The document is a DD Form 1354 Checklist, a comprehensive inventory and tracking document for facility and equipment details. The checklist provides exhaustive documentation of building specifications, utility connections, installed real property, building systems, and specialized facilities across multiple categories including fire protection, security, heating, air conditioning, electrical systems, and related infrastructure. The form meticulously catalogs items such as building dimensions, construction materials, utility connections, installed equipment, and potential recyclable materials, with detailed sections for both added and removed property components.

The checklist is specifically designed to record granular information about facility assets, with sections broken down into categories like building systems (fire protection, security, heating), installed equipment (water heaters, elevators, utility sinks), related facilities (transformers, power lines, sewage systems), and specialized facilities including shops, chapels, theaters, billeting buildings, MWR buildings, and post office spaces. Each section provides spaces to document quantity, unit of measure, cost, serial numbers, and other critical identifying and tracking information, enabling comprehensive real property and equipment management.

View the file

Other files

File Type Posted
WWYK090020_Pre-Bid RFI Responses COR.pdf PDF
WWYK090020 - Initial Site Visit Sheet.pdf PDF
Solicitation - FA813725R0038 for WWYK090020.pdf PDF
2020 TAFB Facility Standard.pdf PDF
2023 TAFB Fire Protection Standard.pdf PDF
dafi13-213.pdf PDF
013300_Attch1_TAFBF3000.pdf PDF
8_090020_SOW.pdf PDF
860072.pdf PDF
2020 TAFB Mechanical Standard.pdf PDF
2024 TAFB Electrical Standards.pdf PDF
00 71 00.pdf PDF
01 78 00.pdf PDF
01 32 16.00 20.pdf PDF
00 80 05.pdf PDF
00 80 00.pdf PDF
UMRL.pdf PDF
ufc_3_600_01_2016_c6.pdf PDF
afi91-202_afmcsup.pdf PDF
tinkerafbi13-204.pdf PDF
dafi91-202.pdf PDF
afman32-7003.pdf PDF
afman40-201.pdf PDF
tinkerafb_INRMP_App E.pdf PDF
007200_Attch13_AF487.pdf PDF
9_090020_Submittal Register_final.pdf PDF
20030059.pdf PDF
01 33 00.pdf PDF
01 42 00.pdf PDF
01 78 23.pdf PDF
000_TABLE OF CONTENTS.pdf PDF
ERDCITL_TR12-1_r2.pdf PDF
ERDCITL_TR12-6_r6.pdf PDF
ufc_3_260_01_2019_c1.pdf PDF
dafman91-203.pdf PDF
dafi21-101.pdf PDF
ufc_3_601_02_2021.pdf PDF
afman48-148.pdf PDF
dafi13-213_tinkerafbsup.pdf PDF
afman91-203_oc-alcsup.pdf PDF
dodio-2000.16v1_afi10-245-o.pdf PDF
afi48-104.pdf PDF
WWYK090020 EAL List - BLANK.xlsx XLSX spreadsheet
910243W.pdf PDF
00 72 00.pdf PDF
00 70 00.pdf PDF
01 50 00.pdf PDF
01 33 16.00 10.pdf PDF
01 45 00.00 10.pdf PDF
tinkerafb_INRMP.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DD Form 1354 Checklist

Facility Number

Building Name

Number of Floors

Gross SF

Net SF

1. Building Dimensions and Construction Material

Building Outside Dimensions

Length (LF)

Width (LF)

Main Building

Wings

Offsets

Basement

Attic

Porches, Covered

Roof

Foundation

Other Building Data

Feet

Ceiling Height Main Bldg

Ceiling Height Basement

Door Height

Door With

Code

Fire Rating Code

Construction Materials

Type

Principal Struct Material

Secondary Struct Material

Exterior Wall Material

Interior Wall Material

Floor Surface Material

Sub-Floor Material

Construction Materials (Pavements)

Type

Surface Course Materials

Base Course Materials

2. Utility Connection, Information, and Fuel Data:

Utility Connections

Number of Pipes

Diameter of Each Pipe

Capacity of All Inlet Pipes

Available or Connected? (Yes / No)

Water

Gas

Sewer Pipe

Storm Sewer Pipe

Steam

Condensate

Comm.

System

Energy Type

Source Location

Fuel Description

Air Circulation

Heating

Air Conditioning

Hot Water

Steam

Electric

Electric

Phase/ Voltage

Wire Size

Connected Load – Amps

Connected Load - KVA

3. Installed Real Property

a. Building Systems:

(1) Fire Protection System:

Category Code

Nomenclature Unit of Measure

Qty

Cost

Serial Number / Description

Closed Head Auto Sprinklers
SF

HD

Open Head Deluge System
SF

HD

Auto Fire Detection System
SF

EA

Manual Fire Alarm System
EA
CO2 Fire System
EA
Foam Fire System
EA
Other Fire System
EA
Halon 1301 Fire System
EA

(2) Security System:

Category Code

Nomenclature Unit of

Serial Number /

Security Alarm System
EA

(3) Heating System:

Category Code

Nomenclature Unit of

Serial Number /

Heating Plant 750/3500 MB
MB
Heating Plant Over 3500 MB
MB

Storage Tank for Heating Or Generator Fuel

GA

TYPE
NA

NA

FUEL
NA

NA

(4) Air Conditioning System:

Category Code

Nomenclature Unit of

Serial Number /

A/C Window Units
TN

SF

A/C Plant Less than 5 TN
TN

SF

A/C Plant 5 to 25 TN
TN
A/C Plant 25 to 100 TN
TN
A/C Plant Over 100 TN
TN

(5) Electrical System:

Category Code

Nomenclature Unit of

Serial Number /

Electric Emergency Power Generator
KW
Storage Tank for Heating or Generator Fuel
GA
TYPE
NA

NA

FUEL
NA

NA

b. Real Property Installed Equipment:

Item

Unit of

Qty

Model

Serial Number /

Evaporative Coolers
CFM
Hot Water Heater
GA
Exhaust Fan
CFM
Wash Basin
EA
Water Closet
EA
Urinal
EA
Utility Sink
EA
Refrigerated Drinking Fountain
EA
Heating Plant under 750 MB
MB
Forced Air Heating
BTU
Other Heating
BTU
Dehumidifiers
GPM
Elevators
Lbs

PN

Theater-Type Seats Secured To Floor
EA

Other

c. Related Facilities Added:

Category Code

Nomenclature Unit of

Serial Number /

Prim Distr Line OH
LF
Transformers
KVA
Power Poles
LF
Sec Distr Line OH
LF
Prim Distr Line UG
LF
Sec Distr Line UG
LF

Exterior Street Lighting or Parking Area Lights

EA

Gas Mains
LF
Sewage Septic Tank
KG
Sanitary Sewer
LF
Water Distr Mains
LF
Fire Hydrants
EA
Curbs & Gutters
LF
Driveway
SY
Road
SY

LF

Vehicle Parking
SY
Storm Drain
LF
Fence, Security
LF
Fence, Interior
LF
Sidewalk
SY

Utility Vault (4 or more transformers)

SF

Tel Duct Facility
LF
Tel Pole Facility
LF

d. Specialized Facilities/RPIE Added:

(1) Shops:

Category Code

Nomenclature Unit of

Amount

Serial Number

Air Compressors
HP
Hoists, Cranes (fixed)
TN
Hydraulic Lifts
TN
Emergency Shower
EA
Fixed Spray Paint Booth
EA
Load and Unload Platform
SF
Industrial Waste Main
LF
Compressed Air Dist
LF

(2) Chapel:

Category Code

Nomenclature Unit of

Serial Number

Pews
EA
Altars
EA
Lecterns
EA
Pulpit
EA

(3) Theater:

Category Code

Nomenclature Unit of

Serial Number

Theater Seats Secured to Floor

EA

Fire Screens
EA

(4) Billeting Buildings:

Category Code

Nomenclature Unit of

Serial Number

Built-in Household Dishwasher

EA

Garbage Disposals
EA

Built-in Domestic Ranges and Ovens

EA

Range Canopy w/Exhaust Fan
EA

Water Softener, Household Type

EA

(5) MWR Buildings:

Category Code

Nomenclature Unit of

Serial Number

Dishwashers, Built-in
EA

Walk-in Refrigerators Built-in

EA

Garbage Disposal Unit
EA

Range Canopy w/ Exhaust Canopy System

EA

PA System, Built-in
EA
Vault, Built-in
EA
Stage and Auditorium
SF
Playground Equipment Permanently Affixed
EA
Bowling Alley Lanes,
LA

Approaches, Ball Returns Load & Unload Platforms

SF

(6) Post Office:

Category Code

Nomenclature Unit of

Serial Number

Post office lock boxes
EA

(7) List any other items installed, but not listed above. Please indicate size, square footage, amount, number of units, etc. as applicable.

4. Removed Real Property

a. Building Systems:

(1) Fire Protection System:

Category Code

Nomenclature Unit of

Serial Number /

Closed Head Auto Sprinklers
SF

HD

Open Head Deluge System
SF

HD

Auto Fire Detection System
SF

EA

Manual Fire Alarm System
EA
CO2 Fire System
EA
Foam Fire System
EA
Other Fire System
EA
Halon 1301 Fire System
EA

(2) Security System:

Category Code

Nomenclature Unit of

Serial Number /

Security Alarm System
EA

(3) Heating System:

Category Code

Nomenclature Unit of

Serial Number /

Heating Plant 750/3500 MB
MB
Heating Plant Over 3500 MB
MB

Storage Tank for Heating Or Generator Fuel

GA

TYPE
NA

NA

FUEL
NA

NA

(4) Air Conditioning System:

Category Code

Nomenclature Unit of

Serial Number /

A/C Window Units
TN

SF

A/C Plant Less than 5 TN
TN

SF

A/C Plant 5 to 25 TN
TN
A/C Plant 25 to 100 TN
TN
A/C Plant Over 100 TN
TN

(5) Electrical System:

Category Code

Nomenclature Unit of

Serial Number /

Electric Emergency Power Generator
KW
Storage Tank for Heating or Generator Fuel
GA
TYPE
NA

NA

FUEL
NA

NA

b. Real Property Installed Equipment:

Item

Unit of

Qty

Model

Serial Number /

Evaporative Coolers
CFM
Hot Water Heater
GA
Exhaust Fan
CFM
Wash Basin
EA
Water Closet
EA
Urinal
EA
Utility Sink
EA
Refrigerated Drinking Fountain
EA
Heating Plant under 750 MB
MB
Forced Air Heating
BTU
Other Heating
BTU
Dehumidifiers
GPM
Elevators
Lbs

PN

Theater-Type Seats Secured To Floor
EA

Other

c. Related Facilities Removed:

Category Code

Nomenclature Unit of

Serial Number /

Prim Distr Line OH
LF
Transformers
KVA
Power Poles
LF
Sec Distr Line OH
LF
Prim Distr Line UG
LF
Sec Distr Line UG
LF

Exterior Street Lighting or Parking Area Lights

EA

Gas Mains
LF
Sewage Septic Tank
KG
Sanitary Sewer
LF
Water Distr Mains
LF
Fire Hydrants
EA
Curbs & Gutters
LF
Driveway
SY
Road
SY

LF

Vehicle Parking
SY
Storm Drain
LF
Fence, Security
LF
Fence, Interior
LF
Sidewalk
SY

Utility Vault (4 or more transformers)

SF

Tel Duct Facility
LF
Tel Pole Facility
LF

d. Specialized Facilities/RPIE Removed:

(1) Shops:

Category Code

Nomenclature Unit of

Serial Number

Air Compressors
HP
Hoists, Cranes (fixed)
TN
Hydraulic Lifts
TN
Emergency Shower
EA
Fixed Spray Paint Booth
EA
Load and Unload Platform
SF
Industrial Waste Main
LF
Compressed Air Dist
LF

(2) Chapel:

Category Code

Nomenclature Unit of

Serial Number

Pews
EA
Altars
EA
Lecterns
EA
Pulpit
EA

(3) Theater:

Category Code

Nomenclature Unit of

Serial Number

Theater Seats Secured to Floor

EA

Fire Screens
EA

(4) Billeting Buildings:

Category Code

Nomenclature Unit of

Serial Number

Built-in Household Dishwasher

EA

Garbage Disposals
EA

Built-in Domestic Ranges and Ovens

EA

Range Canopy w/Exhaust Fan
EA

Water Softener, Household Type

EA

(5) MWR Buildings:

Category Code

Nomenclature Unit of

Serial Number

Dishwashers, Built-in
EA

Walk-in Refrigerators Built-in

EA

Garbage Disposal Unit
EA

Range Canopy w/ Exhaust Canopy System

EA

PA System, Built-in
EA
Vault, Built-in
EA
Stage and Auditorium
SF
Playground Equipment Permanently Affixed
EA
Bowling Alley Lanes,
LA

Approaches, Ball Returns Load & Unload Platforms

SF

(6) Post Office:

Category Code

Nomenclature Unit of

Serial Number

Post office lock boxes
EA

(7) List any other items removed, but not listed above. Please indicate size, square footage, amount, number of units, etc. as applicable.

e. List products and materials that can be recovered and remanufactured into a new product. Recyclable materials include, but are not limited to, the following:

(1)Metals (ferrous and non-ferrous), including banding, metal studs, ductwork and piping.
(2)Asphaltic concrete paving
(3)Portland cement concrete
(4)Land clearing debris including trees and plant materials
(5)Native rock and granular fill
(6)Gypsum products
(7)Paper and cardboard
(8)Wood products, including structural, finish, crates and pallets
(9)Brick and masonry
(10)Plastics
(11)Copper wiring
(12)Mechanical and electrical products and equipment

These recyclable products shall be reported by weight to the Contracting Officer.