Attch 9 AD102.pdf

PDF 478 KB Posted

Attached to
DLA Building 54 Navy Artifact Restoration Federal contract opportunity
Solicitation number
W9123622B2041
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This document includes floor plans and demolition details for Building 54 at the Navy Artifact Restoration facility in Richmond, Virginia. The project involves removing existing walls, doors, flooring, and other items to prepare for HVAC system upgrades in various rooms. Demolition notes specify removal and disposal procedures for different building elements. The related federal contract opportunity is solicitation number W91236-22-B-2041 issued by the Department of the Army Corps of Engineers Norfolk District for HVAC work at Building 54 to support restoration of Navy artifacts. The solicitation was posted on December 7th.

View the file

Other files for this federal contract opportunity

Other files attached to DLA Building 54 Navy Artifact Restoration, newest first.
File Type Posted
B.01.02_22B2041 Abstract of Offers.pdf PDF
Attch 27 01 45 04.00 50.pdf PDF
W9123622B2041 Amendment 0011.pdf PDF
Amendment 10 Final.pdf PDF
Amendment 9 Final.pdf PDF
W9123622D2041 Amendment 0008.pdf PDF
W9123622B2041 Amendment 0006.pdf PDF
Attch 26 EL101.pdf PDF
Attch 23 M602.pdf PDF
Attch 17 FA101.pdf PDF
Attch 10 AD111.pdf PDF
Attch 5 01 50 02 00 50.pdf PDF
Attch 1 Project Table of Contents 00 00 00.pdf PDF
Attch 22 M601.pdf PDF
Attch 19 MH101.pdf PDF
Attch 16 A601.pdf PDF
Attch 15 A301.pdf PDF
Attch 14 A112.pdf PDF
Attch 11 AD112.pdf PDF
Attch 6 03 30 53.pdf PDF
Attch 21 MP101.pdf PDF
Attch 18 MD101.pdf PDF
Attch 13 A111.pdf PDF
Attch 8 AD101.pdf PDF
Attch 7 08 33 23.pdf PDF
22B2041 Amendment 0006.pdf PDF
Attch 25 M805.pdf PDF
Attch 20 MH111.pdf PDF
Attch 12 AD122.pdf PDF
Attch 4 01 45 35.pdf PDF
Attch 3 01 45 35 SI Schedule - 1-28-2022.pdf PDF
Attch 2 01 45 35 Statement of Special Inspections - 1 28 2022.pdf PDF
Attch 24 M801.pdf PDF
W9123622B2041 Amendment 0005.pdf PDF
22B2041 B54 HVAC Amendment 4.pdf PDF
19 Jan Site visit.pdf PDF
Amendment 0003 Final.pdf PDF
Amendment 0002 Final.pdf PDF
Site Visit 5 January.pdf PDF
Amendment 0001 Final.pdf PDF
A.01.13_0455737 NAO663A B54-HVAC-ARTIFACT-IFB-DRAWINGS.pdf PDF
A.01.13_0455737 NAO663A B54-ARTIFACT-SPECS.pdf PDF
W9123622B2041 IFB.pdf PDF
Show all 43

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FD

26 27 28 29 30

J

K

'-0

VE

R

IF

Y)

2'-0" 39'-0" 40'-0" 40'-0" 43'-0"

M

AT

C H

LI

N

E

E1 /A

D

22 3 3

CONSERVATION

LAB

HIGH DENSITY

COMPACT

STORAGE

WOMEN'S

MEN'S

DELTA ROOM

LAUNDRY

CONSERVATION

LAB

JANITOR

NHHC STORAGE

111B111D 111C

122A

PHOTO 3

PHOTO 4

PHOTO 5

4' -8

- H

IG

H

'-0

1' -0

- H

IG

H

'-0

4' -8

-H

IG

H

'-0

4'-8" +- HIGH

15'-4" 80'-6" +-(6'-0"+- HIGH)

4'-8"+- HIGH

15'-3"33

PHOTO 6

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

P S

O F

EN

G

IN

E

ER

S

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

, N

O R

FO

LK

, V A, D

R

AW

N B

Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

A C

T N

O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P

N

M

L

K

J

H

G

F

E

D

C

B

A

SEALGRAPHIC SCALES

KEYPLAN

ARTIFACTS

A B

N

AO

F

IL

E N

O

3A

AD102

FL

O

O R

P

LA

N

D

EM

O

LI

TI

O

N

A R

EA

B

BU

IL

D

IN

G

4, JE

FF

ER

SO

N D

AV

IS

H W

Y, R

IC

H

M O

N D

VA

, 2

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

A, K.

O

LT

R . D

U C

H

ES

N E

K.

O

LT

M . D

E

PA

D U

A

O C

TO

B

ER

5, W

G

LG

W

6-

-D

-0

1-

BU

IL

D

IN

G

D

ES

IG

N F

O R

H

VA

C S

YS

TE

M S

IN

N

AV

Y

AR

TI

FA

C

T R

O O

M

SCALE: 1/8" = 1'-0"E1 FLOOR PLAN - DEMOLITION - AREA B

0 4' 8' 16'

SCALE: 1/8" = 1'-0"

PLAN

NORTH

ROOM SQUARE FEET

NO. ROOM NAME AREA

110 DELTA ROOM 569 SF

111 HIGH DENSITY COMPACT STORAGE 5708 SF

122 CORRIDOR 488 SF

123 MECHANICAL ROOM 2683 SF

124 PRACTICE 470 SF

125 RECEIVING 812 SF

126 STORAGE 643 SF

128 JANITOR 75 SF

129 LAUNDRY 73 SF

130 ELECTRICAL ROOM 267 SF

131 CONSERVATION LAB 1075 SF

132 CONSERVATION LAB 295 SF

133 WOMEN'S 134 SF

134 MEN'S 129 SF

# DEMOLITION KEYNOTES

1 REMOVE DOOR AND ALL APPURTENANCES IN

ENTIRETY

2 REMOVE DOOR SYSTEM WHERE REQUIRED

DURING WALL DEMOLITION.

3 REMOVE AND DISPOSE OF ALL GLASS BLOCK

UNITS AND PREPARE OPENING FOR INFILL

4 REMOVE AND DISPOSE OF GYPSUM WALL BOARD

AND FRAMING, PREPARE FOR INSTALLATION OF

AIR BARRIER AND INFILL CONSTRUCTION SYSTEM.

5 REMOVE DOOR SYSTEM WHERE REQUIRED

DURING WALL DEMOLITION. PREPARE DOOR AND

FRAME FOR INSTALLATION OF NEW HARDWARE.

REFERENCE DOOR SCHEDULE

6 FIRE ALARM PULL STATION TO BE DISCONNECTED

AND RETURNED TO OWNER. REF FD DRAWINGS

7 DISCONNECT. REMOVE AND CAP WIRING FOR

DOOR CONTACT DEVICE PRIOR TO REMOVAL OF

WALL AND DOOR

8 REMOVE AND DISPOSE OF EXISTING BRICK SILL.

REFERENCE WALL SECTION FOR EXACT

LOCATION.

9 REMOVE AND DISPOSE OF EXISTING EPOXY WALL

BASE AS REQUIRED. REFERENCE WALL SECTION

FOR EXACT LOCATION

10 THE HIGH DENSITY COMPACT (HDC) STORAGE

UNITS CURRENTLY HOUSED IN THIS SPACE WILL

BE REMOVED AND STORED OFFSITE BY

DSCR/NHHC PRIOR TO THE START OF THIS

CONTRACT.

PHOTO 3 - DOOR 111C PHOTO 4 - DOOR 111B PHOTO 5 - DOOR 111A PHOTO 6 - WALL, CEILING AND BASE EXISTING CONDITION

REMOVE BRICK SILL

FOR INSTALATION OF

NEW GYPSUM WALL

BOARD INFILL SYSTEM

CUT, REMOVE AND

DISPOSE EPOXY

BASE OFF FROM

THE FLOOR FINISH

TRIM OR REPLACE

ACOUSTICAL CEILING

PANEL TO FIT NEW

CEILING PERIMETER GRID

REMOVE AND

DISPOSE

GYPSUM WALL

BOARD AND

FRAMING

REMOVE AND DISPOSE

GYPSUM WALL BOARD AND

FRAMING

REMOVE AND DISPOSE

GYPSUM WALL BOARD AND

FRAMING

AM

EN

D

M

EN

T 0 1

-B

ID

D

ER

IN

Q

U

IR

IE

S

1/

/2

GENERAL NOTES:

1. ANY PORTION OF EXTERIOR WALL NOT COMPLETED BEFORE THE

END OF THE WORK DAY WILL REQUIRE TEMPORARY PROTECTION

TO WEATHERPROOF THE AREA. COORDINATION WITH THE

GOVERNMENT IS REQUIRED OF SECURITY PURPOSES.

Sheets
FA101 - FLOOR PLAN – AREA A - FIRE ALARM
Sheets
MD101 - FLOOR PLAN – AREA A – DEMOLITION
MH101 - FLOOR PLAN – AREA A - DUCTWORK
MH111 - ROOF PLAN - AREA A - DUCTWORK
MP101 - FLOOR PLAN – AREA A - PIPING
M-601 - CHILLED WATER SYSTEM FLOW DIAGRAM
M-602 - SCHEDULES
M-801 - CONTROLS
M-805 - CONTROLS
Sheets
EL101 - FLOOR PLAN – AREA A - LIGHTING

File details come from the government source that posted it. Updated .