION OF STRUCTURAL ELEMENTS (P) b TYPE, SIZE AND LOCATION OF ANCHORS INCLUDING OTHER DETAILS OF ANCHORAGE
TO MASONRY (P)
c WELDING OF REINFORCEMENT (C).
d PREPARTION, CONSTRUCTION AND PROTECTION OF MASONRY DURING COLD/HOT
WEATHER (P)
e PLACEMENT OF GROUT (C)
5 OBSERVE PREPARATION OF GROUT SPECIMENS, MORTAR SPECIMENS AND/OR PRISMS.
(P)
6 MINIMUM TESTS
a VERIFY SLUMP FLOW AND VISUAL STABILITY INDEX.
b VERIFICATION OF f`m PRIOR TO CONSTRUCTION
CONCRETE CONSTRUCTION (IBC 2018 TABLE 1705.3)
1 REINFORCEMENT PLACEMENT (P)
2 REINFORCING BAR WELDING (P)
3 ANCHORS CAST IN CONCRETE (P)
4 POST INSTALLED ANCHORS
a ADHESIVE (C) b MECHANICAL (P)
5 VERIFY USE OF REQUIRED MIX (P)
6 STRENGTH, SLUMP, AIR, TEMPERATURE TEST OF CONCRETE PRIOR TO
PLACEMENT (C)
7 CONCRETE PLACEMENT (C)
8 VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES (P)
9 INSPECT ERECTION OF PRECAST MEMBERS INCLUDING CONNECTIONS (P)
10 INSPECT FORMWORK (P)
RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
542-18-106
Revisions: Date:
FINAL CONCEPT DOCUMENTS SUBMISSION 15 JAN 2019
50% CONSTRUCTION DOCUMENTS SUBMISSION 16 APR 2019
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. 18-102
MOD - 50% CONSTRUCTION DOCUMENTS SUBMISSION 21 JUN 2019
100% CONSTRUCTION DOCUMENTS SUBMISSION 3 JAN 2020
T: F:
www.bancroft-ae.com www.bancroft-ae.com
30 JAN 2020
FINAL CONSTRUCTION DOCUMENTS SUBMISSION 31 JAN 2020
31 JAN 2020
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
STRUCTURAL
GENERAL NOTES
S001
MW PW
AutoCAD SHX Text
NTS
AutoCAD SHX Text
STRUCTURAL GENERAL NOTES
AutoCAD SHX Text S001
AutoCAD SHX Text d MAXIMUM LIVE LOAD DEFLECTION L/360; TOTAL LOAD L/240.
e JOISTS SHALL BE REINFORCED WHERE CONCENTRATED
LOADS ARE PLACED BETWEEN PANEL POINTS IN
ACCORDANCE WITH THE JOIST MANUFACTURER'S
RECOMMENDATIONS.
f JOISTS SHALL BE PRIMED PAINTED WITH MANUFACTURER'S
STANDARD PRIMER UNLESS NOTED OTHERWISE IN THE
PROJECT SPECIFICATION.
5.2 METAL ROOF DECK (MRD)
a METAL ROOF DECK SHALL CONFORM TO STEEL DECK
INSTITUTE SPECIFICATIONS. METAL ROOF DECK TO BE WIDE
RIB 1-1/2" -22 GAGE STEEL DECK, UNLESS NOTED, WITH
NESTING SIDE LAPS LAID 3 SPANS MINIMUM CONTINUOUS.
DECK TO BE GALVANIZED.
b UNLESS NOTED, WELD DECK TO SUPPORT MEMBERS WITH
5/8" PUDDLE WELDS IN A 36/5 PATTERN. PLACE 5/8" DIAMETER
PUDDLE WELDS 6" ON CENTER AT ALL EDGES OF DECK
ADJACENT TO WALLS AND OPENINGS.
c FASTEN SIDE LAPS AT 2'-0" MAXIMUM SPACING WITH #10 HEX
WASHER HEAD SELF-DRILLING SCREWS. WELD WASHERS
SHALL BE USED FOR ALL MATERIAL THICKNESSES LESS THAN
.028.
d DO NOT SUSPEND ANYTHING FROM METAL ROOF DECK.
e COAT WELDS AND ABRADED AREAS WITH ZINC RICH
GALVANIZING PRIME PAINT.
f DECK MANUFACTURER SHALL PROVIDE REINFORCING FOR
ALL OPENINGS UP TO 18"X18". ALL OPENINGS SHALL BE
REINFORCED WITH L4X4X3/8 FRAMES SPANNING BETWEEN
SUPPORT MEMBERS.
5.3 MISCELLANEOUS METALS
a ALL MISCELLANEOUS METALS WORK (GRATING, STAIR
TREADS, SAFETY PLATE, STAIR STRINGERS, LADDERS AND
GUARDRAILS/HANDRAILS) ARE DESIGNATED AS DELEGATED
DESIGN ITEMS TO BE DESIGNED BY THE COR'S SSE.
b MISCELLANEOUS METALS SHALL MEET THE DESIGN
REQUIREMENTS OF THE BUILDING CODE NOTED ABOVE AND
OSHA AND ASCE 7 SECTION 4.4.
c FLOOR GRATING SHALL BE SERRATED GALVANIZED WELDED
GRATING (19W4) WITH 1-1/4" DEEP X 3/16" BEARING BARS
SPACED 1-3/16" ON CENTER AND CROSS BARS SPACED 4" ON
CENTER.
d STAIR TREADS SHALL HAVE THE SAME PATTERN AS THE
GRATING AND HAVE AN ABRASIVE NOSING ON THE FRONT
EDGE. GRATING SHALL CONFORM TO ANSI-NAAM MBG531.
e STANDARD GALVANIZED GRATING CLIPS SHALL BE USED TO
ATTACH GRATING TO THE SUPPORT STEEL. ALL EDGES SHALL
BE BANDED. ALL OPENINGS AROUND PENETRATIONS
EXCEEDING 1-1/2" DIAMETER SHALL BE PROTECTED BY 4" TOE
PLATES. OPENINGS GREATER THAN 8" DIAMETER SHALL BE
PROTECTED BY TOE PLATES AND HANDRAIL.
f CHECKERED SAFETY PLATE: GALVANIZED ASTM A36 SAFETY
PLATE. 1/4" THICK EXCLUSIVE OF HEIGHT OF RAISED PATTERN.
g GUARDRAIL/HANDRAIL SHALL BE DESIGNED TO MEET CODES
LISTED ABOVE. POSTS AND RAILS SHALL BE A MINIMUM 1-1/2"
DIAMETER STANDARD GALVANIZED PIPE (ASTM A53 GR B)
WITH ALL WELDED JOINTS AND FIELDED BOLTED TO
STRINGERS. POSTS SHALL BE SPACED NO GREATER THAN
4'-0" ON CENTER. SHOP FABRICATE IN AS LARGE OF
SECTIONS AS POSSIBLE FOR EASE OF ERECTION. ALL EDGES
SHALL BE ROUNDED AND WELDS GROUND SMOOTH.
h GUARDRAIL AND HANDRAIL SHALL NOT BE USED AS LIFE LINE
TIE OFFS.
i SWING GATES AND CHAINS SHALL CONFORM TO ALL
APPLICABLE CODES.
j LADDERS AND SAFETY CAGES (AS REQUIRED) ASTM A36 -
GALVANIZED
5 METALS
5.1 STRUCTURAL STEEL
a GENERAL
ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE
AISC 360-10 "SPECIFICATIONS FOR STRUCTURAL STEEL
BUILDINGS", "SPECIFICATION FOR STRUCTURAL JOINTS
USING ASTM A325 OR A490 BOLTS" 2009, "CODE OF
STANDARD PRACTICE FOR STEEL BUILDINGS AND
BRIDGES," 2010 AND AWS D1.1 2010.
THE PROVISIONS OF THE ALLOWABLE STRENGTH DESIGN
METHOD (ASD) WAS USED AS A BASIS FOR DESIGN. ALL
FORCES/REACTIONS INDICATED ON THE DESIGN
DOCUMENTS ARE THEREFORE NON-FACTORED ASD
FORCES/REACTIONS.
THE CONTRACTOR'S STRUCTURAL STEEL DETAILER SHALL
PREPARE STEEL ERECTION AND SHOP DRAWINGS IN
ACCORDANCE WITH THE GUIDELINES AND GOOD
PRACTICES NOTED IN THE AISC “DETAILING FOR STEEL
CONSTRUCTION.” THIRD EDITION
STEEL CONNECTIONS ARE DESIGNATED AS A DESIGN
DELEGATED COMPONENT TO BE DESIGNED BY THE COR'S
SSE.
SUBMITTALS
CHECKED STEEL SHOP DRAWINGS: PREPARED IN
ACCORDANCE WITH AISC DETAILING FOR STEEL
CONSTRUCTION 3RD ED.
CONNECTION CALCULATIONS PREPARED, SIGNED AND
SEALED BY COR'S SSE.
MATERIAL CERTIFICATES (UPON REQUEST)
WELDING CERTIFICATES (UPON REQUEST)
b MATERIALS
ALL STRUCTURAL STEEL SHAPES SHALL BE ASTM A992
(Fy=50 ksi)
ALL STRUCTURAL STEEL PLATES AND ANGLES SHALL BE
ASTM A36 (Fy=36 KSI).
ALL STRUCTURAL TUBES SHALL BE ASTM A500 GRADE B
(Fy=46 KSI).
ALL STRUCTURAL PIPES SHALL BE ASTM A53 GRADE B
(Fy=35 KSI).
ALL ANCHOR RODS ASTM F1554-36
ALL WELDING SHALL CONFORM TO AMERICAN WELDING
SOCIETY "STRUCTURAL WELDING CODE", AWS D1.1.
ALL WELD ELECTRODES SHALL BE E70XX AND ALL
WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS.
ALL WELDING SHALL BE TO CLEAN BARE STEEL.
PROVIDE FULL SIZE 1/4" SETTING PLATES ON 4,000 PSI
NON-SHRINK GROUT FOR ALL COLUMNS AND (4)-3/4"
DIAMETER ASTM F-1554-36 ANCHOR BOLTS, UNLESS
NOTED.
ERECT ALL MEMBERS WITH NATURAL CAMBER UP, EXCEPT
FOR CERTAIN CANTILEVERED MEMBERS.
PROVIDE SUB-FRAMING FOR EQUIPMENT SUPPORTED ON
OR SUSPENDED FROM THE STRUCTURE.
ALL STEEL SHALL BE SHOP COATED WITH FABRICATOR'S
STANDARD PRIME PAINT MEETING MPI#79 AS A MINIMUM.
MASK SURFACES TO BE FIELD WELDED AND AT BOLT
HOLES IN FAYING SURFACES OF SLIP CRITICAL BOLTED
CONNECTIONS.
CONNECTIONS
CONNECTIONS SHOWN ON THE DESIGN DRAWINGS ARE
CONCEPTUAL ONLY.
CONNECTIONS ARE A DELEGATED DESIGN ITEM TO BE
DESIGNED BY COR'S SSE.
CONNECTIONS SHALL BE IN ACCORDANCE WITH AISC
360-10 USING ALLOWABLE STRENGTH (ASD) DESIGN BASIS.
POSTED CONNECTION FORCES ARE ASD.
DESIGN SHEAR CONNECTIONS FOR THE LARGER OF
POSTED FORCES ON THE DESIGN DRAWINGS AND 50%
(75% FOR COMPOSITE BEAMS) OF THE MAXIMUM TOTAL
LOAD FOR THE SPECIFIED BEAM AND SPAN IN AISC “STEEL
CONSTRUCTION MANUAL” TABLE 3-6.
DESIGN MOMENT CONNECTIONS FOR FULL MOMENT
CAPACITY OF THE MEMBER OR THE POSTED MOMENT
ALONG WITH THE SHEAR LOADS NOTED ABOVE.
AXIALLY LOADED MEMBERS SHALL BE DESIGNED USING
THE POSTED LOADS AND THE AISC UNIFORM FORCE
METHOD.
ALL SHEAR CONNECTIONS SHALL BE AS A MINIMUM FULL
DEPTH OF MEMBER.
ALL BOLTS SHALL BE ASTM A325 FULLY TENSIONED
BEARING BOLTS WITH SHORT SLOTTED HOLES UNLESS
NOTED. A325 SLIP CRITICAL BOLTS SHALL BE USED FOR
ALL MOMENT CONNECTIONS AND AXIALLY LOADED
MEMBERS.
ALL WELD SIZES SHOWN ARE SIZED FOR LOAD ONLY.
WELDS SHALL BE INCREASED IN SIZE AS REQUIRED TO
MEET AISC MINIMUMS.
ALL GROOVE WELDS SHOWN ARE FULL PENETRATION
WELDS UNLESS NOTED OTHERWISE.
WELDS NOTED AS PARTIAL PENETRATION GROOVE WELDS
SHOW "EFFECTIVE" SIZE OF WELD.
WELD JOINTS SHALL BE DETAILED BASED ON PROCESS
USED AND POSITION OF WELD TO MEET THE "EFFECTIVE"
SIZE SHOWN ON THE DRAWINGS.
c EXECUTION
VERIFY THAT FIELD CONDITIONS ARE ACCEPTABLE AND
ARE READY TO RECEIVE WORK.
STEEL ERECTION TOLERANCES SHALL BE IN ACCORDANCE
WITH THE CODE OF STANDARD PRACTICE.
4 MASONRY CONSTRUCTION
4.1 UNIT MASONRY
a GENERAL
MASONRY CONSTRUCTION AND MATERIALS, INCLUDING
COMPOSITION, QUALITY, STORAGE, HANDLING,
PREPARATION AND PLACEMENT OF MATERIALS, QUALITY
ASSURANCE FOR MATERIALS AND MASONRY, AND
CONSTRUCTION OF MASONRY SHALL COMPLY TO ALL
REQUIREMENTS OF "SPECIFICATIONS FOR MASONRY
STRUCTURES" (ACI 530.1/ASCE 6/TMS 602) EXCEPT AS
MODIFIED BY THE FOLLOWING NOTES.
REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
FULL ALLOWABLE STRESSES WERE USED FOR THE ASD
DESIGN OF THE MASONRY THEREFORE ALL MASONRY
WORK SHALL BE INSPECTED AND QUALITY ASSURANCE
MEASURES WILL BE IMPLEMENTED.
DEFINITIONS (SEE ACI 530.1)
REFERENCES (SEE ACI 530.1)
COMPRESSIVE STRENGTH OF MASONRY F'M SHALL BE
1,350 PSI. (MINIMUM).
SUBMITTALS
MIX DESIGNS AND TEST RESULTS FOR MORTAR TO
COMPLY WITH ASTM C270
MIX DESIGNS AND TEST RESULTS FOR GROUT TO COMPLY
WITH ASTM C476
MATERIAL CERTIFICATES:
QUALITY ASSURANCE
TESTING AGENCY SHALL COMPLY WITH THE
REQUIREMENTS OF ASTM C1093.
b MATERIALS
MORTAR: CONFORM TO ASTM C270 TYPE S PORTLAND
CEMENT TYPE 1 OR 2, LOW ALKALI PER ASTM C150 NON AIR
ENTRAINED OR HYDRATED LIME PER ASTM C207 TYPE S.
GROUT: CONFORM TO ASTM C476 WITH A COMPRESSIVE
STRENGTH OF 3,000 PSI AT 28 DAYS.
MASONRY UNITS NORMAL WEIGHT 2 CELLS PER ASTM C90
TYPE I OR TYPE II.
REINFORCING STEEL PER ASTM A615
JOINT REINFORCING PER ASTM A 951
WELDED WIRE FABRIC PER ASTM A185
ANCHOR BOLTS HEADED ASTM A307.
STEEL LINTELS ASTM A36 (A992 WIDE FLANGE SHAPES).
GALVANIZE ALL LINTELS IN EXTERIOR WALLS.
ACCESSORIES (SEE ACI 530.1)
MIXING (SEE ACI 530.1)
FABRICATION
ALL LINTELS AND STEEL CONSTRUCTION ADJACENT TO OR
ABUTTING MASONRY SHALL BE PROVIDED WITH
GALVANIZED MASONRY TIES AT 16" O.C. PROVIDE 5/8"
DIAMETER X 4" STUDS @ 32" O.C. ON TOP OF ALL WIDE
FLANGE AND CHANNEL LINTELS TO CMU.
c EXECUTION
INSPECTION (SEE ACI 530.1)
DO NOT WET CONCRETE MASONRY UNITS BEFORE
PLACING REINFORCEMENT: PLACE REINFORCEMENT IN
GROUT SPACES WITH REBAR POSITIONERS PRIOR TO
PLACING GROUT.
REINFORCEMENT SPLICES SHALL BE LAPPED 48 TIMES THE
BAR DIAMETER BUT NOT LESS THAN18".
MASONRY ERECTION
CONSTRUCT MASONRY IN RUNNING BOND UNLESS NOTED.
ALL MASONRY SHALL BE FULL BEDDED IN MORTAR (FACE
AND WEBS).
ALL MASONRY LOCATED BELOW GRADE SHALL BE
GROUTED SOLID.
PROVIDE CONTINUOUS GALVANIZED, HORIZONTAL
MASONRY REINFORCING AT 16" ON CENTER (ALTERNATE
CMU COURSES) MINIMUM.
UNDER ALL BEAM AND JOIST BEARINGS, FILL UNITS 2 CMU
COURSES DEEP X 32" WIDE MINIMUM
PROVIDE A CONTINUOUS BOND BEAM UNDER ALL JOIST
BEARINGS, AT ALL SILLS, AT TOPS OF ALL WALLS AND 8'-0"
O.C. VERTICAL.
CAST IN DOVETAIL ANCHOR SLOTS AT 16" O.C.
HORIZONTALLY AT ALL CONCRETE WALLS ADJACENT TO
OR ABUTTING MASONRY CONSTRUCTION.
PROVIDE A MINIMUM OF 2 - #5 VERTICAL BARS FOR THE
FULL HEIGHT OF MASONRY WALLS AT ENDS OF WALLS,
EACH SIDE OF OPENINGS AND EACH SIDE OF CONTROL
JOINTS UNLESS NOTED.
PROVIDE VERTICAL CONTROL JOINTS AT A MINIMUM
SPACING OF 1-1/2 TIMES THE HEIGHT OF THE WALL OR
20'-0" WHICHEVER IS LESS. REFER TO ARCHITECTURAL
DRAWINGS.
ALL OPENINGS IN MASONRY WALLS SHALL HAVE A LINTEL
PER THE LINTEL SCHEDULE. LINTELS SHALL HAVE A
MINIMUM BEARING OF 8" UNLESS NOTED.
ALL NON-LOAD BEARING CMU WALLS SHALL BE
CONSTRUCTED ON 10" THICK BY 24" WIDE.
THICKENED SLABS; REINFORCE WITH 2-#5 CONTINUOUS
BARS AND PROVIDE #5 DOWELS AT 24" ON CENTER FOR
THE CMU REINFORCING UNLESS NOTED OTHERWISE.
STRUCTURAL ABBREVIATIONS LEGEND:
A.B.S. - ANCHOR BOLTS
ARCH - ARCHITECTURAL DRAWINGS
B/ - BOTTOM OF
BOTT. - BOTTOM
CGF - COMPACTED GRANULAR FILL
CL - CENTERLINE
CMU - CONCRETE MASONRY UNITS
CONT. - CONTINUOUS
CONC - CONCRETE
E EXISTING MATERIAL
FT - FOOT
HD - HOLD DOWN
HKD - HOOKED
k - KIP
LBS - POUNDS
MEP - MECHANICAL, ELECTRICAL, PLUMBING DRAWINGS
N NEW MATERIAL
O.C. - ON CENTER
PSF - POUNDS PER SQUARE FOOT
PSI - POUNDS PER SQUARE INCH
PCF - POUNDS PER CUBIC FOOT
RD - ROOF DRAIN
STL - STEEL
SOG - SLAB ON GRADE
T/ - TOP OF
U.N. - UNLESS NOTED
VB - VAPOR BARRIER
VIF - VERIFY IN FIELD
W/ - WITH
# - POUNDS OR NUMBER
SSE - SPECIALTY STRUCTURAL ENGINEER
SER - STRUCTURAL ENGINEER OF RECORD
COR - DESIGNATED REPRESENTATIVE FOR CONSTRUCTION
RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
542-18-106
Revisions: Date:
FINAL CONCEPT DOCUMENTS SUBMISSION 15 JAN 2019
50% CONSTRUCTION DOCUMENTS SUBMISSION 16 APR 2019
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. 18-102
MOD - 50% CONSTRUCTION DOCUMENTS SUBMISSION 21 JUN 2019
100% CONSTRUCTION DOCUMENTS SUBMISSION 3 JAN 2020
T: F:
www.bancroft-ae.com www.bancroft-ae.com
30 JAN 2020
FINAL CONSTRUCTION DOCUMENTS SUBMISSION 31 JAN 2020
31 JAN 2020
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
STRUCTURAL
GENERAL NOTES
S002
MW PW
AutoCAD SHX Text
NTS
AutoCAD SHX Text
STRUCTURAL GENERAL NOTES
AutoCAD SHX Text S002
RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
542-18-106
Revisions: Date:
FINAL CONCEPT DOCUMENTS SUBMISSION 15 JAN 2019
50% CONSTRUCTION DOCUMENTS SUBMISSION 16 APR 2019
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. 18-102
MOD - 50% CONSTRUCTION DOCUMENTS SUBMISSION 21 JUN 2019
100% CONSTRUCTION DOCUMENTS SUBMISSION 3 JAN 2020
T: F:
www.bancroft-ae.com www.bancroft-ae.com
30 JAN 2020
FINAL CONSTRUCTION DOCUMENTS SUBMISSION 31 JAN 2020
31 JAN 2020
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
STRUCTURAL BASEMENT
FOUNDATION PLAN
SB100
MW PW
1 3
KEYPLAN
SB101
SB101
SB101
6" CONC. SLAB ON GRADE
T/SLAB EL.637.75(V.I.F.)
EXIST. CONC. SLAB
T/SLAB EL.639.58(V.I.F.)
EXIST. CONC. SLAB
T/SLAB EL.637.75(V.I.F.)
EXIST. CONC. SLAB
T/SLAB EL.639.58(V.I.F.)
EXIST. CONC. SLAB
T/SLAB EL.639.58(V.I.F.)
EXIST. CONC. SLAB
T/SLAB EL.640.0(V.I.F.)
RAMP DN.
RA
M
P
DN
EXISTING TRENCH(V.I.F.)
S301
SB101
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
STRUCTURAL BASEMENT FOUNDATION PLAN
S200
8"
'-5
/2
1' -3
(V
.I.F
6'-6 1/2"10'-0"
1'-3"7'-6"1'-3"
EXIST. 6" CONC. SLAB(V.I.F.)
T/SLAB EL.640.0'(V.I.F.)
(E)FOOTING
T/FOOTING
EL.638.5'(V.I.F.)
B/EXIST. FDN. WALL
EL.639.25'(V.I.F.)
TIE TO EXIST.
PER 11/S200
TIE TO EXIST.
PER 11/S200
B/ELEV. PIT
EL. 636.0'(V.I.F.)
1/
2"
(V .I.F
S201
S201
AT UNDERPIN
PATCH SOG
6'-5"
8"
'-8
5'
-2 " 3
S200
S200
S200
(E)CONC. COL.
& FOOTING(V.I.F.)
TIE TO EXIST.
PER 11/S200
TIE TO EXIST.
PER 11/S200
(E) CONC. SLAB ON GRADE
T/SLAB EL.639.58'(V.I.F.)
T/(E)FOOTING
EL.638.83'(V.I.F.)
B/(E)FDN. WALL
EL.638.83'(V.I.F.)
4' -6
4'-6"
(V.I.F.)
(V .I.F
T/(N)CONC.
EL.639.58'(V.I.F.)
T/(N)FOOTING
EL.636.58'(V.I.F.)
S200
S200
8" 9'
-4
8T
'-8
8"
'-0
'-0
C1/P1
C1/P1 F4.0
636.58' (V.I.F.)
T/(N)PIER
EL.644.17'(V.I.F.)
C1/P1
T/(N) WALL
EL.644.17'(V.I.F.)
FD
RA
MP
D
OW
N
RAMP DOWN
(E) CONC. SLAB ON GRADE
T/SLAB EL.637.75'(V.I.F.)
5'-7"(V.I.F.) 8'-3 1/2"(V.I.F.)
4' -2
3'
-6
/8
(E)CONC. COL.
& FOOTING(V.I.F.)
7' -8
/8
(V .I.F
.) TIE TO EXIST.
PER 11/S200
(V .I.F
S200
S200
S200
(E) CONC. SLAB ON GRADE
T/SLAB EL.639.58'(V.I.F.)
(E)FOOTING
T/FOOTING
EL.637.92'(V.I.F.)
(E)FOOTING
T/FOOTING
EL.638.0'(V.I.F.)
T/CONC. SLAB
EL.639.0'
(E) CONC. SLAB ON GRADE
T/SLAB EL.640.0'(V.I.F.)
6'-6 1/2" 7'-0"
8' -5
/2
2'
-6
S201
S201
SLAB, U.N.
TYP. AT NEW
RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
542-18-106
Revisions: Date:
FINAL CONCEPT DOCUMENTS SUBMISSION 15 JAN 2019
50% CONSTRUCTION DOCUMENTS SUBMISSION 16 APR 2019
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. 18-102
MOD - 50% CONSTRUCTION DOCUMENTS SUBMISSION 21 JUN 2019
100% CONSTRUCTION DOCUMENTS SUBMISSION 3 JAN 2020
T: F:
www.bancroft-ae.com www.bancroft-ae.com
30 JAN 2020
FINAL CONSTRUCTION DOCUMENTS SUBMISSION 31 JAN 2020
31 JAN 2020
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
STRUCTURAL BASEMENT
FOUNDATION PLANS
SB101
MW PW
1 UNDERPIN EXISTING FOOTING AND FOUNDATION WALL AS REQUIRED PER
DETAIL 1/S201
2 PROVIDE 6" SLAB ON GRADE REINFORCED WITH 6x6-W2.9xW2.9 WELDED
WIRE FABRIC. PLACE SLAB ON VAPOR BARRIER OVER 6" OF COMPACTED
GRANULAR FILL.
3 PROVIDE 6" SLAB ON GRADE REINFORCED WITH 6x6-W2.9xW2.9 WELDED
WIRE FABRIC. PLACE SLAB ON VAPOR BARRIER OVER FULL DEPTH
COMPACTED GRANULAR FILL.
4 PROVIDE 5" SLAB ON GRADE REINFORCED WITH 6x6-W2.9xW2.9 WELDED
WIRE FABRIC. PLACE SLAB OVER 6" OF COMPACTED GRANULAR FILL.
CONTRACTOR NOTE:
CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO BID TO
ENSURE ALL CONFLICTS FOR INSTALLATION OF NEW WORK HAS
BEEN IDENTIFIED AND ANY WORK REQUIRED TO MODIFY EXISTING IS
INCLUDED IN BID PRICE.
(E) - INDICATES EXISTING CONSTRUCTION; VERIFY IN FIELD
(N) - INDICATES PROPOSED NEW CONSTRUCTION
- INDICATES AREA OF UNDERPINNING PER DETAIL 1/S201
SEE 1/SB100
SEE 2/SB100
SEE 3/SB100
SEE 4/SB100
COLUMN SCHEDULE:
C1 - HSS5x5x3/8 GALVANIZED W/ BASE PL.3/4"x11"x11" & (4)-3/4"Ø F1554-36 A.B.S.
CAP PL. 3/4"
PIER SCHEDULE:
P1 - 16'x16" CONCRETE PIER REINF. W/ 4-#6 VERTICAL BARS & #4@12" O.C. TIES
FOOTING SCHEDULE:
F4.0 - 4'-0"x4'-0"x1'-0" W/ 5-#4 EACH WAY, BOTT.
AutoCAD SHX Text
SHEET KEY NOTES
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL SHEET NOTES
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
PARTIAL BASEMENT FOUNDATION PLAN
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATOR BASEMENT FOUNDATION PLAN
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
WEST STAIR BASEMENT FOUNDATION PLAN
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
PARTIAL BASEMENT FOUNDATION PLAN
AutoCAD SHX Text
KEYPLAN
STRUCTURAL SCHEDULES
VA Medical Center, Coatesville PA
542-18-106
Revisions: Date:
FINAL CONCEPT DOCUMENTS SUBMISSION 15 JAN 2019
50% CONSTRUCTION DOCUMENTS SUBMISSION 16 APR 2019
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. 18-102
MOD - 50% CONSTRUCTION DOCUMENTS SUBMISSION 21 JUN 2019
100% CONSTRUCTION DOCUMENTS SUBMISSION 3 JAN 2020
T: F:
www.bancroft-ae.com www.bancroft-ae.com
30 JAN 2020
FINAL CONSTRUCTION DOCUMENTS SUBMISSION 31 JAN 2020
31 JAN 2020
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
STRUCTURAL FIRST FLOOR
FRAMING PLAN
SF101
MW PW
1 3
KEYPLAN
SF104
1FIRST FLOOR LEVEL
4 FOR ROOF FRAMING PLAN
1 CAREFULLY CUT IN NEW OPENING FOR NEW MECHANICAL WORK.
COORDINATE WITH MECHANICAL SHEETS FOR EXACT LOCATION AND SIZE OF
OPENING.
REFER TO DETAIL 6/S300. DO NOT CUT JOIST RIBS.
CONTRACTOR NOTE:
CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO BID TO
ENSURE ALL CONFLICTS FOR INSTALLATION OF NEW WORK HAS
BEEN IDENTIFIED AND ANY WORK REQUIRED TO MODIFY EXISTING IS
INCLUDED IN BID PRICE.
(E) - INDICATES EXISTING CONSTRUCTION; VERIFY IN FIELD
(N) - INDICATES PROPOSED NEW CONSTRUCTION
TOP OF FINISHED FLOOR 651.0 TYP UN. VIF
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
STRUCTURAL FIRST FRAMING PLAN
AutoCAD SHX Text
SHEET KEY NOTES
AutoCAD SHX Text
GENERAL SHEET NOTES
VA Medical Center, Coatesville PA
542-18-106
Revisions: Date:
FINAL CONCEPT DOCUMENTS SUBMISSION 15 JAN 2019
50% CONSTRUCTION DOCUMENTS SUBMISSION 16 APR 2019
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. 18-102
MOD - 50% CONSTRUCTION DOCUMENTS SUBMISSION 21 JUN 2019
100% CONSTRUCTION DOCUMENTS SUBMISSION 3 JAN 2020
T: F:
www.bancroft-ae.com www.bancroft-ae.com
30 JAN 2020
FINAL CONSTRUCTION DOCUMENTS SUBMISSION 31 JAN 2020
31 JAN 2020
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
STRUCTURAL SECOND
FLOOR FRAMING PLAN
SF102
MW PW
1 3
KEYPLAN
SECOND FLOOR LEVEL
1 CAREFULLY CUT IN NEW OPENING FOR NEW MECHANICAL WORK.
COORDINATE WITH MECHANICAL SHEETS FOR EXACT LOCATION AND SIZE OF
OPENING.
REFER TO DETAIL 6/S300. DO NOT CUT JOIST RIBS.
CONTRACTOR NOTE:
CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO BID TO
ENSURE ALL CONFLICTS FOR INSTALLATION OF NEW WORK HAS
BEEN IDENTIFIED AND ANY WORK REQUIRED TO MODIFY EXISTING IS
INCLUDED IN BID PRICE.
(E) - INDICATES EXISTING CONSTRUCTION; VERIFY IN FIELD
(N) - INDICATES PROPOSED NEW CONSTRUCTION
TOP OF FINISHED FLOOR EL 663.0 UN VIF
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
STRUCTURAL SECOND FLOOR FRAMING PLAN
AutoCAD SHX Text
SHEET KEY NOTES
AutoCAD SHX Text
VA Medical Center, Coatesville PA
542-18-106
Revisions: Date:
FINAL CONCEPT DOCUMENTS SUBMISSION 15 JAN 2019
50% CONSTRUCTION DOCUMENTS SUBMISSION 16 APR 2019
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. 18-102
MOD - 50% CONSTRUCTION DOCUMENTS SUBMISSION 21 JUN 2019
100% CONSTRUCTION DOCUMENTS SUBMISSION 3 JAN 2020
T: F:
www.bancroft-ae.com www.bancroft-ae.com
30 JAN 2020
FINAL CONSTRUCTION DOCUMENTS SUBMISSION 31 JAN 2020
31 JAN 2020
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
STRUCTURAL
ATTIC FRAMING PLAN
SF103
MW PW
1 3
KEYPLAN
SF104
AHU (4,818#)
AHU (4,818#)
AHU (4,818#)
AHU (4,818#)
1 NEW AHU UNIT, COORDINATE WITH EQUIPMENT MANUFACTURER FOR FINAL
MECHANICAL UNIT FOOTPRINT DIMENSIONS.
2 CAREFULLY CUT IN NEW OPENING FOR NEW MECHANICAL WORK.
COORDINATE WITH MECHANICAL SHEETS FOR EXACT LOCATION AND SIZE OF
OPENING.
OPENING TO BE CUT BETWEEN RIBS. MAXIMUM WIDTH = 17". SEE 5/S300 &
6/S300.
3 LIVE LOAD RESTRICTED TO TYPICAL ATTIC 20 PSF IN AREAS NOTED THUS
4 TYPICAL EXISTING CONCRETE JOIST CONSTRUCTION. RIBS 25"C/C (V.I.F.).
5 TYPICAL GABLE EXISTING ROOF CONSTRUCTION 2x10 @ 24" O.C. WITH
COLLAR JOISTS.
6 REFER TO 1 & 4/S300 FOR COLLAR TIE MODIFICATION DUE TO DUCT RUNS.
7 GABLE END WALL LOUVER. SEE SECTION 1/S301.
CONTRACTOR NOTE:
CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO BID TO
ENSURE ALL CONFLICTS FOR INSTALLATION OF NEW WORK HAS
BEEN IDENTIFIED AND ANY WORK REQUIRED TO MODIFY EXISTING IS
INCLUDED IN BID PRICE.
(E) - INDICATES EXISTING CONSTRUCTION; VERIFY IN FIELD
(N) - INDICATES PROPOSED NEW CONSTRUCTION
S300
S300
HALF PLAN ROOF
RAFTERS @ 24" O.C.
HALF PLAN ATTIC
CONC. JOISTS
S300
S300
S300
S301
S301
S301
S301
S301
S301
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
STRUCTURAL ATTIC FRAMING PLAN
AutoCAD SHX Text
SHEET KEY NOTES
AutoCAD SHX Text
'-5
3/ 8"
7'-5 3/4"
S300
S300
TYP. @
ELEVATOR
OPP.
1'-3 1/8"1'-3 1/8"
10'-0"
1'- 3 1
/8"
(V .I.F
4 1 /2"
'-5
3/ 8"
7'-5 3/4"
S300
S300
TYP. @
ELEVATOR
OPP.
1'-3 1/8"1'-3 1/8"
10'-0"
1'- 3 1
/8"
(V .I.F
4 1 /2"
5 5
'-1
1 3 /8"
7'-5 3/4"
S300
S300
OPP.
1'-3 1/8"1'-3 1/8"
10'-0"
1'- 3 1
/8"
(V .I.F
4 1 /2"
7BP1
BP1
SF104
SF104
6'-8 1/2"
'-0
'-0
HSS8x4x3/8
HSS8x4x3/8
HSS8x4x3/8 BP2
BP2
BP2
HS
S8 x4 x3
/8
HS
S8 x4 x3
/8
HS
S8 x4 x3
/8
HS
S8 x4 x3
/8
S300
S300
S300
4"5'-8"
5'-8" 1'-0 1/2"
(V.I.F.)
T/(E)ATTIC
EL.675.0'
(V.I.F.)
T/CMU
EL.676.0'
COORD. W/
ARCH. SHTS.
PLYWOOD ROOF SHEATHING
2x6 RR
SIMPSON H2.5
CONT. TREATED 2x PLATE
W/ 1/2"Ø HKD. A.B.S.
@ 32" O.C.
CONT. BOND BEAM
CMU WALL
CMU REINF., SEE PLAN
2x OVERFRAMING, SEE PLAN
PLYWOOD ROOF SHEATHING
RIDGE BEAM, SEE PLAN
2x6 RR
4x4 WOOD POST
EXIST. 2x ROOF
RAFTERS (V.I.F.)
(E) CONT. 2x PLATE (V.I.F.)
(E) CMU PARAPET
WALL (V.I.F.)
RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
542-18-106
Revisions: Date:
FINAL CONCEPT DOCUMENTS SUBMISSION 15 JAN 2019
50% CONSTRUCTION DOCUMENTS SUBMISSION 16 APR 2019
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. 18-102
MOD - 50% CONSTRUCTION DOCUMENTS SUBMISSION 21 JUN 2019
100% CONSTRUCTION DOCUMENTS SUBMISSION 3 JAN 2020
T: F:
www.bancroft-ae.com www.bancroft-ae.com
30 JAN 2020
FINAL CONSTRUCTION DOCUMENTS SUBMISSION 31 JAN 2020
31 JAN 2020
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
STRUCTURAL ENLARGED
FRAMING PLANS
SF104
MW PW
1 3
KEYPLAN
1 MASONRY LINTEL 8"X8" WITH (2)#5 BOTTOM. GROUT SOLID. MINIMUM 8"
BEARING EACH SIDE OF OPENING.
2 (2)2x8 RR + 2x6 CJ
3 (2)2x8 HIP BEAM
4 2x8 @ 24" O.C. ROOF RAFTERS
5 5/8" APA SPAN RATED EXTERIOR PLYWOOD ROOF SHEATHING. NAIL
SHEATHING TO ALL SUPPORTS WITH 10d NAILS @ 6" O.C..
6 8" CMU REINFORCED WITH #5@32" O.C. VERTICAL REINFORCING FULL
HEIGHT IN FULLY GROUTED CELLS. PROVIDE MATCHING DOWELS FROM
FOUNDATION. PROVIDE ADDITIONAL 1-#5 FULL HEIGHT AT CORNERS AND
END OF WALLS. PROVIDE HORIZONTAL 8" BOND BEAMS REINFORCED WITH
2-#5 AT MAXIMUM 8" C/C VERTICALLY.
7 W8x28 ELEVATOR HOIST BEAM. REFER TO ELEVATOR SUBMITTAL FOR
LOCATION.
8 3" - 20 GA. GALVANIZED METAL ROOF DECK
9 3-L5x3 1/2x5/16 (LLV) + PL.5/16" GALVANIZED LINTEL
10 2x4@16" O.C. W/ CONT.2x4 TOP & BOTT. PLATE OVERFRAMING STUD WALLS @ 24" O.C..
11 (2)2x8 RIDGE BEAM
12 PROVIDE NEW 8" CMU EACH SIDE OF OPENING AND
OVER NEW LINTEL. REFER TO ARCHITECTURAL DWGS
FOR EXTENT. REINFORCE END CELLS WITH 1-#5 VERTICAL IN GROUTED
CELL. TOOTH INTO EXISTING MASONRY OR ADD MASONRY TIES.
CONTRACTOR NOTE:
CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO BID TO
ENSURE ALL CONFLICTS FOR INSTALLATION OF NEW WORK HAS
BEEN IDENTIFIED AND ANY WORK REQUIRED TO MODIFY EXISTING IS
INCLUDED IN BID PRICE.
(E) - INDICATES EXISTING CONSTRUCTION; VERIFY IN FIELD
(N) - INDICATES PROPOSED NEW CONSTRUCTION
- INDICATES AREA OF UNDERPINNING PER DETAIL x/Sxxx
BP1 - PL. 3/4"x7'x7" W/ (2)-1/2"Ø x 6" HEADED STUDS
MOMENT CONNECTION
NOTES:
B/DECK EL.652.25'
ALL STEEL AND CONNECTIONS
SHALL BE GALVANIZED
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
FIRST FLOOR ELEVATOR PLAN
AutoCAD SHX Text
SHEET KEY NOTES
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL SHEET NOTES
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
SECOND FLOOR ELEVATOR PLAN
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
ROOF FRAMING ELEVATOR PLAN
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
WEST STAIR ROOF FRAMING PLAN
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text 1'
AutoCAD SHX Text 1/2'
AutoCAD SHX Text 3'
AutoCAD SHX Text 3/4"=1'-0"
AutoCAD SHX Text
ROOF SECTION
AutoCAD SHX Text
SF104
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text 1'
AutoCAD SHX Text 1/2'
AutoCAD SHX Text 3'
AutoCAD SHX Text 3/4"=1'-0"
AutoCAD SHX Text
ROOF SECTION
AutoCAD SHX Text
SF104
2'-0"
1'-4"
8"
6" (V
.I.F
6"
6" (V
.I.F
2'-0"
1'-4"
8"
6" (V
.I.F
6"
(V .I.F
EXIST. CONC. SLAB (V.I.F.)
#4@12"O.C. DWLS., DRILL & EPOXY GROUT INTO
EXIST. W/ 6" MIN. EMBED.
CONT. 2-#5, T&B
#4@12"O.C.
WWF
VB
CGF
CONT. 2-#5 EXIST. CONC.
SLAB (V.I.F.)
CONC. SLAB INFILL
UNDER EXIST. SLAB
8"
T/(E)RAMP
EL.VARIES
T/(E)SLAB
EL.639.58'
(V.I.F.)
T/(N)SLAB
EL.637.75'
(V.I.F.)
EXIST. CONC. SLAB (V.I.F.)
#4@12"O.C. DWLS., DRILL & EPOXY GROUT INTO
EXIST. W/ 6" MIN. EMBED.
CONT. 2-#5, T&B
#4@12"O.C.
WWF
VB
CGF
CONT. 2-#5
T/(E)SLAB
EL.639.58'
(V.I.F.)
T/(N)SLAB
EL.637.75'
(V.I.F.)
T/LANDING
EL.637.75'
T/(N)SLAB
EL.637.75'
(V.I.F.)
T/(E)RAMP
EL.VARIES
6" (V
.I.F
8"
6"
EXIST. CONC. SLAB(V.I.F.)
#4@12"O.C. DWLS., DRILL &
EPOXY GROUT INTO EXIST. RAMP
SLAB W/ 3" EMBED.
VB
6" T/(E)SLAB
EL.639.58'
#4@12"O.C. DWLS., DRILL
& EPOXY GROUT INTO
EXIST. W/ 6" MIN. EMBED.
#4@12"O.C. DWLS., DRILL
& EPOXY GROUT INTO
EXIST. W/ 6" MIN. EMBED.
1'- 0"
1'-0"8"3'-0" 8"
1'-0"
TYP.
3/4"x3/4" CHAMFER
CONT. #5, TYP.
#4@12"O.C. DWLS.(24x24)
WWF
(E)CONC. SLAB (V.I.F.)
6"
1'- 0"
(V .I.F
#4x3'-0"LG.@12"O.C.
CENTER ON JOINT
CONT. 2x2 KEYWAY
2'-8"
4'- 0"
(M
IN
1'- 0"
1'-0"8"3'-0"
3/4"x3/4"
WWF
CGF
6"
4'- 0"
(M
IN
CHAMFER
(E)CONC. FDN. WALL
(E) CONC. SLAB
#4@12"O.C. DWLS., DRILL
& EPOXY GROUT INTO
EXIST. W/ 6" MIN. EMBED.
6" T/(E)SLAB
EL.639.58'
(V .I.F
8"
B/CONC. TO MATCH B/(N)
FOOTING
(E)CONC. FDN. WALL
(V.I.F.)
(E) CONC. SLAB
(V.I.F.)
#4@12"O.C. DWLS., DRILL
& EPOXY GROUT INTO
EXIST. W/ 6" MIN. EMBED.
6" T/(E)SLAB
EL.639.58'
(V .I.F
3'-3" (V.I.F.)
B/CONC. TO MATCH B/(N)
FOOTING
1'- 0"
1'-0"8"3'-0"
3/4"x3/4"
CHAMFER
#4 NOSING BAR @ STAIRS
#5@12"O.C.
#4@12"O.C.
(E)CONC. FDN. WALL
(V.I.F.)
6"
T/(E)SLAB
EL.640.0'
(V .I.F
(E) CONC. SLAB
(V.I.F.)
#4@12"O.C. DWLS., DRILL
& EPOXY GROUT INTO
EXIST. W/ 6" MIN. EMBED.
B/CONC. TO MATCH B/(N)
FOOTING
CONT. 2-#5, TOP&BOTT.
T/(E)SLAB
EL.639.58'
6"(V.I.F.)4'-6"(V.I.F.)6"
6"
(V .I.F
#4@12"O.C. DWLS., DRILL
& EPOXY GROUT INTO
EXIST. W/ 6" MIN. EMBED.
CGF
(E)CONC. SLAB (V.I.F.)
WWF
#4@12"O.C. DWLS., DRILL
& EPOXY GROUT INTO
EXIST. W/ 6" MIN. EMBED.
2'- 6"
(V .I.F
6" (V .I.F
4'- 0"
(M
IN
1'-0"
1'- 0"
8"1'-0"
1'- 0"
2'-0"8"1'-0"
6"
6"
3/4"x3/4"
CHAMFER
WWF
SIDEWALK, SEE ARCH. SHTS.
CONT. 2-#5
#4@12"O.C. DWLS.(24x24)
CONT. #4 NOSING BAR, TYP.
#5@12" O.C.
CONT. 2-#5, TOP,
MID., & BOTT.
BRICK VENEER, SEE ARCH. SHTS.
CMU WALL
CMU REINF., SEE PLAN
PROVIDE MATCHING DWLS.
FROM FDN.
PROVIDE MATCHING DWLS.
FROM PIT FDN.
CONT. 2x4 KEYWAY W/
CONT. WATERSTOP, TYP.
8"10'-5 1/2"1'-3"8"
1'- 0"
6" (V .I.F
9" (V
.I.F
T/FDN. WALL
EL. 6" ABOVE
FIN. GRADE
(V.I.F.)
#5@12"O.C.
#5@12"O.C.
9"
(V .I.F
8"
(V .I.F
SUMPPIT, SEE
10/S200
B/ ELEV. PIT
SUMP PIT, SEE
ELEV. MFR. DWGS.
SU
MP
P
IT
, S
EE
EL
EV
. M
FR
. D W
GS
1'- 0"
1'-0" 1'-0"
CONTINUE ELEV. PIT
REINF. THRU SUMP PIT
EXIST. WALL NEW WALL
ROUGHEN FACE OF WALL & FTG.
TO 1/4" AMPLITUDE & PROVIDE
BONDING AGENT PRIOR TO PLACEMENT
OF NEW CONCRETE
#5 BARS x 3'-6" LONG, DRILL IN
6" INTO EXIST. WALL & SET WITH
EPOXY GROUT. PROVIDE 2 BARS
@ 24" O.C. VERT. IN WALL, 3 BARS
AT FOOTING
IF WALL HEIGHT IS LESS THAN 4'-0", PROVIDE
TOTAL 3 BARS AT WALL & BARS AT FOOTING
CONT. 2-#4
#4@12"O.C.
2'-0"
UNDERPIN EXISTING FOOTING
PER
8"8"
COLUMN, SEE
PLAN & SCHED.
ANCHOR RODS,
SEE SCHED.
BASE PLATE, SEE
NOTES ON SHT. SB101
SETTING PL. 1/4"
3/4"± NON-SHRINK
GROUT
CONC. PIER, SEE
PLAN & SCHED.
T/ CONC.
EL.SEE ARCH.
& CIVIL SHTS.
T/(E)SLAB
EL.639.58'
T/ WALL
EL.644.17'
T/ WALL
EL.644.17'
4 1/2"
(V.I.F.)
CONT. 2-#5,TOP & BOTT.
#6@12"O.C.
#5@12"O.C.
6"
6"
FIELD VERIFY
4'- 0"
#6@12"O.C.
#5@12"O.C.
T/ WALL
EL.644.17'
GUARDRAIL, SEE
ARCH. SHTS.
CONT.2-#5, TOP & BOTT.
#6@12"O.C.
#5@12"O.C.
7-#5
#5@12"O.C.
6-#5
#5@12"O.C.
T/BRICK LEDGE
SEE ARCH. SHTS.
7" 8"
NOTE:
COORD. W/ STEAM LOOP PROJECT
REF. G1.002 GENERAL NOTES -
BASEMENT STEAM / UTILITY PIT
RENOVATE BUILDING 4A&B FLOORS
OUTPATIENT MENTAL HEALTH CLINIC
VA Medical Center, Coatesville PA
542-18-106
Revisions: Date:
FINAL CONCEPT DOCUMENTS SUBMISSION 15 JAN 2019
50% CONSTRUCTION DOCUMENTS SUBMISSION 16 APR 2019
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
A
B
C
D
E
F
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Drawing Title
Approved: Project Director
Phase Project Title Project Number
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
VA FORM 08-6231
FULLY SPRINKLERED
Bancroft Project No. 18-102
MOD - 50% CONSTRUCTION DOCUMENTS SUBMISSION 21 JUN 2019
100% CONSTRUCTION DOCUMENTS SUBMISSION 3 JAN 2020
T: F:
www.bancroft-ae.com www.bancroft-ae.com
30 JAN 2020
FINAL CONSTRUCTION DOCUMENTS SUBMISSION 31 JAN 2020
31 JAN 2020
FINAL CONSTRUCTION
DOCUMENTS SUBMISSION
FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION
STRUCTURAL
FOUNDATION DETAILS
S200
MW PW
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 1/2"=1'-0"
AutoCAD SHX Text
SECTION @ LACTATION
AutoCAD SHX Text S200
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 1/2"=1'-0"
AutoCAD SHX Text
SECTION @ LACTATION
AutoCAD SHX Text S200
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1'
Auto…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .