083313_fl_-_coiling_counter_doors.doc.pdf
PDF 47 KB Posted
- Attached to
- Wilmington Readiness Center Federal contract opportunity
- Solicitation number
- W91242-17-B-0005
About this file
083313 Updated
View the file
Other files for this federal contract opportunity
Show all 40
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
National Guard Readiness Center Wilmington, North Carolina Addendum 1 16 August 2017
SECTION 083313 - COILING COUNTER DOORS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Counter doors.
B. Related Requirements:
1. Section 055000 "Metal Fabrications" for door-opening framing and corner guards.
1.3 ACTION SUBMITTALS
A. Product Data: For each type and size of coiling counter door and accessory.
1. Include construction details, material descriptions, dimensions of individual components, profiles for slats, and finishes.
2. Include rated capacities, operating characteristics, electrical characteristics, and furnished accessories.
3. Include description of automatic closing device and testing and resetting instructions.
B. Shop Drawings: For each installation and for special components not dimensioned or detailed in manufacturer's product data.
1. Include plans, elevations, sections, and mounting details.
2. Include details of equipment assemblies, and indicate dimensions, required clearances, method of field assembly, components, and location and size of each field connection.
3. Include points of attachment and their corresponding static and dynamic loads imposed on structure.
4. Show locations of controls, locking devices and other accessories.
C. Samples for Verification: For each type of exposed finish on the following components, in manufacturer's standard sizes:
COILING COUNTER DOORS 083313 - 1
1. Bottom bar.
2. Guides.
3. Brackets.
4. Hood.
5. Locking device(s).
1.4 INFORMATIONAL SUBMITTALS
A. Qualification Data: For Installer.
1.5 CLOSEOUT SUBMITTALS
A. Maintenance Data: For coiling counter doors to include in maintenance manuals.
1.6 QUALITY ASSURANCE
A. Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer for both installation and maintenance of units required for this Project.
1. Maintenance Proximity: Not more than two hours' normal travel time from Installer's place of business to Project site.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Source Limitations: Obtain coiling counter doors from single source from single manufacturer.
1. Obtain operators and controls from coiling counter door manufacturer.
2.2 COUNTER DOOR ASSEMBLY
A. Counter Door: Coiling counter door formed with curtain of interlocking metal slats.
B. Operation Cycles: Door components and operators capable of operating for not less than 50,00020,000. One operation cycle is complete when a door is opened from the closed position to the fully open position and returned to the closed position.
1. Include tamperproof cycle counter.
C. Door Curtain Material: Stainless steel.
COILING COUNTER DOORS 083313 - 2
D. Bottom Bar: Manufacturer's standard continuous channel or tubular shape, fabricated stainless steel or aluminum extrusion and finished to match door.
E. Curtain Jamb Guides: Stainless steel with exposed finish matching curtain slats. Provide continuous integral wear strips to prevent metal-to-metal contact and to minimize operational noise.
F. Hood: Stainless steel.
1. Shape: Round.
2. Mounting: Face of wall.
G. Sill Configuration: No sill.
H. Locking Devices: Equip door with slide bolt for padlock.
1. Locking Device Assembly: Cremone-type, both jamb sides.
I. Manual Door Operator: Push-up operation.
1. Provide operator with manufacturer's standard removable operating arm.
J. Door Finish:
1. Stainless-Steel Finish: No. 4 (polished directional satin).
2. Interior Curtain-Slat Facing: Match finish of exterior curtain-slat face.
2.3 DOOR CURTAIN MATERIALS AND CONSTRUCTION
A. Door Curtains: Fabricate coiling counter door curtain of interlocking metal slats in a continuous length for width of door without splices. Unless otherwise indicated, provide slats of thickness and mechanical properties recommended by door manufacturer for performance, size, and type of door indicated, and as follows:
1. Stainless-Steel Door Curtain Slats: ASTM A 666, Type 304; sheet thickness of
0.025 inch (0.64 mm); and as required.
2. Metal Interior Curtain-Slat Facing: Match metal of exterior curtain-slat face.
B. Curtain Jamb Guides: Manufacturer's standard angles or channels and angles of same material and finish as curtain slats unless otherwise indicated, with sufficient depth and strength to retain curtain, to allow curtain to operate smoothly, and to withstand loading. Slot bolt holes for guide adjustment. Provide removable stops on guides to prevent overtravel of curtain.
COILING COUNTER DOORS 083313 - 3
Addendum 1 16 August 2017
2.4 HOODS
A. General: Form sheet metal hood to entirely enclose coiled curtain and operating mechanism at opening head. Contour to fit end brackets to which hood is attached.
Roll and reinforce top and bottom edges for stiffness. Form closed ends for surface-mounted hoods and fascia for any portion of between-jamb mounting that projects beyond wall face. Equip hood with intermediate support brackets as required to prevent sagging.
1. Stainless Steel: 0.025-inch- (0.64-mm-) thick, stainless-steel sheet, Type 304, complying with ASTM A 666.
B. Integral Frame, Hood, and Fascia: Welded sheet metal assembly of the following sheet metal(s):
1. Stainless Steel: Type 304, complying with ASTM A 666.
2.5 LOCKING DEVICES
A. Slide Bolt: Fabricate with side-locking bolts to engage through slots in tracks for locking by padlock, located on both left and right jamb sides, operable from coil side.
2.6 CURTAIN ACCESSORIES
A. Astragal: Equip each door bottom bar with a replaceable, adjustable, continuous, compressible gasket of flexible vinyl, rubber, or neoprene as a cushion bumper.
B. Pull-Down Strap: Provide pull-down straps for doors more than 84 inches (2130 mm) high.
2.7 COUNTERBALANCE MECHANISM
A. General: Counterbalance doors by means of manufacturer's standard mechanism with an adjustable-tension, steel helical torsion spring mounted around a steel shaft and contained in a spring barrel connected to top of curtain with barrel rings. Use grease-sealed bearings or self-lubricating graphite bearings for rotating members.
B. Counterbalance Barrel: Fabricate spring barrel of manufacturer's standard hot-formed, structural-quality, seamless or welded carbon-steel pipe, of sufficient diameter and wall thickness to support rolled-up curtain without distortion of slats and to limit barrel deflection to not more than 0.03 in./ft. (2.5 mm/m) of span under full load.
C. Counterbalance Spring: One or more oil-tempered, heat-treated steel helical torsion springs. Size springs to counterbalance weight of curtain, with uniform adjustment accessible from outside barrel. Secure ends of springs to barrel and shaft with cast-steel barrel plugs.
COILING COUNTER DOORS 083313 - 4
D. Torsion Rod for Counterbalance Shaft: Fabricate of manufacturer's standard cold-rolled steel, sized to hold fixed spring ends and carry torsional load.
E. Brackets: Manufacturer's standard mounting brackets of either cast iron or cold-rolled steel plate.
2.8 MANUAL DOOR OPERATORS
A. General: Equip door with manual door operator by door manufacturer.
B.A. Push-up Door Operation: Design counterbalance mechanism so that required lift or pull for door operation does not exceed 25 lbf (111 N).
2.9 GENERAL FINISH REQUIREMENTS
A. Comply with NAAMM/NOMMA 500 for recommendations for applying and designating finishes.
B. Appearance of Finished Work: Noticeable variations in same piece are not acceptable.
Variations in appearance of adjoining components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast.
2.10 STAINLESS-STEEL FINISHES
A. Surface Preparation: Remove tool and die marks and stretch lines, or blend into finish.
B. Polished Finishes: Grind and polish surfaces to produce uniform finish, free of cross scratches.
1. Run grain of directional finishes with long dimension of each piece.
2. When polishing is completed, passivate and rinse surfaces. Remove embedded foreign matter and leave surfaces chemically clean.
3. Directional Satin Finish: No. 4.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates areas and conditions, with Installer present, for compliance with requirements for substrate construction and other conditions affecting performance of the Work.
B. Examine locations of electrical connections.
C. Proceed with installation only after unsatisfactory conditions have been corrected.
COILING COUNTER DOORS 083313 - 5
Addendum 1 16 August 2017
3.2 INSTALLATION
A. Install coiling counter doors and operating equipment complete with necessary hardware, anchors, inserts, hangers, and equipment supports; according to manufacturer's written instructions and as specified.
B. Install coiling counter doors, hoods, controls, and operators at the mounting locations indicated for each door.
3.3 STARTUP SERVICE
A. Engage a factory-authorized service representative to perform startup service.
1. Complete installation and startup checks according to manufacturer's written instructions.
2. Test and adjust controls and safety devices. Replace damaged and malfunctioning controls and equipment.
3. Test door closing when activated by detector or alarm-connected fire-release system. Reset door-closing mechanism after successful test.
3.4 ADJUSTING
A. Adjust hardware and moving parts to function smoothly so that doors operate easily, free of warp, twist, or distortion.
B. Lubricate bearings and sliding parts as recommended by manufacturer.
C. Adjust seals to provide tight fit around entire perimeter.
3.5 MAINTENANCE SERVICE
A. Initial Maintenance Service: Beginning at Substantial Completion, maintenance service shall include 12 months' full maintenance by skilled employees of coiling-door Installer.
Include quarterly preventive maintenance, repair or replacement of worn or defective components, lubrication, cleaning, and adjusting as required for proper door operation.
Parts and supplies shall be manufacturer's authorized replacement parts and supplies.
1. Perform maintenance, including emergency callback service, during normal working hours.
2. Include 24-hour-per-day, seven-day-per-week, emergency callback service.
3.6 DEMONSTRATION
A. Engage a factory-authorized service representative to train Owner's maintenance personnel to adjust, operate, and maintain coiling counter doors.
COILING COUNTER DOORS 083313 - 6
Addendum 1 16 August 2017
END OF SECTION 083313
COILING COUNTER DOORS 083313 - 7
| PART 1 - GENERAL |
| 1.1 RELATED DOCUMENTS |
| A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. |
| 1.2 SUMMARY |
| A. Section Includes: |
| 1. Counter doors. |
| B. Related Requirements: |
| 1. Section 055000 "Metal Fabrications" for door-opening framing and corner guards. |
| 1.3 ACTION SUBMITTALS |
| A. Product Data: For each type and size of coiling counter door and accessory. |
| 1. Include construction details, material descriptions, dimensions of individual components, profiles for slats, and finishes. |
| 2. Include rated capacities, operating characteristics, electrical characteristics, and furnished accessories. |
| 3. Include description of automatic closing device and testing and resetting instructions. |
| B. Shop Drawings: For each installation and for special components not dimensioned or detailed in manufacturer's product data. |
| 1. Include plans, elevations, sections, and mounting details. |
| 2. Include details of equipment assemblies, and indicate dimensions, required clearances, method of field assembly, components, and location and size of each field connection. |
| 3. Include points of attachment and their corresponding static and dynamic loads imposed on structure. |
| 4. Show locations of controls, locking devices and other accessories. |
| C. Samples for Verification: For each type of exposed finish on the following components, in manufacturer's standard sizes: |
| 1. Bottom bar. |
| 2. Guides. |
| 3. Brackets. |
| 4. Hood. |
| 5. Locking device(s). |
| 1.4 INFORMATIONAL SUBMITTALS |
| A. Qualification Data: For Installer. |
| 1.5 CLOSEOUT SUBMITTALS |
| A. Maintenance Data: For coiling counter doors to include in maintenance manuals. |
| 1.6 QUALITY ASSURANCE |
| A. Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer for both installation and maintenance of units required for this Project. |
| 1. Maintenance Proximity: Not more than two hours' normal travel time from Installer's place of business to Project site. |
| PART 2 - PRODUCTS |
| 2.1 MANUFACTURERS |
| A. Source Limitations: Obtain coiling counter doors from single source from single manufacturer. |
| 1. Obtain operators and controls from coiling counter door manufacturer. |
| 2.2 COUNTER DOOR ASSEMBLY |
| A. Counter Door: Coiling counter door formed with curtain of interlocking metal slats. |
| B. Operation Cycles: Door components and operators capable of operating for not less than 50,00020,000. One operation cycle is complete when a door is opened from the closed position to the fully open position and returned to the closed position. |
| 1. Include tamperproof cycle counter. |
| C. Door Curtain Material: Stainless steel. |
| D. Bottom Bar: Manufacturer's standard continuous channel or tubular shape, fabricated stainless steel or aluminum extrusion and finished to match door. |
| E. Curtain Jamb Guides: Stainless steel with exposed finish matching curtain slats. Provide continuous integral wear strips to prevent metal-to-metal contact and to minimize operational noise. |
| F. Hood: Stainless steel. |
| 1. Shape: Round. |
| 2. Mounting: Face of wall. |
| G. Sill Configuration: No sill. |
| H. Locking Devices: Equip door with slide bolt for padlock. |
| 1. Locking Device Assembly: Cremone-type, both jamb sides. |
| I. Manual Door Operator: Push-up operation. |
| 1. Provide operator with manufacturer's standard removable operating arm. |
| J. Door Finish: |
| 1. Stainless-Steel Finish: No. 4 (polished directional satin). |
| 2. Interior Curtain-Slat Facing: Match finish of exterior curtain-slat face. |
| 2.3 DOOR CURTAIN MATERIALS AND CONSTRUCTION |
| A. Door Curtains: Fabricate coiling counter door curtain of interlocking metal slats in a continuous length for width of door without splices. Unless otherwise indicated, provide slats of thickness and mechanical properties recommended by door manufac... |
| 1. Stainless-Steel Door Curtain Slats: ASTM A 666, Type 304; sheet thickness of 34T0.025 inch34T44T (0.64 mm)44T; and as required. |
| 2. Metal Interior Curtain-Slat Facing: Match metal of exterior curtain-slat face. |
B. Curtain Jamb Guides: Manufacturer's standard angles or channels and angles of same material and finish as curtain slats unless otherwise indicated, with sufficient depth and strength to retain curtain, to allow curtain to operate smoothly, and to w...
| 2.4 HOODS |
| A. General: Form sheet metal hood to entirely enclose coiled curtain and operating mechanism at opening head. Contour to fit end brackets to which hood is attached. Roll and reinforce top and bottom edges for stiffness. Form closed ends for surface-mo... |
| 1. Stainless Steel: 34T0.025-inch-34T44T (0.64-mm-)44T thick, stainless-steel sheet, Type 304, complying with ASTM A 666. |
| B. Integral Frame, Hood, and Fascia: Welded sheet metal assembly of the following sheet metal(s): |
| 1. Stainless Steel: Type 304, complying with ASTM A 666. |
| 2.5 LOCKING DEVICES |
| A. Slide Bolt: Fabricate with side-locking bolts to engage through slots in tracks for locking by padlock, located on both left and right jamb sides, operable from coil side. |
| 2.6 CURTAIN ACCESSORIES |
| A. Astragal: Equip each door bottom bar with a replaceable, adjustable, continuous, compressible gasket of flexible vinyl, rubber, or neoprene as a cushion bumper. |
| B. Pull-Down Strap: Provide pull-down straps for doors more than 34T84 inches34T44T (2130 mm)44T high. |
| 2.7 COUNTERBALANCE MECHANISM |
| A. General: Counterbalance doors by means of manufacturer's standard mechanism with an adjustable-tension, steel helical torsion spring mounted around a steel shaft and contained in a spring barrel connected to top of curtain with barrel rings. Use gr... |
| B. Counterbalance Barrel: Fabricate spring barrel of manufacturer's standard hot-formed, structural-quality, seamless or welded carbon-steel pipe, of sufficient diameter and wall thickness to support rolled-up curtain without distortion of slats and t... |
| C. Counterbalance Spring: One or more oil-tempered, heat-treated steel helical torsion springs. Size springs to counterbalance weight of curtain, with uniform adjustment accessible from outside barrel. Secure ends of springs to barrel and shaft with c... |
| D. Torsion Rod for Counterbalance Shaft: Fabricate of manufacturer's standard cold-rolled steel, sized to hold fixed spring ends and carry torsional load. |
| E. Brackets: Manufacturer's standard mounting brackets of either cast iron or cold-rolled steel plate. |
| 2.8 MANUAL DOOR OPERATORS |
| A. General: Equip door with manual door operator by door manufacturer. |
| A. Push-up Door Operation: Design counterbalance mechanism so that required lift or pull for door operation does not exceed 34T25 lbf34T44T (111 N)44T. |
| 2.9 GENERAL FINISH REQUIREMENTS |
| A. Comply with NAAMM/NOMMA 500 for recommendations for applying and designating finishes. |
| B. Appearance of Finished Work: Noticeable variations in same piece are not acceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast. |
| 2.10 STAINLESS-STEEL FINISHES |
| A. Surface Preparation: Remove tool and die marks and stretch lines, or blend into finish. |
| B. Polished Finishes: Grind and polish surfaces to produce uniform finish, free of cross scratches. |
| 1. Run grain of directional finishes with long dimension of each piece. |
| 2. When polishing is completed, passivate and rinse surfaces. Remove embedded foreign matter and leave surfaces chemically clean. |
| 3. Directional Satin Finish: No. 4. |
| PART 3 - EXECUTION |
| 3.1 EXAMINATION |
| A. Examine substrates areas and conditions, with Installer present, for compliance with requirements for substrate construction and other conditions affecting performance of the Work. |
| B. Examine locations of electrical connections. |
| C. Proceed with installation only after unsatisfactory conditions have been corrected. |
| 3.2 INSTALLATION |
| A. Install coiling counter doors and operating equipment complete with necessary hardware, anchors, inserts, hangers, and equipment supports; according to manufacturer's written instructions and as specified. |
| B. Install coiling counter doors, hoods, controls, and operators at the mounting locations indicated for each door. |
| 3.3 STARTUP SERVICE |
| A. Engage a factory-authorized service representative to perform startup service. |
| 1. Complete installation and startup checks according to manufacturer's written instructions. |
| 2. Test and adjust controls and safety devices. Replace damaged and malfunctioning controls and equipment. |
| 1. Test door closing when activated by detector or alarm-connected fire-release system. Reset door-closing mechanism after successful test. |
| 3.4 ADJUSTING |
| A. Adjust hardware and moving parts to function smoothly so that doors operate easily, free of warp, twist, or distortion. |
| B. Lubricate bearings and sliding parts as recommended by manufacturer. |
| A. Adjust seals to provide tight fit around entire perimeter. |
| 3.5 MAINTENANCE SERVICE |
| A. Initial Maintenance Service: Beginning at Substantial Completion, maintenance service shall include 12 months' full maintenance by skilled employees of coiling-door Installer. Include quarterly preventive maintenance, repair or replacement of worn ... |
| 1. Perform maintenance, including emergency callback service, during normal working hours. |
| 2. Include 24-hour-per-day, seven-day-per-week, emergency callback service. |
| 3.6 DEMONSTRATION |
| A. Engage a factory-authorized service representative to train Owner's maintenance personnel to adjust, operate, and maintain coiling counter doors. |