ROOM FINISH SCHEDULE GENERAL NOTES
1. REFER TO PLANS FOR PARTITION TYPES.
2. PROVIDE "V" SHAPED CONTROL JOINTS IN GYPSUM BOARD ASSEMBLIES AT 30'-0" OC
MAXIMUM OR AS NOTED. COORDINATE LOCATIONS WITH ARCHITECT PRIOR TO
CONSTRUCTION - REFER TO A3/ A-704
3. PROVIDE FIRESTOPPING AT PERIMETERS AND PENETRATIONS OF FIRE RATED GYPSUM
BOARD ASSEMBLIES.
4. PROVIDE TRANSITION STRIPS AT ALL CHANGES IN FLOOR FINISH MATERIALS. REFER TO
DRAWING A-552.
5. PAINT ALL STEEL DOORS AND FRAMES.
6. ALL FINISHES SHALL BE APPROVED BY THE NORTH CAROLINA ARMY NATIONAL GUARD
PRIOR TO INSTALLATION.
7. FOR EXTERIOR COLOR SCHEDULE REFER TO DRAWING A-201.
8. ALL PIPING NOT CONCEALED IN PARTITIONS OR ABOVE CEILING SHALL BE PAINTED.
REFER TO SPECIFICATIONS.
9. PROVIDE LEVEL 5 FINISH UNDER ALL DRY ERASE WALLCOVERINGS
10. WHERE CERAMIC TILE FLOORING REQUIRES A TILE JOINT, REFER TO B3/A-552
ROOM FINISH SCHEDULE LEGEND
FLOORS
CPT TILE CARPETING
CFT CERAMIC FLOOR TILE
CONC CONCRETE
ESD STATIC- CONTROL RESILIENT
FLOORING
POL POLISHED CONCRETE
SEAL SEALED CONCRETE
RAF RESILIENT ATHLETIC FLOORING
REM ENTRANCE FLOOR MAT AND FRAME
RES RESINOUS EPOXY
RTR RESILIENT TREADS AND RISERS
VCT RESILIENT FLOORING
BASE
-- NONE
RB 4" RESILIENT BASE
CWB CERAMIC WALL BASE
WALLS / PARTITIONS
CMU CONCRETE MASONRY UNIT
GLAZ GLAZING
DAP DECORATIVE ACOUSTIC PANELING
GYP GYPSUM
-- NONE
DEW DRY ERASE WALLCOVERING
P PREFINISHED
PT PAINT
CWT CERAMIC WALL TILE
FP FOLDING PANEL PARTITION
BR BRICK
CEILINGS
APC 24" x 24" ACOUSTICAL PANEL
CEILING
EFS EXTERIOR FINISH SYSTEM
EXP EXPOSED STRUCTURE
GYP GYPSUM BOARD
-- NONE
VAR VARIES
P PREFINISHED
PT PAINT
ROOM FINISH SCHEDULE REMARKS
1. PAINT ALL EXPOSED STEEL COLUMNS, BRACES, GIRTS, DECKS, AND
MISCELLANEOUS FRAMING STEEL UNLESS OTHERWISE NOTED.
2. PROVIDE 1/2" CEMENT BOARD UNDER ALL WALL/PARTITION TILE OVER STUDS.
REFER TO ELEVATIONS FOR TILE PATTERNS.
3. AT ALL ROOMS DESIGNATED AS "IT", "TELECOMMUNICATION", OR "TELECOM",
PROVIDE 3/4", A/C GRADE OR BETTER, VOID-FREE, FIRE- RESISTANT PLYWOOD
KILN-DRIED TO MAX MOISTURE CONTENT OF 15 PERCENT, ON FACE OF ALL
PARTITIONS (COORDINATE WITH TELECOM REQUIREMENTS). EXTEND PLYWOOD
FROM FLOOR TO 8'-0" AFF. FASTEN PLYWOOD THROUGH GYPSUM BOARD TO STEEL
STUDS WITH 2" SCREWS AT 16" OC EACH WAY. PRIME AND PAINT PLYWOOD TO
MATCH PARTITION. GYPSUM BOARD CONCEALED BY PLYWOOD NEED NOT BE
PAINTED.
4. IMPACT RESISTANT GYPSUM BOARD TO 8'-0" AFF.
5. ROOMS 133 AND 134 ARE AN ABI.
6. PROVIDE 5/8" GLASS MAT GYPSUM BOARD AS BASE FOR EXTERIOR FINISH SYSTEM
(EFS). EFS SHALL BE PREFINISHED.
7. ROOM SHALL PREVENT THE PASSAGE OF SMOKE TO INTERIOR ROOMS.
8. DO NOT INSTALL RESILIENT BASE ON FOLDING PARTITION.
9. DO NOT INSTALL RESILIENT BASE ON CMU PARTITIONS AND WALLS.
10. REFER TO INTERIOR ELEVATIONS FOR LOCATION OF AND INDENTIFICATION OF FINISHES.
11. RESINOUS FLOORING WILL BE AN ABI FLOOR COVERING IN LIEU OF SEALED CONCRETE
FLOOR. 4" COVED RESINOUS BASE IN LIEU OF RESILIENT BASE ON ALL WALLS/
PARTITIONS. FOR COVED BASE AT CMU OR GYPSUM BOARD REFER TO A3/A-552 SIMILAR.
12. RESINOUS MATRIX TERRAZZO FLOORING AND BASE WILL BE AN ABI FLOOR COVERING IN
LIEU OF POLISHED CONCRETE.
13. 6" COVED RESINOUS BASE. REFER TO A3/A-552. CONDITION SIMILAR AT GYPSUM BOARD.
14. GROUND FACE CMU WILL BE AN ABI IN LIEU OF PAINTED CMU.
15. PROVIDE PLASTIC PANELING ON FACE OF ALL PARTITIONS ABOVE THE WALL BASE TO A
HEIGHT OF 4'-6" AFF. SEAL ALL EDGES.
ROOM FINISH SCHEDULE
D
C
B
A
1 2 3 4 5
BID FINAL SUBMITTAL
Designed:
Drawn :
Checked:
Drawing No.:
Date:
Drawing Title:
Scales:
P R
O J E
C T
N O
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
N A
T
IO
N A
L G
U A
R D
R E
A D
IN
E
S S
C E
N T
E R
N O
R T
H C
A R
O L
IN
A
A R
M Y
N A
T
IO
N A
L G
U A
R D
03 APRIL 2017
DATEREV DESCRIPTION
501 North Broadway, Saint Louis, Missouri 63102
DISCLAIMER
ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE
ONLY FOR THE PURPOSE OF AUTHENTICATING THIS
DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS
RELATING TO THIS PROJECT IS DISCLAIMED
NC Engineering Firm License No. F-0287 NC Architectural Firm No. 50757
B
IM
/U
S
N o rt h C a ro lin a A rm y N a ti o n a l G u a rd
F W
/N
C A
R N
G R e a d in e s s C e n te r_ A
R C
H V
.r v t
/1
/2
:0 :5
P
M
A-601DEF
JAD
AJT
ARCHITECTURAL
ROOM FINISH SCHEDULE
ROOM
NO. ROOM NAME
FLOORING BASE NORTH WALL/PARTITION EAST WALL/PARTITION SOUTH WALL/PARTITION WEST WALL/PARTITION CEILING
CEILING
HIEGHT REMARKS
SUBSTRATE
MATERIAL
FLOORING
SYSTEM
FLOORING
COLOR
SUBSTRATE
MATERIAL
BASE
SYSTEM BASE COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM
FINISH
COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM
FINISH
COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM
FINISH
COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM FINISH COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM
FINISH
COLOR
FIRST FLOOR
101 ELECTRICAL CONC SEAL SC-1 CMU/GYP RB RB-1 CMU PT PT-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 4
102 CORRIDOR CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4
103 FACILITY STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 CMU PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4, 7
104 FACILITY STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4, 7
105 FACILITY STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4, 7
106 MULTIPURPOSE TRAINING ROOM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 10'-0" 11
107 CLASSROOM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT GYP PT PT-4 GYP PT PT-1 - APC APC-1 10'-0" 8, 11
108 CLASSROOM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT - APC APC-1 10'-0" 8, 11
109 STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - - - 8'-0" 11
111 LEARNING CENTER CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 10'-0" 11
112 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
113 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 11
114 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
115 HHC CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
116 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11
117 FAMILY READINESS CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11
118 VESTIBULE CONC REM REM-1 GLAZ/BR - - GLAZ P PT-1 BR - PT-1 GLAZ P PT-1 BR - PT-1 GYP EFS EFS-1 12'-0" 6
119 LOBBY CONC POL PC-1 - - - - - - - - - - - - - - - - - - - 4, 10, 12
120 WELLNESS ROOM CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 11
121 SEATING CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
122 RECRUITING OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11
123 RETENTION OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
124 RETENTION OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11
125 TABLES AND CHAIRS STORAGE CONC SEAL SC-1 CMU RB RB-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 11
126 CUSTODIAL CONC RES RES-1 CMU/GYP RES RESB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 15
127 SCULLERY CONC RES RES-1 CMU RES RESB-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 GYP EFS EFS-1 9'-0" 6, 13
128 SERVERY CONC RES RES-1 CMU/GYP RES RESB-1 CMU PT PT-1 - - PT-1 GYP PT PT-1 CMU PT PT-1 GYP EFS EFS-1 9'-0" 6, 13
129 KITCHEN CONC RES RES-1 CMU/GYP RES RESB-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 CMU PT PT-1 GYP EFS EFS-1 9'-0" 6, 13
130 DRY STORAGE CONC RES RES-1 CMU/GYP RES RESB-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 GYP EFS EFS-1 9'-0" 6, 13
131 TOILET CONC RES RES-1 CMU/GYP RES RESB-1 GYP CWT CWT-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-1 GYP EFS EFS-1 9'-0" 6, 13
132 ASSEMBLY HALL CONC SEAL SC-1 CMU RB RB-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 11, 14
133 GENERAL PURPOSE TRAINING BAYS CONC SEAL SC-1 CMU - - CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 9, 5
134 VESTIBULE CONC REM REM-1 CMU RB RB-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 GYP EFS EFS-1 9'-0" 5, 12
135 SUPPLY AFF CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 1
136 STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 1, 7
137 SUPPLY SGT CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 1
138 VESTIBULE CONC SEAL SC-1 CONC, GYP RB RB-1 CONC PT PT-1 GYP PT PT-1 GYP PT PT-1 - - PT-1 EXP PT PT-2 VARIES 1, 11
139 VAULT CONC SEAL SC-1 CONC - - CONC PT PT-1 CONC PT PT-1 CONC PT PT-1 CONC PT PT-1 CONC PT PT-2 8'-8"
140 UNIT STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 CMU PT PT-1 CONC/ GYP PT PT-4 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1
141A UNHEATED STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 CMU PT PT-1 GYP PT PT-1 CMU PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4, 9
141B UNHEATED STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4, 9
142 FIRE PUMP ROOM CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 4, 9
143 MECHANICAL CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 4, 9
144 MAIL VESTIBULE CONC SEAL SC-1 CMU - - CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 9
145 MAIL ROOM CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 9
146 MAIL PICK UP CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1
147A UNIT LOCKERS CONC SEAL SC-1 CMU/GYP RB RB-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 9
147B UNIT LOCKERS CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 9
147C UNIT LOCKERS CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1, 9
148 PHYSICAL FITNESS CONC RAF RAF-1 CMU/GYP RB RB-1 GYP PT PT-1 CMU PT PT-1 CMU PT PT-3 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4
149 TELECOM EQUIPMENT CONC ESD ESD-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 9'-0" 1, 3
150 MENS SHOWERS CONC CFT CFT-1 CMU/GYP CWB CWB-1 GYP CWT CWT-1 GYP CWT CWT-1 CMU CWT CWT-1 CMU PT CWT-1 GYP EFS EFS-1 9'-0" 2, 6, 10
151 CUSTODIAL CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1
152 MENS TOILET CONC SEAL SC-1 CMU/GYP CWB CWB-1 GYP PT/CWT PT-4, CWT-1 GYP CWT CWT-1, CWT-2 CMU CWT CWT-1 GYP CWT CWT-1 GYP EFS EFS-1 9'-0" 2, 6, 10, 11
153 WOMENS TOILET CONC SEAL SC-1 CMU/GYP CWB CWB-1 GYP PT/CWT PT-4, CWT-1 GYP CWT CWT-1 CMU CWT CWT-1 GYP CWT CWT-1, CWT-2 GYP EFS EFS-1 9'-0" 2, 6, 10, 11
154 ELECTRICAL CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 11
155 WOMENS SHOWERS CONC CFT CFT-1 GYP CWB CWB-1 GYP CWT CWT-1 GYP PT CWT-1 GYP CWT CWT-1 GYP CWT CWT-1 GYP EFS EFS-1 9'-0" 2, 6, 10
156 STAIRS CONC SEAL, RTR SC-1, RTR-1 CMU/GYP RB RB-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1
157 STAIRS CONC SEAL, RTR SC-1, RTR-1 CMU/GYP RB RB-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VARIES 1
158A CORRIDOR CONC POL PC-1 CMU/GYP RB RB-1 GYP PT PT-1 - - PT-1 GYP PT PT-1 CMU PT PT-1 - APC APC-1 9'-0" 4, 12
158B CORRIDOR CONC POL PC-1 CMU/GYP RB RB-1 - - PT-1 CMU PT PT-1 CMU PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 4, 12, 14
159 STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
160 ELEVATOR CONC - - - - - CMU - - CMU - - CMU - CMU - - EXP - - VARIES
166 RECYCLE STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 CMU/ GYP PT PT-1 EXP PT PT-2 VARIES 4, 9
SECOND FLOOR
201 S2 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 11
202 S2 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 11
203 S2 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
204 S6 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11
205 S6 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
206 S4 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11
207 S4 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
208 CHAP OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11
209 OPEN OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
210 S1 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11
211 S1 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
212 S1 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11
213 PRINT ROOM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11
214 S3 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0" 11
215 ADMINISTRATION CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 10'-0" 11
216 S3 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
217 S3 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 11
218 S3 OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 - APC APC-1 9'-0" 11
219 AO OFFICE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
220 O5 COMMANDER OFFICE CONC CPT CPT-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0"
221 X0 OFFICE CONC CPT CPT-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0"
222 BATTALION COMMAND CONC CPT CPT-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0"
223 CMD SGT MJ OFF CONC CPT CPT-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 9'-0"
224 COMMAND CONFERENCE ROOM CONC CPT CPT-1 GYP RB RB-1 GYP PT PT-1 GYP DEW DEW-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0"
225 STORAGE CONC VCT VCT-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0"
226 STORAGE CONC VCT VCT-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0"
227 CUSTODIAL CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 4
228 WOMENS TOILET CONC SEAL SC-1 CMU/GYP CWB CWB-1 GYP PT/CWT PT-3, CWT-1 CMU PT PT-3 CMU CWT CWT-1 GYP CWT CWT-1 GYP EFS EFS-1 9'-0" 2, 6, 10, 11
229 MENS TOILET CONC SEAL SC-1 CMU/GYP CWB CWB-1 GYP PT/CWT PT-3, CWT-1 GYP CWT CWT-1 CMU CWT CWT-1 GYP PT PT-3 GYP EFS EFS-1 9'-0" 2, 6, 10, 11
230 FACILITY STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 EXP PT PT-2 VARIES 1, 4, 7
231 BREAK ROOM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-3 GYP PT PT-4 CMU PT PT-4 - - - - APC APC-1 9'-0" 11
232 ELECTRICAL CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 11
233 TELECOM EQUIPMENT CONC ESD ESD-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 3, 11
234 BREAK OUT ROOM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-3 - - - GYP PT PT-4 GYP DEW DEW-1 - APC APC-1 9'-0" 11
235 CURRENT OPERATIONS CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-4 GYP DEW DEW-1 GYP PT PT-1 GYP DEW DEW-1 - APC APC-1 10'-0" 11
236 AUDITORIUM CONC SEAL SC-1 GYP RB RB-1 GYP DEW DEW-1 GYP DEW DEW-1 GYP PT PT-1 GYP DEW DEW-1 - APC APC-1 10'-0" 11
237 ELECTRICAL CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 1
238 TA STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 1, 4
239 TA STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 1, 4
240 TA STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 1, 4
241 AV CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 8'-0" 1, 7
242 PHYSICIAN ASSISTANT CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-4 - APC APC-1 8'-0" 11
243 PA STORAGE CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 1, 4, 7, 11
244 EXAM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-4 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
245 MEDICAL EXAM CONC SEAL SC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 11
247 CORRIDOR CONC POL PC-1 GYP RB RB-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 GYP PT PT-1 - APC APC-1 9'-0" 4, 11
248 STORAGE CONC SEAL SC-1 CMU/GYP RB RB-1 GYP PT PT-1 CMU PT PT-1 GYP PT PT-1 CMU PT PT-1 EXP PT PT-2 VAIRES 1
1 ADDENDUM 1 08/16/17
1. DOOR DETAILS ARE ON DRAWINGS A-603 THRU A-607 UNLESS OTHERWISE NOTED.
2. ALL WOOD DOORS SHALL BE PREFINISHED - REFER TO SPECIFICATIONS.
3. ALL STEEL DOORS AND FRAMES SHALL BE PAINTED.
4. DO NOT PAINT LABELS OF TESTING AGENCY ON FIRE-RATED DOORS AND FRAMES.
5. ALL EXTERIOR STEEL DOORS AND FRAMES SHALL BE GALVANIZED. SOME INTERIOR
DOORS AND FRAMES ARE GALVANIZED. REFER TO DOOR SCHEDULE. WIPE COAT
GALVANIZED STEEL IS NOT ACCEPTABLE.
6. ALL FIRE-RATED DOORS SHALL BE SELF-CLOSING AND SELF-LATCHING.
7. FIRE DOORS AND FRAMES SHALL HAVE AN APPROVED LABEL OR LISTING MARK
INDICATING THE FIRE-PROTECTION RATING, WHICH IS PRIMARILY AFFIXED AT THE
FACTORY WHERE FABRICATION AND ASSEMBLY ARE PERFORMED.
8. FIRE-RATED DOOR FRAMES SHALL BE INSTALLED STRICTLY PER MANUFACTURER'S
PRINTED INSTRUCTIONS. MANUFACTURER'S PRINTED INSTRUCTIONS SHALL BE MADE
AVAILABLE TO THE INSPECTION AUTHORITY.
9. ALL EXTERIOR DOORS SHALL BE INSULATED.
10. IF PAVEMENT ON EXTERIOR SIDE OF MAN DOORS IS NOT INDICATED AND DETAILED BY
CIVIL - REFER TO A2 / A-605 OR B2 / A-605.
11. ALL EXIT DOOR HARDWARE SHALL ALLOW DOORS TO BE OPENED IN THE DIRECTION OF
EXIT WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.
12. THE MAXIMUM EXTERIOR DOOR OPENING EFFORTS SHALL NOT EXCEED 8.5 POUNDS.
13. BOTH THE LATCHING AND DEAD BOLT DEVICES ON EXTERIOR DOORS SHALL RELEASE
WITH A SINGLE ACTION OF THE INSIDE LEVER.
14. HINGES FOR OUT-SWINGING EXTERIOR DOORS SHALL BE EQUIPPED WITH NON-
REMOVABLE HINGE PINS IF NOT SCHEDULED TO RECEIVE CONTINUOUS HINGE.
15. REMOVABLE GLAZING STOPS AT BORROW LITES SHALL BE INSTALLED ON SECURE SIDE.
16. DO NOT CAULK BACK BEND STEEL DOOR FRAMES TO GYPSUM BOARD PARTITIONS.
17. THE DOOR FRAME MANUFACTURER SHALL VERIFY ACTUAL WALL / PARTITION THICKNESS
WITH CONTRACTOR PRIOR TO FABRICATION OF DOOR FRAMES.
18. REFER TO SPECIFICATIONS FOR HARDWARE GROUPS.
19. AT ALL EXTERIOR DOORS IN CMU, CONTINUE FLUID APPLIED AIR BARRIER ONTO JAMB
BLOCK TO BE COVERED BY DOOR FRAME.
DOOR SCHEDULE GENERAL NOTES
1. GALVANIZED DOOR AND FRAME
2. INSULATED DOOR
3. UNDERCUT DOOR 3/4" COORDINATE BOTTOM/UNDERCUT OF DOORS WITH FINISH
MATERIALS, THRESHOLDS, ETC.
4. SMOKE SEALED DOOR (HEAD AND JAMBS ONLY)
5. GALVANIZED FRAME
6. ELECTRIC POWERED DOOR
7. OVERHEAD COILING DOOR SIZE AND COILING COUNTER DOOR SIZE INDICATED IS FOR
FINISHED OPENING. ACTUAL DOOR SIZE WILL BE LARGER BASED ON
MANUFACTURER'S STANDARDS.
8. CERAMIC TILE SHALL BE FIT TO DOOR FRAME.
9. PREFINISHED DOOR
10. POWER-ASSISTED ENTRANCE DOOR ON RIGHT HAND REVERSE.
11. PREPARE DOOR AND FRAME FOR BALANCED MAGNETIC SWITCH - REFER TO C1/A-603
12. PROVIDE COAT HOOK CENTERED ON BACK SIDE OF DOOR AT 5'-6" AFF
13. CARD READER WITH KEYPAD
14. ELECTRIFIED LOCK WITH 120V POWER SUPPLY (RHR)
15. VAULT DOOR - REFER TO A4 / A-606
16. FOR DETAIL OF KEYED REMOVABLE MULLION REFER TO B4 / A-606
17. DOOR AND FRAME ARE PART OF BLAST-RESISTANT EXTERIOR FACADE - REFER TO
SPECIFICATION SECTION 089500
18. DOOR AND FRAME ARE INCLUDED IN ABI.
19. IN ABI CHANGE HEAD DETAIL TO D1 / A-606, CHANGE JAMB DETAIL TO C1 / A-606, AND
CHANGE SILL DETAIL TO B1 / A-606. CHANGE DOOR AND FRAME TO 90 MINUTE FIRE
RATING.
20. IN ABI CHANGE HEAD DETAIL TO B3 / A-606, CHANGE JAMB DETAIL TO A3 / A-606, AND
CHANGE SILL DETAIL TO B1 / A-606.
21. MANUFACTURER'S STANDARD HEAD DETAIL.
22. DOOR THICKNESS SHALL BE AS REQUIRED BY MANUFACTURER TO ACCOMODATE
GLASS TYPE INDICATED.
23. DOOR THICKNESS PER MANUFACTURER.
DOOR SCHEDULE REMARKS
ALUM ALUMINUM
HM HOLLOW METAL
MFR HARDWARE BY DOOR
MANUFACTURER
STL STEEL
SS STAINLESS STEEL
WD SOLID CORE WOOD
1/4" CLEAR TEMPERED (PROVIDE FIRE RATED
GLASS IN NARROW LITE DOORS)
DOOR SCHEDULE LEGEND
GLASS TYPE SCHEDULE
G1
G2
G3
G4
G5
G6
G7
1/4" CLEAR LAMINATED
1 1/4" TINTED INSULATED
1 1/4" SPANDREL INSULATED
1 1/4" CLEAR INSULATED (SAFETY APPLICATION)
1 1/4" TINTED INSULATED (SAFETYAPPLICATION)
1 1/2" TINTED INSULATED
SCHEDULED DOOR
D
IM
E N
S
IO
N E
N
LA
R G
E D
F O
R C
LA
R
IT
Y
3/ 8"
M A
X
IM
U M
4"MAXIMUM
4 7/8"
4 1/8"
STANDARD ANSI
CUTOUT FOR MORTISE
INSTALLATION
HIGH SECURITY
CONCEALED MAGNETIC
CONTACT
HIGH SECURITY
CONCEALED MAGNETIC
CONTACT
STANDARD ANSI
CUTOUT FOR MORTISE
INSTALLATION
SCHEDULED DOOR
FRAME
2" 2"
4" R
E F
E R
T O
S C
H E
D U
LE
DOOR FRAME
FINISH FLOOR
2"
2"4" R
E F
E R
T O
S C
H E
D U
LE DOOR FRAME
FINISH FLOOR
1' - 6" 2"
2"
4" R
E F
E R
T O
S C
H E
D U
LE
DOOR FRAME
FINISH FLOOR
2"
KEYED
REMOVABLE
MULLION
G1
NOTE: FOR STOREFRONT
DOOR FRAMES REFER TO A-604
4"
REFER TO
SCHEDULE
REFER
TO SCHEDULE
REFER TO
SCHEDULE
2" 2"
2" R
E F
E R
T O
S C
H E
D U
LE
DOOR FRAME
FINISH FLOOR
2"
2" R
E F
E R
T O
S C
H E
D U
LE
DOOR FRAME
FINISH FLOOR
2"
KEYED
REMOVABLE
MULLION
REFER
TO SCHEDULE
REFER TO
SCHEDULE
2"
2"2" R
E F
E R
T O
S C
H E
D U
LE DOOR FRAME
FINISH FLOOR
1' - 6"
2"
G1
4"
REFER TO
SCHEDULE
2"
2"2" R
E F
E R
T O
S C
H E
D U
LE
FINISH FLOOR
1' - 0" 2"
4"
REFER TO
SCHEDULE
2" 2"
3'
2" 4'
0"
G1
2" 3' - 8" 2"
2" 2"
2'
0" 6'
0"
G2
2" 5' - 0" 2"
D3/D4
A-606
B3
A-605
B4
A-605
B4
A-605
B4
A-605
B3
A-605
DOOR FRAME
G1
B3
A-605
D4
A-605
B1
A-605
C4
A-605
B2
A-607
B4
A-607
A2
A-607
OPPOSITE
D4
A-605
D4
A-605
FLUSH DOOR
FLUSH PANEL
DOOR - REFER
TO SCHEDULE
FOR MATERIAL
FOVERHEAD COILINGOH
PREFINISHED
SLATS
REFER
TO SCHEDULE
R E
F E
R T
O S
C H
E D
U
LE
REFER
TO SCHEDULE
R E
F E
R T
O S
C H
E D
U
LE
FULL GLASS
GLASS:
TYPE AS
SCHEDULED
FG
3 1/2"
1/
2"
NARROW LITE
GLASS:
TYPE AS
SCHEDULED
NL
3/
4"
FLUSH PANEL
DOOR - REFER
TO SCHEDULE
FOR MATERIAL
6"4"
REFER TO
SCHEDULE
2'
1"
R E
F E
R T
O S
C H
E D
U
LE
REFER
TO SCHEDULE
R E
F E
R T
O S
C H
E D
U
LE
VAULT DOOR
HIGH SECURITY
ELECTOMECHANICAL
LOCK FOR VAULT
DOOR UL GROUP
V
R E
F E
R T
O S
C H
E D
U
LE
COILING COUNTERCC
S C
H E
D U
LE
R E
F E
R T
O
SCHEDULE
REFER TO
REFER
TO SCHEDULE
FINISH FLOOR
PREFINISHED
SLATS
SECURITY MESH
DUTCH
SM
R E
F E
R T
O S
C H
E D
U
LE
REFER
TO SCHEDULE
GLASS:
TYPE AS
SCHEDULED
FGI
1/
2"
3 1/2"
REFER TO
SCHEDULE
R E
F E
R T
O S
C H
E D
U
LE
DOOR SCHEDULE
D
C
B
A
1 2 3 4 5
BID FINAL SUBMITTAL
Designed:
Drawn :
Checked:
Drawing No.:
Date:
Drawing Title:
Scales:
P R
O J E
C T
N O
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
N A
T
IO
N A
L G
U A
R D
R E
A D
IN
E
S S
C E
N T
E R
N O
R T
H C
A R
O L
IN
A
A R
M Y
N A
T
IO
N A
L G
U A
R D
03 APRIL 2017
DATEREV DESCRIPTION
501 North Broadway, Saint Louis, Missouri 63102
DISCLAIMER
ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE
ONLY FOR THE PURPOSE OF AUTHENTICATING THIS
DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS
RELATING TO THIS PROJECT IS DISCLAIMED
NC Engineering Firm License No. F-0287 NC Architectural Firm No. 50757
B
IM
/U
S
N o rt h C a ro lin a A rm y N a ti o n a l G u a rd
F W
/N
C A
R N
G R e a d in e s s C e n te r_ A
R C
H V
.r v t
/1
/2
:0 :5
P
M
A-603DEF
JAD
AJT
ARCHITECTURAL
DOOR SCHEDULE, TYPES,
AND DETAILS
DOOR
NO.
DOOR FRAME
FIRE RATING REMARKSTYPE MATERIAL GLAZING SIZE: WIDTH x HEIGHT THICKNESS TYPE MATERIAL HEAD DETAIL JAMB DETAIL SILL DETAIL
101A F HM - 4'-0" X 7'-0" 1 3/4" 1 HM D4 / A-607 C4 / A-607 A4 / A-605 - 1, 2, 17
101B F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 5, 9
102 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9
103 F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 4
104 F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 4
105 F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 4
106A F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9
106B F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9
107 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9
108 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9
109 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9
111 F WD - 3'-0" X 7'-0" 1 3/4" 1 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9
112 F WD - 3'-0" X 7'-0" 1 3/4" 7 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12
113 F WD - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12
114 F WD - 3'-0" X 7'-0" 1 3/4" 7 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12
115 F WD - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9
116 F WD - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12
117 FG ALUM G1 3'-0" X 7'-0" 1 3/4" B5 / A-610 ALUM B3 / A-557 C1 / A-557
C2 / A-557
A5 / A-605 - 23
118A FG ALUM G3 PR 3'-0" X 7'-0" - W5 / A-610 ALUM D5 / A-557 D1 / A-557
D3 / A-557
B1 / A-606 - 2, 10, 16, 23
118B FG ALUM G3 PR 3'-0" X 7'-0" - W5 / A-610 ALUM D5 / A-557 D1 / A-557
D3 / A-557
B1 / A-606 - 2, 16, 23
118C FG ALUM G4 PR 3'-0" X 7'-0" - W6 / A-610 ALUM D5 / A-557 D1 / A-557
D3 / A-557
A1 / A-606 - 2, 10, 11, 14, 16, 23
118D FG ALUM G4 PR 3'-0" X 7'-0" - W6 / A-610 ALUM D5 / A-557 D1 / A-557
D3 / A-557
A1 / A-606 - 2, 16, 23
120 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A4 / A-605 - 9, 12
121 F WD - 3'-0" X 7'-0" 1 3/4" 3 HM B2 / A-511 A4 / A-607 A5 / A-605 - 9
122 F WD - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12
123 F WD - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12
124 F WD - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 12
125 F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D1 / A-606 C1 / A-606 A5 / A-605 - 4
126 F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D1 / A-605 C1 / A-605 A5 / A-605 - 1
127 CC SS - 4'-0" X 3'-10" - - - B4 / A-511
SIMILAR
B2 / A-606 A1 / A-607 - 7, 23
128A F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D1 / A-606 C1 / A-606 A5 / A-605 - 1
128B F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D1 / A-606 C1 / A-606 A5 / A-605 - 1
130 F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 17
131 F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D1 / A-605 C1 / A-605 A5 / A-605 - 1
132A F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17
132B F HM PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17, 18, 19
132C F WD - PR 6'-0" X 7'-0" 1 3/4" 2 HM D1 / A-606 C1 / A-606 A4 / A-605 45 MIN 9, 16
132D F WD - PR 6'-0" X 7'-0" 1 3/4" 2 HM D1 / A-606 C1 / A-606 A4 / A-605 45 MIN 9, 16
132E OH SS - 6'-0" X 8'-0" - - - B4 / A-511 B2 / A-606 A2 / A-606 45 MIN 7, 23
133A F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 17, 18
133B OH ALUM - 16'-0" X 16'-0" - - STEEL D3 / A-607 C3 / A-607 A3 / A-605 - 2, 6, 7, 17, 18, 23
133C F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D1 / A-606 C1 / A-606 B1 / A-606 90 MIN 1, 2, 18
133D OH ALUM - 16'-0" X 16'-0" - - STEEL D3 / A-607 C3 / A-607 A3 / A-605 - 2, 6, 7, 17, 18, 23
133E F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 17, 18
134 F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17, 18
135A F HM - 3'-0" X 7'-0" 1 3/4" 6 HM D5 / A-605 C5 / A-605 A5 / A-605 - 1
135B - - - - - 8 HM D4 / A-605 C4 / A-605 B1 / A-605 - 5
135C - - - - - 8 HM D4 / A-605 C4 / A-605 B1 / A-605 - 5
135D - - - - - 8 HM D4 / A-605 C4 / A-605 B1 / A-605 - 5
136 F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 4, 5
137A F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 - 5, 12
137B - - - - - 8 HM D4 / A-605 C4 / A-605 B1 / A-605 - 5
137C - - - - - 8 HM D4 / A-605 C4 / A-605 B1 / A-605 5
138 F HM - PR 3'-0" X 7'-0" 1 3/4" 5 HM D5 / A-605 C5 / A-605 A5 / A-605 90 MIN 11, 16
139 V STL - AS NOTED 3 1/4" - STL D5 / A-606 C5 / A-606 B5 / A-606 - 15
140A F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17
140B SM STL - PR 6'-0" X 7'-0" - - STL - C2 / A-554 D3 / A-555
SIMILIAR
- 21
141A F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17
141B F WD - PR 3'-0" X 7'-0" 1 3/4" 5 HM B5 / A-607 A5 / A-607 A5 / A-605 90 MIN 4, 9, 16
142 F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17
143A F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17
144 F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D4 / A-607 C4 / A-607 A4 / A-605 - 1, 2, 17
145A F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D3 / A-606 A3 / A-606 A5 / A-605 - 1
145B F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9
146 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9
147A F HM - PR 6'-0" X 7'-0" 1 3/4" 2 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 16, 17
147B F WD - PR 3'-0" X 7'-0" 1 3/4" 5 HM B5 / A-607 A5 / A-607 A5 / A-605 90 MIN 4, 9, 16
147C F WD - PR 3'-0" X 7'-0" 1 3/4" 5 HM B5 / A-607 A5 / A-607 A5 / A-605 90 MIN 4, 9, 16
148 F WD - PR 3'-0" X 7'-0" 1 3/4" 5 HM D5 / A-605 C5 / A-605 A5 / A-605 - 9, 16
149 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9
150 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D3 / A-605 C3 / A-605 A4 / A-552 - 8, 9
151 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9
154 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9
155 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D3 / A-605 C3 / A-605 A4 / A-552 - 8, 9
156A F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D4 / A-607 C4 / A-607 A4 / A-605 - 1, 2, 17
156B F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 45 MIN 9
156C NL WD GI 3'-0" X 7'-0" 1 3/4" 1 HM D2 / A-605 C2 / A-605 A3 / A-605 45 MIN 9
157A F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D2 / A-607 C1 / A-607 AND
C2 / A-607
A4 / A-605 - 1, 2, 17
157B F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D5 / A-605 C5 / A-605 A5 / A-605 45 MIN 9
157C NL WD GI 3'-0" X 7'-0" 1 3/4" 1 HM D2 / A-605 C2 / A-605 A5 / A-605 45 MIN 9
158A FG1 HM G6 PR 3'-0" X 7'-0" 1 3/4" 2 HM A1 / A-511 B1 / A-541 A4 / A-605 - 1, 2, 11, 14, 16, 17, 22
158B F HM - 3'-0" X 7'-0" 1 3/4" 1 HM D5 / A-607 C5 / A-607 A4 / A-605 - 1, 2, 17, 18, 20
159 F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-606 C2 / A-606 A5 / A-606 - 9
166A F WD - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 9, 4
166B F HM - 3'-0" X 7'-0" 1 3/4" 4 HM D2 / A-605 C2 / A-605 A5 / A-605 - 1, 4
3" = 1'-0"C1
DETAIL
1/4" = 1'-0"A1
FRAME TYPES
1/4" = 1'-0"B1
DOOR TYPES
1/4" = 1'-0"
2' 4' 8' 12'
- FIRST FLOOR
NOT TO SCALE
A-603
EVACUATION PLAN
Evacuation Instructions
Legend
FLOOR PLAN
DRAWN TO SCALE
FLOOR SPECIFIC
EVACUATION INSTRUCTIONS
THAT MEET LOCAL FIRE CODE,
BUILDING CODE, AND NCARNG
REQUIREMENTS
LEGEND SHALL INCLUDE BUT
NOT BE LIMITED TO; VIEW
LOCATION ICON, PRIMARY
EXIT ROUTE, SECONDARY EXIT
ROUTE, FIRE EXTINGUISHER,
EMERGENCY SHOWER/EYE
WASH STATION, AND AED
NOTE:
VERIFY DESIGN AND
LOCATION OF EVACUATION
PLANS WITH NCARNG
EVACUATION PLAN IN
ALUMINUM FRAME WITH
NON-GLARE SHATTER-PROOF
COVER
17"
FIRE ALARM
1/8" THICK PAINTED
ALUMINUM SIGN
MECHANICALLY APPLIED
EXTERIOR SIGN PANEL
WHITE TYPE STYLE ON
PANTONE 18-0601 TPX
CHARCOAL GRAY
BACKGROUND
SPRINKLER
WHEN BELL RINGS
CALL 911
2' - 0"
1'
6"
2" 2"
NOTES:
1. SIGN SHALL BE ACRYLIC
2. PROVIDE 1/32" HIGH RAISED CHARACTERS
3. SANS SERIF TYPE STYLE
4. CHARACTER SHALL BE WHITE ON PANTONE 18-1222 TPX
NUTMEG BROWN BACKGROUND
5. ON GLASS APPLICATIONS PROVIDE BLANK COVERS ON
OPPOSITE SIDE
6. CENTER SIGN ON DOOR
GRADE 2 BRAILLE
5' -0
A
F F
2" 3"
1"
6"
9"
MEN WOMEN
BLUE FIELD 1/4" THICK,
TYPICAL
WHITE GRAPHICS AND
TYPE STYLE RAISED 1/32",
TYPICAL
GRADE 2 BRAILLE
MEN WOMEN
NOTES:
1. PROVIDE APPROPRIATE GEOMETRIC SYMBOL LOCATED ON THE PARTITION
ADJACENT TO THE LATCH SIDE THE ENTRANCE DOOR AT A HEIGHT OF 60" TO
THE CENTER OF THE SYMBOL. THE COLOR AND CONTRAST OF THE SYMBOL
SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR OF THE DOOR.
2. SIGN SHALL BE ACRYLIC.
3. PROVIDE 1/32" HIGH RAISED CHARACTERS AND SYMBOLS.
4. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, PLACE SIGN ON THE
NEAREST ADJACENT WALL. LOCATE SIGNS SO THAT A PERSON MAY
APPROACH WITHIN 3 INCHES OF SIGNAGE WITHOUT ENCOUNTERING
PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR.
5. SANS SERIF TYPE STYLE.
6. MINIMUM GRAPHICS HEIGHT 3".
TYPICAL
6" MINIMUM
T Y
P
IC
A L
6" M
IN
IM
U M
PROVIDE DIRECTIONAL
ARROWS AS REQUIRED,
TYPICAL
1/8" THICK PAINTED
ALUMINUM SIGN
MECHANICALLY APPLIED
INTERIOR SIGN PANEL
WHITE TYPE STYLE ON
PANTONE 18-0601 TPX
CHARCOAL GRAY
BACKGROUND
INSTALLING CONTRACTOR
SHALL FILL IN VALUES
INCLUDING NAME OF
INSTALLING CONTRACTOR
2. RESIDUAL PRESSURE
AT THE BASE OF THE
RISER
3. STATIC PRESSURE
1. WATER FLOW RATE
SYSTEM DEMAND
2. DESIGNED AREA
OF DISCHARGE
1. DENSITY
THIS BUILDING IS PROTECTED A
HYDRAULICALLY DESIGNED
AUTOMATIC SPRINKLER SYSTEM
NO. OF SPRINKLERS
BASIS FOR DESIGN
LOCATION
HYDRAULIC SYSTEM
OCCUPANCY
CLASSIFICATION
4. HOSE STREAM
ALLOWANCE
NOTE: SIGN SHALL COMPLY
WITH 2016 NFPA 13.25.5
SMOKING
PROHIBITED WITHIN
50 FEET OF THE
BUILDING PERIMETER
WHITE TYPE STYLE ON
PANTONE 18-0601 TPX
CHARCOAL GRAY
BACKGROUND
1/8" THICK
PAINTED
ALUMINUM SIGN
MECHANICALLY
FASTENED
EXTERIOR SIGN
1'
4" 1' - 4"
THIS IS A NON-SMOKING FACILITY
PLAN VIEW
ELEVATION VIEW
7’ -0
A
F F
NOTES:
SIGN BASIS OF DESIGN MANUFACTURER: Safehouse Signs, Inc. (OR APPROVED EQUAL)
AT FIRE EXTINGUISHERS: PRODUCT - PWS 4
AT AED: PRODUCT - PWS 100
PARTITION
6” H x 12” W x 1/8” THICK VINYL
PROJECTING PARTITON SIGN
CENTER ON FIRE EXTINGUISHER,
FIRE PROTECTION CABINET, OR
FIRE ALARM PULL STATION BELOW
FASTENING:
USE MANUFACTURER'S
RECOMMENDED TAPE AND
SCREWS WITH WASHERS
FASTENING METHOD
ROOM IDENTIFICATION SIGN:
FOR PRIVATE OFFICES, SIGN MESSAGE
SHALL BE 6" - 7" TYPE WRITTEN INSERT
SAN SERIF TYPE STYLE
NCARNG
WHITE TYPE STYLE ON
PANTONE 18-0601 TPX
CHARCOAL GRAY
BACKGROUND
1/2" 1/2"
7"
3/ 4"
5/ 8"
5/ 8"
5/ 8"
1/ 2"
1/ 2"
7"
OFFICE
1/
2"
RADIUS ALL CORNERS
SIGNAGE GENERAL NOTES
1. DRAWING INDICATES DESIGN INTENT ONLY.
2. ALL ROOM SIGNAGE NUMBERS SHALL BE EXACTLY THE SAME AS THOSE INDICATED ON THE
PLANS WITHOUT EXCEPTION.
3. LEGEND SYMBOLS INDICATE LOCATION OF A SIGN. FINAL LOCATION SHALL BE FIELD
COORDINATED WITH ARCHITECT AND NORTH CAROLINA ARMY NATIONAL GUARD.
4. SIGNAGE CONTRACTOR SHALL BE RESPONSIBLE FOR THE FABRICATION AND INSTALLATION
OF ALL SIGNS AND SHALL BE RESPONSIBLE FOR THE DESIGN AND ENGINEERING OF ALL
STRUCTURAL, ATTACHMENT, ANCHORING, AND FOUNDATION FEATURES UNLESS
OTHERWISE NOTED.
5. SIGNAGE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL
CONDITIONS RELATED TO THE INSTALLATION OF SIGNS.
6. ALL HARDWARE AND FASTENERS SHALL BE CONCEALED UNLESS OTHERWISE NOTED.
FINISH ALL EXPOSED HARDWARE AND FASTENERS TO MATCH SUPPORTING SIGN SURFACES
(COLOR) UNLESS OTHERWISE NOTED.
7. SIGNAGE SHALL BE MOUNTED ON LATCH SIDE OF DOORS UNLESS OTHERWISE INDICATED.
REFER TO D4 / G-120. SIGNAGE DESIGNATED TO BE ACCESSIBLE SHALL COMPLY WITH THE
CURRENT ADAAG STANDARDS.
8. "*" ON SIGNAGE SCHEDULE INDICATED SIGN IN ACCESSIBLE AREA AND SHALL INCLUDE
GRADE 2 BRAILLE.
9. FOR ADDITIONAL REQUIREMENTS OF SIGNS ON IDENTIFICATION REFER TO G-120.
10. FOR ILLUMINATED EXIT SIGNS REFER TO ELECTRICAL DRAWINGS.
11. PROJECTING AND OVERHEAD SIGNS SHALL COMPLY WITH DETAIL A4 / G-120.
12. PROVIDE SIGN ABOVE BRACKET-MOUNTED FIRE EXTINGUISHERS - REFER TO B3 / A-713.
REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF FIRE EXTINGUISHERS.
13. PROVIDE SIGN ABOVE AUTOMATIC EXTERNAL DEFIBRILLATOR - REFER TO B3 / A-713.
14. ALL ROOM SIGNS OF TYPE 'RI' SHALL HAVE A THREE-DIGIT ROOM NUMBER IN ADDITION TO
THE ROOM NAME.
15. PRIVATELY OCCUPIED ROOMS SHALL HAVE A REMOVABLE NAME TAG FOR OCCUPANT -
COORDINATE NAME WITH NORTH CAROLINA ARMY NATIONAL GUARD.
16. ALL REMOVABLE NAME TAGS SHALL BE SUCH THAT NORTH CAROLINA ARMY NATIONAL
GUARD CAN PRINT / CHANGE WITHOUT SPECIAL EQUIPMENT.
17. FOR SITE AND TRAFFIC SIGNAGE REFER TO CIVIL DRAWINGS.
18. FOR BUILDING IDENTIFICATION SIGN AT ROADWAY REFER TO LANDSCAPE DRAWINGS.
19. SIGNS ON SYSTEMS FURNITURE WILL BE GFGI. SYSTEMS FURNITURE IS NOT IN CONTRACT.
20. FOR ELEVATOR RELATED SIGNAGE REFER TO ELEVATOR SPECIFICATION.
ROOM
NAME
1' - 4"
1'
4"
1/8" THICK PAINTED
ALUMINUM SIGN
MECHANICALLY APPLIED
EXTERIOR SIGN PANEL
WHITE SANS SERIF TYPE STYLE
ON PANTONE 18-0601 TPX
CHARCOAL GRAY BACKGROUND.
CENTER TEXT HORIZONTALLY
AND VERTICALLY. REFER TO 'IN'
TYPE SIGN KEY FOR ROOM NAME
E Q
E Q
1' - 4"
1'
4"
1/8" THICK PAINTED
ALUMINUM SIGN
MECHANICALLY APPLIED
INTERIOR SIGN PANEL
WHITE SANS SERIF TYPE STYLE
ON PANTONE 18-0601 TPX
CHARCOAL GRAY BACKGROUND.
MAXIMUM
OCCUPANCY
REFER TO LIFE SAFETY PLANS
FOR MAXIMUM OCCUPANT LOAD
FIRST FLOOR
EL: 100' - 0"
9'
0" 8"
7" 6"
EQUAL EQUAL
8'
0"
EQUALEQUAL
9" ARIAL TEXT SHALL
BE ALUMINUM
6" ARIAL TEXT SHALL
BE ALUMINUM
8'-0" DIAMETER
LOGO (GFGI)
SIGNAGE FINISH SHALL
MATCH BLACK SEMI-GLOSS
20059, PMS 476.
D2
A-713
3" FORMED METAL PANELS
(MP1)
1 1/2" THERMAL INSULATION
CMU
PIN MOUNTED DIMENSIONAL
LETTER SIGNAGE. DRILL AND SET
INTO CMU PER MANUFACTURER'S
RECOMMENDATIONS - SEAL
TIGHT PENETRATIONS OF
FORMED METAL PANELS
PANTONE 18-0601 TPX CHARCOAL
GRAY BACKGROUND ON 1/4" THICK
ALUMINUM WALL MOUNTED SIGN.
2" 2"
3' - 4"
2" 2"
1'
0"
WHITE REFLECTIVE LETTERS
AND NUMBERS IN 12" ARIAL
BOLD, CENTERED ON SIGN,
COMLIANT WITH AR 420-70.
NOTES:
1. PRIOR TO FABRICATION CONFIRM BUILDING NUMBER WITH NORTH
CAROLINA ARMY NATIONAL GUARD.
2. EXTERIOR SIGN PANEL. MECHANICALLY APPLIED TO BRICK VENEER.
3. FOR MOUNTNG HEIGHT REFERENCE EXTERIOR ELEVATIONS.
D
C
B
A
1 2 3 4 5
BID FINAL SUBMITTAL
Designed:
Drawn :
Checked:
Drawing No.:
Date:
Drawing Title:
Scales:
P R
O J E
C T
N O
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
N A
T
IO
N A
L G
U A
R D
R E
A D
IN
E
S S
C E
N T
E R
N O
R T
H C
A R
O L
IN
A
A R
M Y
N A
T
IO
N A
L G
U A
R D
03 APRIL 2017
DATEREV DESCRIPTION
501 North Broadway, Saint Louis, Missouri 63102
DISCLAIMER
ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE
ONLY FOR THE PURPOSE OF AUTHENTICATING THIS
DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS
RELATING TO THIS PROJECT IS DISCLAIMED
NC Engineering Firm License No. F-0287 NC Architectural Firm No. 50757
B
IM
/U
S
N o rt h C a ro lin a A rm y N a ti o n a l G u a rd
F W
/N
C A
R N
G R e a d in e s s C e n te r_ A
R C
H V
.r v t
/1
/2
:0 :5
P
M
A-713DEF
JAD
AJT
ARCHITECTURAL
SIGNAGE TYPES
AND DETAILS
NOT TO SCALEA1
SIGN TYPE EV
0 6" 1'
3" = 1'-0"
3"
0 2'
1 1/2" = 1'-0"
6" 1'
A-411
1 1/2" = 1'-0"A2
SIGN TYPE SFA
A-711
3" = 1'-0"A3
SIGN TYPE TE
A-711
NOT TO SCALEA4
SIGN TYPE TR
A-711
NOT TO SCALEB1
SIGN TYPE IN-3
A-711
3" = 1'-0"B2
SIGN TYPE IN-4
A-711
3" = 1'-0"B3
FIRE EXTINGUISHER / AED SIGN
A-533
3" = 1'-0"B4
SIGN TYPE RI
A-711
1 1/2" = 1'-0"C1
SIGN TYPE IN
A-711
IN-1 MECHANICAL ROOM
IN-2 ELECTRICAL ROOM / INVERTER
IN-3 REFER TO B1 / A-713
IN-4 REFER TO B2 / A-713
IN-5 UNIT LOCKERS
IN-6 FIRE PUMP
IN-7 REFER TO C3 / A-713
IN-8 UNIT STORAGE
IN-9 ASSEMBLY HALL
IN-10 FOOD SERVICE
IN-11 UNHEATED STORAGE
IN-12 MAIL DELIVERY
IN-13 GENERAL PURPOSE TRAINING BAYS
'IN' TYPE SIGNAGE KEY
SIGN ROOM NAME
1 1/2" = 1'-0"C3
SIGN TYPE IN-7
A-711
3/8" = 1'-0"D1
BUILDING SIGNAGE
1 1/2" = 1'-0"D2
BUILDING SIGNAGE DETAIL
A-711 A-713
3/8" = 1'-0"
8'2' 4'1'
1" = 1'-0"C4
SIGN TYPE BN - BUILDING NUMBER SIGN
A-712
0 2'
1" = 1'-0"
6" 1' 3' dimartj Snapshot dimartj Rectangle dimartj Snapshot dimartj Cloud dimartj Snapshot dimartj Rectangle dimartj Cloud dimartj Snapshot dimartj Line dimartj Snapshot dimartj Line dimartj Rectangle
A
1/2" TEE
1/2" DIA X 2'-0" LONG
CONDENSATE AND DIRT LEG
1/2" COMPRESSED
AIR DROP
1/2" SHUT-OFF VALVE
1/2" FPT COMBINATION
PRESSURE REGULATING
VALVE/IN-LINE FILTER WITH
INTEGRAL PRESSURE
GAUGE; OPERATING RANGE 5
PSI TO 125 PSI; INTEGRAL 25
MICRON FILTER
REDUCING TEE
FINISHED FLOOR
COMPRESSED AIR
MAIN, SEE PLANS
FOR SIZES
AIR OUTLET, FEMALE
QUICK COUPLER TYPE
WITH BUILT-IN AUTOMATIC
CHECK UNIT. SIZE/STYLE
PER CONTRACTING
OFFICER
SUPPORT VERTICAL
RISER AGAINST WALL
PER SPECIFICATIONS
PIPE CAP
1/2" BLOW-OFF VALVE
4' -0
' A
FF
EYE-WASH
PLUGGED NIPPLE
PUSH LEVER
EXTENSION SPLIT
CLAMP PIPE HANGER
SECURED TO WALL
1" CHAIN OPERATED
BALL VALVE
PULL
HANDLE
SHOWER
HEAD
NOTE: ALARM AND STROBE LIGHT
NOT SHOWN.
85°
SUPPLY (ALTERNATE)
EXTERIOR WALL
STANDARD 1-1/4"
PIPE FLANGE
1 1/4" WASTE AT
2'-0" AFF TO SPILL
ON-GRADE
EXPANSION BOLTS,
4 REQUIRED
FINISHED
FLOOR/ GRADE
DWH-2
1 1/4"
1 1/4" TEPID WATER
OUTSIDE INSIDE
ESE-2
PROVIDED WITH
AUTOMATIC THERMAL
ACTUATOR FREEZE
PROTECTION BLEED
VALVE
24"
4" PIPE
AND FITTINGS
STANDARD-
TEE OR ELBOW
PER LOCAL CODE
3", 6" AND 12" GR2432
GRADE RINGS AS
REQUIRED
24" CAST IRON FRAMES AND COVERS WITH
GASKET (GAS TIGHT) 2 TOTAL
RATED FOR HEAVY TRAFFIC
REFER TO CIVIL
SITE PLAN FOR
LOCATION
320 GALLON CAPACITY
3' -7
3' -4
” 4' -6
INLET
OUTLET
BOTTOM OUTLET
CONNECTION ELEVATION
SHALL BE A MAXIMUM OF 18
INCHES BELOW FINISHED
FLOOR.
CATCH BASIN (SAND INTERCEPTOR)
WITH BOTTOM OUTLET.
SECTIONAL TRENCH WITH SECURED EXTRA HEAVY
DUTY SLOTTED DUCTILE IRON GRATES APPROXIMATELY
24' LONG IN WORK BAYS. MAXIMUM DEPTH SHALL BE 18
INCHES. UNIT SHALL BE SUITABLE FOR TRACKED
VEHICLE TRAFFIC.
RECEIVER
120 GAL
AC-1
2" CA TO MAINTENANCE
WORKBAYS REF PLANS
FOR CONTINUATION
FINISHED
FLOOR
DRAIN
VALVE
AIR COOLED
AFTER COOLERSAIR INLET FILTER
D
C
B
A
1 2 3 4 5
BID FINAL SUBMITTAL
Designed:
Drawn :
Checked:
Drawing No.:
Date:
Drawing Title:
Scales:
P R
O J E
C T
N O
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
N A
T
IO
N A
L G
U A
R D
R E
A D
IN
E
S S
C E
N T
E R
N O
R T
H C
A R
O L
IN
A
A R
M Y
N A
T
IO
N A
L G
U A
R D
03 APRIL 2017
DATEREV DESCRIPTION
501 North Broadway, Saint Louis, Missouri 63102
DISCLAIMER
ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE
ONLY FOR THE PURPOSE OF AUTHENTICATING THIS
DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS
RELATING TO THIS PROJECT IS DISCLAIMED
NC Engineering Firm License No. F-0287 NC Architectural Firm No. 50757
B
IM
/U
S
N o rt h C a ro lin a A rm y N a ti o n a l G u a rd
F
W
/N
C A
R N
G
R e a d in e s s C e n te r_
P L
U M
B V
.r v t
/1
/2
:5
:2
A
M
P-502JOT
APB
APB
PLUMBING
DETAILS
ABI No. 1 & 2
NOT TO SCALEC3
COMPRESSED AIR OUTLET DETAIL - ABI No. 2
NOT TO SCALEA1
EMERGENCY SHOWER & EYEWASH DETAIL - ABI No. 1
NOT TO SCALEC2
OIL/WATER SEPARATOR DETAIL - ABI No. 2
NOT TO SCALEC1
TD-1 TRENCH DRAIN DETAIL - ABI No. 2
P-502 P-502 P-502
P-502
NOT TO SCALEA2
DUPLEX AIR COMPRESSOR DETAIL
P-502
1 Revision 1 08/16/16
C
A
B
3/4"ø HWR 1 1/4"ø HW
1 1/2"ø CW
3/4"ø CW
3/ 4" ø C
W
1"ø CW
1/ 2" ø C
W
1/ 2" ø H
W 3" ø S
S 1 1/
4" ø
C W
1/
4" ø
H W
3/ 4" ø C
W
4"ø SS
3/4"ø HWR 1 1/4"ø HW
1 1/2"ø CW
WH-1WH-1
ESE-1
AC
GENERAL PURPOSE TRAINING BAYS
VESTIBULE
ASSEMBLY HALL
2"ø CA 2"ø CA
1/ 2" ø C
A
1/ 2" ø C
A
HB-1 HB-1
SK-3
1/ 2" ø C
A
1/ 2" ø C
A 2"ø CA
2" ø
C A
2" ø
C A
TD-1 TD-1
4"ø SS
3"ø SS
6"ø SS
4"ø SS
6"ø SS
4" ø
S S
FCO
REFER TO CIVIL
DRAWING CS400 FOR
CONTINUATION
4"SS
I.E. 95.33
3"SS
I.E. 95.33
REFER TO A1/P-801
FOR CONTINUATION
N
D
C
B
A
1 2 3 4 5
BID FINAL SUBMITTAL
Designed:
Drawn :
Checked:
Drawing No.:
Date:
Drawing Title:
Scales:
P R
O J E
C T
N O
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
N A
T
IO
N A
L G
U A
R D
R E
A D
IN
E
S S
C E
N T
E R
N O
R T
H C
A R
O L
IN
A
A R
M Y
N A
T
IO
N A
L G
U A
R D
03 APRIL 2017
DATEREV DESCRIPTION
501 North Broadway, Saint Louis, Missouri 63102
DISCLAIMER
ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE
ONLY FOR THE PURPOSE OF AUTHENTICATING THIS
DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS
RELATING TO THIS PROJECT IS DISCLAIMED
NC Engineering Firm License No. F-0287 NC Architectural Firm No. 50757
B
IM
/U
S
N o rt h C a ro lin a A rm y N a ti o n a l G u a rd
F
W
/N
C A
R N
G
R e a d in e s s C e n te r_
P L
U M
B V
.r v t
/1
/2
:5
:2
A
M
P-802JOT
APB
APB
PLUMBING
ENLARGED PLAN
ABI No. 2
PLUMBING PLAN GENERAL NOTES
1. REFER TO P-001 FOR SYMBOLS AND ABBREVIATIONS.
1/4" = 1'-0"
P-801
A1 ENLARGED PLUMBING PLAN - ABI No. 2
1/4" = 1'-0"
2' 4' 8' 12'
9 6" SANITARY SEWER FROM GREASE TRAP BY SITE CONTRACTOR(SHOWN FOR CLARITY
ONLY). REFER TO DRAWING CS400 FOR EXACT LOCATION AND INVERT ELEVATION.
KEYED NOTES
1 Revision 1 08/16/16
EWC-1
MB-1
SH-1
WC-1
SH-1
SH-2
SK-1
WC-1
WC-1
WC-1
WC-2
L-1
L-1
L-1
L-1
L-1
L-1L-1
L-1
U-2
SH-1
SH-1
SH-1
SH-1
SH-2
WC-2
WC-1
WC-1
1/2"CW AND 1/2"HW
UP TO MB-1
3/4"CW TO WH-1
PIPING UP TO ASSEMBLY
HALL CEILING SPACE.
FOR CONTINUATION
REFER TO A1/P-105.
FOR CONTINUATION
REFER TO A1/P-801
2"CW UP AND
3/4"HW UP TO
SECOND FLOOR
3/4"CW TO WH-1
1"ø HW
1/2"ø HW
2"ø CW
1"ø CW
1/2"ø HW 1/2"ø CW
1/2"ø CW
2"ø CW
1/2"ø CW
3/4"ø HW
2"ø CW
3/4"ø CW
1/2"ø HW
2 1/2"ø CW 1 1/4"ø HW 1"ø HW (140°F) 1"ø HWR 3/4"ø HWR (140°F)
3/4"ø HWR (140°F) 1"ø HWR 1"ø HW (140°F) 1 1/4"ø HW
2 1/2"ø CW
1"ø HW
3/4"ø CW
1"ø HW
1/2"ø HW
1"ø HW
1/2"ø CW
1/2"ø CW
1/2"ø HW
TP-1
TP-1
FOR CONTINUATION
REFER TO A1/P-105.
FOR CONTINUATION REFER TO A3/P-103
WH-1
3/4"ø HWR (140°F)
1"ø HWR
1"ø HW (140°F)
1 1/4"ø HW
2"ø CW
1/2"ø HW1/2"ø HW
1/2"ø CW1/2"ø CW
1/2"ø HW (140°F)
3/4"ø CW
1/2"ø HW
1/2"ø CW
1/2"ø HW 1/2"ø CW
3/4"ø CW
1 1/4"ø CW
3/4"ø HWR
1 1/2"ø CW
1"ø HW
1"ø HW (140°F)
3/4"ø HWR
3/4"ø HWR (140°F)
1/2"ø CW
1/2"ø HW
3/4"ø CW
3/4"ø CW 3/4"ø HW 3/4"ø HW (140°F)
1/2"ø CW
1/2"ø HW
WH-1
L-1
1/2"CW BELOW GRADE TO
COLD FOOD COUNTER
4"CW
FOR CONTINUATION REFER
TO CIIVL DRAWINGS
4"ø CW 3/4"ø CW
WH-1
TP
ET
ST
DWH
MV-1
CP
CP
HB-1
3/4"ø CW
2 1/2"ø CW 2"ø HW
1"ø HW (140°F)
1"ø HWR
3/4"ø HWR (140°F)
4"ø CW
4"ø CW
3/4"ø CW
3/4"ø HWR
2"ø HW (140°F)
3/4"ø HWR
CP
FOR CONTINUATION
REFER TO A1/P-102
MB-1
EWC-1
L-1
L-1
L-1
L-1 U-2
U-1
WC-1
WC-1WC-1WC-2
WC-2
WC-1
WB-1
WB-1
SK-2
WB-1 1/2"CW FROM
FIRST FLOOR
1/2"CW AND
1/2"HW FROM
FIRST FLOOR
1/2"CW AND
1/2"HW FROM
FIRST FLOOR
1/2"CW DOWN
TO FIRST FLOOR
3/4"HW DOWN
TO FIRST FLOOR
3/4"HW FROM
FIRST FLOOR
2"CW FROM
FIRST FLOOR
D
C
B
A
1 2 3 4 5
BID FINAL SUBMITTAL
Designed:
Drawn :
Checked:
Drawing No.:
Date:
Drawing Title:
Scales:
P R
O J E
C T
N O
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
N A
T
IO
N A
L G
U A
R D
R E
A D
IN
E
S S
C E
N T
E R
N O
R T
H C
A R
O L
IN
A
A R
M Y
N A
T
IO
N A
L G
U A
R D
03 APRIL 2017
DATEREV DESCRIPTION
501 North Broadway, Saint Louis, Missouri 63102
DISCLAIMER
ATTACHMENT OF THIS SEAL TO THIS DOCUMENT IS MADE
ONLY FOR THE PURPOSE OF AUTHENTICATING THIS
DOCUMENT. RESPONSIBILITY FOR ALL OTHER DOCUMENTS
RELATING TO THIS PROJECT IS DISCLAIMED
NC Engineering Firm License No. F-0287 NC Architectural Firm No. 50757
B
IM
/U
S
N o rt h C a ro lin a A rm y N a ti o n a l G u a rd
F
W
/N
C A
R N
G
R e a d in e s s C e n te r_
P L
U M
B V
.r v t
/1
/2
:5
:2
A
M
P-902JOT
APB
APB
PLUMBING
WATER
RISERS
A1
FIRST FLOOR TOILET ROOM DOMESTIC WATER ISOMETRIC
B1
KITCHEN DOMESTIC WATER ISOMETRIC
B2
MECHANICAL ROOM DOMESTIC WATER ISOMETRIC
PLUMBING PLAN GENERAL NOTES
1. REFER TO P-001 FOR SYMBOLS AND ABBREVIATIONS.
7 PROVIDE DRAIN DOWN FOR TRAPPED PIPING AT THIS LOCATION. REFER TO DETAIL
A4/P-501.
18 HOT WATER BOOSTER HEATER. ROUTE 180°F HW PIPE (NOT SHOWN) TO SANITIZER
FAUCET OF TRIPLE BOWL SINK.
19 HAND SINK
20 DUAL BOWL VEGETABLE SINK
21 ICE MAKER
22 TRIPLE BOWL SINK
25 CAN WASH
KEYED NOTES
A3
SECOND FLOOR TOILET ROOM DOMESTIC WATER ISOMETRIC
1 Revision 1 08/16/16