W912QR22R0028_CUI_CF_Plans_Vol4-0002.pdf

PDF 16 MB Posted

Attached to
Renovation of WPAFB Air Force Materiel Command Headquarters; Phase 1
Solicitation number
W912QR22R0028
Issued by

About this file

This solicitation notice provides details for a renovation project at Wright-Patterson Air Force Base in Ohio. The U.S. Army Corps of Engineers Louisville District plans to issue a request for proposal for design and construction services for phase one of the renovation of the Air Force Materiel Command Headquarters building. The scope of work includes repairing and replacing mechanical, electrical and plumbing systems as well as interior renovations across over 60,000 square feet. The contract will be a firm-fixed-price with a duration of approximately three years. Proposals are due through the System for Award Management website by November 2022 and the project value is estimated between $100-250 million. The acquisition will be unrestricted and utilize a best value evaluation methodology.

View the file

Other files

File Type Posted
W912QR22R0028_CUI_CF_Plans-0004.pdf PDF
W912QR22R0028_CUI_CF_Specs-0004.pdf PDF
W912QR22R0028_CUI_CF_Plans-0003.pdf PDF
W912QR22R0028_CUI_CF_Specs-0003.pdf PDF
W912QR22R0028_CUI_CF_CIDV2_FFE-0003.pdf PDF
W912QR22R0028_CUI_CF_Specs_Vol2-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol7-0002.pdf PDF
W912QR22R0028_CUI_CF_Specs_Vol4-0002.pdf PDF
W912QR22R0028_CUI_Pre bid contractors site visit requested photos - 1 Dec 2022.pdf PDF
W912QR22R0028_CUI_CF_Specs_Vol3-0002.pdf PDF
W912QR22R0028_CUI_CF_CIDV2_FFE-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol5-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol3-0002.pdf PDF
W912QR22R0028_CUI_CF_CIDV1_SID-0002.pdf PDF
W912QR22R0028_CUI_CF_Specs_Vol5-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol1-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol6-0002.pdf PDF
W912QR22R0028_CUI_Site Visit Attendee list - AFMC HQ Project 1 DEC 22.pdf PDF
W912QR22R0028_CUI_CF_Specs_Vol1-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol2-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol8-0002.pdf PDF
W912QR22R0028_AFMC_Phase 1_CID_V2_FFE-0001.pdf PDF
JA - AFMC HQ - Reno Trane Chillers - SAM Redacted.pdf PDF
W912QR22R0028_Plans_PH1_Vol8-0000.pdf PDF
W912QR22R0028_Plans_PH1_Vol2-0000.pdf PDF
JA - AFMC HQ Reno - FFE Basis of Design - SAM Redacted.pdf PDF
W912QR22R0028_Specs_PH1_Vol1-0000.pdf PDF
REDACTED - SPE - Signed Class JA for Basis of Design Items.pdf PDF
JA - AFMC HQ Reno - Fire Alarm System - Brand Name - SAM Redacted.pdf PDF
W912QR22R0028_Specs_PH1_Vol2-0000.pdf PDF
W912QR22R0028_Plans_PH1_Vol7-0000.pdf PDF
JA - AFMC HQ Reno - Integrated Sec Platform - Brand Name - SAM Redacted.pdf PDF
W912QR22R0028_Plans_PH1_Vol1-0000.pdf PDF
W912QR22R0028_Specs_PH1_Vol5-0000.pdf PDF
W912QR22R0028_Specs_PH1_Vol4-0000.pdf PDF
W912QR22R0028_Plans_PH1_Vol4-0000.pdf PDF
W912QR22R0028_Plans_PH1_Vol5-0000.pdf PDF
JA - AFMC HQ Reno - Brand Name Siemens Talon or Johnson Controls - SAM Redacted.pdf PDF
W912QR22R0028_Plans_PH1_Vol6-0000.pdf PDF
W912QR22R0028_Plans_PH1_Vol3-0000.pdf PDF
W912QR22R0028_Specs_PH1_Vol3-0000.pdf PDF
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Controlled by: USACE-LRL-ED-MA CUI Category(ies):

LDC or Distribution Statement: N/A POC: Blake Gevedon Contracting Specialist william.b.gevedon@usace.army.mi 502.315.6791

Materials shall be submitted to potential offerors currently certified in the Joint Certification Program (JCP) only.

WRIGHT-PATTERSON AIR

FORCE BASE

STATE ROUTE 444

IN

TE

R

ST

AT

E

INTERSTATE 70

S

TA

TE

R

O U

TE

STATE ROUTE 4

STATE ROUTE 444

T ROAD

A

ST

R

EE

T

OGDEN A

VENUE

C H

ID

LAW

R O

AD

B ROAD

N R

O A D

A STREET

STATE R

OUTE 44

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 2 3 4 5

D

C

B

A

US Army Corps of Engineers ®

P2 NO.:

ISSUE DATE:

VOLUME:

CUI

CUI

C U

I

W R

IG

H

T-

PA

TT

ER

SO

N

A

IR

F O

R C

E

BA

SE

D

AY

TO

N , O

H

IO

R

EP

AI

R

/R

EN

O

VA

TE

A

FM

C

H Q

B U

IL

D

IN

G

(B

2)

P H

AS

E

SOLICITATION NO.:

PHASEREPAIR/RENOVATE AFMC HEADQUARTERS BUILDING

B 10262

W912QR21R0028

CONTROLLED BY: USACE

CONTROLLED BY: LOUISVILLE DISTRICT

CUI CATEGORY: CUI BASIC

DISTRIBUTION/DISSEMINATION CONTROLS: DISTRO C

POC: STEVE SKAGGS, 502-315-6368

B262 PHASE

P2 N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

J.

BE

N

SO

N

PLAN NORTH PLAN NORTHTRUE NORTH TRUE NORTH

G004

VO

LU

M E

-P

H

AS

E

C O

VE

R

S H

EE

T

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

JA

C

O

BS

E N

G

IN

EE

R

IN

G

G R

O U

P

IN

C

H

IG

H

LA

N D

S

PL

AZ

A

D R

IV

E

SU

IT

E

ST

. L O

U

IS

, M O

R .M

ES

SE

L

N .R

EN

D

LE

M

AN

J.

C

O R

SO

N

D

EC

EM

BE

R

B10262 PHASE 1 - CERTIFIED FINAL

LOUISVILLE DISTRICT

475429

05 DECEMBER 2022

FI

R

E

PR

O

TE

C

TI

O N

WRIGHT-PATTERSON AIR FORCE BASE

DAYTON, OHIO 45433

B10262 PHASE 1 - CERTIFIED FINAL

G

EN

E R

AL

FIRE PROTECTION

VICINITY MAP LOCATION MAP

12-08-2022

14 December 2022

W912QR22R0028-0002

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_C U

I_ C

F_ Pl an s_

Vo l4

-0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5

D

C

B

A

CUI

CUI

C U

I

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E D

A Y

T O

N

O H

IO

R E

P A

IR

/R

E N

O V

A T

E A

F M

C H

Q B

U

IL

D

IN

G

B

P

H A

S E

B262 PHASE

P

N O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J

B E

N S

O N

G012

V O

L U

M E

P H

A S

E

S H

E E

T I

N D

E X

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

H

IG

H L

A N

D S

P L

A Z

A D

R

IV

E S

U

IT

E

S T

L

O U

IS

M O

R

M E

S S

E L

N

R E

N D

L E

M A

N

J

C O

R S

O N

D E

C E

M B

E R

B10262 PHASE 1 - CERTIFIED FINAL

F

IR

E P

R O

T E

C T

IO

N

G E

N E

R A

L

FXD110B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 10 - PHASE 1

FXD111B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 11 - PHASE 1

FXD112B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 12 - PHASE 1

FXD100C OVERALL SECOND FLOOR DEMOLITION PLAN - SECOND FLOOR - PHASE 1

FXD101C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 1 - PHASE 1

FXD102C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 2 - PHASE 1

FXD103C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 3 - PHASE 1

FXD104C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 4 - PHASE 1

FXD105C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 5 - PHASE 1

FXD106C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 6 - PHASE 1

FXD107C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 7 - PHASE 1

FXD108C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 8 - PHASE 1

FXD109C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 9 - PHASE 1

FXD110C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 10 - PHASE 1

FXD111C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 11 - PHASE 1

FXD112C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 12 - PHASE 1

FX100A OVERALL BASEMENT PLAN - BASEMENT - PHASE 1

FX101A AREA CEILING PLAN - BASEMENT - AREA 1 - PHASE 1

FX102A AREA CEILING PLAN - BASEMENT - AREA 2 - PHASE 1

FX103A AREA CEILING PLAN - BASEMENT - AREA 3 - PHASE 1

FX104A AREA CEILING PLAN - BASEMENT - AREA 4 - PHASE 1

FX105A AREA CEILING PLAN - BASEMENT - AREA 5 - PHASE 1

FX106A AREA CEILING PLAN - BASEMENT - AREA 6 - PHASE 1

FX107A AREA CEILING PLAN - BASEMENT - AREA 7 - PHASE 1

FX108A AREA CEILING PLAN - BASEMENT - AREA 8 - PHASE 1

FX109A AREA CEILING PLAN - BASEMENT - AREA 9 - PHASE 1

FX110A AREA CEILING PLAN - BASEMENT - AREA 10 - PHASE 1

FX110A-A AREA CEILING PLAN - BASEMENT - AREA 10 - PHASE 1

FX111A AREA CEILING PLAN - BASEMENT - AREA 11 - PHASE 1

FX112A AREA CEILING PLAN - BASEMENT - AREA 12 - PHASE 1

FX100B OVERALL FIRST FLOOR PLAN - FIRST FLOOR - PHASE 1

FX101B AREA CEILING PLAN - FIRST FLOOR - AREA 1 - PHASE 1

FX102B AREA CEILING PLAN - FIRST FLOOR - AREA 2 - PHASE 1

FX103B AREA CEILING PLAN - FIRST FLOOR - AREA 3 - PHASE 1

FX104B AREA CEILING PLAN - FIRST FLOOR - AREA 4 - PHASE 1

FX105B AREA CEILING PLAN - FIRST FLOOR - AREA 5 - PHASE 1

FX106B AREA CEILING PLAN - FIRST FLOOR - AREA 6 - PHASE 1

FX107B AREA CEILING PLAN - FIRST FLOOR - AREA 7 - PHASE 1

FX108B AREA CEILING PLAN - FIRST FLOOR - AREA 8 - PHASE 1

FX109B AREA CEILING PLAN - FIRST FLOOR - AREA 9 - PHASE 1

FX110B AREA CEILING PLAN - FIRST FLOOR - AREA 10 - PHASE 1

FX110B-A AREA CEILING PLAN - FIRST FLOOR - AREA 10 - PHASE 1

FX111B AREA CEILING PLAN - FIRST FLOOR - AREA 11 - PHASE 1

FX112B AREA CEILING PLAN - FIRST FLOOR - AREA 12 - PHASE 1

FX100C OVERALL SECOND FLOOR PLAN - SECOND FLOOR - PHASE 1

FX101C AREA CEILING PLAN - SECOND FLOOR - AREA 1 - PHASE 1

FX102C AREA CEILING PLAN - SECOND FLOOR - AREA 2 - PHASE 1

FX103C AREA CEILING PLAN - SECOND FLOOR - AREA 3 - PHASE 1

FX104C AREA CEILING PLAN - SECOND FLOOR - AREA 4 - PHASE 1

FX105C AREA CEILING PLAN - SECOND FLOOR - AREA 5 - PHASE 1

FX106C AREA CEILING PLAN - SECOND FLOOR - AREA 6 - PHASE 1

FX107C AREA CEILING PLAN - SECOND FLOOR - AREA 7 - PHASE 1

FX108C AREA CEILING PLAN - SECOND FLOOR - AREA 8 - PHASE 1

FX109C AREA CEILING PLAN - SECOND FLOOR - AREA 9 - PHASE 1

FX110C AREA CEILING PLAN - SECOND FLOOR - AREA 10 - PHASE 1

FX111C AREA CEILING PLAN - SECOND FLOOR - AREA 11 - PHASE 1

FX112C AREA CEILING PLAN - SECOND FLOOR - AREA 12 - PHASE 1

FX500 FIRE SUPPRESSION DETAILS - PHASE 1

FX501 FIRE SUPPRESSION DETAILS - PHASE 1

FX502 FIRE SUPPRESSION DETAILS - PHASE 1

FX503 FIRE SUPPRESSION DETAILS - PHASE 1

FX504 STANDPIPE RISER SCHEMATIC - PHASE 1

FA001 FIRE ALARM AND MASS NOTIFICATION GENERAL NOTES,SYMBOLS, AND

ABBREVIATIONS - PHASE 1 -

FAD100A OVERALL BASEMENT DEMOLITION PLAN - BASEMENT - PHASE 1

FAD101A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 1 - PHASE 1

FAD102A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 2 - PHASE 1

FAD103A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 3 - PHASE 1

FAD104A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 4 - PHASE 1

FAD105A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 5 - PHASE 1

FAD106A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 6 - PHASE 1

FAD107A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 7 - PHASE 1

FAD108A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 8 - PHASE 1

FAD109A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 9 - PHASE 1

FAD110A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 10 -PHASE 1

FAD111A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 11 - PHASE 1

FAD112A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 12 - PACKAGE A

FAD100B OVERALL FIRST FLOOR DEMOLITION PLAN - FIRST FLOOR - PHASE 1

FAD101B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 1 - PHASE 1

FAD102B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 2 - PHASE 1

FAD103B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 3 - PHASE 1

FAD104B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 4 - PHASE 1

FAD105B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 5 - PHASE 1

FAD106B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 6 - PHASE 1

FAD107B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 7 - PHASE 1

FAD108B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 8 - PHASE 1

FAD109B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 9 - PHASE 1

FAD110B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 10 -PHASE 1

FAD111B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 11 - PHASE 1

FAD112B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 12 - PHASE 1

FAD100C OVERALL SECOND FLOOR DEMOLITON PLAN - SECOND FLOOR - PHASE 1

FAD101C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 1 - PHASE 1

FAD102C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 2 - PHASE 1

FAD103C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 3 - PHASE 1

FAD104C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 4 - PHASE 1

FAD105C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 5 PHASE 1

FAD106C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 6 - PHASE 1

FAD107C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 7 - PHASE 1

FAD108C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 8 - PHASE 1

FAD109C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 9 - PHASE 1

FAD110C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 10 - PHASE 1

FAD111C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 11 - PHASE 1

FAD112C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 12 -PHASE 1

FA100A OVERALL BASEMENT PLAN - BASEMENT - PHASE 1

FA101A AREA CEILING PLAN - BASEMENT - AREA 1 - PHASE 1

FA102A AREA CEILING PLAN - BASEMENT - AREA 2 - PHASE 1

FA103A AREA CEILING PLAN - BASEMENT - AREA 3 - PHASE 1

FA104A AREA CEILING PLAN - BASEMENT - AREA 4 - PHASE 1

FA105A AREA CEILING PLAN - BASEMENT - AREA 5 - PHASE 1

FA106A AREA CEILING PLAN - BASEMENT - AREA 6 - PHASE 1

FA107A AREA CEILING PLAN - BASEMENT - AREA 7 - PHASE 1

FA108A AREA CEILING PLAN - BASEMENT - AREA 8 - PHASE 1

FA109A AREA CEILING PLAN - BASEMENT - AREA 9 - PHASE 1

FA110A AREA CEILING PLAN - BASEMENT - AREA 10 - PHASE 1

FA110A-A AREA CEILING PLAN - BASEMENT - AREA 10 - PHASE 1

FA111A AREA CEILING PLAN - BASEMENT - AREA 11 - PHASE 1

FA112A AREA CEILING PLAN - BASEMENT - AREA 12 - PHASE 1

FA100B OVERALL FIRST FLOOR PLAN - FIRST FLOOR - PHASE 1

FA101B AREA CEILING PLAN - FIRST FLOOR - AREA 1 - PHASE 1

FA102B AREA CEILING PLAN - FIRST FLOOR - AREA 2 - PHASE 1

FA103B AREA CEILING PLAN - FIRST FLOOR - AREA 3 - PHASE 1

FA104B AREA CEILING PLAN - FIRST FLOOR - AREA 4 - PHASE 1

FA105B AREA CEILING PLAN - FIRST FLOOR - AREA 5 - PHASE 1

FA106B AREA CEILING PLAN - FIRST FLOOR - AREA 6 - PHASE 1

FA107B AREA CEILING PLAN - FIRST FLOOR - AREA 7 - PHASE 1

FA108B AREA CEILING PLAN - FIRST FLOOR - AREA 8 - PHASE 1

FA109B AREA CEILING PLAN - FIRST FLOOR - AREA 9 - PHASE 1

FA110B AREA CEILING PLAN - FIRST FLOOR - AREA 10 - PHASE 1

FA110B-A AREA CEILING PLAN - FIRST FLOOR - AREA 10 - PHASE 1

FA111B AREA CEILING PLAN - FIRST FLOOR - AREA 11 - PHASE 1

FA112B AREA CEILING PLAN - FIRST FLOOR - AREA 12 - PHASE 1

FA100C OVERALL SECOND FLOOR PLAN - SECOND FLOOR - PHASE 1

FA101C AREA CEILING PLAN - SECOND FLOOR - AREA 1 - PHASE 1

FA102C AREA CEILING PLAN - SECOND FLOOR - AREA 2 - PHASE 1

FA103C AREA CEILING PLAN - SECOND FLOOR - AREA 3 - PHASE 1

FA104C AREA CEILING PLAN - SECOND FLOOR - AREA 4 - PHASE 1

FA105C AREA CEILING PLAN - SECOND FLOOR - AREA 5 - PHASE 1

FA106C AREA CEILING PLAN - SECOND FLOOR - AREA 6 - PHASE 1

FA107C AREA CEILING PLAN - SECOND FLOOR - AREA 7 - PHASE 1

FA108C AREA CEILING PLAN - SECOND FLOOR - AREA 8 - PHASE 1

FA109C AREA CEILING PLAN - SECOND FLOOR - AREA 9 - PHASE 1

FA110C AREA CEILING PLAN - SECOND FLOOR - AREA 10 - PHASE 1

FA111C AREA CEILING PLAN - SECOND FLOOR - AREA 11 - PHASE 1

FA112C AREA CEILING PLAN - SECOND FLOOR - AREA 12 - PHASE 1

FA500 FIRE ALARM AND MASS NOTIFICATION DETAILS - PHASE 1

FA501 FIRE ALARM AND MASS NOTIFICATION DETAILS - PHASE 1

FA502 FIRE ALARM AND MASS NOTIFICATION MATRIX OF OPERATIONS - PHASE 1 -

FX001 FIRE SUPPRESSION GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS -

PHASE 1 -

FXD100A OVERALL BASEMENT DEMOLITION PLAN - BASEMENT - PHASE 1

FXD101A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 1 -PHASE 1

FXD102A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 2 - PHASE 1

FXD103A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 3 - PHASE 1

FXD104A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 4 - PHASE 1

FXD105A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 5 - PHASE 1

FXD106A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 6 - PHASE 1

FXD107A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 7 - PHASE 1

FXD108A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 8 - PHASE 1

FXD109A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 9 - PHASE 1

FXD110A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 10 - PHASE 1

FXD111A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 11 - PHASE 1

FXD112A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 12 -PHASE 1

FXD100B OVERALL FIRST FLOOR DEMOLITION PLAN - FIRST FLOOR - PACKAGE A

FXD101B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 1 - PHASE 1

FXD102B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 2 - PHASE 1

FXD103B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 3 - PHASE 1

FXD104B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 4 - PHASE 1

FXD105B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 5 - PHASE 1

FXD106B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 6 - PHASE 1

FXD107B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 7 - PHASE 1

FXD108B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 8 - PHASE 1

FXD109B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 9 - PHASE 1

FIRE PROTECTION SHEET INDEXGENERAL SHEET INDEX

G004 VOLUME 4 - PHASE 1 COVER SHEET - FIRE PROTECTION

G012 VOLUME 4 - PHASE 1 SHEET INDEX - FIRE PROTECTION

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_C U

I_ C

F_ Pl an s_

Vo l4

-0

10" ELECTRIC BELL

OMNI-DIRECTIONAL FIRE ALARM ANTENNA

"WP"

GENERAL NOTES AND SYMBOLS

XX, C

FIRE ALARM AND MASS NOTIFICATION HORN/STROBE

(XX DENOTES MINIMUM CANDELA RATING)

(C DENOTES CEILING MOUNTED)XX, C

FIRE ALARM AND MASS NOTIFICATION SYMBOLS

FIRE ALARM AND MASS NOTIFICATION STROBE

(XX DENOTES MINIMUM CANDELA RATING)

(C DENOTES CEILING MOUNTED)

FMCP

(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)

LCD ANNUNCIATOR PANEL

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

P.

Q.

R.

S.

THE FIRE ALARM/MASS NOTIFICATION SYSTEM MUST BE DESIGNED, INSTALLED, AND

COMMISSIONED IN ACCORDANCE WITH THE FOLLOW ING:

- NFPA 72 (2019 EDITION)

- UFC 3-600-01 (CHANGE 4, FEBRUARY 2020)

- UFC 4-010-01 (DECEMBER 2018)

- UFC 4-021-01 (CHANGE 1, JANUARY 2010)

- ECB 2018-17

NOTE: SEE SHEET E001 FOR APPLICABLE ELECTRICAL CODES AND

REGULATIONS

THESE DOCUMENTS DEPICT A PERFORMANCE LEVEL ENGINEERING DESIGN

LAYOUT TO BE UTILIZED AS GUIDANCE FOR THE PLANNING OF THE SYSTEM BY THE

CONTRACTOR. PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL

FROM THE ENGINEER OF RECORD AND THE AUTHORITY HAVING JURISDICTION

PRIOR TO INSTALLATION. INCLUDE IN THE SHOP DRAWINGS AND CALCULATIONS

ANY ADDITIONAL EQUIPMENT NECESSARY, INCLUDING INITIATING DEVICES AND

NOTIFICATION APPLIANCES, TO PROVIDE A COMPLETE INSTALLATION AND COMPLY

WITH LOCAL CODES, AMENDMENTS AND BASE STANDARDS.

FOR COMPLETE SYSTEM CONTROL, REFER TO SPECIFICATION SECTION 28 31 76

AND THE MATRIX OF OPERATIONS WITHIN THIS PHASE.

PROVIDE AN ADDRESSABLE FIRE ALARM/MASS NOTIFICATION SYSTEM CONTROL

PANEL. SYSTEM MUST BE NETWORKED INTO THE EXISTING SIMPLEX MODEL 4100

FMCP CURRENTLY IN THE BUILDING AND THE EXISTING BASEWIDE FIRE ALARM

SYSTEM NETWORK.

THE FLASH RATE OF VISIBLE NOTIFICATION APPLIANCES MUST NOT EXCEED 2

FLASHES PER SECOND, NOR BE LESS THAN 1 FLASH EVERY SECOND, IN

ACCORDANCE WITH NFPA 72. A MAXIMUM PULSE DURATION MUST BE 0.2 SECONDS

WITH A MAXIMUM DUTY CYCLE OF 40%, IN ACCORDANCE W ITH NFPA 72. VISIBLE

NOTIFICATION APPLIANCES MUST BE SPACED IN ACCORDANCE WITH NFPA 72.

STROBES MUST BE SYNCHRONIZED.

AUDIBLE FIRE ALARM SOUND LEVELS MUST BE AT LEAST 15 dBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 dBA ABOVE THE MAXIMUM SOUND LEVEL

HAVING A DURATION OF AT LEAST 60 SECONDS, WHICHEVER IS GREATER,

MEASURED 5 FEET ABOVE THE FLOOR IN THE OCCUPIABLE AREA, BUT NOT

GREATER THAN 120 dBA AT THE MINIMUM HEARING DISTANCE FROM THE AUDILE

APPLIANCE.

PROVIDE ADEQUATE NOTIFICATION APPLIANCES THROUGHOUT THE FACILITY TO

MEET THE UFC 3-600-01 REQUIREMENTS.

SPRINKLER SYSTEM TAMPER AND FLOW SWITCHES MUST BE INSTALLED UNDER

SPECIFICATION SECTION 21 13 13.00 10. CONNECT DEVICES TO THE FIRE ALARM

SIGNALING LINE CIRCUITS.

OBTAIN APPROVALS FROM THE FPDOR AND AHJ PRIOR TO COMMENCING WORK.

DO NOT LOCATE DETECTORS IN DIRECT AIR OR CLOSER THAN 3 FEET FROM AN AIR

SUPPLY OR RETURN DIFFUSER.

MOUNT ALL WALL-MOUNTED VISUAL AND VISUAL/AUDIBLE NOTIFICATION

APPLIANCES WITH THE ENTIRE STROBE LENS BETWEEN 80" TO 96" ABOVE THE

FINISHED FLOOR.

FIRE ALARM SIGNALING LINE CIRCUITS (SLC) AND NOTIFICATION APPLIANCE

CIRCUITS (NAC) ARE TO BE CLASS B. T-TAPS, WIRE NUTS, AND/OR PIG TAILS ARE

NOT PERMITTED.

THE CONTRACTOR MUST SPACE SPEAKERS TO PROVIDE A COMMON

INTELLIGIBILITY SCALE (CIS) SCORE THAT MEETS THE MINIMUM INTENT OF UFC

4-021-01. THE INSTALLING CONTRACTOR MUST VERIFY THEIR DESIGN MEETS THIS

INTENT BY PROVIDING SPEECH INTELLIGIBILITY CALCULATIONS BASED ON THE

INSTALLED PRODUCTS' THEORETICAL Q AND DIRECTIVITY INDEX. TO CONFIRM

INTELLGIBILITY, SPEAKERS MUST TESTED AND ADDED TO MEET REQUIREMENTS.

SPEAKERS MUST NOT BE LOCATED ADJACENT TO LOCS. MINIMUM CIS VALUE IN

EACH AREA WHERE OCCUPANTS ARE TYPICALLY LOCATED IS 0.8.

FIRE ALARM ZONES MUST COINCIDE WITH FIRE SPRINKLER ZONES.

QUALIFIED FIRE PROTECTION ENGINEER (QFPE) MUST REVIEW DOCUMENTS AND

SHOP DRAWINGS MUST BEAR THE REVIEW STAMP OF THE QFPE PRIOR TO

SUBMITTING TO THE DESIGNATED FIRE PROTECTION ENGINEER (DFPE).

SYSTEM SHUTDOWNS MUST BE KEPT TO A MINIMUM AND ARE TO OCCUR AFTER

NORMAL BUSINESS HOURS. RECONFIGURATION OF EXISTING CIRCUITS AND WIRING

MUST BE ACCOMPLISHED BY INSTALLING ALL NEW CIRCUITS AND WIRING PRIOR TO

THE FINAL CONNECTIONS. SHUTDOWNS OF THE FIRE ALARM SYSTEMS WILL ONLY

BE ALLOWED ONCE THE NEW CIRCUITS AND WIRING IS READY IN ALL RESPECTS

FOR FINAL CONNECTIONS.

DEACTIVATION, RELOCATION, AND NEW WORK MUST BE PLANNED TO MINIMIZE

DISRUPTION OF BASE OFFICE FUNCTIONS. PROVIDE TEMPORARY CAPPING AND

CONNECTIONS AS REQUIRED TO MAINTAIN EXISTING SYSTEMS DURING

CONSTRUCTION. COORDINATE ALL SHUTDOWNS WITH CONTRACTING OFFICER

GROUP.

THE CONTRACTOR MUST PROVIDE A FIRE W ATCH PATROL IN COMPLIANCE WITH

WRIGHT PATTERSON AFB 32-2001 WITH ASSOCIATED ATTACHMENTS, UFC 3-601-02,

NFPA 1 AND NFPA 241 FOR ALL AREAS DURING ALL TIMES WHENEVER THE FIRE

ALARM SYSTEM OR FIRE SPRINKLER SYSTEMS IN THE OCCUPIED AREAS OF THE

BUILDING ARE INOPERABLE. THE CONTRACTOR MUST ALSO PROVIDE A FIRE

WATCH PATROL FOR CONSTRUCTION AREAS AT ALL TIMES WHEN CONSTRUCTION

AND DEMOLITION OPERATIONS ARE NOT IN PROGRESS. WP AFB FIRE PREVENTION

MUST BE NOTIFIED BY THE CONTRACTOR ANY TIME A FIRE PROTECTION/DETECTION

SYSTEM OR LIFE SAFETY COMPONENT IS IMPAIRED. FIRE WATCH PATROL GUARDS

MUST PATROL ALL PARTS OF THE BUILDING, AND OUTSIDE AREAS WHERE

HAZARDOUS EQUIPMENT OR MATERIALS ARE LOCATED. ROUNDS MUST BE

CONDUCTED EVERY ½-HOUR FOR 2-HOURS AFTER SUSPENSION OF WORK FOR THE

DAY AND EVERY HOUR THEREAFTER DURING NONWORKING HOURS AND MUST

INCLUDE TOURS OF ACCESSIBLE WORK AREAS. THE CONTRACTOR MUST

COORDINATE WITH THE BUILDING MANAGEMENT TO ARRANGE FOR SIMILAR FIRE

WATCH PATROLS FOR SECURED AND CLASSIFIED AREAS WHICH ARE NOT

ACCESSIBLE TO THE CONTRACTOR. FIRE WATCH PERSONNEL MUST BE TRAINED IN

THE FOLLOWING, NOTIFICATION PROCEDURES THAT INCLUDE CALLING THE FIRE

DEPARTMENT AND MANAGEMENT PERSONNEL, FUNCTION AND OPERATION OF FIRE

PROTECTION EQUIPMENT, FAMILIARIZATION WITH FIRE HAZARDS, AND USE OF

CONSTRUCTION ELEVATORS, WHERE PROVIDED.

PROVIDE TEMPORARY, NONRESETABLE, HEAT DETECTORS AS REQUIRED TO

ACHIEVE THE COVERAGE INDICATED WHILE THE SPRINKLER SYSTEM IS OUT OF

OPERATION. SPACE HEAT DETECTORS IN ACCORDANCE WITH CRITERIA OUTLINED

IN NFPA 72. PROVIDE A MINIMUM OF ONE HEAT DETECTOR PER ROOM WITHIN THE

AREA INDICATED. RELOCATE HEAT DETECTORS AS NECESSARY DURING

CONSTRUCTION BASED ON CHANGES TO CEILING STRUCTURE (EXISTING CEILING,

STRUCTURAL DECK, NEW CEILING) TO PROVIDE COVERAGE AT THE HIGHEST

EXPOSED ELEVATION THROUGHOUT CONSTRUCTION. CIRCUITING FOR TEMPORARY

HEAT DETECTION IS NOT REQUIRED TO BE LOCATED IN CONDUIT UNLESS SUBJECT

TO MECHANICAL DAMAGE. UPON COMPLETION OF FIRE SUPPRESSION WORK,

REMOVE HEAT DETECTORS, CIRCUITING, AND ADDRESSABLE MODULES AND TURN

OVER TO THE GOVERNMENT.

UL LISTED FIRE ALARM AND MASS NOTIFICATION CONTROL PANEL

VISUAL TEXT DISPLAY

ANN

VTD

MM ADDRESSABLE MONITOR MODULE

SMOKE DETECTOR (P - PHOTOELECTRIC, E - ELEVATOR)

NOTIFICATION APPLIANCE CIRCUIT REMOTE POWER SUPPLYNAC

ADDRESSABLE CONTROL MODULE

F DOUBLE ACTION MANUAL FIRE ALARM PULL STATION

CM

DUCT SMOKE DETECTOR (S - SUPPLY; R - RETURN)

S, R

FIRE ALARM AND MASS NOTIFICATION SPEAKER

(WP DENOTES WEATHER PROOF)

(C DENOTES CEILING MOUNTED)

MISCELLANEOUS

FIRE ALARM AND MASS NOTIFICATION NOTES

SS SURGE SUPPRESSOR

DESIGNATES WEATHERPROOF BACKBOX AND DEVICE

HEAT DETECTOR

(XX DENOTES TEMPERATURE RATING IN FARENHEIT)

(WP DENOTES WEATHERPROOF)

H

NOTE: HALFTONED COLORING DENOTES DEVICES TO BE DEMOLISHED.

WALL MOUNTED OPTICAL FLAME DETECTOR - INFRARED

P PRESSURE SWITCH WITH ADDRESSABLE MONITOR MODULE

SUPERVISORY VALVE TAMPER SWITCH WITH ADDRESSABLE MONITOR MODULE

WATER FLOW SWITCH WITH ADDRESSABLE MONITOR MODULE

CARBON MONOXIDE DETECTOR

FIRE ALARM AND MASS NOTIFICATION SPEAKER/STROBE

(XX DENOTES MINIMUM CANDELA RATING)

(C DENOTES CEILING MOUNTED)XX, C

DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS, NOTIFICATION APPLIANCES, CONDUIT, CIRCUITS, AND INTERFACE MODULES WITHIN THE SELECTIVE PHASE UNLESS OTHERWISE INDICATED. FULL-TONE SYMBOLS REPRESENT EXISTING DEVICES BEING DEMOLISHED IN THE PHASE. SIGNALING LINE AND NOTIFICATION APPLIANCE CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY. FIRE ALARM EQUIPMENT, PANELS THAT POWER THE FIRE ALARM EQUIPMENT, AND CONDUIT NOT

WITHIN THE PHASE 1 AREA OF WORK MUST REMAIN FULLY OPERATIONAL DURING PHASE 1.

MATERIALS FROM THE DEMOLITION WORK FOR THE EXISTING FIRE ALARM SYSTEM MUST BE REMOVED FROM SITE (UNLESS NOTED OTHERWISE) AND DISPOSED OF IN ACCORDANCE WITH THE APPLICABLE ENVIRONMENTAL PROTECTION AGENCY AND STATE CODES, REGULATIONS AND AS DIRECTED BY COTR. CLEAN-UP MUST BE DAILY OR

AS DIRECTED BY COTR.

EXISTING W ALL PENETRATIONS THAT ARE NOT REUSED MUST BE REPAIRED TO MATCH EXISTING BUILDING FINISHES. FIRE STOPPED PENETRATIONS WHERE EXISTING CONDUIT MUST BE REMOVED AND MUST BE REPAIRED

TO MAINTAIN BUILDING FIRE INTEGRITY.

CONTRACTOR MUST DEMOLISH ALL ABANDONED IN PLACE FIRE ALARM EQUIPMENT FROM THE BUILDING WITHIN THE

SCOPE AREA.

FIRE ALARM AND MASS NOTIFICATION DEMOLITION NOTES

A.

B.

C.

D.

GAP GRAPHIC ANNUNCIATOR PANEL

WP, C

P, E

CO

RAT RADIO ALARM TRANSMITTER

WF

C

TS

C

ASSD AIR SAMPLING SMOKE DETECTOR PANEL

NOTIFICATION APPLIANCE REQUIREMENTS TABLE

IM ISOLATION MODULE

C FIRE ALARM/MASS NOTIFICATION PANEL DOCUMENTS CABINET

DH DOOR HOLDER

FACP UL LISTED FIRE ALARM CONTROL PANEL

LOC RADIO ALARM TRANSMITTER

ABBREVIATIONS

ACU

AFF

AHJ

AVG

CO

COTR

ELEV

EOL

FPC

FPDOR

LOC

MIN

NAC

NIC

NP

NC

QFPE

SLC

SQFT

VEWFD

WP

AUTONOMOUS CONTROL UNIT

ABOVE FINISHED FLOOR

AUTHORITY HAVING JURISDICTION

AVERAGE

CONTRACTING OFFICER

CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE

ELEVATION

END OF LINE RESISTOR

FIRE PUMP CONTROLLER

FIRE PROTECTION DESIGNER OF RECORD

LOCAL OPERATING CONSOLE

MINIMUM

NOTIFICATION APPLIANCE CIRCUIT

NOT IN CONTRACT

NOT PERMITTED

NONCOMBUSTIBLE

QUALIFIED FIRE PROTECTION ENGINEER

SIGNALING LINE CIRCUIT

SQUARE FEET

VERY EARLY WARNING FIRE DETECTION

WEATHER PROOF

POINT OF NEW CONNECTION TO EXISTING PIPING

POINT OF DISCONNECTION

2-HOUR FIRE RATED CONSTRUCTION BARRIER

REMOVE 2-HOUR CONSTRUCTION BARRIER

FIRE ALARM ZONE BOUNDARY LINE

CONCRETE MASONRY UNIT

PHASE BOUNDARY LINE

INSTALL TERMINAL CABINETS, JUNCTION BOXES, CONDUIT, WIRING ETC. TO ALLOW FOR

TRANSFER OF CIRCUITS FROM PRESENT MAIN FIRE ALARM CONTROL PANEL (FACP) TO

LOCATION WHERE MAIN FACP WILL BE REINSTALLED.

MODIFY EXISTING CIRCUITS THAT CROSS THE CONSTRUCTION BARRIERS ON THE NORTH SIDE

OF FIRST FLOOR, THE MAIN ELECTRICAL ROOM AND A-SWITCH ROOM IN THE BASEMENT AND

THE OFFICE SPACES ON FIRST ANDSECOND FLOOR. THE INTENT IS TO MAINTAIN THE

OPERATION OF THESE CIRCUITS AND FIRE ALARM SYSTEMS FOR THE OCCUPIED NON-

CONSTRUCTION SIDE OF THE CONSTRUCTION BARRIER. MAINTAIN MANUAL PULL STATIONS

AND CIRCUITS AT THE ENTRANCES TO STAIRS, 4 AND 6 ON FIRST AND SECOND FLOOR AND THE

EXITS FROM THE OFFICES.

DEMOLISH FIRE ALARM DEVICES, CONDUIT, WIRING, ETC. IN THESE SAME AREAS.

ADD, RELOCATE, DEMOLISH EXISTING DEVICES IN OTHER AREAS OF CONSTRUCTION TO

MAINTAIN EQUIVALENT LEVELS OF FIRE ALARM COVERAGE.

RELOCATE THE MAIN FACP OUTSIDE OF THE CONSTRUCTION BARRIER OF THE OFFICES ON THE

FIRST FLOOR. MAINTAIN FULL OPERATION OF THE FACP WITH MINIMAL DISRUPTION. PROVIDE

FIRE WATCH AS INDICATED IN THE DESIGN DOCUMENTS.

INSTALL NEW MAIN FACP ON THE FIRST FLOOR OFFICES AS INDICATED IN THE DESIGN

DOCUMENTS. INSTALL NEW CIRCUITS, CONDUIT, WIRING, ETC. AND INSTALL NEW NOTIFICATION

APPLIANCES AND INITIATION DEVICES FOR THE RENOVATED AREAS OF THE NORTH SIDE OF

THE FIRST FLOOR, THE MAIN ELECTRICAL ROOM, A-SW ITCH ROOM AND FIRE PUMP ROOM IN

THE BASEMENT AND THE FIRST AND SECOND FLOOR OFFICES.

INTERFACE THE ORIGINAL FACP WITH THE NEW FACP FOR MUTUAL NOTIFICATION OF ALARM

SIGNALS. CONNECT THE NEW FACP TO THE BASE REPORTING SYSTEM.

SEQUENCING INFORMATION

A.

B.

C.

D.

E.

F.

G.

XX, WP

K KNOX BOX

ROOM TYPE VISUAL NOTIFICATION

REQUIRED

INTELLIGIBILITY

REQUIRED

DESIGN AMBIENT

SOUND LEVEL

OPEN OFFICE Y Y 69

PRIVATE OFFICE/RECEIVING OFFICE Y Y 69

ELECTRICAL/A-SWITCH TELCO RACKS Y Y 45

VESTIBULE Y Y 69

FIRE PUMP Y Y 45

REFERENCES:

- UFC 3-600-01 (9-18.6.3) FOR VISUAL NOTIFICATION REQUIREMENTS

- UFC 4-021-01 (4-6.1.2) FOR INTELLIGIBILITY REQUIREMENTS

- NFPA 72 (18.4.11.3) FOR DESIGN SOUND AMBIENT LEVEL

STAIRS/ELEVATOR SHAFTS/CHASES N N N/A

PLUMBING EQUIPMENT Y Y 45

MEN/WOMEN RESTROOM Y Y 69

CUSTODIAL N Y 45

STORAGE Y Y 45

RECEPTION/WAITING Y Y 69

CORRIDOR Y Y 69

COLLABORATION Y Y 75

TELECOMMUNICATIONS Y Y 45

CONFERENCE ROOM Y Y 75

COPY/COFFEE Y Y 75

NURSING Y Y 69

FOOD VENUE Y Y 75

UNISEX/LOCKERS Y Y 69

WASTE & RECYCLING Y Y 45

BARBER SHOP Y Y 69

GOODWILL Y Y 55

STAGING Y Y 45

DINING Y Y 75

LOBBY/GUARD DESK Y Y 69

CREDIT UNION Y Y 69

DRY CLEANER Y Y 69

NORTH BRIDGE Y Y 69

EXPRESS/CIRCULATION Y Y 75

NOTE: IF ROOM IS NOT IN ABOVE LIST, USE THE BELOW CODES AND STANDARDS TO DETERMINE THE VISUAL NOTIFICATION REQUIREMENTS, INTELLIGIBILITY REQUIREMENTS, AND THE DESIGN SOUND AMBIENT LEVEL.

NOTE: SPEAKERS MUST NOT BE LOCATED ADJACENT TO LOC'S. SEE UFC 4-021-01 FOR LOC REQUIREMENTS.

NOTE: PROVIDE WEATHERPROOF SPEAKERS AT EVERY EXIT DOOR IN ACCORDANCE WITH UFC 4-021-01.

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 2 3 4 5

D

C

B

A

CUI

CUI

C U

I

W R

IG

H

T-

PA

TT

ER

SO

N

A

IR

F O

R C

E

BA

SE

D

AY

TO

N , O

H

IO

R

EP

AI

R

/R

EN

O

VA

TE

A

FM

C

H Q

B U

IL

D

IN

G

(B

2)

P H

AS

E

B262 PHASE

P2 N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

J.

B

EN

SO

N

FA001

FI

R

E

AL

AR

M

A N

D M

AS

S

N O

TI

FI

C

AT

IO

N

G

EN

ER

AL

N O

TE

S, SY

M

BO

LS

, A N

D A

BB

R

EV

IA

TI

O

N S

-P H

AS

E

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

JA

C

O

BS

E N

G

IN

EE

R

IN

G

G R

O U

P

IN

C

H

IG

H

LA

N D

S

PL

AZ

A

D R

IV

E

SU

IT

E

ST

. L O

U

IS

, M O

J.

A.

B

EA

LS

S.

S.

R O

D R

IG

U

EZ

C .W

. K R

IE

BE

L

D

EC

EM

BE

R

B10262 PHASE 1 - CERTIFIED FINAL

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_C U

I_ C

F_ Pl an s_

Vo l4

-0

T

S

R

Q

P

O

N

M

L

K

J

I

H

G

F

E

D

C

A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 19 20 21 22 23 24 2517 23E22E

1-J

1-17

1-16

1-15

1-14

1-13.5

1-13

1-12

BUILDING NOT IN SCOPE

B

1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION

GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS.

NOTE: SHADED AREA IS NOT UNDER CURRENT CONSTRUCTION PHASE

UNLESS NOTED OTHERWISE - WORK TO BE PERFORMED IN THE

SHADED AREAS MUST BE COORDINATED WITH COR FOUR WEEKS

PRIOR TO MINIMIZE MISSION IMPACT.

GENERAL NOTES - DEMOLITION KEYED NOTES - DEMOLITION

1. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES

WITHIN THE AREA OF WORK AS NECESSARY TO ACCOMMODATE

NEW LAYOUT.

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 2 3 4 5

D

C

B

A

CUI

CUI

C U

I

W R

IG

H

T-

PA

TT

ER

SO

N

A

IR

F O

R C

E

BA

SE

D

AY

TO

N , O

H

IO

R

EP

AI

R

/R

EN

O

VA

TE

A

FM

C

H Q

B U

IL

D

IN

G

(B

2)

P H

AS

E

B262 PHASE

P2 N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

J.

B

EN

SO

N

FAD100A

O

VE

R

AL

L

BA

SE

M

EN

T

D

EM

O

LI

TI

O

N P

LA

N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

JA

C

O

BS

E N

G

IN

EE

R

IN

G

G R

O U

P

IN

C

H

IG

H

LA

N D

S

PL

AZ

A

D R

IV

E

SU

IT

E

ST

. L O

U

IS

, M O

J.

A.

B

EA

LS

S.

S.

R O

D R

IG

U

EZ

C .W

. K R

IE

BE

L

D

EC

EM

BE

R

B10262 PHASE 1 - CERTIFIED FINAL

BA

SE

M

EN

T -P

H

AS

E

FI

R

E P

R O

TE

C

TI

O

N D

EM

O

LI

TI

O N

1/32" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION OVERALL BASEMENT DEMOLITION PLAN N

0 32'16' 64'

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_C U

I_ C

F_ Pl an s_

Vo l4

-0

M

G

F

E

D

C

A

18 19 20 21 22 23 24 2523E22E

MA

TC

HL

IN

E

A1

FA

D1

A

MATCHLINE

A1 FAD102A

WF

C

TS

C

(2

A-SW ITCH TELCO RACKS

ELECTRICAL

B

1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL

NOTES, SYMBOLS, AMD ABBREVIATIONS.

2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,

NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED

CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED

ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE

CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE

THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.

3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT

MANAGER AND THE WRITTEN APPROVAL OF USACE.

4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND

NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE

FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.

THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.

5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING

CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR

GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING

CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE

FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO

FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE

DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE

CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN

WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.

COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND

REMOTE PANELS WITH TECHNICIAN.

NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT

EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT

UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -

WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED

WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.

GENERAL NOTES - DEMOLITION W ORK

1. EXISTING MONITOR MODULES, TAMPER SWITCH, AND FLOW SWITCH TO BE

DEMOLISHED.

2. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES WITHIN

THE AREA OF WORK AS NESCESSARY TO ACCOMMODATE NEW LAYOUT.

KEYED NOTES - DEMOLITION W ORK

KEY PLAN

N

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 2 3 4 5

D

C

B

A

8'4' 16'

CUI

CUI

C U

I

W R

IG

H

T-

PA

TT

ER

SO

N

A

IR

F O

R C

E

BA

SE

D

AY

TO

N , O

H

IO

R

EP

AI

R

/R

EN

O

VA

TE

A

FM

C

H Q

B U

IL

D

IN

G

(B

2)

P H

AS

E

B262 PHASE

P2 N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

J.

B

EN

SO

N

FAD101A

AR

EA

D

EM

O

LI

TI

O

N C

EI

LI

N G

P

LA

N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

JA

C

O

BS

E N

G

IN

EE

R

IN

G

G R

O U

P

IN

C

H

IG

H

LA

N D

S

PL

AZ

A

D R

IV

E

SU

IT

E

ST

. L O

U

IS

, M O

J.

A.

B

EA

LS

S.

S.

R O

D R

IG

U

EZ

C .W

. K R

IE

BE

L

D

EC

EM

BE

R

B10262 PHASE 1 - CERTIFIED FINAL

BA

SE

M

EN

T -A

R

EA

P H

AS

E

FI

R

E P

R O

TE

C

TI

O

N D

EM

O

LI

TI

O N

1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 1

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_C U

I_ C

F_ Pl an s_

Vo l4

-0

L

I

H

G

18 19 20 21 22 23 24 2523E22E

MATCHLINE

A1 FAD101A

MATCHLINE

A1 FAD103A

MA

TC

HL

IN

E

A1

FA

D1

A

TS

C

WF

C

(6)

(3)

CORRIDOR

WHITE SPACE

1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL

NOTES, SYMBOLS, AMD ABBREVIATIONS.

2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,

NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED

CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED

ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE

CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE

THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.

3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT

MANAGER AND THE WRITTEN APPROVAL OF USACE.

4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND

NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE

FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.

THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.

5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING

CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR

GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING

CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE

FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO

FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE

DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE

CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN

WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.

COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND

REMOTE PANELS WITH TECHNICIAN.

NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT

EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT

UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -

WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED

WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.

GENERAL NOTES - DEMOLITION W ORK

1. EXISTING TAMPER SWITCHES AND FLOW SWITCHES TO BE DEMOLISHED.

2. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES WITHIN

THE AREA OF WORK AS NESCESSARY TO ACCOMMODATE NEW LAYOUT.

3. UNOCCUPIED MECHANICAL AREA.

KEYED NOTES - DEMOLITION W ORK

KEY PLAN

N

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 2 3 4 5

D

C

B

A

8'4' 16'

CUI

CUI

C U

I

W R

IG

H

T-

PA

TT

ER

SO

N

A

IR

F O

R C

E

BA

SE

D

AY

TO

N , O

H

IO

R

EP

AI

R

/R

EN

O

VA

TE

A

FM

C

H Q

B U

IL

D

IN

G

(B

2)

P H

AS

E

B262 PHASE

P2 N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

J.

B

EN

SO

N

FAD102A

AR

EA

D

EM

O

LI

TI

O

N C

EI

LI

N G

P

LA

N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

JA

C

O

BS

E N

G

IN

EE

R

IN

G

G R

O U

P

IN

C

H

IG

H

LA

N D

S

PL

AZ

A

D R

IV

E

SU

IT

E

ST

. L O

U

IS

, M O

J.

A.

B

EA

LS

S.

S.

R O

D R

IG

U

EZ

C .W

. K R

IE

BE

L

D

EC

EM

BE

R

B10262 PHASE 1 - CERTIFIED FINAL

BA

SE

M

EN

T -A

R

EA

P H

AS

E

FI

R

E P

R O

TE

C

TI

O

N D

EM

O

LI

TI

O N

1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_C U

I_ C

F_ Pl an s_

Vo l4

-0

T

S

R

Q

P

O

N

18 19 20 21 22 23 24 2523E22E

MATCHLINE

A1 FAD102A

MA

TC

HL

IN

E

A1

FA

D1

A

WF

C

TS

C

(2

1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL

NOTES, SYMBOLS, AMD ABBREVIATIONS.

2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,

NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED

CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED

ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE

CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE

THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.

3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT

MANAGER AND THE WRITTEN APPROVAL OF USACE.

4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND

NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE

FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.

THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.

5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING

CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR

GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING

CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE

FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO

FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE

DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE

CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN

WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.

COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND

REMOTE PANELS WITH TECHNICIAN.

NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT

EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT

UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -

WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED

WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.

GENERAL NOTES - DEMOLITION W ORK

1. EXISTING MONITOR MODULES, TAMPER SWITCH, AND FLOW SWITCH TO BE

DEMOLISHED.

2. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES WITHIN

THE AREA OF WORK AS NESCESSARY TO ACCOMMODATE NEW LAYOUT.

3. UNOCCUPIED MECHANICAL AREA.

KEYED NOTES - DEMOLITION W ORK

KEY PLAN

N

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 2 3 4 5

D

C

B

A

8'4' 16'

CUI

CUI

C U

I

W R

IG

H

T-

PA

TT

ER

SO

N

A

IR

F O

R C

E

BA

SE

D

AY

TO

N , O

H

IO

R

EP

AI

R

/R

EN

O

VA

TE

A

FM

C

H Q

B U

IL

D

IN

G

(B

2)

P H

AS

E

B262 PHASE

P2 N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

J.

B

EN

SO

N

FAD103A

AR

EA

D

EM

O

LI

TI

O

N C

EI

LI

N G

P

LA

N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

JA

C

O

BS

E N

G

IN

EE

R

IN

G

G R

O U

P

IN

C

H

IG

H

LA

N D

S

PL

AZ

A

D R

IV

E

SU

IT

E

ST

. L O

U

IS

, M O

J.

A.

B

EA

LS

S.

S.

R O

D R

IG

U

EZ

C .W

. K R

IE

BE

L

D

EC

EM

BE

R

B10262 PHASE 1 - CERTIFIED FINAL

BA

SE

M

EN

T -A

R

EA

P H

AS

E

FI

R

E P

R O

TE

C

TI

O

N D

EM

O

LI

TI

O N

1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 3

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_C U

I_ C

F_ Pl an s_

Vo l4

-0

G

F

E

D

C

A

11 12 13 14 15 16 18 1917

MA

TC

HL

IN

E

A1

FA

D1

A

MA

TC

HL

IN

E

A1

FA

D1

A

MATCHLINE

A1 FAD105A

WF

C

TS

C

(2

STAIR 8

EXIT PASSAGE

PLUMBING EQUIPMENT

MAIN ELECTRICAL

ELECTRICAL

UTILITY

UTILITY

1. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES WITHIN

THE AREA OF WORK AS NESCESSARY TO ACCOMMODATE NEW LAYOUT.

B

1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL

NOTES, SYMBOLS, AMD ABBREVIATIONS.

2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,

NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED

CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED

ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE

CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE

THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.

3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT

MANAGER AND THE WRITTEN APPROVAL OF USACE.

4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND

NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE

FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.

THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.

5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING

CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR

GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING

CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE

FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO

FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE

DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE

CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN

WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.

COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND

REMOTE PANELS WITH TECHNICIAN.

NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT

EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT

UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -

WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED

WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.

GENERAL NOTES - DEMOLITION W ORK

KEYED NOTES - DEMOLITION W ORK

KEY PLAN

N

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 2 3 4 5

D

C

B

A

8'4' 16'

CUI

CUI

C U

I

W R

IG

H

T-

PA

TT

ER

SO

N

A

IR

F O

R C

E

BA

SE

D

AY

TO

N , O

H

IO

R

EP

AI

R

/R

EN

O

VA

TE

A

FM

C

H Q

B U

IL

D

IN

G

(B

2)

P H

AS

E

B262 PHASE

P2 N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

J.

B

EN

SO

N

FAD104A

AR

EA

D

EM

O

LI

TI

O

N C

EI

LI

N G

P

LA

N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

JA

C

O

BS

E N

G

IN

EE

R

IN

G

G R

O U

P

IN

C

H

IG

H

LA

N D

S

PL

AZ

A

D R

IV

E

SU

IT

E

ST

. L O

U

IS

, M O

J.

A.

B

EA

LS

S.

S.

R O

D R

IG

U

EZ

C .W

. K R

IE

BE

L

D

EC

EM

BE

R

B10262 PHASE 1 - CERTIFIED FINAL

BA

SE

M

EN

T -A

R

EA

P H

AS

E

FI

R

E P

R O

TE

C

TI

O

N D

EM

O

LI

TI

O N

1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 4

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_C U

I_ C

F_ Pl an s_

Vo l4

-0

K

J

I

H

G

11 12 13 14 15 16 18 1917

MA

TC

HL

IN

E

A1

FA

D1

A

MATCHLINE

A1 FAD104A

MA

TC

HL

IN

E

A1

FA

D1

A

MATCHLINE

A1 FAD106A

1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL

NOTES, SYMBOLS, AMD ABBREVIATIONS.

2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,

NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED

CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED

ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE

CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE

THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.

3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT

MANAGER AND THE WRITTEN APPROVAL OF USACE.

4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND

NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE

FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.

THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.

5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING

CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR

GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING

CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE

FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO

FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE

DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE

CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN

WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.

COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND

REMOTE PANELS WITH TECHNICIAN.

NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT

EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT

UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -

WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED

WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.

GENERAL NOTES - DEMOLITION W ORK

1. NO ANTICIPATED WORK IN THIS AREA.

KEYED NOTES - DEMOLITION W ORK

KEY PLAN

N

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 2 3 4 5

D

C

B

A

8'4' 16'

CUI

CUI

C U

I

W R

IG

H

T-

PA

TT

ER

SO

N

A

IR

F O

R C

E

BA

SE

D

AY

TO

N , O

H

IO

R

EP

AI

R

/R

EN

O

VA

TE

A

FM

C

H Q

B U

IL

D

IN

G

(B

2)

P H

AS

E

B262 PHASE

P2 N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

J.

B

EN

SO

N

FAD105A

AR

EA

D

EM

O

LI

TI

O

N C

EI

LI

N G

P

LA

N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

JA

C

O

BS

E N

G

IN

EE

R

IN

G

G R

O U

P

IN

C

H

IG

H

LA

N D

S

PL

AZ

A

D R

IV

E

SU

IT

E

ST

. L O

U

IS

, M O

J.

A.

B

EA

LS

S.

S.

R O

D R

IG

U

EZ

C .W

. K R

IE

BE

L

D

EC

EM

BE

R

B10262 PHASE 1 - CERTIFIED FINAL

BA

SE

M

EN

T -A

R

EA

P H

AS

E

FI

R

E P

R O

TE

C

TI

O

N D

EM

O

LI

TI

O N

1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 5

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_C U

I_ C

F_ Pl an s_

Vo l4

-0

F

M

T

S

R

Q

P

O

N

11 12 13 14 15 16 18 1917

MATCHLINE

A1 FAD105A

MA

TC

HL

IN

E

A1

FA

D1

A

MA

TC

HL

IN

E

A1

FA

D1

A

TS

C

WF

C

(2

1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL

NOTES, SYMBOLS, AMD ABBREVIATIONS.

2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,

NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED

CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED

ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE

CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE

THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.

3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT

MANAGER AND THE WRITTEN APPROVAL OF USACE.

4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND

NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE

FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.

THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.

5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING

CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR

GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING

CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE

FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO

FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE

DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE

CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN

WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.

COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND

REMOTE PANELS WITH TECHNICIAN.

NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT

EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT

UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -

WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED

WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.

GENERAL NOTES - DEMOLITION W ORK

KEYED NOTES - DEMOLITION W ORK

1. NO ANTICIPATED WORK IN THIS AREA.

2. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES WITHIN

THE AREA OF WORK AS NESCESSARY TO ACCOMMODATE NEW LAYOUT.

KEY PLAN

N

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 2 3 4 5

D

C

B

A

8'4' 16'

CUI

CUI

C U

I

W R

IG

H

T-

PA

TT

ER

SO

N

A

IR

F O

R C

E

BA

SE

D

AY

TO

N , O

H

IO

R

EP

AI

R

/R

EN

O

VA

TE

A

FM

C

H Q

B U

IL

D

IN

G

(B

2)

P H

AS

E

B262 PHASE

P2 N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

J.

B

EN

SO

N

FAD106A

AR

EA

D

EM

O

LI

TI

O

N C

EI

LI

N G

P

LA

N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

JA

C

O

BS

E N

G

IN

EE

R

IN

G

G R

O U

P

IN

C

H

IG

H

LA

N D

S

PL

AZ

A

D R

IV

E

SU

IT

E

ST

. L O

U

IS

, M O

J.

A.

B

EA

LS

S.

S.

R O

D R

IG

U

EZ

C .W

. K R

IE

BE

L

D

EC

EM

BE

R

B10262 PHASE 1 - CERTIFIED FINAL

BA

SE

M

EN

T -A

R

EA

P H

AS

E

FI

R

E P

R O

TE

C

TI

O

N D

EM

O

LI

TI

O N

1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 6

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_C U

I_ C

F_ Pl an s_

Vo l4

-0

G

4 5 6 7 8 9 10 11 12

MA

TC

HL

IN

E

A1

FA

D1

A

MA

TC

HL

IN

E

A1

FA

D1

A

MATCHLINE

A1 FAD108A

TS

C

WF

C

(2

B

1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL

NOTES, SYMBOLS, AMD ABBREVIATIONS.

2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,

NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED

CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED

ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE

CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE

THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.

3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT

MANAGER AND THE WRITTEN APPROVAL OF USACE.

4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND

NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE

FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.

THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.

5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING

CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR

GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING

CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE

FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO

FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE

DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE

CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN

WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.

COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND

REMOTE PANELS WITH TECHNICIAN.

NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT

EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT

UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -

WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED

WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.

GENERAL NOTES - DEMOLITION W ORK

KEYED NOTES - DEMOLITION W ORK

1. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES WITHIN

THE AREA OF WORK AS NESCESSARY TO ACCOMMODATE NEW LAYOUT.

2. UNOCCUPIED MECHANICAL AREA.

KEY PLAN

N

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 2 3 4 5

D

C

B

A

8'4' 16'

CUI

CUI

C U

I

W R

IG

H

T-

PA

TT

ER

SO

N

A

IR

F O

R C

E

BA

SE

D

AY

TO

N , O

H

IO

R

EP

AI

R

/R

EN

O

VA

TE

A

FM

C

H Q

B U

IL

D

IN

G

(B

2)

P H

AS

E

B262 PHASE

P2 N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

J.

B

EN

SO

N

FAD107A

AR

EA

D

EM

O

LI

TI

O

N C

EI

LI

N G

P

LA

N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

JA

C

O

BS

E N

G

IN

EE

R

IN

G

G R

O U

P

IN

C

H

IG

H

LA

N D

S

PL

AZ

A

D R

IV

E

SU

IT

E

ST

. L O

U

IS

, M O

J.

A.

B

EA

LS

S.

S.

R O

D R

IG

U

EZ

C .W

. K R

IE

BE

L

D

EC

EM

BE

R

B10262 PHASE 1 - CERTIFIED FINAL

BA

SE

M

EN

T -A

R

EA

P H

AS

E

FI

R

E P

R O

TE

C

TI

O

N D

EM

O

LI

TI

O N

1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 7

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_C U

I_ C

F_ Pl an s_

Vo l4

-0

K

J

I

H

G

4 5 6 7 8 9 10 11 12

MATCHLINE

A1 FAD107A

MA

TC

HL

IN

E

A1

FA

D1

A

MA

TC

HL

IN

E

A1

FA

D1

A

MATCHLINE

A1 FAD109A

1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL

NOTES, SYMBOLS, AMD ABBREVIATIONS.

2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,

NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED

CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED

ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE

CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE

THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.

3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT

MANAGER AND THE WRITTEN APPROVAL OF USACE.

4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND

NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE

FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.

THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.

5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING

CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR

GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING

CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE

FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO

FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE

DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE

CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN

WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.

COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND

REMOTE PANELS WITH TECHNICIAN.

NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT

EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT

UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -

WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED

WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.

GENERAL NOTES - DEMOLITION W ORK

1. NO ANTICIPATED WORK IN THIS AREA.

KEYED NOTES - DEMOLITION W ORK

KEY PLAN

N

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

1 2 3 4 5

D

C

B

A

8'4' 16'

CUI

CUI

C U

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .