AE103_3 A0004.pdf
PDF 668 KB Posted
- Solicitation number
- 36C24125R0077Solicitation
About this file
This document is an architectural floor plan drawing for a federal construction project at the West Roxbury VA Medical Center in West Roxbury, Massachusetts. The drawing, dated November 14, 2025, with Addendum 01 issued March 2, 2026, depicts the Upper Mezzanine level of the Boiler Plant and Electrical Spaces for Phase 3 of the project titled "Replace Boilers and Upgrade Controls." The project number is 0506-0012, and the drawing number is AE103.3. The plan identifies key spaces including a boiler room below, generator room below, and storage areas (rooms 301 and 320-321), along with mechanical systems such as a piping bridge referenced to MEP and structural drawings. The document is issued for construction bidding and includes phasing information indicating this represents Phase 3 work.
The drawing was prepared by WBRC Architects and Civil Engineers as the Architect of Record, with WBRC Inc. Consultants as the Engineer of Record. Additional consultants include Mabbett & Associates (Hazardous Materials), Koffel Associates (Fire & Life Safety), GRW (Electronic Security), PEC (Tunnel Structural & Civil Engineering), and Force Protect (Physical Security). The scale used is 1/8" = 1'-0", and the document includes a key plan, north orientation, and detailed dimensional annotations. This bid document was issued for construction on March 3, 2026, and is under the jurisdiction of the U.S. Department of Veterans Affairs, Office of Construction and Facilities Management.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
F
F
DN
UP
BOILER ROOM
BELOW
AE201.3
B1
AE201.3D1
AE201.3
F1
F1
AE301.3
F4
AE301.3
C1
AE301.3
C4
AE301.3
AE201.3D5
GENERATOR
ROOM BELOW
STORAGE
STAIR
STAIR
F
PIPING BRIDGE. SEE MEP AND
STRUCTURAL DRAWINGS
A
C
D
B.3
B
A.4
C.9
A.6
E
A.7
8'
6" 7'
4"
9"
6'
6'
1" 8'
3/ 8"
2'
5/
8"
5'
0"
5' - 0" 6' - 0" 18' - 8" 6' - 0" 12' - 0" 6' - 0" 12' - 0" 6' - 0" 35' - 0" 6' - 0" 7' - 4" 6' - 0" 7' - 4" 6' - 0" 5' - 11 1/4"
E E E E E E E E
AE503
B1
AE503
B4
R.O.
3' - 4" 1' - 4" R .O
3'
4" 3'
4"
B9
AE502
17' - 0" 13' - 10 1/2" 27' - 0" 14' - 2 1/2" 11' - 5" 8' - 10" 5' - 0" 7' - 6" 7' - 6" 10' - 6" 18' - 0" 18' - 0" 25' - 3" 13' - 6" 13' - 6" 13' - 6"
F9
X6 X4 9 8 7 6 5 4 13 2X2 X1X5 7.68.48.7X3
5'-0" SECTION OF
REMOVABLE GUARD
RAIL FOR SCISSOR
LIFT ACCESS.
SEE STRUCTURAL
DWGS FOR DETAILS
M6.2
E1
E2
E2
E2E1
C12
C12.1
C8.2
E1
APPLY FULLY ADHERED,
PERMEABLE, AIR AND
MOISTURE BUILDING
ENVELOPE PROTECTION
MEMBRANE TO EXPOSED
CMU WALL
EXISTING TO REMAIN
DRAWING PHASING LEGEND:
PHASE 3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseENGINEER OF RECORD WBRC INC
ARCHITECT OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE ARCHITECT OF RECORD
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h o n e fo o t th re e in c h o n e fo o t
523A4-20-208
PLAN
NORTH
KEYPLAN
ACTUAL
NORTH
AREA A AREA B
MR PROJECT NO:
Hazardous Materials:
MABBETT & ASSOCIATES
Architect & Civil Engineering:
WBRC
Fire & Life Safety:
KOFFEL ASSOCIATES
Electronic Security:
GRW
Tunnel Structural & Civil Engineering:
PEC
TUNNEL
BLDG 1
Physical Security:
FORCE PROTECT
2/
/2
3:
:4
PM
AE103.3
ARCHITECTURAL
BOILER PLANT & ELEC SPACES
UPPER MEZZANINE - PHASE 3
REPLACE BOILERS AND
UPGRADE CONTROLS
WEST ROXBURY VA MEDICAL CENTER
WEST ROXBURY, MA
11/14/2025 TRJ BRS
BID DOCUMENTS
ISSUED FOR CONSTRUCTION
0506-0012
1/8" = 1'-0"
F1 BOILER PLANT & ELEC SPACES MEZZANINE LEVEL
3 - FLOOR PLAN
NO. DESCRIPTION DATE
1 ADDENDUM 01 03/02/2026
3/3/2026
File details come from the government source that posted it. Updated .