Attch 14 A112.pdf

PDF 122 KB Posted

Attached to
DLA Building 54 Navy Artifact Restoration Federal contract opportunity
Solicitation number
W9123622B2041
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This reflected ceiling plan drawing and related solicitation provide details for a federal contract opportunity with the Department of the Army Corps of Engineers Engineering District Norfolk. The solicitation, posted on December 7th, concerns design and restoration work for HVAC systems and artifact storage rooms in Building 54 at a Navy facility. The reflected ceiling plan drawing depicts the layout and dimensions of various rooms in Area B of Building 54, including storage, mechanical, lab, office and restroom spaces. It identifies locations for ceiling tiles, lighting fixtures, sprinklers and other components. The solicitation seeks bids for mechanical, electrical and plumbing work to support HVAC system upgrades and repairs to walls and ceilings damaged during earlier phases of construction. The response deadline is not specified.

View the file

Other files for this federal contract opportunity

Other files attached to DLA Building 54 Navy Artifact Restoration, newest first.
File Type Posted
B.01.02_22B2041 Abstract of Offers.pdf PDF
Attch 27 01 45 04.00 50.pdf PDF
W9123622B2041 Amendment 0011.pdf PDF
Amendment 10 Final.pdf PDF
Amendment 9 Final.pdf PDF
W9123622D2041 Amendment 0008.pdf PDF
W9123622B2041 Amendment 0006.pdf PDF
Attch 21 MP101.pdf PDF
Attch 18 MD101.pdf PDF
Attch 13 A111.pdf PDF
Attch 8 AD101.pdf PDF
Attch 7 08 33 23.pdf PDF
Attch 26 EL101.pdf PDF
Attch 23 M602.pdf PDF
Attch 17 FA101.pdf PDF
Attch 10 AD111.pdf PDF
Attch 5 01 50 02 00 50.pdf PDF
Attch 1 Project Table of Contents 00 00 00.pdf PDF
22B2041 Amendment 0006.pdf PDF
Attch 25 M805.pdf PDF
Attch 20 MH111.pdf PDF
Attch 12 AD122.pdf PDF
Attch 4 01 45 35.pdf PDF
Attch 3 01 45 35 SI Schedule - 1-28-2022.pdf PDF
Attch 2 01 45 35 Statement of Special Inspections - 1 28 2022.pdf PDF
Attch 24 M801.pdf PDF
Attch 22 M601.pdf PDF
Attch 19 MH101.pdf PDF
Attch 16 A601.pdf PDF
Attch 15 A301.pdf PDF
Attch 11 AD112.pdf PDF
Attch 9 AD102.pdf PDF
Attch 6 03 30 53.pdf PDF
W9123622B2041 Amendment 0005.pdf PDF
22B2041 B54 HVAC Amendment 4.pdf PDF
19 Jan Site visit.pdf PDF
Amendment 0003 Final.pdf PDF
Amendment 0002 Final.pdf PDF
Amendment 0001 Final.pdf PDF
Site Visit 5 January.pdf PDF
A.01.13_0455737 NAO663A B54-ARTIFACT-SPECS.pdf PDF
W9123622B2041 IFB.pdf PDF
A.01.13_0455737 NAO663A B54-HVAC-ARTIFACT-IFB-DRAWINGS.pdf PDF
Show all 43

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

26 27 28 29 30

J

K

0"

7'-11"

M

AT

C H

LI

N

E

E1 /A

-1

SD SMOKE DETECTOR (REFER TO FA DWGS)

EXIT SIGN LOCATION (REFER TO FA DWGS)

CEILING HEIGHT, ABOVE FINISH FLOOR2X2 ACT CEILING

SPRINKLER HEAD (REFER TO FX DWGS)

9'-0"

RETURN REGISTER

SUPPLY DIFFUSER

EXHAUST GRILLE

RETURN GRILLE

LINEAR DIFFUSER

LIGHT FIXTURE

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

P S

O F

EN

G

IN

E

ER

S

N O

R

FO

LK

D

IS

TR

IC

T

FR

O

N T

ST

, N

O R

FO

LK

, V A, D

R

AW

N B

Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

A C

T N

O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P

N

M

L

K

J

H

G

F

E

D

C

B

A

SEALGRAPHIC SCALES

KEYPLAN

ARTIFACTS

A B

N

AO

F

IL

E N

O

3A

A-112

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

AR

EA

B

BU

IL

D

IN

G

4, JE

FF

ER

SO

N D

AV

IS

H W

Y, R

IC

H

M O

N D

VA

, 2

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

A, K.

O

LT

R . D

U C

H

ES

N E

K.

O

LT

M . D

E

PA

D U

A

O C

TO

B

ER

5, W

G

LG

W

6-

-D

-0

1-

BU

IL

D

IN

G

D

ES

IG

N F

O R

H

VA

C S

YS

TE

M S

IN

N

AV

Y

AR

TI

FA

C

T R

O O

M

SCALE: 1/8" = 1'-0"E1 REFLECTED CEILING PLAN - AREA B

0 4' 8' 16'

SCALE: 1/8" = 1'-0"

CEILING LEGEND

PLAN

NORTH

ROOM SQUARE FEET

NO. ROOM NAME AREA

110 DELTA ROOM 569 SF

111 HIGH DENSITY COMPACT STORAGE 5708 SF

122 CORRIDOR 488 SF

123 MECHANICAL ROOM 2683 SF

124 PRACTICE 470 SF

125 RECEIVING 812 SF

126 STORAGE 643 SF

128 JANITOR 75 SF

129 LAUNDRY 73 SF

130 ELECTRICAL ROOM 267 SF

131 CONSERVATION LAB 1075 SF

132 CONSERVATION LAB 295 SF

133 WOMEN'S 134 SF

134 MEN'S 129 SF

# KEYNOTES

1 REINSTALL CEILING GRID SYSTEM ONCE MEP & FP WORK

IS COMPLETE. PROVIDE NEW GRID WHERE GRID HAS

BEEN DAMAGED DURING THE COURSE OF WORK.

2 PROVIDE NEW CEILING TILES THROUGHOUT ALL SPACES

WHERE WORK HAS OCCURRED.

3 PATCH AND REPAIR ADJACENT WALL SURFACES THAT

HAVE BEEN DAMAGED DURING THE COURSE OF WORK.

PAINT TO MATCH EXISTING COLORS. EXCEPT THAT ALL

WALLS IN AREAS THAT HAVE SUSPENDED CEILINGS

SHALL BE REPAINTED IN THEIR ENTIRETY WITH PAINT TO

MATCH EXISTING COLOR.

4 PROVIDE AND INSTALL NEW CEILING GRID HANGER. REF

WALL SECTION

SHEET NOTES

1. COORDINATE THE REMOVAL AND REINSTALLATION OF

CEILING MOUNTED ITEMS WITH MEP & FP WORK.

AM

EN

D

M

EN

T 0 1

-B

ID

D

ER

IN

Q

U

IR

IE

S

1/

/2

File details come from the government source that posted it. Updated .