00 General 54218106_Drawings_ADD-01_080320.pdf

PDF 2 MB Posted

Attached to
Z2DA--Renovate Building 4 A + B Floors Outpatient Mental Health Clinic, Project No. 542-18-106
Solicitation number
36C24420B0003
Issued by

About this file

This solicitation package is for a construction project to renovate two floors of an existing VA building into an outpatient mental health clinic. The scope of work includes demolishing and renovating approximately 28,000 square feet of space on the first and second floors as well as 3,000 square feet in the basement wing. Disciplines involved are site work, structural, hazardous materials abatement, architectural, fire protection, mechanical, plumbing and electrical construction. The project has a maximum completion time of 588 calendar days from notice to proceed.

This opportunity is only available to verified Service-Disabled Veteran-Owned Small Businesses. The solicitation documents and drawings will be available for download on June 23, 2020 from SAM.gov. A pre-bid site visit will be scheduled. Interested contractors must be able to provide 100% performance and payment bonds and a 20% bid guarantee. The contract type is firm fixed price. The magnitude of this procurement is between $10-20 million, using NAICS code 236220 with a small business size standard of $39.5 million.

View the file

Other files

File Type Posted
Award Announcement 36C24420C0112.pdf PDF
General Decision Number PA20200083.pdf PDF
36C24420B0003 0003.pdf PDF
00 01 15 - List of Drawing Sheets - ADD-01.pdf PDF
07 Architecture.pdf PDF
36C24420B0003 Amendment 0002.pdf PDF
10 22 26.13 - Operable Partitions - ADD-01.pdf PDF
RFI LOG_542-18-106_08052020.r2.pdf PDF
Sign In Sheet no. 3 B4A B 07162020.pdf PDF
Sign In Sheet B4A B 07162020.pdf PDF
03 Structural 54218106_Drawings_ADD-01_080320.pdf PDF
A012 54218106_Drawings_FinalCD_013120.pdf PDF
08 Interiors 54218106_Drawings_ADD-01_080320.pdf PDF
07 13 52 - Modified Bituminous Sheet Waterproofing - ADD-01.pdf PDF
07 60 00 - Flashing and Sheet Metal - ADD-01.pdf PDF
01 33 23 - Shop Drawings Product Data Samples - ADD-01.pdf PDF
00 01 10 - TOC - ADD-01.pdf PDF
11 Plumbing 54218106_Drawings_ADD-01_080320.pdf PDF
ADD-01 Narrative.pdf PDF
10 21 13 - Toilet Compartments - ADD-01.pdf PDF
07 27 27 - Fluid-Applied Membrane Air Barrier Vapor Retardg - ADD-01.pdf PDF
11 73 00 - Ceiling Mounted Patient Lift System - ADD-01.pdf PDF
36C24420B0003 Amendment 0001 - Attachment.pdf PDF
36C24420B0003 AMENDMENT 0001.pdf PDF
36C24420B0003 MAP for Site Visit.pdf PDF
04 Structural 54218106_Drawings_FinalCD_013120.pdf PDF
10 Mechanical 54218106_Drawings_FinalCD_013120.pdf PDF
06 Interiors 54218106_Drawings_FinalCD_013120.pdf PDF
09 Plumbing 54218106_Drawings_FinalCD_013120.pdf PDF
08 Fire Protection 54218106_Drawings_FinalCD_013120.pdf PDF
02 Hazardous 54218106_Drawings_FinalCD_013120.pdf PDF
07 Equipment 54218106_Drawings_FinalCD_013120.pdf PDF
01 General 54218106_Drawings_FinalCD_013120.pdf PDF
05 Architectural 54218106_Drawings_FinalCD_013120.pdf PDF
11 Electrical 54218106_Drawings_FinalCD_013120.pdf PDF
03 Civil Landscape 54218106_Drawings_FinalCD_013120.pdf PDF
54218106-Spec-Vol 3_FinalCD_013120.pdf PDF
36C24420B0003.docx DOCX document
PCRA 3-2019 building 4.pdf PDF
54218106-Spec-Vol 2_FinalCD_013120.pdf PDF
54218106-Spec-Vol 1_FinalCD_013120.pdf PDF
COVID Guidelines.pdf PDF
54218106-Spec-Vol 4_FinalCD_013120.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Drawing Title

Approved: Project Director

Phase Project Title Project Number

Building Number

Drawing NumberLocation

Issue Date Checked Drawn

VA FORM 08-6231

FULLY SPRINKLERED

FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION

03 AUG 2020

SHEET INDEX RENOVATE BUILDING 4A&B FLOORS

OUTPATIENT MENTAL HEALTH CLINIC

VA Medical Center, Coatesville PA

RFR BAE

542-18-106

G002

FINAL CONSTRUCTION

DOCUMENTS SUBMISSION

SHEET INDEX

NUMBER TITLE DRAWN BY

FINAL

CONCEPT

50% MOD - 50% 100% FINAL

PD101.3 PLUMBING - FISRT FLOOR DEMOLITION PLAN ZONE 3 BAE • • • • •

PD101.4 PLUMBING - FISRT FLOOR DEMOLITION PLAN ZONE 4 BAE • • • • •

PD102.1 PLUMBING - SECOND FLOOR DEMOLITION PLAN ZONE 1 BAE • • • • •

PD102.2 PLUMBING - SECOND FLOOR DEMOLITION PLAN ZONE 2 BAE • • • • •

PD102.3 PLUMBING - SECOND FLOOR DEMOLITION PLAN ZONE 3 BAE • • • • •

PD102.4 PLUMBING - SECOND FLOOR DEMOLITION PLAN ZONE 4 BAE • • • • •

PD103.1 PLUMBING - ATTIC DEMOLITION PLAN ZONE 1 BAE • • • •

PD103.2 PLUMBING - ATTIC DEMOLITION PLAN ZONE 2 BAE • • • •

PD103.3 PLUMBING - ATTIC DEMOLITION PLAN ZONE 3 BAE • • • •

PD103.4 PLUMBING - ATTIC DEMOLITION PLAN ZONE 4 BAE • • • •

P010U PLUMBING - UNDERGROUND PLAN BAE • •

P010 PLUMBING - BASEMENT PLAN BAE • •

P011 PLUMBING - FIRST FLOOR PLAN BAE • •

P012 PLUMBING - SECOND FLOOR PLAN BAE • •

P013 PLUMBING - ATTIC PLAN BAE • •

P100U.1 PLUMBING - UNDERGROUND PLAN ZONE 1 BAE • • •

P100U.2 PLUMBING - UNDERGROUND PLAN ZONE 2 BAE • • •

P100U.3 PLUMBING - UNDERGROUND PLAN ZONE 3 BAE • • •

P100U.4 PLUMBING - UNDERGROUND PLAN ZONE 4 BAE • • •

P100.1 PLUMBING - BASEMENT PLAN ZONE 1 BAE • • • •

P100.2 PLUMBING - BASEMENT PLAN ZONE 2 BAE • • • •

P100.3 PLUMBING - BASEMENT PLAN ZONE 3 BAE • • • •

P100.4 PLUMBING - BASEMENT PLAN ZONE 4 BAE • • • •

P101.1 PLUMBING - FIRST FLOOR PLAN ZONE 1 BAE • • • •

P101.2 PLUMBING - FIRST FLOOR PLAN ZONE 2 BAE • • • •

P101.3 PLUMBING - FIRST FLOOR PLAN ZONE 3 BAE • • • •

P101.4 PLUMBING - FIRST FLOOR PLAN ZONE 4 BAE • • • •

P102.1 PLUMBING - SECOND FLOOR PLAN ZONE 1 BAE • • • •

P102.2 PLUMBING - SECOND FLOOR PLAN ZONE 2 BAE • • • •

P102.3 PLUMBING - SECOND FLOOR PLAN ZONE 3 BAE • • • •

P102.4 PLUMBING - SECOND FLOOR PLAN ZONE 4 BAE • • • •

P103.1 PLUMBING - ATTIC PLAN ZONE 1 BAE • • • •

P103.2 PLUMBING - ATTIC PLAN ZONE 2 BAE • • • •

P103.3 PLUMBING - ATTIC PLAN ZONE 3 BAE • • • •

P103.4 PLUMBING - ATTIC PLAN ZONE 4 BAE • • • •

P500 PLUMBING - DETAILS BAE • • • •

P501 PLUUMBING - DETAILS BAE • •

P600 PLUMBING - DOMESTIC WATER RISER DIAGRAMS BAE • •

P601 PLUMBING - SANITARY AND VENT RISER DIAGRAMS BAE • •

P602 PLUMBING - STORM RISER DIAGRAM BAE • •

P700 PLUMBING - SCHEDULES BAE • •

13 -MECHANICAL

M001 MECHANICAL SYMBOLS, ABBREVIATIONS, AND NOTES BAE • • • • •

MVD100 BASEMENT MECHANICAL VENTILATION DEMOLITION PLAN BAE • • •

MVD101 FIRST FLOOR MECHANICAL VENTILATION DEMOLITION PLAN BAE • • •

MVD102 SECOND FLOOR MECHANICAL VENTILATION DEMOLITION PLAN BAE • • •

MVD103 ATTIC VENTILATION DEMOLITION PLAN BAE • • •

MPD100 BASEMENT PIPING DEMOLITION PLAN BAE • • •

MPD101 FIRST FLOOR PIPING DEMOLITION PLAN BAE • • •

MPD102 SECOND FLOOR PIPING DEMOLITION PLAN BAE • • •

MV010 BASEMENT MECHANICAL PLAN BAE • • •

MV100.1 MECHANICAL VENTILATION - BASEMENT PLAN ZONE 1 BAE • • •

MV100.2 MECHANICAL VENTILATION - BASEMENT PLAN ZONE 2 BAE • • •

MV100.3 MECHANICAL VENTILATION - BASEMENT PLAN ZONE 3 BAE • • • •

MV100.4 MECHANICAL VENTILATION - BASEMENT PLAN ZONE 4 BAE • • • •

MV011 FIRST FLOOR MECHANICAL PLAN BAE • • •

MV101.1 MECHANICAL VENTILATION - FIRST FLOOR PLAN ZONE 1 BAE • • • •

MV101.2 MECHANICAL VENTILATION - FIRST FLOOR PLAN ZONE 2 BAE • • • •

MV101.3 MECHANICAL VENTILATION - FIRST FLOOR PLAN ZONE 3 BAE • • • •

MV101.4 MECHANICAL VENTILATION - FIRST FLOOR PLAN ZONE 4 BAE • • • •

MV012 SECOND FLOOR MECHANICAL PLAN BAE • • •

MV102.1 MECHANICAL VENTILATION - SECOND FLOOR PLAN ZONE 1 BAE • • • •

MV102.2 MECHANICAL VENTILATION - SECOND FLOOR PLAN ZONE 2 BAE • • • •

MV102.3 MECHANICAL VENTILATION - SECOND FLOOR PLAN ZONE 3 BAE • • • •

MV102.4 MECHANICAL VENTILATION - SECOND FLOOR PLAN ZONE 4 BAE • • • •

MV013 ATTIC MECHANICAL VENTILATION PLAN BAE • • •

MP100 MECHANICAL PIPING - BASEMENT PLAN BAE • • •

MP101 MECHANICAL PIPING - FIRST FLOOR PLAN BAE • • •

MP102 MECHANICAL PIPING - SECOND FLOOR PLAN BAE • • •

MP103 MECHANICAL PIPING - ATTIC PLAN BAE • • •

M400 MECHANICAL - ENLARGED SECTIONS - 4-AC-3 BAE • •

M401 MECHANICAL - ENLARGED SECTIONS - 4-AC-4 BAE • •

M402 MECHANICAL - ENLARGED SECTIONS - 4-AC-5 BAE • •

M403 MECHANICAL - ENLARGED SECTIONS - 4-AC-6 BAE • •

M500 MECHANICAL DETAILS BAE • • •

M501 MECHANICAL DETAILS BAE • • •

M502 MECHANICAL DETAILS BAE • • •

M503 MECHANICAL DETAILS BAE • •

M600 MECHANICAL SCHEDULES BAE • • • •

M601 MECHANICAL SCHEDULES BAE • • •

M700 TEMPERATURE CONTROLS AND POINTS LIST BAE • • •

M701 TEMPERATURE CONTROLS AND POINTS LIST BAE • • •

M702 TEMPERATURE CONTROLS AND POINTS LIST BAE • • •

NUMBER TITLE DRAWN BY

FINAL

CONCEPT

50% MOD - 50% 100% FINAL

A414 INTERIOR ELEVATIONS BAE • •

A430 TYPICAL ROOMS BAE • •

A431 TYPICAL ROOMS BAE • •

A432 TYPICAL ROOMS BAE • •

A440 ENLARGED PLANS - ELEVATOR BAE • • • •

A441 ENLARGED FLOOR PLAN - STAIRS BAE • • • •

A442 ENLARGED FLOOR PLANS AND DETAILS BAE • • • •

A443 PLANS AND SECTIONS - ELEVATOR SERVICE ROOM 2 BAE • •

A444 ENLARGED FLOOR PLANS AND ELEVATIONS - LACT. ROOM BAE • •

A501 PARTITION SCHEDULE AND DETAILS BAE • • • •

A502 DETAILS BAE • •

A503 DETAILS BAE • •

A505 ROOF DETAILS BAE • •

A510 EXTERIOR DETAILS BAE • •

A511 EXTERIOR DETAILS BAE • •

A512 INTERIOR DETAILS BAE • •

A513 EXTERIOR DETAILS BAE • •

A515 INTERIOR DETAILS BAE • •

A530 CEILING & MISC DETAILS BAE • •

A550 CASEWORK DETAILS BAE • •

A601 DOOR & FRAME SCHEDULES & DETAILS BAE • • • •

A602 DOOR DETAILS BAE • •

A603 DOOR DETAILS BAE • •

A610 SCHEDULES & DETAILS - WINDOWS & LOUVERS BAE • • •

08 - INTERIORS

I601 FINISH SCHEDULE - BASEMENT AND FIRST FLOOR BAE • • •

I602 FINISH SCHEDULE AND LEGEND - SECOND FLOOR BAE • •

I620 SIGNAGE TYPES BAE • •

I621 SIGNAGE TYPES & MOUNTING HEIGHTS BAE • •

I622 SIGNAGE SCHEDULE BAE • •

IF100.1 BASEMENT - FLOOR AND W.P. FINISH PLAN ZONE 1 BAE • •

IF100.2 BASEMENT - FLOOR AND W.P. PARTIAL FINISH PLAN ZONE 2 BAE • •

IF100.4 BASEMENT - FLOOR AND W.P. PARTIAL FINISH PLAN ZONE 4 BAE •

IF101.1 FIRST FLOOR - FLOOR & W.P. PARTIAL FINISH PLAN ZONE 1 BAE • •

IF101.2 FIRST FLOOR - FLOOR & W.P. PARTIAL FINISH PLAN ZONE 2 BAE • •

IF101.3 FIRST FLOOR - FLOOR & W.P. PARTIAL FINISH PLAN ZONE 3 BAE • •

IF101.4 FIRST FLOOR - FLOOR & W.P. PARTIAL FINISH PLAN ZONE 4 BAE • •

IF102.1 SECOND FLOOR - FLOOR & W.P PARTIAL FINISH PLAN ZONE 1 BAE • •

IF102.2 SECOND FLOOR - FLOOR & W.P PARTIAL FINISH PLAN ZONE 2 BAE • •

IF102.3 SECOND FLOOR - FLOOR& W.P PARTIAL FINISH PLAN ZONE 3 BAE • •

IF102.4 SECOND FLOOR - FLOOR & W.P PARTIAL FINISH ZONE 4 BAE • •

IG100 BASEMENT SIGNAGE PLAN BAE • •

IG101 FIRST FLOOR SIGNAGE PLAN BAE • •

IG102 SECOND FLOOR SIGNAGE PLAN BAE • •

09 - EQUIPMENT

QH010 GENERAL EQUIPMENT PLAN - BASEMENT BAE • •

QH011 GENERAL EQUIPMENT PLAN - FIRST FLOOR BAE • •

QH012 GENERAL EQUIPMENT PLAN - SECOND FLOOR BAE • •

QH100.1 EQUIPMENT PLAN - BASEMENT ZONE 1 BAE • • •

QH100.2 EQUIPMENT PLAN - BASEMENT ZONE 2 BAE • • •

QH100.3 EQUIPMENT PLAN - BASEMENT ZONE 3 BAE • • •

QH100.4 EQUIPMENT PLAN - BASEMENT ZONE 4 BAE • • •

QH101.1 EQUIPMENT PLAN - FIRST FLOOR ZONE 1 BAE • • • •

QH101.2 EQUIPMENT PLAN - FIRST FLOOR ZONE 2 BAE • • • •

QH101.3 EQUIPMENT PLAN - FIRST FLOOR ZONE 3 BAE • • • •

QH101.4 EQUIPMENT PLAN - FIRST FLOOR ZONE 4 BAE • • • •

QH102.1 EQUIPMENT PLAN - SECOND FLOOR ZONE 1 BAE • • • •

QH102.2 EQUIPMENT PLAN - SECOND FLOOR ZONE 2 BAE • • • •

QH102.3 EQUIPMENT PLAN - SECOND FLOOR ZONE 3 BAE • • • •

QH102.4 EQUIPMENT PLAN - SECOND FLOOR ZONE 4 BAE • • • •

QH601 EQUIPMENT SCHEDULE BAE • • • •

QH602 EQUIPMENT SCHEDULE BAE • • • •

QH603 EQUIPMENT SCHEDULE BAE • • • •

QH604 EQUIPMENT SCHEDULE BAE • • • •

QH605 EQUIPMENT SCHEDULE BAE • •

QH606 EQUIPMENT SCHEDULE BAE • •

QH607 EQUIPMENT SCHEDULE BAE • •

10 - FIRE PROTECTION

F001 FIRE PROTECTION GENERAL NOTES AND SYMBOLS BAE • • • • •

FD100 BASEMENT FIRE PROTECTION DEMO PLAN BAE • • • • •

FD101 FIRST FLOOR FIRE PROTECTION DEMO PLAN BAE • • • • •

FD102 SECOND FLOOR FIRE PROTECTION DEMO PLAN BAE • • • • •

FD103 ATTIC FIRE PROTECTION DEMO PLAN BAE • • • • •

FX100 BASEMENT FIRE PROTECTION PLAN BAE • • • •

FX101 FIRST FLOOR FIRE PROTECTION PLAN BAE • • • •

FX102 SECOND FLOOR FIRE PROTECTION PLAN BAE • • • •

FX103 ATTIC FIRE PROTECTION PLAN BAE • • • •

FX500 FIRE PROTECTION DETAILS BAE • • • •

FX501 FIRE PROTECTION RISER DIAGRAM BAE • •

11 - PLUMBING

P001 PLUMBING - GENERAL NOTES AND SYMBOLS BAE • • • • •

PD010U PLUMBING - UNDERGROUND DEMOLITION PLAN BAE • •

PD010 PLUMBING - BASEMENT DEMOLITION PLAN BAE • •

PD011 PLUMBING - FIRST FLOOR DEMOLITION PLAN BAE • •

PD012 PLUMBING - SECOND FLOOR DEMOLITION PLAN BAE • •

PD013 PLUMBING - ATTIC FLOOR DEMOLITION PLAN BAE • •

PD100U.1 PLUMBING - UNDERGROUND DEMOLITION PLAN ZONE 1 BAE • • •

PD100U.2 PLUMBING - UNDERGROUND DEMOLITION PLAN ZONE 2 BAE • • •

PD100U.3 PLUMBING - UNDERGROUND DEMOLITION PLAN ZONE 3 BAE • • •

PD100U.4 PLUMBING - UNDERGROUND DEMOLITION PLAN ZONE 4 BAE • • •

PD100.1 PLUMBING - BASEMENT DEMOLITION PLAN ZONE 1 BAE • • • • •

PD100.2 PLUMBING - BASEMENT DEMOLITION PLAN ZONE 2 BAE • • • • •

PD100.3 PLUMBING - BASEMENT DEMOLITION PLAN ZONE 3 BAE • • • • •

PD100.4 PLUMBING - BASEMENT DEMOLITION PLAN ZONE 4 BAE • • • • •

PD101.1 PLUMBING - FISRT FLOOR DEMOLITION PLAN ZONE 1 BAE • • • • •

PD101.2 PLUMBING - FISRT FLOOR DEMOLITION PLAN ZONE 2 BAE • • • • •

NUMBER TITLE DRAWN BY

FINAL

CONCEPT

50% MOD - 50% 100% FINAL

00 - GENERAL

G001 COVER SHEET BAE • • • • •

G002 SHEET INDEX BAE • • • • •

G003 CODE AND BUILDING INFORMATION, PROJECT TEAM BAE • • • •

GI001 GENERAL NOTES, SAFETY NOTES, BOD COMPLIANCE BAE • • • •

GI002 NOTES, OCCUPIED AREAS, SCHEDULING OF WORK, SPS BAE • • • •

GI003 GENERAL - DEMOLITION NOTES BAE • • • •

GI100 LIFE SAFETY PLAN - BASEMENT BAE • • • • •

GI101 LIFE SAFETY PLAN - FIRST FLOOR BAE • • • • •

GI102 LIFE SAFETY PLAN - SECOND FLOOR BAE • • • • •

GI400 INFECTION CONTROL NOTES & DETAILS BAE • • • •

GI410 BASEMENT - INFECTION CONTROL PLAN BAE • • • •

GI411 FIRST FLOOR - INFECTION CONTROL PLAN BAE • • • •

GI412 SECOND FLOOR - INFECTION CONTROL PLAN BAE • • • •

01 - HAZARDOUS

HA100 BASEMENT ASBESTOS ABATEMENT PLAN 1SOURCE • •

HA101 FIRST FLOOR ASBESTOS ABATEMENT PLAN 1SOURCE • •

HA102 SECOND FLOOR ASBESTOS ABATEMENT PLAN 1SOURCE • •

04 - CIVIL

C101 EXISTING CONDITIONS AND DEMOLITION PLAN PTE • • •

C102 LAYOUT PLAN PTE • • •

C103 GRADING PLAN PTE • • •

C104 UTILITY PLAN PTE • • •

C105 LANDSCAPE PLAN PTE • • •

C106 CONSTRUCTION DETAILS PTE • • •

C107 CONSTRUCTION DETAILS PTE •

06 - STRUCTURAL

S001 STRUCTURAL GENERAL NOTES JWA • •

S002 STRUCTURAL GENERAL NOTES JWA • •

SB100 STRUCTURAL BASEMENT FOUNDATION PLAN JWA •

SB101 STRUCTURAL BASEMENT FOUNDATION PLANS JWA • • •

SF101 STRUCTURAL FIRST FLOOR FRAMING PLAN JWA • • •

SF102 STRUCTURAL SECOND FLOOR FRAMING PLAN JWA • •

SF103 STRUCTURAL ATTIC FRAMING PLAN JWA • • •

SF104 STRUCTURAL ENLARGED FRAMING PLAN JWA • • •

S200 STRUCTURAL FOUNDATION DETAILS JWA • • •

S201 STRUCTURAL FOUNDATION DETAILS JWA • •

S300 STRUCTURAL FRAMING DETAILS JWA • • •

S301 STRUCTURAL FRAMING DETAILS JWA • •

07 - ARCHITECTURAL

A001 ARCHITECTURAL ABBREVIATIONS & SYMBOLS BAE • • • •

A002 STANDARD MOUNTING HEIGHTS BAE •

AD100 ARCHITECTURAL DEMO PLAN - BASEMENT BAE • • • • •

AD101 ARCHITECTURAL DEMO PLAN - FIRST FLOOR BAE • • • • •

AD102 ARCHITECTURAL DEMO PLAN - SECOND FLOOR BAE • • • • •

AD103 ARCHITECTURAL DEMO PLAN - ATTIC BAE • • • •

AD130 REFLECTED CEILING DEMOLITION PLAN - BASEMENT BAE • • • •

AD131 REFLECTED CEILING DEMOLITION PLAN - FIRST FLOOR BAE • • • •

AD131A ABOVE CEILING DEMOLITION PLAN - FIRST FLOOR BAE • • • •

AD132 REFLECTED CEILING DEMO PLAN - SECOND FLOOR BAE • • • •

AD132A ABOVE CEILING DEMOLITION PLAN - SECOND FLOOR BAE • • • •

A010 GENERAL ARRANGEMENT PLAN - BASEMENT BAE • • • • •

A011 GENERAL ARRANGEMENT PLAN - FIRST FLOOR BAE • • • • •

A012 GENERAL ARRANGEMENT PLAN - SECOND FLOOR BAE • • • • •

A013 GENERAL ARRANGEMENT PLAN - ATTIC BAE • • • •

A014 ROOF PLAN BAE • •

A015 REFLECTED CEILING PLAN - BASEMENT OVERALL BAE • • • •

A016 REFLECTED CEILING PLAN - FIRST FLOOR OVERALL BAE • • • •

A017 REFLECTED CEILING PLAN - SECOND FLOOR OVERALL BAE • • • •

A100.1 ARCHITECTURAL PLAN - BASEMENT ZONE 1 BAE • • •

A100.2 ARCHITECTURAL PLAN - BASEMENT ZONE 2 BAE • • •

A100.3 ARCHITECTURAL PLAN - BASEMENT ZONE 3 BAE • • •

A100.4 ARCHITECTURAL PLAN - BASEMENT ZONE 4 BAE • • •

A101.1 ARCHITECTURAL PLAN - FIRST FLOOR ZONE 1 BAE • • • •

A101.2 ARCHITECTURAL PLAN - FIRST FLOOR ZONE 2 BAE • • • •

A101.3 ARCHITECTURAL PLAN - FIRST FLOOR ZONE 3 BAE • • • •

A101.4 ARCHITECTURAL PLAN - FIRST FLOOR ZONE 4 BAE • • • •

A102.1 ARCHITECTURAL PLAN - SECOND FLOOR ZONE 1 BAE • • • •

A102.2 ARCHITECTURAL PLAN - SECOND FLOOR ZONE 2 BAE • • • •

A102.3 ARCHITECTURAL PLAN - SECOND FLOOR ZONE 3 BAE • • • •

A102.4 ARCHITECTURAL PLAN - SECOND FLOOR ZONE 4 BAE • • • •

A103.1 ARCHITECTURAL PLAN - ATTIC ZONE 1 BAE • • •

A103.2 ARCHITECTURAL PLAN - ATTIC ZONE 2 BAE • • •

A103.3 ARCHITECTURAL PLAN - ATTIC ZONE 3 BAE • • •

A103.4 ARCHITECTURAL PLAN - ATTIC ZONE 4 BAE • • •

A130.1 REFLECTED CEILING PLAN - BASEMENT ZONE 1 BAE • • •

A130.2 REFLECTED CEILING PLAN - BASEMENT ZONE 2 BAE • • •

A130.3 REFLECTED CEILING PLAN - BASEMENT ZONE 3 BAE • • •

A130.4 REFLECTED CEILING PLAN - BASEMENT ZONE 4 BAE • • •

A131.1 REFLECTED CEILING PLAN - FIRST FLOOR ZONE 1 BAE • • • •

A131.2 REFLECTED CEILING PLAN - FIRST FLOOR ZONE 2 BAE • • • •

A131.3 REFLECTED CEILING PLAN - FIRST FLOOR ZONE 3 BAE • • • •

A131.4 REFLECTED CEILING PLAN - FIRST FLOOR ZONE 4 BAE • • • •

A132.1 REFLECTED CEILING PLAN - SECOND FLOOR ZONE 1 BAE • • • •

A132.2 REFLECTED CEILING PLAN - SECOND FLOOR ZONE 2 BAE • • • •

A132.3 REFLECTED CEILING PLAN - SECOND FLOOR ZONE 3 BAE • • • •

A132.4 REFLECTED CEILING PLAN - SECOND FLOOR ZONE 4 BAE • • • •

A201 EXTERIOR ELEVATIONS - NORTH & SOUTH BAE • • • •

A202 EXTERIOR ELEVATIONS - EAST & WEST BAE • • • •

A301 SECTIONS BAE • • • •

A302 SECTIONS BAE • • • •

A401 INTERIOR ELEVATIONS BAE • • •

A402 INTERIOR ELEVATIONS BAE • •

A403 INTERIOR ELEVATIONS BAE • •

A404 INTERIOR ELEVATIONS BAE • •

A411 TOILET INTERIOR ELEVATIONS BAE • •

Revisions: Date:

FINAL CONCEPT DOCUMENTS SUBMISSION 15 JAN 2019

50% CONSTRUCTION DOCUMENTS SUBMISSION 16 APR 2019

MOD - 50% CONSTRUCTION DOCUMENTS SUBMISSION 21 JUN 2019

100% CONSTRUCTION DOCUMENTS SUBMISSION 3 JAN 2020

FINAL CONSTRUCTION DOCUMENTS SUBMISSION 31 JAN 2020

ADDENDUM 1 03 AUG 2020

A

B

C

D

E

F

A

B

C

D

E

F

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

Drawing Title

Approved: Project Director

Phase Project Title Project Number

Building Number

Drawing NumberLocation

Issue Date Checked Drawn

VA FORM 08-6231

FULLY SPRINKLERED

FINAL CONSTRUCTION DOCUMENTS - NOT FOR CONSTRUCTION

03 AUG 2020

CODE AND BUILDING

INFORMATION, PROJECT TEAM

RENOVATE BUILDING 4A&B FLOORS

OUTPATIENT MENTAL HEALTH CLINIC

VA Medical Center, Coatesville PA

RFR BAE

542-18-106

G003

FINAL CONSTRUCTION

DOCUMENTS SUBMISSION

FIRE RESISTIVE RATINGS

ROOF CONSTRUCTION

EXTERIOR NON-BEARING WALLS

SUPPORTING ROOF ONLY

SUPPORTING MORE THAN ONE FLOOR

COLUMNS & BEAMS

FLOOR CONSTRUCTION 0-HOUR

1-HOUR

BOILER AND FUEL - FIRED EQUIPMENT

2-HOURS

0-HOUR

38.3.2.2

* NOTE - IF BUILDING PROTECTED THROUGHOUT BY APPROVED AUTOMATIC SPRINKLER

SYSTEM IN ACCORDANCE WITH (NFPA 101) 9.7.1.1(1) OR (IBC)903.3.1

SHAFT ENCLOSURES 1-HOUR

TABLE 509

713.4

1. CONSTRUCTION CLASSIFICATIONS: TYPE 3B

2. AUTOMATIC FIRE SUPPRESSION: ALL AREAS IN ACCORDANCE WITH NFPA 13

3. OCCUPANCY CLASSIFICATIONS: (B) BUSINESS, NFPA 101 NEW / EXISTING BUSINESS OCCUPANCY

4. AREA OF WORK: PROJECT AREA APPROXIMATELY 28,000 SF WITH 15,000 SF ON FIRST FLOOR, 13,000 SF ON

SECOND FLOOR, INCIDENTAL SUPPORTING WORK IN THE 15,000 SF BASEMENT AND 13,000 SF

ATTIC SPACE.

5. BUILDING: EXISTING STAND-ALONE CONCRETE AND MASONRY STRUCTURE WAS BUILT IN 1929. THE

BUILDING IS CURRENTLY USED FOR OFFICES AND MEDICAL RECORDS SERVICE (2ND FLOOR),

DOMICILIARY (1ST FLOOR), AND STERILE PROCESSING SERVICE (SPS), OFFICES, AND

MAINTENANCE (BASEMENT)(SPS). THE BUILDING HAS (3) OCCUPIED FLOORS (BASEMENT, FIRST, AND SECOND FLOORS) AND AN ATTIC SPACE USED AS A MECHANICAL PENTHOUSE. EXTERIOR

RENOVATIONS INCLUDE NEW ACCESSIBLE FRONT ENTRANCE AT BASEMENT LEVEL, REGRADING,

LANDSCAPING, AND NEW DROP-OFF DRIVE AND WALKS AT FRONT LAWN, NEW 3-STOP

ELEVATOR AND ENCLOSURE.

BUILDING 4 CODE REVIEW

1. VA DIRECTORIES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE

ON THE TECHNICAL INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/)

2. INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2018

3. INTERNATIONAL BUILDING CODE (IBC) 2018 (ONLY PERTAINING TO ITEMS NOT ADDRESSED BY NFPA 101)

4. NFPA 101 LIFE SAFETY CODE 2018

5. INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2018; COMPLIANCE PATH: ASHRAE 90.1 - 2016

6. NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA 5000 AND NFPA 900

7. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS

8. VA SEISMIC DESIGN REQUIREMENTS, H-18-8

9. NATIONAL ELECTRICAL CODE (NEC) 2014

10. INTERNATIONAL PLUMBING CODE (IPC) 2015

11. ASME BOILER AND PRESSURE VESSEL CODE 2015

12. ASME CODE FOR PRESSURE PIPING

13. ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS) INCLUDING VA SUPPLEMENT,

14. BARRIER FREE DESIGN GUIDE (PG-18-13)

15. BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318)

16. INTERNATIONAL MECHANICAL CODE

APPLICABLE CODES

EGRESS REQUIREMENTS

AREA SEPARATION PROTECTION

SECTION IBC, 2018 SECTION NFPA 101, 2018

APPLICABLE CODE

(FOR BUSINESS OCCUPANCIES)

1- HR PARTITION

-OR-

AUTOMATIC SPRINKLER*

CONSTRUCTION DESCRIPTION RATING

FIXTURE REQUIREMENTS

SECTION IBC, 2018 SECTION NFPA 101, 2018

GROUND FLOOR PLAN: FACTOR OF 100 =

FIRST FLOOR PLAN: FACTOR OF 100 =

EXIT TRAVEL DISTANCE 300 FEET WITH

AUTOMATIC SPRINKLER

38.2.6.3 300 FEET WITH

AUTOMATIC SPRINKLER

CORRIDOR SEPARATION 0 HR. W/ SPRINKLERS

CORRIDOR WIDTH (MIN.)

44 INCH MINIMUM > 50 OCC

DEAD END CORRIDORS**: 50' W/ SPRINKLERS 50' W/ SPRINKLERS**

TABLE 1004.1.2

1020.4.2

TABLE 1020.1

TABLE 1018.2

141 (OCC. LOAD)

139 (OCC. LOAD)

106 (OCC. LOAD)

EMERGENCY EGRESS ILLUMINATION: AVERAGE OF 1.0 FOOT CANDLES AT EGRESS PATHS WITH A MIN. OF 0.1 CANDLE AT ANY POINT.

POWER SUPPLY: MEANS OF EGRESS ILLUMINATION NORMAL POWER IS TO BE PROVIDED BY PREMISE'S ELECTRICAL SYSTEM.

a. EGRESS ILLUMINATION: EITHER BATTERIES, SECOND PRIMARY SOURCE OR GENERATOR WITH A MIN. OF A 1 1/2 HOUR DURATION.

b. EXIT SIGNS: ILLUMINATED AT ALL TIME, EMERGENCY POWER REQ. WITH 1 1/2 HOUR DURATION.

38.2.3.2 and 7.3.4.1

(TABLE 2902.1)

LAVATORY DRINKING FOUNTAINS SERVICE SINK

1 PER 40 FOR FIRST 80,

THEN 1 PER 80

LEVEL

7.3.1.2.

148 (OCC. LOAD)

92 (OCC. LOAD)

71 (OCC. LOAD)

ELECTRICAL ROOM, WITH DRY TYPE

TRANSFORMER >112.5 kVA

NFPA 70

(NEC) 450-21

1-HOUR8.6.5 (3)

N/A

PROVIDED

APPROVED AUTOMATIC

SPRINKLER SYSTEM

1-HOUR

WATER CLOSET

BASEMENT FLOOR

FIRST FLOOR

1- HR PARTITION

-OR-

AUTOMATIC SPRINKLER*

STORAGE (INCIDENTAL USE)

WHERE DEGREE OF HAZARD IS

GREATER THAN GENERAL OCCUPANCY

1- HR PARTITION

-OR-

AUTOMATIC SPRINKLER*

APPROVED AUTOMATIC

SPRINKLER SYSTEM38.3.2.2NO REQUIREMENT

TABLE 1017.2

SECOND FLOOR PLAN: FACTOR OF 100 =

36 INCH MINIMUM < 50 OCC

44 INCH MINIMUM > 50 OCC

36 INCH MINIMUM < 50 OCC

COMMON PATH OF EGRESS TRAVEL: 100' W/ SPRINKLERS 100' W/ SPRINKLERSTABLE 1006.2.1

38.2.5.2

38.2.5.3.1

STAIR ENCLOSURE

713.6

2-HR >4 STORIES

1-HR <4 STORIES 7.1.3.2.1 (3)(b) 1 HR W/ SPRINKLER 2-HOUR

MINIMUM CEILING HEIGHT 7'-6" 7'-6" NEW (7'-0" EXISTING)1208.2 7.1.5.1 (1)

BUSINESS:

74 PERSONS +

74 PERSONS

OCCUPANT LOAD

REQ. PROVIDED*

BUSINESS:

92 PERSONS

SECOND FLOOR

BUSINESS:

71 PERSONS

REQ. PROVIDED*

1 PER 25 FOR FIRST 50,

THEN 1 PER 50

1 PER 100

REQ. PROVIDED*

2 2

REQ. PROVIDED

1 1

BUILDING DATA

ALLOWABLE AREA/FLOOR (SQ.FT.)

AUTOMATIC SPRINKLER INCREASE

ACTUAL AREA (BUILDING FOOTPRINT)

CONSTRUCTION TYPE

APPLICABLE CODE

3B

75' 48'

TABLE (601)

TABLE (506.2)

OCCUPANCY

NFPA 220

MAXIMUM ALLOWABLE HEIGHT

ACTUAL HEIGHT

BUSINESS: OUTPATIENT MENTAL HEALTH CLINIC

SECTION IBC, 2018 SECTION NFPA 101, 2018

TABLE (504.3)

57,000 SQ. FT.

14,900 SQ. FT.

75' 48'

TYPE III (200)

57,000 SF

15,570 SF

TERRA COTTA TILE +

FACEBRICK

REINFORCED POURED CONCRETE

RIBBED CONCRETE SLAB

WOOD FRAME

WOOD FRAMING

0-HOUR

2-HOURS

AUTHORITY HAVING JURISDICTION: VISN 4 SAFETY OFFICER

ALL WORK SHALL COMPLY WITH THE FOLLOWING CODES:

PROJECT TEAM

THE DEPARTMENT OF VETERANS AFFAIRS

COATESVILLE VAMC - VISN 4

1400 BLACKHORSE HILL ROAD

COATESVILLE, PENNSYLVANIA 19320

BANCROFT ARCHITECTS + ENGINEERS

700 NICHOLAS BLVD.

SUITE 300

ELK GROVE VILLAGE, IL 60007

P: 847-952-9362 www.bancroft-ae.com

BANCROFT ARCHITECTS + ENGINEERS

700 NICHOLAS BLVD.

SUITE 300

ELK GROVE VILLAGE, IL 60007

P: 847-952-9362

BANCROFT ARCHITECTS + ENGINEERS

700 NICHOLAS BLVD.

SUITE 300

ELK GROVE VILLAGE, IL 60007

P: 847-952-9362

BANCROFT ARCHITECTS + ENGINEERS

700 NICHOLAS BLVD.

SUITE 300

ELK GROVE VILLAGE, IL 60007

P: 847-952-9362

BANCROFT ARCHITECTS + ENGINEERS

700 NICHOLAS BLVD.

SUITE 300

ELK GROVE VILLAGE, IL 60007

P: 847-952-9362

BANCROFT ARCHITECTS + ENGINEERS

700 NICHOLAS BLVD.

SUITE 300

ELK GROVE VILLAGE, IL 60007

P: 847-952-9362

CIVIL ENGINEER

ARCHITECT

STRUCTURAL ENGINEER

FIRE PROTECTION ENGINEER

PLUMBING ENGINEER

MECHANICAL ENGINEER

ELECTRICAL ENGINEER

BANCROFT ARCHITECTS + ENGINEERS

700 NICHOLAS BLVD.

SUITE 300

ELK GROVE VILLAGE, IL 60007

P: 847-952-9362

OWNER

COST ESTIMATOR

INTERIORS

HAZARDOUS MATERIALS

6 1

FIRE EXTINGUISHER REQUIREMENTS (TABLE 6.2.1.1)

FIRE EXTINGUISHER REQUIREMENTS

NFPA 10:

HAZARD TYPE: TYPE A, ORDINARY HAZARD.

MAX FLOOR PER UNIT OF A: 1500SF

MAX TRAVEL TO EXTINGUISHER: 75'

SIZE AND RATING PROVIDED: 2A, 2.5 GAL

MIN. NO. OF EXTINGUISHERS REQUIRED / PROVIDED:

BASEMENT: 5 REQ / 5 PROVIDED

FIRST FLOOR: 5 REQ / 7 PROVIDED

SECOND FLOOR: 5 REQ / 7 PROVIDED

4 (EXISTING)

2 (EXISTING)

GROSS AREA: BASEMENT

FIRST FLOOR

SECOND FLOOR

14,030 GSF

13,818 GSF

10,560 GSF

3.3.22.2.1

NOTE: SEE GI101 FOR NFPA OCC. LOADS

JOHNSON WILBUR ADAMS INC.

STRUCTURAL ENGINEERING

33O S. NAPERVILLE ROAD

SUITE 300

WHEATON, ILLINOIS 60187

T:630.653.9060 F:630.653.9059 www.jwase.com

PENNTERRA ENGINEERING INC.

LANCASTER OFFICE:

COLUMBIA, PA 17512

P: 717-522-5031 www.pennterra.com

NUMBER TITLE DRAWN BY

FINAL

CONCEPT

DESIGN

50% MOD - 50% 100% FINAL

14 - ELECTRICAL

E001 ELECTRICAL GENERAL NOTES BAE • • • • •

E002 ELECTRICAL SYMBOLS AND ABBREVIATIONS BAE • • • • •

EPD100 ELECTRICAL POWER DEMO PLAN - BASEMENT BAE • • •

EPD101 ELECTRICAL POWER DEMO PLAN - FIRST FLOOR BAE • • • • •

EPD102 ELECTRICAL POWER DEMO PLAN - SECOND FLOOR BAE • • • • •

EPD103 ELECTRICAL HVAC POWER DEMO PLAN - ATTIC BAE • •

ELD100 ELECTRICAL LIGHTING DEMO PLAN - BASEMENT BAE • • •

ELD101 ELECTRICAL LIGHTING DEMO PLAN - FIRST FLOOR BAE • • • •

ELD102 ELECTRICAL LIGHTING DEMO PLAN - SECOND FLOOR BAE • • • •

ETD101 COMMUNICATION AND TECHNOLOGY DEMO PLAN - FIRST FLOOR BAE • • • •

ETD102 COMMUNICATION AND TECHNOLOGY DEMO PLAN - SECOND FLOOR BAE • • • •

EFD101 FIRE ALARM AND NURSE CALL DEMO PLAN - FIRST FLOOR BAE • • • •

EFD102 FIRE ALARM AND NURSE CALL DEMO PLAN - SECOND FLOOR BAE • • • •

ED501 EXISTING ELECTRICAL ONE-LINE DIAGRAM BAE • • • • •

ED802 COMMUNICATION AND TECHNOLOGY DEMOLITION RISER DIAGRAM BAE • •

EP100.1 ELECTRICAL POWER PLAN - BASEMENT - ZONE 1 BAE • • •

EP100.2 ELECTRICAL POWER PLAN - BASEMENT - ZONE 2 BAE • • •

EP100.3 ELECTRICAL POWER PLAN - BASEMENT - ZONE 3 BAE • • •

EP100.4 ELECTRICAL POWER PLAN - BASEMENT - ZONE 4 BAE • • •

EP100A ELECTRICAL HVAC POWER PLAN - BASEMENT BAE • •

EP101.1 ELECTRICAL POWER PLAN - FIRST FLOOR - ZONE 1 BAE • • • •

EP101.2 ELECTRICAL POWER PLAN - FIRST FLOOR - ZONE 2 BAE • • • •

EP101.3 ELECTRICAL POWER PLAN - FIRST FLOOR - ZONE 3 BAE • • • •

EP101.4 ELECTRICAL POWER PLAN - FIRST FLOOR - ZONE 4 BAE • • • •

EP101A ELECTRICAL HVAC POWER PLAN - FIRST FLOOR BAE • • • •

EP102.1 ELECTRICAL POWER PLAN - SECOND FLOOR - ZONE 1 BAE • • • •

EP102.2 ELECTRICAL POWER PLAN - SECOND FLOOR - ZONE 2 BAE • • • •

EP102.3 ELECTRICAL POWER PLAN - SECOND FLOOR - ZONE 3 BAE • • • •

EP102.4 ELECTRICAL POWER PLAN - SECOND FLOOR - ZONE 4 BAE • • • •

EP102A ELECTRICAL HVAC POWER PLAN - SECOND FLOOR BAE • • • •

EP103 ELECTRICAL HVAC POWER PLAN - ATTIC BAE • •

EL100 ELECTRICAL LIGHTING PLAN - BASEMENT BAE • • •

EL101.1 ELECTRICAL LIGHTING PLAN - FIRST FLOOR - ZONE 1 BAE • • • •

EL101.2 ELECTRICAL LIGHTING PLAN - FIRST FLOOR - ZONE 2 BAE • • • •

EL101.3 ELECTRICAL LIGHTING PLAN - FIRST FLOOR - ZONE 3 BAE • • • •

EL101.4 ELECTRICAL LIGHTING PLAN - FIRST FLOOR - ZONE 4 BAE • • • •

EL102.1 ELECTRICAL LIGHTING PLAN - SECOND FLOOR - ZONE 1 BAE • • • •

EL102.2 ELECTRICAL LIGHTING PLAN - SECOND FLOOR - ZONE 2 BAE • • • •

EL102.3 ELECTRICAL LIGHTING PLAN - SECOND FLOOR - ZONE 3 BAE • • • •

EL102.4 ELECTRICAL LIGHTING PLAN - SECOND FLOOR - ZONE 4 BAE • • • •

EL103 ELECTRICAL LIGHTING PLAN - ATTIC BAE •

ET100 COMMUNICATION AND TECHNOLOGY PLAN - BASEMENT BAE • •

ET101 COMMUNICATION AND TECHNOLOGY PLAN - FIRST FLOOR BAE • • • •

ET102 COMMUNICATION AND TECHNOLOGY PLAN - SECOND FLOOR BAE • • • •

EF100 ELECTRICAL FIRE ALARM AND SECURITY PLAN - BASEMENT BAE • •

EF101 ELECTRICAL FIRE ALARM AND SECURITY PLAN - FIRST FLOOR BAE • • • •

EF102 ELECTRICAL FIRE ALARM AND SECURITY PLAN - SECOND FLOOR BAE • • • •

EF103 ELECTRICAL FIRE ALARM AND SECURITY PLAN - ATTIC BAE • •

EN100 ELECTRICAL NURSE CALL PLAN - BASEMENT BAE • •

EN101 ELECTRICAL NURSE CALL PLAN - FIRST FLOOR BAE • • • •

EN102 ELECTRICAL NURSE CALL PLAN - SECOND FLOOR BAE • • • •

E501 ELECTRICAL ONE-LINE DIAGRAM BAE • • • •

E601 ELECTRICAL PANEL SCHEDULES BAE • • • •

E602 ELECTRICAL PANEL SCHEDULES BAE • • • •

E603 LIGHTING LIGHTING FIXTURE AND PANEL SCHEDULES BAE • • • •

E604 ELECTRICAL CABLE SCHEDULE BAE • •

E701 ELECTRICAL DETAILS BAE • • • •

E702 ELECTRICAL TYPICAL GROUNDING DETAILS BAE • •

T701 DATA DETAIL BAE • • • •

E801 COMMUNICATION AND TECHNOLOGY RISER DIAGRAM BAE • •

E802 ELECTRICAL LIGHTING CONTROL DIAGRAM - BASEMENT BAE • •

E803 ELECTRICAL LIGHTING CONTROL DIAGRAM - FIRST FLOOR BAE • •

E804 ELECTRICAL LIGHTING CONTROL DIAGRAM - SECOND FLOOR BAE • •

E805 ELECTRICAL FIRE ALARM RISER DIAGRAM BAE • •

E806 ELECTRICAL SECURITY RISER DIAGRAM BAE • •

INDEX SHEET CONTINUED

LANDSCAPE ARCHITECT

PENN TERRA

LANCASTER OFFICE:

COLUMBIA, PA 17512

P: 717-522-5031 www.pennterra.com

1SOURCE SAFETY AND HEALTH, INC.

140 SOUTH VILLAGE AVENUE

SUITE 130

EXTON, PA 19341

P: 888-873-9983

Revisions: Date:

FINAL CONCEPT DOCUMENTS SUBMISSION 15 JAN 2019

50% CONSTRUCTION DOCUMENTS SUBMISSION 16 APR 2019

MOD - 50% CONSTRUCTION DOCUMENTS SUBMISSION 21 JUN 2019

100% CONSTRUCTION DOCUMENTS SUBMISSION 3 JAN 2020

FINAL CONSTRUCTION DOCUMENTS SUBMISSION 31 JAN 2020

ADDENDUM 1 03 AUG 2020

File details come from the government source that posted it. Updated .