W912QR22R0028_Plans_PH1_Vol6-0000.pdf

PDF 30 MB Posted

Attached to
Renovation of WPAFB Air Force Materiel Command Headquarters; Phase 1
Solicitation number
W912QR22R0028
Issued by

About this file

This solicitation notice provides details for a renovation project at Wright-Patterson Air Force Base in Ohio. The U.S. Army Corps of Engineers Louisville District plans to issue a request for proposal for design and construction services for Phase 1 of the renovation of the Air Force Materiel Command Headquarters Building. Phase 1 involves repairing and modernizing over 60,000 square feet of space, including replacement of HVAC, electrical, plumbing and telecommunications systems. Exterior work includes window, door and wall insulation replacement as well as waterproofing. The contract duration is estimated at 1,095 calendar days with anticipated work commencing in November 2022. The solicitation will utilize best value evaluation of technical and price factors on a fixed price contract. The projected value ranges from $100-250 million. Offerors must register in the System for Award Management to receive solicitation amendments when issued.

View the file

Other files

File Type Posted
W912QR22R0028_CUI_CF_Plans-0004.pdf PDF
W912QR22R0028_CUI_CF_Specs-0004.pdf PDF
W912QR22R0028_CUI_CF_Plans-0003.pdf PDF
W912QR22R0028_CUI_CF_Specs-0003.pdf PDF
W912QR22R0028_CUI_CF_CIDV2_FFE-0003.pdf PDF
W912QR22R0028_CUI_CF_Specs_Vol2-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol7-0002.pdf PDF
W912QR22R0028_CUI_CF_Specs_Vol4-0002.pdf PDF
W912QR22R0028_CUI_Pre bid contractors site visit requested photos - 1 Dec 2022.pdf PDF
W912QR22R0028_CUI_CF_Specs_Vol3-0002.pdf PDF
W912QR22R0028_CUI_CF_CIDV2_FFE-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol5-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol4-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol3-0002.pdf PDF
W912QR22R0028_CUI_CF_CIDV1_SID-0002.pdf PDF
W912QR22R0028_CUI_CF_Specs_Vol5-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol1-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol6-0002.pdf PDF
W912QR22R0028_CUI_Site Visit Attendee list - AFMC HQ Project 1 DEC 22.pdf PDF
W912QR22R0028_CUI_CF_Specs_Vol1-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol2-0002.pdf PDF
W912QR22R0028_CUI_CF_Plans_Vol8-0002.pdf PDF
W912QR22R0028_AFMC_Phase 1_CID_V2_FFE-0001.pdf PDF
JA - AFMC HQ - Reno Trane Chillers - SAM Redacted.pdf PDF
W912QR22R0028_Plans_PH1_Vol8-0000.pdf PDF
W912QR22R0028_Plans_PH1_Vol2-0000.pdf PDF
JA - AFMC HQ Reno - FFE Basis of Design - SAM Redacted.pdf PDF
W912QR22R0028_Specs_PH1_Vol1-0000.pdf PDF
REDACTED - SPE - Signed Class JA for Basis of Design Items.pdf PDF
JA - AFMC HQ Reno - Fire Alarm System - Brand Name - SAM Redacted.pdf PDF
W912QR22R0028_Specs_PH1_Vol2-0000.pdf PDF
W912QR22R0028_Plans_PH1_Vol7-0000.pdf PDF
JA - AFMC HQ Reno - Integrated Sec Platform - Brand Name - SAM Redacted.pdf PDF
W912QR22R0028_Plans_PH1_Vol1-0000.pdf PDF
W912QR22R0028_Specs_PH1_Vol5-0000.pdf PDF
W912QR22R0028_Specs_PH1_Vol4-0000.pdf PDF
W912QR22R0028_Plans_PH1_Vol4-0000.pdf PDF
W912QR22R0028_Plans_PH1_Vol5-0000.pdf PDF
JA - AFMC HQ Reno - Brand Name Siemens Talon or Johnson Controls - SAM Redacted.pdf PDF
W912QR22R0028_Plans_PH1_Vol3-0000.pdf PDF
W912QR22R0028_Specs_PH1_Vol3-0000.pdf PDF
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Controlled by: USACE-LRL-ED-MA CUI Category(ies):

LDC or Distribution Statement: N/A POC: Blake Gevedon Contracting Specialist william.b.gevedon@usace.army.mi 502.315.6791

Materials shall be submitted to potential offerors currently certified in the Joint Certification Program (JCP) only.

T ROAD

A S

T R

E E

T

O G

D E

N A

V E

N U

E

C H

ID

L

A W

R O

A D

B R

O A D

N R

O A

D

A STREET

S

TA

TE

R

O U

TE

WRIGHT-PATTERSON AIR

FORCE BASE

STATE R

O

UTE 4

IN

T

E R

S T

A T

E

INTERSTATE 70

S T

A T

E R

O U

T E

STATE ROUTE 4

STATE ROUTE 444

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5

D

C

B

A

US Army Corps of Engineers ®

P2 NO.:

ISSUE DATE:

VOLUME:

CUI

CUI

C U

I

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E D

A Y

T O

N

O H

IO

R E

P A

IR

/R

E N

O V

A T

E A

F M

C H

Q B

U

IL

D

IN

G

B

P

H A

S E

SOLICITATION NO.:

PHASEREPAIR/RENOVATE AFMC HEADQUARTERS BUILDING

B 10262

W912QR21R0028

CONTROLLED BY: USACE

CONTROLLED BY: LOUISVILLE DISTRICT

CUI CATEGORY: CUI BASIC

DISTRIBUTION/DISSEMINATION CONTROLS: DISTRO C

POC: STEVE SKAGGS, 502-315-6368

B262 PHASE

P

N O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J

B E

N S

O N

PLAN NORTH PLAN NORTHTRUE NORTH TRUE NORTH

G006

V O

L U

M E

P H

A S

E

C O

V E

R S

H E

E T

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

N

B

R O

A D

W A

Y S

T

L O

U

IS

M

O

R

M E

S S

E L

N

R E

N D

L E

M A

N

J

C O

R S

O N

O C

T O

B E

R

W

Q R

R

X X

X X

B10262 PHASE 1 - 90% FINAL REVISED - NOT FOR CONSTRUCTION

LOUISVILLE DISTRICT

475429

20 OCTOBER 2022

M E

C H

A N

IC

A

L

WRIGHT-PATTERSON AIR FORCE BASE

DAYTON, OHIO 45433

B10262 PHASE 1 - 90% FINAL REVISED - NOT FOR CONSTRUCTION

G E

N E

R A

L

MECHANICAL

LOCATION MAPVICINITY MAP

W

2Q R

R

_P la ns _P

H 1_

Vo l6

-0

ARIMS: 200A Disposition: Maintain for 15yrs after construction

10 November 2022

W912QR22R0028

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5

D

C

B

A

CUI

CUI

C U

I

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E D

A Y

T O

N

O H

IO

R E

P A

IR

/R

E N

O V

A T

E A

F M

C H

Q B

U

IL

D

IN

G

B

P

H A

S E

B262 PHASE

P

N O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J

B E

N S

O N

G014

V O

L U

M E

P H

A S

E

S H

E E

T I

N D

E X

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

N

B

R O

A D

W A

Y S

T

L O

U

IS

M

O

R

M E

S S

E L

N

R E

N D

L E

M A

N

J

C O

R S

O N

O C

T O

B E

R

W

Q R

R

X X

X X

B10262 PHASE 1 - 90% FINAL REVISED - NOT FOR CONSTRUCTION

M E

C H

A N

IC

A

L

G E

N E

R A

L

GENERAL SHEET INDEX MECHANICAL SHEET INDEX

G006 VOLUME 6 - PHASE 1 COVER SHEET - MECHANICAL

G014 VOLUME 6 - PHASE 1 SHEET INDEX - MECHANICAL

MP110B AREA PIPING PLAN - FIRST FLOOR - AREA 10 - PHASE 1

MP111B AREA PIPING PLAN - FIRST FLOOR - AREA 11 - PHASE 1

MP112B AREA PIPING PLAN - FIRST FLOOR - AREA 12 - PHASE 1

MP100C OVERALL PIPING PLAN - SECOND FLOOR - PHASE 1

MP101C AREA PIPING PLAN - SECOND FLOOR - AREA 1 - PHASE 1

MP102C AREA PIPING PLAN - SECOND FLOOR - AREA 2 - PHASE 1

MP103C AREA PIPING PLAN - SECOND FLOOR - AREA 3 - PHASE 1

MP104C AREA PIPING PLAN - SECOND FLOOR - AREA 4 - PHASE 1

MP105C AREA PIPING PLAN - SECOND FLOOR - AREA 5 - PHASE 1

MP106C AREA PIPING PLAN - SECOND FLOOR - AREA 6 - PHASE 1

MP107C AREA PIPING PLAN - SECOND FLOOR - AREA 7 - PHASE 1

MP108C AREA PIPING PLAN - SECOND FLOOR - AREA 8 - PHASE 1

MP109C AREA PIPING PLAN - SECOND FLOOR - AREA 9 - PHASE 1

MP110C AREA PIPING PLAN - SECOND FLOOR - AREA 10 - PHASE 1

MP111C AREA PIPING PLAN - SECOND FLOOR - AREA 11 - PHASE 1

MP112C AREA PIPING PLAN - SECOND FLOOR - AREA 12 - PHASE 1

MR100R OVERALL MECHANICAL PLAN - ROOF - PHASE 1

MR101R AREA MECHANICAL PLAN - ROOF - AREA 1 - PHASE 1

MR102R AREA MECHANICAL PLAN - ROOF - AREA 2 - PHASE 1

MR103R AREA MECHANICAL PLAN - ROOF - AREA 3 - PHASE 1

MR104R AREA MECHANICAL PLAN - ROOF - AREA 4 - PHASE 1

MR105R AREA MECHANICAL PLAN - ROOF - AREA 5 - PHASE 1

MR106R AREA MECHANICAL PLAN - ROOF - AREA 6 - PHASE 1

MR107R AREA MECHANICAL PLAN - ROOF - AREA 7 - PHASE 1

MR108R AREA MECHANICAL PLAN - ROOF - AREA 8 - PHASE 1

MR109R AREA MECHANICAL PLAN - ROOF - AREA 9 - PHASE 1

MR110R AREA MECHANICAL PLAN - ROOF - AREA 10 - PHASE 1

MR111R AREA MECHANICAL PLAN - ROOF - AREA 11 - PHASE 1

MR112R AREA MECHANICAL PLAN - ROOF - AREA 12 - PHASE 1

M301 HVAC SECTIONS - PHASE 1

M302 HVAC SECTIONS - PHASE 1

M303 HVAC SECTIONS - PHASE 1

M401 ENLARGED HVAC PLANS - PHASE 1

M402 ENLARGED HVAC PLANS - PHASE 1

M403 ENLARGED HVAC PLANS - PHASE 1

M404 ENLARGED HVAC PLANS - PHASE 1

M405 ENLARGED HVAC PLANS - PHASE 1

M406 ENLARGED HVAC PLANS - PHASE 1

M501 HVAC DETAILS - PHASE 1

M502 HVAC DETAILS - PHASE 1

M503 HVAC DETAILS - PHASE 1

M504 HVAC DETAILS - PHASE 1

M505 HVAC DETAILS - PHASE 1

M506 HVAC DETAILS - PHASE 1

M507 HVAC DETAILS - PHASE 1

M508 HVAC DETAILS - PHASE 1

M509 HVAC DETAILS - PHASE 1

M510 HVAC DETAILS - PHASE 1

M601 HVAC SCHEDULES - PHASE 1

M602 HVAC SCHEDULES - PHASE 1

M603 HVAC SCHEDULES - PHASE 1

M604 HVAC SCHEDULES - PHASE 1

M701 ONE-LINE DIAGRAMS - PHASE 1

M702 ONE-LINE DIAGRAMS - PHASE 1

M703 ONE-LINE DIAGRAMS - PHASE 1

M704 ONE-LINE DIAGRAMS - PHASE 1

M705 ONE-LINE DIAGRAMS - PHASE 1

M706 ONE-LINE DIAGRAMS - PHASE 1

M707 ONE-LINE DIAGRAMS - PHASE 1

M801 CONTROLS SYMBOLS LEGEND - PHASE 1

M802 HVAC CONTROLS - PHASE 1

M803 HVAC CONTROLS - PHASE 1

M804 HVAC CONTROLS - PHASE 1

M805 HVAC CONTROLS - PHASE 1

M806 HVAC CONTROLS - PHASE 1

M807 HVAC CONTROLS - PHASE 1

M808 HVAC CONTROLS - PHASE 1

M809 HVAC CONTROLS - PHASE 1

M810 HVAC CONTROLS - PHASE 1

M811 HVAC CONTROLS - PHASE 1

M812 LADDER DIAGRAMS - PHASE 1

M813 LADDER DIAGRAMS - PHASE 1

M814 CONTROLS SCHEDULES - PHASE 1

M815 I/O POINTS LISTS - PHASE 1

M816 I/O POINTS LISTS - PHASE 1

M817 I/O POINTS LISTS - PHASE 1

M818 I/O POINTS LISTS - PHASE 1

M819 I/O POINTS LISTS - PHASE 1

M820 I/O POINTS LISTS - PHASE 1

M821 I/O POINTS LISTS - PHASE 1

M822 I/O POINTS LISTS - PHASE 1

M823 I/O POINTS LISTS - PHASE 1

M824 I/O POINTS LISTS - PHASE 1

M001 GENERAL NOTES, ABBREVIATIONS - PHASE 1

M002 GENERAL NOTES, ABBREVIATIONS CONT. - PHASE 1

MS-101 SITE UTILITY PLAN - PHASE 1

MD100A OVERALL DEMOLITION PLAN - BASEMENT - PHASE 1

MD101A AREA DEMOLITION PLAN - BASEMENT - AREA 1 - PHASE 1

MD102A AREA DEMOLITION PLAN - BASEMENT - AREA 2 - PHASE 1

MD103A AREA DEMOLITION PLAN - BASEMENT - AREA 3 - PHASE 1

MD104A AREA DEMOLITION PLAN - BASEMENT - AREA 4 - PHASE 1

MD105A AREA DEMOLITION PLAN - BASEMENT - AREA 5 - PHASE 1

MD106A AREA DEMOLITION PLAN - BASEMENT - AREA 6 - PHASE 1

MD107A AREA DEMOLITION PLAN - BASEMENT - AREA 7 - PHASE 1

MD108A AREA DEMOLITION PLAN - BASEMENT - AREA 8 - PHASE 1

MD109A AREA DEMOLITION PLAN - BASEMENT - AREA 9 - PHASE 1

MD110A AREA DEMOLITION PLAN - BASEMENT - AREA 10 - PHASE 1

MD111A AREA DEMOLITION PLAN - BASEMENT - AREA 11 - PHASE 1

MD112A AREA DEMOLITION PLAN - BASEMENT - AREA 12 - PHASE 1

MD100B OVERALL DEMOLITION PLAN - FIRST FLOOR - PHASE 1

MD101B AREA DEMOLITION PLAN - FIRST FLOOR - AREA 1 - PHASE 1

MD102B AREA DEMOLITION PLAN - FIRST FLOOR - AREA 2 - PHASE 1

MD103B AREA DEMOLITION PLAN - FIRST FLOOR - AREA 3 - PHASE 1

MD104B AREA DEMOLITION PLAN - FIRST FLOOR - AREA 4 - PHASE 1

MD105B AREA DEMOLITION PLAN - FIRST FLOOR - AREA 5 - PHASE 1

MD106B AREA DEMOLITION PLAN - FIRST FLOOR - AREA 6 - PHASE 1

MD107B AREA DEMOLITION PLAN - FIRST FLOOR - AREA 7 - PHASE 1

MD108B AREA DEMOLITION PLAN - FIRST FLOOR - AREA 8 - PHASE 1

MD109B AREA DEMOLITION PLAN - FIRST FLOOR - AREA 9 - PHASE 1

MD110B AREA DEMOLITION PLAN - FIRST FLOOR - AREA 10 - PHASE 1

MD111B AREA DEMOLITION PLAN - FIRST FLOOR - AREA 11 - PHASE 1

MD112B AREA DEMOLITION PLAN - FIRST FLOOR - AREA 12 - PHASE 1

MD119B AREA DEMOLITION PLAN - FIRST FLOOR - AREA 19 - PHASE 1

MD100C OVERALL DEMOLITION PLAN - SECOND FLOOR - PHASE 1

MD101C AREA DEMOLITION PLAN - SECOND FLOOR - AREA 1 - PHASE 1

MD102C AREA DEMOLITION PLAN - SECOND FLOOR - AREA 2 - PHASE 1

MD103C AREA DEMOLITION PLAN - SECOND FLOOR - AREA 3 - PHASE 1

MD104C AREA DEMOLITION PLAN - SECOND FLOOR - AREA 4 - PHASE 1

MD105C AREA DEMOLITION PLAN - SECOND FLOOR - AREA 5 - PHASE 1

MD106C AREA DEMOLITION PLAN - SECOND FLOOR - AREA 6 - PHASE 1

MD107C AREA DEMOLITION PLAN - SECOND FLOOR - AREA 7 - PHASE 1

MD108C AREA DEMOLITION PLAN - SECOND FLOOR - AREA 8 - PHASE 1

MD109C AREA DEMOLITION PLAN - SECOND FLOOR - AREA 9 - PHASE 1

MD110C AREA DEMOLITION PLAN - SECOND FLOOR - AREA 10 - PHASE 1

MD111C AREA DEMOLITION PLAN - SECOND FLOOR - AREA 11 - PHASE 1

MD112C AREA DEMOLITION PLAN - SECOND FLOOR - AREA 12 - PHASE 1

MD100R OVERALL DEMOLITION PLAN - ROOF - PHASE 1

MD119R AREA DEMOLITION PLAN - ROOF - AREA 19 - PHASE 1

MD401 ENLARGED DEMOLITION PLAN - ROOF - PHASE 1

MH100A OVERALL DUCTWORK PLAN - BASEMENT - PHASE 1

MH101A AREA DUCTWORK PLAN - BASEMENT - AREA 1 - PHASE 1

MH102A AREA DUCTWORK PLAN - BASEMENT - AREA 2 - PHASE 1

MH103A AREA DUCTWORK PLAN - BASEMENT - AREA 3 - PHASE 1

MH104A AREA DUCTWORK PLAN - BASEMENT - AREA 4 - PHASE 1

MH105A AREA DUCTWORK PLAN - BASEMENT - AREA 5 - PHASE 1

MH106A AREA DUCTWORK PLAN - BASEMENT - AREA 6 - PHASE 1

MH107A AREA DUCTWORK PLAN - BASEMENT - AREA 7 - PHASE 1

MH108A AREA DUCTWORK PLAN - BASEMENT - AREA 8 - PHASE 1

MH109A AREA DUCTWORK PLAN - BASEMENT - AREA 9 - PHASE 1

MH110A AREA DUCTWORK PLAN - BASEMENT - AREA 10 - PHASE 1

MH110A-A AREA DUCTWORK PLAN - NORTH VESTIBULE CLIN - PHASE 1

MH111A AREA DUCTWORK PLAN - BASEMENT - AREA 11 - PHASE 1

MH112A AREA DUCTWORK PLAN - BASEMENT - AREA 12 - PHASE 1

MH100B OVERALL DUCTWORK PLAN - FIRST FLOOR - PHASE 1

MH101B AREA DUCTWORK PLAN - FIRST FLOOR - AREA 1 - PHASE 1

MH102B AREA DUCTWORK PLAN - FIRST FLOOR - AREA 2 - PHASE 1

MH103B AREA DUCTWORK PLAN - FIRST FLOOR - AREA 3 - PHASE 1

MH104B AREA DUCTWORK PLAN - FIRST FLOOR - AREA 4 - PHASE 1

MH105B AREA DUCTWORK PLAN - FIRST FLOOR - AREA 5 - PHASE 1

MH106B AREA DUCTWORK PLAN - FIRST FLOOR - AREA 6 - PHASE 1

MH107B AREA DUCTWORK PLAN - FIRST FLOOR - AREA 7 - PHASE 1

MH108B AREA DUCTWORK PLAN - FIRST FLOOR - AREA 8 - PHASE 1

MH109B AREA DUCTWORK PLAN - FIRST FLOOR - AREA 9 - PHASE 1

MH110B AREA DUCTWORK PLAN - FIRST FLOOR - AREA 10 - PHASE 1

MH110B-A AREA DUCTWORK PLAN - NORTH VESTIBULE CLIN - PHASE 1

MH111B AREA DUCTWORK PLAN - FIRST FLOOR - AREA 11 - PHASE 1

MH112B AREA DUCTWORK PLAN - FIRST FLOOR - AREA 12 - PHASE 1

MH100C OVERALL DUCTWORK PLAN - SECOND FLOOR - PHASE 1

MH101C AREA DUCTWORK PLAN - SECOND FLOOR - AREA 1 - PHASE 1

MH102C AREA DUCTWORK PLAN - SECOND FLOOR - AREA 2 - PHASE 1

MH103C AREA DUCTWORK PLAN - SECOND FLOOR - AREA 3 - PHASE 1

MH104C AREA DUCTWORK PLAN - SECOND FLOOR - AREA 4 - PHASE 1

MH105C AREA DUCTWORK PLAN - SECOND FLOOR - AREA 5 - PHASE 1

MH106C AREA DUCTWORK PLAN - SECOND FLOOR - AREA 6 - PHASE 1

MH107C AREA DUCTWORK PLAN - SECOND FLOOR - AREA 7 - PHASE 1

MH108C AREA DUCTWORK PLAN - SECOND FLOOR - AREA 8 - PHASE 1

MH109C AREA DUCTWORK PLAN - SECOND FLOOR - AREA 9 - PHASE 1

MH110C AREA DUCTWORK PLAN - SECOND FLOOR - AREA 10 - PHASE 1

MH111C AREA DUCTWORK PLAN - SECOND FLOOR - AREA 11 - PHASE 1

MH112C AREA DUCTWORK PLAN - SECOND FLOOR - AREA 12 - PHASE 1

MP100A OVERALL PIPING PLAN - BASEMENT - PHASE 1

MP101A AREA PIPING PLAN - BASEMENT - AREA 1 - PHASE 1

MP102A AREA PIPING PLAN - BASEMENT - AREA 2 - PHASE 1

MP103A AREA PIPING PLAN - BASEMENT - AREA 3 - PHASE 1

MP104A AREA PIPING PLAN - BASEMENT - AREA 4 - PHASE 1

MP105A AREA PIPING PLAN - BASEMENT - AREA 5 - PHASE 1

MP106A AREA PIPING PLAN - BASEMENT - AREA 6 - PHASE 1

MP107A AREA PIPING PLAN - BASEMENT - AREA 7 - PHASE 1

MP108A AREA PIPING PLAN - BASEMENT - AREA 8 - PHASE 1

MP109A AREA PIPING PLAN - BASEMENT - PHASE 1

MP110A AREA PIPING PLAN - BASEMENT - AREA 10 - PHASE 1

MP111A AREA PIPING PLAN - BASEMENT - AREA 11 - PHASE 1

MP112A AREA PIPING PLAN - BASEMENT - AREA 12 - PHASE 1

MP100B OVERALL PIPING PLAN - FIRST FLOOR - PHASE 1

MP101B AREA PIPING PLAN - FIRST FLOOR - AREA 1 - PHASE 1

MP102B AREA PIPING PLAN - FIRST FLOOR - AREA 2 - PHASE 1

MP103B AREA PIPING PLAN - FIRST FLOOR - AREA 3 - PHASE 1

MP104B AREA PIPING PLAN - FIRST FLOOR - AREA 4 - PHASE 1

MP105B AREA PIPING PLAN - FIRST FLOOR - PHASE 1

MP106B AREA PIPING PLAN - FIRST FLOOR - AREA 6 - PHASE 1

MP107B AREA PIPING PLAN - FIRST FLOOR - AREA 7 - PHASE 1

MP108B AREA PIPING PLAN - FIRST FLOOR - AREA 8 - PHASE 1

MP109B AREA PIPING PLAN - FIRST FLOOR - AREA 9 - PHASE 1

W

2Q R

R

_P la ns _P

H 1_

Vo l6

-0

ARIMS: 200A Disposition: Maintain for 15yrs after construction

DUCTW ORK SYMBOLS PIPING SYMBOLS

MECHANICAL SYMBOL LEGEND

VALVE SYMBOLS (CON'T) CONTROLS SYMBOLS

(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)

PIPING TYPE

GENERAL NOTES

DRAW ING/DETAIL REFERENCE KEY

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

P.

Q.

R.

S.

T.

U.

V.

W.

X.

Y.

Z.

AA.

AB.

S

T

GATE VALVE W/ 3/4" HOSE THREAD ADAPTER

SAFETY VALVE OR PRESSURE RELIEF VALVE

TEMPERATURE WELL

TW O-WAY CONTROL VALVE

THREE-WAY CONTROL VALVE

VENTURI FLOW METER

PRESSURE REDUCING VALVE (PRV)

CEILING RETURN AIR GRILLE OR RETURN AIR REGISTER

SIDEWALL SUPPLY OR RETURN AIR REGISTER OR GRILLE

AUTOMATIC AIR VENT

PRESSURE GAGE WITH COCK

MANUAL AIR VENT

STANDARD ECCENTRIC DUCT TRANSITION

STANDARD CONCENTRIC DUCT TRANSITION

STANDARD ROUND BRANCH DUCT (SPIN-IN)

SECTION THROUGH OVAL OR RECTANGULAR SUPPLY DUCT

DUCT ACCESS DOOR

TYPICAL SUPPLY AIR TEE WITH SPLITTER DAMPER

HORIZONTAL FIRE DAMPER AT FLOOR PENETRATION

CONNECT NEW DUCT TO EXISTING

DUCT WITH ACOUSTICAL LINING

MANUAL VOLUME DAMPER

AND OVAL MITERED ELBOWS, UNLESS NOTED OTHERWISE)

VANED RADIUS ELBOW

VANED ELBOW (PROVIDE VANES IN SQUARE, RECTANGULAR,

PIPE ANCHOR

PITCH DOWN IN DIRECTION OF ARROW

DIRECTION OF FLOW

PIPE GUIDE

BRANCH - TOP CONNECTION

ECCENTRIC REDUCER

BRANCH - SIDE CONNECTION

CONCENTRIC REDUCER

RISER UP (ELBOW)

CAPPED PIPE

UNION (SCREWED)

BRANCH - BOTTOM CONNECTION

RISE OR DROP IN PIPE

ORIFICE UNION

FLANGED CONNECTION

STRAINER WITH BLOWDOWN VALVE

TEMPERATURE & PRESSURE PORT

THERMOMETER

MANUAL BALANCING VALVE

SOLENOID VALVE

BALL VALVE

BUTTERFLY VALVE

CT

T

AQ

DUCT AVERAGING TEMPERATURE ELEMENT

RECEIVER PRESSURE GAUGE (PANEL MTD.)

CURRENT SENSING RELAY

LIQUID FLOW METER

AQUASTAT

DIFFERENTIAL PRESSURE SWITCH (DIGITAL)

DIFFERENTIAL PRESSURE SENSOR/TRANSMITTERDT

SP

DP

PT

HT

LT

PRESSURE TRANSMITTER

MOTOR STARTER (LOCAL OR MCC)

STATIC PRESSURE SENSOR/TRANSMITTER

DUCT HUMIDITY SENSOR/TRANSMITTER

LEVEL TRANSMITTER

VIBRATION SWITCH

SECTION THROUGH ROUND DUCT, SUPPLY OR

EXHAUST AS NOTED

SECTION THROUGH RECTANGULAR RETURN DUCT

XX/XX

ACCESS DOOR IN CEILING

A.D.

FLEXIBLE DUCT, SIZE AS SHOWN

RECTANGULAR-TO-ROUND DUCT TRANSITION

NEEDLE VALVE

A.D.

FLOW SWITCH

RISER DOWN (ELBOW)

FLEX CONNECTION

BELLOWS CONNECTION

FLEX PIPE

ANGLE GATE VALVE

ANGLE GLOBE VALVE

DIAPHRAGM VALVE

QUICK ACTION VALVE

OS&Y VALVE

OS&Y VALVE WITH SUPERVISORY SWITCH

FLANGED VALVE (GATE VALVE SHOWN)

FLOAT VALVE

ORIFICE FLOW PLATE

PS

FS

PRESSURE SWITCH

BLIND FLANGE

WELDED CONNECTION

FLANGED CONNECTION

SOLDERED CONNECTION

THREADED OR "PRESS" CONNECTION

BELL & SPIGOT CONNECTION

SOLVENT CONNECTION

CIRCUIT SETTER

ANGLE VALVE

PLUG VALVE

BALL VALVE

3-WAY VALVE

NEEDLE VALVE/INSTRUMENT VALVE

BUTTERFLY VALVE

GLOBE VALVE

VALVE W/ REDUCERS (GATE VALVE SHOWN)

GATE VALVE

OPEN

NORMAL

CLOSED

NORMAL

VALVE IN RISE

VALVE IN CENTER DROP

VALVE IN DROP

F FIRESTAT

CARBON DIOXIDE (C02) SENSOR

PUMP

SECTION THROUGH RECTANGULAR EXHAUST DUCT

CEILING EXHAUST AIR GRILLE OR EXHAUST AIR REGISTER

PATTERN. NO PATTERN SHOW N EQUALS

CEILING SUPPLY AIR DIFFUSER - ARROWS INDICATE

4-WAY

STANDARD RECTANGULAR BRANCH DUCT (45° TAKE-OFF)

STANDARD ROUND BRANCH DUCT (CONICAL)

DN

UP

RELIEF OR EXHAUST AIR DUCT UP

RELIEF OR EXHAUST AIR DUCT DOWN

IN-LINE 90 DEGREE DROP (RISE) IN DUCT

INCLINED DROP IN DUCT

INCLINED RISE IN DUCT

SUPPLY OR OUTSIDE AIR DUCT DOWN

SUPPLY OR OUTSIDE AIR DUCT UP

RETURN AIR DUCT DOWN

RETURN AIR DUCT UP

FD - FIRE DAMPER

SD - SMOKE DAMPER

FSD - COMBINATION FIRE/SMOKE DAMPER

BD - GRAVITY BACKDRAFT DAMPER

CD - CONTROL DAMPER

MANUAL VOLUME DAMPER

CD

ELECTRIC DAMPER ACTUATORDA

CARBON MONOXIDE (C0) SENSORCM

R REFRIGERANT DETECTOR/SENSOR

MANUALLY ACTIVATED SWITCHHS

(DOUBLE SPHERE NEOPRENE TYPE)

T

FR

H

H

TEMPERATURE SENSOR/TRANSMITTER

HUMIDITY SENSOR/TRANSMITTER

DUCT SMOKE DETECTOR

FREEZESTAT

ROOM THERMOSTAT OR SENSOR

ROOM HUMIDISTAT

S

F FLOW SENSOR

(PULL STAT., PUSH STAT., ETC)

R

M ELECTRIC MOTOR

RELAY

FS FLOW SWITCH

REFER TO SPECIFICATIONS FOR MATERIALS AND METHODS FOR CONSTRUCTION.

COORDINATE LOCATION OF PENETRATIONS WITH THE BUILDING STRUCTURE.

COORDINATE SLAB PENETRATIONS AND SLEEVES PRIOR TO EACH CONCRETE POUR.

FURNISH ACCESS DOORS FOR INSTALLATION IN WALLS AND CEILINGS W HERE ACCESS IS REQUIRED TO

CONCEALED MECHANICAL EQUIPMENT, VALVES, CONTROLS, AND OTHER DEVICES.

ARRANGE WITH AUTHORITIES AND UTILITY COMPANIES FOR PERMITS, FEES, AND SERVICE

CONNECTIONS. VERIFY LOCATIONS AND ARRANGEMENTS AND PAY ALL CHARGES, INCLUDING

INSPECTIONS.

COORDINATE WORK WITH ARCHITECTURAL FEATURES AND COORDINATE WORK SUCH THAT

INTERFERENCES BETWEEN PIPING, DUCTWORK, EQUIPMENT, PLUMBING WORK, ELECTRICAL WORK, FIRE

PROTECTION WORK AND BUILDING STRUCTURE WILL BE AVOIDED.

PROVIDE THE ENTIRE SYSTEM AND ITS COMPONENT ITEMS OF EQUIPMENT IN OPERATING CONDITION

WITHOUT OBJECTIONABLE VIBRATION OR NOISE.

PROVIDE WIRING AND ELECTRICAL CONTROLS IN ACCORDANCE WITH NFPA 70 (NEC).

DO NOT SCALE THESE DRAW INGS FOR CONSTRUCTION PURPOSES.

DUCTWORK SIZES ARE FREE AIR STREAM DIMENSIONS.

INSTALL DUCTWORK AND PIPING TO PROVIDE THE MAXIMUM CLEAR HEIGHT UNDERNEATH.

REFER TO STRUCTURAL DRAWINGS FOR FRAMING REQUIRED AROUND PIPES AND DUCTS PENETRATING

ROOFS, WALLS, AND FLOORS.

REFER TO ARCHITECTURAL ELEVATION DRAWINGS, WHERE THE ARCHITECT HAS DRAWN SUCH

ELEVATIONS, FOR THE LOCATION OF WALL MOUNTED DEVICES.

TAPS TO DIFFUSERS MUST BE SAME SIZE AS DIFFUSER NECK OPENING UNLESS OTHERWISE NOTED

PAINT ABOVE CEILING ITEMS, WHICH CAN BE SEEN THROUGH AIR SLOTS OR GRILLES, FLAT BLACK.

PROVIDE TEMPORARY 30% EFFICIENT, 2" THICK FILTERS OVER RETURN AIR OPENINGS OF ANY AHU'S WHICH ARE PLACED IN SERVICE PRIOR TO COMPLETION OF CONSTRUCTION. REMOVE FILTERS FOR TEST

& BALANCE.

DUCT AND PIPE HANGERS IN UNCONDITIONED SPACE OR EXTERIOR TO BUILDING MUST BE GALVANIZED

STEEL.

PROVIDE ACCESS PANELS FOR DAMPER ACTUATORS AND MOTORS LOCATED INSIDE DUCT OR FAN

HOUSING.

PROVIDE BALANCING DAMPER AT RETURN GRILLES AND EXHAUST GRILLES.

ELEVATIONS AS SHOWN ON THE DRAWINGS ARE TO THE BOTTOM OF PRESSURE PIPING.

MAINTAIN VALVES, STRAINERS, UNIONS, TRAPS, FLANGES, AND OTHER APPURTENANCES ACCESS

CLEARANCES AS REQUIRED.

VALVES MUST BE INSTALLED SO THAT THE VALVE REMAINS IN SERVICE WHEN EQUIPMENT OR PIPING ON

THE EQUIPMENT SIDE OF THE VALVE IS REMOVED.

UNIONS AND/OR FLANGES MUST BE PROVIDED AT EACH PIECE OF EQUIPMENT, IN BYPASSES, AND IN LONG PIPING RUNS (100 FT OR MORE) TO PERMIT DISASSEMBLY FOR ALTERATION AND REPAIRS.

PROVIDE FLEXIBLE CONNECTIONS IN PIPING SYSTEMS CONNECTED TO PUMPS, CHILLERS, AND OTHER EQUIPMENT WHICH REQUIRE VIBRATION ISOLATION EXCEPT WATER COILS. FLEXIBLE CONNECTIONS MUST BE PROVIDED AS CLOSE TO THE EQUIPMENT AS POSSIBLE OR AS INDICATED ON THE DRAWINGS.

REFRIGERANT PIPING IS SHOWN FOR DIAGRAMMATIC PURPOSES ONLY. VERIFY EQUIPMENT LAYOUT AND PIPING WITH THE SELECTED EQUIPMENT MANUFACTURER. COORDINATE ROUTING OF THE PIPING AND EQUIPMENT WITH OTHER TRADES. PROVIDE ENGINEERING SHOP DRAW ING TO SHOW PIPING SIZE AND PIPING LAYOUT, INCLUDING OIL TRAPS, DOUBLE RISERS, SPECIALTIES, DIFFERENCE BETWEEN

COMPRESSOR AND EVAPORATOR, AND LENGTH OF PIPING TO ENSURE PROPER OPERATION AND

COMPLIANCE WITH WARRANTIES OF CONNECTED EQUIPMENT.

PERFORM THE WATER SAMPLE ANALYSIS 30 DAYS PRIOR TO DRAINING EXISTING PIPES. SUBMIT THE REPORT TO THE CONTRACTING OFFICER FOR REVIEW AND INSTRUCTION ON APPROVED DISCHARGE

LOCATION.

CONSTRUCTION FOR SECURE AREAS, AND SECURE AREA MATERIAL AND COMPONENTS, MUST COMPLY WITH UFC 4-010-05 AND IC TECH SPECS FOR ICD/ICS 705 AS REQUIRED TO FULLY MEET AND PASS ALL

ACCREDITATION.

BEFORE FINAL SETTING/ROUGH IN CHECK FOR ADEQUATE SPACING FOR DOORS, LATCHES, ETC.

(SEE BELOW FOR OTHER TYPES)

ABBREVIATIONS

BCWP - BUILDING CONDENSER WATER PUMP

BCW - BUILDING CONDENSER WATER

CPVC - CHLORINATED POLYVINYL CHLORIDE

HDPE - HIGH DENSITY POLYETHYLENE

VFD - VARIABLE SPEED DRIVE

VALVE SYMBOLS

CHECK VALVE (NON SLAM)

PLUG VALVE

GLOBE VALVE

GATE VALVE

CONDENSER WATER RETURN

CONDENSER WATER SUPPLY

CWR

HEATING WATER RETURN

HEATING WATER SUPPLY

HWR

HWS

CWS

AHU CONDENSATE DRAINCD

DRAIND

CHILLED WATER RETURN

CHILLED WATER SUPPLY

CHWR

CHWS

POINT OF CONNECTION - NEW TO EXISTING

DRAWING NOTE REFERENCE1

MISCELLANEOUS

SHEET NUMBER ON WHICH

DETAIL IS DRAWN

RE : 2 / M-201

REFER TO

DRAWING/DETAIL NUMBER

X

M-XXX

(U) AAA

(E) AAA

MAKE-UP WATERMU

PIPE TO BE REMOVED, "AAA" DENOTES TYPE

REFRIGERANT LIQUIDRL

REFRIGERANT SUCTIONRS

EXISTING PIPE, "AAA" DENOTES TYPE

UNDERGROUND PIPE, "AAA" DENOTES TYPE(U) AAA

DUAL TEMPERATURE SUPPLYDTS

DUAL TEMPERATURE RETURNDTR

PROCESS CHILLED W ATER RETURNPCWR

PROCESS CHILLED WATER SUPPLYPCWS

(E) - EXISTING

DAMPER TYPE:

FD

SD

FSD

BD

M

HVAC DESIGN CRITERIA

PROJECT: AFMC HQ RENOVATION PHASE 1 WRIGHT-PATTERSON AFB DAYTON, OHIO

DESIGN CONDITIONS PER UFC 3-400-02, 3-410-01

WEATHER STATION - WRIGHT-PATTERSON AFB, OHIO

STATION #: 745700

ELEVATION: 824 FEET; LATITUDE: 39.83°N; LONGITUDE: 84.05°W

ASHRAE CLIMATE ZONE 5A

WINTER: 8°F DRY BULB (99%)

SUMMER: DRY BULB CONDITIONS: HUMIDITY RATIO:

88°F DRY BULB(1.0%) 83°F DRY BULB

73°F MEAN COINCIDENT WET BULB 126 GR/LB (1.0%)

INDOOR DESIGN CONDITIONS PER UFC 3-410-01 AND UFC 3-580-01

WINTER: 68°F DB ± 2°F (OFFICE/ADMIN AREAS)

55°F DB ± 2°F (UNOCCUPIED SPACES)

SUMMER: 78°F DB ± 2°F & 55°F DP (OFFICE/ADMIN AREAS)

85°F DB (UNOCCUPIED SPACES)

ENERGY CODE COMPLIANCE

THE MECHANICAL AND PLUMBING EQUIPMENT IN THESE DRAWINGS ARE IN

COMPLIANCE WITH ASHRAE 90.1-2013. THE HVAC LOADS WERE PERFORMED IN

ACCORDANCE WITH ASHRAE FUNDAMENTALS. ENERGY CALCULATIONS WERE

PERFORMED IN ACCORDANCE WITH ASHRAE 90.1-2013.

EXISTING / DEMO / NEW SYMBOLS

(EQUIPMENT / DUCT)

EXISTING EQUIPMENT / DUCT TO REMAIN

EXISTING EQUIPMENT / DUCT TO BE DEMOLISHED

NEW EQUIPMENT / DUCT

(U) - UNDERGROUND

RE: - REFER TO

RF SHIELDING DUCTW ORK

PENETRATION SYMBOLS

MB

SM

NMC

MAN BARS

SOUND MASKING DEVICE

NON-CONDUCTIVE BREAK

CONSTRUCTION BARRIER (ONE HOUR FIRE RATED)

ONE HOUR FIRE RATED WALL

TW O HOUR FIRE RATED WALL

SOUND RATED PARTITION

CONSTRUCTION W ALL LEGEND

DUCT STATIC SENSORSS

CONTROL VALVE W / PETES PLUG(PICCV)

H2 HYGROGEN GAS (H2) DETECTOR/SENSOR

FD

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5

D

C

B

A

CUI

CUI

C U

I

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E D

A Y

T O

N

O H

IO

R E

P A

IR

/R

E N

O V

A T

E A

F M

C H

Q B

U

IL

D

IN

G

B

P

H A

S E

B262 PHASE

P

N O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J

B E

N S

O N

M001

G E

N E

R A

L N

O T

E S

A

B B

R E

V

IA

T

IO

N S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

N

B

R O

A D

W A

Y S

T

L O

U

IS

M

O

Q

H U

A N

G

A

C L

E A

R

K

G

IL

L

O C

T O

B E

R

W

Q R

R

X X

X X

B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION

P H

A S

E

M E

C H

A N

IC

A

L

W

2Q R

R

_P la ns _P

H 1_

Vo l6

-0

DEMOLITION NOTES DEMOLITION NOTES, CONT.

MECHANICAL SYMBOL LEGEND (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)

1. VISIT AND CAREFULLY EXAMINE THE PORTIONS OF THE EXISTING

BUILDING AND SITE INCLUDED IN THE PROJECT SCOPE. BECOME

FAMILIAR WITH EXISTING CONDITIONS, DIFFICULTIES, AND PHASE

REQUIREMENTS.

2. PRIOR TO COMMENCEMENT OF DEMOLITION WORK:

3. COMPLY WITH APPLICABLE LAWS, ORDINANCES, SAFETY RULES AND

REGULATIONS, OSHA STANDARDS, AND GOVERNING BODIES HAVING

JURISDICTION.

4. ABATEMENT OF CONTAMINATED EQUIPMENT AND REMOVAL OF

HAZARDOUS MATERIALS MUST BE ACCOMPLISHED PRIOR TO

CONTRACTOR BEGINNING DEMOLITION WORK.

5. PROTECT BUILDING, PIPING, EQUIPMENT, ETC. WHICH IS TO REMAIN IN

PLACE FOR REUSE. REPAIR OR REPLACE EQUIPMENT AND SYSTEMS TO

BE REUSED WHICH ARE INADVERTENTLY DAMAGED DURING THE

DEMOLITION PROCESS, AT NO ADDITIONAL COST TO THE BASE CE

GROUP.

6. PROVIDE CLOSURE DEVICES FOR REMAINING SYSTEMS AND

EQUIPMENT AS INDICATED ON THE DEMOLITION DRAWINGS. VERIFY

THAT THE CLOSURE DEVICES HAVE BEEN PROVIDED PRIOR TO RE-

ENERGIZING SYSTEMS.

7. COORDINATE WITH CONTRACTING OFFICER GROUP AND DIVISION 1

SPECIFICATION FOR SALVAGEABLE MATERIALS AND EQUIPMENT.

8. DO NOT REUSE REMOVED PIPING, DUCTW ORK, VALVES, ETC. UNLESS

SPECIFICALLY INDICATED OTHERWISE.

9. REMOVE EXISTING EXHAUST AIR DUCTWORK W ITHIN PHASE 1

CONSTRUCTION AREAS (TYPICAL UNLESS OTHERWISE NOTED).

EXHAUST DUCT UP TO ROOF-MOUNTED EXHAUST FANS MUST BE CUT

RIGHT BELOW ROOF.

10. REMOVE ALL EXISTING TERMINAL AIR UNITS (WITHIN PHASE 1

CONSTRUCTION AREAS), ASSOCIATED DUCTS, AND CONTROLS (TYPICAL

UNLESS OTHERWISE NOTED).

11. REMOVE EXISTING GRILLES AND SLOT DIFFUSERS WITHIN PHASE 1

CONSTRUCTION AREAS (TYPICAL UNLESS OTHERWISE NOTED).

12. FIRE DAMPERS, FIRE/SMOKE DAMPERS, MOTORIZED, MANUAL

BALANCING DAMPERS ASSOCIATED WITH DEMOLISHED DUCTWORK

MUST BE REMOVED.

13. PRIOR TO THE REMOVAL OF MEP ITEMS OF EQUIPMENT, VERIFY THE

ORIGIN AND TERMINATION OF THOSE SYSTEMS AND CONFIRM THAT THE

ITEMS BEING REMOVED DO NOT SERVE ITEMS THAT ARE TO REMAIN

(INCLUDING THOSE IN AREAS OUTSIDE OF THE CONTRACT LIMITS).

14. COORDINATE DEMOLITION WORK WITH THE CONTRACTING OFFICER

GROUP AND OTHER TRADES PERFORMING WORK IN THE BUILDING

PRIOR TO REMOVAL OF ITEMS OF EQUIPMENT OR SYSTEMS THAT WILL

AFFECT OTHER SYSTEMS WITHIN THE LIMIT OF THE NEW

CONSTRUCTION OR OTHER AREAS OF THE BUILDING.

15. REFER TO G-100 SERIES DRAWINGS FOR SEQUENCING OF WORK.

16. DUCTWORK REMOVAL TO INCLUDE, BUT IS NOT LIMITED TO, THE

COMPLETE REMOVAL OF RELATED INSULATION FITTINGS, AIR

DISTRIBUTION CONTROLS, AND SUPPORTS.

17. PIPING REMOVAL TO INCLUDE, BUT IS NOT LIMITED TO, THE COMPLETE

REMOVAL OF RELATED INSULATION FITTINGS, VALVE CONTROLS, AND

SUPPORTS.

18. EQUIPMENT REMOVAL TO INCLUDE, BUT IS NOT LIMITED TO, THE

COMPLETE REMOVAL OF RELATED INSULATION, ELECTRICAL POWER

CONNECTIONS, STARTERS, DRAINS, CONTROLS, VIBRATION ISOLATION,

MEASURES, AND SUPPORTS.

19. EXISTING PNEUMATIC CONTROLS ASSOCIATED WITH HVAC EQUIPMENT

BEING DEMOLISHED (WITHIN PHASE 1 CONSTRUCTION AREAS), WILL BE

DEMOLISHED AND REPLACED WITH DIGITAL CONTROLS. PNEUMATIC AIR

MAINS THAT SERVE EXISTING HVAC EQUIPMENT TO REMAIN, MUST

REMAIN IN OPERATION UNTIL EACH PHASE OF CONSTRUCTION IS

COMPLETED.

20. PRIOR TO SHUTDOW N OF AIR HANDLING UNITS, COORDINATE WITH

CONTRACTING OFFICER GROUP. THOSE THAT WILL REMAIN IN

OPERATION TO SERVE CONSTRUCTION SPACES MUST BE PROTECTED

PER BASE REQUIREMENT.

22. TAKE EXTRA PRECAUTION DURING DEMOLITION OF DUCTWORK

ROUTED INSIDE STRUCTURAL MEMBERS AS TO NOT DAMAGE OTHER

SYSTEMS THAT WILL REMAIN IN OPERATION. DUCTWORK DEMOLITION

WORK MUST BE COORDINATED AS NOT TO DISRUPT DATA, SECURITY,

CONTROL, OR FIRE ALARM CABLING WHICH MAY REMAIN IN OPERATION

AND SERVE AREAS OF THE BASE BUILDING.

23. AIR HANDLING UNITS THAT WILL REMAIN IN OPERATION DURING

CONSTRUCTION MUST BE PROVIDED WITH CONSTRUCTION FILTERS,

WITH MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8.

24. MAINTAIN NEGATIVE PRESSURE (MINIMUM 0.01 IN W.C.)WITHIN THE

CONSTRUCTION AREAS AS REFERENCED TO NON-CONSTRUCTION

AREAS AT ALL TIMES. DIFFERENTIAL PRESSURE MUST BE MONITORED

(VIA MAGNEHELIC GAUGES). VISUAL ALARMS MUST BE PROVIDED SUCH

THAT LOSS OF NEGATIVE PRESSURE TO THE CONSTRUCTION AREAS

WILL BE KNOWN IMMEDIATELY TO THE CONTRACTOR. IN THE EVENT THE

NEGATIVE PRESSURE IS COMPROMISED, CEASE CURRENT ACTIVITIES

AND TAKE IMMEDIATE ACTION TO ADDRESS THE CAUSE. EXHAUST

PROVIDED IN CONSTRUCTION AREAS WHERE GRINDING, W ELDING,

TOXIC FUMES, ETC. IS PRESENT MUST BE VENTED OUTSIDE OF

BUILDING AT LEAST 10 FT ABOVE GRADE AND AW AY FROM INTAKES IN

OPERATION. INSTITUTE AIR SAMPLING AND MONITORING ON THE NON-

CONSTRUCTION SIDE OF THE CONSTRUCTION BARRIER. THE ABOVE

REQUIREMENTS WILL BE MAINTAINED THROUGHOUT THE ENTIRE

DURATION OF CONSTRUCTION.

25. THE PROJECT/CONSTRUCTION SITE MUST BE COMPLETELY CONTAINED

WITH CONSTRUCTION BARRIERS. PROVIDE TEMPORARY FILTRATION ON

DUCTS ENTERING OR EXITING THE CONSTRUCTION ZONE. THIS AREA

MUST BE CLEANED USING HIGH-EFFICIENCY PARTICULATE AIR (HEPA)

FILTERED VACUUM CLEANERS PRIOR TO OCCUPANCY.

26. DEACTIVATION, RELOCATION, AND NEW WORK MUST BE PLANNED TO

MINIMIZE DISRUPTION OF BASE OFFICE FUNCTIONS. PROVIDE

TEMPORARY CAPPING AND CONNECTIONS AS REQUIRED TO MAINTAIN

EXISTING SYSTEMS DURING CONSTRUCTION. COORDINATE

SHUTDOWNS WITH CONTRACTING OFFICER GROUP.

27. DEBRIS REMOVAL FROM THE CONSTRUCTION SITE MUST BE

PERFORMED USING A PREDETERMINED ROUTE AND AT TIMES WHEN

THE CORRIDORS OR ELEVATORS ARE NOT IN USE.

28. DEMO EXISTING CHILLED WATER AND HEATING WATER PIPING SHOWN

AS DASHED, TYP.

29. DEMOLISH EXISTING SYSTEMS, EQUIPMENT, ETC AS INDICATED TO

MAKE WAY FOR NEW CONSTRUCTION. SCHEDULE WITH OWNER TO

MINIMIZE DISRUPTION.

30. PRIOR TO DEMOLITION, FIELD VERIFY AND IDENTIFY EXISTING

EQUIPMENT TO REMAIN IN SERVICE THAT IS SERVED BY SYSTEMS TO BE

DEMOLISHED. NOTIFY OWNER OF SUCH CONDITIONS AND REMOVE

AND/OR RELOCATE THE SERVICES AS DIRECTED.

31. MEET THE CONTRACTING OFFICER PRIOR TO DEMOLITION TO IDENTIFY

WHETHER EXISTING MATERIALS, SYSTEMS, EQUIPMENT, ETC ARE

CONSIDERED SALVAGE OR DEBRIS FROM SITE AND DISPOSE OF IN

APPROVED MANNER.

32. DEMO COMPRESSED AIR PIPING BACK TO VALVE. LOCATE ISOLATION

VALVE TO SHUT OFF SERVICE TO COMPLETE DEMO AND COORDINATE

OTHER INTERRUPTION SERVICES WITH OWNER PRIOR TO DEMOLITION.

33. PROVIDE ISOLATION VALVES BETWEEN ACTIVE PIPING TO REMAIN AND

PIPING TO BE DEMOLISHED WHERE VALVES DO NOT ALREADY EXIST.

REFER TO SPECIFICATION FOR VALVE TYPES.

34. WHERE REMOVAL OF PIPING REQUIRES TEMPORARY REMOVAL OF

SYSTEMS OR MATERIALS TO REMAIN, SUCH AS CEILING TILES, SUCH

SYSTEMS MUST BE REPLACED AND RETURNED TO AS-FOUND

CONDITIONS.

35. EQUIPMENT PIPING DEMOLITION: DETAILS OR DEMOLITION OF PIPING

LOCAL TO EQUIPMENT ARE NOT SHOWN. REMOVE MISCELLANEOUS

HYDRONIC PIPING CONNECTED TO EQUIPMENT TO BE REMOVED.

36. PIPE SIZES SHOWN W ERE OBTAINED FROM AS-BUILT DRAWINGS, AND

FROM VISUAL INSPECTION WITH INSULATION ON PIPING, AND MUST

THEREFORE BE CONSIDERED AS APPROXIMATE.

MECHANICAL/ELECTRICAL SYSTEM COORDINATION SCHEDULE

SYSTEM

FURNISHED

BY

INSTALLED

BY

POWER

WIRING BY

CONTROL OR

SUPERVISION WIRING BY

MAIN FUEL OIL SYSTEM

-----> FUEL OIL ALARM - AST

-----> FUEL OIL ALARM

LIFE SAFETY SYSTEM

-----> SMOKE SAMPER/ACTUATOR

-----> FIRE/SMOKE DAMPER/ACTUATOR

-----> DUCT SMOKE DETECTOR (INCLUDES AHU)

CHEMICAL FEED SYSTEM

DOMESTIC WATER BOILERS

MOTOR STARTERS (INTEGRAL TO EQUIP.)

MOTOR STARTERS (NON-INTEGRAL TO EQUIP.)

COMBINATION MOTOR STARTER/DISCONNECT (INTEGRAL TO EQUIP.)

COMBINATION MOTOR STARTER/DISCONNECT (NON-INTEGRAL TO EQUIP.)

VARIABLE FREQUENCY DRIVES (VFD'S)

DISCONNECT SWITCHES (NON-INTEGRAL TO EQUIP.)

HEAT TRACE

DIV 23 DIV 23 DIV 26 DIV 23

DIV 23

DIV 23

DIV 23

DIV 23

DIV 28

DIV 22/23

DIV 22

DIV 22/23

DIV 26

DIV 22/23

DIV 26

DIV 23

DIV 26

DIV 22/23

DIV 23 --

DIV 23 DIV 26

DIV 23

DIV 23

DIV 23

DIV 22/23

DIV 22

DIV 26

DIV 26

DIV 26

DIV 26

DIV 22/23

DIV 26

DIV 26

DIV 26

DIV 26

DIV 26

DIV 26

DIV 26

DIV 26

DIV 26

DIV 26

DIV 26

DIV 23

DIV 22/26

DIV 28

DIV 28

DIV 28

DIV 22/23

DIV 23

DIV 23

DIV 23

DIV 23

DIV 23

DIV 23

DIV 23

FIELD VERIFY THE SIZES AND LOCATION OF EQUIPMENT AND

SYSTEMS TO BE REMOVED.

VERIFY THAT EQUIPMENT AND SYSTEMS HAVE BEEN DE-

ENERGIZED AND ARE SAFE TO DISMANTLE. COMPLY WITH EM

385-1-1 AND CONSTRUCTION SITE LOCK-OUT/TAG-OUT

PROCEDURES.

VERIFY THAT THE DEMO AREA IS ACCESSIBLE AND THAT

DEMO TRAFFIC ROUTES ARE FREE AND CLEAR.

PROVIDE A DEMOLITION PLAN TO USACE COR OUTLINING

SCHEDULED WORK AND ACTIVITIES, REQUIRED OUTAGES,

AND SAFETY CONCERNS. IDENTIFY ELEMENTS OF RISK

ASSOCIATED WITH THE DEMOLITION WORK AND PROVIDE

CONTINGENCY PLANS TO MINIMIZE THE RISK TO THE

PROJECT.

CONTRACTOR MUST UNDERSTAND PHASING CONSTRUCTION

BARRIER SHOWN IN THIS PHASE. AREAS BETWEEN PHASING

CONSTRUCTION BARRERS WILL REQUIRE SPECIAL

CONSIDERATION SUCH THAT OPERATIONAL EQUIPMENT IN

ADJACENT SPACES WILL REMAIN OPERATIONAL.

CONTRACTOR MUST UNDERSTAND SCHEDULE AND WHEN

SYSTEMS CAN BE DEMOLISHED. SOME EQUIPMENT AND

AREAS REQUIRE SPECIAL PHASING OR IMMEDIATE

REPLACEMENT WITH NEW EQUIPMENT TO MAINTAIN

OPERATION.

A.

B.

C.

D.

E.

F.

MECHANICAL SEQUENCING CONSIDERATIONS

• BLDG 264 RECONDITIONING MUST BE COMPLETED BEFORE BLDG 264

MECHANICAL EQUIPMENT IS INSTALLED.

• CONDENSER AND HEATING WATER PIPES MUST BE ROUTED TO BLDG

264 BEFORE BLDG 264 MECHANICAL EQUIPMENT IS INSTALLED.

• A-SWITCH ROOM MUST NOT LOSE COOLING FOR MORE THAN 2 HOURS.

ESTIMATED COOLING LOAD FOR A-SWITCH IS 60 TONS.

• CHILLED WATER AND HEATING WATER PIPING SWITCHOVER MUST BE

SCHEDULED AS TO NOT DISRUPT BUILDING OPERATIONS.

• DUCTWORK MODIFICATIONS FOR (E) AHU-6 AND (E) AHU-7 MUST BE

COMPLETED BEFORE ASSOCIATED DEMOLITION STARTS.

• AHU-104 MUST BE IN OPERATION BEFORE (E) AHU-22 CAN BE REMOVED.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5

D

C

B

A

CUI

CUI

C U

I

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E D

A Y

T O

N

O H

IO

R E

P A

IR

/R

E N

O V

A T

E A

F M

C H

Q B

U

IL

D

IN

G

B

P

H A

S E

B262 PHASE

P

N O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J

B E

N S

O N

M002

G E

N E

R A

L N

O T

E S

A

B B

R E

V

IA

T

IO

N S

C O

N T

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

N

B

R O

A D

W A

Y S

T

L O

U

IS

M

O

Q

H U

A N

G

A

C L

E A

R

K

G

IL

L

O C

T O

B E

R

W

Q R

R

X X

X X

B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION

P H

A S

E

M E

C H

A N

IC

A

L

W

2Q R

R

_P la ns _P

H 1_

Vo l6

-0

(U)HWR

(U)HWS

(U)HWR

(U)CWS

(U)CWR

(U)HWS

A. EXCAVATE AND VERIFY ELEVATIONS OF EXISTING UTILITIES PRIOR TO START

OF CONSTRUCTION.

B. COORDINATE WITH THE CIVIL SITE PLAN AND ELECTRICAL SITE PLAN TO

AVOID THE CONFLICTS WITH THE PROPOSED STORM LINES AND

ELECTRICAL DUCT BANKS.

SHEET NOTES - SITE PLAN

KEYED NOTES - SITE PLAN #

BUILDING 10264

BUILDING 10263

BUILDING 10262

019019

018018

017017

016016

015015

N

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5

D

C

B

A

20'10' 40'

CUI

CUI

C U

I

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E D

A Y

T O

N

O H

IO

R E

P A

IR

/R

E N

O V

A T

E A

F M

C H

Q B

U

IL

D

IN

G

B

P

H A

S E

B262 PHASE

P

N O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J

B E

N S

O N

MS-101

S

IT

E U

T

IL

IT

Y

P L

A N

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

N

B

R O

A D

W A

Y S

T

L O

U

IS

M

O

Q

H U

A N

G

A

C L

E A

R

K

G

IL

L

O C

T O

B E

R

W

Q R

R

X X

X X

B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION

P H

A S

E

M E

C H

A N

IC

A

L

1" = 20'-0" A1

SITE UTILITY PLAN - MECHANICAL

014 PROVIDE A SET OF ISOLATION VALVES FOR THE EXISTING 10" HEATING

WATER PIPES INSIDE TUNNEL AND EXTEND THE PIPES UNDERGROUND

FURTHER EAST.

015 AFTER THE HEATING WATER SERVING BLDG 262 BROUGHT ONLINE, REMOVE

THE EXISTING 10" HEATING WATER PIPES AS SHOWN DASHED AND

TERMINATE WITH A SET OF ISOLATION VALVES AT THE LOCATION AS

INDICATED.

016 AFTER THE CHILLED WATER SYSTEM SERVING THE EXISTING LOOPS

BROUGHT ON LINE, REMOVE THE EXISTING 20" CONDENSER WATER PIPES AS

SHOWN DASHED OUT OF GROUND TO THE LOCATION AND TERMINATE WITH A

SET OF ISOLATION VALVES.

017 ROUTE NEW 20" CONDENSER WATER PIPES OFF THE NEW TEE FITTING TO

THE NEW CHILLERS LOCATED IN BLDG 264.

018 ROUTE THE NEW DIRECT BURIED 10" HEATING WATER PIPES TO THE NEW

HEATING WATER PUMPS LOCATED IN BLDG 264.

019 ROUTE ONE 20" CWS AND TWO 10" HWS/R UNDER GRADE BEAM INTO BLDG 264

020 ROUTE ONE 20" CWR OUT OF WEST WALL AND DOWN TO UNDERGROUND.

021 ANCHOR BLOCK PROVIDED BY THE UNDERGROUND PREINSULATED PIPING

VENDOR.

022 14'-0" X 7'-0" EXPANSION LOOP

023 REFER TO CU302 & CU303 FOR CONDENSER WATER PIPES AND HEATING

WATER PIPES INVERT ELEVATION.

W

2Q R

R

_P la ns _P

H 1_

Vo l6

-0

EXISTING CHW LOOP 4

EXISTING CHW LOOP 2

EXISTING CHW LOOP 3

EXISTING CHW LOOP 4

SHEET NOTES - OVERALL DEMOLITION PLANS

A OVERALL PLANS FOR REFERENCE ONLY. REFER TO AREA PLANS FOR

DETAILED SYSTEMS.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5

D

C

B

A

CUI

CUI

C U

I

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E D

A Y

T O

N

O H

IO

R E

P A

IR

/R

E N

O V

A T

E A

F M

C H

Q B

U

IL

D

IN

G

B

P

H A

S E

B262 PHASE

P

N O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J

B E

N S

O N

MD100A

O V

E R

A L

L D

E M

O L

IT

IO

N P

L A

N

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

N

B

R O

A D

W A

Y S

T

L O

U

IS

M

O

Q

H U

A N

G

A

C L

E A

R

K

G

IL

L

O C

T O

B E

R

W

Q R

R

X X

X X

B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION

B A

S E

M E

N T

P

H A

S E

M E

C H

A N

IC

A

L

1/32" = 1'-0" A1

BASEMENT DEMOLITION PLAN - OVERALL

N

0 16' 32' 64'

EXISTING HW LOOP 5

EXISTING HW LOOP 3

EXISTING HW LOOP 4

EXISTING HW LOOP 6A

EXISTING HW LOOP 7A

EXISTING HW LOOP 6B

EXISTING HW LOOP 7B

EXISTING HW LOOP 8

W

2Q R

R

_P la ns _P

H 1_

Vo l6

-0

G

F

E

D

C

B

A

18 19 20 21 22 23 24 25

(E) 12"ø

(E

"ø

(E

"ø

(E) 18"x12"(E) 18"x18"(E) 24"x18"(E) 22"x22" (E

"x

(E) 8"ø

(E) 2 1/2"

(E) 2 1/2"

(E) 3" CHWS

(E) 3" CHWR

(E) 3"

(E) 3"

(E) 5" HWS

(E) 5" HWR

(E) 2 1/2" CHWS

(E) 2 1/2" CHWR

(E) 2 1/2" CHWS

(E) 2 1/2" CHWR

(E

/2

(E

/2

(E

/4

C H

W S

(E

/4

C H

W R

(E) 3" CHWR

(E) 3" CHWS

(E) 3" CHWS

(E) 3" CHWR

(E) 3" CHWR

(E) 3" CHWS

(E) 3"

(E) 3"

(E) 3"

(E) 3"

CHWS

CHWR

C H

W S

C H

W R

HWR

HWS

CHWR

CHWS

HWR

HWS

SA SA

SA

SA

S A

SA

S A

C H

W S

C H

W R

CHWR

CHWS

SA

(E) CRAC-1

(E) CRAC-8

(E) AHU-35

(E) 5" CHWS

(E) 5" CHWR

MATCHLINE

A1 MD102A

M A

T C

H

LI

N E

A

M D

4A

EXISTING CHW

PIPING CAP

(E

/4

C H

W S

(E

/4

C H

W R

(E

(E

(E) CHW LOOP 2

(E

C H

W L

O O

P

D201D201

D202D202

D85D85

STAIR 6

(E) CRAC-3

D222

(E) 2 1/2"

(E) 2 1/2"

(E) 2 1/2"

(E) 2 1/2" CHWR

CHWS

(E) CRAC-4

D231

D229

D230

(E) CRAC-2

D232

D233

D235

D234

D202D202 D202D202

(E) 5" CHWR

(E) 5" CHWS

(E) 5" CHWS

(E) 5" CHWR

(E) 4" CHWR

(E) 4" CHWS

D235

(E) 3" CHWR

(E) 3" CHWS

(E) 3" CHWS

(E) 3" CHWR

(E) RS/RL

PIPING

(E) RS/RL

PIPING

(E) RS/RL

PIPING

D245

R A

(E) 10"øEA

(E) 18"øEA

EA(E) 14"ø

KEYED NOTES - DEMO PLAN #

A. DEMOLISH DASHED EQUIPMENT, DUCTWORK, DIFFUSERS, PIPING, VALVES

AND ASSOCIATED CONTROLS AS SHOWN.

B. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR PATCHING

OF STRUCTURE OPENINGS, EQUIPMENT HOUSEKEEPING PAD REMOVAL,

SUPPORT HANGER REMOVAL, TRENCHES AND SUMP BACKFILLING AS THE

RESULT OF DEMOLISHED MECHANICAL ITEMS.

C. REMOVE HOUSEKEEPING PADS AND SUPPORT HANGERS ASSOCIATED WITH

DEMOLISHED MECHANICAL EQUIPMENT. PATCH FLOOR TO MATCH EXISTING

FINISH. REFER TO SHEET S-100 GENERAL NOTES, DIVISION 3, CONCRETE,

NOTE 2.2M.

D. REMOVE PNEUMATIC CONTROL TUBING SERVING VAV BOX ACTUATORS AND

THERMOSTATS THAT ARE TO BE DEMOLISHED. CAP CONTROL TUBING AT

PNEUMATIC MAIN. PNEUMATIC CONTROL TUBING REMOVAL MUST NOT

INTERRUPT THE OPERATION OF AREAS THAT ARE NOT UNDER CURRENT

CONSTRUCTION PACKAGE. WHERE INTERRUPTION CANNOT BE AVOIDED,

COORDINATE DOWNTIME WITH COR FOUR WEEKS PRIOR TO MINIMIZE

MISSION IMPACT.

E. THE PROPOSED DEMO SCOPE AS SHOWN IS COMPILED FROM VARIOUS

CONSTRUCTION DOCUMENTS ACCUMULATED IN PAST DECADES. IF

DISCREPANCIES ARE FOUND BETW EEN THE AS-BUILTS USED IN THE DESIGN

AND ACTUAL UTILITY LOCATIONS, NOTIFY THE COR.

F. MAINTAIN FUNCTIONALITY OF THE EXISTING HEATING WATER REVERSE

RETURN SYSTEM DURING THE DEMOLITION PHASE (IF APPLICABLE).

G. COORDINATE CONSTRUCTION SCHEDULE FOR SCOPE OF WORK UNDER THE

SHADED AREA (IF APPLICABLE), TO MINIMIZE IMPACT TO NORMAL

OPERATION OF THE FACILITY.

SHEET NOTES - DEMO PLAN

LEGEND

SHADED AREA IS NOT UNDER CURRENT CONSTRUCTION

PACKAGE UNLESS OTHERWISE NOTED - WORK TO BE

PERFORMED IN THE SHADED AREAS WILL NEED TO BE

COORDINATED WITH COR FOUR WEEKS PRIOR TO MINIMIZE

MISSION IMPACT

KEY PLAN

N

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5

D

C

B

A

CUI

CUI

C U

I

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E D

A Y

T O

N

O H

IO

R E

P A

IR

/R

E N

O V

A T

E A

F M

C H

Q B

U

IL

D

IN

G

B

P

H A

S E

B262 PHASE

P

N O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J

B E

N S

O N

MD101A

A R

E A

D E

M O

L

IT

IO

N

P L

A N

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

N

B

R O

A D

W A

Y S

T

L O

U

IS

M

O

Q

H U

A N

G

A

C L

E A

R

K

G

IL

L

O C

T O

B E

R

W

Q R

R

X X

X X

B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION

B A

S E

M E

N T

A

R E

A

P

H A

S E

M E

C H

A N

IC

A

L

1/8" = 1'-0" A1

BASEMENT DEMOLITION PLAN - AREA 1

D85 CAP PIPE AND SEAL WATERTIGHT

D201 EXISTING 3" HWS/R UP SERVING FIRST FLOOR EXISTING HW LOOP 11, SECOND

FLOOR EXISTING HW LOOP 12 AND 14 TO BE REMOVED. CAP VERTICAL PIPES

UNDERNEATH FIRST FLOOR SLAB. PATCH FLOOR OPENING TO MATCH

EXISTING. RE: S001 DIVISION 3 - CONCRETE.

D202 CAP CHWS/R. RE: A1 / MP101A FOR HOT TAP CONNECTION. CHILLED WATER

SERVICE SERVING EXISTING A SWITCH ROOM MUST NOT BE DISRUPTED.

D222 RELOCATE (E) CRAC-3 AS SHOWN ON A1/MP101A. DISCONNECT AND REROUTE

ASSOCIATED CHW, REFRIGERANT, CONDENSATE, AND CONTROL/ELECTRICAL

WIRING.

D227 REMOVE SIXTEEN (16) ABOVE-GROUND REFRIGERANT PIPES FROM EXTERIOR

WALL PENETRATIONS TO ASSOCIATED CONDENSING UNITS ADJACENT TO

BLDG 263. PROVIDE CAPS AT STUB OUTS THROUGH EXTERIOR WALL.

REMOVED PIPES MUST BE PROTECTED FROM CONTAMINANTS FOR REUSE.

D229 EXISTING FOUR (4) REFRIGERANT PIPES SERVING (E) CRAC-2. PROVIDE AIR &

WATER-TIGHT CAPS AT STUB OUTS THROUGH EXTERIOR WALL. REFER TO

MD119B FOR CONTINUATION.

D230 EXISTING EIGHT (8) REFRIGERANT PIPES SERVING (E) CRAC-1 & (E) CRAC-3.

PROVIDE AIR & WATER-TIGHT CAPS AT SUB OUTS THROUGH EXTERIOR WALL.

REFER TO MD119B FOR CONTINUATION.

D231 EXISTING TWELVE (12) REFRIGERANT PIPES SERVING (E) CRAC UNITS 4,6 & 8.

PROVIDE AIR & WATER-TIGHT CAPS AT STUB OUTS THROUGH EXTERIOR

WALL. REFER TO MD119B FOR CONTINUATION.

D232 REMOVE EXISTING EXHAUST AIR DUCT & SIDE-WALL EXHAUST CAP AND

STORE FOR REUSE. SEAL EXTERIOR WALL PENETRATION TO FULL WALL

THICKNESS TO MATCH EXISTING. REFER TO MH101A FOR EXHAUST CAP

RELOCATION.

D233 CAP EXISTING REFRIGERANT PIPING SERVING (E) CRAC-4 AT CONSTRUCTION

BARRIER WALL.

D234 CAP EXISTING REFRIGERANT PIPING SERVING (E) CRAC-3 FOR REUSE. REFER

TO MP101A FOR CONNECTION.

D235 CAP EXISTING CHW PIPING SERVING (E) CRAC-3 FOR REUSE. REFER TO

MP101A FOR CONNECTION.

D245 PROTECT THE EXISTING EXHAUST DUCTWORK AND EXHAUST GRILLE IN

PLACE DURING PLUMBING PIPE DEMOLITION. RE: PD101A FOR PLUMBING

WORK.

W

2Q R

R

_P la ns _P

H 1_

Vo l6

-0

M

L

K

J

I

H

G

18 19 20 21 22 23 24 25

(E

"x

(E

"x

(E) 32"x16"

(E

"x

(E) 32"x24" (E) 24"x24"

(E) 14"x10"

(E

"x

(E

"x

(E) 16"x16"

(E

"x

(E

"x

(E

"ø

(E

"x

(E) 16"x16"

R

A RA RA

(E) 3"

(E) 3"

(E) 3"

(E) 3" HWR

HWS

CHWR

CHWS

SA

S A

S A

(E) 20"x18" SA

SA

(E

/2

(E

/2

H W

S

H W

R

SA

(E) 1 1/4"

(E) 1 1/4"

(E) 2"

HWR

HWS

HWR

(E) 3/4"

(E) 1 1/2" (E) 2"

HWS

HWR HWR

S A

R A

R A

S A

S A

S A

(E) AHU-23

D69

MATCHLINE

A1 MD103A

MATCHLINE

A1 MD101A

M A

T C

H

LI

N E

A

M D

5A

SA

D200D200

D82

D85D85 D03

(E

"x

S A

(E

"x

S A

(E) 10"ø SA

R A

EA

EA(E) 14"ø

D82

D246D246D246

KEYED NOTES - DEMO PLAN #

A. DEMOLISH DASHED EQUIPMENT, DUCTWORK, DIFFUSERS, PIPING, VALVES

AND ASSOCIATED CONTROLS AS SHOWN.

B. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR PATCHING

OF STRUCTURE OPENINGS, EQUIPMENT HOUSEKEEPING PAD REMOVAL,

SUPPORT HANGER REMOVAL, TRENCHES AND SUMP BACKFILLING AS THE

RESULT OF DEMOLISHED MECHANICAL ITEMS.

C. REMOVE HOUSEKEEPING PADS AND SUPPORT HANGERS ASSOCIATED WITH

DEMOLISHED MECHANICAL EQUIPMENT. PATCH FLOOR TO MATCH EXISTING

FINISH. REFER TO SHEET S-100 GENERAL NOTES, DIVISION 3, CONCRETE,

NOTE 2.2M.

D. REMOVE PNEUMATIC CONTROL TUBING SERVING VAV BOX ACTUATORS AND

THERMOSTATS THAT ARE TO BE DEMOLISHED. CAP CONTROL TUBING AT

PNEUMATIC MAIN. PNEUMATIC CONTROL TUBING REMOVAL MUST NOT

INTERRUPT THE OPERATION OF AREAS THAT ARE NOT UNDER CURRENT

CONSTRUCTION PACKAGE. WHERE INTERRUPTION CANNOT BE AVOIDED,

COORDINATE DOWNTIME WITH COR FOUR WEEKS PRIOR TO MINIMIZE

MISSION IMPACT.

E. THE PROPOSED DEMO SCOPE AS SHOWN IS COMPILED FROM VARIOUS

CONSTRUCTION DOCUMENTS ACCUMULATED IN PAST DECADES. IF

DISCREPANCIES ARE FOUND BETW EEN THE AS-BUILTS USED IN THE DESIGN

AND ACTUAL UTILITY LOCATIONS, NOTIFY THE COR.

F. MAINTAIN FUNCTIONALITY OF THE EXISTING HEATING WATER REVERSE

RETURN SYSTEM DURING THE DEMOLITION PHASE (IF APPLICABLE).

G. COORDINATE CONSTRUCTION SCHEDULE FOR SCOPE OF WORK UNDER THE

SHADED AREA (IF APPLICABLE), TO MINIMIZE IMPACT TO NORMAL

OPERATION OF THE FACILITY.

SHEET NOTES - DEMO PLAN

LEGEND

SHADED AREA IS NOT UNDER CURRENT CONSTRUCTION

PACKAGE UNLESS OTHERWISE NOTED - WORK TO BE

PERFORMED IN THE SHADED AREAS WILL NEED TO BE

COORDINATED WITH COR FOUR WEEKS PRIOR TO MINIMIZE

MISSION IMPACT

KEY PLAN

N

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5

D

C

B

A

8'4' 16'

CUI

CUI

C U

I

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E D

A Y

T O

N

O H

IO

R E

P A

IR

/R

E N

O V

A T

E A

F M

C H

Q B

U

IL

D

IN

G

B

P

H A

S E

B262 PHASE

P

N O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J

B E

N S

O N

MD102A

A R

E A

D E

M O

L

IT

IO

N

P L

A N

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

N

B

R O

A D

W A

Y S

T

L O

U

IS

M

O

Q

H U

A N

G

A

C L

E A

R

K

G

IL

L

O C

T O

B E

R

W

Q R

R

X X

X X

B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION

B A

S E

M E

N T

A

R E

A

P

H A

S E

M E

C H

A N

IC

A

L

1/8" = 1'-0" A1

BASEMENT DEMOLITION PLAN - AREA 2

D03 CAP DUCTWORK AT FUTURE SCOPE AREA NEXT TO CONSTRUCTION BARRIER

WALL AND SEAL AIRTIGHT.

D69 REMOVE EXISTING DUCTWORK. REMOVE ASSOCIATED INSULATION, FITTINGS,

AND SUPPORTS. TYPICAL AS SHOWN DASHED.

D82 CAP DUCT AND SEAL AIRTIGHT. PROVIDE INSULATED END CAP.

D85 CAP PIPE AND SEAL WATERTIGHT

D200 EXISTING 1-1/2" HWS/R UP SERVING SECOND FLOOR EXISTING HW LOOP 15 TO

BE REMOVED. CAP VERTICAL PIPES WATERTIGHT UNDERNEATH FIRST FLOOR

SLAB. RE: MD102B FOR EXTENT OF DEMO.

D246 EXISTING DUCT TO REMAIN IN PLACE. CONSTRUCTION ZONE BARRIER TO BE

CONSTRUCTED AROUND EXISTING DUCT. PROVIDE FIRE CAULK AT

PENETRATION LOCATION TO SEAL THE PENETRATION TO BE AIR-TIGHT. NO

AIR INLET OR OUTLET SHOULD BE LEFT IN PLACE IN THE CONSTRUCTION

ZONE.

W

2Q R

R

_P la ns _P

H 1_

Vo l6

-0

T

S

R

Q

P

O

N

18 19 20 21 22 23 24 25

(E

"ø

(E) 38"x26"

(E

"x

(E) 20"x18"

(E

"x

(E

"x

(E) 42"x22"

(E

"x

(E) 34"x18"

(E

"ø

(E) 16"x10"

S A

SA

S A

R A

SA

SA

S A

RARA

R A

(E) 1/2"

(E) 1/2" HWS

HWR

S A

MATCHLINE

A1 MD102A

M A

T C

H

LI

N E

A

M D

6A

STAIR 5

(E

"x

S A

(E) 48"x26"(E) 56"x26" SASA

(E

"ø

(E

"ø

R A

R A

(E) 48"x28"

(E

"x

RA

R A

(E) 34"x24" (E) 18"ø

(E

"x

SA SAS

A

D225

D225

KEYED NOTES - DEMO PLAN #

A. DEMOLISH DASHED EQUIPMENT, DUCTWORK, DIFFUSERS, PIPING, VALVES

AND ASSOCIATED CONTROLS AS SHOWN.

B. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR PATCHING

OF STRUCTURE OPENINGS, EQUIPMENT HOUSEKEEPING PAD REMOVAL,

SUPPORT HANGER REMOVAL, TRENCHES AND SUMP BACKFILLING AS THE

RESULT OF DEMOLISHED MECHANICAL ITEMS.

C. REMOVE HOUSEKEEPING PADS AND SUPPORT HANGERS ASSOCIATED WITH

DEMOLISHED MECHANICAL EQUIPMENT. PATCH FLOOR TO MATCH EXISTING

FINISH. REFER TO SHEET S-100 GENERAL NOTES, DIVISION 3, CONCRETE,

NOTE 2.2M.

D. REMOVE PNEUMATIC CONTROL TUBING SERVING VAV BOX ACTUATORS AND

THERMOSTATS THAT ARE TO BE DEMOLISHED. CAP CONTROL TUBING AT

PNEUMATIC MAIN. PNEUMATIC CONTROL TUBING REMOVAL MUST NOT

INTERRUPT THE OPERATION OF AREAS THAT ARE NOT UNDER CURRENT

CONSTRUCTION PACKAGE. WHERE INTERRUPTION CANNOT BE AVOIDED,

COORDINATE DOWNTIME WITH COR FOUR WEEKS PRIOR TO MINIMIZE

MISSION IMPACT.

E. THE PROPOSED DEMO SCOPE AS SHOWN IS COMPILED FROM VARIOUS

CONSTRUCTION DOCUMENTS ACCUMULATED IN PAST DECADES. IF

DISCREPANCIES ARE FOUND BETW EEN THE AS-BUILTS USED IN THE DESIGN

AND ACTUAL UTILITY LOCATIONS, NOTIFY THE COR.

F. MAINTAIN FUNCTIONALITY OF THE EXISTING HEATING WATER REVERSE

RETURN SYSTEM DURING THE DEMOLITION PHASE (IF APPLICABLE).

G. COORDINATE CONSTRUCTION SCHEDULE FOR SCOPE OF WORK UNDER THE

SHADED AREA (IF APPLICABLE), TO MINIMIZE IMPACT TO NORMAL

OPERATION OF THE FACILITY.

SHEET NOTES - DEMO PLAN

LEGEND

SHADED AREA IS NOT UNDER CURRENT CONSTRUCTION

PACKAGE UNLESS OTHERWISE NOTED - WORK TO BE

PERFORMED IN THE SHADED AREAS WILL NEED TO BE

COORDINATED WITH COR FOUR WEEKS PRIOR TO MINIMIZE

MISSION IMPACT

KEY PLAN

N

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5

D

C

B

A

8'4' 16'

CUI

CUI

C U

I

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E D

A Y

T O

N

O H

IO

R E

P A

IR

/R

E N

O V

A T

E A

F M

C H

Q B

U

IL

D

IN

G

B

P

H A

S E

B262 PHASE

P

N O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J

B E

N S

O N

MD103A

A R

E A

D E

M O

L

IT

IO

N

P L

A N

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

N

B

R O

A D

W A

Y S

T

L O

U

IS

M

O

Q

H U

A N

G

A

C L

E A

R

K

G

IL

L

O C

T O

B E

R

W

Q R

R

X X

X X

B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION

B A

S E

M E

N T

A

R E

A

P

H A

S E

M E

C H

A N

IC

A

L

1/8" = 1'-0" A1

BASEMENT DEMOLITION PLAN - AREA 3

D225 RELOCATE EXISTING VAV, PIPING, DUCTWORK, AND HW PIPING AS NEEDED TO

ACCOMMODATE CONSTRUCTION BARRIER WALLS AND PIPING AS SHOWN ON

SHEETS P103A & P704.

W

2Q R

R

_P la ns _P

H 1_

Vo l6

-0

E

D

C

B

A

11 12 13 14 15 16 18 1917

(E) 14"x12"

(E

"x

O A

(E

"x

O A

(E) 66"x30"

(E

"x

(E

"x

(E

"x

(E

"x

S A

(E) 36"x18"

(E) 36"x30"

(E) 14"x18" (E) 14"x14"

(E) 44"x30" (E) 40"x26" (E) 34"x26"

SA

S A

(E) 6" CHWR

(E) 6" CHWS

(E) 5" HWS

(E) 5" HWR

SASA

RA

R A

(E) 3" HWR

(E) 3" HWS

S A

S A

(E) 5" HWS

S A

RA

SA SA SA

(E) 8"

(E) 8" CHWS

CHWR

(E) 12"

(E

CWR

C W

S

(E

(E

C

W R

C W

S

(E) 8"

(E) 8" CHWS

CHWR

(E) 5" HWR

(E) CRAC-6

REMOVED 20" UNDERGROUND CONDENSER

WATER PIPES TO LOCATION AS SHOWN ON

SHEET MS101.

D04

D223

(E) AHU-22

(E) CRAC-7

(E) CRAC-5

(E) CRAC-9

D70

D04

D112D112

D112

D112

D113D113

TYP.

D96D96

D111

MATCHLINE

A1 MD105A

M A

T C

H

LI

N E

A

M D

7A

M A

T C

H

LI

N E

A

M D

1A

BB

DD

EE

(E) AHU-23

(E

/4

C H

W S

(E

/4

C H

W R

(E

C H

W L

O O

P

(E

C H

W L

O O

P

D208

D208

D208

D85D85

D204

D208

D219D219

D224D224D224D224

D236

D237D237

D237

D202D202

(E) 5" CHWR

(E) 5" CHWS

(E) 5" CHWS

(E) 5" CHWR

(E) 3" CHWR

(E) 3" CHWS

(E

"x

R A

KEYED NOTES - DEMO PLAN #

A. DEMOLISH DASHED EQUIPMENT, DUCTWORK, DIFFUSERS, PIPING, VALVES

AND ASSOCIATED CONTROLS AS SHOWN.

B. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR PATCHING

OF STRUCTURE OPENINGS, EQUIPMENT HOUSEKEEPING PAD REMOVAL,

SUPPORT HANGER REMOVAL, TRENCHES AND SUMP BACKFILLING AS THE

RESULT OF DEMOLISHED MECHANICAL ITEMS.

C. REMOVE HOUSEKEEPING PADS AND SUPPORT HANGERS ASSOCIATED WITH

DEMOLISHED MECHANICAL EQUIPMENT. PATCH FLOOR TO MATCH EXISTING

FINISH. REFER TO SHEET S-100 GENERAL NOTES, DIVISION 3, CONCRETE,

NOTE 2.2M.

D. REMOVE PNEUMATIC CONTROL TUBING SERVING VAV BOX ACTUATORS AND

THERMOSTATS THAT ARE TO BE DEMOLISHED. CAP CONTROL TUBING AT

PNEUMATIC MAIN. PNEUMATIC CONTROL TUBING REMOVAL MUST NOT

INTERRUPT THE OPERATION OF AREAS THAT ARE NOT UNDER CURRENT

CONSTRUCTION PACKAGE. WHERE INTERRUPTION CANNOT BE AVOIDED,

COORDINATE DOWNTIME WITH COR FOUR WEEKS PRIOR TO MINIMIZE

MISSION IMPACT.

E. THE PROPOSED DEMO SCOPE AS SHOWN IS COMPILED FROM VARIOUS

CONSTRUCTION DOCUMENTS ACCUMULATED IN PAST DECADES. IF

DISCREPANCIES ARE FOUND BETW EEN THE AS-BUILTS USED IN THE DESIGN

AND ACTUAL UTILITY LOCATIONS, NOTIFY THE COR.

F. MAINTAIN FUNCTIONALITY OF THE EXISTING HEATING WATER REVERSE

RETURN SYSTEM DURING THE DEMOLITION PHASE (IF APPLICABLE).

G. COORDINATE CONSTRUCTION SCHEDULE FOR SCOPE OF WORK UNDER THE

SHADED AREA (IF APPLICABLE), TO MINIMIZE IMPACT TO NORMAL

OPERATION OF THE FACILITY.

SHEET NOTES - DEMO PLAN

LEGEND

SHADED AREA IS NOT UNDER CURRENT CONSTRUCTION

PACKAGE UNLESS OTHERWISE NOTED - WORK TO BE

PERFORMED IN THE SHADED AREAS WILL NEED TO BE

COORDINATED WITH COR FOUR WEEKS PRIOR TO MINIMIZE

MISSION IMPACT

KEY PLAN

N

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5

D

C

B

A

8'4' 16'

CUI

CUI

C U

I

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E D

A Y

T O

N

O H

IO

R E

P A

IR

/R

E N

O V

A T

E A

F M

C H

Q B

U

IL

D

IN

G

B

P

H A

S E

B262 PHASE

P

N O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J

B E

N S

O N

MD104A

A R

E A

D E

M O

L

IT

IO

N

P L

A N

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

N

B

R O

A D

W A

Y S

T

L O

U

IS

M

O

Q

H U

A N

G

A

C L

E A

R

K

G

IL

L

O C

T O

B E

R

W

Q R

R

X X

X X

B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION

B A

S E

M E

N T

A

R E

A

P

H A

S E

M E

C H

A N

IC

A

L

1/8" = 1'-0" A1

BASEMENT DEMOLITION PLAN - AREA 4

D04 DEMO RELIEF FAN AND…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .