This is an asbestos and lead paint survey report conducted by Terracon Consultants Inc. for Building 4 at the Fayetteville Veterans Affairs Medical Center campus in North Carolina, dated December 31, 2020.

The survey identified multiple asbestos-containing materials throughout the approximately 14,000-square-foot building, including air cell pipe insulation (40% chrysotile), various floor tiles and mastics (2-5% chrysotile), carpet glue and black mastic (2% chrysotile), black membrane/mastic (2% chrysotile), and white exterior caulk (5% chrysotile). Fire doors were assumed to contain asbestos. Lead paint sampling detected concentrations above laboratory reporting limits in 38 of 46 paint samples, with levels ranging from 0.024% to 65% by weight on various surfaces including metal doors, wood trim, window frames, columns, and decorative elements. The report provides detailed sampling locations, laboratory results, and photo documentation to support renovation activities planned for the building. The survey was conducted in accordance with EPA and OSHA regulations, with samples analyzed by EMSL Analytical Inc., an accredited laboratory.

View the file

Other files for this federal contract opportunity

Other files attached to Z2AA - Renovate Historic Building 4, newest first.
File Type Posted
36C24625C0027_1 Award Notice.docx DOCX document
230923 Direct-Digital Control System Connect to Existing N4.pdf PDF
36C24624R0030 0006.pdf PDF
1_a G - Renovate Building 4 IFC page 1.pdf PDF
1_b H - Renovate Building 4 IFC pages 12-14.pdf PDF
2_C - L and S - Renovate Building 4 IFC pages 15-35.pdf PDF
4_FP and P - Renovate Building 4 IFC pages 86-109.pdf PDF
36C24624R0030 0005.docx DOCX document
Specification Section 00 01 15 - LIST OF DRAWING SHEETS 01 21 25.pdf PDF
Proposal Item V Cost Breakdown.xlsx XLSX spreadsheet
Geotech Report_Fayetteville Bldg 4 Renovation.pdf PDF
230593 - TESTING ADJUSTING AND BALANCING FOR HVAC.pdf PDF
238129 - VARIABLE REFRIGERANT FLOW HVAC SYSTEMS.pdf PDF
230923 - DIRECT DIGITAL CONTROL SYSTEMS FOR HVAC.pdf PDF
238143 - AIR SOURCE UNITARY HEAT PUMPS.pdf PDF
230800 - COMMISSIONING OF HVAC SYSTEMS.pdf PDF
INSTRUCTIONS CONDITIONS AND OTHER STATEMENTS TO BIDDERS-OFFERORS .docx DOCX document
Proposal Item I Cost Breakdown.xlsx XLSX spreadsheet
Fayetteville - Temp Fence.pdf PDF
230541 - NOISE AND VIBRATION CONTROL FOR HVAC PIPING AND EQUIPMENT.pdf PDF
230512 - GENERAL MOTOR REQUIREMENTS FOR HAVAC AND STEAM GENERATION EQUIPMENT.pdf PDF
014529 - TESTING LABORATORY SERVICES.pdf PDF
234000 - HVAC AIR CLEANING DEVICES.pdf PDF
232300 - REFRIGERANT PIPING.pdf PDF
Statement of Proposal Items - 0003.docx DOCX document
Building 4 and 16 LBP Results.pdf PDF
Asbestos Reinspection Report - August 2019.pdf PDF
230711 - HVAC AND BOILER PLANT INSULATION.pdf PDF
230511 - COMMON WORK RESULTS FOR HVAC.pdf PDF
233100 - HVAC DUCTS AND CASINGS.pdf PDF
237200 - AIR TO AIR ENERGY RECOVERY EQUIPMENT.pdf PDF
233700 - AIR OUTLETS AND INLETS.pdf PDF
36C24624R0030 0003.docx DOCX document
Proposal Item II Cost Breakdown.xlsx XLSX spreadsheet
Proposal Item III Cost Breakdown.xlsx XLSX spreadsheet
36C24624R0030 0002.docx DOCX document
11-19-2024 Site Visit Attendance.pdf PDF
36C24624R0030 0001.docx DOCX document
Statement of Work - Renovate Historic Building 4.pdf PDF
Specifications - Renovate Building 4 Issued For Construction.pdf PDF
Wage Determination.pdf PDF
STRUCTRAL DRAWING SET.pdf PDF
ARCHITECTURAL DRAWING SET.pdf PDF
36C24624R0030_1.docx DOCX document
PLUMBING DRAWING SET.pdf PDF
MECHANICAL DRAWING SET.pdf PDF
LANDSCAPE DRAWING SET.pdf PDF
FIRE PROTECTION DRAWING SET.pdf PDF
ELECTRICAL DRAWING SET.pdf PDF
CIVIL DRAWING SET.pdf PDF
Show all 50

Z2AA - Renovate Historic Building 4 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Terracon Consultants, Inc. 2401 Brentwood Road Suite 107 Raleigh, North Carolina 27604

P (919) 873-2211 F (919) 873-9555 terracon.com

December 31, 2020

FFE, Inc.

110 Boggs Lane, Suite 170

Cincinnati, Ohio 45246

Attn: Clint Weekley

P: (513) 522-0956

E: clint.weekley@ffe-serv.com

Re: Asbestos and Lead Paint Survey Report

Fayetteville VAMC Building 4 2300 Ramsey Street Fayetteville, North Carolina 28301 Terracon Project No. 70207552

Dear Mr. Weekley:

The purpose of this report is to present the results of the asbestos and lead paint survey performed on December 7 and 8, 2020 at Building 4 located at the Fayetteville Veterans Affairs Medical

Center campus at 2300 Ramsey Street in Fayetteville, North Carolina. This survey was conducted in general accordance with the Subcontract Agreement between FFE, Inc. (client) and Terracon, dated November 23, 2020. We understand that these services were requested due to the planned renovation of the building.

Asbestos was detected in samples collected from the building. Lead was detected above laboratory reporting limits in samples collected. Please refer to the attached report for details.

Terracon appreciates the opportunity to provide these services to FFE, Inc. If you have any questions regarding this report, please contact the undersigned at (919) 873-2211.

Sincerely, Terracon Consultants Inc.

Alicia Coley, CIH Jeffrey A. Gurrie, CIH

Project Industrial Hygienist Authorized Project Reviewer

ASBESTOS AND LEAD PAINT

SURVEY REPORT

Fayetteville VAMC – Building 4

2300 Ramsey Street

Fayetteville, North Carolina 28301

Prepared For:

FFE, Inc.

Cincinnati, Ohio

Prepared By:

Terracon Consultants, Inc.

Raleigh, North Carolina

TABLE OF CONTENTS

Page No.

1.0 INTRODUCTION

1.1 Project Objective

2.0 BUILDING DESCRIPTION

3.0 FIELD ACTIVITIES

3.1 Asbestos

3.2 Lead Paint

4.0 REGULATORY OVERVIEW

4.1 Asbestos

4.2 Lead Paint

5.0 FINDINGS AND RECOMMENDATIONS

5.1 Asbestos

5.2 Lead Paint

6.0 GENERAL COMMENTS

Appendix A Asbestos Survey Sample Summary

Appendix B Materials Containing Asbestos Summary

Appendix C Asbestos Laboratory Analytical Report

Appendix D Lead Paint Survey Sample Summary

Appendix E Lead Paint Laboratory Analytical Report

Appendix F Photographs

Appendix G Accreditations

Responsive ■ Resourceful ■ Reliable 1

ASBESTOS AND LEAD PAINT SURVEY REPORT

FAYETTEVILLE VAMC – BUILDING 4

2300 RAMSEY STREET

FAYETTEVILLE, NORTH CAROLINA 28301

1.0 INTRODUCTION

Terracon Consultants, Inc. (Terracon) conducted an asbestos survey and lead paint sampling of

Building 4 located at the Fayetteville Veterans Affairs Medical Center campus at 2300 Ramsey

Street in Fayetteville, North Carolina. The survey was conducted on December 7 and 8, 2020 by

State of North Carolina Accredited Asbestos Building Inspectors in general accordance with

Subcontract Agreement between FFE, Inc. (client) and Terracon, dated November 23, 2020.

Building components within the building were visually assessed and homogeneous areas of suspect asbestos-containing materials (ACM) and suspect lead paint coatings were identified and documented. The survey was limited to safely accessible areas of the building. Suspect ACM samples were collected in general accordance with the sampling protocols outlined in

Environmental Protection Agency (EPA) regulation 40 CFR 763 (Asbestos Hazard Emergency

Response Act, AHERA). Suspect ACM samples were delivered to an accredited laboratory for analysis by Polarized Light Microscopy (PLM).

In addition to the asbestos survey, Terracon conducted a lead-containing paint survey. Paint chip samples were collected from representative surfaces and delivered to an accredited laboratory to perform total lead analysis by Flame Atomic Absorption Spectrophotometry (Flame AAS).

1.1 Project Objective

We understand this asbestos survey was requested due to planned renovation of the structure. We understand the purpose of these services is to identify and quantify ACM and lead-containing paint present prior to renovation or demolition activities. EPA regulation 40 CFR 61, Subpart M, National

Emission Standards for Hazardous Air Pollutants (NESHAP), prohibits the release of asbestos fibers to the atmosphere during renovation or demolition activities. The asbestos NESHAP requires that potentially regulated ACM be identified, classified and quantified prior to planned disturbances, renovation or demolition activities.

The Occupational Health and Safety Administration (OSHA) has promulgated a worker protection standard for the disturbance of lead-containing paints during demolition projects. The limited lead paint sampling was performed to meet informational needs to comply with the OSHA Lead in

Construction Standard (29 CRF 1926.62). Currently, proposed renovations or demolition activities which may impact lead paint is subject to OSHA regulation 29 CFR 1926.62 – Lead Exposure in

Construction.

Asbestos and Lead Paint Survey Report

Fayetteville VAMC – Building 4 ■ Fayetteville, North Carolina

December 31, 2020 ■ Terracon Project No. 70207552

Responsive ■ Resourceful ■ Reliable 2

2.0 BUILDING DESCRIPTION

According to client-provided documents, Building 4 is an approximately 14,000-square foot building, reportedly constructed in 1939. The building is a wood and concrete structure atop a concrete slab. The exterior of the building is finished with brick. The main roof is a gable roof with slate tiles. The porch roofs are flat roofs with rolled asphalt roofing. The front portico roof is a flat roof that appears to be finished with metal. Ceilings are finished with acoustical ceiling tile, and/or plaster, or are unfinished. Walls are painted concrete masonry unit (CMU), plaster, or drywall. The floors are finished with vinyl floor tile, carpet, and/or vinyl sheet flooring or are unfinished concrete.

3.0 FIELD ACTIVITIES

3.1 Asbestos

The survey was conducted by state of North Carolina Accredited Asbestos Building Inspectors

Alicia Coley (NC Accredited Asbestos Inspector Number 12548) and Cory Edwards (NC

Accredited Asbestos Inspector Number 12677). The survey was conducted in general accordance with the sample collection protocols established in EPA regulation 40 CFR 763

(AHERA). Copies of applicable accreditations are included in Appendix H. A summary of survey activities is provided below.

3.1.1 Visual Assessment

Our survey activities began with visual observation of the structure to identify homogeneous areas of suspect ACM. A homogeneous area consists of building materials that appear similar throughout in terms of color, texture and date of application. The assessment was conducted throughout visually accessible areas of the building. Building materials identified as concrete, glass, wood, masonry, metal or rubber were not considered suspect ACM.

3.1.2 Physical Assessment

A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material, which can be crumbled, pulverized or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.

3.1.3 Sample Collection

Based on results of our visual observations, bulk samples of suspect ACM were collected in general accordance with AHERA sampling protocols. Random samples of suspect materials were collected in each homogeneous area. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.

Responsive ■ Resourceful ■ Reliable 3

Terracon collected 108 bulk samples from 35 homogeneous areas of suspect ACM. A summary of suspect ACM samples collected during the survey is included as Appendix A. Photographs are included as Appendix F.

3.1.4 Sample Analysis

Bulk samples were submitted under chain of custody to EMSL Analytical, Inc. (EMSL) of Morrisville, North Carolina for analysis by PLM with dispersion staining techniques per EPA’s Method for the

Determination of Asbestos in Bulk Building Materials (600/R-93-116). The percentage of asbestos, where applicable, was determined by microscopic visual estimation. EMSL is accredited under the

National Voluntary Laboratory Accreditation Program NVLAP (Accreditation Number 200671-0).

The asbestos laboratory analytical report is provided in Appendix C.

3.2 Lead Paint Sampling

The lead paint sampling was conducted by Alicia Coley and Cory Edwards of Terracon. A paint chip sample was collected from homogenous painted surfaces identified to determine its lead content, measured by percent by weight. Suspect lead paint samples were collected in general accordance with the EPA’s work practice standards for conducting lead paint activities (40 CFR

745.227). Currently, proposed renovation and demolition activities that could potentially disturb lead paint are subject to the OSHA regulations (29 CFR 1926.62 – Lead).

The lead paint sampling began with the Terracon representatives walking the structure, observing painted surfaces, and selecting sample locations. After the sampling strategy was determined, Terracon collected 46 paint chip samples from homogeneous surfaces.

Paint chip samples were submitted under a chain of custody to EMSL of Kernersville, North

Carolina. Paint chip samples were analyzed by Flame Atomic Absorption Spectrophotometry method SW846-3050B/7000B. EMSL is an American Industrial Hygiene Association (AIHA)

Environmental Lead Laboratory Accreditation (ELLAP) accredited laboratory (ELLAP, Lab Code

102564), to perform Flame Atomic Absorption Spectrophotometry analysis. A summary of the paint chip samples collected during the survey is presented in Appendix D. The lead paint laboratory analytical report is provided in Appendix E.

4.0 REGULATORY OVERVIEW

4.1 Asbestos

The following sections provide a general overview to the applicable asbestos regulations. Please refer to the complete current regulation in order to verify compliance before any actions are initiated on an ACM.

Responsive ■ Resourceful ■ Reliable 4

4.1.1 NESHAP

The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. It also requires the identification and classification of existing building materials prior to demolition or renovation activities. Under NESHAP, asbestos-containing building materials are classified as either friable, Category I non-friable or Category II non-friable

ACM. Friable materials are those that, when dry, may be crumbled, pulverized or reduced to powder by hand pressure. Category I non-friable ACM includes packings, gaskets, resilient floor coverings and asphalt roofing products containing more than 1% asbestos. Category II non-friable ACM are any materials other than Category I materials that contain more than 1% asbestos.

Friable ACM, Category I and Category II non-friable ACM which is in poor condition and has become friable or which will be subjected to drilling, sanding, grinding, cutting or abrading and which could be crushed or pulverized during anticipated renovation or demolition activities are considered regulated ACM (RACM).

4.1.2 North Carolina State Regulations

In the state of North Carolina, asbestos activities are regulated by the North Carolina Department of Health and Human Services, Health Hazards Control Unit (HHCU) under 10A NCAC 41C Section

.0600 – Asbestos Hazard Management Program (AHMP). The AHMP requires that any asbestos-related activity conducted in a public building be performed by personnel accredited by the HHCU.

Asbestos abatement must be conducted under the direct supervision of a North Carolina accredited supervisor, except that permitted removals of roofing products may be conducted under the direct supervision of a North Carolina accredited roofing supervisor. An asbestos abatement design must be prepared by a North Carolina accredited abatement designer for each individually permitted removal of more than 3000 square feet (281 square meters), 1500 linear feet (462 meters) or 656 cubic feet (18 cubic meters), of regulated asbestos containing materials conducted in public areas.

Third-party air monitoring must be conducted during the abatement activities in accordance with

AHMP requirements.

AHMP requires that no person remove more than 35 cubic feet (1 cubic meter), 160 square feet (15 square meters), or 260 linear feet (80 linear meters) of regulated asbestos containing material, without a permit issued by the HHCU. Applications must be postmarked or received by the HHCU at least 10 working days prior to the scheduled removal start date.

4.1.3 OSHA

OSHA’s general industry asbestos standard (29 CFR 1910.1001) requires employers to exercise due diligence in complying with the requirements to inform their employees and affected contractors working in the facility about the presence and location of both ACM and materials assumed to contain asbestos.

Responsive ■ Resourceful ■ Reliable 5

The OSHA Asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos during construction and maintenance activities. The standard classifies construction and maintenance activities which could disturb ACM, and specifies work practices and precautions which employers must follow when engaging in each class of regulated work. States which administer their own federally-approved state OSHA programs may require additional precautions.

A full copy of the OSHA asbestos standard for general and construction industry may be found at

OSHA’s website (www.osha.gov) and should be referenced for specific information.

4.2 Lead Paint

The lead paint sampling activities were conducted in general accordance with the EPA’s work practice standards for conducting lead paint activities (40 CFR 745, and State and local regulations) to meet informational needs to comply with the OSHA Lead in Construction Standard. Lead is regulated by the Environmental Protection Agency (EPA) and the Occupational Safety and Health

Administration (OSHA).

The Resource Conservation and Recovery Act (RCRA) gave the USEPA authority to regulate the waste status of demolition or renovation debris, including lead-containing materials. Specific notification and testing requirements must be addressed prior to transporting, treating, storing, or disposing of hazardous wastes. Lead containing wastes are considered hazardous waste under

RCRA if Toxicity Characteristic Leaching Procedure (TCLP) results exceed 5 milligrams per liter

(mg/L). EPA exempts from most RCRA requirements those generators whose combined hazardous waste generation is less than 100 kilograms (kg) per month.

Detectable lead quantities may constitute a lead dust hazard during renovation/demolition activities.

Personnel performing renovation/demolition activities that may disturb painted components with concentrations of lead above the designated analytical detection limit should comply with all current

OSHA regulations in order to minimize employee exposure. OSHA defines lead-based paint as a paint, which contains lead, regardless of the concentration. Currently, any proposed renovation/demolition is subject to the OSHA regulations (29 CFR 1926.62 – Lead). The OSHA regulation defines specific training requirements, engineering controls and working practices for construction personnel subject to this standard. Occupational exposure to lead occurring in the course of construction work, including maintenance activities, painting, alteration and repairs is subject to the OSHA Lead Exposure in Construction standard.

Construction work covered by 29 CFR 1926.62 includes any repair or renovation activities or other activities that disturb in-place lead-containing materials, but does not include routine cleaning and repainting where there is insignificant damage, wear, or corrosion of existing lead-containing coatings or substrates. Employers must assure that no employee will be exposed to lead at concentrations greater than 50 micrograms per cubic meter (g/m3) averaged over an eight-hour period without adequate protection. The OSHA Standard also establishes an action level of 30 g/m3 which if exceeded triggers the requirement for medical monitoring.

http://www.osha.gov/

Responsive ■ Resourceful ■ Reliable 6

The above overview is not intended to be inclusive of all potentially pertinent regulatory information.

The relevant EPA and OSHA standards should be consulted prior to undertaking activities involving the demolition, renovation, or maintenance of surfaces coated with lead-based paints.

5.0 FINDINGS AND RECOMMENDATIONS

5.1 Asbestos

Asbestos was identified at concentrations greater than 1% in the following materials:

▪ Air Cell Pipe Insulation

▪ 12” x 12” Beige with Tan Specks Floor Tile and Mastic – mastic assumed to be remaining in areas from previous abatement

▪ 12” x 12” Blue with Red Specks Floor Tile and Mastic - mastic assumed to be remaining in areas from previous abatement

▪ 12” x 12” Tri-blue Floor Tile and Mastic – mastic only

▪ Black Floor Mastic

▪ Carpet Glue and Black Mastic

▪ Black Membrane/Mastic (under ceramic floor tile) – mastic only

▪ Tan Floor Tile and Mastic – mastic only

▪ 12” x 12” Tan with Brown Specks Floor Tile and Mastic – tile and mastic

▪ 12” x 12” Beige with Brown Specks Floor Tile and Mastic – mastic only; floor tile contains

<1% asbestos

▪ White Exterior Caulk at Brick and Wood

In addition, the following material is assumed to contain asbestos in concentrations greater than 1% at the VAMC representative’s request.

▪ Fire Doors

Asbestos was identified at concentrations less than 1% in the following material:

▪ 12” x 12” Beige with Brown Specks Floor Tile and Mastic – floor tile contains <1% asbestos;

mastic contains greater than 1% asbestos

▪ Window Glazing

Regarding materials with less than 1% asbestos, OSHA does regulate these materials and requires specified work practice requirements and prohibitions regardless of exposure levels to employees, including (but not limited to):

▪ Use of wet methods, prompt cleanup and disposal in leak-proof containers;

Responsive ■ Resourceful ■ Reliable 7

▪ Use of compressed air or high-speed abrasive disc saws not equipped with point-of cut ventilators or HEPA-filtered enclosures are prohibited;

▪ The employee is required to document employee exposures via a “competent person” relative to published permissible exposure limits to ascertain expected exposures to asbestos during the work operation.

If additional suspect material is found during renovation or demolition activities, they should be assumed to contain asbestos until laboratory analysis can confirm or deny their asbestos content.

If the final scope of work changes to include areas or materials other than those sampled during this sampling event, additional investigations will be necessary.

Terracon recommends that the identified, assumed, and less than 1% asbestos ACM be removed and disposed of by a State of North Carolina licensed asbestos abatement contractor prior to renovation. Please refer to Appendix B for specific materials and locations of the identified, assumed, and less than 1% asbestos ACM. A summary of suspect materials sampled is provided in Appendix A. Laboratory analytical reports are provided in Appendix C. Photographs are provided in Appendix F.

5.2 Lead Paint

Lead was detected above laboratory reporting limits in 38 of the 46 paint samples collected as listed below:

▪ Green Paint on Metal Door

▪ White Paint on Poured Concrete Wall

▪ White Paint on Concrete at Window

▪ Beige Paint on Metal Stair Post

▪ Beige Paint on Metal Stair Stringer

▪ White Paint on Metal Stair Tread (Exterior Fire Escape)

▪ Red Paint on Metal Stair Roof/Overhang (Exterior Fire Escape)

▪ White Paint on Exterior Wood Fascia

▪ White Paint on Exterior Wood Trim at Soffit

▪ White Paint on Exterior Wood Soffit

▪ Black Paint on Metal Decorative Insert (Parapet Wall)

▪ Red Paint on Metal Stair Handrail (Exterior Fire Escape)

▪ Beige Paint on Wood Window Frame

▪ Gray Paint on Metal I-Beam

▪ Off-white Paint on Plaster – multiple samples

▪ Tan Paint on Wood Shelf (Closet)

▪ Tan Paint on Wood Door (Closet)

▪ Tan Paint on Wood Door

▪ Tan Paint on Metal Door Frame

▪ Beige Paint on Wood Window Sill

Responsive ■ Resourceful ■ Reliable 8

▪ Tan Paint on Metal Radiator Cover

▪ Beige Paint on Metal Radiator Cover

▪ Off-white Paint on Wood Shelf (Closet)

▪ Off-white Paint on Wood Door (Closet)

▪ Off-white Paint on Wood Window Sill

▪ Off-white Paint on Metal Door Frame

▪ Off-white Paint on Wood Door – multiple samples

▪ Off-white Paint on Window Sill

▪ Off-white Paint on Wood Door Trim

▪ Black Paint on Metal Decorative Window Pane Insert

▪ Off-white Paint on Exterior Wood Door Frame

▪ Off-white Paint on Exterior Wood Column

▪ Off-white Paint on Exterior Wood Door

▪ Off-white Paint on Exterior Metal Door

▪ Off-white Paint on Exterior Wood Door Trim

A summary of the paint chip samples collected during the survey is presented in Appendix D.

The lead paint laboratory analytical report is provided in Appendix E.

Contractors should be made aware of the presence of the identified lead coatings, so that they may maintain compliance with worker protection regulations, employ lead-safe work practices, and/or conduct a negative exposure assessment per OSHA (29 CFR 1926.62 – Lead Exposure in

Construction).

6.0 GENERAL COMMENTS

This asbestos and lead paint survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during our survey of the building.

This report has been prepared on behalf of and exclusively for use by FFE, Inc. for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information, which may have been used in the preparation of this report. No warranty, expressed or implied is made.

APPENDIX A

ASBESTOS SURVEY SAMPLE SUMMARY

HA Sample No. Description Sample Location Lab Results

1 4-1 Air Cell Pipe Insulation Crawlspace 40% Chrysotile

1 4-2 Air Cell Pipe Insulation Crawlspace Positive Stop (Not Analyzed)

1 4-3 Air Cell Pipe Insulation Crawlspace Positive Stop (Not Analyzed)

2 4-4 Felt Paper Crawlspace None Detected

2 4-5 Felt Paper Crawlspace None Detected

2 4-6 Felt Paper Crawlspace None Detected

3 4-7 Black Waterproofing Crawlspace None Detected

3 4-8 Black Waterproofing Crawlspace None Detected

3 4-9 Black Waterproofing Crawlspace None Detected

4 4-10 Window Glazing Crawlspace <1% Chrysotile

4 4-11 Window Glazing Crawlspace <1% Chrysotile

4 4-12 Window Glazing Crawlspace <1% Chrysotile

5 4-13 White Sealant Crawlspace None Detected

5 4-14 White Sealant Crawlspace None Detected

5 4-15 White Sealant Crawlspace None Detected

6 4-16 Canvas Wrap over Mud Mechanical Room - Tank Wrap: None Detected

Mud: None Detected

6 4-17 Canvas Wrap over Mud Mechanical Room - Tank Wrap: None Detected

Mud: None Detected

6 4-18 Canvas Wrap over Mud Mechanical Room - Tank Wrap: None Detected

Mud: None Detected

7 4-19 White Mastic Mechanical Room - Fiberglass

Duct Insulation None Detected

7 4-20 White Mastic Mechanical Room - Fiberglass

Duct Insulation None Detected

7 4-21 White Mastic Mechanical Room - Fiberglass

Duct Insulation None Detected

8 4-22 2'x2' White Ceiling Tile with Dots and Small

Lines Basement Hallway at Rm. 002 None Detected

8 4-23 2'x2' White Ceiling Tile with Dots and Small

Lines Room 009 None Detected

8 4-24 2'x2' White Ceiling Tile with Dots and Small

Lines Room 117 None Detected

9 4-25 Drywall, Joint Compound Basement Hallway at Rm. 002 Composite: None Detected

9 4-26 Drywall, Joint Compound Rm. 010 - Men's Restroom Composite: None Detected

9 4-27 Drywall, Joint Compound Room 009 Composite: None Detected

10 4-28 Brown Fire Caulk Basement Hallway at Rm. 002 None Detected

10 4-29 Brown Fire Caulk Basement Hallway at Rm. 002 None Detected

10 4-30 Brown Fire Caulk Basement Hallway at Rm. 002 None Detected

11 4-31 12"x12" Beige with Tan Specks Floor Tile and Mastic Basement Hallway at Rm. 002

Floor Tile: None Detected

Mastic: None Detected

11 4-32 12"x12" Beige with Tan Specks Floor Tile and Mastic Basement Hallway at Rm. 009

Floor Tile: None Detected

Mastic: None Detected

11 4-33 12"x12" Beige with Tan Specks Floor Tile and Mastic Basement Hallway at Rm. 011

Floor Tile: None Detected

Mastic: None Detected

Fayetteville, North Carolina

Terracon Project No. 70207552

Appendix A

ASBESTOS SURVEY SAMPLE SUMMARY

2300 Ramsey Street

Fayetteville VAMC - Building 4

A-1

Fayetteville, North Carolina

Terracon Project No. 70207552

Appendix A

ASBESTOS SURVEY SAMPLE SUMMARY

2300 Ramsey Street

Fayetteville VAMC - Building 4

12 4-34 12" x 12" Blue with White and Red

Specks Floor Tile and Mastic Room 002

Floor Tile: None Detected

Mastic: None Detected

12 4-35 12" x 12" Blue with White and Red

Specks Floor Tile and Mastic Room 006

Floor Tile: None Detected

Mastic: 5% Chrysotile

12 4-36 12" x 12" Blue with White and Red

Specks Floor Tile and Mastic Room 005

Floor Tile: None Detected

Mastic: Positive Stop (Not Analyzed)

13 4-37 6" Navy Blue Cove Base and Mastic Basement Hallway at Rm. 002 Cove Base: None Detected

Mastic: None Detected

13 4-38 6" Navy Blue Cove Base and Mastic Basement Hallway at Rm. 011 Cove Base: None Detected

Mastic: None Detected

13 4-39 6" Navy Blue Cove Base and Mastic Room 006 Cove Base: None Detected

Mastic: None Detected

14 4-40 Plaster Basement Hallway at Rm. 004 Skim Coat: None Detected

Base Coat: None Detected

14 4-41 Plaster Room 011 - Women's

Restroom

Skim Coat: None Detected

Base Coat: None Detected

14 4-42 Plaster Room 117 Skim Coat: None Detected

Base Coat: None Detected

14 4-43 Plaster Room 117 Skim Coat: None Detected

Base Coat: None Detected

14 4-44 Plaster Room 111 Skim Coat: None Detected

Base Coat: None Detected

14 4-45 Plaster 2nd Floor Hallway at Rm. 211 Skim Coat: None Detected

Base Coat: None Detected

14 4-46 Plaster 2nd Floor Hallway at Rm. 212 Skim Coat: None Detected

Base Coat: None Detected

15 4-47 Black Floor Mastic Room 012 5% Chrysotile

15 4-48 Black Floor Mastic 1st Floor Hallway at Rm. 113 Positive Stop (Not Analyzed)

15 4-49 Black Floor Mastic 1st Floor Hallway at Rm. 113 Positive Stop (Not Analyzed)

16 4-50 CMU Surface Block Filler Room 012 None Detected

16 4-51 CMU Surface Block Filler Room 012 None Detected

16 4-52 CMU Surface Block Filler Room 012 None Detected

17 4-53 White Ceramic Wall Tile Mastic and Grout Room 011 - Women's

Restroom

Mastic: None Detected

Grout: None Detected

17 4-54 White Ceramic Wall Tile Mastic and Grout Room 011 - Women's

Restroom

Mastic: None Detected

Grout: None Detected

17 4-55 White Ceramic Wall Tile Mastic and Grout Room 011 - Women's

Restroom

Mastic: None Detected

Grout: None Detected

18 4-56 2'x2' White Ceiling Tile with Dots and Lines Room 010 - Men's Restroom

Closet None Detected

18 4-57 2'x2' White Ceiling Tile with Dots and Lines Room 118 None Detected

18 4-58 2'x2' White Ceiling Tile with Dots and Lines Room 120 None Detected

19 4-59 2' x 4' White Ceiling Tile with Dots and Lines Room 011 - Women's

Restroom None Detected

19 4-60 2' x 4' White Ceiling Tile with Dots and Lines Room 109 None Detected

19 4-61 2' x 4' White Ceiling Tile with Dots and Lines Room 109 None Detected

20 4-62 2" Tan Porcelain Floor Tile Mortar and Grout Room 010 - Men's Restroom Mortar: None Detected

Grout: None Detected

20 4-63 2" Tan Porcelain Floor Tile Mortar and Grout Room 010 - Men's Restroom Mortar: None Detected

Grout: None Detected

A-2

Terracon Project No. 70207552

Appendix A

ASBESTOS SURVEY SAMPLE SUMMARY

2300 Ramsey Street

Fayetteville VAMC - Building 4

20 4-64 2" Tan Porcelain Floor Tile Mortar and Grout Room 010 - Men's Restroom Mortar: None Detected

Grout: None Detected

21 4-65 Blue with White and Blue Specks Vinyl

Sheet Flooring Room 004

Sheet Flooring 1: None Detected

Sheet Flooring 2: None Detected

Mastic: None Detected

21 4-66 Blue with White and Blue Specks Vinyl

Sheet Flooring Room 004

Sheet Flooring 1: None Detected

Sheet Flooring 2: None Detected

Mastic: None Detected

21 4-67 Blue with White and Blue Specks Vinyl

Sheet Flooring Room 004

Sheet Flooring 1: None Detected

Sheet Flooring 2: None Detected

Mastic: None Detected

22 4-68 4" Cream Cove Base and Mastic Room 004 Cove Base: None Detected

Mastic: None Detected

22 4-69 4" Cream Cove Base and Mastic Room 004 Cove Base: None Detected

Mastic: None Detected

22 4-70 4" Cream Cove Base and Mastic Room 004 Cove Base: None Detected

Mastic: None Detected

23 4-71 Red Fire Caulk Room 010 - Men's Restroom

Closet None Detected

23 4-72 Red Fire Caulk Room 010 - Men's Restroom

Closet None Detected

23 4-73 Red Fire Caulk Room 010 - Men's Restroom

Closet None Detected

24 4-74 Off-white Duct Mastic on Foil-backed

Fiberglass Insulation Room 010 - Men's Restroom Mastic: None Detected

24 4-75 Off-white Duct Mastic on Foil-backed

Fiberglass Insulation Room 004 Mastic: None Detected

24 4-76 Off-white Duct Mastic on Foil-backed

Fiberglass Insulation Room 004 Mastic: None Detected

25 4-77 Green Faux Terrazzo Vinyl Sheet Flooring Room 004 None Detected

25 4-78 Green Faux Terrazzo Vinyl Sheet Flooring Room 004 None Detected

25 4-79 Green Faux Terrazzo Vinyl Sheet Flooring Room 004 None Detected

26 4-80 2'x4' White Ceiling Tile with Dots and Y's Room 004 None Detected

26 4-81 2'x4' White Ceiling Tile with Dots and Y's Room 004 None Detected

26 4-82 2'x4' White Ceiling Tile with Dots and Y's Room 004 None Detected

27 4-83 Gray Stair Tread and Mastic Basement Stair Tread: None Detected

Mastic: None Detected

27 4-84 Gray Stair Tread and Mastic Basement Stair Tread: None Detected

Mastic: None Detected

27 4-85 Gray Stair Tread and Mastic Basement Stair Tread: None Detected

Mastic: None Detected

28 4-86 4" Black Cove Base and Mastic Room 009 Cove Base: None Detected

Mastic: None Detected

28 4-87 4" Black Cove Base and Mastic Room 009 Cove Base: None Detected

Mastic: None Detected

28 4-88 4" Black Cove Base and Mastic Room 009 Cove Base: None Detected

Mastic: None Detected

29 4-89 Carpet Glue and Black Mastic Room 009 Glue: None Detected

Mastic: 2% Chrysotile

29 4-90 Carpet Glue and Black Mastic Room 009 Glue: None Detected

Mastic: Positive Stop (Not Analyzed)

29 4-91 Carpet Glue and Black Mastic Room 009 Glue: <1% Chrysotile

Mastic: Positive Stop (Not Analyzed)

A-3

Terracon Project No. 70207552

Appendix A

ASBESTOS SURVEY SAMPLE SUMMARY

2300 Ramsey Street

Fayetteville VAMC - Building 4

30 4-92 12"x12" Tri-blue Floor Tile and Mastic Rm. 008 - Mechanical Floor Tile: None Detected

Mastic: 5% Chrysotile

30 4-93 12"x12" Tri-blue Floor Tile and Mastic Rm. 008 - Mechanical Floor Tile: None Detected

Mastic: Positive Stop (Not Analyzed)

30 4-94 12"x12" Tri-blue Floor Tile and Mastic Rm. 008 - Mechanical Floor Tile: None Detected

Mastic: Positive Stop (Not Analyzed)

31 4-95 Blue Fire Caulk Room 007B None Detected

31 4-96 Blue Fire Caulk Room 007B None Detected

31 4-97 Blue Fire Caulk Room 007B None Detected

32 4-98 Black Tar Room 007B - Ceiling

Penetrations None Detected

32 4-99 Black Tar Room 007B - Ceiling

Penetrations None Detected

32 4-100 Black Tar Room 007B - Ceiling

Penetrations None Detected

33 4-101 6" Brown Cove Base and Mastic Room 117 Cove Base: None Detected

Mastic: None Detected

33 4-102 6" Brown Cove Base and Mastic Room 117 Cove Base: None Detected

Mastic: None Detected

33 4-103 6" Brown Cove Base and Mastic Room 121 Cove Base: None Detected

Mastic: None Detected

34 4-104 Drywall, Joint Compound Room 117 Composite: None Detected

34 4-105 Drywall, Joint Compound Room 101 Composite: None Detected

34 4-106 Drywall, Joint Compound Room 102 Composite: None Detected

35 4-107 6" Gray Cove Base and Mastic Room 203B Cove Base: None Detected

Mastic: None Detected

35 4-108 6" Gray Cove Base and Mastic 2nd Floor Hallway at Rm. 212 Cove Base: None Detected

Mastic: None Detected

35 4-109 6" Gray Cove Base and Mastic 2nd Floor Hallway at Rm. 218 Cove Base: None Detected

Mastic: None Detected

36 4-110 12"x12" Off-white with Tan Specks Floor

Tile and Mastic Room 120

Floor Tile: None Detected

Mastic: None Detected

Leveler: None Detected

36 4-111 12"x12" Off-white with Tan Specks Floor

Tile and Mastic Room 102

Floor Tile: None Detected

Mastic: None Detected

Leveler: None Detected

36 4-112 12"x12" Off-white with Tan Specks Floor

Tile and Mastic 1st Floor Lobby

Floor Tile: None Detected

Mastic: None Detected

Leveler: None Detected

37 4-113 6" Black Cove Base and Mastic Room 120 Cove Base: None Detected

Mastic: None Detected

37 4-114 6" Black Cove Base and Mastic Room 120 Cove Base: None Detected

Mastic: None Detected

37 4-115 6" Black Cove Base and Mastic Room 120 Cove Base: None Detected

Mastic: None Detected

38 4-116 2'x4' White Ceiling Tile with Dots and Wide

Lines Room 116 - Restroom None Detected

38 4-117 2'x4' White Ceiling Tile with Dots and Wide

Lines Room 116 - Restroom None Detected

38 4-118 2'x4' White Ceiling Tile with Dots and Wide

Lines Room 116 - Restroom None Detected

39 4-119 12"x12" Tan with Brown Specks Floor

Tile and Mastic Room 116 - Restroom Closet

Floor Tile: 2% Chrysotile

Mastic: 2% Chrysotile

39 4-120 12"x12" Tan with Brown Specks Floor

Tile and Mastic Room 116 - Restroom Closet Positive Stop (Not Analyzed)

A-4

Terracon Project No. 70207552

Appendix A

ASBESTOS SURVEY SAMPLE SUMMARY

2300 Ramsey Street

Fayetteville VAMC - Building 4

39 4-121 12"x12" Tan with Brown Specks Floor

Tile and Mastic Room 116 - Restroom Closet Positive Stop (Not Analyzed)

40 4-122 Black Membrane/Mastic Room 116 - Restroom (Under

Tile Floor)

Membrane: None Detected

Mastic: 2% Chrysotile

40 4-123 Black Membrane/Mastic Room 116 - Restroom (Under

Tile Floor)

Membrane: None Detected

Mastic: Positive Stop (Not Analyzed)

40 4-124 Black Membrane/Mastic Room 116 - Restroom (Under

Tile Floor)

Membrane: None Detected

Mastic: Positive Stop (Not Analyzed)

41 4-125 Ceramic Floor Tile Mortar and Grout Room 116 - Restroom Mortar: None Detected

Grout: None Detected

41 4-126 Ceramic Floor Tile Mortar and Grout Room 116 - Restroom Mortar: None Detected

Grout: None Detected

41 4-127 Ceramic Floor Tile Mortar and Grout Room 116 - Restroom Mortar: None Detected

Grout: None Detected

42 4-128 Green Ceramic Wall Tile Mastic and

Grout Room 116 - Restroom

Mastic: 3% Chrysotile (Contaminated with Mastic from HA 40)

Grout: None Detected

42 4-129 Green Ceramic Wall Tile Mastic and

Grout Room 116 - Restroom

Mastic: Positive Stop (Not Analyzed)

Grout: None Detected

42 4-130 Green Ceramic Wall Tile Mastic and

Grout Room 116 - Restroom

Mastic: Positive Stop (Not Analyzed)

Grout: None Detected

43 4-131 Tan Carpet Glue Room 203 None Detected

43 4-132 Tan Carpet Glue Room 107 None Detected

43 4-133 Tan Carpet Glue Room 207 None Detected

44 4-134 Tan Carpet Glue and White Leveling

Compound 1st Floor Hallway at Rm. 113

Glue: None Detected

Leveling Compound: None Detected

44 4-135 Tan Carpet Glue and White Leveling

Compound 1st Floor Hallway at Rm. 113

Glue: None Detected

Leveling Compound: None Detected

44 4-136 Tan Carpet Glue and White Leveling

Compound 1st Floor Hallway at Rm. 113

Glue: None Detected

Leveling Compound: None Detected

45 4-137 Pink Ceramic Floor Tile Mortar and Grout Room 112 - Restroom Mortar: None Detected

Grout: None Detected

45 4-138 Pink Ceramic Floor Tile Mortar and Grout Room 112 - Restroom Mortar: None Detected

Grout: None Detected

45 4-139 Pink Ceramic Floor Tile Mortar and Grout Room 112 - Restroom Mortar: None Detected

Grout: None Detected

46 4-140 Pink Fire Caulk Room 111 - Housekeeping None Detected

46 4-141 Pink Fire Caulk Room 111 - Housekeeping None Detected

46 4-142 Pink Fire Caulk Room 111 - Housekeeping None Detected

47 4-143 White HVAC Duct Tape Room 109A None Detected

47 4-144 White HVAC Duct Tape Room 109A None Detected

47 4-145 White HVAC Duct Tape Room 109A None Detected

48 4-146 Tan Floor Tile and Mastic 1st Floor Lobby at Stairs

(Bottom Layer)

Floor Tile: None Detected

Mastic: <1% Chrysotile

48 4-147 Tan Floor Tile and Mastic 1st Floor Lobby at Stairs

(Bottom Layer)

Floor Tile: None Detected

Mastic: <1% Chrysotile

48 4-148 Tan Floor Tile and Mastic 1st Floor Lobby at Stairs

(Bottom Layer)

Floor Tile: None Detected

Mastic 1: 5% Chrysotile

Mastic 2: None Detected

49 4-149 Faux Wood Flooring Room 105 Closet None Detected

49 4-150 Faux Wood Flooring Room 105 Closet None Detected

A-5

Terracon Project No. 70207552

Appendix A

ASBESTOS SURVEY SAMPLE SUMMARY

2300 Ramsey Street

Fayetteville VAMC - Building 4

49 4-151 Faux Wood Flooring Room 105 Closet None Detected

50 4-152 18"x18" Tan/Gray Faux Stone Pattern Vinyl

Floor Tile 2nd Floor - Kitchen

Floor Tile: None Detected

Mastic: None Detected

50 4-153 18"x18" Tan/Gray Faux Stone Pattern Vinyl

Floor Tile 2nd Floor - Kitchen

Floor Tile: None Detected

Mastic: None Detected

50 4-154 18"x18" Tan/Gray Faux Stone Pattern Vinyl

Floor Tile 2nd Floor - Kitchen

Floor Tile: None Detected

Mastic: None Detected

51 4-155 12"x12" Tri-brown Floor Tile and Mastic 2nd Floor - Kitchen Floor Tile: None Detected

Mastic: None Detected

51 4-156 12"x12" Tri-brown Floor Tile and Mastic 2nd Floor - Kitchen Floor Tile: None Detected

Mastic: None Detected

51 4-157 12"x12" Tri-brown Floor Tile and Mastic 2nd Floor - Kitchen Floor Tile: None Detected

Mastic: None Detected

52 4-158 12"x12" Beige with Brown Specks Floor

Tile and Mastic

2nd Floor - Kitchen (Bottom

Layer)

Floor Tile: <1% Chrysotile

Mastic 1: 3% Chrysotile

Mastic 2: None Detected

52 4-159 12"x12" Beige with Brown Specks Floor

Tile and Mastic

2nd Floor - Kitchen (Bottom

Layer)

Floor Tile: <1% Chrysotile

Mastic 1: Positive Stop (Not Analyzed)

Mastic 2: None Detected

52 4-160 12"x12" Beige with Brown Specks Floor

Tile and Mastic 2nd Floor - Stairwell

Floor Tile: <1% Chrysotile

Mastic 1: Positive Stop (Not Analyzed)

Mastic 2: Layer Not Present

53 4-161 Gray Leveling Compound Room 207 Leveling Compound: None Detected

Mastic: None Detected

53 4-162 Gray Leveling Compound Room 207 Leveling Compound: None Detected

Mastic: None Detected

53 4-163 Gray Leveling Compound 2nd Floor Hallway at Rm. 205 Leveling Compound: None Detected

Mastic: None Detected

54 4-164 Blue and White Ceramic Wall Tile Mastic and Grout

Room 210 - Women's

Restroom

Mastic: None Detected

Grout: None Detected

54 4-165 Blue and White Ceramic Wall Tile Mastic and Grout

Room 210 - Women's

Restroom

Mastic: None Detected

Grout: None Detected

54 4-166 Blue and White Ceramic Wall Tile Mastic and Grout

Room 210 - Women's

Restroom

Mastic: None Detected

Grout: None Detected

55 4-167 Blue and Gray Ceramic Floor Tile Mortar and Grout

Room 210 - Women's

Restroom

Mortar: None Detected

Grout: None Detected

55 4-168 Blue and Gray Ceramic Floor Tile Mortar and Grout

Room 210 - Women's

Restroom

Mortar: None Detected

Grout: None Detected

55 4-169 Blue and Gray Ceramic Floor Tile Mortar and Grout

Room 210 - Women's

Restroom

Mortar: None Detected

Grout: None Detected

56 4-170 Gray Roof Caulk Flat Roof on North End of

Building - 2nd Floor Access None Detected

56 4-171 Gray Roof Caulk Flat Roof on North End of

Building - 2nd Floor Access None Detected

56 4-172 Gray Roof Caulk Flat Roof on North End of

Building - 2nd Floor Access None Detected

57 4-173 Beige Roof Caulk Flat Roof on North End of

Building - 2nd Floor Access None Detected

57 4-174 Beige Roof Caulk Flat Roof on North End of

Building - 2nd Floor Access None Detected

57 4-175 Beige Roof Caulk Flat Roof on North End of

Building - 2nd Floor Access None Detected

58 4-176 Gray Rolled Asphalt Roofing Flat Roof on North End of

Building - 2nd Floor Access

Shingle 1: None Detected

Shingle 2: None Detected

58 4-177 Gray Rolled Asphalt Roofing Flat Roof on North End of

Building - 2nd Floor Access

Shingle 1: None Detected

Shingle 2: None Detected

A-6

Terracon Project No. 70207552

Appendix A

ASBESTOS SURVEY SAMPLE SUMMARY

2300 Ramsey Street

Fayetteville VAMC - Building 4

58 4-178 Gray Rolled Asphalt Roofing Flat Roof on North End of

Building - 2nd Floor Access

Shingle 1: None Detected

Shingle 2: None Detected

59 4-179 Black Flashing Flat Roof on North End of

Building - 2nd Floor Access

Roofing 1: None Detected

Roofing 2: None Detected

Roofing 3: None Detected

Roofing 4: None Detected

59 4-180 Black Flashing Flat Roof on North End of

Building - 2nd Floor Access

Roofing 1: None Detected

Roofing 2: None Detected

Roofing 3: Layer Not Present

Roofing 4: None Detected

59 4-181 Black Flashing Flat Roof on North End of

Building - 2nd Floor Access

Roofing 1: None Detected

Roofing 2: None Detected

Roofing 3: Layer Not Present

Roofing 4: None Detected

60 4-182 White Interior Window Caulk Attic None Detected

60 4-183 White Interior Window Caulk Attic None Detected

60 4-184 White Interior Window Caulk Attic None Detected

61 4-185 Roofing Felt Paper Attic None Detected

61 4-186 Roofing Felt Paper Attic None Detected

61 4-187 Roofing Felt Paper Attic None Detected

62 4-188 Gray Duct Mastic Attic None Detected

62 4-189 Gray Duct Mastic Attic None Detected

62 4-190 Gray Duct Mastic Attic None Detected

63 4-191 Brown Cellulose Board over Black

Felt/Mastic Room 116 - Restroom

Fiberboard: None Detected

Felt/Mastic: None Detected

63 4-192 Brown Cellulose Board over Black

Felt/Mastic Room 116 - Restroom

Fiberboard: None Detected

Felt/Mastic: None Detected

63 4-193 Brown Cellulose Board over Black

Felt/Mastic Room 116 - Restroom

Fiberboard: None Detected

Felt/Mastic: None Detected

64 4-194 White Exterior Caulk - at Brick and Wood Exterior - South Door None Detected

64 4-195 White Exterior Caulk - at Brick and Wood Exterior - North Window None Detected

64 4-196 White Exterior Caulk - at Brick and Wood Exterior - Front Door 5% Chrysotile

65 4-197 White Exterior Caulk - at Metal Window

Trim Exterior - South Window None Detected

65 4-198 White Exterior Caulk - at Metal Window

Trim Exterior -North Window None Detected

65 4-199 White Exterior Caulk - at Metal Window

Trim Exterior - Southwest Window None Detected

66 4-200 White Expansion Joint Caulk Exterior - ADA Ramp at South

End of Building None Detected

66 4-201 White Expansion Joint Caulk Exterior - ADA Ramp at South

End of Building None Detected

66 4-202 White Expansion Joint Caulk Exterior - ADA Ramp at South

End of Building None Detected

67 4-203 Tan Exterior Caulk Exterior - East Door None Detected

67 4-204 Tan Exterior Caulk Exterior - East Window None Detected

67 4-205 Tan Exterior Caulk Exterior - West Window None Detected

*Highlighted samples indicate materials with <1% asbestos.

*Highlighted and bolded samples indicate materials with >1% asbestos.

A-7

APPENDIX B

MATERIALS CONTAINING ASBESTOS SUMMARY

HA Sample No. Description Material Location

NESHAP

Classification

Percent/Type

Asbestos Condition

Estimated

Quantity*

1 4-1 Air Cell Pipe Insulation

Interior Pipe Chases;

Steam Pipe Chases

Outside Building

Footprint

Friable 40% Chrysotile Unknown Unknown

11 4-31

12"x12" Beige with Tan

Specks Floor Tile and

Mastic*

12 4-35

12" x 12" Blue with White and Red Specks Floor

Tile and Mastic (Pattern with HA 11)

30 4-92 12"x12" Tri-blue Floor Tile and Mastic

Rm. 008 -

Mechanical Room

Category I

Non-Friable

Floor Tile: None Detected

Mastic: 5% Chrysotile Good

15 4-47 Black Floor Mastic Category I

Non-Friable 5% Chrysotile Good

4-89

4-90

Carpet Glue and Black

Mastic

Category I

Non-Friable

Glue: <1% Chrysotile

(inseparable from mastic)

Mastic: 2% Chrysotile

Good

40 4-122 Black Membrane/Mastic Category I

Non-Friable

Membrane: None Detected

Mastic: 2% Chrysotile Good

42 4-128 Green Ceramic Wall Tile

Mastic and Grout

Category I

Non-Friable

Mastic: 3% Chrysotile

(Contaminated with Mastic from HA 40)

Grout: None Detected

Good

4-146

4-147

4-148

Tan Floor Tile and Mastic 1st Floor Lobby at

Stairs (Bottom Layer)

Category I

Non-Friable

Floor Tile: None Detected

Mastic 1: <1 - 5% Chrysotile Good

50 Square

Feet

39 4-119

12"x12" Tan with Brown

Specks Floor Tile and

Mastic

Room 116 -

Restroom Closet

Category I

Non-Friable

Floor Tile: 2% Chrysotile

Mastic: 2% Chrysotile Good

10 Square

Feet

52 4-158

12"x12" Beige with Brown

Specks Floor Tile and

Mastic

Throughout 2nd Floor Category I

Non-Friable

Floor Tile: <1% Chrysotile

Mastic 1: 3% Chrysotile

Mastic 2: None Detected

Good 4,500 Square

Feet

64 4-196 White Exterior Caulk - at

Brick and Wood

Front Door - Main

Entrance

Category II

Non-Friable 5% Chrysotile Good

10 Square

Feet

HA Sample No. Description Material Location

NESHAP

Classification

Percent/Type

Asbestos Condition

Estimated

Quantity*

Fire Doors Throughout Building Friable Assumed Good Approximately

15 Doors

600 Square

Feet

Terracon Project No. 70207552

Appendix B

MATERIALS CONTAINING ASBESTOS SUMMARY

2300 Ramsey Street

Fayetteville, North Carolina

MATERIALS CONTAINING GREATER THAN 1% ASBESTOS

Fayetteville VAMC - Building 4

ASSUMED ASBESTOS-CONTAINING MATERIALS

N/A

Throughout

Basement

Category I

Non-Friable

Floor Tile: None Detected

Mastic: 5% Chrysotile

(*asbestos-containing mastic associated with HA

12 is assumed to be homogeneous to HA 11;

asbestos-containing mastic may remain in various areas following a previous abatement)

Good

Under Ceramic Floor

Tile and 1st Foot Up from Floor on Wall

Room 009, 012; 1st

Floor North

2,500 Square

Feet

4,500 Square

Feet

B-1

HA Sample No. Description Material Location

NESHAP

Classification

Percent/Type

Asbestos Condition

Estimated

Quantity*

Terracon Project No. 70207552

Appendix B

MATERIALS CONTAINING ASBESTOS SUMMARY

2300 Ramsey Street

Fayetteville, North Carolina

MATERIALS CONTAINING GREATER THAN 1% ASBESTOS

Fayetteville VAMC - Building 4

HA Sample No. Description Material Location

NESHAP

Classification

Percent/Type

Asbestos Condition

Estimated

Quantity*

4 4-10 Window Glazing Crawlspace (remnant

- not installed) N/A <1% Chrysotile Damaged 1 Window

Note: All quantities should be verified by the asbestos abatement contractor.

MATERIALS 1% OR LESS ASBESTOS

B-2

APPENDIX C

ASBESTOS LABORATORY ANALYTICAL REPORT

EMSL Analytical, Inc.

2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560

Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com

292012881EMSL Order:

Customer ID: TITA51

Customer PO: 70207552

Project ID:

Attention: Phone:Cory Edwards (919) 873-2211

Fax:Terracon Consultants, Inc. (919) 873-9555

Received Date:2401 Brentwood Road 12/10/2020 12:51 PM

Analysis Date:Suite 107 12/15/2020 - 12/29/2020

Collected Date:Raleigh, NC 27604

Project: 70207552, VAMC Bldg 4

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

4-1

292012881-0001

40% ChrysotileNon-fibrous (Other)20%Cellulose40%Brown/Gray

Fibrous

Homogeneous

Crawlspace - Air Cell

Pipe Insulation

4-2

292012881-0002

Positive Stop (Not Analyzed)Crawlspace - Air Cell

Pipe Insulation

4-3

292012881-0003

Positive Stop (Not Analyzed)Crawlspace - Air Cell

Pipe Insulation

4-4

292012881-0004

None DetectedNon-fibrous (Other)35%Cellulose65%Brown

Fibrous

Homogeneous

Crawlspace - Felt

Paper

4-5

292012881-0005

None DetectedNon-fibrous (Other)35%Cellulose65%Brown

Fibrous

Homogeneous

Crawlspace - Felt

Paper

4-6

292012881-0006

None DetectedNon-fibrous (Other)35%Cellulose

Synthetic

45%

20%

Black

Fibrous

Homogeneous

Crawlspace - Felt

Paper

4-7

292012881-0007

None DetectedCa Carbonate

Non-fibrous (Other)

5%

95%

Cellulose<1%Black

Non-Fibrous

Homogeneous

Crawlspace - Black

Waterproofing

4-8

292012881-0008

None DetectedCa Carbonate

Non-fibrous (Other)

5%

95%

Cellulose<1%Black

Non-Fibrous

Homogeneous

Crawlspace - Black

Waterproofing

4-9

292012881-0009

None DetectedQuartz

Ca Carbonate

Non-fibrous (Other)

20%

40%

40%

Gray

Non-Fibrous

Homogeneous

Crawlspace - Black

Waterproofing

4-10

292012881-0010

<1% ChrysotileCa Carbonate

Non-fibrous (Other)

25%

75%

Gray

Non-Fibrous

Homogeneous

Crawlspace - Window

Glazing

4-11

292012881-0011

<1% ChrysotileCa Carbonate

Non-fibrous (Other)

25%

75%

Gray

Non-Fibrous

Homogeneous

Crawlspace - Window

Glazing

4-12

292012881-0012

<1% ChrysotileCa Carbonate

Non-fibrous (Other)

25%

75%

Gray

Non-Fibrous

Homogeneous

Crawlspace - Window

Glazing

4-13

292012881-0013

None DetectedCa Carbonate

Non-fibrous (Other)

15%

81%

Wollastonite

Fibrous (Other)

2%

2%

White

Fibrous

Homogeneous

Crawlspace - White

Sealant

4-14

292012881-0014

None DetectedCa Carbonate

Non-fibrous (Other)

15%

81%

Wollastonite

Fibrous (Other)

2%

2%

White

Fibrous

Homogeneous

Crawlspace - White

Sealant

4-15

292012881-0015

None DetectedCa Carbonate

Non-fibrous (Other)

10%

90%

White/Black

Non-Fibrous

Homogeneous

Crawlspace - White

Sealant

4-16-Wrap

292012881-0016

None DetectedCa Carbonate

Non-fibrous (Other)

10%

15%

Cellulose75%White

Fibrous

Homogeneous

Mechanical Room -

Tank - Canvas Wrap over Mud

Initial report from: 12/17/2020 10:35:35

Page 1 of 21ASB_PLM_0008_0001 - 1.78 Printed: 12/29/2020 10:20 AM

Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com

292012881EMSL Order:

Customer ID: TITA51

Customer PO: 70207552

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

4-16-Mud

292012881-0016A

None DetectedCa Carbonate

Non-fibrous (Other)

30%

40%

Min. Wool30%Gray

Fibrous

Homogeneous

Mechanical Room -

Tank - Canvas Wrap over Mud

4-17-Wrap

292012881-0017

None DetectedCa Carbonate

Non-fibrous (Other)

10%

15%

Cellulose75%White

Fibrous

Homogeneous

Mechanical Room -

Tank - Canvas Wrap over Mud

4-17-Mud

292012881-0017A

None DetectedCa Carbonate

Non-fibrous (Other)

30%

40%

Min. Wool30%Gray

Fibrous

Homogeneous

Mechanical Room -

Tank - Canvas Wrap over Mud

4-18-Wrap

292012881-0018

None DetectedCa Carbonate

Non-fibrous (Other)

10%

15%

Cellulose75%Gray

Fibrous

Homogeneous

Mechanical Room -

Tank - Canvas Wrap over Mud

4-18-Mud

292012881-0018A

None DetectedCa Carbonate

Non-fibrous (Other)

40%

25%

Min. Wool35%Gray

Non-Fibrous

Homogeneous

Mechanical Room -

Tank - Canvas Wrap over Mud

4-19

292012881-0019

None DetectedCa Carbonate

Non-fibrous (Other)

25%

73%

Cellulose

Wollastonite

<1%

2%

White

Fibrous

Homogeneous

Mechanical Room -

Fiberglass Duct

Insulation - White

Mastic

4-20

292012881-0020

None DetectedCa Carbonate

Non-fibrous (Other)

25%

73%

Cellulose

Wollastonite

<1%

2%

White

Fibrous

Homogeneous

Mechanical Room -

Fiberglass Duct

Insulation - White

Mastic

4-21

292012881-0021

None DetectedCa Carbonate

Non-fibrous (Other)

10%

86%

Cellulose

Wollastonite

2%

2%

White

Fibrous

Homogeneous

Mechanical Room -

Fiberglass Duct

Insulation - White

Mastic

4-22

292012881-0022

None DetectedPerlite

Non-fibrous (Other)

15%

15%

Cellulose

Min. Wool

30%

40%

Gray/White

Fibrous

Homogeneous

Basement Hallway at

Rm. 002 - 2'x2' White

Ceiling Tile w/Dots &

Small Lines

4-23

292012881-0023

None DetectedPerlite

Non-fibrous (Other)

15%

15%

Cellulose

Min. Wool

30%

40%

Gray/White

Fibrous

Homogeneous

Room 009 - 2'x2'

White Ceiling Tile…