NCARNG_Wilmington_RC_Addendum_1_Drawings_20170817_Part_3.pdf

PDF 1 MB Posted

Attached to
Wilmington Readiness Center
Solicitation number
W91242-17-B-0005
Issued by

About this file

Updated Drawings Part 3 08/17/2017

View the file

Other files

File Type Posted
OF_1419-_Abstract_Wilmington_Armory.pdf PDF
Questions_and_Answers_165.pdf PDF
Questions_and_Answers_162-164.pdf PDF
W91242-17-B-0005-0005_Released.pdf PDF
262913.03_-_Manual_and_Magnetic_Motor_Controllers.pdf PDF
W91242-17-B-0005-0004_Released.pdf PDF
105613_fl_-_metal_storage_shelving.pdf PDF
Questions_and_Answers_135-161.pdf PDF
015000_fl_-_temporary_facilities_and_controls.pdf PDF
010000_fl-_general_requirements.pdf PDF
012300_fl_-_additive_bid_items_(abi).pdf PDF
NCARNG_WIlmington_Amendment_Drawings_20170824.pdf PDF
Questions_and_Answers_80-134.pdf PDF
W91242-17-B-0005-0003_Released.pdf PDF
083313_fl_-_coiling_counter_doors.doc.pdf PDF
MILCON_Erosion_Control_Letter_of_Approval.pdf PDF
271513_FL_-_Communications_Copper_Horizontal_Cabling.pdf PDF
W91242-17-B-0005-0002.pdf PDF
State_Stormwater_Management_Permit_No._SW8_140906.pdf PDF
084113_fl_-_aluminum-framed_entrances_and_storefronts.pdf PDF
NCARNG_Wilmington_RC_Addendum_1_Drawings_20170817_Part_1.pdf PDF
Questions_and_Answers_60-79.pdf PDF
084413_fl_-_glazed_aluminum_curtain_walls.pdf PDF
083323_fl_-_overhead_coiling_doors.pdf PDF
133423.10_fl_-_fabricated_storage_building.pdf PDF
087100_-_door_hardware.pdf PDF
312000_FL_-_Earth_Moving.pdf PDF
114000_-_food_service_equipment.pdf PDF
NCARNG_Wilmington_RC_Addendum_1_Drawings_20170817_Part_2.pdf PDF
013300_fl_-_submittal_procedures.pdf PDF
Questions_and_Answers_41-59.pdf PDF
Questions_and_Answers_8-17-17.pdf PDF
Prebid_Attendance_Roster.pdf PDF
PreBidSlides_W91242-17-B-0005_a.ppt PPT presentation
NCARNG_RC_Bid_Final_Submittal_Drawings_Volume_2_20170619.pdf PDF
NCARNG_RC_Bid_Final_Specs_Volume_2_20170707.pdf PDF
NCARNG_RC_Bid_Final_Specs_Volume_1_20170707.pdf PDF
NCARNG_RC_Bid_Final_Submittal_Drawings_Volume_1__20170619.pdf PDF
W91242-17-B-0005-0001_Released.pdf PDF
W91242-17-B-0005_Released.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ROOM FINISH SCHEDULE GENERAL NOTES

1. REFER TO PLANS FOR PARTITION TYPES.

2. PROVIDE "V" SHAPED CONTROL JOINTS IN GYPSUM BOARD ASSEMBLIES AT 30'-0" OC

MAXIMUM OR AS NOTED. COORDINATE LOCATIONS WITH ARCHITECT PRIOR TO

CONSTRUCTION - REFER TO A3/ A-704

3. PROVIDE FIRESTOPPING AT PERIMETERS AND PENETRATIONS OF FIRE RATED GYPSUM

BOARD ASSEMBLIES.

4. PROVIDE TRANSITION STRIPS AT ALL CHANGES IN FLOOR FINISH MATERIALS. REFER TO

DRAWING A-552.

5. PAINT ALL STEEL DOORS AND FRAMES.

6. ALL FINISHES SHALL BE APPROVED BY THE NORTH CAROLINA ARMY NATIONAL GUARD

PRIOR TO INSTALLATION.

7. FOR EXTERIOR COLOR SCHEDULE REFER TO DRAWING A-201.

8. ALL PIPING NOT CONCEALED IN PARTITIONS OR ABOVE CEILING SHALL BE PAINTED.

REFER TO SPECIFICATIONS.

9. PROVIDE LEVEL 5 FINISH UNDER ALL DRY ERASE WALLCOVERINGS

10. WHERE CERAMIC TILE FLOORING REQUIRES A TILE JOINT, REFER TO B3/A-552

ROOM FINISH SCHEDULE LEGEND

FLOORS

CPT TILE CARPETING

CFT CERAMIC FLOOR TILE

CONC CONCRETE

ESD STATIC- CONTROL RESILIENT

FLOORING

POL POLISHED CONCRETE

SEAL SEALED CONCRETE

RAF RESILIENT ATHLETIC FLOORING

REM ENTRANCE FLOOR MAT AND FRAME

RES RESINOUS EPOXY

RTR RESILIENT TREADS AND RISERS

VCT RESILIENT FLOORING

BASE

-- NONE

RB 4" RESILIENT BASE

CWB CERAMIC WALL BASE

WALLS / PARTITIONS

CMU CONCRETE MASONRY UNIT

GLAZ GLAZING

DAP DECORATIVE ACOUSTIC PANELING

GYP GYPSUM

-- NONE

DEW DRY ERASE WALLCOVERING

P PREFINISHED

PT PAINT

CWT CERAMIC WALL TILE

FP FOLDING PANEL PARTITION

BR BRICK

CEILINGS

APC 24" x 24" ACOUSTICAL PANEL

CEILING

EFS EXTERIOR FINISH SYSTEM

EXP EXPOSED STRUCTURE

GYP GYPSUM BOARD

-- NONE

VAR VARIES

P PREFINISHED

PT PAINT

ROOM FINISH SCHEDULE REMARKS

1. PAINT ALL EXPOSED STEEL COLUMNS, BRACES, GIRTS, DECKS, AND

MISCELLANEOUS FRAMING STEEL UNLESS OTHERWISE NOTED.

2. PROVIDE 1/2" CEMENT BOARD UNDER ALL WALL/PARTITION TILE OVER STUDS.

REFER TO ELEVATIONS FOR TILE PATTERNS.

3. AT ALL ROOMS DESIGNATED AS "IT", "TELECOMMUNICATION", OR "TELECOM",

PROVIDE 3/4", A/C GRADE OR BETTER, VOID-FREE, FIRE- RESISTANT PLYWOOD

KILN-DRIED TO MAX MOISTURE CONTENT OF 15 PERCENT, ON FACE OF ALL

PARTITIONS (COORDINATE WITH TELECOM REQUIREMENTS). EXTEND PLYWOOD

FROM FLOOR TO 8'-0" AFF. FASTEN PLYWOOD THROUGH GYPSUM BOARD TO STEEL

STUDS WITH 2" SCREWS AT 16" OC EACH WAY. PRIME AND PAINT PLYWOOD TO

MATCH PARTITION. GYPSUM BOARD CONCEALED BY PLYWOOD NEED NOT BE

PAINTED.

4. IMPACT RESISTANT GYPSUM BOARD TO 8'-0" AFF.

5. ROOMS 133 AND 134 ARE AN ABI.

6. PROVIDE 5/8" GLASS MAT GYPSUM BOARD AS BASE FOR EXTERIOR FINISH SYSTEM

(EFS). EFS SHALL BE PREFINISHED.

7. ROOM SHALL PREVENT THE PASSAGE OF SMOKE TO INTERIOR ROOMS.

8. DO NOT INSTALL RESILIENT BASE ON FOLDING PARTITION.

9. DO NOT INSTALL RESILIENT BASE ON CMU PARTITIONS AND WALLS.

10. REFER TO INTERIOR ELEVATIONS FOR LOCATION OF AND INDENTIFICATION OF FINISHES.

11. RESINOUS FLOORING WILL BE AN ABI FLOOR COVERING IN LIEU OF SEALED CONCRETE

FLOOR. 4" COVED RESINOUS BASE IN LIEU OF RESILIENT BASE ON ALL WALLS/

PARTITIONS. FOR COVED BASE AT CMU OR GYPSUM BOARD REFER TO A3/A-552 SIMILAR.

12. RESINOUS MATRIX TERRAZZO FLOORING AND BASE WILL BE AN ABI FLOOR COVERING IN

LIEU OF POLISHED CONCRETE.

13. 6" COVED RESINOUS BASE. REFER TO A3/A-552. CONDITION SIMILAR AT GYPSUM BOARD.

14. GROUND FACE CMU WILL BE AN ABI IN LIEU OF PAINTED CMU.

15. PROVIDE PLASTIC PANELING ON FACE OF ALL PARTITIONS ABOVE THE WALL BASE TO A

HEIGHT OF 4'-6" AFF. SEAL ALL EDGES.

ROOM FINISH SCHEDULE

D

C

B

A

1 2 3 4 5

BID FINAL SUBMITTAL

Designed:

Drawn :

Checked:

Drawing No.:

Date:

Drawing Title:

Scales:

P R

O J E

C T

N O

W

IL

M

IN

G T

O N

N

O R

T H

C A

R O

L

IN

A

N A

T

IO

N A

L G

U A

R D

R E

A D

IN

E

S S

C E

N T

E R

N O

R T

H C

A R

O L

IN

A

A R

M Y

N A

T

IO

N A

L G

U A

R D

03 APRIL 2017

DATEREV DESCRIPTION

501 North Broadway, Saint Louis, Missouri 63102

DISCLAIMER

ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE

ONLY FOR THE PURPOSE OF AUTHENTICATING THIS

DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS

RELATING TO THIS PROJECT IS DISCLAIMED

NC Engineering Firm License No. F-0287 NC Architectural Firm No. 50757

B

IM

/U

S

N o rt h C a ro lin a A rm y N a ti o n a l G u a rd

F W

/N

C A

R N

G R e a d in e s s C e n te r_ A

R C

H V

.r v t

/1

/2

:0 :5

P

M

A-601DEF

JAD

AJT

ARCHITECTURAL

ROOM FINISH SCHEDULE

ROOM

NO. ROOM NAME

FLOORING BASE NORTH WALL/PARTITION EAST WALL/PARTITION SOUTH WALL/PARTITION WEST WALL/PARTITION CEILING

CEILING

HIEGHT REMARKS

SUBSTRATE

MATERIAL

FLOORING

SYSTEM

FLOORING

COLOR

SUBSTRATE

MATERIAL

BASE

SYSTEM BASE COLOR

SUBSTRATE

MATERIAL

FINISH

SYSTEM

FINISH

COLOR

SUBSTRATE

MATERIAL

FINISH

SYSTEM

FINISH

COLOR

SUBSTRATE

MATERIAL

FINISH

SYSTEM

FINISH

COLOR

SUBSTRATE

MATERIAL

FINISH

SYSTEM FINISH COLOR

SUBSTRATE

MATERIAL

FINISH

SYSTEM

FINISH

COLOR

FIRST FLOOR

101 ELECTRICAL CONC SEAL SC-1 CMU/GYP RB RB-1 CMU PT PT-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 4

102 CORRIDOR CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4

103 FACILITY STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 CMU PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4, 7

104 FACILITY STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4, 7

105 FACILITY STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4, 7

106 MULTIPURPOSE TRAINING ROOM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 10'-0" 11

107 CLASSROOM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT GYP PT PT-4 GYP PT PT-1 - APC APC-1 10'-0" 8, 11

108 CLASSROOM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT - APC APC-1 10'-0" 8, 11

109 STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - - - 8'-0" 11

111 LEARNING CENTER CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 10'-0" 11

112 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

113 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 11

114 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

115 HHC CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

116 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11

117 FAMILY READINESS CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11

118 VESTIBULE CONC REM REM-1 GLAZ/BR - - GLAZ P PT-1 BR - PT-1 GLAZ P PT-1 BR - PT-1 GYP EFS EFS-1 12'-0" 6

119 LOBBY CONC POL PC-1 - - - - - - - - - - - - - - - - - - - 4, 10, 12

120 WELLNESS ROOM CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 11

121 SEATING CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

122 RECRUITING OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11

123 RETENTION OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

124 RETENTION OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11

125 TABLES AND CHAIRS STORAGE CONC SEAL SC-1 CMU RB RB-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 11

126 CUSTODIAL CONC RES RES-1 CMU/GYP RES RESB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 15

127 SCULLERY CONC RES RES-1 CMU RES RESB-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 GYP EFS EFS-1 9'-0" 6, 13

128 SERVERY CONC RES RES-1 CMU/GYP RES RESB-1 CMU PT PT-1 - - PT-1 GYP PT PT-1 CMU PT PT-1 GYP EFS EFS-1 9'-0" 6, 13

129 KITCHEN CONC RES RES-1 CMU/GYP RES RESB-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 CMU PT PT-1 GYP EFS EFS-1 9'-0" 6, 13

130 DRY STORAGE CONC RES RES-1 CMU/GYP RES RESB-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 GYP EFS EFS-1 9'-0" 6, 13

131 TOILET CONC RES RES-1 CMU/GYP RES RESB-1 GYP CWT CWT-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-1 GYP EFS EFS-1 9'-0" 6, 13

132 ASSEMBLY HALL CONC SEAL SC-1 CMU RB RB-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 11, 14

133 GENERAL PURPOSE TRAINING BAYS CONC SEAL SC-1 CMU - - CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 9, 5

134 VESTIBULE CONC REM REM-1 CMU RB RB-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 GYP EFS EFS-1 9'-0" 5, 12

135 SUPPLY AFF CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 1

136 STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 1, 7

137 SUPPLY SGT CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 1

138 VESTIBULE CONC SEAL SC-1 CONC, GYP RB RB-1 CONC PT PT-1 GYP PT PT-1 GYP PT PT-1 - - PT-1 EXP PT PT-2 VARIES 1, 11

139 VAULT CONC SEAL SC-1 CONC - - CONC PT PT-1 CONC PT PT-1 CONC PT PT-1 CONC PT PT-1 CONC PT PT-2 8'-8"

140 UNIT STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 CMU PT PT-1 CONC/ GYP PT PT-4 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1

141A UNHEATED STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 CMU PT PT-1 GYP PT PT-1 CMU PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4, 9

141B UNHEATED STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4, 9

142 FIRE PUMP ROOM CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 4, 9

143 MECHANICAL CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 4, 9

144 MAIL VESTIBULE CONC SEAL SC-1 CMU - - CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 9

145 MAIL ROOM CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 9

146 MAIL PICK UP CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1

147A UNIT LOCKERS CONC SEAL SC-1 CMU/GYP RB RB-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 9

147B UNIT LOCKERS CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 9

147C UNIT LOCKERS CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 9

148 PHYSICAL FITNESS CONC RAF RAF-1 CMU/GYP RB RB-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-3 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4

149 TELECOM EQUIPMENT CONC ESD ESD-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 9'-0" 1, 3

150 MENS SHOWERS CONC CFT CFT-1 CMU/GYP CWB CWB-1 GYP CWT CWT-1 GYP CWT CWT-1 CMU CWT CWT-1 CMU PT CWT-1 GYP EFS EFS-1 9'-0" 2, 6, 10

151 CUSTODIAL CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1

152 MENS TOILET CONC SEAL SC-1 CMU/GYP CWB CWB-1 GYP PT/CWT PT-4, CWT-1 GYP CWT CWT-1, CWT-2 CMU CWT CWT-1 GYP CWT CWT-1 GYP EFS EFS-1 9'-0" 2, 6, 10, 11

153 WOMENS TOILET CONC SEAL SC-1 CMU/GYP CWB CWB-1 GYP PT/CWT PT-4, CWT-1 GYP CWT CWT-1 CMU CWT CWT-1 GYP CWT CWT-1, CWT-2 GYP EFS EFS-1 9'-0" 2, 6, 10, 11

154 ELECTRICAL CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 11

155 WOMENS SHOWERS CONC CFT CFT-1 GYP CWB CWB-1 GYP CWT CWT-1 GYP PT CWT-1 GYP CWT CWT-1 GYP CWT CWT-1 GYP EFS EFS-1 9'-0" 2, 6, 10

156 STAIRS CONC SEAL, RTR SC-1, RTR-1 CMU/GYP RB RB-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1

157 STAIRS CONC SEAL, RTR SC-1, RTR-1 CMU/GYP RB RB-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1

158A CORRIDOR CONC POL PC-1 CMU/GYP RB RB-1 GYP PT PT-1 - - PT-1 GYP PT PT-1 CMU PT PT-1 - APC APC-1 9'-0" 4, 12

158B CORRIDOR CONC POL PC-1 CMU/GYP RB RB-1 - - PT-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 4, 12, 14

159 STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

160 ELEVATOR CONC - - - - - CMU - - CMU - - CMU - CMU - - EXP - - VARIES

166 RECYCLE STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 CMU/ GYP PT PT-1 EXP PT PT-2 VARIES 4, 9

SECOND FLOOR

201 S2 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 11

202 S2 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 11

203 S2 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

204 S6 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11

205 S6 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

206 S4 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11

207 S4 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

208 CHAP OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11

209 OPEN OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

210 S1 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11

211 S1 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

212 S1 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11

213 PRINT ROOM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11

214 S3 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11

215 ADMINISTRATION CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 10'-0" 11

216 S3 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

217 S3 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 11

218 S3 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 11

219 AO OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

220 O5 COMMANDER OFFICE CONC CPT CPT-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0"

221 X0 OFFICE CONC CPT CPT-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0"

222 BATTALION COMMAND CONC CPT CPT-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0"

223 CMD SGT MJ OFF CONC CPT CPT-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0"

224 COMMAND CONFERENCE ROOM CONC CPT CPT-1 GYP RB RB-1 GYP PT PT-1 GYP DEW DEW-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0"

225 STORAGE CONC VCT VCT-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0"

226 STORAGE CONC VCT VCT-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0"

227 CUSTODIAL CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 4

228 WOMENS TOILET CONC SEAL SC-1 CMU/GYP CWB CWB-1 GYP PT/CWT PT-3, CWT-1 CMU PT PT-3 CMU CWT CWT-1 GYP CWT CWT-1 GYP EFS EFS-1 9'-0" 2, 6, 10, 11

229 MENS TOILET CONC SEAL SC-1 CMU/GYP CWB CWB-1 GYP PT/CWT PT-3, CWT-1 GYP CWT CWT-1 CMU CWT CWT-1 GYP PT PT-3 GYP EFS EFS-1 9'-0" 2, 6, 10, 11

230 FACILITY STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4, 7

231 BREAK ROOM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-3 GYP PT PT-4 CMU PT PT-4 - - - - APC APC-1 9'-0" 11

232 ELECTRICAL CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 11

233 TELECOM EQUIPMENT CONC ESD ESD-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 3, 11

234 BREAK OUT ROOM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-3 - - - GYP PT PT-4 GYP DEW DEW-1 - APC APC-1 9'-0" 11

235 CURRENT OPERATIONS CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-4 GYP DEW DEW-1 GYP PT PT-1 GYP DEW DEW-1 - APC APC-1 10'-0" 11

236 AUDITORIUM CONC SEAL SC-1 GYP RB RB-1 GYP DEW DEW-1 GYP DEW DEW-1 GYP PT PT-1 GYP DEW DEW-1 - APC APC-1 10'-0" 11

237 ELECTRICAL CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 1

238 TA STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 1, 4

239 TA STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 1, 4

240 TA STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 1, 4

241 AV CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 1, 7

242 PHYSICIAN ASSISTANT CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 8'-0" 11

243 PA STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 1, 4, 7, 11

244 EXAM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

245 MEDICAL EXAM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11

247 CORRIDOR CONC POL PC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 4, 11

248 STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 CMU PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VAIRES 1

1 ADDENDUM 1 08/16/17

1. DOOR DETAILS ARE ON DRAWINGS A-603 THRU A-607 UNLESS OTHERWISE NOTED.

2. ALL WOOD DOORS SHALL BE PREFINISHED - REFER TO SPECIFICATIONS.

3. ALL STEEL DOORS AND FRAMES SHALL BE PAINTED.

4. DO NOT PAINT LABELS OF TESTING AGENCY ON FIRE-RATED DOORS AND FRAMES.

5. ALL EXTERIOR STEEL DOORS AND FRAMES SHALL BE GALVANIZED. SOME INTERIOR

DOORS AND FRAMES ARE GALVANIZED. REFER TO DOOR SCHEDULE. WIPE COAT

GALVANIZED STEEL IS NOT ACCEPTABLE.

6. ALL FIRE-RATED DOORS SHALL BE SELF-CLOSING AND SELF-LATCHING.

7. FIRE DOORS AND FRAMES SHALL HAVE AN APPROVED LABEL OR LISTING MARK

INDICATING THE FIRE-PROTECTION RATING, WHICH IS PRIMARILY AFFIXED AT THE

FACTORY WHERE FABRICATION AND ASSEMBLY ARE PERFORMED.

8. FIRE-RATED DOOR FRAMES SHALL BE INSTALLED STRICTLY PER MANUFACTURER'S

PRINTED INSTRUCTIONS. MANUFACTURER'S PRINTED INSTRUCTIONS SHALL BE MADE

AVAILABLE TO THE INSPECTION AUTHORITY.

9. ALL EXTERIOR DOORS SHALL BE INSULATED.

10. IF PAVEMENT ON EXTERIOR SIDE OF MAN DOORS IS NOT INDICATED AND DETAILED BY

CIVIL - REFER TO A2 / A-605 OR B2 / A-605.

11. ALL EXIT DOOR HARDWARE SHALL ALLOW DOORS TO BE OPENED IN THE DIRECTION OF

EXIT WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.

12. THE MAXIMUM EXTERIOR DOOR OPENING EFFORTS SHALL NOT EXCEED 8.5 POUNDS.

13. BOTH THE LATCHING AND DEAD BOLT DEVICES ON EXTERIOR DOORS SHALL RELEASE

WITH A SINGLE ACTION OF THE INSIDE LEVER.

14. HINGES FOR OUT-SWINGING EXTERIOR DOORS SHALL BE EQUIPPED WITH NON-

REMOVABLE HINGE PINS IF NOT SCHEDULED TO RECEIVE CONTINUOUS HINGE.

15. REMOVABLE GLAZING STOPS AT BORROW LITES SHALL BE INSTALLED ON SECURE SIDE.

16. DO NOT CAULK BACK BEND STEEL DOOR FRAMES TO GYPSUM BOARD PARTITIONS.

17. THE DOOR FRAME MANUFACTURER SHALL VERIFY ACTUAL WALL / PARTITION THICKNESS

WITH CONTRACTOR PRIOR TO FABRICATION OF DOOR FRAMES.

18. REFER TO SPECIFICATIONS FOR HARDWARE GROUPS.

19. AT ALL EXTERIOR DOORS IN CMU, CONTINUE FLUID APPLIED AIR BARRIER ONTO JAMB

BLOCK TO BE COVERED BY DOOR FRAME.

DOOR SCHEDULE GENERAL NOTES

1. GALVANIZED DOOR AND FRAME

2. INSULATED DOOR

3. UNDERCUT DOOR 3/4" COORDINATE BOTTOM/UNDERCUT OF DOORS WITH FINISH

MATERIALS, THRESHOLDS, ETC.

4. SMOKE SEALED DOOR (HEAD AND JAMBS ONLY)

5. GALVANIZED FRAME

6. ELECTRIC POWERED DOOR

7. OVERHEAD COILING DOOR SIZE AND COILING COUNTER DOOR SIZE INDICATED IS FOR

FINISHED OPENING. ACTUAL DOOR SIZE WILL BE LARGER BASED ON

MANUFACTURER'S STANDARDS.

8. CERAMIC TILE SHALL BE FIT TO DOOR FRAME.

9. PREFINISHED DOOR

10. POWER-ASSISTED ENTRANCE DOOR ON RIGHT HAND REVERSE.

11. PREPARE DOOR AND FRAME FOR BALANCED MAGNETIC SWITCH - REFER TO C1/A-603

12. PROVIDE COAT HOOK CENTERED ON BACK SIDE OF DOOR AT 5'-6" AFF

13. CARD READER WITH KEYPAD

14. ELECTRIFIED LOCK WITH 120V POWER SUPPLY (RHR)

15. VAULT DOOR - REFER TO A4 / A-606

16. FOR DETAIL OF KEYED REMOVABLE MULLION REFER TO B4 / A-606

17. DOOR AND FRAME ARE PART OF BLAST-RESISTANT EXTERIOR FACADE - REFER TO

SPECIFICATION SECTION 089500

18. DOOR AND FRAME ARE INCLUDED IN ABI.

19. IN ABI CHANGE HEAD DETAIL TO D1 / A-606, CHANGE JAMB DETAIL TO C1 / A-606, AND

CHANGE SILL DETAIL TO B1 / A-606. CHANGE DOOR AND FRAME TO 90 MINUTE FIRE

RATING.

20. IN ABI CHANGE HEAD DETAIL TO B3 / A-606, CHANGE JAMB DETAIL TO A3 / A-606, AND

CHANGE SILL DETAIL TO B1 / A-606.

21. MANUFACTURER'S STANDARD HEAD DETAIL.

22. DOOR THICKNESS SHALL BE AS REQUIRED BY MANUFACTURER TO ACCOMODATE

GLASS TYPE INDICATED.

23. DOOR THICKNESS PER MANUFACTURER.

DOOR SCHEDULE REMARKS

ALUM ALUMINUM

HM HOLLOW METAL

MFR HARDWARE BY DOOR

MANUFACTURER

STL STEEL

SS STAINLESS STEEL

WD SOLID CORE WOOD

1/4" CLEAR TEMPERED (PROVIDE FIRE RATED

GLASS IN NARROW LITE DOORS)

DOOR SCHEDULE LEGEND

GLASS TYPE SCHEDULE

G1

G2

G3

G4

G5

G6

G7

1/4" CLEAR LAMINATED

1 1/4" TINTED INSULATED

1 1/4" SPANDREL INSULATED

1 1/4" CLEAR INSULATED (SAFETY APPLICATION)

1 1/4" TINTED INSULATED (SAFETYAPPLICATION)

1 1/2" TINTED INSULATED

SCHEDULED DOOR

D

IM

E N

S

IO

N E

N

LA

R G

E D

F O

R C

LA

R

IT

Y

3/ 8"

M A

X

IM

U M

4"MAXIMUM

4 7/8"

4 1/8"

STANDARD ANSI

CUTOUT FOR MORTISE

INSTALLATION

HIGH SECURITY

CONCEALED MAGNETIC

CONTACT

HIGH SECURITY

CONCEALED MAGNETIC

CONTACT

STANDARD ANSI

CUTOUT FOR MORTISE

INSTALLATION

SCHEDULED DOOR

FRAME

2" 2"

4" R

E F

E R

T O

S C

H E

D U

LE

DOOR FRAME

FINISH FLOOR

2"

2"4" R

E F

E R

T O

S C

H E

D U

LE DOOR FRAME

FINISH FLOOR

1' - 6" 2"

2"

4" R

E F

E R

T O

S C

H E

D U

LE

DOOR FRAME

FINISH FLOOR

2"

KEYED

REMOVABLE

MULLION

G1

NOTE: FOR STOREFRONT

DOOR FRAMES REFER TO A-604

4"

REFER TO

SCHEDULE

REFER

TO SCHEDULE

REFER TO

SCHEDULE

2" 2"

2" R

E F

E R

T O

S C

H E

D U

LE

DOOR FRAME

FINISH FLOOR

2"

2" R

E F

E R

T O

S C

H E

D U

LE

DOOR FRAME

FINISH FLOOR

2"

KEYED

REMOVABLE

MULLION

REFER

TO SCHEDULE

REFER TO

SCHEDULE

2"

2"2" R

E F

E R

T O

S C

H E

D U

LE DOOR FRAME

FINISH FLOOR

1' - 6"

2"

G1

4"

REFER TO

SCHEDULE

2"

2"2" R

E F

E R

T O

S C

H E

D U

LE

FINISH FLOOR

1' - 0" 2"

4"

REFER TO

SCHEDULE

2" 2"

3'

2" 4'

0"

G1

2" 3' - 8" 2"

2" 2"

2'

0" 6'

0"

G2

2" 5' - 0" 2"

D3/D4

A-606

B3

A-605

B4

A-605

B4

A-605

B4

A-605

B3

A-605

DOOR FRAME

G1

B3

A-605

D4

A-605

B1

A-605

C4

A-605

B2

A-607

B4

A-607

A2

A-607

OPPOSITE

D4

A-605

D4

A-605

FLUSH DOOR

FLUSH PANEL

DOOR - REFER

TO SCHEDULE

FOR MATERIAL

FOVERHEAD COILINGOH

PREFINISHED

SLATS

REFER

TO SCHEDULE

R E

F E

R T

O S

C H

E D

U

LE

REFER

TO SCHEDULE

R E

F E

R T

O S

C H

E D

U

LE

FULL GLASS

GLASS:

TYPE AS

SCHEDULED

FG

3 1/2"

1/

2"

NARROW LITE

GLASS:

TYPE AS

SCHEDULED

NL

3/

4"

FLUSH PANEL

DOOR - REFER

TO SCHEDULE

FOR MATERIAL

6"4"

REFER TO

SCHEDULE

2'

1"

R E

F E

R T

O S

C H

E D

U

LE

REFER

TO SCHEDULE

R E

F E

R T

O S

C H

E D

U

LE

VAULT DOOR

HIGH SECURITY

ELECTOMECHANICAL

LOCK FOR VAULT

DOOR UL GROUP

V

R E

F E

R T

O S

C H

E D

U

LE

COILING COUNTERCC

S C

H E

D U

LE

R E

F E

R T

O

SCHEDULE

REFER TO

REFER

TO SCHEDULE

FINISH FLOOR

PREFINISHED

SLATS

SECURITY MESH

DUTCH

SM

R E

F E

R T

O S

C H

E D

U

LE

REFER

TO SCHEDULE

GLASS:

TYPE AS

SCHEDULED

FGI

1/

2"

3 1/2"

REFER TO

SCHEDULE

R E

F E

R T

O S

C H

E D

U

LE

DOOR SCHEDULE

D

C

B

A

1 2 3 4 5

BID FINAL SUBMITTAL

Designed:

Drawn :

Checked:

Drawing No.:

Date:

Drawing Title:

Scales:

P R

O J E

C T

N O

W

IL

M

IN

G T

O N

N

O R

T H

C A

R O

L

IN

A

N A

T

IO

N A

L G

U A

R D

R E

A D

IN

E

S S

C E

N T

E R

N O

R T

H C

A R

O L

IN

A

A R

M Y

N A

T

IO

N A

L G

U A

R D

03 APRIL 2017

DATEREV DESCRIPTION

501 North Broadway, Saint Louis, Missouri 63102

DISCLAIMER

ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE

ONLY FOR THE PURPOSE OF AUTHENTICATING THIS

DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS

RELATING TO THIS PROJECT IS DISCLAIMED

NC Engineering Firm License No. F-0287 NC Architectural Firm No. 50757

B

IM

/U

S

N o rt h C a ro lin a A rm y N a ti o n a l G u a rd

F W

/N

C A

R N

G R e a d in e s s C e n te r_ A

R C

H V

.r v t

/1

/2

:0 :5

P

M

A-603DEF

JAD

AJT

ARCHITECTURAL

DOOR SCHEDULE, TYPES,

AND DETAILS

DOOR

NO.

DOOR FRAME

FIRE RATING REMARKSTYPE MATERIAL GLAZING SIZE: WIDTH x HEIGHT THICKNESS TYPE MATERIAL HEAD DETAIL JAMB DETAIL SILL DETAIL

101A F HM - 4'-0" X 7'-0" 1 3/4" 1 HM D4 / A-607 C4 / A-607 A4 / A-605 - 1, 2, 17

101B F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 5, 9

102 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9

103 F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 4

104 F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 4

105 F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 4

106A F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9

106B F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9

107 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9

108 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9

109 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9

111 F WD - 3'-0" X 7'-0" 1 3/4" 1 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9

112 F WD - 3'-0" X 7'-0" 1 3/4" 7 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12

113 F WD - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12

114 F WD - 3'-0" X 7'-0" 1 3/4" 7 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12

115 F WD - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9

116 F WD - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12

117 FG ALUM G1 3'-0" X 7'-0" 1 3/4" B5 / A-610 ALUM B3 / A-557 C1 / A-557

C2 / A-557

A5 / A-605 - 23

118A FG ALUM G3 PR 3'-0" X 7'-0" - W5 / A-610 ALUM D5 / A-557 D1 / A-557

D3 / A-557

B1 / A-606 - 2, 10, 16, 23

118B FG ALUM G3 PR 3'-0" X 7'-0" - W5 / A-610 ALUM D5 / A-557 D1 / A-557

D3 / A-557

B1 / A-606 - 2, 16, 23

118C FG ALUM G4 PR 3'-0" X 7'-0" - W6 / A-610 ALUM D5 / A-557 D1 / A-557

D3 / A-557

A1 / A-606 - 2, 10, 11, 14, 16, 23

118D FG ALUM G4 PR 3'-0" X 7'-0" - W6 / A-610 ALUM D5 / A-557 D1 / A-557

D3 / A-557

A1 / A-606 - 2, 16, 23

120 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A4 / A-605 - 9, 12

121 F WD - 3'-0" X 7'-0" 1 3/4" 3 HM B2 / A-511 A4 / A-607 A5 / A-605 - 9

122 F WD - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12

123 F WD - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12

124 F WD - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12

125 F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D1 / A-606 C1 / A-606 A5 / A-605 - 4

126 F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D1 / A-605 C1 / A-605 A5 / A-605 - 1

127 CC SS - 4'-0" X 3'-10" - - - B4 / A-511

SIMILAR

B2 / A-606 A1 / A-607 - 7, 23

128A F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D1 / A-606 C1 / A-606 A5 / A-605 - 1

128B F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D1 / A-606 C1 / A-606 A5 / A-605 - 1

130 F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 17

131 F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D1 / A-605 C1 / A-605 A5 / A-605 - 1

132A F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17

132B F HM PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17, 18, 19

132C F WD - PR 6'-0" X 7'-0" 1 3/4" 2 HM D1 / A-606 C1 / A-606 A4 / A-605 45 MIN 9, 16

132D F WD - PR 6'-0" X 7'-0" 1 3/4" 2 HM D1 / A-606 C1 / A-606 A4 / A-605 45 MIN 9, 16

132E OH SS - 6'-0" X 8'-0" - - - B4 / A-511 B2 / A-606 A2 / A-606 45 MIN 7, 23

133A F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 17, 18

133B OH ALUM - 16'-0" X 16'-0" - - STEEL D3 / A-607 C3 / A-607 A3 / A-605 - 2, 6, 7, 17, 18, 23

133C F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D1 / A-606 C1 / A-606 B1 / A-606 90 MIN 1, 2, 18

133D OH ALUM - 16'-0" X 16'-0" - - STEEL D3 / A-607 C3 / A-607 A3 / A-605 - 2, 6, 7, 17, 18, 23

133E F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 17, 18

134 F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17, 18

135A F HM - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 1

135B - - - - - 8 HM D4 / A-605 C4 / A-605 B1 / A-605 - 5

135C - - - - - 8 HM D4 / A-605 C4 / A-605 B1 / A-605 - 5

135D - - - - - 8 HM D4 / A-605 C4 / A-605 B1 / A-605 - 5

136 F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 4, 5

137A F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 - 5, 12

137B - - - - - 8 HM D4 / A-605 C4 / A-605 B1 / A-605 - 5

137C - - - - - 8 HM D4 / A-605 C4 / A-605 B1 / A-605 5

138 F HM - PR 3'-0" X 7'-0" 1 3/4" 5 HM D5 / A-605 C5 / A-605 A5 / A-605 90 MIN 11, 16

139 V STL - AS NOTED 3 1/4" - STL D5 / A-606 C5 / A-606 B5 / A-606 - 15

140A F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17

140B SM STL - PR 6'-0" X 7'-0" - - STL - C2 / A-554 D3 / A-555

SIMILIAR

- 21

141A F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17

141B F WD - PR 3'-0" X 7'-0" 1 3/4" 5 HM B5 / A-607 A5 / A-607 A5 / A-605 90 MIN 4, 9, 16

142 F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17

143A F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17

144 F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D4 / A-607 C4 / A-607 A4 / A-605 - 1, 2, 17

145A F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D3 / A-606 A3 / A-606 A5 / A-605 - 1

145B F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9

146 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9

147A F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17

147B F WD - PR 3'-0" X 7'-0" 1 3/4" 5 HM B5 / A-607 A5 / A-607 A5 / A-605 90 MIN 4, 9, 16

147C F WD - PR 3'-0" X 7'-0" 1 3/4" 5 HM B5 / A-607 A5 / A-607 A5 / A-605 90 MIN 4, 9, 16

148 F WD - PR 3'-0" X 7'-0" 1 3/4" 5 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 16

149 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9

150 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D3 / A-605 C3 / A-605 A4 / A-552 - 8, 9

151 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9

154 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9

155 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D3 / A-605 C3 / A-605 A4 / A-552 - 8, 9

156A F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D4 / A-607 C4 / A-607 A4 / A-605 - 1, 2, 17

156B F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 45 MIN 9

156C NL WD GI 3'-0" X 7'-0" 1 3/4" 1 HM D2 / A-605 C2 / A-605 A3 / A-605 45 MIN 9

157A F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D2 / A-607 C1 / A-607 AND

C2 / A-607

A4 / A-605 - 1, 2, 17

157B F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 45 MIN 9

157C NL WD GI 3'-0" X 7'-0" 1 3/4" 1 HM D2 / A-605 C2 / A-605 A5 / A-605 45 MIN 9

158A FG1 HM G6 PR 3'-0" X 7'-0" 1 3/4" 2 HM A1 / A-511 B1 / A-541 A4 / A-605 - 1, 2, 11, 14, 16, 17, 22

158B F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 17, 18, 20

159 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-606 C2 / A-606 A5 / A-606 - 9

166A F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9, 4

166B F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 1, 4

3" = 1'-0"C1

DETAIL

1/4" = 1'-0"A1

FRAME TYPES

1/4" = 1'-0"B1

DOOR TYPES

1/4" = 1'-0"

2' 4' 8' 12'

- FIRST FLOOR

NOT TO SCALE

A-603

EVACUATION PLAN

Evacuation Instructions

Legend

FLOOR PLAN

DRAWN TO SCALE

FLOOR SPECIFIC

EVACUATION INSTRUCTIONS

THAT MEET LOCAL FIRE CODE,

BUILDING CODE, AND NCARNG

REQUIREMENTS

LEGEND SHALL INCLUDE BUT

NOT BE LIMITED TO; VIEW

LOCATION ICON, PRIMARY

EXIT ROUTE, SECONDARY EXIT

ROUTE, FIRE EXTINGUISHER,

EMERGENCY SHOWER/EYE

WASH STATION, AND AED

NOTE:

VERIFY DESIGN AND

LOCATION OF EVACUATION

PLANS WITH NCARNG

EVACUATION PLAN IN

ALUMINUM FRAME WITH

NON-GLARE SHATTER-PROOF

COVER

17"

FIRE ALARM

1/8" THICK PAINTED

ALUMINUM SIGN

MECHANICALLY APPLIED

EXTERIOR SIGN PANEL

WHITE TYPE STYLE ON

PANTONE 18-0601 TPX

CHARCOAL GRAY

BACKGROUND

SPRINKLER

WHEN BELL RINGS

CALL 911

2' - 0"

1'

6"

2" 2"

NOTES:

1. SIGN SHALL BE ACRYLIC

2. PROVIDE 1/32" HIGH RAISED CHARACTERS

3. SANS SERIF TYPE STYLE

4. CHARACTER SHALL BE WHITE ON PANTONE 18-1222 TPX

NUTMEG BROWN BACKGROUND

5. ON GLASS APPLICATIONS PROVIDE BLANK COVERS ON

OPPOSITE SIDE

6. CENTER SIGN ON DOOR

GRADE 2 BRAILLE

5' -0

A

F F

2" 3"

1"

6"

9"

MEN WOMEN

BLUE FIELD 1/4" THICK,

TYPICAL

WHITE GRAPHICS AND

TYPE STYLE RAISED 1/32",

TYPICAL

GRADE 2 BRAILLE

MEN WOMEN

NOTES:

1. PROVIDE APPROPRIATE GEOMETRIC SYMBOL LOCATED ON THE PARTITION

ADJACENT TO THE LATCH SIDE THE ENTRANCE DOOR AT A HEIGHT OF 60" TO

THE CENTER OF THE SYMBOL. THE COLOR AND CONTRAST OF THE SYMBOL

SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR OF THE DOOR.

2. SIGN SHALL BE ACRYLIC.

3. PROVIDE 1/32" HIGH RAISED CHARACTERS AND SYMBOLS.

4. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, PLACE SIGN ON THE

NEAREST ADJACENT WALL. LOCATE SIGNS SO THAT A PERSON MAY

APPROACH WITHIN 3 INCHES OF SIGNAGE WITHOUT ENCOUNTERING

PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR.

5. SANS SERIF TYPE STYLE.

6. MINIMUM GRAPHICS HEIGHT 3".

TYPICAL

6" MINIMUM

T Y

P

IC

A L

6" M

IN

IM

U M

PROVIDE DIRECTIONAL

ARROWS AS REQUIRED,

TYPICAL

1/8" THICK PAINTED

ALUMINUM SIGN

MECHANICALLY APPLIED

INTERIOR SIGN PANEL

WHITE TYPE STYLE ON

PANTONE 18-0601 TPX

CHARCOAL GRAY

BACKGROUND

INSTALLING CONTRACTOR

SHALL FILL IN VALUES

INCLUDING NAME OF

INSTALLING CONTRACTOR

2. RESIDUAL PRESSURE

AT THE BASE OF THE

RISER

3. STATIC PRESSURE

1. WATER FLOW RATE

SYSTEM DEMAND

2. DESIGNED AREA

OF DISCHARGE

1. DENSITY

THIS BUILDING IS PROTECTED A

HYDRAULICALLY DESIGNED

AUTOMATIC SPRINKLER SYSTEM

NO. OF SPRINKLERS

BASIS FOR DESIGN

LOCATION

HYDRAULIC SYSTEM

OCCUPANCY

CLASSIFICATION

4. HOSE STREAM

ALLOWANCE

NOTE: SIGN SHALL COMPLY

WITH 2016 NFPA 13.25.5

SMOKING

PROHIBITED WITHIN

50 FEET OF THE

BUILDING PERIMETER

WHITE TYPE STYLE ON

PANTONE 18-0601 TPX

CHARCOAL GRAY

BACKGROUND

1/8" THICK

PAINTED

ALUMINUM SIGN

MECHANICALLY

FASTENED

EXTERIOR SIGN

1'

4" 1' - 4"

THIS IS A NON-SMOKING FACILITY

PLAN VIEW

ELEVATION VIEW

7’ -0

A

F F

NOTES:

SIGN BASIS OF DESIGN MANUFACTURER: Safehouse Signs, Inc. (OR APPROVED EQUAL)

AT FIRE EXTINGUISHERS: PRODUCT - PWS 4

AT AED: PRODUCT - PWS 100

PARTITION

6” H x 12” W x 1/8” THICK VINYL

PROJECTING PARTITON SIGN

CENTER ON FIRE EXTINGUISHER,

FIRE PROTECTION CABINET, OR

FIRE ALARM PULL STATION BELOW

FASTENING:

USE MANUFACTURER'S

RECOMMENDED TAPE AND

SCREWS WITH WASHERS

FASTENING METHOD

ROOM IDENTIFICATION SIGN:

FOR PRIVATE OFFICES, SIGN MESSAGE

SHALL BE 6" - 7" TYPE WRITTEN INSERT

SAN SERIF TYPE STYLE

NCARNG

WHITE TYPE STYLE ON

PANTONE 18-0601 TPX

CHARCOAL GRAY

BACKGROUND

1/2" 1/2"

7"

3/ 4"

5/ 8"

5/ 8"

5/ 8"

1/ 2"

1/ 2"

7"

OFFICE

1/

2"

RADIUS ALL CORNERS

SIGNAGE GENERAL NOTES

1. DRAWING INDICATES DESIGN INTENT ONLY.

2. ALL ROOM SIGNAGE NUMBERS SHALL BE EXACTLY THE SAME AS THOSE INDICATED ON THE

PLANS WITHOUT EXCEPTION.

3. LEGEND SYMBOLS INDICATE LOCATION OF A SIGN. FINAL LOCATION SHALL BE FIELD

COORDINATED WITH ARCHITECT AND NORTH CAROLINA ARMY NATIONAL GUARD.

4. SIGNAGE CONTRACTOR SHALL BE RESPONSIBLE FOR THE FABRICATION AND INSTALLATION

OF ALL SIGNS AND SHALL BE RESPONSIBLE FOR THE DESIGN AND ENGINEERING OF ALL

STRUCTURAL, ATTACHMENT, ANCHORING, AND FOUNDATION FEATURES UNLESS

OTHERWISE NOTED.

5. SIGNAGE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL

CONDITIONS RELATED TO THE INSTALLATION OF SIGNS.

6. ALL HARDWARE AND FASTENERS SHALL BE CONCEALED UNLESS OTHERWISE NOTED.

FINISH ALL EXPOSED HARDWARE AND FASTENERS TO MATCH SUPPORTING SIGN SURFACES

(COLOR) UNLESS OTHERWISE NOTED.

7. SIGNAGE SHALL BE MOUNTED ON LATCH SIDE OF DOORS UNLESS OTHERWISE INDICATED.

REFER TO D4 / G-120. SIGNAGE DESIGNATED TO BE ACCESSIBLE SHALL COMPLY WITH THE

CURRENT ADAAG STANDARDS.

8. "*" ON SIGNAGE SCHEDULE INDICATED SIGN IN ACCESSIBLE AREA AND SHALL INCLUDE

GRADE 2 BRAILLE.

9. FOR ADDITIONAL REQUIREMENTS OF SIGNS ON IDENTIFICATION REFER TO G-120.

10. FOR ILLUMINATED EXIT SIGNS REFER TO ELECTRICAL DRAWINGS.

11. PROJECTING AND OVERHEAD SIGNS SHALL COMPLY WITH DETAIL A4 / G-120.

12. PROVIDE SIGN ABOVE BRACKET-MOUNTED FIRE EXTINGUISHERS - REFER TO B3 / A-713.

REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF FIRE EXTINGUISHERS.

13. PROVIDE SIGN ABOVE AUTOMATIC EXTERNAL DEFIBRILLATOR - REFER TO B3 / A-713.

14. ALL ROOM SIGNS OF TYPE 'RI' SHALL HAVE A THREE-DIGIT ROOM NUMBER IN ADDITION TO

THE ROOM NAME.

15. PRIVATELY OCCUPIED ROOMS SHALL HAVE A REMOVABLE NAME TAG FOR OCCUPANT -

COORDINATE NAME WITH NORTH CAROLINA ARMY NATIONAL GUARD.

16. ALL REMOVABLE NAME TAGS SHALL BE SUCH THAT NORTH CAROLINA ARMY NATIONAL

GUARD CAN PRINT / CHANGE WITHOUT SPECIAL EQUIPMENT.

17. FOR SITE AND TRAFFIC SIGNAGE REFER TO CIVIL DRAWINGS.

18. FOR BUILDING IDENTIFICATION SIGN AT ROADWAY REFER TO LANDSCAPE DRAWINGS.

19. SIGNS ON SYSTEMS FURNITURE WILL BE GFGI. SYSTEMS FURNITURE IS NOT IN CONTRACT.

20. FOR ELEVATOR RELATED SIGNAGE REFER TO ELEVATOR SPECIFICATION.

ROOM

NAME

1' - 4"

1'

4"

1/8" THICK PAINTED

ALUMINUM SIGN

MECHANICALLY APPLIED

EXTERIOR SIGN PANEL

WHITE SANS SERIF TYPE STYLE

ON PANTONE 18-0601 TPX

CHARCOAL GRAY BACKGROUND.

CENTER TEXT HORIZONTALLY

AND VERTICALLY. REFER TO 'IN'

TYPE SIGN KEY FOR ROOM NAME

E Q

E Q

1' - 4"

1'

4"

1/8" THICK PAINTED

ALUMINUM SIGN

MECHANICALLY APPLIED

INTERIOR SIGN PANEL

WHITE SANS SERIF TYPE STYLE

ON PANTONE 18-0601 TPX

CHARCOAL GRAY BACKGROUND.

MAXIMUM

OCCUPANCY

REFER TO LIFE SAFETY PLANS

FOR MAXIMUM OCCUPANT LOAD

FIRST FLOOR

EL: 100' - 0"

9'

0" 8"

7" 6"

EQUAL EQUAL

8'

0"

EQUALEQUAL

9" ARIAL TEXT SHALL

BE ALUMINUM

6" ARIAL TEXT SHALL

BE ALUMINUM

8'-0" DIAMETER

LOGO (GFGI)

SIGNAGE FINISH SHALL

MATCH BLACK SEMI-GLOSS

20059, PMS 476.

D2

A-713

3" FORMED METAL PANELS

(MP1)

1 1/2" THERMAL INSULATION

CMU

PIN MOUNTED DIMENSIONAL

LETTER SIGNAGE. DRILL AND SET

INTO CMU PER MANUFACTURER'S

RECOMMENDATIONS - SEAL

TIGHT PENETRATIONS OF

FORMED METAL PANELS

PANTONE 18-0601 TPX CHARCOAL

GRAY BACKGROUND ON 1/4" THICK

ALUMINUM WALL MOUNTED SIGN.

2" 2"

3' - 4"

2" 2"

1'

0"

WHITE REFLECTIVE LETTERS

AND NUMBERS IN 12" ARIAL

BOLD, CENTERED ON SIGN,

COMLIANT WITH AR 420-70.

NOTES:

1. PRIOR TO FABRICATION CONFIRM BUILDING NUMBER WITH NORTH

CAROLINA ARMY NATIONAL GUARD.

2. EXTERIOR SIGN PANEL. MECHANICALLY APPLIED TO BRICK VENEER.

3. FOR MOUNTNG HEIGHT REFERENCE EXTERIOR ELEVATIONS.

D

C

B

A

1 2 3 4 5

BID FINAL SUBMITTAL

Designed:

Drawn :

Checked:

Drawing No.:

Date:

Drawing Title:

Scales:

P R

O J E

C T

N O

W

IL

M

IN

G T

O N

N

O R

T H

C A

R O

L

IN

A

N A

T

IO

N A

L G

U A

R D

R E

A D

IN

E

S S

C E

N T

E R

N O

R T

H C

A R

O L

IN

A

A R

M Y

N A

T

IO

N A

L G

U A

R D

03 APRIL 2017

DATEREV DESCRIPTION

501 North Broadway, Saint Louis, Missouri 63102

DISCLAIMER

ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE

ONLY FOR THE PURPOSE OF AUTHENTICATING THIS

DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS

RELATING TO THIS PROJECT IS DISCLAIMED

NC Engineering Firm License No. F-0287 NC Architectural Firm No. 50757

B

IM

/U

S

N o rt h C a ro lin a A rm y N a ti o n a l G u a rd

F W

/N

C A

R N

G R e a d in e s s C e n te r_ A

R C

H V

.r v t

/1

/2

:0 :5

P

M

A-713DEF

JAD

AJT

ARCHITECTURAL

SIGNAGE TYPES

AND DETAILS

NOT TO SCALEA1

SIGN TYPE EV

0 6" 1'

3" = 1'-0"

3"

0 2'

1 1/2" = 1'-0"

6" 1'

A-411

1 1/2" = 1'-0"A2

SIGN TYPE SFA

A-711

3" = 1'-0"A3

SIGN TYPE TE

A-711

NOT TO SCALEA4

SIGN TYPE TR

A-711

NOT TO SCALEB1

SIGN TYPE IN-3

A-711

3" = 1'-0"B2

SIGN TYPE IN-4

A-711

3" = 1'-0"B3

FIRE EXTINGUISHER / AED SIGN

A-533

3" = 1'-0"B4

SIGN TYPE RI

A-711

1 1/2" = 1'-0"C1

SIGN TYPE IN

A-711

IN-1 MECHANICAL ROOM

IN-2 ELECTRICAL ROOM / INVERTER

IN-3 REFER TO B1 / A-713

IN-4 REFER TO B2 / A-713

IN-5 UNIT LOCKERS

IN-6 FIRE PUMP

IN-7 REFER TO C3 / A-713

IN-8 UNIT STORAGE

IN-9 ASSEMBLY HALL

IN-10 FOOD SERVICE

IN-11 UNHEATED STORAGE

IN-12 MAIL DELIVERY

IN-13 GENERAL PURPOSE TRAINING BAYS

'IN' TYPE SIGNAGE KEY

SIGN ROOM NAME

1 1/2" = 1'-0"C3

SIGN TYPE IN-7

A-711

3/8" = 1'-0"D1

BUILDING SIGNAGE

1 1/2" = 1'-0"D2

BUILDING SIGNAGE DETAIL

A-711 A-713

3/8" = 1'-0"

8'2' 4'1'

1" = 1'-0"C4

SIGN TYPE BN - BUILDING NUMBER SIGN

A-712

0 2'

1" = 1'-0"

6" 1' 3' dimartj Snapshot dimartj Rectangle dimartj Snapshot dimartj Cloud dimartj Snapshot dimartj Rectangle dimartj Cloud dimartj Snapshot dimartj Line dimartj Snapshot dimartj Line dimartj Rectangle

A

1/2" TEE

1/2" DIA X 2'-0" LONG

CONDENSATE AND DIRT LEG

1/2" COMPRESSED

AIR DROP

1/2" SHUT-OFF VALVE

1/2" FPT COMBINATION

PRESSURE REGULATING

VALVE/IN-LINE FILTER WITH

INTEGRAL PRESSURE

GAUGE; OPERATING RANGE 5

PSI TO 125 PSI; INTEGRAL 25

MICRON FILTER

REDUCING TEE

FINISHED FLOOR

COMPRESSED AIR

MAIN, SEE PLANS

FOR SIZES

AIR OUTLET, FEMALE

QUICK COUPLER TYPE

WITH BUILT-IN AUTOMATIC

CHECK UNIT. SIZE/STYLE

PER CONTRACTING

OFFICER

SUPPORT VERTICAL

RISER AGAINST WALL

PER SPECIFICATIONS

PIPE CAP

1/2" BLOW-OFF VALVE

4' -0

' A

FF

EYE-WASH

PLUGGED NIPPLE

PUSH LEVER

EXTENSION SPLIT

CLAMP PIPE HANGER

SECURED TO WALL

1" CHAIN OPERATED

BALL VALVE

PULL

HANDLE

SHOWER

HEAD

NOTE: ALARM AND STROBE LIGHT

NOT SHOWN.

85°

SUPPLY (ALTERNATE)

EXTERIOR WALL

STANDARD 1-1/4"

PIPE FLANGE

1 1/4" WASTE AT

2'-0" AFF TO SPILL

ON-GRADE

EXPANSION BOLTS,

4 REQUIRED

FINISHED

FLOOR/ GRADE

DWH-2

1 1/4"

1 1/4" TEPID WATER

OUTSIDE INSIDE

ESE-2

PROVIDED WITH

AUTOMATIC THERMAL

ACTUATOR FREEZE

PROTECTION BLEED

VALVE

24"

4" PIPE

AND FITTINGS

STANDARD-

TEE OR ELBOW

PER LOCAL CODE

3", 6" AND 12" GR2432

GRADE RINGS AS

REQUIRED

24" CAST IRON FRAMES AND COVERS WITH

GASKET (GAS TIGHT) 2 TOTAL

RATED FOR HEAVY TRAFFIC

REFER TO CIVIL

SITE PLAN FOR

LOCATION

320 GALLON CAPACITY

3' -7

3' -4

” 4' -6

INLET

OUTLET

BOTTOM OUTLET

CONNECTION ELEVATION

SHALL BE A MAXIMUM OF 18

INCHES BELOW FINISHED

FLOOR.

CATCH BASIN (SAND INTERCEPTOR)

WITH BOTTOM OUTLET.

SECTIONAL TRENCH WITH SECURED EXTRA HEAVY

DUTY SLOTTED DUCTILE IRON GRATES APPROXIMATELY

24' LONG IN WORK BAYS. MAXIMUM DEPTH SHALL BE 18

INCHES. UNIT SHALL BE SUITABLE FOR TRACKED

VEHICLE TRAFFIC.

RECEIVER

120 GAL

AC-1

2" CA TO MAINTENANCE

WORKBAYS REF PLANS

FOR CONTINUATION

FINISHED

FLOOR

DRAIN

VALVE

AIR COOLED

AFTER COOLERSAIR INLET FILTER

D

C

B

A

1 2 3 4 5

BID FINAL SUBMITTAL

Designed:

Drawn :

Checked:

Drawing No.:

Date:

Drawing Title:

Scales:

P R

O J E

C T

N O

W

IL

M

IN

G T

O N

N

O R

T H

C A

R O

L

IN

A

N A

T

IO

N A

L G

U A

R D

R E

A D

IN

E

S S

C E

N T

E R

N O

R T

H C

A R

O L

IN

A

A R

M Y

N A

T

IO

N A

L G

U A

R D

03 APRIL 2017

DATEREV DESCRIPTION

501 North Broadway, Saint Louis, Missouri 63102

DISCLAIMER

ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE

ONLY FOR THE PURPOSE OF AUTHENTICATING THIS

DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS

RELATING TO THIS PROJECT IS DISCLAIMED

NC Engineering Firm License No. F-0287 NC Architectural Firm No. 50757

B

IM

/U

S

N o rt h C a ro lin a A rm y N a ti o n a l G u a rd

F

W

/N

C A

R N

G

R e a d in e s s C e n te r_

P L

U M

B V

.r v t

/1

/2

:5

:2

A

M

P-502JOT

APB

APB

PLUMBING

DETAILS

ABI No. 1 & 2

NOT TO SCALEC3

COMPRESSED AIR OUTLET DETAIL - ABI No. 2

NOT TO SCALEA1

EMERGENCY SHOWER & EYEWASH DETAIL - ABI No. 1

NOT TO SCALEC2

OIL/WATER SEPARATOR DETAIL - ABI No. 2

NOT TO SCALEC1

TD-1 TRENCH DRAIN DETAIL - ABI No. 2

P-502 P-502 P-502

P-502

NOT TO SCALEA2

DUPLEX AIR COMPRESSOR DETAIL

P-502

1 Revision 1 08/16/16

C

A

B

3/4"ø HWR 1 1/4"ø HW

1 1/2"ø CW

3/4"ø CW

3/ 4" ø C

W

1"ø CW

1/ 2" ø C

W

1/ 2" ø H

W 3" ø S

S 1 1/

4" ø

C W

1/

4" ø

H W

3/ 4" ø C

W

4"ø SS

3/4"ø HWR 1 1/4"ø HW

1 1/2"ø CW

WH-1WH-1

ESE-1

AC

GENERAL PURPOSE TRAINING BAYS

VESTIBULE

ASSEMBLY HALL

2"ø CA 2"ø CA

1/ 2" ø C

A

1/ 2" ø C

A

HB-1 HB-1

SK-3

1/ 2" ø C

A

1/ 2" ø C

A 2"ø CA

2" ø

C A

2" ø

C A

TD-1 TD-1

4"ø SS

3"ø SS

6"ø SS

4"ø SS

6"ø SS

4" ø

S S

FCO

REFER TO CIVIL

DRAWING CS400 FOR

CONTINUATION

4"SS

I.E. 95.33

3"SS

I.E. 95.33

REFER TO A1/P-801

FOR CONTINUATION

N

D

C

B

A

1 2 3 4 5

BID FINAL SUBMITTAL

Designed:

Drawn :

Checked:

Drawing No.:

Date:

Drawing Title:

Scales:

P R

O J E

C T

N O

W

IL

M

IN

G T

O N

N

O R

T H

C A

R O

L

IN

A

N A

T

IO

N A

L G

U A

R D

R E

A D

IN

E

S S

C E

N T

E R

N O

R T

H C

A R

O L

IN

A

A R

M Y

N A

T

IO

N A

L G

U A

R D

03 APRIL 2017

DATEREV DESCRIPTION

501 North Broadway, Saint Louis, Missouri 63102

DISCLAIMER

ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE

ONLY FOR THE PURPOSE OF AUTHENTICATING THIS

DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS

RELATING TO THIS PROJECT IS DISCLAIMED

NC Engineering Firm License No. F-0287 NC Architectural Firm No. 50757

B

IM

/U

S

N o rt h C a ro lin a A rm y N a ti o n a l G u a rd

F

W

/N

C A

R N

G

R e a d in e s s C e n te r_

P L

U M

B V

.r v t

/1

/2

:5

:2

A

M

P-802JOT

APB

APB

PLUMBING

ENLARGED PLAN

ABI No. 2

PLUMBING PLAN GENERAL NOTES

1. REFER TO P-001 FOR SYMBOLS AND ABBREVIATIONS.

1/4" = 1'-0"

P-801

A1 ENLARGED PLUMBING PLAN - ABI No. 2

1/4" = 1'-0"

2' 4' 8' 12'

9 6" SANITARY SEWER FROM GREASE TRAP BY SITE CONTRACTOR(SHOWN FOR CLARITY

ONLY). REFER TO DRAWING CS400 FOR EXACT LOCATION AND INVERT ELEVATION.

KEYED NOTES

1 Revision 1 08/16/16

EWC-1

MB-1

SH-1

WC-1

SH-1

SH-2

SK-1

WC-1

WC-1

WC-1

WC-2

L-1

L-1

L-1

L-1

L-1

L-1L-1

L-1

U-2

SH-1

SH-1

SH-1

SH-1

SH-2

WC-2

WC-1

WC-1

1/2"CW AND 1/2"HW

UP TO MB-1

3/4"CW TO WH-1

PIPING UP TO ASSEMBLY

HALL CEILING SPACE.

FOR CONTINUATION

REFER TO A1/P-105.

FOR CONTINUATION

REFER TO A1/P-801

2"CW UP AND

3/4"HW UP TO

SECOND FLOOR

3/4"CW TO WH-1

1"ø HW

1/2"ø HW

2"ø CW

1"ø CW

1/2"ø HW 1/2"ø CW

1/2"ø CW

2"ø CW

1/2"ø CW

3/4"ø HW

2"ø CW

3/4"ø CW

1/2"ø HW

2 1/2"ø CW 1 1/4"ø HW 1"ø HW (140°F) 1"ø HWR 3/4"ø HWR (140°F)

3/4"ø HWR (140°F) 1"ø HWR 1"ø HW (140°F) 1 1/4"ø HW

2 1/2"ø CW

1"ø HW

3/4"ø CW

1"ø HW

1/2"ø HW

1"ø HW

1/2"ø CW

1/2"ø CW

1/2"ø HW

TP-1

TP-1

FOR CONTINUATION

REFER TO A1/P-105.

FOR CONTINUATION REFER TO A3/P-103

WH-1

3/4"ø HWR (140°F)

1"ø HWR

1"ø HW (140°F)

1 1/4"ø HW

2"ø CW

1/2"ø HW1/2"ø HW

1/2"ø CW1/2"ø CW

1/2"ø HW (140°F)

3/4"ø CW

1/2"ø HW

1/2"ø CW

1/2"ø HW 1/2"ø CW

3/4"ø CW

1 1/4"ø CW

3/4"ø HWR

1 1/2"ø CW

1"ø HW

1"ø HW (140°F)

3/4"ø HWR

3/4"ø HWR (140°F)

1/2"ø CW

1/2"ø HW

3/4"ø CW

3/4"ø CW 3/4"ø HW 3/4"ø HW (140°F)

1/2"ø CW

1/2"ø HW

WH-1

L-1

1/2"CW BELOW GRADE TO

COLD FOOD COUNTER

4"CW

FOR CONTINUATION REFER

TO CIIVL DRAWINGS

4"ø CW 3/4"ø CW

WH-1

TP

ET

ST

DWH

MV-1

CP

CP

HB-1

3/4"ø CW

2 1/2"ø CW 2"ø HW

1"ø HW (140°F)

1"ø HWR

3/4"ø HWR (140°F)

4"ø CW

4"ø CW

3/4"ø CW

3/4"ø HWR

2"ø HW (140°F)

3/4"ø HWR

CP

FOR CONTINUATION

REFER TO A1/P-102

MB-1

EWC-1

L-1

L-1

L-1

L-1 U-2

U-1

WC-1

WC-1WC-1WC-2

WC-2

WC-1

WB-1

WB-1

SK-2

WB-1 1/2"CW FROM

FIRST FLOOR

1/2"CW AND

1/2"HW FROM

FIRST FLOOR

1/2"CW AND

1/2"HW FROM

FIRST FLOOR

1/2"CW DOWN

TO FIRST FLOOR

3/4"HW DOWN

TO FIRST FLOOR

3/4"HW FROM

FIRST FLOOR

2"CW FROM

FIRST FLOOR

D

C

B

A

1 2 3 4 5

BID FINAL SUBMITTAL

Designed:

Drawn :

Checked:

Drawing No.:

Date:

Drawing Title:

Scales:

P R

O J E

C T

N O

W

IL

M

IN

G T

O N

N

O R

T H

C A

R O

L

IN

A

N A

T

IO

N A

L G

U A

R D

R E

A D

IN

E

S S

C E

N T

E R

N O

R T

H C

A R

O L

IN

A

A R

M Y

N A

T

IO

N A

L G

U A

R D

03 APRIL 2017

DATEREV DESCRIPTION

501 North Broadway, Saint Louis, Missouri 63102

DISCLAIMER

ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE

ONLY FOR THE PURPOSE OF AUTHENTICATING THIS

DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS

RELATING TO THIS PROJECT IS DISCLAIMED

NC Engineering Firm License No. F-0287 NC Architectural Firm No. 50757

B

IM

/U

S

N o rt h C a ro lin a A rm y N a ti o n a l G u a rd

F

W

/N

C A

R N

G

R e a d in e s s C e n te r_

P L

U M

B V

.r v t

/1

/2

:5

:2

A

M

P-902JOT

APB

APB

PLUMBING

WATER

RISERS

A1

FIRST FLOOR TOILET ROOM DOMESTIC WATER ISOMETRIC

B1

KITCHEN DOMESTIC WATER ISOMETRIC

B2

MECHANICAL ROOM DOMESTIC WATER ISOMETRIC

PLUMBING PLAN GENERAL NOTES

1. REFER TO P-001 FOR SYMBOLS AND ABBREVIATIONS.

7 PROVIDE DRAIN DOWN FOR TRAPPED PIPING AT THIS LOCATION. REFER TO DETAIL

A4/P-501.

18 HOT WATER BOOSTER HEATER. ROUTE 180°F HW PIPE (NOT SHOWN) TO SANITIZER

FAUCET OF TRIPLE BOWL SINK.

19 HAND SINK

20 DUAL BOWL VEGETABLE SINK

21 ICE MAKER

22 TRIPLE BOWL SINK

25 CAN WASH

KEYED NOTES

A3

SECOND FLOOR TOILET ROOM DOMESTIC WATER ISOMETRIC

1 Revision 1 08/16/16

File details come from the government source that posted it. Updated .