This solicitation notice provides details for a renovation project at Wright-Patterson Air Force Base in Ohio. The U.S. Army Corps of Engineers Louisville District intends to issue a request for proposal for a fully designed renovation of over 60,000 square feet in the Air Force Materiel Command Headquarters Building. The project scope includes HVAC, plumbing, electrical, and telecommunications systems replacement along with interior finishes, windows, doors, and waterproofing. The contract duration is estimated at 1,095 calendar days with a construction magnitude between $100-250 million. The solicitation is anticipated for release on November 10, 2022 on SAM.gov and will utilize best value tradeoff source selection with evaluation of past performance and price/cost factors.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Controlled by: USACE-LRL-ED-MA CUI Category(ies):
LDC or Distribution Statement: N/A POC: Blake Gevedon Contracting Specialist william.b.gevedon@usace.army.mi 502.315.6791
Materials shall be submitted to potential offerors currently certified in the Joint Certification Program (JCP) only.
LS SEQUENCING KEY:
AREA OF WORK: ONCE SPRINKLERED THROUGHOUT, THE AREA OF
WORK DOES NOT REQUIRE RATED SEPARATION FROM OCCUPIED
AREA
1-HOUR FIRE RATED
AREA EXCEEDING COMMON PATH AND/OR TRAVEL DISTANCES.
REQUIRING ADDITIONAL EXIT SIGNAGE - REFER TO KEYED NOTE
2-HOUR FIRE RATED
POLYETHYLENE DUST BARRIER
DEMOLITION OF EXISTING BUILDING ELEMENTS AS DEPICTED IN SET
OCCUPIED AREA (FULLY SPRINKLED)
AREA OF FOCUS FOR LIFE SAFETY SEQUENCE W ORK
X
Y EXIT CAPACITY (MAXIMUM OCCUPANTS)
OCCUPANT LOAD
EXIT
EGRESS COMPONENT DESIGNATION
EXITING PROTECTED ENCLOSURE, MAINTAIN A FREE AND
UNOBSTRUCTED PATH (FULLY SPRINKLED)
BUILDING B10266 - NOT IN CONTRACT ENTRAPMENT AREA AND BUILDING B10262
(UNLESS OTHERWISE NOTED)
AREA OF PRIMARY WORK
DURING LS SEQUENCE 4 OF 5.
50' - 0" (MAXIMUM)
C1238
TRAVEL DISTANCE AND COMMON PATH LEGEND
0' * IMPROVED AT THE END OF PHASE 1
0' ** DEGRADED AT THE END OF PHASE 1
0' *** NON-COMPLIANT EXISTING CONDITION TO REMAIN
COMMON PATH (CP) OF
TRAVEL END POINT SYMBOL
TRAVEL PATH END POINT
TRAVEL PATH START POINT
AND WAY POINTS
TRAVEL DISTANCE (FEET) AND
COMMON PATH DISTANCE (FEET)
ASTERISK (REFER TO DESCRIPTION ABOVE)
TD 100'-0"
1. LIFE SAFETY SEQUENCING PLANS DEPICT PROTECTED EXIT ROUTE
THROUGHOUT AREA(S) OF WORK.
2. DOORS IN CONSTRUCTION BARRER MUST HAVE CLOSER AND LATCH OR BE IN-
FILLED WITH NEW PARTITION AS NOTED THAT MEETS OR EXCEEDS 1 HOUR FIRE
RATING.
3. SHADED AREA IS NOT UNDER CURRENT CONSTRUCTION PHASE UNLESS
OTHERWISE NOTED.
4. WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED WITH
COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.
5. EXITING PROTECTED ENCLOSURE MAY BE REMOVED AT SUCH TIME THAT THE
ENTIRE AREA IS FULLY PROTECTED WITH AN AUTOMATIC SPRINKLER SYSTEM, IN
ACCORDANCE WITH UFC 3-600-01.
6. COORDINATE CONSTRUCTION ACCESS DOORS FROM PROTECTIVE
ENCLOSURES IN ORDER TO ACCESS CONSTRUCTION ZONES IN PHASE 1.
GENERAL NOTES - LS SEQUENCINGKEYED NOTES - LS SEQUENCING#
ENTRAPMENT AREA AND BUILDING B10262
STAIR 6
STAIR 4
STAIR 2
STAIR 7
STAIR 8
TD 254' - 0"
EXIT 6.0B*
TD 256' - 0"
EXIT 6.0B*
TD 289' - 0"
EXIT 7.0**
TD 188' - 0"
EXIT 10.0B
TD 288' - 0"
EXIT 10.1B***
TD 301' - 0"
EXIT 10.3B***
TD 303' - 0"
EXIT 5.0B*
TD 337' - 0"
EXIT 5.1B*
TD 245' - 0"
EXIT 5.1B*
TD 383' - 0"
EXIT 9.0B*
CP 63' - 0"
EXIT 10.2B
CP 52' - 0"
EXIT 5.0B
CP 55' - 0"
EXIT 9.0B
TD 352' - 0"
EXIT 7.0***
STAIR 18
STAIR 17
STAIR 16
STAIR 3
STAIR 5
STAIR 1
TD 168' - 4"
EXIT 5.0B*
TD 169' - 0"
EXIT 10.2B
EXIT 10B
EXIT 6
EXIT 7
EXIT 9B
EXIT 5
AREA OF PRIMARY W ORK
DURING LS SEQUENCE 4 OF 5.
AREA OF PRIMARY W ORK
DURING LS SEQUENCE 4 OF 5.
NOTE:
PLAN REPRESENTS CONDITION DURING
CONSTRUCTION.
BUILDING B10262:
EXISTING FIRST FLOOR OCCUPANCY: 1,132
AVAILABLE EGRESS: 1,882
BUILDING B10266:
EXISTING FIRST FLOOR OCCUPANCY: 747
AVAILABLE EGRESS: 1,214
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
BE
N
SO
N
G100B.4
LI
FE
S
AF
ET
Y
SE
Q
U
EN
C
IN
G F
LO
O
R P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
H
IG
H
LA
N D
S
PL
AZ
A
D R
IV
E
SU
IT
E
ST
. L O
U
IS
, M O
R .M
ES
SE
L
C .M
EL
EN
D
EZ
J.
C
O R
SO
N
D
EC
EM
BE
R
B10262 PHASE 1 - CERTIFIED FINAL
FI
R
ST
F
LO
O
R
PH
AS
E
G
EN
E R
AL
N
0 32'16' 64'
G009
1/32" = 1'-0"A1 FIRST FLOOR OVERALL LIFE SAFETY PLAN - SEQUENCE 4 OF 5
035 1 HOUR FIRE RATED PROTECTIVE ENCLOSURE MUST BE IN PLACE UNTIL SUCH
TIME THAT THE ENTIRE BUILDING IS EQUIPPED WITH AN AUTOMATIC SPRINKLER,
IN ACCORDANCE WITH UFC 3-600-01 SECTION 9-7.4
052 PARTITION AND DOOR MUST BE CONSTRUCTED PRIOR TO COMMENCEMENT OF
SEQUENCE 4
055 POLYETHYLENE BARRIER AS REQUIRED TO CONTAIN DUST FROM
CONSTRUCTION ACTIVITIES
058 PROVIDE EXIT SIGNAGE DIRECTING OCCUPANTS TO EXIT 7.0. REVIEW VERBIAGE
AND LOCATIONS WITH COR IN ADVANCE
066 PARTITION TYPE '0M' - REFER TO A703 FOR ADDITIONAL INFORMATION. PT-1 AND
RB-1 FINISH ON BOTH SIDES
AM
EN
D
M
EN
T 0 0
J A
N
1 1
W
2Q R
R
_C U
I_ C
F_ Pl an s-
KEYED NOTES - LS SEQUENCING# LS SEQUENCING KEY:
AREA OF WORK: ONCE SPRINKLERED THROUGHOUT, THE AREA OF
WORK DOES NOT REQUIRE RATED SEPARATION FROM OCCUPIED
AREA
1-HOUR FIRE RATED
AREA EXCEEDING COMMON PATH AND/OR TRAVEL DISTANCES.
REQUIRING ADDITIONAL EXIT SIGNAGE - REFER TO KEYED NOTE
2-HOUR FIRE RATED
POLYETHYLENE DUST BARRIER
DEMOLITION OF EXISTING BUILDING ELEMENTS AS DEPICTED IN SET
OCCUPIED AREA (FULLY SPRINKLED)
AREA OF FOCUS FOR LIFE SAFETY SEQUENCE W ORK
X
Y EXIT CAPACITY (MAXIMUM OCCUPANTS)
OCCUPANT LOAD
EXIT
EGRESS COMPONENT DESIGNATION
EXITING PROTECTED ENCLOSURE, MAINTAIN A FREE AND
UNOBSTRUCTED PATH (FULLY SPRINKLED)
ENTRAPMENT AREA AND BUILDING B10262
STAIR 3
STAIR 5
STAIR 6
STAIR 4
STAIR 2
STAIR 1
203 203 203
066 043
066 043
203 050
A4 G101
AREA OF PRIMARY WORK
DURING LS SEQUENCE 2
OF 5.
AREA OF PRIMARY WORK
DURING LS SEQUENCE 2
OF 5.
203 056
1 HOUR FIRE RATED BARRIER MUST
SEPARATE NON SPRINKLERED AND
SPRINKLERED UNTIL SUCH TIME THAT THE
ENTIRE BUILDING IS EQUIPPED WITH AN
AUTOMATIC SPRINKLER SYSTEM, IN
ACCORDANCE WITH UFC 3-600-01 SECTION
9-7.4. OCCUPIED AREAS MUST EXIT THROUGH
A SPRINKLERED AREA. REFER TO G101 IF
BUILDING IS NOT FULLY PROTECTED.
POLYETHYLENE BARRIER MAY BE USED IN A
LIMITED CONSTRUCTION AREA FOR DEBRIS
AND DUST PROTECTION ONLY. PRIOR TO
IMPLEMENTATION LAYOUT MUST BE
APPROVED BY COR.
G100C.2A
B1
G100C.2A
B4
TD 230' - 0"
STAIR 2.0C
TD 187' - 0"
EXIT 13.0C
CP 29' - 0"
EXIT 13.0C
TD 194' - 0"
STAIR 1.0C
CP 75' - 0"
STAIR 1.0C
CP 113' - 0"
EXIT 10.0C***
TD 160' - 0"
EXIT 10.0C
TD 230' - 0"
STAIR 3.0C TD 212' - 0"
STAIR 3.0C
TD 238' - 0"
STAIR 5.0C
TD 242' - 0"
STAIR 5.0C
TD 192' - 0"
STAIR 3.0C
TD 253' - 0"
STAIR 6.0C***
CP 60' - 0"
STAIR 6.0C
TD 177' - 0"
STAIR 6.0C
CP 73' - 0"
STAIR 6.0C
TD 226' - 0"
STAIR 6.0C
CP 18' - 0"
STAIR 3.0C
TD 250' - 0"
STAIR 3.0C
CP 73' - 0"
STAIR 3.0C
TD 226' - 0"
STAIR 3.0C
TD 210' - 0"
STAIR 4.0C
CP 129' - 0"
STAIR 5.0C*
TD 178' - 0"
STAIR 5.0C
BUILDING B10266 - NOT IN CONTRACT
(UNLESS OTHERWISE NOTED)
TD 183' - 0"
STAIR 4.0C
50' - 0" (MAXIMUM)
50' - 0" (MAXIMUM)
EXIT 13C
STAIR 5
STAIR 6
STAIR 2
STAIR 3
STAIR 4
EXIT 10C
STAIR 1
TD 129' - 0"
STAIR 6.0C
TD 167' - 0"
STAIR 6.0C
C2225
C2226 068
TRAVEL DISTANCE AND COMMON PATH LEGEND
0' * IMPROVED AT THE END OF PHASE 1
0' ** DEGRADED AT THE END OF PHASE 1
0' *** NON-COMPLIANT EXISTING CONDITION TO REMAIN
COMMON PATH (CP) OF
TRAVEL END POINT SYMBOL
TRAVEL PATH END POINT
TRAVEL PATH START POINT
AND WAY POINTS
TRAVEL DISTANCE (FEET) AND
COMMON PATH DISTANCE (FEET)
ASTERISK (REFER TO DESCRIPTION ABOVE)
TD 100'-0"
1. LIFE SAFETY SEQUENCING PLANS DEPICT PROTECTED EXIT ROUTE
THROUGHOUT AREA(S) OF WORK.
2. DOORS IN CONSTRUCTION BARRER MUST HAVE CLOSER AND LATCH OR BE IN-
FILLED WITH NEW PARTITION AS NOTED THAT MEETS OR EXCEEDS 1 HOUR FIRE
RATING.
3. SHADED AREA IS NOT UNDER CURRENT CONSTRUCTION PHASE UNLESS
OTHERWISE NOTED.
4. WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED WITH
COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.
5. EXITING PROTECTED ENCLOSURE MAY BE REMOVED AT SUCH TIME THAT THE
ENTIRE AREA IS FULLY PROTECTED WITH AN AUTOMATIC SPRINKLER SYSTEM, IN
ACCORDANCE WITH UFC 3-600-01.
6. COORDINATE CONSTRUCTION ACCESS DOORS FROM PROTECTIVE
ENCLOSURES IN ORDER TO ACCESS CONSTRUCTION ZONES IN PHASE 1.
GENERAL NOTES - LS SEQUENCING
BUILDING B10262:
EXISTING SECOND FLOOR OCCUPANCY: 1,669
AVAILABLE EGRESS: 2,093
NOTE:
PLAN REPRESENTS CONDITION DURING
CONSTRUCTION.
NOTE:
NO WORK IS DONE IN LIFE SAFETY SEQUENCE 1
OF 5 ON THE SECOND FLOOR LEVEL.
BUILDING B10266:
EXISTING SECOND FLOOR OCCUPANCY: 747
AVAILABLE EGRESS: 864
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
G100C.2
LI
FE
S
AF
ET
Y
SE
Q
U
EN
C
IN
G F
LO
O
R P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
H
IG
H
LA
N D
S
PL
AZ
A
D R
IV
E
SU
IT
E
ST
. L O
U
IS
, M O
R . M
ES
SE
L
C . M
EL
EN
D
EZ
J.
C
O R
SO
N
D
EC
EM
BE
R
B10262 PHASE 1 - CERTIFIED FINAL
SE
C
O N
D F
LO
O
R
P H
AS
E
G
EN
E R
AL
N
0 32'16' 64'
G009
1/32" = 1'-0"A1 SECOND FLOOR OVERALL LIFE SAFETY PLAN - SEQUENCE 2 OF 5
043 DOOR WITH CLOSER AND LATCH
050 STAIR 8 AND EXTERIOR SAFE PASSAGE TO STREET MUST BE CONSTRUCTED IN
SEQUENCE 2 AND BE FULLY FUNCTIONAL TO AFMC STAFF AND RECEIVE A
CERTIFICATE OF ACCEPTANCE PRIOR TO SEQUENCE 3
056 STAIR 7 AND EXTERIOR SAFE PASSAGE TO STREET MUST BE CONSTRUCTED IN
SEQUENCE 2 AND BE FULLY FUNCTIONAL TO AFMC STAFF AND RECEIVE A
CERTIFICATE OF ACCEPTANCE PRIOR TO SEQUENCE 3
063 PROVIDE EXIT SIGNAGE DIRECTING OCCUPANTS TO STAIR 5. REVIEW VERBIAGE
AND LOCATIONS WITH COR IN ADVANCE
066 PARTITION TYPE '0M' - REFER TO A703 FOR ADDITIONAL INFORMATION. PT-1 AND
RB-1 FINISH ON BOTH SIDES
068 PARTITION AND DOOR MUST BE CONSTRUCTED PRIOR TO COMMENCEMENT OF
SEQUENCE 2
203 CONSTRUCTION BARRIER, TYPICAL. FOR ADDITIONAL INFORMATION REFER TO
AD100 SHEETS
AM
EN
D
M
EN
T 0 0
J A
N
W
2Q R
R
_C U
I_ C
F_ Pl an s-
B-000
BO
R
IN
G
L O
C
AT
IO
N
P
LA
N
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
J.
V
ER
ST
J.
V
ER
ST
S.
L
EE
P2
N O
SE
C
O N
D T
IT
LE
J.
B
EN
SO
N
C
IV
IL
C U
I
CUI
CUI
D
EC
EM
BE
R
W
R
IG
H T-
PA
TT
ER
SO
N A
IR
F
O R
C E
BA
SE
D
AY
TO
N
, O H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE 1
B10262 PHASE 1 - CERTIFIED FINAL
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
H
IG
H
LA
N D
S
PL
AZ
A
D R
IV
E
SU
IT
E
ST
. L O
U
IS
, M O
PH
AS
E
A. GEOTECHNICAL DATA SHOWN ON THIS SHEET IS
FOR REFERENCE TO THE SOIL BORING AND
SHEAR-WAVE INFORMATION ON SUBSEQUENT
SHEETS.
GENERAL NOTES
B10262
B10266
B10277
H ROAD
N R
O
AD
A R
O
AD
T ROAD
A STREET
B10271
C
RO
AD
B10264
B10262
B10286
BORING LOCATION TABLE
BORE #
Elevation
835.64
835.30
835.57
834.64
833.54
834.20
835.71
836.15
836.22
832.37
834.55
835.72
835.63
835.63
834.88
834.98
836.38
833.42
Northing
658850.9499
658840.2117
Easting
1533665.1650
1533850.8170
BORE #10
SCALE: 1" = 50'
100'0 50'
N
BORE #11
BORE #18
BORE #12
BORE #13
BORE #14
BORE #9
BORE #8
BORE #4
BORE #16
BORE #5
BORE #6
BORE #15
BORE #3
BORE #2
BORE #17
BORE #7
BORE #1
658822.2143 1534100.2340
658850.0843 1534202.9940
658941.1044 1534240.2009
659037.6743 1534427.4627
658763.9924 1533649.5500
658653.6752 1534410.8610
658517.6981 1534398.5740
658427.0744 1533616.5905
658411.4338 1533785.4900
658423.1370 1533995.2500
658407.0740 1534147.3720
658444.6125 1534349.5100
659065.0296 1534429.4560
658850.8232 1534174.3690
658771.7088 1533868.7590
658374.8718 1533833.9430
SHEAR WAVE
PROFILE #1
SHEAR WAVE
PROFILE #2
SHEAR WAVE
PROFILE #3
LEGEND
GEOTECHNICAL BORING LOCATION
AM
EN
D
M
EN
T
W
2Q R
R
_C U
I_ C
F_ Pl an s-
1. ALL MATERIALS AND CONSTRUCTION SHALL CONFORM TO AFCEC SPECIFICATIONS AND PLANS EXCEPT
AS NOTED HEREIN AND APPROVED BY THE CONTRACTING OFFICER (C.O.).
2. IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT ALL PUBLIC AND PRIVATE UTILITIES IN THE CONSTRUCTION OF THIS PROJECT. ALL MANHOLES, CLEANOUTS, VALVE BOXES, FIRE HYDRANTS ETC. MUST BE ADJUSTED TO PROPER LINE AND GRADE BY THE CONTRACTOR PRIOR TO AND AFTER
PLACING OF PERMANENT PAVING AND/OR ESTABLISHING FINISHED GRADE IN EARTHEN AREAS.
UTILITIES MUST BE MAINTAINED TO PROPER LINE AND GRADE DURING CONSTRUCTION OF THE PAVING
FOR THIS PROJECT.
3. CONTRACTOR TO FIELD VERIFY ELEVATION OF EXISTING PAVEMENT AND LANDSCAPE AREAS PRIOR TO
CONSTRUCTION AND NOTIFY ENGINEER AND C.O. OF DISCREPANCIES IN FIELD CONDITIONS.
4. PRIOR TO PLACING ANY FILL MATERIAL, ALL EXISTING SURFACES, VEGETATION, LOOSE FILL AND DEBRIS
SHOULD BE REMOVED TO A MINIMUM DEPTH OF 4". ALL EXPOSED SURFACES SHOULD THEN BE
SCARIFIED, WATERED AS REQUIRED AND RE-COMPACTED ACCORDING TO EARTHWORK
SPECIFICATIONS.
5. ALL GRADES AND CONTOURS SHOWN ARE TOP OF FINISH SURFACE ELEVATIONS, UNLESS OTHERWISE
NOTED.
6. POSITIVE DRAINAGE SHALL BE MAINTAINED ON ALL SURFACES WITHIN THE SCOPE OF THE PROJECT.
DRAINAGE SHALL BE DIRECTED AWAY FROM ALL BUILDING FOUNDATIONS. CONTRACTOR TO TAKE PRECAUTIONS NOT TO ALLOW ANY PONDING OF WATER. CONTRACTOR SHALL IMMEDIATELY NOTIFY
ENGINEER OF ANY AREAS WHERE PONDING BECOMES AN ISSUE.
7. CONTRACTOR TO OBTAIN GRADES WITHIN ±FOUR-HUNDREDTHS (0.04) FOOT.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING TO ITS ORIGINAL OR BETTER CONDITIONS ANY
DAMAGE DONE TO EXISTING BUILDINGS, UTILITIES, FENCES, PAVEMENTS, CURBS OR DRIVEWAYS.
9. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE C.O. OF ANY QUESTIONS THAT MAY ARISE CONCERNING
THE INTENT, PLACEMENT, OR LIMITS OF DIMENSIONS OR GRADES NECESSARY FOR CONSTRUCTION OF
THE PROJECT.
10. CONTRACTOR SHALL GRADE AREAS ADJACENT TO THE EXISTING CHANNELS TO MATCH EXISTING SITE
GRADES BASED ON MAXIMUM SLOPES OF 4:1 UNLESS OTHERWISE NOTED.
11. ALL EXCAVATION IS UNCLASSIFIED.
12. SITE AREAS REQUIRING FILL PLACEMENT SHALL BE SCARIFIED AND MOISTURE ACTIVATED TO WITHIN
±3% OF OPTIMUM MOISTURE CONTENT. COMPACT SUBGRADE TO 95% MAXIMUM DRY DENSITY.
13. EXISTING AND PROPOSED GRADE CONTOURS ARE SHOWN AT ONE FOOT (1.0 FT) INTERVALS.
14. ACCESSIBLE ROUTES AND PATHWAYS SHALL CONFORM TO ADA STANDARDS FOR ACCESSIBLE DESIGN, LATEST EDITION. PATHWAY/SIDEWALK SHALL MEET MAXIMUM 2% CROSS SLOPE AND MAXIMUM 5%
RUNNING SLOPE REQUIREMENTS.
15. ALL DISTURBED AREAS SHALL BE HYDRO-MULCHED AND WATERED FOR TWO WEEKS UNTIL GRASS IS
ESTABLISHED.
16. ALL SURPLUS SOIL FROM EXCAVATIONS SHALL BE DISPOSED OF OFF SITE.
17. SILT FENCING AND/OR TEMPORARY BERMS SHALL BE INSTALLED PRIOR TO START OF CONSTRUCTION.
18. TEMPORARY SWALES AND DE-SILTING BASINS WILL BE PLACED WHERE NECESSARY IN ORDER TO
CONVEY STORMWATER RUN-OFF.
19. BECAUSE THIS PROJECT LIES WITHIN THE HUFFMAN DAM RETARDING BASIN; A STORAGE
COMPENSATION AGREEMENT MUST BE PREPARED BY THE CONTRACTOR FOR APPROVAL BY WPAFB
AND THE MIAMI CONSERVANCY DISTRICT (MCD) FOR ALL SOILS IMPORTED, EXPORTED OR STOCKPILED.
SEE EARTHWORK SPECIFICATION 31 00 00.00 06 AND THE STORAGE COMPENSATION AGREEMENT
ATTACHMENT.
1. CONTRACTOR TO INSTALL TEMPORARY TAB STRIPING FOR 30 CALENDAR DAYS TO ALLOW FOR
PROPER ASPHALT CURE TIME.
2. TEMPORARY TAB STRIPING SHOULD BE PLACED NO SOONER THAN 3 CALENDAR DAYS AFTER THE
PLACEMENT OF ASPHALT.
3. MAINTAIN ALIGNMENT TRAFFIC CONTROL DEVICES AND OPERATION UNTIL MARKINGS ARE
INSTALLED.
4. ALL MARKING MUST BE VISIBLE FROM A DISTANCE OF AT LEAST 300 FEET IN DAYLIGHT CONDITIONS
AND FROM A DISTANCE OF AT LEAST 160 FEET IN NIGHTTIME CONDITIONS, ILLUMINATED BY
LOW-BEAM HEADLIGHT.
5. CONTRACTOR SHALL REFERENCE SDDCTEA PAMPHLET 55-17 FOR PAVEMENT MARKINGS AND UFGS
FOR COMPLETE REGULATIONS.
Base Civil Engineering POC for Anti-Terrorism/Force Protection (AT/FP):
Mr. Mike Wethington, 88 CEG/CENPD, 656—3579
Base Civil Engineering/88 CEG:
Mike Baumann, Senior Leader, Oversight, 937-257-6208, michael.bauman@wpafb.af.mil Robert Blevins, project Execution Section Chief, Engineering Division, 937-257-2764, robert.blevins@us.af.mil Randy Brown (DCIC) (primary) Scott Michaelson (alternate)
Architectural Review Committee (ARC):
Mr. Amir Mott, 88 CEG/CENMP, 937-257-6214, amir.mott@us.af.mil MICHAEL SAPP, 88 CEG/CEN, 937-904-1235, michael.sapp.8@us.af.mil Chris Pleiman, 88 CEG/CEN, 937-904-1164, christopher.pleiman.1@us.af.mil
Base Communications:
Ms. Kathy Fletcher, 88 CG/SCXP, 255-0681 Chris Dunham, Comm PM Supervisor, 937-257-2548, christopher.dunham.4@us.af.mil
Base Community Planners:
Mrs. Laura Wade, 88 CEG/CENPL, 904-3519 Mrs. JoLynn Anderson, 88 CEG/CENPL, 656-3382
Base Energy Management:
Mr. Michael Tibbs, 88 CEG/CENPE, 656-3394
Base Facility Standard Editor:
Ms. Christine Yankel, 88 CEG/CENMP, 656-3385
Base Safety:
Stew Balczone
Comprehensive Interior Design:
Ms. Sharion Harvin, 88 CEG/CENMP, 656-3390
Electric Utility Privatization:
Mr. Darryl Thomas, 88 CES/CEOER, 904-2201
Environmental Management:
Dr. Christina Powell, 88 CEG/CEIEA, 257-5527
Fire Prevention:
Mr. Jeffery Kitzmiller, 788 CES/CEXFP, 904-3158
Fire Protection Specialist – Alarm/Detection Systems:
Mr. Gary Stevens, 88 CEG/CENMP, 257-1509 Mr. Dan Sharp, 88 CEG/CENMP, 656-3593
Fire Protection Specialist – Sprinkler Systems:
Mr. Steve Grimes, 88 CEG/CENMP, 656-3562
Historic Preservation:
Mr. Paul Woodruff, 88 CEG/CEIEA, 257-1374
Industrial Control Systems (ICS):
Mr. David Vaughn, 88 CES/CEOIC, 904-2431 (primary) Mr. Michael Labar, 88 CES/CEOIC, 656 -0360 (Alternate)
Information Protection – Physical Security (Classified Facility Construction):
Mr. William Speakman, 88 ABW/IPI, 255-4756 Mr. Thomas Pavlick, 88 ABW/IPI, 255-4890
Mechanical HVAC & Plumbing Engineer:
Keith Bishop, Plumbing, 937-257-1928, keith.bishop.6@us.af.mil Kevin Haas, 937-257-1928, kevin.haas@us.af.mil
Mechanical Infrastructure Engineer:
Mr. Jesse Poorman, 88 CES/CEOER, 656-3028
Pavement/Airfield Pavement Engineer:
Mr.Jari Ulmer, 88 CEG/CENMP, 257-8941
Record Drawings:
Mr. Michael Louis, 88 CEG/CENME, 656-3410
Structural Engineer:
Mr. Victor Erewele, 88 CEG/CENMP, 656-3455
Traffic Engineer:
Mr. Brady Klein, 88 CEG/CENMP, 937-904-0199
Water/Sanitary/Waste Treatment Engineer:
Mr. Joe Piechota, 88 CEG/CENMP, 904-1183
USACE Louisville District Kevin Jefferson, Chief Construction, 502-315-6115, kevin.r.jefferson@usace.army.mil Greg Moore, Project Manager, 502-315-6902 , 502-381-6061, gregory.f.moore@usace.army.mil Linda Myrphy, Louisville DDE, 502-315-6104, Linda.R.Murphy@usace.army.mil Michael Hutchens, Contracting Lead, 502-315-6180, michael.d.hutchens@usace.army.mil John Hearn, Lead Construction Rep, 937-656-6463, john.p.hearn@usace.army.mil Kelly Hecht, Project Engineer, 937-656-9127, kelly.e.hecht@usace.army.mil
AFCEC
Thomas Hodges Design & Construction Branch Chief, 210-395-8520, thomas.hodges@us.af.mil Steve Frahm, Program Manager,210-395-8273, stephen.frahm@us.af.mil
HQ AFMC
Robert Gingell. PMO Chief, 937-503-3183, robert.gingell@us.af.mil
AES OHIO
Mark Edsall Mark.Edsall@AES.com
AMERICAN WATER
Cory Kinnison, 937-371-9648, cory.kinnison@amwater.COM Randy Fries, 937-623-9786, randolph.fries@amwater.com
VECTREN GAS
Brenton Balsbaugh, 765-939-4608, brenton.balsbaugh@centerpointenergy.com Robert A. Robinson, 937-271-7125, robertarobinson@centerpointenergy.com
1. NO ASBESTOS-CONTAINING MATERIAL SHALL BE INSTALLED DURING THIS PROJECT.
2. SOIL DISTURBANCE DURING THIS PROJECT, INCLUDING EQUIPMENT STAGING AREAS, WILL REQUIRE EROSION CONTROL
MEASURES. FOR PROJECTS THAT DISTURB LESS THAN AN ACRE OF SOIL, AN EROSION CONTROL PLAN IS REQUIRED PRIOR TO SOIL DISTURBANCE. FOR PROJECTS THAT DISTURB MORE THAN AN ACRE, A NOTICE OF INTENT (NOI) MUST BE APPROVED BY THE OHIO EPA PRIOR TO ANY SOIL BEING DISTURBED AS WELL AS A STORM WATER POLLUTION PREVENTION PLAN (SWPPP) APPROVED BY 88 CEG/CEIEA. PLEASE CONTACT THE 88 CEG/CEIEA WATR PM MIKE VAUGHN, (937- 257-8028 OR
MICHAEL.VAUGHN.3@US.AF.MIL ) FOR ADDITIONAL INFORMATION.
3. THE GENERATION OF FUGITIVE EMISSIONS MUST BE KEPT TO A MINIMUM USING APPROVED DUST SUPPRESSING METHODS SUCH AS WATER SPRAYS ON AREAS OF HIGH DUST GENERATION. FOR ADDITIONAL INFORMATION PLEASE CONTACT THE 88 CEG/CEIEA AIR PM MR. CHET POWERS. CHET CAN BE REACHED AT 937-257-3349 OR BY EMAIL AT CHET.POWERS@US.AF.MIL
4. REMOVE AND DISPOSE OF ANY ASBESTOS CONTAINING MATERIAL IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 35 43.
5. ALL WINDOW AND DOOR FRAME CAULKING AND GLAZING WILL BE TREATED AS CONTAINING ASBESTOS UNLESS TESTING PROVES IT
TO BE ASBESTOS FREE.
6. DEMOLITION OF LOAD-BEARING WALLS OR STRUCTURALCOMPONENTS REQUIRE NOTIFICATION OF DEMOLITION AND RENOVATION TO THE REGIONAL AIR POLLUTION AND CONTROL AGENCY (RAPCA) A MINIMUM OF 10 WORK DAYS PRIOR TO
BEGINNING CONSTRUCTION.
7. RECOVER AND RECLAIM ANY REFRIGERANT IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 02 41 00.
8. IF ANY REFRIGERANT-CONTAINING EQUIPMENT SCHEDULED FOR NEW INSTALLATION, INCLUDING WATER COOLERS, THEY
MUST UTILIZE AN HFC REFRIGERANT. CFC AND HCFC REFRIGERANTS ARE NOT AUTHORIZED FOR NEW EQUIPMENT INSTALLATIONS. FOR ADDITIONAL INFORMATION PLEASE CONTACT THE 88 CEG/CEIEA AIR PM CHET POWERS. CHET CAN BE
REACHED AT 937-257-3349 OR BY EMAIL AT CHET.POWERS@US.AF.MIL.
9. ALL HAZARDOUS MATERIALS MUST BE PROPERLY MANAGED, LABELED AND STORED. ANY HAZARDOUS WASTE GENERATED FROM THIS CONSTRUCTION ACTIVITY MUST BE PROPERLY CHARACTERIZED, LABELED AND MANAGED BY TRAINED EMPLOYEE OF THE CONTRACTOR WITH KNOWLEDGE OF THE ACTIVITY / PROCESS WHERE THE WASTE WAS GENERATED.
ALL HAZARDOUS WASTE WILL BE TURNED OVER TO THE GOV'T FOR DISPOSAL. IN ADDITION PROPER COORDINATION IS NEEDED WITH 88 CEG/CEIEC. QUESTIONS CONCERNING THE REQUIREMENTS FOR STORAGE AND DISPOSAL OF ANY
HAZARDOUS MATERIALS CAN BE ADDRESSED BY THE 88 CEG/CEIEC HAZARDOUS MATERIALS PM,
KAREN.BEASON@US.AF.MIL OR BY PHONE AT 937-257-5899 OR 88 CEG/CEIEC HAZARDOUS WASTE PM, EMILY EDREI (937-257-
0023 OR EMILY.ERDEI@US.AF.MIL).
10. ANY LEAD CONTAINING PAINT CONTROL MEASURES SHALL BE PERFORMED IN ACCORDANCE WITH WPAFB SPECIFICATION
SECTION 01 35 43.
11. ALL METAL AND WIRING SHALL BE RECYCLED AT THE WPAFB BASE RECYCLING CENTER. THE WPAFB RECYCLING CENTER IS AVAILABLE FOR CONTRACTOR USE TO REDUCE WASTE DISPOSAL. ALL RECYCLABLE METAL IS TO BE RECYCLED THROUGH THE BASE RECYCLING CENTER. ALL RECYCLING MUST BE ACCOMPLISHED IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 35 43. CONTACT WPAFB RECYCLING PROGRAM MANAGER AT 937-257-5060 TO CONFIRM WHAT MATERIALS ARE RECYCLABLE AND TO COORDINATE TURN-IN. THE CONTRACTOR SHALL SUBMIT A QUARTERLY SUMMARY REPORT TO THE GOVERNMENT CONTRACT REPRESENTATIVE IAW WPAFB SPECIFICATION SECTION 01 35 43 STATING (1) THE COST TO RECYCLE AND THE TONNAGE OF CONSTRUCTION AND DEMOLITION MATERIALS RECYCLED, (2) THE COST TO DIVERT/REUSE THE TONNAGE OF CONSTRUCTION AND DEMOLITION MATERIALS DIVERTED/REUSE, (3) THE COST TO MULCH AND THE TONNAGE AND COST OF CONSTRUCTION AND DEMOLITION MATERIALS MULCHED, (4) THE COST FOR WASTE-TO-ENERGY AND THE TONNAGE OF CONSTRUCTION AND DEMOLITION MATERIALS CONVERTED FROM WASTE-TO-ENERGY, (5) THE COST TO LANDFILL AND THE TONNAGE OF CONSTRUCTION AND DEMOLITION MATERIALS LAND-FILLED, (6) THE COST TO INCINERATE AND THE TONNAGE OF CONSTRUCTION AND DEMOLITION MATERIALS INCINERATED, AND (7) EXPLANATION OF THE DIVERSION RATE IF LESS THAN 60%. THE QUARTERLY SUMMARY REPORTS SHALL BE RECEIVED ON APRIL 7, JULY 7, OCTOBER 7, AND JANUARY 7 COVERING THE THREE MONTHS PRIOR. THE QUARTERLY SUMMARY REPORTS SHALL BE ON THE WPAFB DIVERSION FORM. FOR ADDITIONAL INFORMATION CONTACT THE RECYCLING PM, DAVE DALTON, AT
937-257-5060 OR DAVID.DALTON.2@US.AF.MIL.
12. TURN-IN ALL MERCURY CONTAINING DEVICES, SWITCHES AND THERMOSTATS TO 88 CEG/CEIE IN ACCORDANCE WITH
WPAFB SPECIFICATION SECTION 01 35 43 FOR RECYCLING.
13. TURN-IN ALL PCB CONTAINING LIGHT BALLAST TO 88 CEG/CEIE IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 35 43.
14. 30 DAYS PRIOR TO START OF WORK, THE CONTRACTOR SHALL TAKE A REPRESENTATIVE SAMPLE OF THE HVAC SYSTEM WATER TO DETERMINE WHETHER IT CAN BE DRAINED DIRECTLY INTO THE SANITARY SEWER. ANALYZE THE WATER TO DETERMINE THE TOTAL LEVEL OF EACH OF THE FOLLOWING: CADMIUM, CHROMIUM, COPPER, CYANIDE, LEAD, MERCURY, MOLYBDENUM, NICKEL, SILVER, ZINC, SULFIDE, OIL AND GREASE. THE LAB PERFORMING THE ANALYSES MUST BE CERTIFIED BY OHIO EPA TO ANALYZE FOR THESE PARAMETERS. PROVIDE A COPY OF THE LAB'S REPORT TO THE CONTRACTING OFFICER, WHO WILL IN TURN FORWARD IT TO 88 CEG/CEIEA FOR A DETERMINATION ON THE WASTEWATER
DISPOSAL METHOD.
15. COORDINATE DISPOSITION OF EXCESS RADIOACTIVE COMMODITIES, E.G. IONIZATION TYPE SMOKE DETECTORS, RADIOLUMINESCENT EMERGENCY EXIT SIGNS, OR ANY OTHER RADIOACTIVE COMMODITY AND/OR RADIOACTIVE
CONTAMINANT THROUGH THE INSTALLATION RADIATION SAFETY OFFICER, 88 AMDS/SGPB.
16. IF ANY SANITARY SEWER MAINS ARE BEING EXTENDED, UPSIZED OR NEW MAINS ARE BEING INSTALLED A PERMIT TO INSTALL (PTI) MAY BE REQUIRED FROM THE OHIO EPA PRIOR TO BEGINNING MAIN INSTALLATION. THE CONSTRUCTION CONTRACTOR SHALL PREPARE AND SUBMIT A DRAFT PTI PACKAGE TO THE CONTRACTING OFFICER'S REPRESENTATIVE, INCLUDING A CHECK FOR ANY APPLICABLE OHIO EPA FEES, FOR REVIEW AND PROCESSING BY ENVIRONMENTAL MANAGEMENT, 88 CEG/CEIEA. ENVIRONMENTAL MANAGEMENT SHALL ENDORSE THE PACKAGE AS THE UTILITY OWNER AND SHALL SUBMIT IT TO OHIO EPA. PLEASE CONTACT THE 88 CEG/CEIEA WATER PM, MIKE VAUGHN, (937-257-8028 OR
MICHAEL.VAUGHN.3@US.AF.MIL).
17. NO TREE CUTTING BETWEEN 01 APRIL AND 30 SEPTEMBER W/ OUT THE WRITTEN APPROVAL FROM THE 88 CEG/CEIEA NATURAL RESOURCE PROGRAM MANAGER (NR PM). SUBMIT A LIST OF THE TREES TO BE REMOVED AND REPLACED. THREE TREES SHALL BE REPLACED FOR EVERY ONE TREE REMOVED. THE GENERAL 10-20-30 DIVERSITY RULE SHALL BE FOLLOWED WHEN PLANTING TREES. ONLY PLANTS/TREES ON THE APPROVED PLANTING LIST CAN BE PLANTED AND MUST BE OHIO NATIVES. CONTACT NATURAL RESOURCE PM DARRYN WARNER BY EMAIL AT DARRYN.WARNER@US.AF.MIL OR BY PHONE AT 937-257-4857 FOR ADDITIONAL INFORMATION. THE NUMBER OF TREE PLANTINGS SHOWN ON SHEET CS102 SHOULD BE SUBTRACTED FROM THE TOTAL NUMBER OF TREES REQUIRED TO BE PLANTED. A LIST OF TREES WITH THEIR LOCATION TO BE PLANTED SHOULD BE PROVIDED TO THE NATURAL RESOURCES PROGRAM MANAGER FOR APPROVAL.
ENVIRONMENTAL NOTES GRADING NOTES PROJECT CONTACTS
STRIPING NOTES
C
IV
IL
N
O
TE
S
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
J.
V
ER
ST
J.
V
ER
ST
S.
L
EE
P2
N O
SE
C
O N
D T
IT
LE
J.
B
EN
SO
N
C
IV
IL
C U
I
CUI
CUI
D
EC
EM
BE
R
W
R
IG
H T-
PA
TT
ER
SO
N A
IR
F
O R
C E
BA
SE
D
AY
TO
N
, O H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE 1
B10262 PHASE 1 - CERTIFIED FINAL
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
H
IG
H
LA
N D
S
PL
AZ
A
D R
IV
E
SU
IT
E
ST
. L O
U
IS
, M O
PH
AS
E
C-001
1 1
AM
EN
D
M
EN
T
AM
EN
D M
EN
T
AM
EN
D
M
EN
T
W
2Q R
R
_C U
I_ C
F_ Pl an s-
TOILET ACCESSORIES NOTES
1. EVERY ACCESSORY SHOWN MAY NOT BE USED ON THIS PROJECT. REFER TO
PLANS AND INTERIOR ELEVATIONS.
2. COORDINATE AND VERIFY THE LOCATIONS OF ACCESSORIES. BRING
CONFLICTING MOUNTING LOCATIONS TO THE ATTENTION OF THE COR PRIOR
TO INSTALLATION.
3. CONFIRM DIMENSIONS WITH FIXTURE AND ACCESSORY MANUFACTURER,
LATEST EDITION OF ABA.
4. REFERENCES TO ABA ARE MADE TO THE ARCHITECTURAL AND
TRANSPORTATION BARRIERS COMPLIANCE BOARD.
5. GRAB BARS MUST BE DESIGNED AND INSTALLED TO EXCEED THE BENDING
AND SHEAR STRESS STANDARDS FOR GRAB BARS AND ATTACHMENTS FOR
ABA GUIDELINES AND THE CODE.
6. MOUNTING HEIGHTS INDICATED ARE FOR ADULT TOILETS.
7. FOR GRAB BARS AT STUD PARTITIONS, REFER TO B1/A573.
8. FOR GRAB BARS AT TOILET PARTITIONS, REFER TO A1/A573.
9. FOR TOILET PARTITION FLOOR ANCHORAGE, REFER TO B2/A573.
10. ITEM NUMBERS REFER TO BOBRICK FOR REFERENCE ONLY UNLESS
OTHERWISE NOTED. REFER TO SPECIFICATION FOR APPROVED EQUALS.
11. PROVIDE INTEGRAL STROBE AND HORN AT EACH EMERGENCY
SHOWER/EYEWASH. REFER TO PLUMBING AND ELECTRICAL.
12. WHETHER INDICATED ON ELEVATIONS OR NOT, WATER CLOSETS MUST HAVE
AN ADJACENT TOILET TISSUE DISPENSER. FEMALE TOILET STALLS MUST HAVE
A SANITARY NAPKIN DISPOSAL.
13. TOILET PAPER DISPENSER MUST BE 7" MINIMUM AND 9" MAXIMUM IN FRONT OF
THE WATER CLOSET.
14. INSTALL WOOD BLOCKING IN PARTITIONS TO SUPPORT TOILET ACCESSORIES.
REFER TO C2/A707.
15. FOR ADDITIONAL MOUNTING HEIGHT INFORMATION REFER TO A003 AND G111.
(WC) WATER CLOSET
(WC-A) WATER CLOSET
ACCESSIBLE
(GB1) GRAB BAR 36"
(WC) WATER CLOSET
(WC-A) WATER CLOSET
ACCESSIBLE
(GB2) GRAB BAR 42"
(GB3) GRAB BAR 18" VERTICAL
TOP OF
SEAT TOP OF SEAT
2'
1' - 6"
3' - 0" 6"
1' -5
1'
3" 2'
1' - 0" 3' - 6" 1'
6"
3' - 4"
(TTD) TOILET TISSUE
DISPENSER ACCESSIBLE
KIMBERLY-CLARK
#09551 CORED JRT JUMBO COMBO
TISSUE DISPENSER
(GFCI)
1' -5
1'
3"
(U) URINAL
(U-A) URINAL
ACCESSIBLE
(TS) TOILET SEAT
COVER DISPENSER
ACCESSIBLE
(L) LAVATORY
(L-A) LAVATORY
ACCESSIBLE
PROVIDE
PROTECTION
AROUND PIPES
(L-A)
TOP OF RIM
C
EN
TE
R
LI
N
E O
F O
PE
N
IN
G
4'
0"
1' -5
U
-A
2'
0"
3' -8
U
-A
4'
3"
2' -1
0" M
AX
(L
-A
2'
7"
2' -5
" M
IN
(L -A
(US) UTILITY SHELF WITH
MOP/BROOM HOLDERS
AB
O
VE
M
O P
SI
N
K
5'
0"
2' - 6"
(SN) SANITARY NAPKIN
DISPOSAL
(SN-A) SANITARY NAPKIN
DISPOSAL ACCESSIBLE
(T) PAPER TOWEL
DISPENSER
(T-A) PAPER TOWEL
(S) WALL MOUNTED
SOAP DISPENSER
3'
8"
(TBS) TOW EL
BAR/SHELF
(TBS-A) TOWEL
BAR/SHELF
(EWC) ELECTRIC
WATER COOLER
NOTE: BOTTLE
FILLER MUST BE
ABA COMPLIANT
4' -0
TB
S- A)
4'
0"
(M) MIRROR
CENTER
MIRROR ON
LAVATORY
NOTE:
DIMENSION IS
TO BOTTOM OF
REFLECTIVE
SURFACE
M
AX
IM
U
M
3'
4"
3'
2"
2'
1"
SN
-A
2'
6"
2'
6"
1/ 2"
M
IN
IM
U
M GRAB BAR -
SHOWN DASHED
3'
0" M
AX
3'
6"
6'
0" T
O S
H O
W
ER
C
EN
TE
R
LI
N
E O
F
SH
O
W
ER
H
EA
D T
YP
IC
AL
M
EN
S
(SF) SHOWER FIXTURE
6’ -6
”T O
S H
O W
ER
C
EN
TE
R
LI
N E
O F
SH
O
W
ER
H
EA
D T
YP
IC
AL
W
O M
EN
S
NOTES:
1. FOR GRAB BAR ANCHORAGE DETAILS REFER TO A1 AND B1/ A573,
TYPICAL.
2. TOP OF HORIZONTALLY INSTALLED GRAB BARS MUST NOT
EXCEED 36" AFF.
(W C
-A
(W C
-A
NOTES:
1. FLOOR MOUNTED WATER CLOSETS INDICATED. DIMENSIONAL INFORMATION IS RELATIVE TO PARTITION-MOUNTED WATER CLOSETS AS WELL.
2. ACCESSORIES INDICATED MAY NOT BE USED ON THIS PROJECT.
(SCR) SHOW ER CURTAIN ROD
AND
(SC) SHOWER CURTAIN
6'
8"
REFER TO PLAN
2'
1'
6"
3' - 0" 1' - 6" 1'
6"
4'
0" M
AX
HOSE
5’ - 0” LONG
(SS-H) SHOWER STALL
ACCESSIBLE
(FSS) PHENOLIC
FOLDING SEAT
(GB4) STAINLESS STEEL
GRAB BAR 24” x 36”
AND
(GB3) GRAB BAR 18”
VERTICAL
TO
C
O N
TR
O
L
PO
IN
T
C
EN
TE
R
LI
N
E
(S/EWS) SHOW ER/EYE
WASH STATION
(FM) FULL LENGTH
MIRROR
5'
0" 1'
2"
4' -0
C
H -A
5'
6"
4'
0" (R
H -A
5'
6"
(CH) COAT HOOK
(CH-A) COAT HOOK
ACCESSIBLE
(RH) ROBE HOOK
(RH-A) ROBE HOOK
ACCESSIBLE
2' - 0"
(EWS) EYE
WASH STATION
3'
6"
C3 A574
7" TO 9"
1/
2" M
IN
IM
U M
3' -4
T-
A)
4'
0"
NOTE:
AT RESTROOMS WITH ONE PAPER
TOWEL DISPENSER INSTALL AT (T-A)
HEIGHT. REFER TO ELEVATIONS AND
ACCESSIBILITY PLANS
(MR-2) LED VANITY MIRROR
ELECTRIC MIRROR
3'
1" 3'
0"
(MR-1) LED VANITY MIRROR
ELECTRIC MIRROR
3'
1" 3'
0"
2' - 0" 4' - 0"
3'
4" M
AX
IM
U M
REFLECTIVE
SURFACE
REFLECTIVE
SURFACE
3'
4" M
AX
IM
U M
PANIC BAR
(EYEWASH)
3'
/2
PANIC BAR
(SHOWER)
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
A002
TO
IL
ET
A
C C
ES
SO
R
IE
S/ M
O U
N
TI
N G
H
EI
G H
TS
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
H
IG
H
LA
N D
S
PL
AZ
A
D R
IV
E
SU
IT
E
ST
. L O
U
IS
, M O
R . M
ES
SE
L
P.
M
C
EL
V
EN
EY
J.
C
O R
SO
N
D
EC
EM
BE
R
B10262 PHASE 1 - CERTIFIED FINAL
PH
AS
E
AR
C
H
IT
EC
TU
R
AL
1/2" = 1'-0"
TOILET ACCESSORY MOUNTING HEIGHTSA1
A001
AM
EN
D
M
EN
T 0 0
J A
N
W
2Q R
R
_C U
I_ C
F_ Pl an s-
G
F
E
D
C
B
A
1 2 3 4 51-J
1-17
1-16
1-15
1-14
1-13.5
1-13
1-12
M
AT
C H
LI
N
E
A1
AD
7A
MATCHLINE
A1 AD111A
FOR PROTOCOL OF STAIR 2 -
REFER TO LS002 AND
ENLARGED STAIR PLAN
INSTALL NEW DOORS WITH HARDWARE
TO SECURE BUILDING PRIOR TO
REMOVAL OF VEHICULAR GATES -
REFER TO A110A
NOTE:
PROVIDE MINIMUM 8' - 0" W IDE CLEAR
EGRESS FOR OCCUPANTS IN BASEMENTS OF
BUILDINGS B10262 AND B10266 TO AND UP
RAMP AND CLEAR OF BUILDINGS FOR
DURATION OF PHASE 1
± 11' - 11 1/4"
ROUGH OPENING
5' - 7" ± 20' - 2 1/4"
192192
8'
3"
192192
CB
CB
CB
CB
CB
CB
CB
CB
4' - 5"
14' - 1 3/4"
1'
1/
2"
/4
458458
446446446
CB
CB
CB
1' - 4" 7' - 5"
CB
C
C0281
C0296
151151151151151151151151151
151151
9" 8 1/2"
160160160
446 325
KEYED NOTES - DEMOLITION#
DEMOLITION LEGEND
REMOVE WALL / PARTITION
REMOVE DOOR
REMOVE DOORS
CONSTRUCTION BARRIER - REFER TO A704 FOR ADDITIONAL
INFORMATION
SHADED AREA IS NOT UNDER CURRENT CONSTRUCTION PHASE
UNLESS OTHERWISE NOTED - W ORK TO BE PERFORMED IN THE
SHADED AREAS MUST BE COORDINATED WITH COR FOUR WEEKS
PRIOR TO MINIMIZE MISSION IMPACT
NOTE:
AVAILABLE HAUL ROUTES FOR MOVEMENT OF CONSTRUCTION
MATERIALS AND REMOVAL OF DEBRIS ARE INDICATED ON THE
OVERALL DEMOLITION PLANS. HAUL ROUTE THROUGH AFMC
OCCUPIED/USED SPACES MUST OCCUR AT TIMES WHEN AFMC STAFF
IS NOT OCCUPYING THE BUILDING AND HAUL ROUTE MUST BE
CLEANED AT THE COMPLETION OF WORK FOR EACH SHIFT. NO
DEBRIS WILL BE ALLOWED IN HAUL ROUTES NOR A BUILD-UP OF DUST
OR OTHER CONSTRUCTION RELATED CONTAMINATES.
NOTE:
STAIRWELL IS NOT AVAILABLE FOR
CONSTRUCTION ACCESS.
NOTE:
AREA IN ENTRAPMENT AREA AVAILABLE FOR
MOVEMENT OF MATERIALS INTO AND DEBRIS
OUT OF B10262 DURING PHASE 1 WHILE
OPENING IN EXISTING WALL IS AVAILABLE
AND AFTER TRANSFORMER IS RELOCATED.
PROTECT AFMC STAFF FROM
CONSTRUCTION ACTIVITIES THROUGHOUT
PHASE 1
NOTE:
AREA MAY BE AVAILABLE FOR MOVEMENT OF
MATERIALS INTO AND DEBRIS OUT OF B10262
DURING PHASE 1 WHILE OPENING IN
EXISTING WALL IS AVAILABLE.
KEY PLAN
N
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
8'4' 16'
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
AD110A
AR
EA
D
EM
O
LI
TI
O
N F
LO
O
R P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
H
IG
H
LA
N D
S
PL
AZ
A
D R
IV
E
SU
IT
E
ST
. L O
U
IS
, M O
R . M
ES
SE
L
P.
M
C
EL
V
EN
EY
J.
C
O R
SO
N
D
EC
EM
BE
R
B10262 PHASE 1 - CERTIFIED FINAL
BA
SE
M E
N T
-A R
EA
-P
H
AS
E
AR
C
H
IT
EC
TU
R
AL
D
EM
O
LI
TI
O
N
1/8" = 1'-0"A1 BASEMENT DEMOLITION PLAN - AREA 10
151 REMOVE BOLLARDS
160 REMOVE CONCRETE PAVEMENT TO ACCOMMODATE CONSTRUCTION
192 REMOVE PLUMBING FIXTURES AND STALLS - TYPICAL. PATCH OPENINGS IN
FLOOR - REFER TO C1/A534
214 PROVIDE AND MAINTAIN AFMC STAFF EGRESS EXCEPT AS OTHERWISE NOTED.
REFER TO LIFE SAFETY PLANS
325 CONSTRUCTION BARRIER MUST BE DISMANTLED ONCE DEMOLITION AND NEW
WORK IS COMPLETED. COORDINATE REMOVAL OF TEMPORARY RATED
CONSTRUCTION BARRIER WITH NEW WORK IN PHASE 1
334 EXISTING CMU PARTITION IS 2 HOUR FIRE-RATED
409 REMOVE PLUMBING FIXTURES AND STALLS - TYPICAL. PATCH OPENINGS IN
FLOOR - REFER TO D1/A534
446 CONSTRUCTION BARRIER LOCATIONS SHOWN MUST BE COORDINATED WITH
COR PRIOR TO ERECTION
458 EXPOSE CONCRETE FOUNDATION AND CLEAN IN PREPARATION FOR BASEMENT
WATERPROOFING. REPAIR DAMAGED SURFACED PER SPECIFICATION SECTION
03 01 00 REHABILITATION OF CONCRETE
543 CONSTRUCTION ACCESS DOOR(S)
760 SAW CUT AND REMOVE PORTION EXISTING SLAB ON GRADE TO ACCOMMODATE
PLUMBING WORK. REPAIR FLOOR AS REQUIRED TO MATCH EXISTING ADJACENT
901 REMOVE PORTION OF EXISTING CONCRETE WALL AND ASSOCIATED
REINFORCING FOR NEW OPENINGS. HEIGHT OF OPENING MUST BE 7'-2".
PREPARE FLOOR SLAB WHERE REMOVED TO RECEIVE NEW WORK. REFER TO
NEW WORK
909 EXISTING PIPING AND CLEANOUTS TO REMAIN
924 REMOVE EXISTING PIPING AND CLEANOUTS
932 DASHED LINE REPRESENTS SHAFT LOCATION OF OPENING REQUIRED IN FLOOR
ABOVE FOR MECHANICAL
AD100A
AM
EN
D
M
EN
T 0 0
J A
N
W
2Q R
R
_C U
I_ C
F_ Pl an s-
AD201
A1
AD202
A1
AD203
C1
AD204
C1
AD206
A1
AD207
C1
AD208
C1
AD207
A1
AD206
C1
AD203
A1
AD201
C1
AD202
C1
BUILDING B10266 - NOT IN CONTRACT ENTRAPMENT AREA AND BUILDING B10262
A46
A35
A13
DEMOLISH LOADING
DOCK AND RAMP
DEMOLISH CONCRETE RAMP AND RETAINING WALLS
DEMOLISH EXISTING
CONCRETE RAMP
AND RETAINING
WALLS
DEMOLISH EXISTING
BUILDING B10277
A14
A14
A45
A68
A69
A13.1
A13.1
A66
A66
A93
A93
BUILDING B10264
BUILDING B10263
A92
A92
AD205
C1
AD205
A1
AD405
A2
A40
(V
IF
7'
0" (O
U T
TO
O
U T)
(VIF)
± 195' - 0" ( BUILDING - B10266 FUTURE PHASE)
FUTURE PHASES)
± 70' - 4" (VIF)
(VESTIBULE - PHASE 1 AND
(VIF)
± 484' - 2" (BUILDING B10262 - PHASE 1 AND FUTURE PHASES)
± 61' - 3" (VIF)
/2
VI
F)
2'
8"
(V
IF
/2
VI
F)
(VIF)
± 749' - 6" (OUT TO OUT)
214267
214214 214 214 214 214
267 267 267
(UNLESS OTHERWISE NOTED)
C1238
50' - 0" (MAXIMUM)
EQ
EQ
066 067
KEYED NOTES#
NOTE:
OPENINGS FOR NEW EXIT DISCHARGE
DOORS MAY BE USED FOR THE
MOVEMENT OF CONSTRUCTION
MATERIALS AND REMOVAL OF DEBRIS
FOR DURATION THAT THE OPENING IS
AVAILABLE PRIOR TO INSTALLATION OF
NEW EGRESS ELEMENT
NOTE:
OPENINGS FOR NEW EXIT DISCHARGE
DOORS MAY BE USED FOR THE
MOVEMENT OF CONSTRUCTION
MATERIALS AND REMOVAL OF DEBRIS
FOR DURATION THAT THE OPENING IS
AVAILABLE PRIOR TO INSTALLATION OF
NEW EGRESS ELEMENT
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EGRESS STAIRWELLS AND
EXIT DISCHARGE LOCATIONS DURING
TIMES WHICH BUILDING IS OCCUPIED BY
AFMC STAFF. DO NOT USE STAIR FOR
REMOVAL OF CONSTRUCTION DEBRIS
EXCEPT THAT WHICH IS GENERATED IN
STAIRWELL.
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EGRESS STAIRWELLS AND
EXIT DISCHARGE LOCATIONS DURING
TIMES WHICH BUILDING IS OCCUPIED BY
AFMC STAFF
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EGRESS STAIRWELLS AND
EXIT DISCHARGE LOCATIONS DURING
TIMES WHICH BUILDING IS OCCUPIED BY
AFMC STAFF
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EGRESS STAIRWELLS AND
EXIT DISCHARGE LOCATIONS DURING
TIMES WHICH BUILDING IS OCCUPIED BY
AFMC STAFF
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EGRESS STAIRWELLS AND
EXIT DISCHARGE LOCATIONS DURING
TIMES WHICH BUILDING IS OCCUPIED BY
AFMC STAFF
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EXIT DISCHARGE FOR AFMC
STAFF DURING TIMES WHICH THE
BUILDING IS OCCUPIED UNTIL SUCH TIME
AS THE CONSTRUCTION SCHEDULE
REQUIRES DEMOLITION/CONSTRUCTION
ON SAME. UPON COMPLETION OF NEW
EXIT DISCHARGE AND STAIRS, PLACE
ELEMENT BACK IN SERVICE TO AFMC
OCCUPANTS DURING TIMES OF
OCCUPANCY
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EXIT DISCHARGE FOR AFMC
STAFF DURING TIMES WHICH THE
BUILDING IS OCCUPIED UNTIL SUCH TIME
AS THE CONSTRUCTION SCHEDULE
REQUIRES DEMOLITION/CONSTRUCTION
ON SAME. UPON COMPLETION OF NEW
EXIT DISCHARGE AND STAIRS, PLACE
ELEMENT BACK IN SERVICE TO AFMC
OCCUPANTS DURING TIMES OF
OCCUPANCY
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EGRESS STAIRWELLS AND
EXIT DISCHARGE LOCATIONS DURING
TIMES WHICH BUILDING IS OCCUPIED BY
AFMC STAFF
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
MEANS OF EGRESS DISCHARGE AT THIS
LOCATION DURING TIMES WHICH
BUILDING IS OCCUPIED BY AFMC STAFF
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
MEANS OF EGRESS DISCHARGE AT THIS
LOCATION DURING TIMES WHICH
BUILDING IS OCCUPIED BY AFMC STAFF.
PROVIDE CLEAR PATHWAY ON
EXTERIOR OF BUILDING TO STREET
NOTE:
PRIOR TO DEMOLITION OF EXISTING NORTH VESTIBULE FOR NEW
CONSTRUCTION, ERECT ABA-COMPLIANT ALUMINUM MODULAR
ACCESS RAMP FROM CURB TO NEW ENTRANCE DOOR. PROTECT
AFMC OCCUPIED PORTIONS OF BUILDING, INCLUDING ACCESS
AND EGRESS PATHWAYS BEHIND SECURED CONSTRUCTION
BARRIER.
TEMPORARY 5-0" WIDE ABA-COMPLIANT ACCESS TO AFMC
OCCUPIED SPACE MAY BE DEMOLISHED IN PREPARATION OF
FINAL PHASE 1 FINISHES AFTER NORTH VESTIBULE IS
FUNCTIONAL AND ABLE TO SERVE AS AN ABA-COMPLIANT
ENTRANCE FOR AFMC STAFF ACCESSING THE BUILDING.
NOTE:
DURING A PORTION OF PHASE 1 CONSTRUCTION BUILDING
B10262 WILL NOT HAVE AN ACCESSIBLE ELEVATOR
FIRST FLOOR PHASE 1 AREAS:
PHASE 1 CONSTRUCTION: 69,852SF
EXISTING SPACE (NOT UNDER CONSTRUCTION): 115,921SF
BUILDING B10262 TOTAL: 185,773SF
(INCLUDES B10263, B10264 AND VESTIBULE/CONNECTORS)
NOTE:
AREA IN ENTRAPMENT AREA AVAILABLE
FOR MOVEMENT OF MATERIALS INTO
AND DEBRIS OUT OF B10262 DURING
PHASE 1 WHILE OPENING IN EXISTING
WALL IS AVAILABLE AND AFTER
TRANSFORMER IS RELOCATED.
PROTECT AFMC STAFF FROM
CONSTRUCTION ACTIVITIES
THROUGHOUT PHASE 1.
NOTE:
AREA MAY BE AVAILABLE FOR
MOVEMENT OF MATERIALS INTO AND
DEBRIS OUT OF B10262 DURING PHASE 1
WHILE OPENING IN EXISTING WALL IS
AVAILABLE.
NOTE:
LOADING DOCK AND RAMP AVAILABLE
FOR MOVEMENT OF MATERIALS INTO
AND DEBRIS OUT OF B10262 DURING
PHASE 1.
NOTE:
AREA MAY BE AVAILABLE FOR
MOVEMENT OF DEBRIS OUT OF B10262
DURING PHASE 1 WHILE OPENING IN
EXISTING WALL IS AVAILABLE.
NOTE:
AREA MAY BE AVAILABLE FOR
MOVEMENT OF DEBRIS OUT OF B10262
DURING PHASE 1 WHILE OPENING IN
EXISTING WALL IS AVAILABLE.
GENERAL NOTES - DEMOLITION DEMOLITION LEGEND
REMOVE WALL /
PARTITION
REMOVE DOOR
REMOVE DOORS
CONSTRUCTION
BARRIER
REMOVE
CONSTRUCTION
BARRIER
1. REFER TO AD001 FOR GENERAL DEMOLITION NOTES
2. EXISTING STAIRS 1 THROUGH 6 INCLUSIVE MUST NOT BE
USED TO HAUL DEBRIS EXCEPT FOR DEMOLITION W ORK
WITHIN STAIRS 5 AND 6.
SHADED AREA IS NOT UNDER CURRENT
CONSTRUCTION PHASE UNLESS OTHERWISE NOTED -
WORK TO BE PERFORMED IN THE SHADED AREAS
MUST BE COORDINATED WITH COR FOUR WEEKS
PRIOR TO MINIMIZE MISSION IMPACT
HAUL ROUTE FOR
MATERIALS AND DEBRIS.
LIMITED TO HOURS OF
OPERATION DURING TIMES
WHEN AFMC STAFF IS NOT
OCCUPYING THE BUILDING
TEMPORARY
CONSTRUCTION AREA
TEMPORARY ABA ACCESS
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
AD100B
O
VE
R A
LL
D
EM
O
LI
TI
O N
F
LO
O R
P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
H
IG
H
LA
N D
S
PL
AZ
A
D R
IV
E
SU
IT
E
ST
. L O
U
IS
, M O
R . M
ES
SE
L
P.
M
C
EL
V
EN
EY
J.
C
O R
SO
N
D
EC
EM
BE
R
B10262 PHASE 1 - CERTIFIED FINAL
FI
R
ST
F
LO
O
R
PH
AS
E
AR
C
H
IT
EC
TU
R
AL
D
EM
O
LI
TI
O
N
1/32" = 1'-0"A1 FIRST FLOOR DEMOLITION PLAN - OVERALL
(570 LINEAR FEET AND 5,000 SQUARE FEET)
(50 SQUARE FEET AND 20 LINEAR FEET)
(200 SQUARE FEET AND 60 LINEAR FEET
(300 LINEAR FEET)
(123,151 SQUARE FEET)
(1,600 SQUARE FEET)
(15,900 SQUARE FEET)
(1,600 SQUARE FEET)
(1 EACH)
(16 EACH)
(2,700 SQUARE FEET AND 60 LINEAR FEET)
0 32'16' 64'
N
G010
066 PARTITION TYPE '0M' - REFER TO A703 FOR ADDITIONAL INFORMATION. PT-1 AND RB-1 FINISH ON BOTH SIDES 067 DOOR AND PARTITION MUST BE DIMANTLED UPON COMPLETION OF NORTH VESTIBULE. PATCH TO MATCH EXISTING ADJACENT 214 PROVIDE AND MAINTAIN AFMC STAFF EGRESS EXCEPT AS OTHERWISE NOTED. REFER TO LIFE SAFETY PLANS 217 TEMPORARY ABA-COMPLIANT ALUMINUM MODULAR ACCESS RAMP FROM PARKING LOT CURB TO NEW ENTRANCE DOOR -
INSTALL PRIOR TO DEMOLITION OF NORTH VESTIBULE. REMOVE UPON COMPLETION OF FUNCTIONAL AND ABA-COMPLIANT NORTH VESTIBULE THAT CAN SERVE AS ENTRANCE FOR AFMC STAFF ACCESSING B10262. REFER TO CIVIL GRADING DRAWINGS
FOR LOCATIONS OF ABA PARKING
267 INSTALL EXIT SIGNAGE FOR AFMC STAFF DURING PHASE 1 CONSTRUCTION
A13 ABATE ASBESTOS CONTAINING LAYERED PAPER PIPE INSULATION
A13.1 ABATE ADDITIONAL ASBESTOS CONTAINING PAPER PIPE INSULATION THROUGHOUT PHASE 1 (15,000 SQUARE FEET AND 1,250
LINEAR FEET)
A14 ABATE ASBESTOS CONTAINING FLOOR TILE AND BLACK MASTIC THROUGHOUT
A35 ABATE ASBESTOS CONTAINING PIPE INSULATION DEBRIS
A40 ABATE ASBESTOS CONTAINING AIR CELL PIPE INSULATION
A45 ABATE ASBESTOS CONTAINING PIPE INSULATION WITH DEBRIS
A46 ABATE ASBESTOS CONTAINING ACOUSTICAL PLASTER
A66 ABATE ASBESTOS CONTAINING FIRE DOORS THROUGHOUT PHASE 1
A68 ABATE PRESUMED ASBESTOS CONTAINING LAYER OF BLACK MATERIAL IN MAIN LOBBY MEN'S RESTROOM INSIDE SHAFT BEHIND
WALL
A69 ABATE PRESUMED ASBESTOS CONTAINING LAYER OF BLACK MATERIAL IN MAIN LOBBY WOMEN'S RESTROOM INSIDE SHAFT
BEHIND WALL
A92 ABATE ASBESTOS CONTAINING WALL TEXTURE THROUGHOUT PHASE 1
A93 ABATE ASBESTOS CONTAINING ELEVATOR DOORS THROUGHOUT PHASE 1
AM
EN
D
M
EN
T 0 0
J A
N
W
2Q R
R
_C U
I_ C
F_ Pl an s-
BUILDING B10266 - NOT IN CONTRACT ENTRAPMENT AREA AND BUILDING B10262
A13
A14
A66
A92
A13 A14
A13 A14
A13
A14
A13 A14 A13
A14 A14
A66 A13
A14
A13
A92
A13
A14
A13
A14
A92
A13 A14
A13
A14
A13
A14
A92
A13
A14
A66
A92
(V
IF
7'
0"
(O U
T
TO
O U
T)
(VIF)
195' - 0" ( BUILDING - B10266 FUTURE PHASE)
FUTURE PHASES)
± 70' - 4" (VIF)
(VESTIBULE - PHASE 1 AND
(VIF)
± 484' - 2" (BUILDING B10262 - PHASE 1 AND FUTURE PHASES) (VIF)
± 61' - 3"
(V
IF
/2
2'
8"
(V
IF
(V
IF
/2
(VIF)
749' - 6" (OUT TO OUT)
2'
O U
T
TO
O U
T)
(UNLESS OTHERWISE NOTED)
C2225
C2226
50' - 0" (MAXIMUM)
EQ
EQ
50' - 0" (MAXIMUM)
EQ
EQ
GENERAL NOTES - DEMOLITION DEMOLITION LEGEND
REMOVE WALL /
PARTITION
REMOVE DOOR
REMOVE DOORS
CONSTRUCTION
BARRIER
REMOVE
CONSTRUCTION
BARRIER
1. REFER TO AD001 FOR GENERAL DEMOLITION NOTES
2. EXISTING STAIRS 1 THROUGH 6 INCLUSIVE MUST NOT BE
USED TO HAUL DEBRIS EXCEPT FOR DEMOLITION W ORK
WITHIN STAIRS 5 AND 6.
SHADED AREA IS NOT UNDER CURRENT
CONSTRUCTION PHASE UNLESS OTHERWISE NOTED -
WORK TO BE PERFORMED IN THE SHADED AREAS
MUST BE COORDINATED WITH COR FOUR WEEKS
PRIOR TO MINIMIZE MISSION IMPACT
HAUL ROUTE FOR
MATERIALS AND DEBRIS.
LIMITED TO HOURS OF
OPERATION DURING TIMES
WHEN AFMC STAFF IS NOT
OCCUPYING THE BUILDING
TEMPORARY
CONSTRUCTION AREA
TEMPORARY ABA ACCESS
KEYED NOTES#
NOTE:
MAINTAIN EXISTING EGRESS ACCESS
WAY UNTIL TELECOM ROOM IS
CONSTRUCTED AND DOORS ARE
INSTALLED IN CONSTRUCTION BARRIER
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EGRESS STAIRWELLS
DURING TIMES WHICH BUILDING IS
OCCUPIED BY AFMC STAFF
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EGRESS STAIRWELLS
DURING TIMES WHICH BUILDING IS
OCCUPIED BY AFMC STAFF
NOTE:
TALL WINDOW IS AVAILABLE FOR
DISPOSAL OF DEBRIS AND MATERIAL
HANDLING
NOTE:
TALL WINDOW IS AVAILABLE FOR
DISPOSAL OF DEBRIS AND MATERIAL
HANDLING
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EGRESS STAIRWELLS
DURING TIMES WHICH BUILDING IS
OCCUPIED BY AFMC STAFF
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EGRESS STAIRWELLS
DURING TIMES WHICH BUILDING IS
OCCUPIED BY AFMC STAFF
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EGRESS STAIRWELLS
DURING TIMES WHICH BUILDING IS
OCCUPIED BY AFMC STAFF
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
ACCESS TO EGRESS STAIRWELLS
DURING TIMES WHICH BUILDING IS
OCCUPIED BY AFMC STAFF
NOTE:
MAINTAIN A FREE AND UNOBSTRUCTED
MEANS OF EGRESS DISCHARGE AT THIS
LOCATION DURING TIMES WHICH
BUILDING IS OCCUPIED BY AFMC STAFF
SECOND FLOOR PHASE 1 AREAS:
PHASE 1 CONSTRUCTION: 29,137SF
EXISTING SPACE (NOT UNDER CONSTRUCTION): 149,970SF
BUILDING B10262 TOTAL: 179,107SF
(INCLUDES VESTIBULE/CONNECTORS)
NOTE:
AREA IN ENTRAPMENT AREA AVAILABLE
FOR MOVEMENT OF MATERIALS INTO
AND DEBRIS OUT OF B10262 DURING
PHASE 1 WHILE OPENING IN EXISTING
WALL IS AVAILABLE AND AFTER
TRANSFORMER IS RELOCATED.
PROTECT AFMC STAFF FROM
CONSTRUCTION ACTIVITIES
THROUGHOUT PHASE 1.
NOTE:
AREA MAY BE AVAILABLE FOR
MOVEMENT OF DEBRIS OUT OF B10262
DURING PHASE 1 WHILE OPENING IN
EXISTING WALL IS AVAILABLE.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
AD100C
O
VE
R
AL
L D
EM
O
LI
TI
O N
P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
H
IG
H
LA
N D
S
PL
AZ
A
D R
IV
E
SU
IT
E
ST
. L O
U
IS
, M O
R . M
ES
SE
L
P.
M
C
EL
V
EN
EY
J.
C
O R
SO
N
D
EC
EM
BE
R
B10262 PHASE 1 - CERTIFIED FINAL
SE
C
O N
D F
LO
O
R
P H
AS
E
AR
C
H
IT
EC
TU
R
AL
D
EM
O
LI
TI
O
N
1/32" = 1'-0"A1 SECOND FLOOR DEMOLITION PLAN - OVERALL
066 PARTITION TYPE '0M' - REFER TO A703 FOR ADDITIONAL INFORMATION. PT-1 AND
RB-1 FINISH ON BOTH SIDES
A13 ABATE ASBESTOS CONTAINING LAYERED PAPER PIPE INSULATION
A14 ABATE ASBESTOS CONTAINING FLOOR TILE AND BLACK MASTIC THROUGHOUT
A66 ABATE ASBESTOS CONTAINING FIRE DOORS THROUGHOUT PHASE 1
A92 ABATE ASBESTOS CONTAINING WALL TEXTURE THROUGHOUT PHASE 1
(43,784 SQUARE FEET)
(800 LINEAR FEET AND 4,000 SQUARE FEET)
(6 TOTAL)
(4,750 SQUARE FEET)
G010
0 32'16' 64'
N
AM
EN
D
M
EN
T 0 0
J A
N
W
2Q R
R
_C U
I_ C
F_ Pl an s-
E
D
C
B
A
18 19 20 21 22 23 24 2522E 23E
M
AT
C H
LI
N
E
A1
AD
4C
MATCHLINE
A1 AD102C
FOR PROTOCOL OF
STAIR 6 - REFER TO
LS002 AND ENLARGED
STAIR PLAN
10' - 3"
VIF
6' - 2"
CB
CB
CB
CB
CB
415446 415
CONTINUED ON AD102C
421 409
409409409
EXISTING BUILDING B10263 -
REFER TO AD401 AND AD402
EXISTING BUILDING B10264 -
REFER TO AD401 AND AD402
CB
446446 305
446305
2 1/2" 12' - 0 1/2"
7'
/2
CB
4 CB
CB
CB
9' - 6 3/4"
CB
543543
C2213 C2214
C2208
C2211
C
PROTECT EXISTING
PARTITION AND
DOOR IN PLACE
C2221
1' - 2" 1' - 2"
2'
1/
2" 3'
1/ 2"
C
CB
1/
2"
KEYED NOTES - DEMOLITION#
DEMOLITION LEGEND
REMOVE WALL / PARTITION
REMOVE DOOR
REMOVE DOORS
CONSTRUCTION BARRIER - REFER TO A704 FOR ADDITIONAL
INFORMATION
SHADED AREA IS NOT UNDER CURRENT CONSTRUCTION PHASE
UNLESS OTHERWISE NOTED - W ORK TO BE PERFORMED IN THE
SHADED AREAS MUST BE COORDINATED WITH COR FOUR WEEKS
PRIOR TO MINIMIZE MISSION IMPACT
NOTE:
AVAILABLE HAUL ROUTES FOR MOVEMENT OF CONSTRUCTION
MATERIALS AND REMOVAL OF DEBRIS ARE INDICATED ON THE
OVERALL DEMOLITION PLANS. HAUL ROUTE THROUGH AFMC
OCCUPIED/USED SPACES MUST OCCUR AT TIMES WHEN AFMC STAFF
IS NOT OCCUPYING THE BUILDING AND HAUL ROUTE MUST BE
CLEANED AT THE COMPLETION OF WORK FOR EACH SHIFT. NO
DEBRIS WILL BE ALLOWED IN HAUL ROUTES NOR A BUILD-UP OF DUST
OR OTHER CONSTRUCTION RELATED CONTAMINATES.
NOTE:
THIS LOCATION MAY BE USED FOR MATERIAL
HANDLING INTO AND CONSTRUCTION DEBRIS
REMOVAL FROM FLOOR DURING TIMES WHEN
AFMC STAFF IS NOT OCCUPYING THE
BUILDING AND PRIOR TO CONSTRUCTION OF
NEW EXTERIOR EGRESS STAIR. OPENING
MUST BE MADE WEATHERTIGHT AND
INSULATED AND SECURED SAFE AT TIMES
WHEN AFMC STAFF OCCUPIES THE BUILDING
NOTE:
THIS LOCATION MAY BE USED FOR MATERIAL
HANDLING INTO AND CONSTRUCTION DEBRIS
REMOVAL FROM FLOOR DURING TIMES WHEN
AFMC STAFF IS NOT OCCUPYING THE
BUILDING AND PRIOR TO CONSTRUCTION OF
NEW EXTERIOR EGRESS STAIR. OPENING
MUST BE MADE WEATHERTIGHT AND
INSULATED
NOTE:
DOORS MUST MAINTAIN INTEGRITY OF FIRE
RATED STAIRWELL AND UNINTERRUPTED USE
OF STAIR FOR EGRESS UNTILL SUCH TIME AS
STAIR 6 IS CLOSED FOR RECONSTRUCTION.
REFER TO LIFE SAFETY SEQUENCE SHEETS
G100A.2 - G100C.4
NOTE:
STAIRWELL IS NOT AVAILABLE FOR
CONSTRUCTION ACCESS OTHER THAN WORK
IN STAIRWELL
KEY PLAN
N
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
8'4' 16'
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
AD101C
AR
EA
D
EM
O
LI
TI
O
N F
LO
O
R P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
H
IG
H
LA
N D
S
PL
AZ
A
D R
IV
E
SU
IT
E
ST
. L O
U
IS
, M O
R . M
ES
SE
L
P.
M
C
EL
V
EN
EY
J.
C
O R
SO
N
D
EC
EM
BE
R
B10262 PHASE 1 - CERTIFIED FINAL
SE
C
O N
D F
LO
O
R
AR
EA
PH
AS
E
AR
C
H
IT
EC
TU
R
AL
D
EM
O
LI
TI
O
N
1/8" = 1'-0"A1 SECOND FLOOR DEMOLITION PLAN - AREA 1
214 PROVIDE AND MAINTAIN AFMC STAFF EGRESS EXCEPT AS OTHERWISE NOTED.
REFER TO LIFE SAFETY PLANS
305 CONSTRUCTION BARRIER MUST BE DISMANTLED ONCE CUTTING OF SLAB
OPENINGS HAS BEEN COMPLETED AND 2 HOUR SHAFT WALLS ARE INSTALLED.
COORDINATE REMOVAL OF TEMPORARY, RATED CONSTRUCTION BARRIER WITH
NEW WORK IN PHASE 1
409 REMOVE PLUMBING FIXTURES AND STALLS - TYPICAL. PATCH OPENINGS IN
FLOOR - REFER TO D1/A534
415 REMOVE CONCRETE SLAB AS REQUIRED FOR MECHANICAL SHAFT - REFER TO
STRUCTURAL AND MECHANICAL TO COORDINATE OPENING SIZE
421 REMOVE CASEWORK / COUNTERTOPS
446 CONSTRUCTION BARRIER LOCATIONS SHOWN MUST BE COORDINATED WITH
COR PRIOR TO ERECTION
543 CONSTRUCTION ACCESS DOOR(S)
908 REMOVE EXISTING PIPING AND CLEANOUTS. PATCH FLOORS TO REMAIN - REFER
TO D1 AND C1 ON A534
999 REPLACE EXISTING DOOR(S) AND FRAME AND PROVIDE NEW DOOR(S) AND
FRAME FOR CONSTRUCTION ACCESS. DOOR(S) WITH CLOSER. PATCH
PARTITION AT DOOR OPENING TO PROVIDE A SMOOTH, CONTINUOUS SURFACE
AT THE DOOR OPENING.
AD100C
AM
EN
D
M
EN
T 0 0
D
EC
AM
EN
D M
EN
T
0 0
J
A N
W
2Q R
R
_C U
I_ C
F_ Pl an s-
T
S
R
Q
P
O
N
M
1 2 3 4 51-J
1-6
1-5
1-4.5
1-4
1-3
1-2
1-1
M
AT
C H
LI
N
E
A1
AD
9C
MATCHLINE
A1 AD111C
NOTE:
STAIRWELL IS NOT AVAILABLE FOR
CONSTRUCTION ACCESS.
KEYED NOTES - DEMOLITION#
DEMOLITION LEGEND
REMOVE WALL / PARTITION
REMOVE DOOR
REMOVE DOORS
CONSTRUCTION BARRIER - REFER TO A704 FOR ADDITIONAL
INFORMATION
SHADED AREA IS NOT UNDER CURRENT CONSTRUCTION PHASE
UNLESS OTHERWISE NOTED - W ORK TO BE PERFORMED IN THE
SHADED AREAS MUST BE COORDINATED WITH COR FOUR WEEKS
PRIOR TO MINIMIZE MISSION IMPACT
NOTE:
AVAILABLE HAUL ROUTES FOR MOVEMENT OF CONSTRUCTION
MATERIALS AND REMOVAL OF DEBRIS ARE INDICATED ON THE
OVERALL DEMOLITION PLANS. HAUL ROUTE THROUGH AFMC
OCCUPIED/USED SPACES MUST OCCUR AT TIMES WHEN AFMC STAFF
IS NOT OCCUPYING THE BUILDING AND HAUL ROUTE MUST BE
CLEANED AT THE COMPLETION OF…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .