AE604 A0004.pdf
PDF 642 KB Posted
- Solicitation number
- 36C24125R0077Solicitation
About this file
This document is an architectural drawing set for partition types and floor-ceiling assemblies for the West Roxbury VA Medical Center in West Roxbury, Massachusetts. The project, numbered 0506-0012, involves replacing boilers and upgrading controls at the facility. The drawing is part of the bid documents issued for construction dated November 14, 2025, with an addendum issued on March 2, 2026. The drawing was prepared by WBRC INC Consultants as the engineer of record, with Mabbett & Associates serving as architect of record. Additional consultants include Koffel Associates for fire and life safety, GRW for electronic security, PEC for tunnel structural and civil engineering, and Force Protect for physical security.
The drawing details multiple wall and partition configurations including metal stud partitions (types M2, M4, M6, and M8 with stud sizes ranging from 2½ inches to 8 inches), concrete masonry unit (CMU) partitions (types C6, C8, C10, and C12 in various ratings), metal stud chase walls, and rated floor-ceiling assemblies. Construction specifications include 5/8-inch Type X gypsum wallboard application on metal studs at 16-inch spacing, mineral wool or unfaced sound attenuation blanket insulation for sound deadening, continuous acoustical or fire-stop sealants, and specific head and base conditions. The drawing also depicts rated assemblies complying with UL designs U906, U905, and U415, with fire-rating requirements ranging from 1-hour to 2-hour ratings. Deflection track attachments and acoustical putty coverage for electrical and telecommunications outlets are specified throughout the various partition types.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACH RUNNERS TO
FLOOR @ 24" O.C. AND
WITHIN 1" OF ENDS.
OUTLET BOX
CONTINUOUS
ACOUSTICAL SEALANT
EACH SIDE
SCHEDULED BASE
BASE CONDITION
PLAN CONDITION
ONE LAYER OF 5/8"
TYPE "X" GWB. ON
BOTH SIDES OF METAL
STUD @ 16" O.C. SEE
SCHEDULE FOR STUD
SIZES
MINERAL WOOL
INSULATION FRICTION
FIT FOR SOUND
DEADENING. FIT TO
FULL WIDTH OF CAVITY
COVER ALL SIDES OF ALL
TEL. & ELEC. OUTLETS WITH
1/4" THICK ACOUSTICAL
PUTTY BEFORE APPLYING
GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON
OPP. SIDES OF PARTITIONS.
HEAD CONDITION
WALL TYPE VA PARTITION # STUD SIZE
METAL STUD WALL STUD SIZE SCHEDULE
M2 09P22M2 2 1/2"
M6 09P62M6 6"
M8 09P82M8 8"
M4 09P42M4 3 5/8"
AE604
B5
Sim
1/
2"
8" NOM CMU BLOCK
GYPSUM WALL
BOARD CEILING
SHOWN SEE CEILING
PLANS FOR
LOCATION AND
HEIGHTS
ATC CEILING
SHOWN (SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS)
GYPSUM WALLBOARD
CEILING SYSTEM SEE
SPEC
UNDERSIDE OF METAL
DECKING OR
UNDERSIDE OF ROOF
SHEATHING
SLUSH CELLS 4"
DEEP MIN W/ GROUT
CONTINUOUS
ACOUSTICAL TAPE
AND SEALANT
WALL TYPE CMU SIZE
WALL CMU SIZE SCHEDULE
C6 6"
C10 10"
C12 12"
C8 8"
8" NOM CMU BLOCK
GYPSUM WALL
BOARD CEILING
SHOWN SEE CEILING
PLANS FOR
LOCATION AND
HEIGHTS
ATC CEILING SHOWN
(SEE CEILING PLANS
FOR LOCATION AND
HEIGHTS)
GYPSUM WALLBOARD
CEILING SYSTEM SEE
SPEC
UNDERSIDE OF METAL
DECKING OR
UNDERSIDE OF ROOF
SHEATHING
1/
2"
SLUSH CELLS 4"
DEEP MIN W/ GROUT
CONTINUOUS
ACOUSTICAL TAPE
AND SEALANT
WALL TYPE CMU SIZE
WALL CMU SIZE SCHEDULE
C6.1 6"
C10.1 10"
C12.1 12"
C8.1 8"
8" NOM CMU
BLOCK (CLASS
D-2)
1/
2"
GYPSUM WALL
BOARD CEILING
SHOWN SEE CEILING
PLANS FOR
LOCATION AND
HEIGHTS
ATC CEILING SHOWN
(SEE CEILING PLANS
FOR LOCATION AND
HEIGHTS)
GYPSUM WALLBOARD
CEILING SYSTEM SEE
SPEC
UNDERSIDE OF
METAL DECKING OR
UNDERSIDE OF ROOF
SHEATHINGSLUSH CELLS 4"
DEEP MIN W/ GROUT
CONTINUOUS
ACOUSTICAL TAPE
AND SEALANT
WALL TYPE CMU SIZE
WALL CMU SIZE SCHEDULE
C6.2 6"
C10.2 10"
C12.2 12"
C8.2 8"
UNDERSIDE OF
CONCRETE
PLANK
SLUSH CELLS
4" DEEP MIN
w/ GROUT
CONTINUOUS
ACOUSTICAL TAPE
AND SEALANT
UL DESIGN: U906
SEE STRUCTURAL
FOR ATTACHMENT
ATTACH DEEP LEG
DEFLECTION TRACK TO
STRUCTURE AT 24" O.C.
AND WITHIN 1" OF END
HEAD CONDITION
PERPENDICULAR TO DECK
ONE LAYER OF 5/8" TYPE
"X" GWB ON BOTH SIDES
OF DEFLECTION TRACK
CONTINUOUS ACOUSTICAL
JOINT SEALANT
COPE GWB INTO FLUTES
OF DECKING AND
AROUND BEAMS,
BRIDGING, PIPING, ETC...
ATTACH DEEP LEG
DEFLECTION TRACK TO
STRUCTURE AT 24" O.C.
AND WITHIN 1" OF END
HEAD CONDITION
PARALLEL TO DECK
ONE LAYER OF 5/8" TYPE
"X" GWB ON BOTH SIDES
OF DEFLECTION TRACK
CONTINUOUS ACOUSTICAL
JOINT SEALANT
PROVIDE "Z"-CLIP
AS REQUIRED FOR
DEFLECTION TRACK
ATTACHMENT
UNFACED SOUND
ATTENUATION BLANKET
INSULATION. FRICTION FIT
FOR SOUND DEADENING.
UNFACED SOUND
ATTENUATION BLANKET
INSULATION. FRICTION FIT
FOR SOUND DEADENING.
TOP OF METAL DECK
MINERAL WOOL IN
DECK FLUTES, TYP.
BOTTOM OF MTL. DECK
FIRE-RATED GYPSUM
COMPOUND OR FIRE CAULK
CONTINUOUS ON BOTH SIDES
FIRE TRAK
POSI - CLIPS
5/8" TYPE "X" GWB
CUT TO FIT DECK
FLUTES
METAL STUD
1/
2" 2"
8"
3"
HEAD CONDITION
PARALLEL TO DECK
PROVIDE "Z"-CLIP
AS REQUIRED FOR
DEFLECTION TRACK
ATTACHMENT
TOP OF METAL DECK
FIRE-RATED GYPSUM
COMPOUND OR FIRE CAULK
CONTINUOUS ON BOTH
SIDES
FIRE TRAK
POSI - CLIPS
5/8" TYPE "X" GWB
TO B.O. DECK
METAL STUD
1/
2" 2"
8"
3"
HEAD CONDITION
PERPENDICULAR TO DECK
METAL DECK
SEE STRUC DRAWINGS
3-1/4" LIGHTWEIGHT
CONCRETE SLAB
SEE STRUC DRAWINGS
WELDED WIRE FABRIC
6x6 - W1.4xW1.4
UL DESIGN: D916 AT 1HR & 2HR FLOOR/CEILING ASSEMBLIES
5"
ATTACH J RUNNERS TO
FLOOR @ 24" O.C. AND
WITHIN 1" OF ENDS.
ATTACH J RUNNER
TRACK TO STRUCTURE
AT 24" O.C. AND WITHIN
1" OF END
ONE LAYER OF 5/8"
TYPE "X" GWB. ON
FACE SIDE AND 1"
TYPE "X" GWB ON
BACK SIDE OF 2 1/2"
METAL CT STUD @ 16"
O.C.
CONTINUOUS FIRE
STOP SEALANT
SCHEDULED FLOOR
SCHEDULED BASE
BASE CONDITION
PLAN CONDITION
HEAD CONDITION
SEAL WALL TO
DECKING WITH
CONTINUOUS FIRE
STOP SEALANT; BOTH
SIDES
UL DESIGN: U415
ATTACH RUNNERS TO
FLOOR @ 24" O.C. AND
WITHIN 1" OF ENDS.
OUTLET BOX
CONTINUOUS
FIRESTOP SEALANT
EACH SIDE
SCHEDULED BASE
BASE CONDITION
PLAN CONDITION
ONE LAYER OF 5/8"
TYPE "X" GWB. ON
BOTH SIDES OF METAL
STUD @ 16" O.C. SEE
SCHEDULE FOR STUD
SIZES
UNFACED MINERAL
WOOL BLANKET
INSULATION FRICTION
FIT FOR SOUND
DEADENING. FIT TO
FULL WIDTH OF CAVITY
COVER ALL SIDES OF ALL
TEL. & ELEC. OUTLETS WITH
1/4" THICK ACOUSTICAL
PUTTY BEFORE APPLYING
GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON
OPP. SIDES OF PARTITIONS.
HEAD CONDITION
WALL TYPE VA PARTITION # STUD SIZE
METAL STUD WALL STUD SIZE SCHEDULE
M2.1 09P22M2 2 1/2"
M6.1 09P62M6 6"
M4.1 09P42M4 3 5/8"
AE604
B7
Sim
ATTACH RUNNERS TO
FLOOR @ 24" O.C. AND
WITHIN 1" OF ENDS.
OUTLET BOX
CONTINUOUS
ACOUSTICAL SEALANT
EACH SIDE
SCHEDULED BASE
BASE CONDITION
PLAN CONDITION
ONE LAYER OF 5/8"
TYPE "X" GWB. ON ONE
SIDE OF METAL STUD
@ 16" O.C. SEE
SCHEDULE FOR STUD
SIZES
MINERAL WOOL
INSULATION FRICTION
FIT FOR SOUND
DEADENING. FIT TO
FULL WIDTH OF CAVITY
COVER ALL SIDES OF ALL
TEL. & ELEC. OUTLETS WITH
1/4" THICK ACOUSTICAL
PUTTY BEFORE APPLYING
GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON
OPP. SIDES OF PARTITIONS.
HEAD CONDITION
WALL TYPE STUD SIZE
METAL STUD WALL STUD
SIZE SCHEDULE
M2C 2 1/2"
M6C 6"
M8C 8"
M4C 3 5/8"
CONTINUOUS
ACOUSTICAL SEALANT
ATTACH DEEP LEG
DEFLECTION TRACK TO
STRUCTURE AT 24" O.C.
AND WITHIN 1" OF END
ATTACH RUNNERS TO
FLOOR @ 24" O.C. AND
WITHIN 1" OF ENDS.
OUTLET BOX
CONTINUOUS
ACOUSTICAL SEALANT
EACH SIDE
SCHEDULED BASE
BASE CONDITION
PLAN CONDITION
(2) LAYERS OF 5/8"
TYPE "X" GWB. ON ONE
SIDE OF METAL STUD
@ 16" O.C. SEE
SCHEDULE FOR STUD
SIZES
MINERAL WOOL
INSULATION FRICTION
FIT FOR SOUND
DEADENING. FIT TO
FULL WIDTH OF CAVITY
COVER ALL SIDES OF ALL
TEL. & ELEC. OUTLETS WITH
1/4" THICK ACOUSTICAL
PUTTY BEFORE APPLYING
GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON
OPP. SIDES OF PARTITIONS.
HEAD CONDITION
WALL TYPE STUD SIZE
METAL STUD WALL STUD
SIZE SCHEDULE
M4C.1 3 5/8"
CONTINUOUS
ACOUSTICAL SEALANT
ATTACH DEEP LEG
DEFLECTION TRACK TO
STRUCTURE AT 24" O.C.
AND WITHIN 1" OF END
ATTACH RUNNERS TO
FLOOR @ 24" O.C. AND
WITHIN 1" OF ENDS.
OUTLET BOX
CONTINUOUS
FIRESTOP SEALANT
EACH SIDE
SCHEDULED BASE
BASE CONDITION
PLAN CONDITION
ONE LAYER OF 5/8"
TYPE "X" GWB. ON
BOTH SIDES OF METAL
STUD @ 16" O.C. SEE
SCHEDULE FOR STUD
SIZES
UNFACED MINERAL
WOOL BLANKET
INSULATION FRICTION
FIT FOR SOUND
DEADENING. FIT TO
FULL WIDTH OF CAVITY
COVER ALL SIDES OF ALL
TEL. & ELEC. OUTLETS WITH
1/4" THICK ACOUSTICAL
PUTTY BEFORE APPLYING
GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON
OPP. SIDES OF PARTITIONS.
HEAD CONDITION
WALL TYPE STUD SIZE
METAL STUD WALL
STUD SIZE SCHEDULE
M2.2 2 1/2"
M6.2 6"
M4.2 3 5/8"
AE604
B7
Sim
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseENGINEER OF RECORD WBRC INC
ARCHITECT OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE ARCHITECT OF RECORD
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h o n e fo o t th re e in c h o n e fo o t
523A4-20-208
MR PROJECT NO:
Hazardous Materials:
MABBETT & ASSOCIATES
Architect & Civil Engineering:
WBRC
Fire & Life Safety:
KOFFEL ASSOCIATES
Electronic Security:
GRW
Tunnel Structural & Civil Engineering:
PEC
Physical Security:
FORCE PROTECT
2/
/2
3:
:5
PM
AE604
ARCHITECTURAL
PARTITION TYPES & FLOOR CEILING ASSEMBLY
REPLACE BOILERS AND
UPGRADE CONTROLS
WEST ROXBURY VA MEDICAL CENTER
WEST ROXBURY, MA
11/14/2025 TRJ BRS
BID DOCUMENTS
ISSUED FOR CONSTRUCTION
0506-0012
3" = 1'-0"
F8 M# - METAL STUD PARTITIONS
3/4" = 1'-0"
D9 C# - NOM CMU PARTITION
3/4" = 1'-0"
D7 C#.1 - NOM CMU RATED 1 HOUR- U.L. #U906
3/4" = 1'-0"
D5 C#.2 - NOM CMU 2 HOUR- U.L. #U905
3" = 1'-0"
D1 TYPICAL HEAD CONDITION - CMU
3" = 1'-0"
B5 EXPOSED T.O. WALL TO B.O. DECK
HEAD CONDITIONS 3" = 1'-0"
B7 T.O. MTL. STUD - 1-HR - 3" DEFLECTION
3" = 1'-0"
B2 RATED FLOOR/CEILING ASSEMBLY DETAIL
3" = 1'-0"
F1 CH2.1 - 2 1/2" CH STUD SHAFTWALL - 1HR
NO. DESCRIPTION DATE
1 ADDENDUM 01 03/02/2026
3" = 1'-0"
F5 M#.1 - METAL STUD PARTITIONS - 1HR - U.L. #419
3" = 1'-0"
F3 M# - METAL STUD CHASE
3" = 1'-0"
D3 M#C.1 - METAL STUD CHASE - 1HR
1 1
3" = 1'-0"
B3 M#.2 - METAL STUD PARTITIONS - 2HR - U.L. #419
3/3/2026
File details come from the government source that posted it. Updated .