National Guard Readiness Center Wilmington, North Carolina Addendum 1 16 August 2017
DOOR HARDWARE 087100 - 1
SECTION 087100 - DOOR HARDWARE
PART 1 – GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section includes furnishing and installation of door hardware for doors specified in “Hardware Sets” and required by actual conditions. Including screws, bolts, expansion shields, electrified door hardware, and other devices for proper application of hardware.
B. Where items of hardware are not specified and are required for intended service, such omission, error or other discrepancy shall be submitted to Architect fourteen calendar days prior to bid date for clarification by addendum.
C. Products supplied but not installed under this Section:
1. Final replacement of cylinder cores to be as directed by Owner.
2. Hold open wall magnets.
3. Electrified hardware will be furnished under this Section, but installed by the security contractor.
D. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
E. Related Divisions:
1. Division 08 Openings
2. Division 26 Electrical
3. Division 28 Access Control
4. Division 28 Fire Detection and Alarm
1.3 REFERENCES
A. American National Standards Institute/Builders Hardware Manufacturers Association
(ANSI):
1. ANSI/BHMA A156.1 Butts & Hinges (2006)
2. ANSI/BHMA A156.2 Bored & Preassembled Locks & Latches (2011)
3. ANSI/BHMA A156.3 Exit Devices (2008)
4. ANSI/BHMA A156.4 Door Controls – Closers (2008)
5. ANSI/BHMA A156.6 Architectural Door Trim (2010)
DOOR HARDWARE 087100 - 2
6. ANSI/BHMA A156.7 Template Hinge Dimensions (2009)
7. ANSI/BHMA A156.8 Door Controls – Overhead Stops and Holders (2010)
8. ANSI/BHMA A156.16 Auxiliary Hardware (2008)
9. ANSI/BHMA A156.18 Materials & Finishes (2006)
10. ANSI/BHMA A156.21 Thresholds (2009)
11. ANSI/BHMA A156.22 Door Gasketing Systems (2012)
12. ANSI/BHMA A156.25 Electrified Locks (2007)
13. ANSI/BHMA A156.28 Keying Systems (2007)
B. International Code Council/American National Standards Institute (ICC/ANSI)/ADA:
1. ICC/ANSI A117.1 Standards for Accessible and Usable Buildings and Facilities
(2003)
2. Americans with Disabilities Act Accessibility Guidelines (ADAAG).
C. Underwriters Laboratories, Inc. (UL):
1. UL 10C Positive Pressure Fire Test of Door Assemblies
2. UL 1784 Air Leakage Test of Door Assemblies
3. UL/ULC Listed
D. Door and Hardware Institute (DHI):
1. DHI Publication – Keying Systems and Nomenclature (1989)
2. DHI Publication – Abbreviations and Symbols
3. DHI Publication – Installation Guide for Doors and Hardware
4. DHI Publication – Sequence and Format of Hardware Schedule (1996)
E. National Fire Protection Agency (NFPA)
1. NFPA 70 National Electrical Code (2008)
2. NFPA 80 Standard for Fire Doors and Other Opening Protective’s (2007)
3. NFPA 101 Life Safety Code (2006)
4. NFPA 105 Standard for the Installation of Smoke Door Assemblies (2007)
F. Building Codes
1. IBC International Building Code (2009)
2. North Carolina Building Code.
1.4 SUBMITTALS
A. Submit in accordance with Conditions of the Contract and Division 1 Administrative Requirements.
B. Shop Drawings:
1. Hardware schedule shall be organized in vertical format illustrated in DHI Publications Sequence and Formatting for the Hardware Schedule. Include
DOOR HARDWARE 087100 - 3
abbreviations and symbols page according to DHI Publications Abbreviations and Symbols. Complete nomenclature of items required for each door opening as indicated.
2. Coordinate the final Door Hardware Schedule with doors, frames, and related work to ensure proper size, thickness, hand, function, and finish of hardware.
3. Architectural Hardware Consultant (AHC), as certified by DHI, who shall affix seal attesting to completeness and correctness, shall review hardware schedule prior to submittal.
C. Submit manufacturer’s catalog sheet on design, grade and function of items listed in hardware schedule. Identify specific hardware item per sheet, provide index, and cover sheet.
D. Coordination: Distribute door hardware templates to related divisions within fourteen days of receiving approved door hardware submittals.
E. Electrified Hardware: Provide electrical information to include voltage, and amperage requirements for electrified door hardware and description of operation.
1. Description of operation for each electrified opening to include description of component functions including location, sequence of operation and interface with other building control systems.
2. Wiring Diagrams: Detail wiring for power, signal, and control system and differentiate between manufacturers installed and field installed wiring. Include the following:
a. System schematic
b. Point to point wiring diagram
c. Riser diagram
d. Elevation of each door
3. Detail interface between electrified door hardware and fire alarm, access control, security, and building control systems.
F. Upon door hardware submittal approval, provide for each electrified opening, three copies of point to point diagrams.
G. Closeout Submittals: Submit to Owner in a three ringed binder or CD if requested.
1. Warranties.
2. Maintenance and operating manual.
3. Maintenance service agreement.
4. Record documents.
5. Copy of approved hardware schedule.
6. Copy of approved keying schedule with bitting list.
7. Door hardware supplier name, phone number and fax number.
DOOR HARDWARE 087100 - 4
1.5 QUALITY ASSURANCE
A. Electrified door hardware shall be Listed and Labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authority having jurisdiction.
B. Hardware supplier shall employ an Architectural Hardware Consultant (AHC) as certified by DHI and a member of the seal program who shall be available at reasonable times during course of work for Project hardware consultation.
1. Electrified Door Hardware Supplier Qualifications: Experienced door hardware supplier who has completed projects with electrified door hardware similar in material, design, and extent to that indicated for this Project, whose work has resulted in construction with a record of successful in service performance.
C. Door hardware shall conform to ICC/ANSI A117.1. : Handles, Pulls, Latches, Locks and operating devices: Shape that is easy to grasp with one hand and does not require tight grasping, tight pinching, or twisting of the wrist.
D. Fire Rated Door Assemblies: Where fire-rated door assemblies are indicated, provide door hardware rated for use in assemblies complying with NFPA 80 that are listed and labeled by a qualified testing agency, for fire-protection ratings indicated, based on testing at positive pressure according to UL 10C, unless otherwise indicated.
E. Fire Door Inspection: Prior to receiving certificate of occupancy have fire rated doors inspected by an independent certified Fire and Egress Door Assembly Inspector (FDAI), as certified by Intertek (ITS), a written report shall be submitted to Owner and Contractor. Doors failing inspection shall be adjusted, replaced or modified to be within appropriate code requirements.
F. Smoke and Draft Control Door Assemblies: Where smoke and draft control door assemblies are required, provide door hardware that meets requirements of assemblies tested according to UL 1784 and installed in compliance with NFPA 105.
G. Door hardware shall be certified to ANSI/BHMA standards as noted, participate and be listed in BHMA Certified Products Directory.
H. Substitution request: Shall include the reason for requesting the substitution, clear catalog copy highlighting the proposed product and options, compliance statement, technical data, product Warranty and lead time, to show how the proposed can meet or exceed established level of design function and quality. Approval of request is at the discretion of the owner, architect and their designated consultants.
I. Pre-installation Meeting: Comply with requirements in Division 1 Section “Project Meetings.”
1. Convene meeting seven days before installation. Participants required to attend:
Contractor, installer, material supplier, manufacturer representatives, electrical contractor, security consultant and fire alarm consultant.
2. Include in conference decisions regarding proper installation methods and procedures for receiving and handling hardware.
DOOR HARDWARE 087100 - 5
3. Review sequence of operation for each type of electrified door hardware, inspect, and discuss electrical roughing-in and other preparatory work performed by other trades.
4. Review and finalize construction schedule and verify availability of materials, installer’s personnel, equipment and facilities needed to make progress and avoid delays.
J. Within fourteen days of receipt of approved door hardware submittals contact Owner with representative from hardware supplier to establish a keying conference. Verify keyway, visual key identification, number of master keys and keys per lock. Provide keying system per Owners instructions.
K. Installer Qualifications: Specialized in performing installation of this Section and shall have five years minimum documented experience.
L. Hardware listed in Hardware Schedule is intended to establish a type and grade.
1.6 DELIVERY, STORAGE AND HANDLING
A. Provide a clean, dry and secure room for hardware delivered to Project but not yet installed.
B. Furnish hardware with each unit marked and numbered in accordance with approved finish hardware schedule. Include door and item number for each type of hardware.
C. Pack each item complete with necessary parts and fasteners in manufacturer’s original packaging.
D. Deliver permanent keys, cores and related accessories directly to Owner via registered mail or overnight package service. Instructions for delivery to Owner shall be established at “Keying Conference.”
E. Waste Management and Disposal: Separate waste materials for reuse or recycling in accordance with Division 1.
1.7 WARRANTY
A. General Warranty: Owner may have under provisions of the Contract Documents and shall be an addition and run concurrent with other warranties made by Contractor under requirements of the Contract documents.
B. Special Warranty: Warranties specified in this article shall not deprive Owner of other rights. Contractor, hardware supplier, and hardware installer shall be responsible for servicing hardware and keying related problems.
1. Ten years for manual door closers.
2. Five years for mortise, auxiliary and bored locks.
3. Five years for exit devices.
DOOR HARDWARE 087100 - 6
4. One year for electromechanical door hardware.
C. Products judged defective during warranty period shall be replaced or repaired in accordance with manufacturer’s warranty at no cost to Owner. There is no warranty against defects due to improper installation, abuse and failure to exercise normal maintenance.
D. Maintenance Tool and Instructions: Furnish a complete set of specialized tools and maintenance instructions for Owner’s continued adjustment, maintenance, removal and replacement of door hardware.
PART 2 – PRODUCTS
2.1 HINGES
A. Hinges, electric hinges shall be of one manufacturer as listed for continuity of design and consideration of warranty.
B. Standards: Products to be certified and listed by the following:
1. Butts and Hinges: ANSI/BHMA A156.1
2. Template Hinge Dimensions: ANSI/BHMA A156.7
C. Butt Hinges:
1. Hinge weight and size unless otherwise indicated in hardware sets:
a. Doors up to 36” wide and up to 1-3/4” thick provide hinges with a minimum thickness of .134” and a minimum of 4-1/2” in height.
b. Doors from 36” wide up to 42” wide and up to 1-3/4” thick provide hinges with a minimum thickness of .145” and a minimum of 4-1/2”” in height.
c. For doors from 42” wide up to 48” wide and up to 1-3/4” thick provide hinges with a minimum thickness of .180” and a minimum of 5” in height.
d. Doors greater than 1-3/4” thick provide hinges with a minimum thickness of .180” and a minimum of 5” in height.
e. Width of hinge is to be minimum required to clear surrounding trim.
2. Base material unless otherwise indicated in hardware sets:
a. Exterior Doors: 304 Stainless Steel, Brass or Bronze material.
b. Interior Doors: Steel material.
c. Fire Rated Doors: Steel or 304 Stainless Steel materials.
d. Stainless Steel ball bearing hinges shall have stainless steel ball bearings. Steel ball bearings are unacceptable.
3. Quantity of hinges per door unless otherwise stated in hardware sets:
a. Doors up to 60”in height provide 2 hinges.
b. Doors 60” up to 90” in height provide 3 hinges.
c. Doors 90” up to 120” in height provide 4 hinges.
DOOR HARDWARE 087100 - 7
d. Doors over 120” in height add 1 additional hinge per each additional 30” in height.
e. Dutch doors provide 4 hinges.
4. Hinge design and options unless otherwise indicated in hardware sets:
a. Hinges are to be of a square corner five-knuckle design, flat button tips and have ball bearings unless otherwise indicated in hardware sets.
b. Out-swinging exterior and out-swinging access controlled doors shall have non-removable pins (NRP) to prevent removal of pin while door is in closed position.
c. When full width of opening is required, use hinges that are designed to swing door completely from opening when door is opened to 95 degrees.
d. Electric Through Wire (ETW) to have appropriate number of wires to transfer power through door frame to door for proper connection of finish hardware and certified to handle an amperage rating of 3.5AMPS/continuous duty with 16.0AMPS/intermittent duty.
e. Provide mortar boxes for frames that require any electrically modified hinges if not an integral part of frame.
f. When shims are necessary to correct frame or door irregularities, provide metal shims only.
5. Acceptable Manufacturers:
Standard Weight Heavy Weight
a. Hager Companies BB1279/BB1191 BB1168/BB1199
b. Bommer BB5000/BB5002 BB5004/BB5006
c. McKinney TA2714/TA2314 T4A3786/T4A3386
2.2 FLUSH BOLTS AND COORDINATORS
A. Flushbolts shall be of one manufacturer as listed for continuity of design and
B. Standards: Manufacturer to be listed by the following: Auxiliary Hardware: ANSI/BHMA A156.16
C. Labeled openings: Provide automatic or constant latching flush bolts per hardware schedule for inactive leaf of pairs of doors. Provide dust proof strikes for bottom bolt.
D. Non-Labeled openings: Provide two flush bolts for inactive leaf of pairs of doors per hardware schedule. Top bolt shall not be more than 78” centerline from floor. Provide dust proof strike for bottom bolt.
E. Acceptable Manufacturers:
Auto Flush Bolt Dust Proof Strike
1. Hager Companies 291D/292D 280X
2. Rockwood 1942 570
DOOR HARDWARE 087100 - 8
3. Trimco 3815 3911
F. Coordinators: Provide for labeled pairs of doors with automatic flush bolts or with vertical rod exit device with a mortise-locking device per hardware schedule. Provide filler piece to extend full width of stop on frame. Provide mounting brackets for closers and special preparation for latches where applicable.
1. Mounting of aluminum extrusion weather-strip to 297M/N full width of opening minus two times frame stop height.
G. Acceptable Manufacturers:
Coordinator Bracket Bracket for stops greater than 2-1/4”
1. Hager Companies 297D 297M 297N
2. Rockwood 1600 1601AB 1601C
3. Trimco 3094 3095 3096
2.3 LOCKS AND LATCHES
A. Locks and latches shall be of one manufacturer as listed for continuity of design and
B. Standards: Product to be certified and listed by following:
1. ANSI/BHMA A156.13 Series 1000 Certified to Grade 1 for Operational and Security.
2. UL/cUL Labeled and listed up to 3 hours for single doors up to 48” in width and up to
96” in height.
3. UL10C/UBC 7-2 Positive Pressure Rated.
4. ICC/ANSI A117.1.
C. Lock and latch function numbers and descriptions of manufactures series as listed in hardware sets.
D. Material and Design:
1. Lock cases from fully wrapped, 12 gauge steel, Zinc dichromate for corrosion resistance.
2. Non-handed, field reversible without opening lock case.
3. Break away spindles to prevent unlocking during forced entry or vandalism.
4. Levers are to be Zinc cast, Forged Brass or Stainless Steel and plated to match finish designation in hardware sets.
5. Sectional Roses are to be of solid Brass or Stainless Steel material and have a minimum diameter of 2-7/16”.
6. Armor fronts are to be self-adjusting to accommodate a square edge door or a standard 1/8” beveled edge door.
E. Latch and Strike:
1. Stainless Steel latch bolt with minimum of ¾” throw and deadlocking for keyed and exterior functions.
2. Strike is to fit a standard ANSI A115 prep measuring 1-1/4” x 4-7/8” with proper lip length to protect surrounding trim.
DOOR HARDWARE 087100 - 9
3. Deadbolts to be 1-3/4” total length with a minimum of a 1” throw and ¾” internal engagement when fully extended and made of Stainless Steel material.
F. Acceptable Manufacturers:
1. Hager Companies: 3800 Series.
2. Best: 45 series
3. Sargent: 8200 Series
2.4 EXIT DEVICES
A. Shall be touch pad type, finish to match balance of door hardware. Exit Devices shall be of one manufacturer as listed for continuity of design and consideration of warranty.
B. Standards: Manufacturer to be certified and or listed by the following:
1. BHMA Certified ANSI A156.3 Grade 1
2. UL/cUL Listed for up to 3 hours for “A” labeled doors
3. UL10C/UBC 7-2 Positive Pressure Rated
4. UL10B Neutral Pressure Rated
5. UL 305Listed for Panic Hardware
6. 2007 Florida Building Code Certification Number: FL9481.1
7. ANSI/BHMA A250.13 Severe Windstorm Resistant Component
C. Material and Design:
1. Touch pad shall extend a minimum of one half-door width. Freewheeling lever design shall match design of locks levers. Exit device to mount flush with door.
2. Latchbolts:
a. Rim device – ¾” throw, Pullman type with automatic dead-latching, stainless steel
b. Surface vertical rod device – Top ½” throw, Pullman type with automatic dead-latching, stainless steel. Bottom ½” throw, Pullman type, held retracted during door swing, stainless steel.
3. Fasteners: Wood screws, machine screws and thru-bolts.
D. Lock and Latch Functions: Function numbers and descriptions of manufacturer’s series and lever styles indicated in door hardware sets.
E. Electric Modifications:
1. Motor Latch Retraction: Continuous duty solenoids retract the latch bolt for momentary or maintained periods of time.
1. Hager Companies: 4500 Series
2. Von Duprin: 98 Series
DOOR HARDWARE 087100 - 10
2.5 CYLINDERS AND KEYING
A. Cylinders shall be of one manufacturer as listed for continuity of design and
B. Standards: Manufacturer shall meet the following:
1. Auxiliary Locks: ANSI/BHMA A156.5
2. DHI Handbook “Keying systems and nomenclature” (1989)
C. Cylinders:
1. Manufacturer’s standard tumbler type, seven-pin IC core to match existing.
2. Shall be furnished with cams/tailpieces as required for locking device that is being furnished for project.
D. Keying:
1. Copy of Owners approved keying schedule shall be submitted to Owner and Architect with documentation of which keying conference was held and Owners sign-off.
2. Provide a bitting list to Owner of combinations as established, and expand to twenty five percent for future use or as directed by Owner.
3. Key into Owner’s existing keying system.
4. Keys to be shipped to Owner’s representative, individually tag per keying conference.
5. Provide visual key control identification on keys.
6. Provide interchangeable cores with construction cores and 50 construction keys.
E. Acceptable manufacturers:
1. Best,
2. EXCEPT EXTERIOR OPENINGS – BY OTHERS
2.6 PUSH/PULL PLATES
A. Push and pull plates shall be of one manufacturer as listed for continuity of design and
B. Standards: Manufacturer to be certified by the following:
1. Architectural Door Trim: ANSI/BHMA A156.6
C. Push plates: .050” thick, square corner and beveled edges with counter sunk screw holes. Width and height as stated in hardware sets.
D. Acceptable Manufactures:
1. Hager Companies: 30S
2. Rockwood
DOOR HARDWARE 087100 - 11
3. Trimco
E. Pull plates: .050” thick, square corner and beveled edges. Width and height as stated in hardware sets, ¾” diameter pull, with clearance of 2-1/2” from face of door.
1. Hager Companies: H33J
G. Push Pull Bar Sets: 1” round bar stock with 2 ½” clearances from face of door.
H. Acceptable Manufacturers:
1. Hager Companies: 12L
2.7 CLOSERS
A. Shall be product of one manufacturer. Unless otherwise indicated on hardware schedule, comply with manufacturer’s recommendation for size of closer, depending on width of door, frequency of use, atmospheric pressure, ADAAG requirements, and fire rating.
B. Standards: Manufacturer to be certified and or listed by the following:
1. BHMA Certified ANSI A156.4 Grade 1
2. ADA Compliant ANSI A117.1
3. UL/cUL Listed up to 3 hours.
4. UL10C Positive Pressure Rated
5. UL10B Neutral Pressure Rated
1. Provide cast iron non-handed bodies with full plastic covers.
2. Closers shall have separate staked adjustable valve screws for latch speed, sweep speed, and backcheck.
3. Provide Tri-Pack arms and brackets for regular arm, top jamb, and parallel arm mounting.
4. One-piece seamless steel spring tube sealed in hydraulic fluid.
5. Double heat-treated steel tempered springs.
6. Precision-machined heat-treated steel piston.
7. Triple heat-treated steel spindle.
8. Full rack and pinion operation.
DOOR HARDWARE 087100 - 12
D. Mounting:
1. Out swing doors shall have surface parallel arm mount closers except where noted on hardware schedule.
2. In swing doors shall have surface regular arm mount closers except where noted on hardware schedule.
3. Provide brackets and shoe supports for aluminum doors and frames to mount fifth screw.
4. Furnish drop plates where top rail conditions on door do not allow for mounting of closer and where backside of closer is exposed through glass.
E. Size closers in compliance with requirements for accessibility (ADDAG). Comply with following maximum opening force requirements.
1. Interior hinged openings: 5.0 lbs.
2. Fire rated and exterior openings shall have minimum opening force allowable by authority having jurisdiction.
F. Fasteners: Provide self-reaming and self-tapping wood and machine screws and sex nuts and bolts for each closer.
G. Acceptable manufacturers:
1. Hager Companies: 5100 Series
2. LCN: 4040XP Series
2.8 PROTECTIVE TRIM
A. Size of protection plate: Single doors, size two inches less door width (LDW) on push side of door, and one inch less on pull side of door. For pairs of doors, size one inch less door width (LDW) on push side of door, and ½ inch on pull side of door.
1. Kickplates 10” high or sized to door bottom rail height
2. Mop Plates – 4” high
B. Standards: Manufacturer shall meet requirements for:
1. Architectural Door Trim: ANSI/BHMA A156.6
2. UL
1. 0.050” gage stainless steel
2. Corners shall be square. Polishing lines or dominant direction of surface pattern shall run across the door width of plate.
3. Bevel top, bottom and sides uniformly leaving no sharp edges. Edges shall be de-burred.
4. Countersink holes for screws. Screws holes shall be spaced equidistant eight inches
CTC, along a centerline not over ½ inch in from edge around plate. End screws shall be a maximum of 0.53 inch from corners.
DOOR HARDWARE 087100 - 13
D. UL label stamp required on protection plates when top of plate is more than 16 inches above bottom of door on fire rated openings. Verify door manufactures UL listing for maximum height and width of protection plate to be used.
E. Acceptable Manufacturers:
1. Hager Companies: 194S
2. Trimco: PG8002
3. Burns
2.9 STOPS AND HOLDERS
A. Wall Stops: Provide door stops wherever necessary to prevent door or hardware from striking an adjacent partition or obstruction. Provide wall stops when possible. Door stops and holders mounted in concrete floor or masonry walls shall have stainless steel machine screws and lead expansion shields.
B. Standards: Manufacturer shall meet requirements for:
1. Auxiliary Hardware: ANSI/BHMA A156.16
C. Acceptable Manufacturers:
Convex Concave
1. Hager Companies 232W 236W
3. Burns
D. Overhead Stops and Holders: Provide overhead stop and holders for doors that open against equipment, casework sidelights and other objects that would make wall stops/holders and floor stops/holders inappropriate. Provide sex bolt attachments for mineral core wood door applications.
E. Standards: Manufacturer shall be certified by the following:
1. Overhead Stops and Holders: ANSI/BHMA A156.8 Grade 1
Heavy Duty Surface
1. Hager Companies 7000 SRF Series
2. Glynn Johnson 90 Series
3. Sargent 590 Series
2.10 POWER TRANSFER
A. Shall be of one manufacturer as listed for continuity of design and consideration of warranty.
DOOR HARDWARE 087100 - 14
1. UL Listed
C. Design:
1. Use with modular access control systems
2. Field selectable filtered and regulated 12 VDC or 24 VDC constant voltage
3. 1 AMP/2AMP load capacity
4. Circuit breaker protected AC input voltage, secondary output PTC protected
5. Fire alarm input provides simultaneous release of Fail Safe locks and holders
6. Interface relay
7. LED status indicators provide information regarding AC input, DC output, and battery backup status
8. Separate inputs for activation switch on entry and egress and ingress side of opening.
9. 5 amp hour battery backup
10. Input 115 VAC (230 VAC optional)
11. Optional dual 12 VDC or 24 VDC output
D. Acceptable Manufacturers:
1. Von Duprin PS914
2.11 DOOR GASKETING AND WEATHERSTRIP
A. Provide continuous weatherstrip gasketing on exterior doors and provide smoke, light, or sound gasketing where indicated on hardware schedule. Provide non-corrosive fasteners for exterior applications.
1. Perimeter gasketing: Apply to head and jamb, forming seal between door and frame.
2. Meeting stile gasketing: Fasten to meeting stiles, forming seal when doors are in closed position.
3. Door bottoms: Apply to bottom of door, forming seal with threshold or floor when door is in closed position.
4. Sound Gasketing: Cutting or notching for stop mounted hardware not permitted.
5. Drip Guard: Apply to exterior face of frame header. Lip length to extend 4” beyond width of door.
1. Door Gasketing and Edge Seal Systems: ANSI/BHMA A156.22
2. Shall be BHMA certified for door sweeps, automatic door bottoms, and adhesive applied gasketing. (721)
C. Smoke-Labeled Gasketing: Comply with NFPA 105 listed, labeled, and acceptable to authorities having jurisdiction, for smoke control indicated.
1. Provide smoke labeled gasketing on 20 minute rated doors and on smoke rated doors.
D. Fire-Rated Gasketing: Comply with NFPA 80 listed, labeled, and acceptable to Authorities Having Jurisdiction, for fire ratings indicated.
DOOR HARDWARE 087100 - 15
E. Refer to Section 08 1416 Wood Doors for Category A or Category B. Comply with UBC 7-2 and UL10C positive pressure where frame applied intumescent seals are required.
Provide Hager # 722
1. Perimeter Gasketing:
Adhesive Applied
a. Hager Companies: 726
b. K. N. Crowder
c. Reese:
2. Door Bottom Sweeps:
a. Hager Companies: 750S
b. K. N. Crowder
c. Reese:
3. Astragal
a. Hager Companies: 835S
b. K. N. Crowder
c. Reese:
2.12 THRESHOLDS
A. Set thresholds for exterior and acoustical openings in full bed of sealant with lead expansion shields and stainless steel machine screws complying with requirements specified in Division 7 Section “Joint Sealants”. Notched in field to fit frame by hardware installer. Refer to Drawings for special details.
B. Standards: Manufacturer to be certified by the following:
1. Thresholds: ANSI/BHMA A156.21
1. Hager Companies: 417S/520S
2. K. N. Crowder
3. Reese
2.14 SILENCERS
A. Where smoke, light, or weather seal are not required, provide three silencers per single door frame, two per double door frame and four per Dutch door frame.
1. Auxiliary Hardware: ANSI/BHMA A156.16
DOOR HARDWARE 087100 - 16
Hollow Metal Frame
1. Hager Companies: 307D
2. Rockwood:
3. Trimco:
2.15 KEY CABINET
A. Provide key cabinet, surface mounted to wall.
B. Key control system:
1. Include two sets of key tags, hooks, labels, and envelopes.
2. Contain system in metal cabinet with baked enamel finish.
3. Capacity shall be able to hold actual quantities of keys, plus 25 percent.
4. Provide tools, instruction sheets and accessories required to complete installation.
1. Lund Equipment
2. Telkey Incorporated
3. MMF
2.16 FINISHES
A. Appearance of Finished Work: Variations in appearance of abutting or adjacent pieces are acceptable if within range of approved Samples. Noticeable variations in the same piece are not acceptable. Variations in appearance of other components are acceptable if they are within range of approved Samples.
B. Comply with base material and finish requirements indicated by ANSI/BHMA A156.18 designations in hardware schedule.
PART 3 – EXECUTION
3.1 EXAMINATION
A. Examine doors and frames, with Installer present, for compliance with requirements for installation tolerances, labeled fire-rated door assembly construction, wall and floor construction, and other conditions affecting performance.
B. Examine roughing-in for electrical power systems to verify actual locations of wiring connections before electrified door hardware installation.
C. Proceed with installation only after unsatisfactory conditions have been corrected.
DOOR HARDWARE 087100 - 17
3.2 INSTALLATION
A. Install hardware per manufacturer’s instructions and in compliance with:
1. NFPA 80.
2. NFPA 105.
3. ICC/ANSI A117.1.
4. ANSI/BHMA A156.115 Hardware Preparation in Steel Doors and Steel Frames
5. ANSI/BHMA A156.115W Hardware Preparation in Wood Doors with Wood or Steel
Frames
6. DHI Publication – Installation Guide for Doors and Hardware
7. UL10C/UBC7-2
8. Local building code.
9. Approved shop drawings.
10. Approved finish hardware schedule.
B. Do not install surface mounted items until finishes have been completed on substrates involved. Set unit level, plumb and true to line location. Adjust and reinforce attachment substrate as necessary for proper installation and operation.
3.3 FIELD QUALITY CONTROL
A. Material supplier to schedule final walk through to inspect hardware installation ten business days before final acceptance of Owner. Material supplier shall provide a written report detailing discrepancies of each opening to General Contractor within seven calendar days of walk through.
3.4 ADJUSTMENT, CLEANING AND DEMONSTRATING
A. Adjustment: Adjust and check each opening to ensure proper operation of each item of finish hardware. Replace items that cannot be adjusted to operate freely and smoothly or as intended for application at no cost to Owner.
B. Cleaning: Clean adjacent surfaces soiled by hardware installation. Clean finished hardware per manufacturer’s instructions after final adjustments has been made.
Replace items that cannot be cleaned to manufacturer’s level of finish quality at no cost to Owner.
C. Demonstration: Conduct a training class for building maintenance personnel demonstrating the adjustment, operation of mechanical and electrical hardware. Special tools for finished hardware to be turned over and explained usage at this meeting.
3.5 PROTECTION
A. Leave manufacturer’s protective film intact and provide proper protection for all other finish hardware items that do not have protective material from the manufacture until Owner accepts Project as complete.
3.6 HARDWARE SET SCHEDULE
DOOR HARDWARE 087100 - 18
A. Guide: Door hardware items have been placed in sets which are intended to be a guide of design, grade, quality, function, operation, performance, exposure, and like characteristics of door hardware, and may not be complete. Provide door hardware required to make each set complete and operational.
B. Hardware schedule does not reflect handing, backset, method of fastening and like characteristics of door hardware and door operation.
C. Review door hardware sets with door types, frames, sizes and details on drawings.
Verify suitability and adaptability of items specified in relation to details and surrounding conditions.
3.7 HARDWARE SET SCHEDULE
Hardware Sets
SET #1
Doors: 101A, 130, 132A, 132B, 133A, 133B, 133D, 133E, 134, 140A, 141A, 142, 143A, 144, 147A, 156A, 157A, 158A, 158B
NOTE: CYLINDER(S) AS REQUIRED x CORE AS REQUIRED - REMAINDER OF HARDWARE BY
BLAST RESISTANT DOOR SUPPLIER. COORDINATE WITH SECURITY CONTRACTOR FOR
ACCESS CONTROL (158A)
1 Exit Device 4501 RIM 48” US26D HA
1 Exit Device Trim 45NL ARC US26D HA
1 Rim Cylinder Housing 3901 SFIC US26D HA
1 Cylinder Core 3982-C US26D HA
1 Closer 5100 5955-HDCS ALM HA
1 Drip Cap 810S x LAR MIL HA
1 Set Weatherstrip 881S N x LAR MIL HA
1 Door Bottom 770S V x LAR MIL HA
1 Threshold 520S V 48” MIL HA
NOTE: Hinges by Door Supplier
SET #2
Doors: 101B, 154
3 Hinge BB1279 4 1/2 X 4 1/2 US26D HA
1 Exit Device 4501 RIM 36" US26D HA
1 Exit Device Trim 45NL ARC US26D HA
1 Rim Cylinder Housing 3901 IC US26D HA
1 Cylinder Core 3982-C US26D HA
1 Closer 5100 5955-HDCS ALM HA
1 Set Weatherstrip 726 17' S HA
SET #3
DOOR HARDWARE 087100 - 19
Doors: 102, 136, 156C, 157C, 166A, 166B, 227, 230, 235, 243, 248
1 Lockset 3880 SECT ARC SFIC US26D HA
1 Cylinder Core 3982-C US26D HA
1 Closer 5100 ALM HA
1 Protection Plate 194S 10" x 34" CSK US32D HA
1 Wall Stop 232W US32D HA
SET #4
Doors: 103, 104, 105
1 Cylinder Core 3982-C US26D HA
1 Closer 5100 ALM HA
SET #5
Doors: 106A, 106B, 107, 108, 236A, 236B
3 Hinge BB1279 4 1/2 x 4 1/2 NRP US26D HA
1 Exit Device 4501 RIM 36" CD US26D HA
1 Exit Device Trim 45CE ARC US26D HA
2 Cylinder Core 3982-C US26D HA
2 Mortise Cylinder Housing 3902 IC 1 5/8" US26D HA
1 Closer 5100 ALM HA
1 Protection Plate 194S 10" x 34" CSK US32D HA
SET #6
Doors: 109, 126, 151, 159, 225
1 Cylinder Core 3982-C US26D HA
1 Overhead Stop 7016 SRF SZ1 US32D HA
3 Door Silencer 307D GREY HA
SET #7
Doors: 111, 135A
DOOR HARDWARE 087100 - 20
1 Lockset 3870 SECT ARC SFIC US26D HA
1 Cylinder Core 3982-C US26D HA
1 Closer 5100 TRK NHOTA ALM HA
1 Protection Plate 194S 10" x 34" CSK US32D HA
SET #8
Doors: 112, 113, 114, 116, 120, 122, 123, 124, 137A, 201, 202, 203, 204, 205, 206, 207, 208, 209, 210, 211, 212, 214, 216, 217, 218, 219B, 220, 221, 223, 242
1 Lockset 3850 SECT ARC SFIC US26D HA
1 Cylinder Core 3982-C US26D HA
1 Wall Stop 236W US32D HA
1 Coat Hook 940P 3 1/2 US26D HA
SET #9
Doors: 115, 121, 146, 150, 155, 156B, 157B, 213A, 213B, 219A, 222, 231, 234, 245
1 Cylinder Core 3982-C US26D HA
1 Closer 5100 ALM HA
1 Protection Plate 194S 10" x 34" CSK US32D HA
SET #10
Doors: 117
1 Continuous Hinge 780-112HD 83" ROUND BACK COVER CLR HA
1 Deadlock MS1850S 628 AD
2 Cylinder Core 3982-C US26D HA
2 Mortise Cylinder Housing 3902 IC 1 5/8" 3972 CAM US26D HA
1 Push/Pull Set 160D US32D HA
1 Closer 5100 ALM HA
1 Wall Stop 232W US32D HA
1 Drop Plate 5109 ALM HA
1 Threshold 417S 36" MIL HA
SET #11
Doors: 118A
DOOR HARDWARE 087100 - 21
1 Continuous Hinge 780-112HD 83" RETW10 ROUND BACK COVER CLR HA
1 Exit Device QEL 33A-L x NL x 360-L 07 US26D VO
1 Exit Device 33A-EO US26D VO
1 Rim Cylinder Housing 3901 IC US26D HA
2 Cylinder Core 3982-C US26D HA
1 Mortise Cylinder Housing 3902 IC 1 5/8" US26D HA
1 Power Supply PS914 CVO
2 Magnetic Switch 2-679-0626 HA
1 Removable Mullion 4900T 7' USP HA
1 Threshold 417S 72" MIL HA
2 Mullion Stabilizer 4953 US32D HA
NOTE: AUTO DOOR OPERATOR - SEE SECTION 087113 DOOR BOTTOM,
WEATHERSTRIP BY DOOR SUPPLIER
Description of operation:
Door is normally closed and secure, entry by key leaves lever in locked position
Door relocks upon closing
Free egress all times
Door remains closed and locked upon power failure or fire alarm activation (fail secure)
SET #12
Doors: 118B
2 Continuous Hinge 780-112HD 83" ROUND BACK COVER CLR HA
1 Exit Device 33A-EO US26D VO
2 Exit Device 33A-L x 360-L x NL US26D VO
2 Rim Cylinder Housing 3901 IC US26D HA
2 Cylinder Core 3982-C US26D HA
1 Mortise Cylinder Housing 3902 IC 1 5/8" US26D HA
2 Closer 5100 5955-HDCS ALM HA
2 Drop Plate 5110 ALM HA
2 Blade Stop Spacer 5113 ALM HA
1 Removable Mullion 4900T 7' USP HA
NOTE: DOOR BOTTOM, WEATHERSTRIP BY DOOR SUPPLIER
SET #13
NOTE: NOT USED
SET #14
Doors: 118C
1 Continuous Hinge 780-112HD 83" RETW10 ROUND BACK COVER CLR HA
1 Exit Device QEL 33A-L x NL x 360-L 07 US26D VO
DOOR HARDWARE 087100 - 22
1 Rim Cylinder Housing 3901 IC US26D HA
2 Cylinder Core AS REQUIRED US26D
1 Mortise Cylinder Housing 3902 IC 1 5/8" US26D HA
1 Power Supply PS914 CVO
2 Magnetic Switch 2-679-0626 HA
1 Removable Mullion 4900T 7' USP HA
1 Threshold 520S V 72" MIL HA
1 Mullion Stabilizer 4953 US32D HA
NOTE: DOOR BOTTOM, WEATHERSTRIP BY DOOR SUPPLIER. AUTO DOOR OPERATOR -
SEE SECTION 087113
Card Reader by Security Contractor
Description of operation:
Door is normally closed and secure, entry by key leaves lever in locked position
Upon proper credential validation, entry is permitted
Door relocks upon closing
Free egress all times
Door remains closed and locked upon power failure or fire alarm activation (fail secure)
SET #15
Doors: 118D
2 Continuous Hinge 780-112HD 83" ROUND BACK COVER CLR HA
1 Exit Device 33A-L x 360-L x NL US26D VO
1 Rim Cylinder Housing 3901 IC US26D HA
2 Cylinder Core AS REQUIRED US26D
1 Mortise Cylinder Housing 3902 IC 1 5/8" US26D HA
2 Closer 5100 5955-HDCS ALM HA
2 Drop Plate 5110 ALM HA
2 Blade Stop Spacer 5113 ALM HA
1 Removable Mullion 4900T 7' USP HA
NOTE: DOOR BOTTOM, WEATHERSTRIP BY DOOR SUPPLIER
SET #16
Doors: 125, 237, 238, 239, 240, 241
6 Hinge BB1279 4 1/2 x 4 1/2 NRP US26D HA
2 Flush Bolt 282D US26D HA
1 Lockset 3880 SECT ARC SFIC US26D HA
1 Cylinder Core 3982-C US26D HA
2 Overhead Stop 7016 SRF SZ1 US32D HA
1 Dust Proof Strike 280X US26D HA
1 Set Weatherstripping 726 27' CH HA
1 Astragal 835S 84" USP HA
DOOR HARDWARE 087100 - 23
SET #17
Doors: 127, 132E
NOTE: HARDWARE BY DOOR SUPPLIER
SET #18
Doors: 128A, 128B
1 Cylinder Core 3982-C US26D HA
1 Closer 5100 HD ALM HA
1 Protection Plate 194S 10" x 34" CSK US32D HA
2 Wall Holder 327W US26D HA
SET #19
Doors: 131
1 Privacy Set 3896 ARC US26D HA
1 Closer 5100 ALM HA
1 Protection Plate 194S 10" x 34" CSK US32D HA
1 Protection Plate 194S 4" x 35" CSK US32D HA
1 Wall Stop 236W US32D HA
SET #20
Doors: 132C, 132D, 147B, 147C
2 Exit Device 4501 RIM F 36" US26D HA
1 Exit Device Trim 45CE ARC US26D HA
1 Rim Cylinder Housing 3901 IC US26D HA
2 Cylinder Core 3982-C US26D HA
1 Mortise Cylinder Housing 3902 IC 1 5/8" US26D HA
2 Closer 5100 5955-HDCS ALM HA
1 Removable Mullion 4900T F 7' USP HA
2 Set Weatherstrip 726 17' S HA
SET #21
DOOR HARDWARE 087100 - 24
Doors: 133C
1 Cylinder Core 3982-C US26D HA
1 Closer 5100 ALM HA
1 Wall Stop 232W US32D HA
1 Set Weatherstrip 726 17' S HA
1 Door Sweep 750S N 36" CLR HA
1 Threshold 417S 36" MIL HA
SET #22
Doors: 135B, 135C, 135D, 137B, 137C, 247
NOTE: HARDWARE BY WINDOW SUPPLIER
SET #23
Doors: 138
2 Exit Device 4501 RIM 36" CD US26D HA
1 Exit Device Trim 45NL ARC US26D HA
2 Rim Cylinder Housing 3901 IC US26D HA
3 Cylinder Core 3982-C US26D HA
2 Mortise Cylinder Housing 3902 IC 1 5/8" US26D HA
2 Closer 5100 ALM HA
2 Electromagnetic Door Holder 380F 12/24 LS HA
1 Removable Mullion 4900T 7' USP HA
SET #24
Doors: 139
NOTE: HARDWARE BY VAULT SUPPLIER
SET #25
Doors: 140B, 141B
1 Exit Device Trim 45NL ARC US26D HA
2 Rim Cylinder Housing 3901 IC US26D HA
2 Cylinder Core 3982-C US26D HA
1 Mortise Cylinder Housing 3902 IC 1 5/8" US26D HA
2 Closer 5100 5955-HDCS ALM HA
1 Removable Mullion 4900T 7' USP HA
DOOR HARDWARE 087100 - 25
2 Door Sweep 750S N 36" CLR HA
SET #26
Doors: 145A
1 Cylinder Core 3982-C US26D HA
SET #27
Doors: 145B
1 Cylinder Core 3982-C US26D HA
1 Closer 5100 TRK NHOTA ALM HA
1 Protection Plate 194S 10" x 34" CSK US32D HA
SET #28
Doors: 148
1 Exit Device Trim 45CE ARC US26D HA
1 Rim Cylinder Housing 3901 IC US26D HA
2 Cylinder Core 3982-C US26D HA
2 Mortise Cylinder Housing 3902 IC 1 5/8" US26D HA
2 Closer 5100 5955-HDCS ALM HA
1 Removable Mullion 4900T 7' USP HA
SET #29
Doors: 149, 232, 233
1 Cylinder Core 3982-C US26D HA
SET #30
DOOR HARDWARE 087100 - 26
Doors: 215A, 215B
1 Exit Device 4501 RIM 36" CD US26D HA
1 Exit Device Trim 45CE ARC US26D HA
1 Cylinder Core 3982-C US26D HA
2 Mortise Cylinder Housing 3902 IC 1 5/8" US26D HA
SET #31
Doors: 224, 226
1 Passage Set 3810 SECT ARC US26D HA
1 Closer 5100 ALM HA
1 Protection Plate 194S 10" x 34" CSK US32D HA
SET #32
Doors: 228, 229
3 Hinge BB1168 4 1/2 X 4 1/2 US26D HA
1 Push Plate 30S 6 X 16 US32D HA
1 Door Pull H 33J 4 X 16 US32D HA
1 Closer 5100 ALM HA
1 Protection Plate 194S 10" x 34" CSK US32D HA
1 Protection Plate 194S 4" x 35" CSK US32D HA
SET #33
Doors: 244
1 Passage Set 3810 SECT ARC US26D HA
1 Protection Plate 194S 10" x 34" CSK US32D HA
SET #34:
Doors: 130, 133A, 133E, 144
1 Lockset 3880 SECT ARC SFIC7 US26D HA
DOOR HARDWARE 087100 - 27
1 Cylinder Core 3982-C US26D HA
1 Drip Cap 810S x LAR MIL HA
1 Set Weatherstrip 881S N x LAR MIL HA
1 Threshold 520S V 36” MIL HA
SET #35:
Doors: 132A, 132B, 134, 140A, 141A, 142, 143A, 147A
2 Exit Device 4501 RIM F 36” US26D HA
1 Exit Device Trim 45NL ARC US26D HA
1 Rim Cylinder Housing 3901 SFIC US26D HA
1 Cylinder Core 3982-C US26D HA
2 Closer 5100 5955-HDCS ALM HA
1 Set Weatherstrip 881S N x LAR MIL HA
1 Drip Cap 810S x LAR MIL HA
2 Mullion Seal 710S x LAR CH HA
2 Door Bottom 770S V x LAR MIL HA
2 Threshold 520S V 72” MIL HA
NOTE: Hinges removable mullion by Door Supplier
SET #36:
Doors: 156A, 157A, 158A
1 Exit Device 4501 RIM F 36” US26D HA
1 Exit Device Trim 45NL ARC US26D HA
1 Rim Cylinder Housing 3901 SFIC US26D HA
1 Cylinder Core 3982-C US26D HA
1 Closer 5100 5955-HDCS ALM HA
1 Set Weatherstrip 881S N x LAR MIL HA
1 Drip Cap 810S x LAR MIL HA
1 Threshold 520S V 36” MIL HA
SET #37:
DOOR HARDWARE 087100 - 28
Doors: 158A
2 Exit Device 4501 RIM 36” US26D HA
1 Exit Device Trim 45CE ARC ET EU US26D HA
1 Cylinder Core 3982-C US26D HA
1 Mortise Cylinder Housing 3902 SFIC 1 5/8” US26D HA
2 Closer 5100 5955-HDCS ALM HA
1 Power Supply 2908 HA
1 Access Control Module 2-679-0704 HA
1 Power Transfer 2-679-0624 DBZ HA
1 Set Weatherstrip 881S N x LAR MIL HA
2 Drip Cap 810S x LAR MIL HA
2 Door Bottom 770S V x LAR MIL HA
2 Door Sweep 756S V 84” MIL HA
1 Threshold 520S V 72” MIL HA
NOTE: Hinges, Removable Mullion by Door Supplier. Card Reader by Security
Contractor
SET #38:
Doors: 133B, 133D
NOTE: Hardware by Overhead Door Supplier
END OF SECTION 087100
File details come from the government source that posted it. Updated .