This reflected ceiling plan drawing and keynotes specify the scope of work required to restore ceiling systems in various rooms of Building 54 at the Department of the Army Corps of Engineers Engineering District Norfolk. The work includes reinstalling ceiling grid as needed where damaged by mechanical, electrical, and fire protection work, replacing ceiling tiles throughout areas where work occurred, and repairing and painting adjacent wall surfaces in full where suspended ceilings exist. Coordination is required to remove and reinstall ceiling mounted items with other trades. The related solicitation posting seeks bids for HVAC system design for Navy artifact rooms in Building 54 under solicitation number W91236-22-B-2041, with a response deadline of December 7, 2022. The work is for the Department of the Army Corps of Engineers Engineering District Norfolk.
View the file
Other files for this federal contract opportunity
Show all 43
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
24 25 26 27
J
K
22 23
124 125
126 110
M
AT
C H
LI
N
E
E1 /A
-1
SD SMOKE DETECTOR (REFER TO FA DWGS)
EXIT SIGN LOCATION (REFER TO FA DWGS)
CEILING HEIGHT, ABOVE FINISH FLOOR2X2 ACT CEILING
SPRINKLER HEAD (REFER TO FX DWGS)
9'-0"
RETURN REGISTER
SUPPLY DIFFUSER
EXHAUST GRILLE
RETURN GRILLE
LINEAR DIFFUSER
LIGHT FIXTURE
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
N O
R
FO
LK
D
IS
TR
IC
T
FR
O
N T
ST
, N
O R
FO
LK
, V A, D
R
AW
N B
Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
N
M
L
K
J
H
G
F
E
D
C
B
A
SEALGRAPHIC SCALES
KEYPLAN
ARTIFACTS
A B
N
AO
F
IL
E N
O
3A
A-111
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
AR
EA
A
BU
IL
D
IN
G
4, JE
FF
ER
SO
N D
AV
IS
H W
Y, R
IC
H
M O
N D
VA
, 2
W
SP
BE
N
D
IX
R D
S
TE
VI
R
G
IN
IA
B
EA
C
H , V
A, K.
O
LT
R . D
U C
H
ES
N E
K.
O
LT
M . D
E
PA
D U
A
O C
TO
B
ER
5, W
G
LG
W
6-
-D
-0
1-
BU
IL
D
IN
G
D
ES
IG
N F
O R
H
VA
C S
YS
TE
M S
IN
N
AV
Y
AR
TI
FA
C
T R
O O
M
SCALE: 1/8" = 1'-0"E1 REFLECTED CEILING PLAN - AREA A
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
CEILING LEGEND
PLAN
NORTH
ROOM SQUARE FEET
NO. ROOM NAME AREA
110 DELTA ROOM 569 SF
111 HIGH DENSITY COMPACT STORAGE 5708 SF
122 CORRIDOR 488 SF
123 MECHANICAL ROOM 2683 SF
124 PRACTICE 470 SF
125 RECEIVING 812 SF
126 STORAGE 643 SF
128 JANITOR 75 SF
129 LAUNDRY 73 SF
130 ELECTRICAL ROOM 267 SF
131 CONSERVATION LAB 1075 SF
132 CONSERVATION LAB 295 SF
133 WOMEN'S 134 SF
134 MEN'S 129 SF
# KEYNOTES
1 REINSTALL CEILING GRID SYSTEM ONCE MEP & FP WORK
IS COMPLETE. PROVIDE NEW GRID WHERE GRID HAS
BEEN DAMAGED DURING THE COURSE OF WORK.
2 PROVIDE NEW CEILING TILES THROUGHOUT ALL SPACES
WHERE WORK HAS OCCURRED.
3 PATCH AND REPAIR ADJACENT WALL SURFACES THAT
HAVE BEEN DAMAGED DURING THE COURSE OF WORK.
PAINT TO MATCH EXISTING COLORS. EXCEPT THAT ALL
WALLS IN AREAS THAT HAVE SUSPENDED CEILINGS
SHALL BE REPAINTED IN THEIR ENTIRETY WITH PAINT TO
MATCH EXISTING COLOR.
SHEET NOTES
1. COORDINATE THE REMOVAL AND REINSTALLATION OF
CEILING MOUNTED ITEMS WITH MEP & FP WORK.
AM