Z2AA - Renovate Historic Building 4

Closed Solicitation Posted

Solicitation number
36C24624R0030
Agency
Veterans Integrated Service Network 6 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
236220 Commercial and Institutional Building Construction
PSC
Z2AA Repair Or Alteration Of Office Buildings
Place of performance
Fayetteville, North Carolina 28301, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6 is procuring comprehensive renovation services for Historic Building 4 at the Fayetteville VA Medical Center in North Carolina. This project involves a complete renovation of the existing historic building to provide administrative space and offices, including the addition of an elevator with access to all levels, code-compliant stairwells for life safety egress, and modernization of all mechanical, plumbing, electrical, and fire protection systems. The renovation must comply with VA Physical Security and Resiliency Design Manual requirements for Mission Critical structures and National and State Historic Preservation Office requirements for exterior work. The procurement uses a Best Value Tradeoff evaluation approach with technical factors significantly more important than price, evaluating technical approach, management plan, key personnel qualifications, and past performance. The original proposal due date was February 10, 2025, but Riley Contracting Group, Inc. was awarded the contract on June 11, 2025.

This contract opportunity was designated as a 100% Service-Disabled Veteran-Owned Small Business set-aside with an estimated value range of $5-10 million. Riley Contracting Group, Inc. was ultimately awarded contract 36C24625C0027 for $10,854,777.58 following the competitive bidding process. The project requires a 450-day completion timeline from Notice to Proceed and includes significant hazardous material remediation, specifically asbestos and lead abatement based on comprehensive surveys identifying extensive contamination throughout the approximately 14,000-square-foot building. The work must be performed at the Fayetteville VA Medical Center campus at 2300 Ramsey Street, Fayetteville, NC 28301, with the contractor required to maintain pedestrian and vehicle traffic flow during construction while implementing detailed mobilization and safety plans.

Notice text

This project consists of a complete renovation of the existing Historic Building 4 for administrative space and offices along with necessary support and utility requirements. This is designated as Mission Critical and must comply with VA Physical Security and Resiliency Design Manual (PSRDM) requirements for Mission Critical structures as incorporated in this design and the specifications.  The project provides an addition for an elevator with access to all levels, and addresses life safety egress issues with the addition of code-compliant stairwells. Exterior renovations of the historical building will be renovated per National and State Historic Preservation Office (SHPO) requirements outlined in the specifications and drawings.  The project will modernize the space with the most current level of technology and design including all new mechanical, plumbing, electrical, and fire protections systems.  This design was created using Revit and Building Information Modeling (BIM) and all efforts post construction award shall be required to use Revit level of detail (LOD) 300 or higher.  The Revit drawings will only be made available to the contractor awarded this project.

This project does require asbestos and lead abatement.

There are underground existing utilities and installations this contactor shall relocate.

There is mobilization and project area located at the building, but pedestrian and vehicle traffic ways must be kept open for facility use.  Any additional space required may be remote on the facility or the contractor shall have to find a location off station but will not be compensated by the VA.

See specification section 01 35 26 Safety Requirements for detailed requirements of the Site Superintendent, SSHO, and Quality Control Manager.

The contractor shall provide a mobilization plan along with all other required plans prior to being allowed on this station.  MOB plan shall address all temporary utility measures, fence/gates, contractor parking, temporary signage/project signage, materials storage, dumpsters and any other details as requested by the VA COR.

Attachments

Files attached to this notice, newest first
File Type Posted
230923 Direct-Digital Control System Connect to Existing N4.pdf PDF
1_b H - Renovate Building 4 IFC pages 12-14.pdf PDF
1_a G - Renovate Building 4 IFC pages 2-3.pdf PDF
1_a G - Renovate Building 4 IFC pages 4-6.pdf PDF
1_a G - Renovate Building 4 IFC pages 7-10.pdf PDF
1_a G - Renovate Building 4 IFC page 1.pdf PDF
3_Arch - Renovate Building 4 IFC pages 36-85.pdf PDF
5_Mech - Renovate Building 4 IFC pages 110-128.pdf PDF
6_Elec - Renovate Building 4 IFC pages 129-155.pdf PDF
2_C - L and S - Renovate Building 4 IFC pages 15-35.pdf PDF
4_FP and P - Renovate Building 4 IFC pages 86-109.pdf PDF
36C24624R0030 0005.docx DOCX document
Drawings.zip ZIP file
36C24624R0030 0004.docx DOCX document
INSTRUCTIONS CONDITIONS AND OTHER STATEMENTS TO BIDDERS-OFFERORS .docx DOCX document
Proposal Item I Cost Breakdown.xlsx XLSX spreadsheet
Fayetteville - Temp Fence.pdf PDF
230541 - NOISE AND VIBRATION CONTROL FOR HVAC PIPING AND EQUIPMENT.pdf PDF
230512 - GENERAL MOTOR REQUIREMENTS FOR HAVAC AND STEAM GENERATION EQUIPMENT.pdf PDF
014529 - TESTING LABORATORY SERVICES.pdf PDF
234000 - HVAC AIR CLEANING DEVICES.pdf PDF
232300 - REFRIGERANT PIPING.pdf PDF
36C24624R0030 0003.docx DOCX document
Proposal Item II Cost Breakdown.xlsx XLSX spreadsheet
Proposal Item III Cost Breakdown.xlsx XLSX spreadsheet
Proposal Item IV Cost Breakdown.xlsx XLSX spreadsheet
PL902 - PLUMBING DOMESTIC WATER ISOMETRICS.pdf PDF
232113 - Hydronic Piping.pdf PDF
233400 - HVAC FANS.pdf PDF
238216 - AIR COILS.pdf PDF
238200 - CONVECTION HEATING AND COOLING UNITS.pdf PDF
Proposal Item V Cost Breakdown.xlsx XLSX spreadsheet
Asbestos - Lead Paint Survey 12-31-2020.pdf PDF
Geotech Report_Fayetteville Bldg 4 Renovation.pdf PDF
230593 - TESTING ADJUSTING AND BALANCING FOR HVAC.pdf PDF
238129 - VARIABLE REFRIGERANT FLOW HVAC SYSTEMS.pdf PDF
230923 - DIRECT DIGITAL CONTROL SYSTEMS FOR HVAC.pdf PDF
238143 - AIR SOURCE UNITARY HEAT PUMPS.pdf PDF
230800 - COMMISSIONING OF HVAC SYSTEMS.pdf PDF
36C24624R0030 0002.docx DOCX document
Statement of Work - Renovate Historic Building 4.pdf PDF
STRUCTRAL DRAWING SET.pdf PDF
PLUMBING DRAWING SET.pdf PDF
MECHANICAL DRAWING SET.pdf PDF
LANDSCAPE DRAWING SET.pdf PDF
FIRE PROTECTION DRAWING SET.pdf PDF
ELECTRICAL DRAWING SET.pdf PDF
CIVIL DRAWING SET.pdf PDF
Specifications - Renovate Building 4 Issued For Construction.pdf PDF
Wage Determination.pdf PDF
Show all 50

This notice has more attachments on GovTribe.

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Z2AA - Renovate Historic Building 4 This notice · Latest solicitation Solicitation
Z2AA-- Renovate Historic Building 4 Project No: 565-20-101 Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity