W912QR22R0028_Plans_PH1_Vol4-0000.pdf
PDF 14 MB Posted
- Solicitation number
- W912QR22R0028
About this file
This solicitation notice provides details for a renovation project at Wright-Patterson Air Force Base in Ohio. The U.S. Army Corps of Engineers Louisville District plans to issue a request for proposal for design and construction services to renovate over 60,000 square feet of the Air Force Materiel Command Headquarters building. Renovations will include replacement of HVAC, electrical, plumbing and telecommunications systems, as well as interior finishes, windows and thermal insulation. Exterior improvements comprise waterproofing and site work. The contract duration is estimated at 1,095 calendar days with anticipated work commencing in November 2022. Offerors are required to register in the System for Award Management and proposals will be evaluated using best value tradeoff. The estimated value ranges from $100-250 million.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Controlled by: USACE-LRL-ED-MA CUI Category(ies):
LDC or Distribution Statement: N/A POC: Blake Gevedon Contracting Specialist william.b.gevedon@usace.army.mi 502.315.6791
Materials shall be submitted to potential offerors currently certified in the Joint Certification Program (JCP) only.
WRIGHT-PATTERSON AIR
FORCE BASE
STATE R
O
UTE 4
IN
T
E R
S T
A T
E
INTERSTATE 70
S T
A T
E R
O U
T E
STATE ROUTE 4
STATE ROUTE 444
T ROAD
A S
T R
E E
T
O G
D E
N A
V E
N U
E
C H
ID
L
A W
R O
A D
B R
O A D
N R
O A
D
A STREET
S
TA
TE
R
O U
TE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I
D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
1 2 3 4 5
D
C
B
A
US Army Corps of Engineers ®
P2 NO.:
ISSUE DATE:
VOLUME:
CUI
CUI
C U
I
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E D
A Y
T O
N
O H
IO
R E
P A
IR
/R
E N
O V
A T
E A
F M
C H
Q B
U
IL
D
IN
G
B
P
H A
S E
SOLICITATION NO.:
PHASEREPAIR/RENOVATE AFMC HEADQUARTERS BUILDING
B 10262
W912QR21R0028
CONTROLLED BY: USACE
CONTROLLED BY: LOUISVILLE DISTRICT
CUI CATEGORY: CUI BASIC
DISTRIBUTION/DISSEMINATION CONTROLS: DISTRO C
POC: STEVE SKAGGS, 502-315-6368
B262 PHASE
P
N O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
J
B E
N S
O N
PLAN NORTH PLAN NORTHTRUE NORTH TRUE NORTH
G004
V O
L U
M E
P H
A S
E
C O
V E
R S
H E
E T
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
J A
C O
B S
E N
G
IN
E E
R
IN
G G
R O
U P
I N
C
N
B
R O
A D
W A
Y S
T
L O
U
IS
M
O
R
M E
S S
E L
N
R E
N D
L E
M A
N
J
C O
R S
O N
O C
T O
B E
R
W
Q R
R
X X
X X
B10262 PHASE 1 - 90% FINAL REVISED - NOT FOR CONSTRUCTION
LOUISVILLE DISTRICT
475429
20 OCTOBER 2022
F
IR
E P
R O
T E
C T
IO
N
WRIGHT-PATTERSON AIR FORCE BASE
DAYTON, OHIO 45433
B10262 PHASE 1 - 90% FINAL REVISED - NOT FOR CONSTRUCTION
G E
N E
R A
L
FIRE PROTECTION
VICINITY MAP LOCATION MAP
W
2Q R
R
_P la ns _P
H 1_
Vo l4
-0
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
H2EDEJDL
Text Box 10 November 2022
W912QR22R0028
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I
D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
1 2 3 4 5
D
C
B
A
CUI
CUI
C U
I
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E D
A Y
T O
N
O H
IO
R E
P A
IR
/R
E N
O V
A T
E A
F M
C H
Q B
U
IL
D
IN
G
B
P
H A
S E
B262 PHASE
P
N O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
J
B E
N S
O N
G012
V O
L U
M E
P H
A S
E
S H
E E
T I
N D
E X
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
J A
C O
B S
E N
G
IN
E E
R
IN
G G
R O
U P
I N
C
N
B
R O
A D
W A
Y S
T
L O
U
IS
M
O
R
M E
S S
E L
N
R E
N D
L E
M A
N
J
C O
R S
O N
O C
T O
B E
R
W
Q R
R
X X
X X
B10262 PHASE 1 - 90% FINAL REVISED - NOT FOR CONSTRUCTION
F
IR
E P
R O
T E
C T
IO
N
G E
N E
R A
L
FXD112B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 12 - PHASE 1
FXD100C OVERALL SECOND FLOOR DEMOLITION PLAN - SECOND FLOOR - PHASE 1
FXD101C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 1 - PHASE 1
FXD102C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 2 - PHASE 1
FXD103C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 3 - PHASE 1
FXD104C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 4 - PHASE 1
FXD105C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 5 - PHASE 1
FXD106C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 6 - PHASE 1
FXD107C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 7 - PHASE 1
FXD108C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 8 - PHASE 1
FXD109C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 9 - PHASE 1
FXD110C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 10 - PHASE 1
FXD111C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 11 - PHASE 1
FXD112C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 12 - PHASE 1
FX100A OVERALL BASEMENT PLAN - BASEMENT - PHASE 1
FX101A AREA CEILING PLAN - BASEMENT - AREA 1 - PHASE 1
FX102A AREA CEILING PLAN - BASEMENT - AREA 2 - PHASE 1
FX103A AREA CEILING PLAN - BASEMENT - AREA 3 - PHASE 1
FX104A AREA CEILING PLAN - BASEMENT - AREA 4 - PHASE 1
FX105A AREA CEILING PLAN - BASEMENT - AREA 5 - PHASE 1
FX106A AREA CEILING PLAN - BASEMENT - AREA 6 - PHASE 1
FX107A AREA CEILING PLAN - BASEMENT - AREA 7 - PHASE 1
FX108A AREA CEILING PLAN - BASEMENT - AREA 8 - PHASE 1
FX109A AREA CEILING PLAN - BASEMENT - AREA 9 - PHASE 1
FX110A AREA CEILING PLAN - BASEMENT - AREA 10 - PHASE 1
FX111A AREA CEILING PLAN - BASEMENT - AREA 11 - PHASE 1
FX112A AREA CEILING PLAN - BASEMENT - AREA 12 - PHASE 1
FX100B OVERALL FIRST FLOOR PLAN - FIRST FLOOR - PHASE 1
FX101B AREA CEILING PLAN - FIRST FLOOR - AREA 1 - PHASE 1
FX102B AREA CEILING PLAN - FIRST FLOOR - AREA 2 - PHASE 1
FX103B AREA CEILING PLAN - FIRST FLOOR - AREA 3 - PHASE 1
FX104B AREA CEILING PLAN - FIRST FLOOR - AREA 4 - PHASE 1
FX105B AREA CEILING PLAN - FIRST FLOOR - AREA 5 - PHASE 1
FX106B AREA CEILING PLAN - FIRST FLOOR - AREA 6 - PHASE 1
FX107B AREA CEILING PLAN - FIRST FLOOR - AREA 7 - PHASE 1
FX108B AREA CEILING PLAN - FIRST FLOOR - AREA 8 - PHASE 1
FX109B AREA CEILING PLAN - FIRST FLOOR - AREA 9 - PHASE 1
FX110B AREA CEILING PLAN - FIRST FLOOR - AREA 10 - PHASE 1
FX111B AREA CEILING PLAN - FIRST FLOOR - AREA 11 - PHASE 1
FX112B AREA CEILING PLAN - FIRST FLOOR - AREA 12 - PHASE 1
FX100C OVERALL SECOND FLOOR PLAN - SECOND FLOOR - PHASE 1
FX101C AREA CEILING PLAN - SECOND FLOOR - AREA 1 - PHASE 1
FX102C AREA CEILING PLAN - SECOND FLOOR - AREA 2 - PHASE 1
FX103C AREA CEILING PLAN - SECOND FLOOR - AREA 3 - PHASE 1
FX104C AREA CEILING PLAN - SECOND FLOOR - AREA 4 - PHASE 1
FX105C AREA CEILING PLAN - SECOND FLOOR - AREA 5 - PHASE 1
FX106C AREA CEILING PLAN - SECOND FLOOR - AREA 6 - PHASE 1
FX107C AREA CEILING PLAN - SECOND FLOOR - AREA 7 - PHASE 1
FX108C AREA CEILING PLAN - SECOND FLOOR - AREA 8 - PHASE 1
FX109C AREA CEILING PLAN - SECOND FLOOR - AREA 9 - PHASE 1
FX110C AREA CEILING PLAN - SECOND FLOOR - AREA 10 - PHASE 1
FX111C AREA CEILING PLAN - SECOND FLOOR - AREA 11 - PHASE 1
FX112C AREA CEILING PLAN - SECOND FLOOR - AREA 12 - PHASE 1
FX500 FIRE SUPPRESSION DETAILS - PHASE 1
FX501 FIRE SUPPRESSION DETAILS - PHASE 1
FX502 FIRE SUPPRESSION DETAILS - PHASE 1
FX503 FIRE SUPPRESSION DETAILS - PHASE 1
FX504 STANDPIPE RISER SCHEMATIC - PHASE 1
FA001 FIRE ALARM AND MASS NOTIFICATION GENERAL NOTES,SYMBOLS, AND
ABBREVIATIONS - PHASE 1 -
FAD100A OVERALL BASEMENT DEMOLITION PLAN - BASEMENT - PHASE 1
FAD101A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 1 - PHASE 1
FAD102A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 2 - PHASE 1
FAD103A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 3 - PHASE 1
FAD104A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 4 - PHASE 1
FAD105A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 5 - PHASE 1
FAD106A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 6 - PHASE 1
FAD107A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 7 - PHASE 1
FAD108A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 8 - PHASE 1
FAD109A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 9 - PHASE 1
FAD110A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 10 -PHASE 1
FAD111A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 11 - PHASE 1
FAD112A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 12 - PACKAGE A
FAD100B OVERALL FIRST FLOOR DEMOLITION PLAN - FIRST FLOOR - PHASE 1
FAD101B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 1 - PHASE 1
FAD102B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 2 - PHASE 1
FAD103B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 3 - PHASE 1
FAD104B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 4 - PHASE 1
FAD105B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 5 - PHASE 1
FAD106B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 6 - PHASE 1
FAD107B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 7 - PHASE 1
FAD108B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 8 - PHASE 1
FAD109B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 9 - PHASE 1
FAD110B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 10 -PHASE 1
FAD111B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 11 - PHASE 1
FAD112B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 12 - PHASE 1
FAD100C OVERALL SECOND FLOOR DEMOLITON PLAN - SECOND FLOOR - PHASE 1
FAD101C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 1 - PHASE 1
FAD102C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 2 - PHASE 1
FAD103C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 3 - PHASE 1
FAD104C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 4 - PHASE 1
FAD105C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 5 PHASE 1
FAD106C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 6 - PHASE 1
FAD107C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 7 - PHASE 1
FAD108C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 8 - PHASE 1
FAD109C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 9 - PHASE 1
FAD110C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 10 - PHASE 1
FAD111C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 11 - PHASE 1
FAD112C AREA DEMOLITION CEILING PLAN - SECOND FLOOR - AREA 12 -PHASE 1
FA100A OVERALL BASEMENT PLAN - BASEMENT - PHASE 1
FA101A AREA CEILING PLAN - BASEMENT - AREA 1 - PHASE 1
FA102A AREA CEILING PLAN - BASEMENT - AREA 2 - PHASE 1
FA103A AREA CEILING PLAN - BASEMENT - AREA 3 - PHASE 1
FA104A AREA CEILING PLAN - BASEMENT - AREA 4 - PHASE 1
FA105A AREA CEILING PLAN - BASEMENT - AREA 5 - PHASE 1
FA106A AREA CEILING PLAN - BASEMENT - AREA 6 - PHASE 1
FA107A AREA CEILING PLAN - BASEMENT - AREA 7 - PHASE 1
FA108A AREA CEILING PLAN - BASEMENT - AREA 8 - PHASE 1
FA109A AREA CEILING PLAN - BASEMENT - AREA 9 - PHASE 1
FA110A AREA CEILING PLAN - BASEMENT - AREA 10 - PHASE 1
FA111A AREA CEILING PLAN - BASEMENT - AREA 11 - PHASE 1
FA112A AREA CEILING PLAN - BASEMENT - AREA 12 - PHASE 1
FA100B OVERALL FIRST FLOOR PLAN - FIRST FLOOR - PHASE 1
FA101B AREA CEILING PLAN - FIRST FLOOR - AREA 1 - PHASE 1
FA102B AREA CEILING PLAN - FIRST FLOOR - AREA 2 - PHASE 1
FA103B AREA CEILING PLAN - FIRST FLOOR - AREA 3 - PHASE 1
FA104B AREA CEILING PLAN - FIRST FLOOR - AREA 4 - PHASE 1
FA105B AREA CEILING PLAN - FIRST FLOOR - AREA 5 - PHASE 1
FA106B AREA CEILING PLAN - FIRST FLOOR - AREA 6 - PHASE 1
FA107B AREA CEILING PLAN - FIRST FLOOR - AREA 7 - PHASE 1
FA108B AREA CEILING PLAN - FIRST FLOOR - AREA 8 - PHASE 1
FA109B AREA CEILING PLAN - FIRST FLOOR - AREA 9 - PHASE 1
FA110B AREA CEILING PLAN - FIRST FLOOR - AREA 10 - PHASE 1
FA111B AREA CEILING PLAN - FIRST FLOOR - AREA 11 - PHASE 1
FA112B AREA CEILING PLAN - FIRST FLOOR - AREA 12 - PHASE 1
FA100C OVERALL SECOND FLOOR PLAN - SECOND FLOOR - PHASE 1
FA101C AREA CEILING PLAN - SECOND FLOOR - AREA 1 - PHASE 1
FA102C AREA CEILING PLAN - SECOND FLOOR - AREA 2 - PHASE 1
FA103C AREA CEILING PLAN - SECOND FLOOR - AREA 3 - PHASE 1
FA104C AREA CEILING PLAN - SECOND FLOOR - AREA 4 - PHASE 1
FA105C AREA CEILING PLAN - SECOND FLOOR - AREA 5 - PHASE 1
FA106C AREA CEILING PLAN - SECOND FLOOR - AREA 6 - PHASE 1
FA107C AREA CEILING PLAN - SECOND FLOOR - AREA 7 - PHASE 1
FA108C AREA CEILING PLAN - SECOND FLOOR - AREA 8 - PHASE 1
FA109C AREA CEILING PLAN - SECOND FLOOR - AREA 9 - PHASE 1
FA110C AREA CEILING PLAN - SECOND FLOOR - AREA 10 - PHASE 1
FA111C AREA CEILING PLAN - SECOND FLOOR - AREA 11 - PHASE 1
FA112C AREA CEILING PLAN - SECOND FLOOR - AREA 12 - PHASE 1
FA500 FIRE ALARM AND MASS NOTIFICATION DETAILS - PHASE 1
FA501 FIRE ALARM AND MASS NOTIFICATION DETAILS - PHASE 1
FA502 FIRE ALARM AND MASS NOTIFICATION MATRIX OF OPERATIONS - PHASE 1 -
FX001 FIRE SUPPRESSION GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS -
PHASE 1 -
FXD100A OVERALL BASEMENT DEMOLITION PLAN - BASEMENT - PHASE 1
FXD101A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 1 -PHASE 1
FXD102A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 2 - PHASE 1
FXD103A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 3 - PHASE 1
FXD104A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 4 - PHASE 1
FXD105A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 5 - PHASE 1
FXD106A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 6 - PHASE 1
FXD107A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 7 - PHASE 1
FXD108A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 8 - PHASE 1
FXD109A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 9 - PHASE 1
FXD110A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 10 - PHASE 1
FXD111A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 11 - PHASE 1
FXD112A AREA DEMOLITION CEILING PLAN - BASEMENT - AREA 12 -PHASE 1
FXD100B OVERALL FIRST FLOOR DEMOLITION PLAN - FIRST FLOOR - PACKAGE A
FXD101B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 1 - PHASE 1
FXD102B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 2 - PHASE 1
FXD103B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 3 - PHASE 1
FXD104B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 4 - PHASE 1
FXD105B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 5 - PHASE 1
FXD106B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 6 - PHASE 1
FXD107B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 7 - PHASE 1
FXD108B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 8 - PHASE 1
FXD109B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 9 - PHASE 1
FXD110B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 10 - PHASE 1
FXD111B AREA DEMOLITION CEILING PLAN - FIRST FLOOR - AREA 11 - PHASE 1
FIRE PROTECTION SHEET INDEXGENERAL SHEET INDEX
G004 VOLUME 4 - PHASE 1 COVER SHEET - FIRE PROTECTION
G012 VOLUME 4 - PHASE 1 SHEET INDEX - FIRE PROTECTION
W
2Q R
R
_P la ns _P
H 1_
Vo l4
-0
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
10" ELECTRIC BELL
OMNI-DIRECTIONAL FIRE ALARM ANTENNA
"WP"
GENERAL NOTES AND SYMBOLS
XX, C
FIRE ALARM AND MASS NOTIFICATION HORN/STROBE
(XX DENOTES MINIMUM CANDELA RATING)
(C DENOTES CEILING MOUNTED)XX, C
FIRE ALARM AND MASS NOTIFICATION SYMBOLS
FIRE ALARM AND MASS NOTIFICATION STROBE
(XX DENOTES MINIMUM CANDELA RATING)
(C DENOTES CEILING MOUNTED)
FMCP
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)
LCD ANNUNCIATOR PANEL
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
THE FIRE ALARM/MASS NOTIFICATION SYSTEM MUST BE DESIGNED, INSTALLED, AND
COMMISSIONED IN ACCORDANCE WITH THE FOLLOW ING:
- NFPA 72 (2019 EDITION)
- UFC 3-600-01 (CHANGE 4, FEBRUARY 2020)
- UFC 4-010-01 (DECEMBER 2018)
- UFC 4-021-01 (CHANGE 1, JANUARY 2010)
- ECB 2018-17
NOTE: SEE SHEET E001 FOR APPLICABLE ELECTRICAL CODES AND
REGULATIONS
THESE DOCUMENTS DEPICT A PERFORMANCE LEVEL ENGINEERING DESIGN
LAYOUT TO BE UTILIZED AS GUIDANCE FOR THE PLANNING OF THE SYSTEM BY THE
CONTRACTOR. PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL
FROM THE ENGINEER OF RECORD AND THE AUTHORITY HAVING JURISDICTION
PRIOR TO INSTALLATION. INCLUDE IN THE SHOP DRAWINGS AND CALCULATIONS
ANY ADDITIONAL EQUIPMENT NECESSARY, INCLUDING INITIATING DEVICES AND
NOTIFICATION APPLIANCES, TO PROVIDE A COMPLETE INSTALLATION AND COMPLY
WITH LOCAL CODES, AMENDMENTS AND BASE STANDARDS.
FOR COMPLETE SYSTEM CONTROL, REFER TO THE MATRIX OF OPERATIONS WITHIN
THIS PHASE.
PROVIDE AN ADDRESSABLE FIRE ALARM/MASS NOTIFICATION SYSTEM CONTROL
PANEL. SYSTEM MUST BE NETWORKED INTO THE EXISTING SIMPLEX MODEL 4100
FMCP CURRENTLY IN THE BUILDING AND THE EXISTING BASEWIDE FIRE ALARM
SYSTEM NETWORK.
THE FLASH RATE OF VISIBLE NOTIFICATION APPLIANCES MUST NOT EXCEED 2
FLASHES PER SECOND, NOR BE LESS THAN 1 FLASH EVERY SECOND, IN
ACCORDANCE WITH NFPA 72. A MAXIMUM PULSE DURATION MUST BE 0.2 SECONDS
WITH A MAXIMUM DUTY CYCLE OF 40%, IN ACCORDANCE W ITH NFPA 72. VISIBLE
NOTIFICATION APPLIANCES MUST BE SPACED IN ACCORDANCE WITH NFPA 72.
STROBES MUST BE SYNCHRONIZED.
AUDIBLE FIRE ALARM SOUND LEVELS MUST BE AT LEAST 15 dBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 dBA ABOVE THE MAXIMUM SOUND LEVEL
HAVING A DURATION OF AT LEAST 60 SECONDS, WHICHEVER IS GREATER,
MEASURED 5 FEET ABOVE THE FLOOR IN THE OCCUPIABLE AREA, BUT NOT
GREATER THAN 120 dBA AT THE MINIMUM HEARING DISTANCE FROM THE AUDILE
APPLIANCE.
PROVIDE ADEQUATE NOTIFICATION APPLIANCES THROUGHOUT THE FACILITY TO
MEET THE UFC 3-600-01 REQUIREMENTS.
SPRINKLER SYSTEM TAMPER AND FLOW SWITCHES MUST BE INSTALLED UNDER
SPECIFICATION SECTION 21 13 13.00 10. CONNECT DEVICES TO THE FIRE ALARM
SIGNALING LINE CIRCUITS.
OBTAIN APPROVALS FROM THE FPDOR AND AHJ PRIOR TO COMMENCING WORK.
DO NOT LOCATE DETECTORS IN DIRECT AIR OR CLOSER THAN 3 FEET FROM AN AIR
SUPPLY OR RETURN DIFFUSER.
MOUNT ALL WALL-MOUNTED VISUAL AND VISUAL/AUDIBLE NOTIFICATION
APPLIANCES WITH THE ENTIRE STROBE LENS BETWEEN 80" TO 96" ABOVE THE
FINISHED FLOOR.
FIRE ALARM SIGNALING LINE CIRCUITS (SLC) AND NOTIFICATION APPLIANCE
CIRCUITS (NAC) ARE TO BE CLASS B. T-TAPS, WIRE NUTS, AND/OR PIG TAILS ARE
NOT PERMITTED.
THE CONTRACTOR MUST SPACE SPEAKERS TO PROVIDE A COMMON
INTELLIGIBILITY SCALE (CIS) SCORE THAT MEETS THE MINIMUM INTENT OF UFC
4-021-01. THE INSTALLING CONTRACTOR MUST VERIFY THEIR DESIGN MEETS THIS
INTENT BY PROVIDING SPEECH INTELLIGIBILITY CALCULATIONS BASED ON THE
INSTALLED PRODUCTS' THEORETICAL Q AND DIRECTIVITY INDEX. TO CONFIRM
INTELLGIBILITY, SPEAKERS MUST TESTED AND ADDED TO MEET REQUIREMENTS.
SPEAKERS MUST NOT BE LOCATED ADJACENT TO LOCS. MINIMUM CIS VALUE IN
EACH AREA WHERE OCCUPANTS ARE TYPICALLY LOCATED IS 0.8.
FIRE ALARM ZONES MUST COINCIDE WITH FIRE SPRINKLER ZONES.
QUALIFIED FIRE PROTECTION ENGINEER (QFPE) MUST REVIEW DOCUMENTS AND
SHOP DRAWINGS MUST BEAR THE REVIEW STAMP OF THE QFPE PRIOR TO
SUBMITTING TO THE DESIGNATED FIRE PROTECTION ENGINEER (DFPE).
SYSTEM SHUTDOWNS MUST BE KEPT TO A MINIMUM AND ARE TO OCCUR AFTER
NORMAL BUSINESS HOURS. RECONFIGURATION OF EXISTING CIRCUITS AND WIRING
MUST BE ACCOMPLISHED BY INSTALLING ALL NEW CIRCUITS AND WIRING PRIOR TO
THE FINAL CONNECTIONS. SHUTDOWNS OF THE FIRE ALARM SYSTEMS WILL ONLY
BE ALLOWED ONCE THE NEW CIRCUITS AND WIRING IS READY IN ALL RESPECTS
FOR FINAL CONNECTIONS.
DEACTIVATION, RELOCATION, AND NEW WORK MUST BE PLANNED TO MINIMIZE
DISRUPTION OF BASE OFFICE FUNCTIONS. PROVIDE TEMPORARY CAPPING AND
CONNECTIONS AS REQUIRED TO MAINTAIN EXISTING SYSTEMS DURING
CONSTRUCTION. COORDINATE ALL SHUTDOWNS WITH CONTRACTING OFFICER
GROUP.
THE CONTRACTOR MUST PROVIDE A FIRE W ATCH PATROL IN COMPLIANCE WITH
WRIGHT PATTERSON AFB 32-2001 WITH ASSOCIATED ATTACHMENTS, UFC 3-601-02,
NFPA 1 AND NFPA 241 FOR ALL AREAS DURING ALL TIMES WHENEVER THE FIRE
ALARM SYSTEM OR FIRE SPRINKLER SYSTEMS IN THE OCCUPIED AREAS OF THE
BUILDING ARE INOPERABLE. THE CONTRACTOR MUST ALSO PROVIDE A FIRE
WATCH PATROL FOR CONSTRUCTION AREAS AT ALL TIMES WHEN CONSTRUCTION
AND DEMOLITION OPERATIONS ARE NOT IN PROGRESS. WP AFB FIRE PREVENTION
MUST BE NOTIFIED BY THE CONTRACTOR ANY TIME A FIRE PROTECTION/DETECTION
SYSTEM OR LIFE SAFETY COMPONENT IS IMPAIRED. FIRE WATCH PATROL GUARDS
MUST PATROL ALL PARTS OF THE BUILDING, AND OUTSIDE AREAS WHERE
HAZARDOUS EQUIPMENT OR MATERIALS ARE LOCATED. ROUNDS MUST BE
CONDUCTED EVERY ½-HOUR FOR 2-HOURS AFTER SUSPENSION OF WORK FOR THE
DAY AND EVERY HOUR THEREAFTER DURING NONWORKING HOURS AND MUST
INCLUDE TOURS OF ACCESSIBLE WORK AREAS. THE CONTRACTOR MUST
COORDINATE WITH THE BUILDING MANAGEMENT TO ARRANGE FOR SIMILAR FIRE
WATCH PATROLS FOR SECURED AND CLASSIFIED AREAS WHICH ARE NOT
ACCESSIBLE TO THE CONTRACTOR. FIRE WATCH PERSONNEL MUST BE TRAINED IN
THE FOLLOWING, NOTIFICATION PROCEDURES THAT INCLUDE CALLING THE FIRE
DEPARTMENT AND MANAGEMENT PERSONNEL, FUNCTION AND OPERATION OF FIRE
PROTECTION EQUIPMENT, FAMILIARIZATION WITH FIRE HAZARDS, AND USE OF
CONSTRUCTION ELEVATORS, WHERE PROVIDED.
UL LISTED FIRE ALARM AND MASS NOTIFICATION CONTROL PANEL
VISUAL TEXT DISPLAY
ANN
VTD
MM ADDRESSABLE MONITOR MODULE
SMOKE DETECTOR (P - PHOTOELECTRIC, E - ELEVATOR)
NOTIFICATION APPLIANCE CIRCUIT REMOTE POWER SUPPLYNAC
ADDRESSABLE CONTROL MODULE
F DOUBLE ACTION MANUAL FIRE ALARM PULL STATION
CM
DUCT SMOKE DETECTOR (S - SUPPLY; R - RETURN)
S, R
FIRE ALARM AND MASS NOTIFICATION SPEAKER
(WP DENOTES WEATHER PROOF)
(C DENOTES CEILING MOUNTED)
MISCELLANEOUS
FIRE ALARM AND MASS NOTIFICATION NOTES
SS SURGE SUPPRESSOR
DESIGNATES WEATHERPROOF BACKBOX AND DEVICE
HEAT DETECTOR
(XX DENOTES TEMPERATURE RATING IN FARENHEIT)
(WP DENOTES WEATHERPROOF)
H
NOTE: HALFTONED COLORING DENOTES DEVICES TO BE DEMOLISHED.
WALL MOUNTED OPTICAL FLAME DETECTOR - INFRARED
P PRESSURE SWITCH WITH ADDRESSABLE MONITOR MODULE
SUPERVISORY VALVE TAMPER SWITCH WITH ADDRESSABLE MONITOR MODULE
WATER FLOW SWITCH WITH ADDRESSABLE MONITOR MODULE
CARBON MONOXIDE DETECTOR
FIRE ALARM AND MASS NOTIFICATION SPEAKER/STROBE
(XX DENOTES MINIMUM CANDELA RATING)
(C DENOTES CEILING MOUNTED)XX, C
DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS, NOTIFICATION APPLIANCES, CONDUIT, CIRCUITS, AND INTERFACE MODULES WITHIN THE SELECTIVE PHASE UNLESS OTHERWISE INDICATED. FULL-TONE SYMBOLS REPRESENT EXISTING DEVICES BEING DEMOLISHED IN THE PHASE. SIGNALING LINE AND NOTIFICATION APPLIANCE CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY. FIRE ALARM EQUIPMENT, PANELS THAT POWER THE FIRE ALARM EQUIPMENT, AND CONDUIT NOT
WITHIN THE PHASE 1 AREA OF WORK MUST REMAIN FULLY OPERATIONAL DURING PHASE 1.
MATERIALS FROM THE DEMOLITION WORK FOR THE EXISTING FIRE ALARM SYSTEM MUST BE REMOVED FROM SITE (UNLESS NOTED OTHERWISE) AND DISPOSED OF IN ACCORDANCE WITH THE APPLICABLE ENVIRONMENTAL PROTECTION AGENCY AND STATE CODES, REGULATIONS AND AS DIRECTED BY COTR. CLEAN-UP MUST BE DAILY OR
AS DIRECTED BY COTR.
EXISTING W ALL PENETRATIONS THAT ARE NOT REUSED MUST BE REPAIRED TO MATCH EXISTING BUILDING FINISHES. FIRE STOPPED PENETRATIONS WHERE EXISTING CONDUIT MUST BE REMOVED AND MUST BE REPAIRED
TO MAINTAIN BUILDING FIRE INTEGRITY.
CONTRACTOR MUST DEMOLISH ALL ABANDONED IN PLACE FIRE ALARM EQUIPMENT FROM THE BUILDING WITHIN THE
SCOPE AREA.
FIRE ALARM AND MASS NOTIFICATION DEMOLITION NOTES
A.
B.
C.
D.
GAP GRAPHIC ANNUNCIATOR PANEL
WP, C
P, E
CO
RAT RADIO ALARM TRANSMITTER
WF
C
TS
C
ASSD AIR SAMPLING SMOKE DETECTOR PANEL
NOTIFICATION APPLIANCE REQUIREMENTS TABLE
IM ISOLATION MODULE
C FIRE ALARM/MASS NOTIFICATION PANEL DOCUMENTS CABINET
DH DOOR HOLDER
FACP UL LISTED FIRE ALARM CONTROL PANEL
LOC RADIO ALARM TRANSMITTER
ABBREVIATIONS
ACU
AFF
AHJ
AVG
CO
COTR
ELEV
EOL
FPC
FPDOR
LOC
MIN
NAC
NIC
NP
NC
QFPE
SLC
SQFT
VEWFD
WP
AUTONOMOUS CONTROL UNIT
ABOVE FINISHED FLOOR
AUTHORITY HAVING JURISDICTION
AVERAGE
CONTRACTING OFFICER
CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE
ELEVATION
END OF LINE RESISTOR
FIRE PUMP CONTROLLER
FIRE PROTECTION DESIGNER OF RECORD
LOCAL OPERATING CONSOLE
MINIMUM
NOTIFICATION APPLIANCE CIRCUIT
NOT IN CONTRACT
NOT PERMITTED
NONCOMBUSTIBLE
QUALIFIED FIRE PROTECTION ENGINEER
SIGNALING LINE CIRCUIT
SQUARE FEET
VERY EARLY WARNING FIRE DETECTION
WEATHER PROOF
POINT OF NEW CONNECTION TO EXISTING PIPING
POINT OF DISCONNECTION
2-HOUR FIRE RATED CONSTRUCTION BARRIER
REMOVE 2-HOUR CONSTRUCTION BARRIER
FIRE ALARM ZONE BOUNDARY LINE
CONCRETE MASONRY UNIT
PHASE BOUNDARY LINE
INSTALL TERMINAL CABINETS, JUNCTION BOXES, CONDUIT, WIRING ETC. TO ALLOW FOR
TRANSFER OF CIRCUITS FROM PRESENT MAIN FIRE ALARM CONTROL PANEL (FACP) TO
LOCATION WHERE MAIN FACP WILL BE REINSTALLED.
MODIFY EXISTING CIRCUITS THAT CROSS THE CONSTRUCTION BARRIERS ON THE NORTH SIDE
OF FIRST FLOOR, THE MAIN ELECTRICAL ROOM AND A-SWITCH ROOM IN THE BASEMENT AND
THE OFFICE SPACES ON FIRST ANDSECOND FLOOR. THE INTENT IS TO MAINTAIN THE
OPERATION OF THESE CIRCUITS AND FIRE ALARM SYSTEMS FOR THE OCCUPIED NON-
CONSTRUCTION SIDE OF THE CONSTRUCTION BARRIER. MAINTAIN MANUAL PULL STATIONS
AND CIRCUITS AT THE ENTRANCES TO STAIRS, 4 AND 6 ON FIRST AND SECOND FLOOR AND THE
EXITS FROM THE OFFICES.
DEMOLISH FIRE ALARM DEVICES, CONDUIT, WIRING, ETC. IN THESE SAME AREAS.
ADD, RELOCATE, DEMOLISH EXISTING DEVICES IN OTHER AREAS OF CONSTRUCTION TO
MAINTAIN EQUIVALENT LEVELS OF FIRE ALARM COVERAGE.
RELOCATE THE MAIN FACP OUTSIDE OF THE CONSTRUCTION BARRIER OF THE OFFICES ON THE
FIRST FLOOR. MAINTAIN FULL OPERATION OF THE FACP WITH MINIMAL DISRUPTION. PROVIDE
FIRE WATCH AS INDICATED IN THE DESIGN DOCUMENTS.
INSTALL NEW MAIN FACP ON THE FIRST FLOOR OFFICES AS INDICATED IN THE DESIGN
DOCUMENTS. INSTALL NEW CIRCUITS, CONDUIT, WIRING, ETC. AND INSTALL NEW NOTIFICATION
APPLIANCES AND INITIATION DEVICES FOR THE RENOVATED AREAS OF THE NORTH SIDE OF
THE FIRST FLOOR, THE MAIN ELECTRICAL ROOM, A-SW ITCH ROOM AND FIRE PUMP ROOM IN
THE BASEMENT AND THE FIRST AND SECOND FLOOR OFFICES.
INTERFACE THE ORIGINAL FACP WITH THE NEW FACP FOR MUTUAL NOTIFICATION OF ALARM
SIGNALS. CONNECT THE NEW FACP TO THE BASE REPORTING SYSTEM.
SEQUENCING INFORMATION
A.
B.
C.
D.
E.
F.
G.
XX, WP
K KNOX BOX
ROOM TYPE VISUAL NOTIFICATION
REQUIRED
INTELLIGIBILITY
REQUIRED
DESIGN AMBIENT
SOUND LEVEL
OPEN OFFICE Y Y 69
PRIVATE OFFICE/RECEIVING OFFICE Y Y 69
ELECTRICAL/A-SWITCH TELCO RACKS Y Y 45
VESTIBULE Y Y 69
FIRE PUMP Y Y 45
REFERENCES:
- UFC 3-600-01 (9-18.6.3) FOR VISUAL NOTIFICATION REQUIREMENTS
- UFC 4-021-01 (4-6.1.2) FOR INTELLIGIBILITY REQUIREMENTS
- NFPA 72 (18.4.11.3) FOR DESIGN SOUND AMBIENT LEVEL
STAIRS/ELEVATOR SHAFTS/CHASES N N N/A
PLUMBING EQUIPMENT Y Y 45
MEN/WOMEN RESTROOM Y Y 69
CUSTODIAL N Y 45
STORAGE Y Y 45
RECEPTION/WAITING Y Y 69
CORRIDOR Y Y 69
COLLABORATION Y Y 75
TELECOMMUNICATIONS Y Y 45
CONFERENCE ROOM Y Y 75
COPY/COFFEE Y Y 75
NURSING Y Y 69
FOOD VENUE Y Y 75
UNISEX/LOCKERS Y Y 69
WASTE & RECYCLING Y Y 45
BARBER SHOP Y Y 69
GOODWILL Y Y 55
STAGING Y Y 45
DINING Y Y 75
LOBBY/GUARD DESK Y Y 69
CREDIT UNION Y Y 69
DRY CLEANER Y Y 69
NORTH BRIDGE Y Y 69
EXPRESS/CIRCULATION Y Y 75
NOTE: IF ROOM IS NOT IN ABOVE LIST, USE THE BELOW CODES AND STANDARDS TO DETERMINE THE VISUAL NOTIFICATION REQUIREMENTS, INTELLIGIBILITY REQUIREMENTS, AND THE DESIGN SOUND AMBIENT LEVEL.
NOTE: SPEAKERS MUST NOT BE LOCATED ADJACENT TO LOC'S. SEE UFC 4-021-01 FOR LOC REQUIREMENTS.
NOTE: PROVIDE WEATHERPROOF SPEAKERS AT EVERY EXIT DOOR IN ACCORDANCE WITH UFC 4-021-01.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
FA001
FI
R
E
AL
AR
M
A N
D M
AS
S
N O
TI
FI
C
AT
IO
N
G
EN
ER
AL
N O
TE
S, SY
M
BO
LS
, A N
D A
BB
R
EV
IA
TI
O
N S
-P H
AS
E
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
N . B
R O
AD
W
AY
S
T.
L
O U
IS
, M
O . 6
J.
A.
B
EA
LS
S.
S.
R O
D R
IG
U
EZ
C .W
. K R
IE
BE
L
O
C
TO
BE
R
W
2Q R
R
XX
XX
B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION
W
2Q R
R
_P la ns _P
H 1_
Vo l4
-0
T
S
R
Q
P
O
N
M
L
K
J
I
H
G
F
E
D
C
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 19 20 21 22 23 24 2517 23E22E
1-J
1-17
1-16
1-15
1-14
1-13.5
1-13
1-12
BUILDING NOT IN SCOPE
B
1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION
GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS.
NOTE: SHADED AREA IS NOT UNDER CURRENT CONSTRUCTION PHASE
UNLESS NOTED OTHERWISE - WORK TO BE PERFORMED IN THE
SHADED AREAS MUST BE COORDINATED WITH COR FOUR WEEKS
PRIOR TO MINIMIZE MISSION IMPACT.
GENERAL NOTES - DEMOLITION KEYED NOTES - DEMOLITION
1. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES
WITHIN THE AREA OF WORK AS NECESSARY TO ACCOMMODATE
NEW LAYOUT.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
FAD100A
O
VE
R
AL
L
BA
SE
M
EN
T
D
EM
O
LI
TI
O
N P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
N . B
R O
AD
W
AY
S
T.
L
O U
IS
, M
O . 6
J.
A.
B
EA
LS
S.
S.
R O
D R
IG
U
EZ
C .W
. K R
IE
BE
L
O
C
TO
BE
R
W
2Q R
R
XX
XX
B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION
BA
SE
M
EN
T -P
H
AS
E
FI
R
E P
R O
TE
C
TI
O
N D
EM
O
LI
TI
O N
1/32" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION OVERALL BASEMENT DEMOLITION PLAN N
0 32'16' 64'
W
2Q R
R
_P la ns _P
H 1_
Vo l4
-0
M
G
F
E
D
C
A
18 19 20 21 22 23 24 2523E22E
MA
TC
HL
IN
E
A1
FA
D1
A
MATCHLINE
A1 FAD102A
WF
C
TS
C
(2
A-SW ITCH TELCO RACKS
ELECTRICAL
B
1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL
NOTES, SYMBOLS, AMD ABBREVIATIONS.
2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,
NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED
CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED
ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE
CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE
THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.
3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT
MANAGER AND THE WRITTEN APPROVAL OF USACE.
4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND
NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE
FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.
THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.
5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING
CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR
GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING
CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE
FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO
FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE
DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE
CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN
WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.
COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND
REMOTE PANELS WITH TECHNICIAN.
NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT
EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT
UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -
WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED
WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.
GENERAL NOTES - DEMOLITION W ORK
1. EXISTING MONITOR MODULES, TAMPER SWITCH, AND FLOW SWITCH TO BE
DEMOLISHED.
2. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES WITHIN
THE AREA OF WORK AS NESCESSARY TO ACCOMMODATE NEW LAYOUT.
KEYED NOTES - DEMOLITION W ORK
KEY PLAN
N
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
8'4' 16'
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
FAD101A
AR
EA
D
EM
O
LI
TI
O
N C
EI
LI
N G
P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
N . B
R O
AD
W
AY
S
T.
L
O U
IS
, M
O . 6
J.
A.
B
EA
LS
S.
S.
R O
D R
IG
U
EZ
C .W
. K R
IE
BE
L
O
C
TO
BE
R
W
2Q R
R
XX
XX
B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION
BA
SE
M
EN
T -A
R
EA
P H
AS
E
FI
R
E P
R O
TE
C
TI
O
N D
EM
O
LI
TI
O N
1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 1
W
2Q R
R
_P la ns _P
H 1_
Vo l4
-0
L
I
H
G
18 19 20 21 22 23 24 2523E22E
MATCHLINE
A1 FAD101A
MATCHLINE
A1 FAD103A
MA
TC
HL
IN
E
A1
FA
D1
A
TS
C
WF
C
(6)
(3)
CORRIDOR
WHITE SPACE
1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL
NOTES, SYMBOLS, AMD ABBREVIATIONS.
2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,
NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED
CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED
ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE
CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE
THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.
3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT
MANAGER AND THE WRITTEN APPROVAL OF USACE.
4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND
NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE
FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.
THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.
5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING
CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR
GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING
CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE
FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO
FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE
DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE
CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN
WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.
COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND
REMOTE PANELS WITH TECHNICIAN.
NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT
EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT
UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -
WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED
WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.
GENERAL NOTES - DEMOLITION W ORK
1. EXISTING TAMPER SWITCHES AND FLOW SWITCHES TO BE DEMOLISHED.
2. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES WITHIN
THE AREA OF WORK AS NESCESSARY TO ACCOMMODATE NEW LAYOUT.
3. UNOCCUPIED MECHANICAL AREA.
KEYED NOTES - DEMOLITION W ORK
KEY PLAN
N
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
8'4' 16'
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
FAD102A
AR
EA
D
EM
O
LI
TI
O
N C
EI
LI
N G
P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
N . B
R O
AD
W
AY
S
T.
L
O U
IS
, M
O . 6
J.
A.
B
EA
LS
S.
S.
R O
D R
IG
U
EZ
C .W
. K R
IE
BE
L
O
C
TO
BE
R
W
2Q R
R
XX
XX
B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION
BA
SE
M
EN
T -A
R
EA
P H
AS
E
FI
R
E P
R O
TE
C
TI
O
N D
EM
O
LI
TI
O N
1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 2
W
2Q R
R
_P la ns _P
H 1_
Vo l4
-0
T
S
R
Q
P
O
N
18 19 20 21 22 23 24 2523E22E
MATCHLINE
A1 FAD102A
MA
TC
HL
IN
E
A1
FA
D1
A
WF
C
TS
C
(2
1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL
NOTES, SYMBOLS, AMD ABBREVIATIONS.
2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,
NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED
CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED
ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE
CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE
THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.
3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT
MANAGER AND THE WRITTEN APPROVAL OF USACE.
4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND
NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE
FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.
THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.
5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING
CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR
GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING
CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE
FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO
FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE
DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE
CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN
WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.
COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND
REMOTE PANELS WITH TECHNICIAN.
NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT
EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT
UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -
WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED
WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.
GENERAL NOTES - DEMOLITION W ORK
1. EXISTING MONITOR MODULES, TAMPER SWITCH, AND FLOW SWITCH TO BE
DEMOLISHED.
2. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES WITHIN
THE AREA OF WORK AS NESCESSARY TO ACCOMMODATE NEW LAYOUT.
3. UNOCCUPIED MECHANICAL AREA.
KEYED NOTES - DEMOLITION W ORK
KEY PLAN
N
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
8'4' 16'
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
FAD103A
AR
EA
D
EM
O
LI
TI
O
N C
EI
LI
N G
P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
N . B
R O
AD
W
AY
S
T.
L
O U
IS
, M
O . 6
J.
A.
B
EA
LS
S.
S.
R O
D R
IG
U
EZ
C .W
. K R
IE
BE
L
O
C
TO
BE
R
W
2Q R
R
XX
XX
B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION
BA
SE
M
EN
T -A
R
EA
P H
AS
E
FI
R
E P
R O
TE
C
TI
O
N D
EM
O
LI
TI
O N
1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 3
W
2Q R
R
_P la ns _P
H 1_
Vo l4
-0
G
F
E
D
C
A
11 12 13 14 15 16 18 1917
MA
TC
HL
IN
E
A1
FA
D1
A
MA
TC
HL
IN
E
A1
FA
D1
A
MATCHLINE
A1 FAD105A
WF
C
TS
C
(2
STAIR 8
EXIT PASSAGE
PLUMBING EQUIPMENT
MAIN ELECTRICAL
ELECTRICAL
UTILITY
UTILITY
1. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES WITHIN
THE AREA OF WORK AS NESCESSARY TO ACCOMMODATE NEW LAYOUT.
B
1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL
NOTES, SYMBOLS, AMD ABBREVIATIONS.
2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,
NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED
CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED
ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE
CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE
THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.
3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT
MANAGER AND THE WRITTEN APPROVAL OF USACE.
4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND
NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE
FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.
THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.
5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING
CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR
GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING
CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE
FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO
FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE
DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE
CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN
WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.
COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND
REMOTE PANELS WITH TECHNICIAN.
NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT
EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT
UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -
WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED
WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.
GENERAL NOTES - DEMOLITION W ORK
KEYED NOTES - DEMOLITION W ORK
KEY PLAN
N
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
8'4' 16'
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
FAD104A
AR
EA
D
EM
O
LI
TI
O
N C
EI
LI
N G
P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
N . B
R O
AD
W
AY
S
T.
L
O U
IS
, M
O . 6
J.
A.
B
EA
LS
S.
S.
R O
D R
IG
U
EZ
C .W
. K R
IE
BE
L
O
C
TO
BE
R
W
2Q R
R
XX
XX
B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION
BA
SE
M
EN
T -A
R
EA
P H
AS
E
FI
R
E P
R O
TE
C
TI
O
N D
EM
O
LI
TI
O N
1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 4
W
2Q R
R
_P la ns _P
H 1_
Vo l4
-0
K
J
I
H
G
11 12 13 14 15 16 18 1917
MA
TC
HL
IN
E
A1
FA
D1
A
MATCHLINE
A1 FAD104A
MA
TC
HL
IN
E
A1
FA
D1
A
MATCHLINE
A1 FAD106A
1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL
NOTES, SYMBOLS, AMD ABBREVIATIONS.
2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,
NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED
CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED
ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE
CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE
THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.
3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT
MANAGER AND THE WRITTEN APPROVAL OF USACE.
4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND
NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE
FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.
THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.
5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING
CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR
GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING
CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE
FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO
FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE
DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE
CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN
WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.
COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND
REMOTE PANELS WITH TECHNICIAN.
NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT
EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT
UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -
WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED
WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.
GENERAL NOTES - DEMOLITION W ORK
1. NO ANTICIPATED WORK IN THIS AREA.
KEYED NOTES - DEMOLITION W ORK
KEY PLAN
N
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
8'4' 16'
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
FAD105A
AR
EA
D
EM
O
LI
TI
O
N C
EI
LI
N G
P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
N . B
R O
AD
W
AY
S
T.
L
O U
IS
, M
O . 6
J.
A.
B
EA
LS
S.
S.
R O
D R
IG
U
EZ
C .W
. K R
IE
BE
L
O
C
TO
BE
R
W
2Q R
R
XX
XX
B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION
BA
SE
M
EN
T -A
R
EA
P H
AS
E
FI
R
E P
R O
TE
C
TI
O
N D
EM
O
LI
TI
O N
1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 5
W
2Q R
R
_P la ns _P
H 1_
Vo l4
-0
F
M
T
S
R
Q
P
O
N
11 12 13 14 15 16 18 1917
MATCHLINE
A1 FAD105A
MA
TC
HL
IN
E
A1
FA
D1
A
MA
TC
HL
IN
E
A1
FA
D1
A
TS
C
WF
C
(2
1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL
NOTES, SYMBOLS, AMD ABBREVIATIONS.
2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,
NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED
CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED
ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE
CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE
THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.
3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT
MANAGER AND THE WRITTEN APPROVAL OF USACE.
4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND
NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE
FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.
THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.
5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING
CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR
GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING
CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE
FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO
FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE
DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE
CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN
WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.
COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND
REMOTE PANELS WITH TECHNICIAN.
NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT
EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT
UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -
WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED
WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.
GENERAL NOTES - DEMOLITION W ORK
KEYED NOTES - DEMOLITION W ORK
1. NO ANTICIPATED WORK IN THIS AREA.
2. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES WITHIN
THE AREA OF WORK AS NESCESSARY TO ACCOMMODATE NEW LAYOUT.
KEY PLAN
N
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
8'4' 16'
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
FAD106A
AR
EA
D
EM
O
LI
TI
O
N C
EI
LI
N G
P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
N . B
R O
AD
W
AY
S
T.
L
O U
IS
, M
O . 6
J.
A.
B
EA
LS
S.
S.
R O
D R
IG
U
EZ
C .W
. K R
IE
BE
L
O
C
TO
BE
R
W
2Q R
R
XX
XX
B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION
BA
SE
M
EN
T -A
R
EA
P H
AS
E
FI
R
E P
R O
TE
C
TI
O
N D
EM
O
LI
TI
O N
1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 6
W
2Q R
R
_P la ns _P
H 1_
Vo l4
-0
G
4 5 6 7 8 9 10 11 12
MA
TC
HL
IN
E
A1
FA
D1
A
MA
TC
HL
IN
E
A1
FA
D1
A
MATCHLINE
A1 FAD108A
TS
C
WF
C
(2
B
1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL
NOTES, SYMBOLS, AMD ABBREVIATIONS.
2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,
NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED
CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED
ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE
CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE
THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.
3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT
MANAGER AND THE WRITTEN APPROVAL OF USACE.
4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND
NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE
FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.
THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.
5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING
CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR
GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING
CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE
FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO
FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE
DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE
CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN
WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.
COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND
REMOTE PANELS WITH TECHNICIAN.
NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT
EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT
UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -
WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED
WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.
GENERAL NOTES - DEMOLITION W ORK
KEYED NOTES - DEMOLITION W ORK
1. MODIFY EXISTING SYSTEMS FIRE ALARM CIRCUITS AND APPLIANCES WITHIN
THE AREA OF WORK AS NESCESSARY TO ACCOMMODATE NEW LAYOUT.
2. UNOCCUPIED MECHANICAL AREA.
KEY PLAN
N
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
8'4' 16'
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
FAD107A
AR
EA
D
EM
O
LI
TI
O
N C
EI
LI
N G
P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
N . B
R O
AD
W
AY
S
T.
L
O U
IS
, M
O . 6
J.
A.
B
EA
LS
S.
S.
R O
D R
IG
U
EZ
C .W
. K R
IE
BE
L
O
C
TO
BE
R
W
2Q R
R
XX
XX
B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION
BA
SE
M
EN
T -A
R
EA
P H
AS
E
FI
R
E P
R O
TE
C
TI
O
N D
EM
O
LI
TI
O N
1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 7
W
2Q R
R
_P la ns _P
H 1_
Vo l4
-0
K
J
I
H
G
4 5 6 7 8 9 10 11 12
MATCHLINE
A1 FAD107A
MA
TC
HL
IN
E
A1
FA
D1
A
MA
TC
HL
IN
E
A1
FA
D1
A
MATCHLINE
A1 FAD109A
1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL
NOTES, SYMBOLS, AMD ABBREVIATIONS.
2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,
NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED
CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED
ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE
CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE
THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.
3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT
MANAGER AND THE WRITTEN APPROVAL OF USACE.
4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND
NOTIFICATION APPLIANCE CIRCUITS TO THE OCCUPIED AREAS OF THE
FACILITY. REVISE CIRCUIT/CONDUIT LAYOUT AS NEEDED TO PERFORM WORK.
THE USE OF T-TAPS, WIRE NUTS, AND/OR PIG TAILS IS PROHIBITED.
5. INFORMATION SHOWN ON THIS DRAWING PERTAINING TO EXISTING
CONDITIONS HAS BEEN OBTAINED FROM AVAILABLE BUILDING DRAWINGS OR
GENERAL FIELD OBSERVATIONS AND MAY NOT INDICATE ACTUAL EXISTING
CONDITIONS IN DETAIL OR DIMENSION. THE CONTRACTOR IS RESPONSIBLE
FOR DETERMINING THE ACTUAL EXISTING CONDITIONS PRIOR TO
FABRICATION OR PERFORMANCE OF ANY WORK. SHOULD CONDITIONS BE
DISCOVERED THAT PREVENT EXECUTION OF THE WORK AS INDICATED, THE
CONTRACTOR MUST IMMEDIATELY NOTIFY THE CONTRACTING OFFICER IN
WRITING AND AWAIT DIRECTION BEFORE PROCEEDING WITH THE WORK.
COORDINATE LOCATION OF DEVICES/APPLIANCES, TERMINAL CABINETS, AND
REMOTE PANELS WITH TECHNICIAN.
NOTE: FULL-TONE SOLID, AND FULL-TONE DASHED SYMBOLS REPRESENT
EXISTING DEVICES BEING DEMOLISHED IN PHASE 1. SHADED AREA IS NOT
UNDER CURRENT CONSTRUCTION PACKAGE UNLESS NOTED OTHERWISE -
WORK TO BE PERFORMED IN THE SHADED AREAS MUST BE COORDINATED
WITH COR FOUR WEEKS PRIOR TO MINIMIZE MISSION IMPACT.
GENERAL NOTES - DEMOLITION W ORK
1. NO ANTICIPATED WORK IN THIS AREA.
KEYED NOTES - DEMOLITION W ORK
KEY PLAN
N
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
1 2 3 4 5
D
C
B
A
8'4' 16'
CUI
CUI
C U
I
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
D
AY
TO
N , O
H
IO
R
EP
AI
R
/R
EN
O
VA
TE
A
FM
C
H Q
B U
IL
D
IN
G
(B
2)
P H
AS
E
B262 PHASE
P2 N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
J.
B
EN
SO
N
FAD108A
AR
EA
D
EM
O
LI
TI
O
N C
EI
LI
N G
P
LA
N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
JA
C
O
BS
E N
G
IN
EE
R
IN
G
G R
O U
P
IN
C
N . B
R O
AD
W
AY
S
T.
L
O U
IS
, M
O . 6
J.
A.
B
EA
LS
S.
S.
R O
D R
IG
U
EZ
C .W
. K R
IE
BE
L
O
C
TO
BE
R
W
2Q R
R
XX
XX
B10262 PHASE 1 - FINAL 90% REVISED - NOT FOR CONSTRUCTION
BA
SE
M
EN
T -A
R
EA
P H
AS
E
FI
R
E P
R O
TE
C
TI
O
N D
EM
O
LI
TI
O N
1/8" = 1'-0"A1 FIRE ALARM AND MASS NOTIFICATION BASEMENT DEMOLITION PLAN - AREA 8
W
2Q R
R
_P la ns _P
H 1_
Vo l4
-0
M
T
S
R
Q
N
4 5 6 7 8 9 10 11 12
MA
TC
HL
IN
E
A1
FA
D1
A
MATCHLINE
A1 FAD108A
MA
TC
HL
IN
E
A1
FA
D1
A
TS
C
WF
C
(2
1. REFER TO SHEET FA001 FOR FIRE ALARM AND MASS NOTIFICATION GENERAL
NOTES, SYMBOLS, AMD ABBREVIATIONS.
2. REVISE OR DEMOLISH EXISTING MANUAL PULL STATIONS, DETECTORS,
NOTIFICATION APPLIANCES, INTERFACE MODULES, AND ANY ASSOCIATED
CONDUIT AND WIRING ACCORDING TO THE SELECTIVE AREAS AS INDICATED
ON THE OVERALL SHEETS. SIGNALING LINE AND NOTIFICATION APPLIANCE
CIRCUITS MUST BE MODIFIED IN ORDER TO MAINTAIN FIRE ALARM SERVICE
THROUGHOUT THE OCCUPIED AREAS OF THE FACILITY.
3. COORDINATE SHUT DOWN OF ALL EXISTING SYSTEMS WITH PROJECT
MANAGER AND THE WRITTEN APPROVAL OF USACE.
4. MAINTAIN CIRCUIT INTEGRITY OF ALL EXISTING SIGNALING LINE CIRCUITS AND
NOTIFICATION APPLIANCE CIRCUITS TO…